Dimensions / Abmessungen - Henkel
Transcrição
Dimensions / Abmessungen - Henkel
• Dimensions / Abmessungen 73 mm 2.9" 2 4 Schematic Diagram Anschlussschema 6 mm 0.24 " 25 mm 1" 210 mm 8.3 " Solenoid Valve Module Ventilinsel 6.5 mm 0.26 " 4.5 mm 0.178 " 1 A 4 B COAX VALVE A STO 1 FE 2 STO 0 4 A B COAX VALVE STO A FE 1 STO 4 FE 2 90 mm 4 " 3.54 " 4 0 4 4 COAX VALVE 4 COAX 1 2 VALVE STO B FE 0 STO 2 FE 0 4 STO FE STO A FE B 4 B 4 4 4 132 mm 5.2 " 102 mm 97204 FE XS12/IN 20 mm 0.79 " + 146 mm 5.75 " 6 mm 0.24 " Pin Connection see Operating Manual Automatic Controller 97103 Steckerbelegung siehe Bedienungsanleitung Automatik-Steuergerät 97103 Henkel Loctite Deutschland GmbH Arabellastraß e 17 Telefon 0 89/92 68-0 D-81925 Mü nchen Telefax 0 89/9 10 19 78 C Henkel Loctite Corporation 2003 1 10 A B 1 4 1 A 11 18 12 17 13 15 A VALVE B COAX STO 4 4 COAX VALVE COAX VALVE STO B FE 1 STO 4 FE FE STO STO B FE A 4 B 4 4 4 4 XS 12/IN 16 14 10 11 12 13 14 15 16 17 18 Exhaust Air Silencer A Connector for Rotor Channel A. A Connector for Proximity Switch Advancing Slide Basic Position Channel A. Connector for Proximity A Switch Advancing Slide extracted Position Channel A. XS 12/IN Connection to Automatic Controller 97103. Operational Check LED’s. 1 2 3 4 Anschluss für Druckluft-Schlauch Außen-Ø 6 mm kalibriert. Anschluss für Schlauch A Außen-Ø 4 kalibriert, Dosierventil geschlossen, Kanal A Anschluss für Schlauch A Außen-Ø 4 kalibriert Dosierventil geöffnet, Kanal A Anschluss für Schlauch A Außen-Ø 4 kalibriert Vorschub eingefahren, Kanal A 5 A Like 13, but Channel B. B B B Like 12, but Channel B. Like 11, but Channel B. 6, 7 B 8, 9 B Anschluss für Schlauch Außen-Ø 4 kalibriert Vorschub ausgefahren, Kanal A Wie 2 und 3, nur Kanal B. 10 11 12 13 14 15 16 17 18 Abluft-Schalldämpfer Anschluss für Rotor A Kanal A. Anschluss für A Zylinderabfrage VorSchubeinheit eingefahren Kanal A. Anschluss für A Zylinderabfrage VorSchubeinheit ausgefahren Kanal A. Anschluss Kabel zu XS 12/IN Universal-Steuergerät 97103. Funktionskontrolle LEDs. B Wie 13, nur Kanal B. B Wie 12, nur Kanal B. B Wie 11, nur Kanal B. Wie 4 und 5, nur Kanal B. Manufacturer’s Declaration The Manufacturer according to the EC regulations Über die Ventilinsel 97204 werden folgende Funktionen realisiert: – pneumatische Steuerung von zwei doppeltwirkenden Vorschubeinheiten A und B; – pneumatische Steuerung von zwei doppeltwirkenden Dosierventilen A und B; – elektrische Steuerung von zwei Rotoreinheiten. A VALVE 4 1 FE 2 8, 9 STO 0 6, 7 FE 2 5 4 2 3 4 5 6 7 8 9 0 4 COAX STO 2 3 FE 4 0 2 Air Pressure Connection for Tube OD 6 mm calibrated. Connection for Tube A OD 4 mm calibrated Dispensing Valve closed Channel A A Connection for Tube OD 4 mm calibrated Dispensing Valve open Channel A Connection for Tube A OD 4 mm calibrated Advance Slide backward Channel A Connection for Tube A OD 4 mm calibrated Advance Slide forward Channel A B Like 2 and 3, but Channel B. Like 4 and 5, but B Channel B. STO 2 1 FE 0 The following functions are provided by the solenoid valve module 97204: – Pneumatic control of two double-acting advancing slides A and B. – Pneumatic control of two double action stationary applicators A and B. – Electrical control of two rotorsprays. Herstellererklärung Henkel Loctite Deutschland GmbH Arabellastraße 17 D-81925 München Der Hersteller gemäß EU-Richtlinien Henkel Loctite Deutschland GmbH Arabellastraße 17 D-81925 München declares that the unit designated in the following is, as a result of its design and construction, in accordance with the European regulations, harmonized standards and national standards listed below. However, it is incomplete and the operation is prohibited until it can be determined that the machine, where it is built in, is in accordance with the provisions of the EC directives and standards given below. erklärt, dass das nachfolgend bezeichnete Gerät den unten aufgeführten europäischen Richtlinien, harmonisierten Normen und nationalen Normen entspricht. Es ist jedoch unvollständig und darf daher nicht in Betrieb genommen werden, bis sichergestellt ist, dass die Anlage, in die es eingebaut worden ist, den Bestimmungen der einschlägigen EU-Richtlinien und Normen entspricht. Designation of the unit Solenoid Valve Module Bezeichnung des Gerätes Unit number 97204 Gerätenummer 97204 Applicable EC Regulations EC Directive of Machinery 98/37/EEC including change 98/79/EC Einschlägige EU-Richtlinien Maschinen-Richtlinie 98/37/EG einschließlich Änderung 98/79/EG Date/Manufacturer’s signature 01/31/2003 / General Manager Datum/Hersteller-Unterschrift 31.01.2003 / General Manager (F. Löhr) This declaration is not valid if there are any changes not approved by Henkel Loctite. Order Code No./Bestellnummer 8952699 – Version/Ausgabe 01/2003 Ventilinsel (F. Löhr) Diese Erklärung ist ungültig, wenn es irgendwelche Änderungen gibt, die nicht von Henkel Loctite genehmigt worden sind.