226A LEGACYt LINE 16 HEAT PUMP WITH PURONr REFRIGERANT 1--1/2 TO 5 NOMINAL TONS Product Data INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S 15.5 -- 16.5 SEER/12.5 EER/9.0 -- 9.5 HSPF (based on tested combinations) S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 70 dBA S Sound level as low as 69 dBA with accessory sound shield Comfort S System supports Thermidistatt or standard 2--stage thermostat controls Reliability TM the environmentally sound refrigerant Bryant’s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 226A has been designed utilizing Bryant’s Puron refrigerant. The environmentally sound refrigerant allows consumers to make a responsible decision in the protection of the earth’s ozone layer. As an Energy Starr Partner, Bryant Heating & Cooling Systems has determined that this product meets the Energy Starr guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up--to--date ratings information. S Puronr refrigerant -- environmentally sound, won’t deplete the ozone layer and low lifetime service cost. S Front--seating service valves S 2--stage scroll compressor S Internal pressure relief valve S Internal thermal overload S Highpressure switch S Loss of charge switch S Filter drier S Balanced refrigeration system for maximum reliability Durability DuraGuardt protection package: S Solid, Durable sheet metal construction S Steel louver coil guard S Baked--on, complete outer coverage, powder paint Applications S Long--line -- up to 250 feet (76.2 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) MODEL NUMBER NOMENCLATURE 1 N 2 N 3 N 4 A 5 A/N 6 N 7 N 8 N 9 N 10 A/N 11 A/N 12 N 14 A 2 2 6 A N A 0 3 6 0 0 0 A Product Family 2=HP Tier SEER Voltage Variations Open Open Open Series 2= Legacy Series 6=16 SEER Major Series A=Puron N= 208--- 230--- 1 or 208/230--- 1 A = Standard 0=Not Defined 0=Not Defined 0=Not Defined A = Original Series Cooling Capacity ISO 9001:2000 the environmentally sound refrigerant REGISTERED 226A This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES FEATURES Unit Size --- Voltage, Series 024 036 048 060 X X X X 16.5 16.5 16.5 16.5 2---Stage Scroll Compressor X X X X Louvered Coil Guard X X X X Field Installed Filter Drier X X X X Front Seating Service Valves X X X X Internal Pressure Relief Valve X X X X Long Line capability X X X X Loss of Charge Switch X X X X High Pressure Switch X X X X Crankcase Heater X X X X Puron Refrigerant Maximum SEER Rating X = Standard 2 UNIT SIZE SERIES 024--- A 036--- A 048--- A 060--- A Operating Weight lb (kg) 281 (127) 273 (136) 303 (137) 349 (158) Shipping Weight lb (kg) 318 (144) 337 (153) 341 (155) 389 (177) Compressor Type Ultratechr Scroll REFRIGERANT Puron® (R---410A) Control TXV (Puron® Hard Shutoff) Charge lb (kg) 13.62 (6.18) 15.50 (7.03) 14.25 (6.46) 15.75 (7.14) Outdoor Htg Piston # 40 57 61 67 COND FAN Forward Swept Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 2700 4269 4350 5000 Motor HP 1/12 1/5 1/4 1/4 Motor RPM 800 810 825 810 COND COIL Face Area (Sq ft) 22.69 25.21 25.21 30.25 Fins per In. 20 20 20 20 Rows 2 2 2 2 Circuits 8 8 8 10 VALVE CONNECT. (In. ID) Vapor 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES (In. OD) Rated Vapor* 3/4 7/8 1 ---1/8 1 ---1/8 Max Liquid Line 3/8 * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron refrigerant: Unit Nominal Size (Btuh) 24,000 2 ---Stage HP with Puron 36,000 2 ---Stage HP with Puron 48,000 2 ---Stage HP with Puron 60,000 2 ---Stage HP with Puron Maximum Liquid Line Diameters (In. OD) 3/8 3/8 3/8 3/8 Vapor Line Diameters (In.) OD Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) Standard Application 26--- 50 51--- 80 Long Line Application Requires Accessories 81--- 100 101--- 125 126--- 150 151--- 175 176--- 200 201--- 225 226--- 250 (7.9--- 15.2) (15.5--- 24.4) (24.7--- 30.5) (30.8--- 38.1) (38.4--- 45.7) (46.0--- 50.3) (53.6--- 60.0) (61.3--- 68.6) (68.9--- 76.2) 5/8 0 1 1 2 3 3 4 4 5 3/4 0 1 1 1 1 1 1 1 1 5/8 1 2 4 5 6 7 9 10 11 3/4 0 0 1 1 2 2 3 3 4 7/8 0 0 — — — — — — — 3/4 1 2 2 3 4 5 6 7 7 7/8 0 1 1 2 2 2 3 3 4 1 ---1/8 0 0 — — — — — — — 3/4 1 2 4 5 6 8 9 10 11 7/8 0 1 2 2 3 4 4 5 5 1 ---1/8 0 0 — — — — — — — Standard Length = 80 ft. (24.4 m) or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit. — Applications in this area are not recommended due to insuficient oil return. 3 226A PHYSICAL DATA REFRIGERANT PIPING LENGTH LIMITATIONS Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications Units on equal level MAXIMUM ACTUAL LENGTH ft (m) 200 (61) MAXIMUM EQUIVALENT LENGTH{ ft (m) 250 (76.2) MAXIMUM VERTICAL SEPARATION ft (m) N/A 200 (61) 250 (76.2) 200 (61) Outdoor unit ABOVE indoor unit Outdoor unit BELOW indoor unit See Table ’Maximum Total Equivalent Length: Outdoor Unit BELOW Indoor Unit’ { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. Maximum Total Equivalent Length{ -- Outdoor Unit BELOW Indoor Unit 226A Size Liquid Line Diameter w/ TXV 024 HP with Puron 036 HP with Puron 048 HP with Puron 060 HP with Puron 0--- 20 (0 --- 6.1) HP with Puronr Refrigerant --- Maximum Total Equivalent Length{ Vertical Separation ft (m) Outdoor unit BELOW indoor unit; 21--- 30 31--- 40 41--- 50 51--- 60 61--- 70 (6.4 --- 9.1) (9.4 --- 12.2) (12.5 --- 15.2) (15.5 --- 18.3) (18.6 --- 21.3) 71--- 80 (21.6 --- 24.4) 3/8 250* 250* 250* 250* 250* 250* 250* 3//8 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 230 160 --- --- 3/8 250* 225* 190 150 110 --- --- --- --- * Maximum actual length not to exceed 200 ft (61 m) { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. --- --- = outside acceptable range LONG LINE APPLICATIONS An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these lengths, long line accessories are required: HP WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 3/8 80 (24.4) 20 (6.1) vertical or 80 (24.4) total 80 (24.4) Note: See Long Line Guideline for details THERMOSTATS THERMOSTAT / SUBBASE PKG. DESCRIPTION T6--- PRH01--- A Programmable Thermidistat T6--- NRH01--- A Non ---programmable Thermidistat T6--- PHP01* Preferred Series Programmable HP Stat T6--- NHP01* Preferred Series Non ---programmable HP Stat T2--- PHP01* Legacy Series Programmable HP Stat T2--- NHP01* Legacy Series Non ---programmable HP Stat *Serial numbers beginning with 2909 and thereafter. 4 ACCESSORIES KIT NUMBER KHALS0401LLS KHASS0606MPK* KSAHS2301AAA KSAHS2401AAA KSAHS2501AAA KSAHS2601AAA KSASF0101AAA KSASH2101COP KSATX0201PUR KSATX0301PUR KSATX0401PUR KSATX0501PUR STANDARD KIT NAME SOLENOID VALVE SNOW STAND HARD START KIT HARD START KIT HARD START KIT HARD START KIT SUPPORT FEET SOUND BLANKET TXV TXV TXV TXV CRANKCASE HEATER 024--- A X X X 036--- A X X 048--- A X X 060--- A X X X X X X X X X X X X X X X X S S X S S x = Accessory S = Standard * Available from RCD Accessory REQUIRED FOR LONG LINE APPLICATIONS* Accumulator Compressor Start Assist Capacitor and Relay Standard Yes Crankcase Heater Standard Yes (Standard with factory ---approved indoor unit) Hard Shutoff TXV REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km) Standard No Standard Yes Liquid Line Solenoid Valve No See Long --- Line Application Guideline Support Feet Recommended Recommended * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Piping and Longline Guideline. Accessory Description and Usage (Listed Alphabetically) 1. Compressor Start Assist -- Capacitor and Relay Start capacitor and relay gives a “hard” boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single--phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 2. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 3. Liquid--Line Solenoid Valve (LLS) An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. Usage Guideline: An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline. Suggested for all commercial applications. 4. Outdoor Air Temperature Sensor Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Bryant thermostats listed in this publication. 5. Outdoor Thermostat An SPDT temperature--actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user--selected set point. Usage Guideline: Electric supplemental heat applications in non--variable speed indoor units when electric heat staging is desired. 6. Secondary Outdoor Thermostat An SPDT temperature--actuated switch which turns on third--stage of supplemental electric heaters when outdoor air temperature drops below the second--stage set point. Usage Guideline: Outdoor thermostat applications where electric heater is capable of three--stage operation. 7. Snow Stand Coated wire rack which supports unit 18 in. (457.2 mm) above mounting pad to allow for drainage from unit base. Usage Guideline: Suggested in the following applications: Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 8. Thermostatic Expansion Valve (TXV) Bi--Flow A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Usage Guideline: Accessory required to meet ARI rating and system reliability, where indoor not equipped. Required in all heat pump applications designed with Puron refrigerant. 5 226A ACCESSORY USAGE GUIDELINE ELECTRICAL DATA UNIT SIZE --VOLTAGE, SERIES V/PH MAX MIN 253 197 024--- A 036--- A 226A 048--- A 208 ---230 ---1 LRA RLA FLA 52.0 15.4 0.5 19.8 14 14 56 (17.1) 54 (16.5) MAX FUSE* * or CKT BRK AMPS 30 82.0 16.7 1.2 22.1 12 12 57 (17.4) 54 (16.5) 35 96.0 26.9 1.3 34.8 8 8 89 (27.1) 84 (25.6) 50 OPER VOLTS* COMPR FAN MCA MIN WIRE SIZE{ MIN WIRE SIZE{ MAX LENGTH ft (m)} MAX LENGTH ft (m)} 60°C 75°C 60°C 75°C 060--- A 118.0 23.0 1.3 30.1 10 10 67 (20.4) 63 (19.2) 50 * Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30_C, consult table 310 ---16 of the NEC (NFPA 70). The ampacity of non ---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article 336 ---26. If other than uncoated (no ---plated), 60 or 75_C insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70). } Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time ---Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- Rated Load Amps NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards 90.1 SOUND POWER LEVEL (dBA) Unit Size --- Voltage, Series 024 036 048 060 Standard Rating dBA 73 --- High Stage 70 --- Low Stage 75 --- High Stage 72 --- Low Stage 76 --- High Stage 72 --- Low Stage 75 --- High Stage 74 --- Low Stage TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 50.0 50.0 57.0 57.5 54.0 54.5 52.5 51.5 59.5 58.5 61.0 60.5 62.0 61.0 60.5 59.5 64.5 62.5 70.0 64.5 66.0 65.0 66.5 66.5 67.0 65.5 69.5 67.0 71.0 67.0 72.0 71.0 63.0 64.0 64.5 64.5 65.5 64.0 66.5 66.0 61.5 61.0 62.5 62.0 63.0 61.0 64.0 62.5 58.5 54.0 58.0 56.0 59.5 57.0 57.0 55.5 NOTE: Tested in compliance with ARI 270 ---2008 but not listed with AHRI. SOUND POWER LEVEL (dBA) WITH ACCESSORY SOUNDSHIELD Unit Size --- Voltage, Series Standard Rating dBA TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment) 250 500 1000 2000 4000 8000 71 --- High Stage 50.5 59.5 024 69 ---Low Stage 50.0 58.0 74 --- High Stage 58.5 60.5 036 71 ---Low Stage 57.5 60.5 74 --- High Stage 55.5 61.5 048 71 ---Low Stage 55.0 61.0 73 --- High Stage 53.5 60.5 060 73 ---Low Stage 52.0 58.5 NOTE: Tested in compliance with ARI 270 ---2008 but not listed with AHRI. 125 64.0 62.0 69.5 64.5 65.5 64.5 66.0 65.5 65.5 64.5 68.5 66.0 70.0 66.5 70.5 69.5 61.5 62.0 63.5 63.5 64.5 63.0 65.0 64.5 58.5 59.0 61.0 61.0 60.5 60.0 59.5 59.5 53.5 50.5 55.0 53.5 55.0 54.0 52.5 52.0 CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE) UNIT SIZE --- VOLTAGE, SERIES 024--- A 036--- A 048--- A 060--- A REQUIRED SUBCOOLING _F (_C) 11.0 (6.1) HIGH STAGE 12.0 (6.7) HIGH STAGE 12.0 (6.7) HIGH STAGE 8.0 (4.4) HIGH STAGE 6 7 FIELD CONTROL SUPPLY CONN. 7/8" HOLE O O O O O 24 THRU 60 UNIT SIZE 3 1/2" 35" X 35" 26" X 26" VAPOR LINE CONN. D C 3/8" LIQUID LINE CONN. FIELD POWER SUPPLY CONN. 7/8" HOLE WITH 1 1/8" KNOCKOUT B O O X X O X = YES O = NO 39 1/8" 45 15/16" 35" A 226A060 208-230-1-60 O 35" A 226A048 230-1-60 O 39 1/8" O O 35 3/4" X X 35" A 226A036 35" A 226A024 B ELECTRICAL SERIES A CHARACTERISTICS 208/230-3-60 UNIT DIMENSIONS -- ENGLISH 460-3-60 SQ. A 7/8" 7/8" 7/8" 3/4" D AIR DISCHARGE 3 7/8" 3 7/8" 3 7/8" 3 3/4" C 6 9/16" 6 9/16" 6 9/16" 6 9/16" E 28 7/16" 28 7/16" 28 7/16" 28 7/16" F 1 7/8" 9 1/8" 9 1/8" 9 1/8" 9 1/8" G P 1 1/8" 16 1/2" 16 1/2" 16 1/4" 16" M K 18" 17 1/2" 15 1/2" 14 1/2" N 15 1/2" G P 317.5 389.0 341.4 336.6 SHIPPING AIR IN AIR IN AIR DISCHARGE E N F 2. MINIMUM OUTDOOR AMBIENT IN COOLING F, MAX. OPERATING 125 MODE IS 55 1. ALLOW 24" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW. NOTES: 348.5 272.4 300.3 302.5 280.5 OPERATING SHIPPING WEIGHT (lbs) WEIGHT (lbs) 226A 19 1/2" 17 1/2" 18 1/2" M 3/8" TIEDOWN KNOCKOUTS (2) PLACES L AIR IN 5/8" 5/8" 5/8" 1/2" L 3 13/16" 2 15/16" 2 15/16" 2 15/16" 2 13/16" K AIR IN 8 A A A 226A036 226A048 226A060 B O O O O O O O O O O O O FIELD CONTROL SUPPLY CONN. 22.23 HOLE 993.8 993.8 1166.8 889.0 889.0 X = YES O = NO 908.0 889.0 24 THRU 60 D VAPOR C LINE CONN. 88.9 B 889.0 FIELD POWER SUPPLY CONN. 22.23 HOLE WITH 28.58 KNOCKOUT X X X X UNIT SIZE A 226A024 ELECTRICAL SERIES A CHARACTERISTICS 230-1-60 UNIT DIMENSIONS -- SI 460-3-60 SQ. A 22.2 22.2 22.2 19.1 D AIR DISCHARGE 98.4 98.4 98.4 95.2 C 166.7 166.7 166.7 166.7 E 722.3 722.3 722.3 722.3 F 47.6 231.8 231.8 231.8 231.8 G P 74.6 74.6 74.6 71.4 K K 28.6 419.1 419.1 412.8 406.4 M 457.2 444.5 393.7 368.3 N G P M 176.8 155.2 153.0 144.3 AIR IN AIR IN AIR DISCHARGE E N F 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING C, MAX. 52 MODE IS 13 1. ALLOW 609.6 CLEARANCE TO SERVICE SIDE OF UNIT, 1219.2 ABOVE UNIT, 152.4 ON ONE SIDE, 304.8 ON REMAINING SIDE, AND 609.6 BETWEEN UNITS FOR PROPER AIRFLOW. 158.4 137.5 136.2 127.5 OPERATING SHIPPING WEIGHT (Kgs) WEIGHT (Kgs) NOTES: 495.3 444.5 469.9 393.7 9.53 TIEDOWN KNOCKOUTS (2) PLACES L 96.8 AIR IN 15.9 15.9 15.9 12.7 L 226A 9 BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH 0 (17.78) 10 (-12.22) 20 (-6.67) 30 (-1.11) 40 (4.44) AIR AT 70˚F (21.1˚C) AND BASED ON INDOOR ENT. -10 (-23) 0 10 OUTDOOR TEMPERATURE ˚F(˚C) 50 (10) 226A 60 (15.56) AT RATED CFM 70 (21.11) 0 80 (26.67) 2.9299 5.8598 20 11.7196 14.6495 17.5794 20.5093 8.7897 226ANA024 FV4CNf002 226ANA036 FV4CNf003 226ANA048 FV4CNf005 226ANA060 FV4CNB006 23.4392 30 40 50 60 70 80 226A BALANCE POINT WORKSHEET - HIGH STAGE KW 10 BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH 0 (17.78) 0 10 20 30 40 50 10 (-12.22) 20 (-6.67) 40 (4.44) 50 (10) 60 (15.56) 70 (21.11) 226ANA024 FV4CNf002 226ANA036 FV4CNf003 226ANA048 FV4CNf005 BASED ON INDOOR ENT. AIR AT 70_F (21.1_C) AND AT RATED CFM OUTDOOR TEMPERATURE ˚F(˚C) 30 (-1.11) 226ANA060 FV4CNB006 80 (26.67) 0 2.9299 5.8598 8.7897 11.7196 14.6495 17.5794 20.5093 70 60 23.4392 80 226A BALANCE POINT WORKSHEET -- LOW STAGE 226A KW 11 Model Number 3495356 226ANA024 ---A 3494627 226ANA024 ---A 3494625 226ANA024 ---A 3494626 226ANA024 ---A 3494628 226ANA024 ---A 3494629 226ANA024 ---A 3494630 226ANA024 ---A 3494624 226ANA024 ---A 3514276 226ANA024 ---A 3514275 226ANA024 ---A 3494631 226ANA024 ---A 3494639 226ANA024 ---A 3494636 226ANA024 ---A 3494637 226ANA024 ---A 3494638 226ANA024 ---A 3494640 226ANA024 ---A 3494641 226ANA024 ---A 3494642 226ANA024 ---A 3494632 226ANA024 ---A 3494633 226ANA024 ---A 3494634 226ANA024 ---A 3494635 226ANA024 ---A 3514278 226ANA024 ---A 3514277 226ANA024 ---A 3494643 226ANA024 ---A 3494647 226ANA024 ---A 3494645 226ANA024 ---A 3494646 226ANA024 ---A 3494648 226ANA024 ---A 3494649 226ANA024 ---A 3494650 226ANA024 ---A 3494644 226ANA024 ---A 3514280 226ANA024 ---A 3514279 226ANA024 ---A 3494651 226ANA024 ---A 3494659 226ANA024 ---A 3494656 226ANA024 ---A 3494657 226ANA024 ---A 3494658 226ANA024 ---A 3494660 226ANA024 ---A 3494661 226ANA024 ---A 3494662 226ANA024 ---A 3494652 226ANA024 ---A 3494653 226ANA024 ---A 3494654 226ANA024 ---A 3494655 226ANA024 ---A See notes on pg. 28 AHRI Ref. No. Coil Model Number †FV4CNF002 CAP**2414A** CAP**2414A** CAP**2414A** CAP**2414A** CAP**2414A** CAP**2414A** CAP**2414A** CAP**2414A** CAP**2414A** CAP**2414A**+TDR CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A** CAP**2417A**+TDR CAP**3014A** CAP**3014A** CAP**3014A** CAP**3014A** CAP**3014A** CAP**3014A** CAP**3014A** CAP**3014A** CAP**3014A** CAP**3014A**+TDR CAP**3017A** CAP**3017A** CAP**3017A** CAP**3017A** CAP**3017A** CAP**3017A** CAP**3017A** CAP**3017A** CAP**3017A** CAP**3017A** CAP**3017A** COMBINATION RATINGS 313*AV024045 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 353AAV036040 353AAV036060 353AAV036080 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 313*AV024045 315(A,J)AV036070 315(A,J)AV048090 353AAV036040 353AAV036060 353AAV036080 355(A,C)AV042060 368RAN036105 374RAN036105 313*AV024045 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 353AAV036040 353AAV036060 353AAV036080 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 368RAN036105 374RAN036105 313*AV024045 315(A,J)AV036070 315(A,J)AV048090 353AAV036040 353AAV036060 353AAV036080 355(A,C)AV042060 368RAN036105 374RAN036105 Furnace Model Number 23,200 23,000 22,800 22,800 23,400 23,400 23,200 23,200 23,200 22,800 22,600 23,200 22,800 23,000 23,000 23,400 23,600 23,400 23,200 22,800 22,600 22,800 23,200 22,800 22,600 23,200 22,800 22,800 23,400 23,400 23,400 23,200 23,200 22,800 22,600 23,200 22,800 23,000 23,000 23,600 23,600 23,400 23,200 22,800 22,600 22,800 High 18,800 18,800 18,100 18,200 19,200 19,000 19,700 18,100 18,800 18,300 18,200 18,800 18,100 18,200 19,400 19,300 19,200 19,800 18,100 18,000 19,100 19,400 18,800 18,300 18,200 18,800 18,000 18,100 19,300 19,000 19,700 18,100 18,800 18,300 18,200 18,800 18,000 18,200 19,400 19,400 19,300 19,800 18,100 18,000 19,100 19,300 Low Cooling Capacity 12.6 12.3 12.2 12.4 12.6 12.6 12.6 12.4 12.5 12.3 11.2 12.3 12.3 12.5 12.5 12.7 12.7 12.7 12.5 12.3 12.4 12.5 12.5 12.3 11.2 12.3 12.3 12.4 12.7 12.6 12.7 12.4 12.5 12.3 11.2 12.4 12.3 12.5 12.5 12.8 12.8 12.8 12.5 12.4 12.4 12.6 EER 15.7 15.5 15.5 15.5 16.0 16.0 16.0 15.5 16.0 15.5 13.5 16.0 15.5 15.5 16.0 16.0 16.0 16.0 15.5 15.5 16.0 16.0 16.0 15.5 13.5 15.5 15.5 15.5 16.0 16.0 16.0 15.5 16.0 15.5 13.5 16.0 15.5 15.5 16.0 16.0 16.0 16.0 15.5 15.5 16.0 16.0 SEER 700 710 660 670 745 760 735 725 715 660 700 725 660 670 675 765 780 750 725 660 630 665 715 660 700 720 660 670 760 770 740 725 715 660 700 735 660 670 675 785 795 760 725 660 630 665 226A 560 580 495 505 635 600 735 500 585 520 560 585 495 505 675 655 625 750 500 490 630 665 585 520 560 585 495 505 650 615 740 500 585 520 560 595 495 505 675 680 650 760 500 490 630 665 Low ID CFM High Cooling E Capacity 26,600 26,600 26,400 26,400 26,600 26,600 26,600 26,600 26,600 26,400 27,000 26,600 26,400 26,400 26,400 26,600 26,800 26,600 26,600 26,400 26,200 26,400 26,600 26,400 27,000 26,600 26,400 26,400 26,600 26,600 26,600 26,600 26,600 26,400 27,000 26,600 26,400 26,400 26,400 26,600 26,600 26,600 26,600 26,400 26,200 26,400 High Temp E COP 3.18 3.08 3.06 3.08 3.14 3.14 3.12 3.10 3.10 3.04 2.92 3.10 3.06 3.08 3.08 3.16 3.16 3.14 3.12 3.06 3.04 3.08 3.12 3.06 2.92 3.08 3.04 3.08 3.12 3.14 3.12 3.10 3.10 3.04 2.90 3.08 3.06 3.08 3.08 3.14 3.16 3.14 3.12 3.06 3.04 3.08 9.0 8.7 8.5 8.5 9.0 9.0 9.1 8.5 8.8 8.5 8.5 8.7 8.5 8.5 9.0 9.1 9.0 9.2 8.5 8.5 9.0 9.0 8.8 8.5 8.5 9.0 8.5 8.5 9.1 9.1 9.1 8.5 9.0 8.6 8.5 9.0 8.5 8.6 9.0 9.2 9.2 9.3 8.5 8.5 9.2 9.0 HSPF Low Temp H Capacity 16,100 16,200 16,100 16,000 16,200 16,200 16,200 16,200 16,200 16,100 16,700 16,200 16,000 16,000 16,100 16,200 16,300 16,200 16,200 16,000 15,900 16,000 16,100 16,000 16,700 16,300 16,100 16,000 16,300 16,300 16,200 16,200 16,200 16,100 16,700 16,300 16,000 16,000 16,100 16,300 16,300 16,200 16,200 16,000 15,900 16,000 AHRI Standard Ratings H COP 2.82 2.76 2.74 2.78 2.82 2.82 2.82 2.80 2.80 2.74 2.60 2.78 2.76 2.78 2.76 2.84 2.84 2.82 2.80 2.76 2.74 2.76 2.80 2.76 2.60 2.80 2.76 2.80 2.86 2.86 2.84 2.82 2.82 2.76 2.62 2.80 2.78 2.80 2.80 2.88 2.88 2.86 2.84 2.78 2.76 2.80 12 Model Number 3514282 226ANA024 ---A 3514281 226ANA024 ---A 3494663 226ANA024 ---A 3494667 226ANA024 ---A 3494665 226ANA024 ---A 3494666 226ANA024 ---A 3494668 226ANA024 ---A 3494669 226ANA024 ---A 3494670 226ANA024 ---A 3494664 226ANA024 ---A 3494680 226ANA024 ---A 3494689 226ANA024 ---A 3494686 226ANA024 ---A 3494687 226ANA024 ---A 3494688 226ANA024 ---A 3494690 226ANA024 ---A 3494682 226ANA024 ---A 3494683 226ANA024 ---A 3494684 226ANA024 ---A 3494685 226ANA024 ---A 3514284 226ANA024 ---A 3514283 226ANA024 ---A 3494707 226ANA024 ---A 3494709 226ANA024 ---A 3494710 226ANA024 ---A 3494717 226ANA024 ---A 3494718 226ANA024 ---A 3494713 226ANA024 ---A 3494714 226ANA024 ---A 3494715 226ANA024 ---A 3494716 226ANA024 ---A 3514286 226ANA024 ---A 3514285 226ANA024 ---A 3494737 226ANA024 ---A 3494890 226ANA024 ---A 3494891 226ANA024 ---A 3494892 226ANA024 ---A 3494887 226ANA024 ---A 3494888 226ANA024 ---A 3494889 226ANA024 ---A 3514301 226ANA024 ---A 3494896 226ANA024 ---A 3494897 226ANA024 ---A 3494898 226ANA024 ---A 3494893 226ANA024 ---A 3494894 226ANA024 ---A See notes on pg. 28 AHRI Ref. No. CAP**3017A** CAP**3017A** CAP**3017A**+TDR CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A**+TDR CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A**+TDR CAP**3619A** CAP**3619A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A**+TDR CNPH*2417A** CNPH*2417A** CNPH*2417A** CNPH*2417A** CNPH*2417A** CNPH*2417A** CNPH*2417A** CNPH*3017A** CNPH*3017A** CNPH*3017A** CNPH*3017A** CNPH*3017A** Coil Model Number COMBINATION RATINGS CONTINUED 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 374RAN036105 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 355(A,C)AV042080 355(A,C)AV060080 359BAV036040 359BAV036060 315(A,J)AV048090 315(A,J)AV060110 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 368RAN036105 374RAN036105 313*AV024045 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 353AAV036040 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 368RAN036105 374RAN036105 313*AV024045 315(A,J)AV036070 315(A,J)AV048090 353AAV036040 353AAV036060 353AAV036080 355(A,C)AV042060 368RAN036105 374RAN036105 Furnace Model Number 23,200 22,800 22,600 23,200 22,800 23,000 23,600 23,600 23,400 23,200 22,600 23,400 22,800 23,000 23,000 23,600 23,400 22,800 22,600 23,000 23,200 22,800 22,600 23,400 23,600 23,000 23,000 23,400 22,800 22,600 23,000 23,200 23,000 22,600 22,800 23,000 23,000 22,800 22,600 23,000 22,800 22,800 23,000 23,000 22,800 22,600 High 18,800 18,300 18,200 18,800 18,100 18,200 19,400 19,200 19,800 18,100 18,200 18,900 18,100 18,200 19,400 19,600 18,100 18,000 19,100 19,400 18,800 18,300 18,200 18,900 19,200 18,200 19,400 18,200 18,100 19,100 19,400 18,900 18,300 18,200 18,100 18,200 19,400 18,100 19,200 19,400 18,400 18,100 18,200 19,400 18,000 19,100 Low Cooling Capacity 12.6 12.4 11.2 12.4 12.3 12.5 12.0 12.7 12.7 12.5 11.2 12.4 12.4 12.5 12.6 12.8 12.6 12.4 12.5 12.6 12.6 12.5 11.2 12.2 12.3 12.6 12.7 12.7 12.5 12.5 12.7 12.6 12.5 11.2 12.3 12.4 12.4 12.3 12.4 12.5 12.2 12.4 12.5 12.5 12.4 12.4 EER 16.0 15.5 13.5 16.0 15.5 15.5 16.0 16.0 16.0 15.5 13.5 16.0 15.5 16.0 16.0 16.0 15.5 15.5 16.0 16.0 16.0 16.0 13.5 16.0 16.0 16.0 16.0 16.0 15.5 16.0 16.0 16.0 15.5 13.5 15.5 15.5 16.0 15.5 16.0 16.0 15.5 15.5 15.5 16.0 15.5 16.0 SEER 715 660 700 725 660 670 765 780 750 725 700 740 660 670 675 790 725 660 630 665 715 660 700 765 820 670 675 725 660 630 665 715 660 700 660 670 675 660 630 665 660 660 670 675 660 630 585 520 560 590 495 505 660 630 750 500 560 600 495 505 675 695 500 490 630 665 585 520 560 595 640 505 675 500 490 630 665 585 520 560 495 505 675 490 630 665 520 495 505 675 490 630 Low ID CFM High Cooling 226A E Capacity 26,600 26,400 27,000 26,600 26,400 26,400 26,600 26,800 26,600 26,600 27,000 26,800 26,400 26,400 26,400 26,800 26,600 26,400 26,200 26,400 26,600 26,400 27,000 26,800 27,000 26,400 26,400 26,600 26,400 26,200 26,400 26,600 26,400 27,000 26,600 26,600 26,800 26,600 26,600 26,600 26,600 26,400 26,400 26,400 26,400 26,200 High Temp E COP 3.10 3.06 2.90 3.10 3.08 3.10 3.16 3.16 3.16 3.12 2.92 3.12 3.08 3.10 3.10 3.18 3.14 3.08 3.06 3.10 3.14 3.08 2.92 3.10 3.12 3.12 3.12 3.16 3.10 3.06 3.10 3.14 3.10 2.92 3.12 3.16 3.14 3.14 3.10 3.14 3.12 3.06 3.08 3.08 3.08 3.04 9.0 8.6 8.5 9.0 8.6 8.6 9.2 9.2 9.3 8.7 8.5 9.0 8.6 8.6 9.1 9.3 8.7 8.6 9.2 9.1 9.0 8.7 8.5 9.0 9.1 8.6 9.2 8.7 8.6 9.2 9.1 9.0 8.7 8.5 8.5 8.6 9.0 8.5 8.8 9.0 8.6 8.6 8.6 9.1 8.5 9.2 HSPF Low Temp H Capacity 16,200 16,000 16,700 16,300 16,100 16,000 16,300 16,300 16,200 16,200 16,700 16,300 16,100 16,000 16,100 16,300 16,200 16,000 16,000 16,000 16,200 16,000 16,700 16,500 16,600 16,000 16,000 16,100 16,000 15,900 16,000 16,100 16,000 16,700 16,100 16,100 16,100 16,100 16,000 16,100 16,100 16,100 16,000 16,100 16,000 16,000 AHRI Standard Ratings H COP 2.82 2.78 2.62 2.80 2.78 2.80 2.86 2.88 2.86 2.84 2.62 2.82 2.78 2.82 2.80 2.90 2.84 2.80 2.76 2.80 2.84 2.80 2.62 2.80 2.82 2.82 2.82 2.86 2.80 2.76 2.80 2.84 2.80 2.62 2.74 2.78 2.76 2.76 2.74 2.76 2.74 2.78 2.80 2.80 2.78 2.76 13 Model Number 3494895 226ANA024 ---A 3514302 226ANA024 ---A 3494904 226ANA024 ---A 3494899 226ANA024 ---A 3494900 226ANA024 ---A 3494901 226ANA024 ---A 3494902 226ANA024 ---A 3494903 226ANA024 ---A 3514303 226ANA024 ---A 3495004 226ANA024 ---A 3495005 226ANA024 ---A 3495003 226ANA024 ---A 3495006 226ANA024 ---A 3495011 226ANA024 ---A 3495012 226ANA024 ---A 3495013 226ANA024 ---A 3495007 226ANA024 ---A 3495008 226ANA024 ---A 3495009 226ANA024 ---A 3495010 226ANA024 ---A 3514290 226ANA024 ---A 3514289 226ANA024 ---A 3495014 226ANA024 ---A 3495016 226ANA024 ---A 3495017 226ANA024 ---A 3495015 226ANA024 ---A 3495018 226ANA024 ---A 3495023 226ANA024 ---A 3495024 226ANA024 ---A 3495025 226ANA024 ---A 3495019 226ANA024 ---A 3495020 226ANA024 ---A 3495021 226ANA024 ---A 3495022 226ANA024 ---A 3514292 226ANA024 ---A 3514291 226ANA024 ---A 3495026 226ANA024 ---A 3514294 226ANA024 ---A 3514293 226ANA024 ---A 3495038 226ANA024 ---A 3495039 226ANA024 ---A 3495040 226ANA024 ---A 3495035 226ANA024 ---A 3495036 226ANA024 ---A 3495037 226ANA024 ---A 3514296 226ANA024 ---A See notes on pg. 28 AHRI Ref. No. CNPH*3017A** CNPH*3017A** CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPV*2414A** CNPV*2414A** CNPV*2414A** CNPV*2414A**+TDR CNPV*2417A** CNPV*2417A** CNPV*2417A** CNPV*2417A** CNPV*2417A** CNPV*2417A** CNPV*2417A** CNPV*2417A** CNPV*2417A** CNPV*2417A**+TDR CNPV*3014A** CNPV*3014A** CNPV*3014A** CNPV*3014A**+TDR CNPV*3017A** CNPV*3017A** CNPV*3017A** CNPV*3017A** CNPV*3017A** CNPV*3017A** CNPV*3017A** CNPV*3017A** CNPV*3017A** CNPV*3017A**+TDR CNPV*3117A** CNPV*3117A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** Coil Model Number COMBINATION RATINGS CONTINUED 368RAN036105 374RAN036105 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 368RAN036105 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 368RAN036105 374RAN036105 315(A,J)AV036070 315(A,J)AV048090 355(A,C)AV042060 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 368RAN036105 374RAN036105 355(A,C)AV060100 374RAN036105 315(A,J)AV036070 353AAV036060 353AAV036080 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 374RAN036105 315(A,J)AV036070 315(A,J)AV048090 355(A,C)AV042060 Furnace Model Number 22,800 22,800 22,800 23,600 23,400 22,800 22,600 22,800 22,800 22,800 23,000 23,200 22,600 22,800 23,000 23,000 23,200 22,800 22,600 23,000 23,200 22,800 22,600 22,800 22,800 23,200 22,600 22,800 23,000 23,000 23,200 22,800 22,600 22,800 23,200 22,800 23,200 23,400 23,000 22,800 23,000 23,000 22,800 22,600 22,800 23,200 High 19,300 18,300 18,100 19,200 19,800 18,000 19,100 19,300 18,300 18,100 18,200 18,200 18,300 18,100 18,200 19,400 18,200 18,100 19,200 19,400 18,900 18,400 18,300 18,000 18,200 18,100 18,200 18,100 18,200 19,400 18,100 18,000 19,100 19,300 18,800 18,300 18,200 18,900 18,400 18,100 18,200 19,400 18,000 19,100 19,300 18,800 Low Cooling Capacity 12.6 12.4 12.4 12.7 12.7 12.4 12.4 12.6 12.4 12.2 12.4 12.4 11.2 12.3 12.4 12.4 12.4 12.3 12.4 12.5 12.4 12.2 11.2 12.2 12.4 12.4 11.2 12.3 12.5 12.6 12.5 12.4 12.4 12.6 12.5 12.4 11.2 12.7 12.5 12.4 12.5 12.5 12.4 12.4 12.6 12.5 EER 16.0 15.5 15.5 16.0 16.0 15.5 16.0 16.0 15.5 15.5 15.5 15.5 13.5 15.5 15.5 16.0 15.5 15.5 16.0 16.0 16.0 15.6 13.5 15.5 15.5 15.5 13.5 15.5 15.5 16.0 15.5 15.5 16.0 16.0 16.0 15.5 13.5 16.0 15.5 15.5 15.5 16.0 15.5 16.0 16.0 16.0 SEER 665 660 660 790 755 660 630 665 660 660 670 725 700 660 670 675 725 660 630 665 715 660 700 660 670 725 700 660 670 675 725 660 630 665 715 660 840 715 660 660 670 675 660 630 665 715 226A 665 520 495 645 755 490 630 665 520 495 505 500 560 495 505 675 500 490 630 665 585 520 560 495 505 500 560 495 505 675 500 490 630 665 585 520 560 585 520 495 505 675 490 630 665 585 Low ID CFM High Cooling E Capacity 26,400 26,400 26,400 26,600 26,600 26,400 26,200 26,400 26,400 26,600 26,600 26,800 27,200 26,600 26,600 26,800 26,800 26,600 26,600 26,600 26,800 26,600 27,200 26,400 26,400 26,600 27,000 26,400 26,400 26,400 26,600 26,400 26,200 26,400 26,600 26,400 27,400 26,800 26,800 26,400 26,400 26,400 26,400 26,200 26,400 26,600 High Temp E COP 3.08 3.06 3.06 3.16 3.14 3.08 3.04 3.08 3.06 3.12 3.16 3.18 2.98 3.12 3.16 3.14 3.18 3.14 3.10 3.14 3.18 3.12 2.98 3.06 3.08 3.10 2.90 3.06 3.08 3.08 3.12 3.06 3.04 3.08 3.12 3.06 2.92 3.26 3.22 3.06 3.08 3.08 3.08 3.04 3.08 3.12 9.0 8.7 8.6 9.2 9.3 8.6 9.2 9.0 8.7 8.6 8.6 8.6 8.5 8.5 8.6 9.0 8.6 8.6 9.0 9.0 8.9 8.6 8.5 8.6 8.6 8.7 8.5 8.6 8.6 9.1 8.7 8.5 9.2 9.0 9.0 8.7 8.4 9.2 8.8 8.5 8.6 9.1 8.5 9.2 9.0 9.0 HSPF Low Temp H Capacity 16,000 16,000 16,100 16,300 16,200 16,000 16,000 16,000 16,000 16,100 16,100 16,300 16,700 16,100 16,100 16,100 16,300 16,100 16,000 16,100 16,200 16,100 16,700 16,100 16,100 16,200 16,700 16,100 16,000 16,100 16,200 16,000 16,000 16,000 16,200 16,000 17,100 16,200 16,100 16,100 16,000 16,100 16,000 16,000 16,000 16,200 AHRI Standard Ratings H COP 2.80 2.78 2.78 2.88 2.86 2.78 2.76 2.80 2.78 2.74 2.78 2.80 2.60 2.74 2.78 2.76 2.80 2.76 2.74 2.76 2.80 2.74 2.60 2.76 2.80 2.82 2.62 2.78 2.80 2.80 2.84 2.78 2.76 2.80 2.82 2.78 2.66 2.88 2.84 2.78 2.80 2.80 2.78 2.76 2.80 2.82 14 CNPV*3617A** CNPV*3617A**+TDR CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A**+TDR CNPV*3717A** CNPV*3717A** CSPH*2412A** CSPH*2412A** CSPH*2412A** CSPH*2412A** CSPH*2412A** CSPH*2412A**+TDR CSPH*3012A** CSPH*3012A** CSPH*3012A** CSPH*3012A** CSPH*3012A** CSPH*3012A**+TDR CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A**+TDR †FV4CN(B,F)003 FV4CN(B,F)005 FV4CNB006 CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A** CAP**3614A**+TDR CAP**3617A** CAP**3617A** 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 226ANA024 ---A 3514295 3495055 3495060 3495061 3495057 3495058 3495059 3514298 3514297 3495078 3514300 3514299 3495249 3495250 3495251 3495252 3514304 3495253 3495254 3495255 3495256 3495257 3514305 3495258 3495259 3495260 3495261 3495262 3514306 3495281 3495350 226ANA036 ---A 3495351 226ANA036 ---A 3495353 226ANA036 ---A 3494674 226ANA036 ---A 3494675 226ANA036 ---A 3494672 226ANA036 ---A 3494673 226ANA036 ---A 3494676 226ANA036 ---A 3494677 226ANA036 ---A 3494678 226ANA036 ---A 3494679 226ANA036 ---A 3494671 226ANA036 ---A 3494681 226ANA036 ---A 3494698 226ANA036 ---A 3494699 226ANA036 ---A See notes on pg. 28 Coil Model Number Model Number AHRI Ref. No. COMBINATION RATINGS CONTINUED 313*AV024045 313*AV048070 313*AV024045 313*AV048070 315(A,J)AV036070 315(A,J)AV048090 353AAV036040 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV042060 313*AV024045 353AAV036040 353AAV036060 353AAV036080 374RAN036105 313*AV024045 353AAV036040 353AAV036060 353AAV036080 374RAN036105 368RAN036105 374RAN036105 313*AV024045 353AAV036040 353AAV036060 353AAV036080 374RAN036105 315(A,J)AV048090 315(A,J)AV060110 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 368RAN036105 374RAN036105 374RAN036105 Furnace Model Number 34,000 35,200 35,600 33,400 33,400 33,400 33,600 33,800 33,800 33,600 33,800 33,800 33,600 33,600 33,600 22,800 22,600 23,000 23,000 22,800 22,600 23,000 23,200 22,800 22,600 23,400 23,000 23,000 23,200 23,200 23,200 22,800 23,200 23,200 23,400 23,400 23,400 22,800 22,600 23,400 23,800 23,800 23,600 23,000 22,600 High 28,000 28,600 29,000 27,000 28,000 26,400 26,600 27,400 27,400 27,200 28,200 27,000 27,400 27,200 28,000 18,300 18,200 18,200 19,400 18,000 19,100 19,300 18,800 18,300 18,200 19,000 18,400 18,600 18,900 18,600 19,600 18,300 18,300 18,700 19,200 19,000 19,700 18,300 18,200 18,900 19,500 19,300 19,900 18,300 18,300 Low Cooling Capacity 12.5 13.0 13.3 11.5 11.8 11.9 12.2 12.2 12.1 12.1 12.2 12.0 11.4 11.6 12.0 12.4 11.2 12.6 12.5 12.4 12.5 12.6 12.6 12.4 11.2 12.7 12.6 12.2 12.5 12.4 12.5 12.2 11.3 12.3 12.6 12.6 12.6 12.3 11.2 12.4 12.8 12.8 12.8 12.4 11.2 EER 15.5 16.0 16.0 14.5 14.5 15.0 15.0 15.0 15.0 15.0 15.0 15.0 13.5 15.0 14.5 15.5 13.5 15.5 16.0 15.5 16.0 16.0 16.0 15.5 13.5 16.0 15.5 15.5 16.0 16.0 16.0 15.5 14.0 15.5 16.0 16.0 16.0 15.5 13.5 16.0 16.0 16.0 16.0 15.5 14.0 SEER 1,050 1,050 1,050 1,045 1,020 1,005 1,005 1,035 1,045 1,030 1,050 1,055 1,100 1,075 1,050 660 700 670 675 660 630 665 715 660 700 715 660 685 710 725 700 660 700 715 750 765 735 660 700 735 780 795 760 660 700 840 840 840 735 895 660 670 775 785 755 955 725 880 750 920 520 560 505 675 490 630 665 585 520 560 585 520 555 585 545 700 520 560 580 640 605 735 520 560 590 675 640 760 520 560 Low ID CFM High Cooling 226A 36,400 37,200 37,400 37,200 37,000 36,800 36,600 36,800 36,800 36,800 36,800 37,000 37,600 37,400 37,000 E Capacity 26,400 27,000 26,400 26,400 26,400 26,200 26,400 26,600 26,400 27,000 27,000 26,800 26,800 26,800 26,800 26,800 26,600 27,600 26,600 26,600 26,800 26,600 26,400 27,000 27,000 26,800 27,000 26,800 26,600 27,200 High Temp 3.76 3.96 4.06 3.58 3.62 3.64 3.66 3.70 3.70 3.68 3.70 3.68 3.60 3.62 3.66 E COP 3.06 2.90 3.10 3.08 3.08 3.04 3.08 3.12 3.06 2.92 3.32 3.30 3.12 3.16 3.18 3.16 3.10 3.00 3.08 3.14 3.16 3.14 3.06 2.92 3.18 3.26 3.26 3.24 3.16 3.00 9.0 9.2 9.2 8.5 8.7 8.5 8.5 8.7 8.7 8.6 9.0 8.6 8.5 8.5 8.8 8.7 8.3 8.6 9.1 8.6 9.2 9.0 9.0 8.7 8.5 9.3 9.0 8.7 9.0 8.8 9.1 8.7 8.5 8.8 9.1 9.0 9.2 8.6 8.5 9.1 9.4 9.3 9.5 8.8 8.5 HSPF Low Temp 22,000 22,200 22,200 22,800 22,400 22,200 22,200 22,200 22,200 22,200 22,400 22,400 23,000 22,800 22,400 H Capacity 16,000 16,700 16,000 16,100 16,000 16,000 16,000 16,200 16,000 16,700 16,300 16,100 16,300 16,200 16,300 16,200 16,200 17,000 16,300 16,300 16,300 16,200 16,100 17,100 16,400 16,300 16,400 16,300 16,100 16,800 AHRI Standard Ratings 2.64 2.74 2.80 2.54 2.56 2.58 2.60 2.62 2.62 2.62 2.62 2.60 2.52 2.56 2.58 H COP 2.78 2.62 2.80 2.80 2.78 2.76 2.80 2.82 2.78 2.62 2.90 2.86 2.76 2.82 2.82 2.80 2.74 2.66 2.80 2.86 2.86 2.84 2.76 2.66 2.84 2.92 2.92 2.90 2.82 2.64 15 Model Number 3494700 226ANA036 ---A 3494701 226ANA036 ---A 3494695 226ANA036 ---A 3494696 226ANA036 ---A 3494697 226ANA036 ---A 3494702 226ANA036 ---A 3494703 226ANA036 ---A 3494704 226ANA036 ---A 3494705 226ANA036 ---A 3494706 226ANA036 ---A 3494691 226ANA036 ---A 3494692 226ANA036 ---A 3494693 226ANA036 ---A 3494694 226ANA036 ---A 3514308 226ANA036 ---A 3514310 226ANA036 ---A 3514307 226ANA036 ---A 3514309 226ANA036 ---A 3494708 226ANA036 ---A 3494711 226ANA036 ---A 3494712 226ANA036 ---A 3494729 226ANA036 ---A 3494730 226ANA036 ---A 3494731 226ANA036 ---A 3494725 226ANA036 ---A 3494726 226ANA036 ---A 3494727 226ANA036 ---A 3494728 226ANA036 ---A 3494732 226ANA036 ---A 3494733 226ANA036 ---A 3494734 226ANA036 ---A 3494735 226ANA036 ---A 3494736 226ANA036 ---A 3494720 226ANA036 ---A 3494721 226ANA036 ---A 3494722 226ANA036 ---A 3494723 226ANA036 ---A 3494724 226ANA036 ---A 3494719 226ANA036 ---A 3514312 226ANA036 ---A 3514314 226ANA036 ---A 3514311 226ANA036 ---A 3514313 226ANA036 ---A 3494738 226ANA036 ---A 3494749 226ANA036 ---A 3494750 226ANA036 ---A See notes on pg. 28 AHRI Ref. No. CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A** CAP**3617A**+TDR CAP**3619A** CAP**3619A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A** CAP**3621A**+TDR CAP**4221A** CAP**4221A** Coil Model Number COMBINATION RATINGS CONTINUED 313*AV048070 313*AV048090 359BAV036060 359BAV060080 313*AV048070 313*AV048090 313*AV060110 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV036040 353AAV036060 353AAV036080 353AAV048080 353AAV060100 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 368RAN036105 368RAN060120 374RAN036105 374RAN060120 313*AV048090 313*AV060110 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 353AAV036040 353AAV036060 353AAV036080 353AAV048080 353AAV060100 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 368RAN036105 368RAN060120 374RAN036105 374RAN060120 Furnace Model Number 34,000 34,000 33,400 33,600 33,600 33,800 34,000 33,800 34,000 33,800 33,800 33,600 33,600 33,800 33,800 33,600 33,400 33,600 33,800 33,800 34,200 33,800 34,000 34,200 33,600 33,800 33,800 33,800 34,000 34,200 34,000 34,000 34,000 33,800 33,600 33,600 33,800 33,800 33,400 33,800 33,800 33,400 33,600 33,800 34,000 34,400 High 28,200 29,200 26,400 26,600 26,600 27,600 27,600 27,400 28,400 29,200 27,000 26,400 26,200 26,600 28,000 27,400 27,600 27,000 27,800 27,400 28,200 28,200 28,400 29,400 26,600 26,600 26,600 26,600 27,800 27,800 27,600 28,600 29,400 27,000 26,600 26,200 26,600 26,800 26,600 28,000 27,400 27,600 27,000 27,800 28,400 28,600 Low Cooling Capacity 12.3 12.5 12.0 12.2 12.2 12.1 12.2 12.2 12.2 12.5 12.1 12.0 12.1 12.1 12.1 12.3 12.0 12.1 11.4 11.7 12.1 12.0 12.4 12.6 12.3 12.3 12.4 12.5 12.3 12.3 12.3 12.3 12.6 12.2 12.1 12.1 12.2 12.3 12.0 12.2 12.4 12.1 12.2 11.4 12.1 12.5 EER 15.0 14.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 14.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 13.5 14.5 15.0 14.5 15.0 14.5 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 14.0 15.5 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 13.5 14.5 15.5 SEER 1,060 1,085 1,005 1,005 1,020 1,065 1,080 1,055 1,080 1,015 1,055 1,030 1,010 1,040 1,065 1,005 975 1,000 1,200 1,100 1,180 1,070 1,085 1,115 1,005 1,020 1,010 1,015 1,085 1,110 1,080 1,100 1,045 1,055 1,030 1,010 1,040 1,010 1,000 1,065 1,005 975 1,000 1,200 1,070 1,085 226A 930 1,315 660 670 675 795 810 775 985 1,340 725 660 630 665 880 765 800 720 960 785 920 940 955 1,360 670 675 675 675 815 830 795 1,005 1,375 725 660 630 665 690 675 880 765 800 720 960 940 950 Low ID CFM High Cooling E Capacity 36,800 36,800 36,800 36,600 36,600 36,800 37,000 36,800 37,000 36,600 36,800 36,800 36,600 36,800 37,000 36,600 36,600 36,600 38,000 37,400 37,400 37,000 36,800 37,000 36,600 36,600 36,400 36,400 37,000 37,000 36,800 37,000 36,600 36,800 36,800 36,600 36,800 36,600 36,600 37,000 36,400 36,600 36,600 38,000 37,200 37,000 High Temp E COP 3.74 3.78 3.64 3.68 3.70 3.74 3.74 3.72 3.74 3.72 3.72 3.66 3.66 3.70 3.70 3.70 3.62 3.66 3.64 3.66 3.76 3.68 3.78 3.80 3.70 3.72 3.72 3.74 3.76 3.78 3.76 3.76 3.76 3.72 3.68 3.68 3.72 3.70 3.64 3.72 3.72 3.64 3.68 3.64 3.72 3.82 8.8 9.0 8.5 8.5 8.5 8.8 8.8 8.7 9.0 9.0 8.6 8.5 8.5 8.5 8.8 8.7 8.6 8.5 8.5 8.5 8.8 9.0 9.0 9.1 8.5 8.5 8.5 8.5 8.8 8.9 8.8 9.0 9.0 8.6 8.5 8.5 8.5 8.5 8.5 8.8 8.7 8.7 8.5 8.5 8.9 9.0 HSPF Low Temp H Capacity 22,200 22,200 22,200 22,000 22,200 22,200 22,400 22,200 22,400 22,000 22,200 22,400 22,200 22,200 22,400 22,000 22,000 22,000 23,400 22,800 22,800 22,400 22,200 22,200 22,000 22,000 22,000 21,800 22,200 22,400 22,200 22,400 22,000 22,200 22,200 22,200 22,200 22,000 22,200 22,400 22,000 22,000 22,000 23,400 22,600 22,400 AHRI Standard Ratings H COP 2.64 2.66 2.58 2.62 2.62 2.64 2.64 2.64 2.64 2.64 2.62 2.60 2.60 2.62 2.60 2.62 2.58 2.60 2.54 2.58 2.64 2.60 2.66 2.68 2.62 2.64 2.64 2.66 2.66 2.66 2.64 2.64 2.66 2.64 2.60 2.62 2.62 2.62 2.58 2.62 2.64 2.58 2.62 2.54 2.62 2.68 16 Model Number 3494751 226ANA036 ---A 3494745 226ANA036 ---A 3494746 226ANA036 ---A 3494747 226ANA036 ---A 3494748 226ANA036 ---A 3494752 226ANA036 ---A 3494753 226ANA036 ---A 3494754 226ANA036 ---A 3494755 226ANA036 ---A 3494756 226ANA036 ---A 3494740 226ANA036 ---A 3494741 226ANA036 ---A 3494742 226ANA036 ---A 3494743 226ANA036 ---A 3494744 226ANA036 ---A 3494739 226ANA036 ---A 3514316 226ANA036 ---A 3514318 226ANA036 ---A 3514315 226ANA036 ---A 3514317 226ANA036 ---A 3494757 226ANA036 ---A 3494765 226ANA036 ---A 3494762 226ANA036 ---A 3494763 226ANA036 ---A 3494764 226ANA036 ---A 3494758 226ANA036 ---A 3494759 226ANA036 ---A 3494760 226ANA036 ---A 3494761 226ANA036 ---A 3514320 226ANA036 ---A 3514319 226ANA036 ---A 3494766 226ANA036 ---A 3494774 226ANA036 ---A 3494775 226ANA036 ---A 3494776 226ANA036 ---A 3494771 226ANA036 ---A 3494772 226ANA036 ---A 3494773 226ANA036 ---A 3494777 226ANA036 ---A 3494778 226ANA036 ---A 3494779 226ANA036 ---A 3494780 226ANA036 ---A 3494767 226ANA036 ---A 3494768 226ANA036 ---A 3494769 226ANA036 ---A 3494770 226ANA036 ---A See notes on pg. 28 AHRI Ref. No. CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A** CAP**4221A**+TDR CAP**4224A** CAP**4224A** CAP**4224A** CAP**4224A** CAP**4224A** CAP**4224A** CAP**4224A** CAP**4224A** CAP**4224A** CAP**4224A** CAP**4224A**+TDR CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** Coil Model Number COMBINATION RATINGS CONTINUED 313*AV024045 313*AV048070 313*AV048090 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 353AAV036040 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 313*AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 313*AV060110 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV036040 353AAV036060 353AAV036080 353AAV048080 353AAV060100 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 368RAN036105 368RAN060120 374RAN036105 374RAN060120 Furnace Model Number 34,600 34,000 34,000 34,000 34,000 34,400 34,400 34,200 34,400 34,200 34,200 34,000 33,800 34,000 34,000 33,800 34,000 34,000 33,600 33,800 34,400 34,400 34,000 34,000 34,200 34,000 33,800 34,000 34,000 34,000 33,800 34,400 34,600 34,800 35,000 34,600 34,600 34,800 35,000 35,000 35,000 35,000 34,800 34,600 34,600 34,800 High 29,600 26,800 26,800 26,800 26,800 28,000 28,000 27,800 28,800 29,600 27,200 26,600 26,400 26,800 27,000 26,800 28,200 27,600 27,800 27,200 28,200 28,600 26,800 26,800 26,800 26,600 26,400 26,800 27,000 27,600 27,200 28,200 28,000 29,000 29,200 27,200 27,200 27,400 28,400 28,600 28,200 29,400 27,800 27,200 26,800 27,200 Low Cooling Capacity 12.6 12.4 12.4 12.5 12.6 12.3 12.3 12.3 12.4 12.7 12.3 12.1 12.2 12.3 12.4 12.1 12.2 12.5 12.2 12.3 11.4 12.5 12.4 12.5 12.6 12.2 12.2 12.3 12.4 12.5 12.3 11.4 11.9 12.3 12.7 12.3 12.6 12.6 12.6 12.6 12.6 12.6 12.5 12.4 12.4 12.5 EER 14.5 15.0 15.0 15.0 15.5 15.5 15.5 15.5 15.0 14.5 15.5 15.0 15.0 15.0 15.5 15.0 15.0 15.5 15.0 15.0 13.5 15.5 15.0 15.5 15.5 15.0 15.0 15.0 15.5 15.5 15.0 13.5 15.0 15.0 15.5 15.5 15.5 15.5 16.0 16.0 16.0 15.5 15.5 15.5 15.0 15.5 SEER 1,110 1,005 1,020 1,010 1,015 1,085 1,105 1,075 1,100 1,040 1,055 1,030 1,010 1,040 1,010 1,000 1,065 1,005 975 1,000 1,260 1,090 1,020 1,010 1,015 1,030 1,010 1,040 1,010 1,005 1,000 1,260 1,075 1,055 1,065 1,005 1,005 1,020 1,070 1,085 1,060 1,085 1,055 1,030 1,010 1,040 1,355 670 675 675 675 820 825 790 1,000 1,375 725 660 630 665 690 675 880 765 800 720 1,010 960 675 675 675 660 630 665 690 765 720 1,010 755 925 935 660 670 675 805 815 780 990 725 660 630 665 Low ID CFM High Cooling 226A E Capacity 37,000 36,600 36,800 36,600 36,600 37,000 37,200 37,000 37,200 36,800 37,000 37,000 36,800 36,800 36,600 36,800 37,000 36,600 36,600 36,600 38,500 37,000 36,800 36,600 36,600 37,000 36,800 36,800 36,600 36,600 36,600 38,500 38,000 37,600 37,400 37,400 37,200 37,200 37,600 37,600 37,400 37,600 37,600 37,400 37,400 37,400 High Temp E COP 3.84 3.74 3.76 3.76 3.80 3.80 3.82 3.80 3.80 3.80 3.78 3.72 3.72 3.76 3.76 3.70 3.76 3.76 3.68 3.72 3.72 3.82 3.76 3.78 3.80 3.74 3.72 3.76 3.76 3.76 3.72 3.72 3.82 3.86 3.96 3.84 3.90 3.90 3.96 3.96 3.94 3.96 3.92 3.88 3.88 3.90 9.0 8.6 8.5 8.5 8.5 8.9 9.0 8.8 9.1 9.0 8.7 8.5 8.5 8.5 8.6 8.5 8.8 8.8 8.8 8.5 8.5 9.0 8.5 8.5 8.6 8.5 8.5 8.5 8.6 8.8 8.6 8.5 8.7 9.0 9.1 8.6 8.7 8.7 9.0 9.0 9.0 9.1 8.7 8.6 8.6 8.7 HSPF Low Temp H Capacity 22,400 22,000 22,200 22,000 22,000 22,400 22,400 22,400 22,400 22,000 22,400 22,400 22,200 22,200 22,000 22,200 22,400 22,000 22,000 22,200 23,600 22,400 22,200 22,000 22,000 22,200 22,200 22,200 22,000 22,000 22,000 23,600 23,000 22,800 22,600 22,600 22,400 22,400 22,600 22,600 22,600 22,600 22,600 22,600 22,400 22,600 AHRI Standard Ratings H COP 2.70 2.64 2.64 2.66 2.68 2.68 2.68 2.66 2.66 2.68 2.66 2.62 2.62 2.64 2.64 2.60 2.64 2.66 2.60 2.62 2.58 2.68 2.66 2.66 2.68 2.62 2.64 2.64 2.66 2.66 2.64 2.58 2.62 2.66 2.72 2.66 2.70 2.70 2.72 2.72 2.72 2.72 2.70 2.68 2.68 2.70 17 Model Number 3514322 226ANA036 ---A 3514324 226ANA036 ---A 3514321 226ANA036 ---A 3514323 226ANA036 ---A 3494787 226ANA036 ---A 3494799 226ANA036 ---A 3494800 226ANA036 ---A 3494795 226ANA036 ---A 3494796 226ANA036 ---A 3494797 226ANA036 ---A 3494798 226ANA036 ---A 3494801 226ANA036 ---A 3494802 226ANA036 ---A 3494803 226ANA036 ---A 3494804 226ANA036 ---A 3494790 226ANA036 ---A 3494791 226ANA036 ---A 3494792 226ANA036 ---A 3494793 226ANA036 ---A 3494794 226ANA036 ---A 3494789 226ANA036 ---A 3514326 226ANA036 ---A 3514328 226ANA036 ---A 3514325 226ANA036 ---A 3514327 226ANA036 ---A 3494815 226ANA036 ---A 3494817 226ANA036 ---A 3494818 226ANA036 ---A 3494819 226ANA036 ---A 3494820 226ANA036 ---A 3494831 226ANA036 ---A 3494828 226ANA036 ---A 3494829 226ANA036 ---A 3494830 226ANA036 ---A 3494824 226ANA036 ---A 3494825 226ANA036 ---A 3494826 226ANA036 ---A 3494827 226ANA036 ---A 3494823 226ANA036 ---A 3514330 226ANA036 ---A 3514329 226ANA036 ---A 3494840 226ANA036 ---A 3494907 226ANA036 ---A 3494908 226ANA036 ---A 3494909 226ANA036 ---A 3494910 226ANA036 ---A See notes on pg. 28 AHRI Ref. No. CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A**+TDR CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A**+TDR CAP**4823A** CAP**4823A** CAP**4823A** CAP**4823A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A**+TDR CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A** Coil Model Number COMBINATION RATINGS CONTINUED 313*AV024045 313*AV048070 313*AV048090 353AAV036040 359BAV036040 359BAV036060 359BAV060080 359BAV060100 313*AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 368RAN060120 374RAN060120 313*AV048070 313*AV048090 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV036040 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 368RAN036105 368RAN060120 374RAN036105 374RAN060120 368RAN036105 368RAN060120 374RAN036105 374RAN060120 Furnace Model Number 34,800 34,800 34,400 34,600 35,200 34,600 34,800 34,400 34,400 34,400 34,600 34,800 34,800 34,800 34,800 34,600 34,400 34,400 34,600 34,400 34,200 34,600 34,400 34,200 34,400 35,000 34,200 34,600 35,200 35,000 35,000 34,600 34,600 34,600 34,400 34,400 34,600 34,400 34,200 34,400 34,400 35,000 33,400 33,400 33,800 33,800 High 28,800 28,200 28,400 27,800 29,000 28,800 29,000 27,200 27,200 27,200 27,200 28,200 28,400 28,000 29,200 27,600 27,000 26,600 27,000 27,200 27,200 28,600 28,000 28,200 27,600 28,600 28,200 28,000 29,000 28,600 29,000 27,200 27,200 27,200 27,000 26,600 27,000 27,400 27,200 28,000 27,600 28,600 27,000 28,000 28,000 27,400 Low Cooling Capacity 12.4 12.7 12.4 12.5 11.7 12.2 12.7 12.5 12.5 12.6 12.7 12.6 12.5 12.5 12.6 12.5 12.3 12.5 12.4 12.5 12.2 12.4 12.6 12.3 12.4 11.6 11.8 12.1 12.4 12.5 12.7 12.6 12.6 12.8 12.3 12.4 12.5 12.6 12.3 12.7 12.5 11.6 11.5 11.9 12.2 12.2 EER 15.5 15.5 15.5 15.5 14.0 15.0 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.0 15.5 15.5 15.5 15.5 15.5 15.5 15.0 13.5 14.5 15.0 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.3 15.5 15.5 15.5 15.5 15.5 13.5 14.5 14.5 15.0 15.0 SEER 1,065 1,005 975 1,000 1,260 1,065 1,075 1,005 1,020 1,010 1,015 1,080 1,100 1,070 1,095 1,055 1,030 1,010 1,040 1,010 1,000 1,065 1,005 975 1,000 1,260 1,070 1,115 1,200 1,120 1,090 1,020 1,010 1,015 1,030 1,010 1,040 1,010 1,000 1,005 1,000 1,260 1,055 1,030 1,035 1,045 226A 880 765 800 720 1,010 935 945 670 675 675 675 810 820 785 995 725 660 630 665 690 675 880 765 800 720 1,010 825 800 935 885 955 675 675 675 660 630 665 690 675 765 720 1,010 740 905 905 785 Low ID CFM High Cooling E Capacity 37,600 37,200 37,200 37,200 39,000 37,600 37,400 37,000 37,000 37,000 37,000 37,400 37,400 37,400 37,400 37,400 37,200 37,200 37,200 37,000 37,200 37,400 37,000 37,000 37,000 39,000 37,800 37,800 38,000 37,600 37,400 37,000 37,000 37,000 37,200 37,000 37,200 37,000 37,200 37,000 37,000 39,000 37,200 37,000 36,600 36,800 High Temp E COP 3.90 3.92 3.82 3.86 3.88 3.82 3.92 3.84 3.86 3.86 3.90 3.92 3.92 3.90 3.90 3.88 3.82 3.82 3.86 3.86 3.78 3.86 3.86 3.78 3.82 3.82 3.74 3.84 3.94 3.92 3.94 3.86 3.88 3.90 3.84 3.84 3.86 3.86 3.80 3.86 3.82 3.82 3.58 3.62 3.70 3.70 9.0 9.0 9.0 8.8 8.7 8.8 9.0 8.6 8.6 8.6 8.7 9.0 9.0 8.9 9.1 8.7 8.5 8.5 8.6 8.7 8.6 9.0 8.8 8.9 8.7 8.6 8.7 8.7 9.0 9.0 9.1 8.7 8.7 8.7 8.6 8.5 8.6 8.7 8.6 8.8 8.8 8.6 8.5 8.5 8.8 8.7 HSPF Low Temp H Capacity 22,800 22,200 22,400 22,400 24,000 22,800 22,400 22,200 22,400 22,200 22,200 22,400 22,600 22,400 22,600 22,400 22,400 22,400 22,400 22,200 22,400 22,600 22,200 22,200 22,200 23,800 23,000 23,000 23,000 22,600 22,400 22,200 22,200 22,200 22,400 22,400 22,400 22,200 22,400 22,200 22,200 23,800 22,800 22,400 22,200 22,200 AHRI Standard Ratings H COP 2.68 2.70 2.66 2.68 2.64 2.66 2.72 2.68 2.68 2.68 2.70 2.70 2.70 2.70 2.70 2.68 2.66 2.66 2.68 2.68 2.64 2.66 2.68 2.64 2.66 2.62 2.60 2.64 2.70 2.70 2.72 2.68 2.70 2.72 2.66 2.66 2.68 2.68 2.64 2.70 2.66 2.62 2.54 2.56 2.62 2.62 18 Model Number 3494911 226ANA036 ---A 3494912 226ANA036 ---A 3494913 226ANA036 ---A 3494906 226ANA036 ---A 3494905 226ANA036 ---A 3514367 226ANA036 ---A 3514368 226ANA036 ---A 3494914 226ANA036 ---A 3494915 226ANA036 ---A 3494916 226ANA036 ---A 3494917 226ANA036 ---A 3494918 226ANA036 ---A 3494919 226ANA036 ---A 3494920 226ANA036 ---A 3494921 226ANA036 ---A 3514369 226ANA036 ---A 3514370 226ANA036 ---A 3494922 226ANA036 ---A 3494930 226ANA036 ---A 3494931 226ANA036 ---A 3494932 226ANA036 ---A 3494925 226ANA036 ---A 3494926 226ANA036 ---A 3494927 226ANA036 ---A 3494928 226ANA036 ---A 3494929 226ANA036 ---A 3494933 226ANA036 ---A 3494934 226ANA036 ---A 3494935 226ANA036 ---A 3494936 226ANA036 ---A 3494923 226ANA036 ---A 3494924 226ANA036 ---A 3514371 226ANA036 ---A 3494952 226ANA036 ---A 3495048 226ANA036 ---A 3495049 226ANA036 ---A 3495050 226ANA036 ---A 3495045 226ANA036 ---A 3495046 226ANA036 ---A 3495047 226ANA036 ---A 3495051 226ANA036 ---A 3495052 226ANA036 ---A 3495053 226ANA036 ---A 3495054 226ANA036 ---A 3495041 226ANA036 ---A 3495042 226ANA036 ---A See notes on pg. 28 AHRI Ref. No. CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A** CNPH*3617A**+TDR CNPH*4221A** CNPH*4221A** CNPH*4221A** CNPH*4221A** CNPH*4221A** CNPH*4221A** CNPH*4221A** CNPH*4221A** CNPH*4221A** CNPH*4221A**+TDR CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A**+TDR CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** Coil Model Number COMBINATION RATINGS CONTINUED 313*AV024045 313*AV048070 313*AV048090 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 353AAV036040 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV042060 355(A,C)AV042080 313*AV024045 313*AV048070 313*AV048090 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV036040 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV060100 355(A,C)AV060120 374RAN060120 313*AV024045 313*AV048070 313*AV048090 353AAV036040 353AAV036060 353AAV036080 353AAV048080 374RAN036105 374RAN060120 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV042060 355AAV042040 374RAN036105 374RAN060120 Furnace Model Number 33,800 33,600 33,800 33,800 33,400 33,200 33,400 33,200 33,800 34,000 34,200 34,200 34,400 34,200 34,200 33,600 33,800 33,600 34,600 34,800 35,000 34,400 34,600 34,600 34,600 34,800 35,000 35,000 35,000 35,400 34,600 34,600 34,400 34,200 33,400 33,400 33,800 33,400 33,600 33,600 33,800 33,800 33,600 33,800 33,800 33,600 High 27,400 27,200 28,200 27,000 26,600 27,400 27,000 27,200 27,400 28,200 28,400 27,800 27,800 27,600 28,800 27,800 27,200 27,600 28,000 29,000 29,200 27,000 27,200 27,200 27,200 27,200 28,400 28,600 28,200 29,400 27,200 27,400 27,600 28,000 27,000 28,000 28,000 26,400 26,600 26,600 27,400 27,400 27,200 28,200 27,000 26,400 Low Cooling Capacity 12.1 12.2 12.2 12.0 11.8 11.9 12.0 11.4 11.7 12.0 12.4 12.4 12.3 12.3 12.4 12.1 12.2 11.5 11.9 12.3 12.8 12.4 12.6 12.6 12.7 12.8 12.7 12.6 12.6 12.5 12.5 12.6 12.5 11.7 11.5 11.9 12.2 11.9 12.1 12.1 12.2 12.1 12.2 12.2 12.0 11.9 EER 15.0 15.0 15.0 15.0 14.5 15.0 15.0 13.5 14.5 14.5 15.0 15.5 15.5 15.0 15.0 15.0 15.0 13.5 15.0 15.0 15.5 15.0 15.5 15.5 15.5 15.8 16.0 16.0 15.5 15.5 15.5 15.5 15.5 14.0 14.5 14.5 14.5 15.0 15.0 15.0 15.0 15.0 15.0 14.5 15.0 15.0 SEER 1,055 1,035 1,055 1,055 1,000 975 1,000 1,050 1,070 1,045 1,055 1,065 1,080 1,055 1,075 975 1,000 1,050 1,100 1,080 1,090 1,005 1,005 1,020 1,010 1,015 1,090 1,115 1,085 1,230 1,040 1,010 1,000 1,050 1,055 1,030 1,035 1,005 1,005 1,020 1,045 1,055 1,035 1,055 1,055 1,030 795 765 965 725 675 800 720 840 745 915 925 795 805 770 980 800 720 840 765 945 960 660 670 675 675 675 820 835 795 1,020 665 690 720 840 740 905 905 660 670 675 780 795 765 965 725 660 Low ID CFM High Cooling 226A E Capacity 36,800 36,800 36,800 36,800 36,800 36,600 36,600 37,400 37,600 37,200 37,000 37,000 37,200 37,000 37,200 36,800 36,800 37,600 38,000 37,600 37,400 37,200 37,000 37,000 37,000 37,000 37,400 37,600 37,400 38,000 37,200 37,000 37,000 38,000 37,200 37,000 36,600 36,800 36,600 36,600 36,800 36,800 36,800 36,800 37,000 36,800 High Temp E COP 3.70 3.68 3.70 3.68 3.62 3.60 3.64 3.56 3.68 3.70 3.80 3.80 3.80 3.78 3.78 3.68 3.72 3.62 3.80 3.86 3.94 3.82 3.86 3.88 3.88 3.92 3.94 3.94 3.92 3.98 3.88 3.88 3.84 3.70 3.58 3.62 3.70 3.62 3.66 3.68 3.70 3.70 3.68 3.70 3.68 3.64 8.7 8.6 8.8 8.6 8.5 8.6 8.5 8.5 8.5 8.8 9.0 8.8 8.8 8.8 9.0 8.7 8.5 8.5 8.7 9.0 9.1 8.6 8.7 8.7 8.7 8.7 9.0 9.0 9.0 9.2 8.7 8.8 8.8 8.5 8.5 8.7 8.8 8.5 8.5 8.5 8.7 8.8 8.6 8.9 8.6 8.5 HSPF Low Temp H Capacity 22,400 22,200 22,400 22,400 22,200 22,200 22,200 22,800 22,800 22,600 22,200 22,400 22,400 22,400 22,400 22,200 22,200 23,000 23,000 22,800 22,400 22,400 22,200 22,200 22,200 22,200 22,600 22,600 22,600 23,000 22,400 22,200 22,200 23,200 22,800 22,400 22,200 22,200 22,000 22,200 22,200 22,400 22,200 22,400 22,400 22,400 AHRI Standard Ratings H COP 2.62 2.62 2.62 2.60 2.56 2.56 2.58 2.52 2.58 2.60 2.66 2.66 2.66 2.66 2.66 2.60 2.62 2.54 2.62 2.66 2.72 2.66 2.70 2.70 2.70 2.72 2.72 2.72 2.72 2.72 2.70 2.70 2.68 2.58 2.54 2.56 2.62 2.58 2.60 2.60 2.62 2.62 2.62 2.62 2.60 2.58 19 Model Number 3495043 226ANA036 ---A 3495044 226ANA036 ---A 3514338 226ANA036 ---A 3514340 226ANA036 ---A 3514337 226ANA036 ---A 3514339 226ANA036 ---A 3495056 226ANA036 ---A 3495072 226ANA036 ---A 3495073 226ANA036 ---A 3495068 226ANA036 ---A 3495069 226ANA036 ---A 3495070 226ANA036 ---A 3495071 226ANA036 ---A 3495074 226ANA036 ---A 3495075 226ANA036 ---A 3495076 226ANA036 ---A 3495077 226ANA036 ---A 3495063 226ANA036 ---A 3495064 226ANA036 ---A 3495065 226ANA036 ---A 3495066 226ANA036 ---A 3495067 226ANA036 ---A 3495062 226ANA036 ---A 3514342 226ANA036 ---A 3514344 226ANA036 ---A 3514341 226ANA036 ---A 3514343 226ANA036 ---A 3495079 226ANA036 ---A 3514346 226ANA036 ---A 3514348 226ANA036 ---A 3514345 226ANA036 ---A 3514347 226ANA036 ---A 3495108 226ANA036 ---A 3495109 226ANA036 ---A 3495110 226ANA036 ---A 3495105 226ANA036 ---A 3495106 226ANA036 ---A 3495107 226ANA036 ---A 3495111 226ANA036 ---A 3495112 226ANA036 ---A 3495113 226ANA036 ---A 3495114 226ANA036 ---A 3495101 226ANA036 ---A 3495102 226ANA036 ---A 3495103 226ANA036 ---A 3495104 226ANA036 ---A See notes on pg. 28 AHRI Ref. No. CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A** CNPV*3617A**+TDR CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A** CNPV*3621A**+TDR CNPV*3717A** CNPV*3717A** CNPV*3717A** CNPV*3717A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** Coil Model Number COMBINATION RATINGS CONTINUED 368RAN036105 368RAN060120 374RAN036105 374RAN060120 313*AV024045 313*AV048070 313*AV048090 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 353AAV036040 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 313*AV048070 313*AV048090 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV036040 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 368RAN036105 368RAN060120 374RAN036105 374RAN060120 355(A,C)AV060080 355(A,C)AV060100 368RAN036105 368RAN060120 374RAN036105 374RAN060120 Furnace Model Number 33,400 33,600 33,600 33,600 33,200 33,400 33,800 33,600 33,800 33,600 33,600 33,600 33,600 33,800 33,800 33,800 33,800 33,800 33,600 33,400 33,600 33,600 33,400 33,800 33,600 33,200 33,400 33,800 35,200 35,000 34,600 34,800 34,200 34,200 34,600 34,200 34,200 34,400 34,600 34,600 34,400 34,600 34,400 34,200 34,200 34,400 High 26,200 26,400 27,800 27,200 27,400 27,000 27,800 28,000 28,000 26,600 26,600 26,600 26,600 27,400 27,600 27,200 28,400 27,000 26,400 26,200 26,400 26,800 26,600 27,800 27,200 27,400 27,000 27,800 29,000 28,400 28,600 28,000 27,600 28,600 28,600 26,800 27,000 27,000 28,000 28,200 27,800 29,000 27,400 26,800 26,600 27,000 Low Cooling Capacity 12.0 12.0 11.9 12.3 11.9 12.0 11.3 11.9 12.2 12.1 12.1 12.2 12.3 12.2 12.2 12.2 12.2 12.1 11.9 12.0 12.0 12.2 11.9 12.0 12.3 12.0 12.1 11.3 12.5 12.8 12.5 12.6 11.8 12.1 12.6 12.2 12.4 12.4 12.5 12.4 12.4 12.5 12.3 12.2 12.3 12.3 EER 14.5 15.0 14.5 15.0 15.0 15.0 13.5 14.5 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 14.5 14.5 15.0 15.0 15.0 15.0 15.0 15.0 13.5 15.5 16.0 15.5 15.5 15.0 15.0 15.5 15.0 15.5 15.0 15.5 15.5 15.5 15.5 15.5 15.0 15.0 15.0 SEER 1,010 1,040 1,065 1,005 975 1,000 1,200 1,035 1,045 1,005 1,020 1,010 1,015 1,050 1,065 1,040 1,065 1,055 1,030 1,010 1,040 1,010 1,000 1,065 1,005 975 1,000 1,200 1,065 1,005 975 1,000 1,070 1,045 1,055 1,005 1,005 1,020 1,060 1,075 1,050 1,075 1,055 1,030 1,010 1,040 226A 630 665 880 765 800 720 960 905 910 670 675 675 675 785 800 765 970 725 660 630 665 690 675 880 765 800 720 960 880 765 800 720 745 915 925 660 670 675 795 805 775 980 725 660 630 665 Low ID CFM High Cooling E Capacity 36,800 36,800 37,000 36,600 36,600 36,600 38,000 37,000 36,800 36,600 36,600 36,600 36,600 36,800 36,800 36,800 36,800 36,800 36,800 36,600 36,800 36,600 36,800 37,000 36,600 36,600 36,600 38,000 37,800 37,200 37,200 37,400 37,600 37,400 37,200 37,000 37,000 37,000 37,200 37,400 37,200 37,400 37,200 37,200 37,000 37,200 High Temp E COP 3.64 3.68 3.66 3.68 3.60 3.64 3.64 3.62 3.72 3.66 3.68 3.68 3.70 3.70 3.70 3.70 3.70 3.68 3.64 3.64 3.68 3.68 3.62 3.66 3.68 3.60 3.64 3.64 3.94 3.96 3.86 3.90 3.72 3.76 3.84 3.76 3.80 3.80 3.84 3.84 3.84 3.84 3.82 3.78 3.78 3.80 8.5 8.5 8.7 8.6 8.6 8.5 8.5 8.7 8.8 8.5 8.5 8.5 8.5 8.8 8.7 8.7 8.9 8.6 8.5 8.5 8.5 8.5 8.5 8.7 8.6 8.6 8.5 8.5 9.0 9.0 9.0 8.8 8.6 8.9 9.0 8.6 8.6 8.6 9.0 8.9 8.9 9.0 8.7 8.5 8.5 8.6 HSPF Low Temp H Capacity 22,200 22,200 22,400 22,000 22,200 22,200 23,400 22,400 22,200 22,000 22,200 22,000 22,000 22,200 22,400 22,200 22,400 22,400 22,400 22,200 22,200 22,000 22,200 22,400 22,000 22,200 22,200 23,400 22,800 22,400 22,400 22,400 23,000 22,600 22,400 22,400 22,200 22,400 22,400 22,600 22,400 22,600 22,400 22,400 22,400 22,400 AHRI Standard Ratings H COP 2.58 2.60 2.60 2.62 2.56 2.58 2.54 2.58 2.62 2.60 2.60 2.62 2.62 2.62 2.62 2.62 2.62 2.62 2.58 2.58 2.60 2.60 2.56 2.60 2.62 2.56 2.60 2.54 2.70 2.72 2.68 2.70 2.60 2.62 2.68 2.62 2.66 2.66 2.68 2.68 2.68 2.68 2.66 2.64 2.64 2.66 20 Model Number 3514350 226ANA036 ---A 3514352 226ANA036 ---A 3514349 226ANA036 ---A 3514351 226ANA036 ---A 3495115 226ANA036 ---A 3495128 226ANA036 ---A 3495129 226ANA036 ---A 3495130 226ANA036 ---A 3495131 226ANA036 ---A 3514354 226ANA036 ---A 3514356 226ANA036 ---A 3514353 226ANA036 ---A 3514355 226ANA036 ---A 3495116 226ANA036 ---A 3495132 226ANA036 ---A 3514358 226ANA036 ---A 3514360 226ANA036 ---A 3514357 226ANA036 ---A 3514359 226ANA036 ---A 3495117 226ANA036 ---A 3495159 226ANA036 ---A 3495160 226ANA036 ---A 3495155 226ANA036 ---A 3495156 226ANA036 ---A 3495157 226ANA036 ---A 3495158 226ANA036 ---A 3495161 226ANA036 ---A 3495162 226ANA036 ---A 3495163 226ANA036 ---A 3495164 226ANA036 ---A 3495150 226ANA036 ---A 3495151 226ANA036 ---A 3495152 226ANA036 ---A 3495153 226ANA036 ---A 3495154 226ANA036 ---A 3495149 226ANA036 ---A 3514362 226ANA036 ---A 3514364 226ANA036 ---A 3514361 226ANA036 ---A 3514363 226ANA036 ---A 3495118 226ANA036 ---A 3495119 226ANA036 ---A 3495180 226ANA036 ---A 3495189 226ANA036 ---A 3495186 226ANA036 ---A 3495187 226ANA036 ---A See notes on pg. 28 AHRI Ref. No. CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A** CNPV*4217A**+TDR CNPV*4221A** CNPV*4221A** CNPV*4221A** CNPV*4221A** CNPV*4221A** CNPV*4221A** CNPV*4221A** CNPV*4221A** CNPV*4221A**+TDR CNPV*4221A**+TDR CNPV*4321A** CNPV*4321A** CNPV*4321A** CNPV*4321A** CNPV*4321A**+TDR CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A**+TDR CNPV*4821A**+TDR CNPV*4821A**+TDR CNPV*4824A** CNPV*4824A** CNPV*4824A** Coil Model Number COMBINATION RATINGS CONTINUED 313*AV048090 315(A,J)AV060110 315(A,J)AV066135 368RAN036105 368RAN060120 374RAN036105 374RAN060120 355(A,C)AV042060 313*AV048070 313*AV048090 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV036040 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 368RAN036105 368RAN060120 374RAN036105 374RAN060120 355(A,C)AV042080 355(A,C)AV060080 353AAV036040 353AAV036060 353AAV036080 353AAV048080 368RAN036105 368RAN060120 374RAN036105 374RAN060120 355AAV042040 368RAN036105 368RAN060120 374RAN036105 374RAN060120 Furnace Model Number 34,400 34,400 34,000 34,200 34,000 34,200 34,400 34,200 34,200 34,200 34,000 33,600 33,800 33,800 33,600 35,200 35,000 34,600 34,800 34,200 34,800 35,000 34,600 34,600 34,600 34,800 35,000 35,000 35,000 35,400 34,800 34,600 34,400 34,600 34,600 34,400 34,800 34,600 34,200 34,400 34,000 33,800 34,200 35,000 34,600 34,600 High 28,400 27,800 28,000 27,400 27,800 27,800 27,800 27,600 28,800 28,200 27,600 27,800 27,200 26,800 27,600 29,000 28,400 28,600 28,000 27,200 29,000 29,200 27,200 27,200 27,200 27,200 28,400 28,600 28,200 29,400 27,600 27,000 26,800 27,200 27,400 27,200 28,600 28,000 28,200 27,600 26,600 26,400 28,000 29,200 27,200 27,200 Low Cooling Capacity 12.3 12.5 12.2 12.3 11.6 12.4 12.3 12.3 12.4 12.2 12.4 12.1 12.2 12.0 11.5 12.6 12.9 12.6 12.7 12.2 12.3 12.8 12.6 12.6 12.7 12.8 12.5 12.6 12.6 12.5 12.6 12.4 12.5 12.5 12.6 12.3 12.5 12.7 12.5 12.5 12.1 12.2 11.7 12.8 12.4 12.7 EER 15.0 15.5 15.0 15.0 13.5 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 13.5 15.5 16.0 15.5 15.5 15.5 15.0 15.5 15.5 15.5 15.5 15.5 16.0 16.0 16.0 15.5 15.5 15.5 15.0 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.0 15.0 14.0 15.5 15.5 15.5 SEER 1,065 1,005 975 1,000 1,050 1,065 1,080 1,055 1,075 1,065 1,005 975 1,000 1,000 1,050 1,065 1,005 975 1,000 1,055 1,080 1,090 1,005 1,020 1,010 1,015 1,090 1,115 1,085 1,230 1,055 1,030 1,010 1,040 1,010 1,000 1,065 1,005 975 1,000 1,030 1,010 1,050 1,090 1,020 1,010 880 765 800 720 840 790 805 770 980 880 765 800 720 675 840 880 765 800 720 725 945 960 670 675 675 675 820 835 795 1,020 725 660 630 665 690 675 880 765 800 720 660 630 840 960 675 675 Low ID CFM High Cooling 226A E Capacity 37,400 36,800 37,000 37,000 37,800 37,000 37,200 37,000 37,200 37,200 36,800 36,800 36,800 37,000 37,600 37,800 37,200 37,200 37,400 37,000 37,600 37,400 37,000 37,000 37,000 37,000 37,400 37,600 37,400 38,000 37,200 37,200 37,200 37,200 37,000 37,200 37,400 37,000 37,000 37,000 37,000 36,800 38,000 37,400 37,000 37,000 High Temp E COP 3.80 3.82 3.72 3.78 3.66 3.80 3.80 3.78 3.78 3.74 3.76 3.68 3.72 3.68 3.62 3.96 3.96 3.88 3.92 3.76 3.86 3.94 3.86 3.88 3.88 3.92 3.94 3.94 3.92 3.98 3.90 3.84 3.84 3.88 3.88 3.80 3.88 3.88 3.80 3.84 3.72 3.72 3.70 3.94 3.88 3.88 8.9 8.8 8.8 8.6 8.5 8.8 8.8 8.8 9.0 8.9 8.7 8.7 8.6 8.5 8.5 9.0 9.0 9.0 8.8 8.7 9.0 9.0 8.7 8.7 8.7 8.8 9.0 9.0 9.0 9.2 8.8 8.6 8.5 8.7 8.7 8.6 9.0 9.0 9.0 8.8 8.5 8.3 8.5 9.0 8.7 8.7 HSPF Low Temp H Capacity 22,600 22,200 22,200 22,200 23,000 22,400 22,400 22,400 22,400 22,600 22,000 22,200 22,200 22,400 23,000 22,800 22,400 22,400 22,400 22,400 22,800 22,400 22,200 22,200 22,200 22,200 22,600 22,600 22,600 23,000 22,400 22,400 22,400 22,400 22,200 22,400 22,600 22,200 22,200 22,200 22,400 22,200 23,200 22,400 22,200 22,200 AHRI Standard Ratings H COP 2.64 2.68 2.62 2.64 2.56 2.66 2.66 2.66 2.66 2.62 2.66 2.60 2.62 2.60 2.54 2.72 2.74 2.68 2.70 2.64 2.66 2.72 2.70 2.70 2.70 2.72 2.72 2.72 2.72 2.72 2.70 2.68 2.68 2.70 2.70 2.66 2.68 2.70 2.66 2.68 2.62 2.62 2.58 2.72 2.70 2.70 21 Model Number 3495188 226ANA036 ---A 3495182 226ANA036 ---A 3495183 226ANA036 ---A 3495184 226ANA036 ---A 3495185 226ANA036 ---A 3495181 226ANA036 ---A 3514366 226ANA036 ---A 3514365 226ANA036 ---A 3495120 226ANA036 ---A 3495121 226ANA036 ---A 3495202 226ANA036 ---A 3495122 226ANA036 ---A 3495123 226ANA036 ---A 3495124 226ANA036 ---A 3495125 226ANA036 ---A 3495126 226ANA036 ---A 3495127 226ANA036 ---A 3495274 226ANA036 ---A 3495275 226ANA036 ---A 3495276 226ANA036 ---A 3495269 226ANA036 ---A 3495270 226ANA036 ---A 3495271 226ANA036 ---A 3495272 226ANA036 ---A 3495273 226ANA036 ---A 3495277 226ANA036 ---A 3495278 226ANA036 ---A 3495279 226ANA036 ---A 3495280 226ANA036 ---A 3495264 226ANA036 ---A 3495265 226ANA036 ---A 3495266 226ANA036 ---A 3495267 226ANA036 ---A 3495268 226ANA036 ---A 3495263 226ANA036 ---A 3514372 226ANA036 ---A 3514373 226ANA036 ---A 3495282 226ANA036 ---A 3495294 226ANA036 ---A 3495295 226ANA036 ---A 3495296 226ANA036 ---A 3495289 226ANA036 ---A 3495290 226ANA036 ---A 3495291 226ANA036 ---A 3495292 226ANA036 ---A 3495293 226ANA036 ---A See notes on pg. 28 AHRI Ref. No. CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A**+TDR CNPV*4824A**+TDR CNPV*4824A**+TDR CNPV*6024A**+TDR CNPV*6024A**+TDR CNPV*6124A**+TDR CNPV*6124A**+TDR CSPH*2412A**+TDR CSPH*3012A**+TDR CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A** CSPH*3612A**+TDR CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** Coil Model Number COMBINATION RATINGS CONTINUED 313*AV024045 313*AV048070 313*AV048090 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 313*AV048070 313*AV048090 313*AV024045 313*AV048070 313*AV048090 315(A,J)AV036070 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV036040 353AAV036060 353AAV036080 353AAV048080 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 374RAN036105 374RAN060120 315(A,J)AV066155 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 368RAN060120 374RAN060120 355(A,C)AV060100 355(A,C)AV060120 Furnace Model Number 34,800 34,600 34,400 34,600 34,600 34,400 34,600 34,400 34,000 34,000 34,200 34,000 34,000 34,000 34,200 34,000 34,200 34,400 34,400 34,800 34,200 34,400 34,400 34,400 34,600 34,800 34,800 34,600 34,800 34,600 34,400 34,400 34,600 34,400 34,200 34,200 34,400 34,200 34,600 34,800 35,000 34,600 34,600 34,800 34,800 34,800 High 27,200 27,000 26,800 27,200 27,400 27,200 28,000 27,600 26,800 27,000 28,000 26,800 26,800 26,800 26,800 28,200 28,400 27,600 28,600 28,800 27,000 27,200 27,200 27,200 27,200 28,200 28,200 28,000 29,200 27,600 27,000 26,600 27,000 27,200 27,200 28,200 27,600 27,800 27,800 29,000 29,000 27,200 27,200 27,200 27,200 27,400 Low Cooling Capacity 12.8 12.4 12.5 12.5 12.6 12.3 12.7 12.5 12.2 12.3 11.7 12.3 12.3 12.4 12.5 12.0 12.4 11.9 12.2 12.6 12.2 12.5 12.5 12.5 12.7 12.5 12.5 12.5 12.5 12.4 12.3 12.3 12.4 12.5 12.2 12.3 12.4 11.6 11.9 12.3 12.7 12.3 12.6 12.6 12.7 12.8 EER 15.5 15.5 15.0 15.0 15.5 15.5 15.5 15.5 15.0 15.0 14.0 15.0 15.0 15.0 15.0 14.5 15.0 15.0 15.0 15.5 15.0 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.0 15.0 15.0 15.5 15.0 15.0 15.0 13.5 15.0 15.0 15.5 15.0 15.5 15.5 15.5 15.5 SEER 1,015 1,030 1,010 1,040 1,010 1,000 1,005 1,000 1,040 1,010 1,050 1,005 1,020 1,010 1,015 1,045 1,055 1,075 1,045 1,060 1,005 1,005 1,020 1,010 1,015 1,065 1,080 1,055 1,080 1,055 1,030 1,010 1,040 1,010 1,000 975 1,000 1,050 1,080 1,060 1,070 1,005 1,005 1,020 1,010 1,015 226A 675 660 630 665 690 675 765 720 665 690 840 670 675 675 675 915 925 745 915 925 660 670 675 675 675 790 805 770 980 725 660 630 665 690 675 800 720 840 750 925 935 660 670 675 675 675 Low ID CFM High Cooling E Capacity 37,000 37,200 37,200 37,200 37,000 37,200 37,000 37,000 37,000 36,800 38,000 36,800 36,800 36,800 36,800 37,200 37,000 37,800 37,400 37,200 37,200 37,000 37,000 37,000 37,000 37,200 37,400 37,200 37,400 37,200 37,200 37,000 37,200 37,000 37,200 37,000 37,000 37,800 37,800 37,600 37,400 37,200 37,000 37,200 37,000 37,000 High Temp E COP 3.92 3.84 3.84 3.88 3.88 3.80 3.88 3.84 3.76 3.74 3.70 3.74 3.76 3.76 3.78 3.70 3.80 3.74 3.78 3.88 3.78 3.82 3.82 3.82 3.86 3.86 3.86 3.86 3.86 3.84 3.80 3.80 3.82 3.82 3.76 3.74 3.78 3.68 3.78 3.84 3.92 3.80 3.86 3.86 3.88 3.90 8.8 8.6 8.6 8.7 8.7 8.6 9.0 8.8 8.5 8.6 8.5 8.5 8.5 8.5 8.5 8.8 9.0 8.5 8.8 9.0 8.5 8.6 8.6 8.6 8.6 8.8 9.0 8.8 9.0 8.7 8.5 8.7 8.6 8.7 8.5 8.8 8.7 8.5 8.6 9.0 9.0 8.5 8.6 8.6 8.6 8.7 HSPF Low Temp H Capacity 22,200 22,400 22,400 22,400 22,200 22,400 22,200 22,200 22,400 22,200 23,200 22,200 22,200 22,200 22,000 22,600 22,200 23,000 22,600 22,400 22,400 22,200 22,400 22,200 22,200 22,400 22,600 22,400 22,600 22,600 22,600 22,400 22,400 22,200 22,400 22,200 22,400 23,000 23,000 22,800 22,400 22,400 22,200 22,400 22,200 22,200 AHRI Standard Ratings H COP 2.72 2.68 2.68 2.70 2.70 2.66 2.70 2.68 2.64 2.64 2.58 2.64 2.64 2.64 2.66 2.60 2.66 2.60 2.64 2.70 2.64 2.66 2.68 2.68 2.70 2.68 2.68 2.68 2.68 2.68 2.64 2.64 2.66 2.66 2.62 2.62 2.66 2.56 2.62 2.66 2.72 2.66 2.68 2.68 2.70 2.72 22 CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A** CSPH*4212A**+TDR CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A**+TDR †FV4CN(B,F)005 FV4CNB006 CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A** CAP**4817A**+TDR CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A** CAP**4821A**+TDR CAP**4823A** 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 226ANA036 ---A 3495297 3495284 3495285 3495286 3495287 3495288 3495283 3514374 3514375 3495298 3495305 3495306 3495300 3495301 3495302 3495303 3495304 3495299 3514376 3495321 3495352 226ANA048 ---A 3495354 226ANA048 ---A 3494783 226ANA048 ---A 3494784 226ANA048 ---A 3494785 226ANA048 ---A 3494786 226ANA048 ---A 3494781 226ANA048 ---A 3494782 226ANA048 ---A 3514378 226ANA048 ---A 3514377 226ANA048 ---A 3494788 226ANA048 ---A 3494808 226ANA048 ---A 3494809 226ANA048 ---A 3494810 226ANA048 ---A 3494811 226ANA048 ---A 3494812 226ANA048 ---A 3494813 226ANA048 ---A 3494814 226ANA048 ---A 3494805 226ANA048 ---A 3494806 226ANA048 ---A 3494807 226ANA048 ---A 3514380 226ANA048 ---A 3514379 226ANA048 ---A 3494816 226ANA048 ---A 3494821 226ANA048 ---A See notes on pg. 28 Coil Model Number Model Number AHRI Ref. No. COMBINATION RATINGS CONTINUED 359BAV060080 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 315(A,J)AV048090 315(A,J)AV060110 353AAV048080 353AAV060100 355(A,C)AV060080 355(A,C)AV060100 368RAN060120 374RAN060120 315(A,J)AV036070 315(A,J)AV048090 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 374RAN036105 353AAV036040 355(A,C)AV042060 355(A,C)AV042080 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 355AAV042040 374RAN036105 374RAN060120 Furnace Model Number 47,000 48,000 46,000 46,000 46,500 46,500 46,000 46,000 46,000 46,000 46,000 45,500 46,000 46,000 46,000 46,000 46,000 46,000 45,500 46,000 46,000 46,000 45,500 45,500 46,000 35,000 34,800 34,600 34,600 34,800 34,600 34,400 34,400 34,600 34,400 34,600 34,800 35,000 34,800 34,800 35,000 34,800 34,600 34,600 34,400 High 39,000 39,500 36,400 36,400 38,500 39,000 36,400 38,000 38,500 38,500 38,000 36,000 36,200 36,200 36,200 38,000 37,800 39,000 36,000 37,600 36,200 38,500 38,500 37,600 38,500 28,400 27,800 27,200 26,800 27,200 27,400 27,200 28,200 27,600 28,000 27,200 27,400 27,800 27,200 26,800 27,200 27,600 27,400 28,400 28,200 Low Cooling Capacity 12.5 12.9 12.0 12.0 11.9 12.2 11.9 11.8 12.1 11.9 11.7 11.9 12.0 12.2 12.3 11.8 12.2 12.3 11.8 11.8 12.0 12.1 11.9 11.6 11.7 12.7 12.5 12.4 12.4 12.5 12.6 12.3 12.4 12.5 11.7 12.4 12.6 12.6 12.4 12.5 12.5 12.7 12.4 12.5 11.7 EER 16.0 16.0 15.0 15.0 15.0 15.5 15.0 15.0 15.0 15.0 14.0 15.0 15.0 15.0 15.0 15.0 15.5 15.5 15.0 15.0 15.0 15.0 15.0 13.5 15.0 16.0 15.5 15.0 15.0 15.5 15.5 15.5 15.5 15.5 13.5 15.0 15.5 15.5 15.0 15.5 15.5 15.5 15.0 15.5 13.5 SEER 1,400 1,400 1,345 1,355 1,415 1,365 1,310 1,395 1,350 1,355 1,400 1,345 1,355 1,355 1,365 1,430 1,385 1,400 1,310 1,395 1,360 1,350 1,355 1,400 1,470 1,075 1,055 1,030 1,010 1,040 1,010 1,000 975 1,000 1,050 1,005 1,005 1,055 1,030 1,010 1,040 1,010 1,000 975 1,050 1,120 1,120 835 850 1,095 1,210 840 1,040 1,170 1,155 1,120 835 850 845 845 1,105 1,050 1,240 840 1,040 845 1,170 1,155 1,120 1,160 800 725 660 630 665 690 675 800 720 840 660 670 725 660 630 665 690 675 800 840 Low ID CFM High Cooling 226A 48,000 48,000 48,000 48,000 48,500 48,000 48,000 48,500 48,000 48,500 48,500 48,000 48,000 48,000 47,500 48,500 48,000 48,000 48,000 48,500 48,000 48,000 48,000 48,500 48,500 E Capacity 37,400 37,400 37,400 37,200 37,200 37,000 37,200 37,000 37,000 38,000 37,200 37,200 37,400 37,400 37,200 37,400 37,200 37,200 37,200 38,000 High Temp 3.60 3.74 3.54 3.54 3.54 3.58 3.50 3.52 3.56 3.52 3.50 3.50 3.52 3.54 3.56 3.50 3.54 3.58 3.46 3.48 3.50 3.52 3.50 3.44 3.50 E COP 3.92 3.88 3.84 3.84 3.86 3.86 3.80 3.78 3.82 3.72 3.84 3.88 3.90 3.86 3.86 3.90 3.88 3.82 3.82 3.74 9.1 9.3 8.6 8.6 9.0 9.0 8.5 8.8 9.0 9.0 8.7 8.5 8.5 8.5 8.6 9.0 9.0 9.0 8.5 8.8 8.5 8.9 8.8 8.5 9.0 9.0 8.8 8.6 8.5 8.6 8.7 8.6 8.9 8.7 8.5 8.6 8.7 8.8 8.6 8.5 8.6 8.8 8.6 9.0 8.5 HSPF Low Temp 29,400 29,800 29,600 29,600 30,200 29,600 29,600 30,000 29,600 29,800 30,200 29,400 29,400 29,200 29,200 29,800 29,400 29,400 29,400 29,800 29,400 29,200 29,400 30,000 30,200 H Capacity 22,600 22,600 22,600 22,400 22,400 22,200 22,400 22,400 22,400 23,200 22,400 22,400 22,600 22,600 22,400 22,600 22,400 22,400 22,400 23,200 AHRI Standard Ratings 2.80 2.90 2.72 2.74 2.74 2.76 2.70 2.72 2.74 2.72 2.70 2.70 2.72 2.74 2.76 2.70 2.74 2.76 2.68 2.68 2.72 2.72 2.70 2.66 2.70 H COP 2.72 2.70 2.66 2.66 2.68 2.68 2.64 2.64 2.66 2.58 2.66 2.70 2.70 2.68 2.68 2.70 2.70 2.66 2.66 2.58 23 Model Number 3494822 226ANA048 ---A 3494835 226ANA048 ---A 3494836 226ANA048 ---A 3494837 226ANA048 ---A 3494838 226ANA048 ---A 3494839 226ANA048 ---A 3494832 226ANA048 ---A 3494833 226ANA048 ---A 3494834 226ANA048 ---A 3514382 226ANA048 ---A 3514381 226ANA048 ---A 3494841 226ANA048 ---A 3494845 226ANA048 ---A 3494846 226ANA048 ---A 3494847 226ANA048 ---A 3494848 226ANA048 ---A 3494849 226ANA048 ---A 3494850 226ANA048 ---A 3494851 226ANA048 ---A 3494842 226ANA048 ---A 3494843 226ANA048 ---A 3494844 226ANA048 ---A 3514384 226ANA048 ---A 3514383 226ANA048 ---A 3494863 226ANA048 ---A 3494868 226ANA048 ---A 3494869 226ANA048 ---A 3494870 226ANA048 ---A 3494871 226ANA048 ---A 3494872 226ANA048 ---A 3494865 226ANA048 ---A 3494866 226ANA048 ---A 3494867 226ANA048 ---A 3514386 226ANA048 ---A 3514385 226ANA048 ---A 3494883 226ANA048 ---A 3494885 226ANA048 ---A 3494938 226ANA048 ---A 3494939 226ANA048 ---A 3494940 226ANA048 ---A 3494941 226ANA048 ---A 3494948 226ANA048 ---A 3494949 226ANA048 ---A 3494950 226ANA048 ---A 3494951 226ANA048 ---A 3494942 226ANA048 ---A See notes on pg. 28 AHRI Ref. No. CAP**4823A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A** CAP**4824A**+TDR CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A**+TDR CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A**+TDR CAP**6025A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** Coil Model Number COMBINATION RATINGS CONTINUED 359BAV060100 313*AV048070 313*AV048090 313*AV060110 313*AV060135 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 359BAV060100 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 Furnace Model Number 46,000 46,000 46,000 46,000 46,000 46,500 45,500 46,000 46,000 46,000 45,500 45,500 46,500 47,000 47,000 47,000 47,000 47,000 47,500 46,500 47,000 47,000 47,000 46,500 46,500 47,000 47,000 47,000 47,000 47,500 46,500 47,000 47,000 47,000 46,500 46,500 47,000 46,000 46,500 46,500 46,500 46,000 46,000 46,000 46,500 46,500 High 38,000 36,200 36,200 36,200 38,000 39,000 36,000 37,600 36,200 38,500 38,500 37,600 36,400 36,600 36,600 36,600 38,500 38,500 39,500 36,400 38,000 36,400 39,000 39,000 38,000 36,600 36,600 36,600 38,500 39,500 36,400 38,000 36,400 39,000 39,000 38,000 38,500 38,000 38,500 39,500 39,000 36,200 36,400 36,400 36,400 37,800 Low Cooling Capacity 11.9 12.1 12.3 12.4 12.2 12.3 11.9 11.9 12.0 12.2 12.0 11.6 12.2 12.3 12.5 12.6 12.1 12.4 12.5 12.1 12.0 12.3 12.4 12.2 11.8 12.3 12.5 12.6 12.5 12.5 12.1 12.1 12.3 12.4 12.2 11.8 12.2 11.3 12.1 12.4 12.2 12.1 12.2 12.3 12.4 11.9 EER 15.0 15.0 15.0 15.5 15.5 15.5 15.0 15.0 15.0 15.0 15.0 13.5 15.0 15.5 15.5 15.5 15.0 15.5 15.5 15.0 15.5 15.5 15.5 15.0 14.0 15.5 15.5 15.5 16.0 16.0 15.0 15.5 15.5 15.5 15.0 14.0 15.5 14.5 15.5 15.0 15.0 15.0 15.0 15.5 15.5 15.5 SEER 1,405 1,355 1,355 1,365 1,410 1,425 1,310 1,395 1,360 1,350 1,355 1,400 1,345 1,355 1,355 1,365 1,445 1,405 1,420 1,310 1,395 1,360 1,350 1,355 1,400 1,355 1,355 1,365 1,410 1,425 1,310 1,395 1,360 1,350 1,355 1,400 1,430 1,455 1,420 1,380 1,400 1,345 1,355 1,355 1,365 1,450 226A 1,105 850 845 845 1,070 1,260 840 1,040 845 1,170 1,155 1,120 835 850 845 845 1,115 1,065 1,255 840 1,040 845 1,170 1,155 1,120 850 845 845 1,070 1,260 840 1,040 845 1,170 1,155 1,120 1,120 1,090 1,105 1,375 1,235 835 850 845 845 1,020 Low ID CFM High Cooling E Capacity 48,000 48,000 47,500 47,500 48,000 48,000 48,000 48,000 48,000 48,000 48,000 48,500 48,000 48,000 48,000 48,000 48,500 48,000 48,000 48,000 48,500 48,000 48,000 48,000 48,500 48,000 48,000 48,000 48,000 48,000 48,000 48,500 48,000 48,000 48,000 48,500 48,500 49,000 48,000 48,000 48,000 48,000 48,000 47,500 47,500 48,500 High Temp E COP 3.50 3.52 3.56 3.58 3.56 3.60 3.48 3.50 3.52 3.54 3.50 3.44 3.54 3.56 3.60 3.62 3.56 3.60 3.62 3.50 3.54 3.56 3.56 3.54 3.48 3.56 3.60 3.62 3.62 3.64 3.52 3.54 3.56 3.58 3.54 3.48 3.56 3.40 3.54 3.58 3.56 3.52 3.54 3.56 3.58 3.52 8.8 8.5 8.5 8.6 9.0 9.1 8.5 8.8 8.5 9.0 8.9 8.5 8.6 8.7 8.7 8.7 9.1 9.2 9.2 8.6 9.0 8.7 9.1 9.0 8.7 8.7 8.7 8.7 9.1 9.3 8.6 9.0 8.7 9.0 9.0 8.7 9.1 8.8 9.0 9.0 9.0 8.5 8.5 8.5 8.6 9.0 HSPF Low Temp H Capacity 29,800 29,400 29,200 29,200 29,400 29,400 29,200 29,600 29,400 29,200 29,400 30,000 29,600 29,600 29,400 29,400 30,200 30,000 29,800 29,600 30,000 29,800 29,400 29,600 30,200 29,600 29,400 29,400 29,800 29,800 29,600 30,000 29,800 29,400 29,600 30,200 30,400 30,600 29,600 29,200 29,400 29,400 29,400 29,200 29,200 30,000 AHRI Standard Ratings H COP 2.70 2.72 2.76 2.76 2.76 2.78 2.68 2.70 2.72 2.72 2.70 2.66 2.76 2.78 2.80 2.82 2.76 2.82 2.82 2.72 2.74 2.76 2.76 2.74 2.70 2.78 2.80 2.82 2.80 2.82 2.72 2.74 2.76 2.78 2.76 2.70 2.80 2.64 2.74 2.76 2.74 2.72 2.74 2.76 2.78 2.72 24 Model Number 3494943 226ANA048 ---A 3494944 226ANA048 ---A 3494945 226ANA048 ---A 3494946 226ANA048 ---A 3494947 226ANA048 ---A 3514399 226ANA048 ---A 3494937 226ANA048 ---A 3494957 226ANA048 ---A 3494958 226ANA048 ---A 3494959 226ANA048 ---A 3494960 226ANA048 ---A 3494964 226ANA048 ---A 3494965 226ANA048 ---A 3494966 226ANA048 ---A 3494967 226ANA048 ---A 3494954 226ANA048 ---A 3494955 226ANA048 ---A 3494956 226ANA048 ---A 3494961 226ANA048 ---A 3494962 226ANA048 ---A 3494963 226ANA048 ---A 3514400 226ANA048 ---A 3494953 226ANA048 ---A 3494984 226ANA048 ---A 3494985 226ANA048 ---A 3494986 226ANA048 ---A 3494987 226ANA048 ---A 3494989 226ANA048 ---A 3514408 226ANA048 ---A 3514409 226ANA048 ---A 3514410 226ANA048 ---A 3494981 226ANA048 ---A 3494982 226ANA048 ---A 3494983 226ANA048 ---A 3494988 226ANA048 ---A 3514407 226ANA048 ---A 3494980 226ANA048 ---A 3514401 226ANA048 ---A 3495001 226ANA048 ---A 3495166 226ANA048 ---A 3495167 226ANA048 ---A 3495168 226ANA048 ---A 3495169 226ANA048 ---A 3495176 226ANA048 ---A 3495177 226ANA048 ---A 3495178 226ANA048 ---A See notes on pg. 28 AHRI Ref. No. CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A** CNPH*4821A**+TDR CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A**+TDR CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A**+TDR CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** Coil Model Number COMBINATION RATINGS CONTINUED 313*AV048070 313*AV048090 313*AV060110 313*AV060135 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 313*AV048070 313*AV048090 313*AV060110 313*AV060135 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 374RAN060120 313*AV048070 313*AV048090 313*AV060110 313*AV060135 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 374RAN060120 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 374RAN060120 Furnace Model Number 46,500 46,500 45,500 46,000 46,000 46,000 46,000 46,500 47,000 47,000 47,000 46,500 47,000 47,000 47,000 47,000 47,000 47,500 46,500 47,000 47,000 46,500 46,500 47,000 47,500 47,000 47,000 47,000 47,000 47,000 47,500 47,500 47,500 47,500 46,500 47,000 47,000 47,000 48,000 46,000 46,500 46,500 46,500 46,000 46,000 46,000 High 39,500 39,000 36,200 37,800 36,200 38,500 38,000 38,500 38,500 40,000 39,500 36,400 36,600 36,600 36,600 39,000 38,500 39,500 36,400 38,000 36,600 39,000 38,500 38,500 39,000 40,000 39,500 38,000 39,500 39,500 39,500 39,000 38,500 39,500 36,600 39,000 39,000 39,000 38,500 38,000 38,500 39,500 39,000 36,200 36,400 36,400 Low Cooling Capacity 12.3 12.4 12.0 11.9 12.1 12.1 11.6 11.5 12.3 12.6 12.4 12.3 12.4 12.5 12.7 12.1 12.5 12.6 12.2 12.1 12.3 12.3 11.8 11.5 12.3 12.6 12.4 12.3 12.4 12.5 12.6 12.1 12.5 12.6 12.1 12.1 12.3 12.2 11.8 11.3 12.1 12.4 12.2 12.1 12.2 12.3 EER 15.0 15.5 15.0 15.0 15.0 15.0 14.5 15.0 15.5 15.5 15.5 15.5 15.5 15.5 16.0 15.5 16.0 16.0 15.0 15.5 15.5 15.5 15.0 15.0 15.5 15.5 15.5 15.5 15.5 16.0 16.0 15.5 16.0 16.0 15.0 15.0 15.5 15.5 14.0 14.5 15.5 15.0 15.5 15.0 15.0 15.5 SEER 1,410 1,425 1,310 1,395 1,360 1,355 1,400 1,465 1,430 1,395 1,420 1,345 1,355 1,355 1,365 1,455 1,425 1,440 1,310 1,395 1,360 1,355 1,400 1,445 1,410 1,370 1,390 1,345 1,355 1,355 1,365 1,445 1,400 1,420 1,310 1,395 1,360 1,355 1,680 1,455 1,420 1,380 1,400 1,345 1,355 1,355 1,405 1,260 840 1,040 845 1,155 1,120 1,100 1,115 1,390 1,255 835 850 845 845 1,130 1,085 1,275 840 1,040 845 1,155 1,120 1,080 1,095 1,370 1,220 1,005 1,190 1,185 1,175 1,110 1,060 1,250 840 1,145 1,175 1,155 1,120 1,090 1,105 1,375 1,235 835 850 845 Low ID CFM High Cooling 226A E Capacity 48,000 48,000 48,000 48,000 48,000 48,000 48,500 49,000 48,500 48,000 48,000 48,000 48,000 48,000 47,500 48,500 48,000 48,000 48,000 48,500 48,000 48,000 48,500 49,500 48,500 48,000 48,500 48,500 48,500 48,000 48,000 49,000 48,500 48,500 48,000 48,500 48,500 48,500 50,000 49,000 48,000 48,000 48,000 48,000 48,000 47,500 High Temp E COP 3.58 3.60 3.48 3.50 3.52 3.50 3.44 3.44 3.58 3.62 3.60 3.54 3.56 3.60 3.62 3.56 3.62 3.64 3.52 3.54 3.56 3.54 3.48 3.48 3.62 3.64 3.62 3.58 3.60 3.64 3.66 3.60 3.64 3.68 3.54 3.56 3.60 3.58 3.60 3.40 3.54 3.58 3.56 3.52 3.54 3.56 9.0 9.1 8.5 9.0 8.6 8.8 8.8 9.0 9.1 9.2 9.2 8.7 8.7 8.7 8.8 9.1 9.2 9.3 8.6 9.0 8.7 9.0 9.0 9.0 9.1 9.2 9.2 9.0 9.1 9.2 9.2 9.1 9.2 9.4 8.6 9.0 9.0 9.1 9.0 8.8 9.0 9.0 9.0 8.6 8.6 8.6 HSPF Low Temp H Capacity 29,400 29,400 29,400 29,800 29,400 29,400 30,000 31,000 30,000 29,600 30,000 29,600 29,600 29,400 29,600 30,200 30,000 29,800 29,400 30,200 29,600 29,600 30,200 31,000 30,000 29,600 29,800 29,800 29,600 29,600 29,400 30,400 30,200 30,200 29,600 30,200 29,800 29,800 31,400 30,600 29,600 29,200 29,400 29,400 29,400 29,200 AHRI Standard Ratings H COP 2.76 2.78 2.70 2.70 2.72 2.72 2.66 2.70 2.80 2.82 2.82 2.76 2.78 2.80 2.84 2.78 2.84 2.84 2.74 2.76 2.78 2.76 2.70 2.70 2.80 2.82 2.80 2.76 2.78 2.80 2.82 2.78 2.84 2.86 2.74 2.76 2.78 2.76 2.76 2.64 2.74 2.76 2.74 2.72 2.74 2.76 25 Model Number 3495179 226ANA048 ---A 3495170 226ANA048 ---A 3495171 226ANA048 ---A 3495172 226ANA048 ---A 3495173 226ANA048 ---A 3495174 226ANA048 ---A 3495175 226ANA048 ---A 3514392 226ANA048 ---A 3514391 226ANA048 ---A 3495165 226ANA048 ---A 3495191 226ANA048 ---A 3495192 226ANA048 ---A 3495193 226ANA048 ---A 3495199 226ANA048 ---A 3495200 226ANA048 ---A 3495201 226ANA048 ---A 3495194 226ANA048 ---A 3495195 226ANA048 ---A 3495196 226ANA048 ---A 3495197 226ANA048 ---A 3495198 226ANA048 ---A 3514394 226ANA048 ---A 3514393 226ANA048 ---A 3495190 226ANA048 ---A 3495204 226ANA048 ---A 3495205 226ANA048 ---A 3495206 226ANA048 ---A 3495212 226ANA048 ---A 3495213 226ANA048 ---A 3495214 226ANA048 ---A 3495207 226ANA048 ---A 3495208 226ANA048 ---A 3495209 226ANA048 ---A 3495210 226ANA048 ---A 3495211 226ANA048 ---A 3514396 226ANA048 ---A 3514395 226ANA048 ---A 3495203 226ANA048 ---A 3495227 226ANA048 ---A 3495228 226ANA048 ---A 3495229 226ANA048 ---A 3495235 226ANA048 ---A 3495236 226ANA048 ---A 3495237 226ANA048 ---A 3495230 226ANA048 ---A 3495231 226ANA048 ---A See notes on pg. 28 AHRI Ref. No. CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A** CNPV*4821A**+TDR CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A** CNPV*4824A**+TDR CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A** CNPV*6024A**+TDR CNPV*6124A** CNPV*6124A** CNPV*6124A** CNPV*6124A** CNPV*6124A** CNPV*6124A** CNPV*6124A** CNPV*6124A** Coil Model Number COMBINATION RATINGS CONTINUED 313*AV048090 313*AV060110 313*AV060135 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV060100 353AAV060120 313*AV048090 313*AV060110 313*AV060135 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 313*AV048090 313*AV060110 313*AV060135 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 315(A,J)AV066155 353AAV048080 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 Furnace Model Number 46,500 46,500 46,500 46,500 45,500 46,000 46,000 46,000 46,000 46,000 46,500 46,500 46,500 46,000 46,000 46,500 46,500 46,500 45,500 46,000 46,000 46,000 46,000 46,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,500 46,500 47,000 47,000 47,000 46,500 46,500 48,000 48,000 48,000 47,500 47,500 47,500 48,000 48,000 High 36,400 37,800 39,500 39,000 36,200 37,800 36,200 38,500 38,500 38,000 38,500 39,500 39,000 36,400 36,400 36,400 39,500 39,000 36,200 37,800 36,200 38,500 38,500 38,000 38,500 40,000 39,500 36,600 36,600 36,600 40,000 39,500 36,400 38,000 36,600 39,000 39,000 38,500 39,500 40,500 40,000 37,000 37,000 37,000 40,500 40,000 Low Cooling Capacity 12.4 11.9 12.3 12.4 12.0 11.9 12.1 12.2 12.1 11.6 12.1 12.4 12.2 12.2 12.3 12.4 12.3 12.4 12.0 11.9 12.1 12.2 12.1 11.6 12.3 12.6 12.4 12.4 12.5 12.7 12.5 12.6 12.2 12.1 12.3 12.4 12.3 11.8 12.5 12.7 12.6 12.6 12.7 12.8 12.6 12.7 EER 15.5 15.5 15.0 15.5 15.0 15.0 15.0 15.0 15.0 14.5 15.5 15.0 15.0 15.0 15.5 15.5 15.0 15.5 15.0 15.0 15.0 15.0 15.0 15.0 15.5 15.5 15.5 15.5 15.5 16.0 15.5 16.0 15.0 15.5 15.5 15.5 15.5 15.0 16.0 15.5 16.0 16.0 16.0 16.0 15.5 16.0 SEER 1,365 1,450 1,410 1,425 1,310 1,395 1,360 1,350 1,355 1,400 1,420 1,380 1,400 1,355 1,355 1,365 1,410 1,425 1,310 1,395 1,360 1,350 1,355 1,400 1,430 1,395 1,420 1,355 1,355 1,365 1,425 1,440 1,310 1,395 1,360 1,350 1,355 1,400 1,435 1,400 1,425 1,355 1,355 1,365 1,430 1,445 226A 845 1,020 1,405 1,260 840 1,040 845 1,170 1,155 1,120 1,105 1,375 1,235 850 845 845 1,405 1,260 840 1,040 845 1,170 1,155 1,120 1,115 1,390 1,255 850 845 845 1,420 1,275 840 1,040 845 1,170 1,155 1,120 1,125 1,405 1,265 850 845 845 1,425 1,285 Low ID CFM High Cooling E Capacity 47,500 48,500 48,000 48,000 48,000 48,000 48,000 47,500 48,000 48,500 48,000 48,000 48,000 48,000 47,500 47,500 48,000 48,000 48,000 48,000 48,000 47,500 48,000 48,500 48,500 48,000 48,000 48,000 48,000 47,500 48,000 48,000 48,000 48,500 48,000 48,000 48,000 48,500 48,500 48,500 48,500 48,000 48,000 48,000 48,500 48,500 High Temp E COP 3.58 3.52 3.58 3.60 3.48 3.50 3.52 3.54 3.50 3.44 3.54 3.58 3.56 3.54 3.56 3.58 3.58 3.60 3.48 3.50 3.52 3.54 3.50 3.44 3.58 3.62 3.60 3.56 3.60 3.62 3.60 3.64 3.52 3.54 3.56 3.58 3.54 3.48 3.66 3.70 3.68 3.66 3.68 3.72 3.70 3.72 8.8 8.8 9.0 9.1 8.6 8.6 8.6 9.0 8.9 8.8 9.0 9.0 9.0 8.5 8.6 8.6 9.0 9.1 8.5 9.0 8.5 9.0 8.8 8.8 9.1 9.2 9.2 8.7 8.7 8.7 9.2 9.2 8.6 8.6 8.7 9.0 9.0 9.0 9.3 9.5 9.5 9.0 9.0 9.0 9.5 9.5 HSPF Low Temp H Capacity 29,200 30,000 29,400 29,400 29,400 29,800 29,400 29,200 29,400 30,000 29,600 29,200 29,400 29,400 29,200 29,200 29,400 29,400 29,400 29,800 29,400 29,200 29,400 30,000 30,000 29,600 30,000 29,600 29,400 29,400 29,800 29,800 29,400 30,200 29,600 29,400 29,600 30,200 30,400 30,000 30,200 30,000 30,000 29,800 30,200 30,200 AHRI Standard Ratings H COP 2.78 2.72 2.76 2.78 2.70 2.70 2.72 2.74 2.72 2.66 2.74 2.76 2.74 2.74 2.76 2.78 2.76 2.78 2.70 2.70 2.72 2.74 2.72 2.66 2.80 2.82 2.82 2.78 2.80 2.82 2.80 2.84 2.74 2.76 2.78 2.78 2.76 2.70 2.84 2.88 2.86 2.84 2.88 2.88 2.86 2.88 26 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 226ANA048 ---A 3495232 3495233 3495234 3514398 3514397 3495226 3495310 3495311 3495312 3495313 3495317 3495318 3495319 3495320 3495307 3495308 3495309 3495314 3495315 3495316 3514402 3495322 3495326 3495327 3495328 3495329 3495333 3495334 3495335 3495336 3495323 3495324 3495325 3495330 3495331 3495332 3514403 3495348 3495355 226ANA060 ---A 3494852 226ANA060 ---A 3494854 226ANA060 ---A 3494860 226ANA060 ---A 3494861 226ANA060 ---A 3494862 226ANA060 ---A 3494855 226ANA060 ---A See notes on pg. 28 Model Number AHRI Ref. No. †FV4CNB006 CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CNPV*6124A** CNPV*6124A** CNPV*6124A** CNPV*6124A** CNPV*6124A** CNPV*6124A**+TDR CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A** CSPH*4812A**+TDR CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A** CSPH*6012A**+TDR Coil Model Number COMBINATION RATINGS CONTINUED 313*AV060110 313*AV060135 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 313*AV048070 313*AV048090 313*AV060110 313*AV060135 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 374RAN060120 313*AV048070 313*AV048090 313*AV060110 313*AV060135 315(A,J)AV048090 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 374RAN060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 Furnace Model Number 56,500 55,500 55,000 55,500 55,500 55,500 54,500 47,000 47,500 47,500 47,500 47,500 47,000 46,000 46,500 46,500 46,500 46,500 46,500 46,500 46,500 46,500 46,500 46,500 46,000 46,500 46,500 46,500 47,000 47,000 47,500 47,500 47,500 47,000 47,000 47,000 47,500 47,500 47,500 47,500 46,500 47,000 47,000 47,000 48,000 High 46,500 45,500 45,000 44,500 44,500 44,500 44,000 36,800 38,500 37,000 39,500 39,500 39,000 38,000 38,500 39,500 39,000 38,000 38,000 38,000 38,000 38,500 38,500 39,500 37,800 38,000 38,000 38,500 38,000 38,500 39,000 40,500 40,000 38,500 38,500 38,500 38,500 39,000 39,000 40,000 38,500 38,500 38,500 39,000 38,500 Low Cooling Capacity 12.6 12.2 12.1 11.9 12.2 12.3 11.8 12.3 12.3 12.5 12.6 12.4 11.9 11.3 12.2 12.4 12.2 12.1 12.1 12.3 12.4 12.0 12.3 12.4 12.0 11.9 12.1 12.0 11.7 11.6 12.4 12.7 12.5 12.4 12.5 12.6 12.7 12.2 12.5 12.6 12.2 12.2 12.4 12.3 11.8 EER 16.0 15.0 15.0 15.0 15.0 15.5 15.0 15.5 15.5 16.0 16.0 15.5 15.5 14.5 15.5 15.0 15.0 15.5 15.5 15.5 15.5 15.0 15.5 15.5 15.0 15.0 15.5 15.0 14.0 15.0 15.5 15.5 16.0 15.5 15.5 16.0 16.0 15.5 16.0 16.0 15.5 15.5 15.5 15.5 14.0 SEER 1,750 1,670 1,635 1,695 1,685 1,705 1,585 1,310 1,395 1,360 1,350 1,355 1,400 1,425 1,390 1,340 1,360 1,345 1,355 1,355 1,365 1,425 1,380 1,395 1,310 1,395 1,360 1,355 1,600 1,465 1,430 1,395 1,420 1,345 1,355 1,355 1,365 1,460 1,425 1,440 1,310 1,395 1,360 1,355 1,680 1,400 1,335 1,255 1,190 1,185 1,175 1,130 840 1,040 845 1,170 1,155 1,120 1,070 1,080 1,345 1,200 1,005 1,020 1,010 1,015 1,100 1,045 1,235 1,010 1,040 1,010 1,155 1,120 1,095 1,105 1,390 1,250 1,005 1,020 1,010 1,015 1,125 1,075 1,270 1,010 1,040 1,010 1,155 1,120 Low ID CFM High Cooling 226A 59,000 59,000 59,000 59,000 59,000 59,000 59,000 E Capacity 48,000 48,500 48,500 48,000 48,500 49,000 49,000 48,000 48,000 48,000 48,000 48,000 48,000 48,000 48,500 48,000 48,000 48,000 48,500 48,000 48,000 49,500 49,500 48,500 48,000 48,500 48,000 48,000 48,000 48,000 48,500 48,500 48,500 48,000 48,500 48,000 48,000 50,000 High Temp 3.78 3.64 3.60 3.60 3.64 3.66 3.54 E COP 3.60 3.62 3.64 3.66 3.62 3.56 3.42 3.56 3.58 3.56 3.54 3.54 3.58 3.60 3.54 3.58 3.62 3.50 3.52 3.54 3.52 3.54 3.48 3.62 3.66 3.64 3.58 3.60 3.64 3.66 3.60 3.66 3.68 3.54 3.58 3.60 3.58 3.58 9.5 9.0 8.8 8.8 8.8 9.0 8.7 8.8 9.2 8.8 9.5 9.2 9.2 8.8 9.0 9.1 9.0 8.8 8.8 8.8 9.0 9.0 9.0 9.2 8.8 8.8 8.8 9.0 8.7 9.0 9.2 9.3 9.3 9.0 9.0 9.1 9.0 9.2 9.2 9.5 8.8 9.0 9.0 9.0 8.8 HSPF Low Temp 36,600 36,800 36,800 37,200 36,800 36,800 37,000 H Capacity 30,000 30,400 30,200 30,000 30,200 30,600 30,800 29,600 29,200 29,400 29,600 29,600 29,400 29,400 30,200 29,600 29,600 29,600 30,000 29,600 29,600 31,000 31,200 30,200 29,800 30,200 29,600 29,600 30,000 29,600 30,600 30,200 30,000 29,600 30,400 29,800 29,600 31,400 AHRI Standard Ratings 2.80 2.72 2.70 2.68 2.72 2.74 2.66 H COP 2.80 2.80 2.84 2.84 2.82 2.76 2.66 2.74 2.76 2.74 2.72 2.74 2.76 2.78 2.74 2.76 2.78 2.70 2.72 2.74 2.72 2.74 2.70 2.82 2.84 2.84 2.78 2.80 2.84 2.84 2.80 2.84 2.86 2.74 2.78 2.78 2.78 2.76 27 Model Number 3494853 226ANA060 ---A 3494856 226ANA060 ---A 3494857 226ANA060 ---A 3494858 226ANA060 ---A 3494859 226ANA060 ---A 3514412 226ANA060 ---A 3514411 226ANA060 ---A 3494864 226ANA060 ---A 3494873 226ANA060 ---A 3494874 226ANA060 ---A 3494880 226ANA060 ---A 3494881 226ANA060 ---A 3494882 226ANA060 ---A 3494875 226ANA060 ---A 3494876 226ANA060 ---A 3494877 226ANA060 ---A 3494878 226ANA060 ---A 3494879 226ANA060 ---A 3514414 226ANA060 ---A 3514413 226ANA060 ---A 3494884 226ANA060 ---A 3494886 226ANA060 ---A 3494968 226ANA060 ---A 3494969 226ANA060 ---A 3494976 226ANA060 ---A 3494977 226ANA060 ---A 3494978 226ANA060 ---A 3494970 226ANA060 ---A 3494971 226ANA060 ---A 3494972 226ANA060 ---A 3494973 226ANA060 ---A 3494974 226ANA060 ---A 3494975 226ANA060 ---A 3514421 226ANA060 ---A 3494979 226ANA060 ---A 3494990 226ANA060 ---A 3494991 226ANA060 ---A 3494998 226ANA060 ---A 3494999 226ANA060 ---A 3495000 226ANA060 ---A 3494992 226ANA060 ---A 3494993 226ANA060 ---A 3494994 226ANA060 ---A 3494995 226ANA060 ---A 3494996 226ANA060 ---A 3494997 226ANA060 ---A See notes on pg. 28 AHRI Ref. No. CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A** CAP**6021A**+TDR CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A** CAP**6024A**+TDR CAP**6025A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A** CNPH*6024A**+TDR CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** CNPH*6124A** Coil Model Number COMBINATION RATINGS CONTINUED 313*AV060110 313*AV060135 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 359BAV060100 313*AV060110 313*AV060135 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV048080 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 374RAN060120 313*AV060110 313*AV060135 315(A,J)AV060110 315(A,J)AV066135 315(A,J)AV066155 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 353AAV060100 353AAV060120 355(A,C)AV060080 355(A,C)AV060100 355(A,C)AV060120 368RAN060120 374RAN060120 Furnace Model Number 55,000 55,500 55,000 54,500 55,000 55,000 54,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,500 55,000 55,000 55,000 55,000 54,500 55,500 55,000 55,500 55,500 55,000 55,000 55,000 54,500 55,000 55,500 55,000 54,500 54,500 54,500 55,500 56,000 55,500 55,000 55,500 55,500 55,000 55,500 55,500 54,500 54,500 55,000 High 45,000 45,000 44,500 44,000 44,500 45,500 45,000 45,000 46,000 45,000 44,500 44,500 44,500 46,000 45,000 44,500 44,000 44,500 45,500 45,500 45,000 45,500 46,000 45,000 44,500 44,500 44,500 44,000 46,000 45,500 44,500 44,000 44,500 45,500 45,000 46,000 45,000 45,000 45,000 45,000 44,500 46,000 45,500 44,500 44,500 44,500 Low Cooling Capacity 12.1 12.2 11.3 11.5 11.8 11.9 11.5 11.8 12.2 12.1 12.0 12.2 12.4 12.1 12.3 11.4 11.6 11.8 11.9 11.6 11.8 11.6 12.2 12.1 12.0 12.2 12.3 11.8 12.2 12.3 11.4 11.6 11.9 11.6 11.8 12.3 12.2 12.0 12.2 12.3 11.9 12.2 12.3 11.4 11.5 11.8 EER 14.5 15.0 15.0 14.5 15.0 15.0 14.5 14.0 15.0 15.0 15.0 15.5 15.5 15.0 15.5 14.5 14.5 15.0 15.0 14.5 14.0 14.5 15.0 15.0 15.0 15.5 15.5 15.0 15.0 15.5 14.5 15.0 15.0 14.5 14.0 15.0 15.0 15.0 15.5 15.5 15.0 15.0 15.5 14.5 14.5 15.0 SEER 1,620 1,625 1,730 1,660 1,680 1,735 1,740 1,750 1,685 1,650 1,695 1,685 1,705 1,630 1,640 1,730 1,660 1,680 1,735 1,740 1,750 1,775 1,700 1,670 1,695 1,685 1,705 1,600 1,645 1,655 1,730 1,660 1,680 1,740 1,750 1,675 1,640 1,695 1,685 1,705 1,585 1,625 1,630 1,730 1,660 1,680 226A 1,295 1,270 1,200 1,145 1,175 1,350 1,355 1,400 1,410 1,260 1,190 1,185 1,175 1,430 1,280 1,200 1,145 1,175 1,350 1,355 1,400 1,415 1,425 1,280 1,190 1,185 1,175 1,135 1,440 1,290 1,200 1,145 1,175 1,355 1,400 1,400 1,245 1,190 1,185 1,175 1,125 1,420 1,270 1,200 1,145 1,175 Low ID CFM High Cooling E Capacity 58,500 58,500 60,000 59,500 59,500 59,500 60,000 59,500 59,000 59,000 59,000 59,000 59,000 58,500 58,500 60,000 59,500 59,500 59,500 60,000 59,500 60,000 59,000 59,000 59,000 58,500 58,500 59,000 58,500 58,500 60,000 59,500 59,000 59,500 59,500 59,000 59,000 59,500 59,000 59,000 59,000 59,000 59,000 60,500 60,000 59,500 High Temp E COP 3.60 3.64 3.50 3.50 3.56 3.60 3.54 3.60 3.64 3.62 3.60 3.64 3.68 3.62 3.64 3.50 3.52 3.58 3.60 3.54 3.60 3.58 3.64 3.62 3.60 3.64 3.66 3.54 3.60 3.64 3.50 3.50 3.56 3.54 3.58 3.70 3.66 3.66 3.70 3.72 3.58 3.66 3.68 3.56 3.56 3.62 9.0 9.0 8.8 8.7 8.8 8.8 8.7 8.5 9.0 9.0 8.8 8.8 8.7 9.0 9.0 8.7 8.8 8.8 8.8 8.7 8.7 8.8 9.0 9.0 8.8 8.8 8.8 8.7 9.0 9.0 8.7 8.7 8.8 8.7 8.6 9.0 9.0 9.0 8.8 8.8 8.7 9.0 9.0 8.8 8.7 8.8 HSPF Low Temp H Capacity 36,800 36,600 37,800 37,400 37,200 37,200 37,600 37,200 36,800 36,800 37,000 36,800 36,600 36,800 36,600 37,800 37,400 37,200 37,200 37,600 37,200 37,600 36,800 36,800 37,000 36,600 36,600 36,800 36,600 36,600 37,800 37,400 37,000 37,600 37,200 36,800 36,800 37,200 36,800 36,800 37,000 36,800 36,600 38,000 37,400 37,200 AHRI Standard Ratings H COP 2.70 2.72 2.60 2.62 2.66 2.68 2.64 2.68 2.72 2.70 2.70 2.72 2.74 2.72 2.74 2.60 2.62 2.68 2.68 2.64 2.68 2.66 2.72 2.72 2.70 2.72 2.74 2.66 2.72 2.74 2.60 2.62 2.66 2.64 2.68 2.74 2.72 2.70 2.74 2.76 2.68 2.72 2.74 2.62 2.64 2.68 28 Model Number Coil Model Number 3514422 226ANA060 ---A CNPH*6124A** 3495002 226ANA060 ---A CNPH*6124A**+TDR 3495215 226ANA060 ---A CNPV*6024A** 3495216 226ANA060 ---A CNPV*6024A** 3495222 226ANA060 ---A CNPV*6024A** 3495223 226ANA060 ---A CNPV*6024A** 3495224 226ANA060 ---A CNPV*6024A** 3495217 226ANA060 ---A CNPV*6024A** 3495218 226ANA060 ---A CNPV*6024A** 3495219 226ANA060 ---A CNPV*6024A** 3495220 226ANA060 ---A CNPV*6024A** 3495221 226ANA060 ---A CNPV*6024A** 3514418 226ANA060 ---A CNPV*6024A** 3514417 226ANA060 ---A CNPV*6024A** 3495225 226ANA060 ---A CNPV*6024A**+TDR 3495238 226ANA060 ---A CNPV*6124A** 3495239 226ANA060 ---A CNPV*6124A** 3495245 226ANA060 ---A CNPV*6124A** 3495246 226ANA060 ---A CNPV*6124A** 3495247 226ANA060 ---A CNPV*6124A** 3495240 226ANA060 ---A CNPV*6124A** 3495241 226ANA060 ---A CNPV*6124A** 3495242 226ANA060 ---A CNPV*6124A** 3495243 226ANA060 ---A CNPV*6124A** 3495244 226ANA060 ---A CNPV*6124A** 3514420 226ANA060 ---A CNPV*6124A** 3514419 226ANA060 ---A CNPV*6124A** 3495248 226ANA060 ---A CNPV*6124A**+TDR 3495337 226ANA060 ---A CSPH*6012A** 3495338 226ANA060 ---A CSPH*6012A** 3495345 226ANA060 ---A CSPH*6012A** 3495346 226ANA060 ---A CSPH*6012A** 3495347 226ANA060 ---A CSPH*6012A** 3495339 226ANA060 ---A CSPH*6012A** 3495340 226ANA060 ---A CSPH*6012A** 3495341 226ANA060 ---A CSPH*6012A** 3495342 226ANA060 ---A CSPH*6012A** 3495343 226ANA060 ---A CSPH*6012A** 3495344 226ANA060 ---A CSPH*6012A** 3514423 226ANA060 ---A CSPH*6012A** 3495349 226ANA060 ---A CSPH*6012A**+TDR * Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit. High--- Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43° F (6_C) wb air entering outdoor unit. Low--- Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F ( ---8_C) db 15° F ( ---9_C) wb air entering outdoor unit. AHRI Ref. No. COMBINATION RATINGS CONTINUED High Low Cooling Capacity EER 55,000 45,500 11.6 56,000 45,500 11.9 313*AV060110 55,500 46,000 12.2 313*AV060135 55,500 45,000 12.2 315(A,J)AV060110 55,500 44,500 12.0 315(A,J)AV066135 55,500 44,500 12.3 315(A,J)AV066155 55,500 44,500 12.4 353AAV060100 55,500 46,000 12.2 353AAV060120 55,500 45,500 12.3 355(A,C)AV060080 55,000 44,500 11.4 355(A,C)AV060100 54,500 44,000 11.6 355(A,C)AV060120 55,000 44,500 11.9 368RAN060120 55,000 45,500 11.9 374RAN060120 54,500 45,500 11.6 56,000 45,000 11.7 313*AV060110 56,500 46,500 12.4 313*AV060135 56,000 46,000 12.3 315(A,J)AV060110 56,000 45,000 12.2 315(A,J)AV066135 56,500 45,500 12.4 315(A,J)AV066155 56,500 45,000 12.5 353AAV060100 56,000 46,500 12.4 353AAV060120 56,000 46,000 12.5 355(A,C)AV060080 55,500 45,000 11.6 355(A,C)AV060100 55,500 44,500 11.8 355(A,C)AV060120 56,000 45,000 12.1 368RAN060120 55,500 46,000 12.1 374RAN060120 55,500 46,000 11.8 56,000 47,000 12.0 313*AV060110 56,000 46,000 12.3 313*AV060135 55,500 45,500 12.2 315(A,J)AV060110 55,000 45,000 12.1 315(A,J)AV066135 55,500 45,000 12.3 315(A,J)AV066155 55,500 45,000 12.4 353AAV048080 55,000 44,500 12.0 353AAV060100 55,500 46,000 12.3 353AAV060120 56,000 45,500 12.4 355(A,C)AV060080 54,500 45,000 11.5 355(A,C)AV060100 54,500 44,500 11.6 355(A,C)AV060120 55,000 45,000 11.9 374RAN060120 55,000 45,500 11.7 56,000 45,500 11.9 SEER — Seasonal Energy Efficiency Ratio COP — Coefficient of Performance TDR — Time ---Delay Relay HSPF — Heating Seasonal Performance Factor EER — Energy Efficiency Ratio 374RAN060120 Furnace Model Number 14.5 14.0 15.0 15.0 15.0 15.5 15.5 15.0 15.5 14.5 15.0 15.0 15.0 14.5 14.0 15.5 15.5 15.5 15.5 16.0 15.0 15.5 15.0 15.0 15.5 15.0 15.0 14.5 15.0 15.0 15.0 15.5 15.5 15.0 15.0 15.5 15.0 15.0 15.0 14.5 14.0 SEER 1,740 1,750 1,700 1,670 1,695 1,685 1,705 1,645 1,655 1,730 1,660 1,680 1,735 1,740 2,000 1,710 1,675 1,695 1,685 1,705 1,650 1,660 1,730 1,660 1,680 1,735 1,740 1,750 1,710 1,675 1,695 1,685 1,705 1,605 1,650 1,660 1,730 1,660 1,680 1,740 1,750 High Temp AHRI Standard Ratings Low Temp HSPF E E H H Low Capacity COP Capacity COP 1,355 60,000 3.60 8.7 37,800 2.66 1,400 60,000 3.66 8.7 37,400 2.70 1,425 59,000 3.64 9.0 36,800 2.72 1,280 59,000 3.62 9.0 36,800 2.72 1,190 59,000 3.60 8.8 37,000 2.70 1,185 58,500 3.64 9.0 36,600 2.72 1,175 58,500 3.66 9.0 36,600 2.74 1,440 58,500 3.60 9.0 36,600 2.72 1,290 58,500 3.64 9.0 36,600 2.74 1,200 60,000 3.50 8.8 37,800 2.60 1,145 59,500 3.50 8.8 37,400 2.62 1,175 59,000 3.56 8.8 37,000 2.68 1,350 59,000 3.60 8.8 37,200 2.68 1,355 59,500 3.54 8.7 37,600 2.64 1,400 60,000 3.64 8.5 37,800 2.70 1,430 59,500 3.76 9.2 36,800 2.78 1,290 59,500 3.72 9.1 36,800 2.76 1,190 59,500 3.70 9.0 37,000 2.74 1,185 59,000 3.74 8.7 36,800 2.76 1,175 59,000 3.78 9.0 36,800 2.80 1,445 59,000 3.72 9.1 36,800 2.76 1,300 59,000 3.74 9.2 36,600 2.78 1,200 60,000 3.60 9.0 37,800 2.64 1,145 60,000 3.60 9.0 37,400 2.66 1,175 59,500 3.66 9.0 37,200 2.72 1,350 59,500 3.70 9.0 37,200 2.72 1,355 60,000 3.64 8.8 37,600 2.68 1,680 60,000 3.68 8.8 37,400 2.72 1,425 59,000 3.70 9.0 36,800 2.76 1,275 59,000 3.68 9.0 36,800 2.74 1,190 59,000 3.66 8.8 37,000 2.72 1,185 59,000 3.70 8.8 36,800 2.74 1,175 59,000 3.74 8.8 36,600 2.78 1,130 59,000 3.60 8.7 37,000 2.68 1,440 59,000 3.68 9.0 36,800 2.74 1,290 59,000 3.70 9.0 36,600 2.76 1,200 60,000 3.56 8.8 37,800 2.64 1,145 59,500 3.56 8.5 37,400 2.64 1,175 59,500 3.62 8.7 37,200 2.70 1,355 60,000 3.60 8.7 37,600 2.66 1,400 59,500 3.64 8.7 37,400 2.70 NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up --- to --- date ratings information. ID CFM High Cooling 226A 29 23.44 57 (13.9) 17.75 17.40 57 (13.9) 19.70 67 (19.4) 62 (16.7) 21.90 72 (22.2) 17.98 16.66 57 (13.9) 63 (17.2)†† 17.25 62 (16.7) 19.19 67 (19.4) 17.51 21.35 72 (22.2) 63 (17.2)†† 15.75 57 (13.9) 18.54 67 (19.4) 16.63 20.64 72 (22.2) 62 (16.7) 15.02 57 (13.9) 16.91 16.12 62 (16.7) 63 (17.2)†† 16.39 17.98 67 (19.4) 63 (17.2)†† 20.02 Total 72 (22.2) EWB ° F (° C) 75 (23.9) 23.44 22.97 18.56 19.45 15.83 22.74 21.93 17.82 18.65 15.32 22.33 21.34 17.41 18.21 15.04 21.04 19.59 16.19 16.90 14.15 Sens‡ 17.40 17.16 13.85 14.63 12.01 16.66 16.13 13.10 13.82 11.48 15.75 14.91 12.26 12.91 10.87 15.02 14.02 11.60 12.22 10.37 Sens‡ Capacity MBtuh† 23.98 26.31 67 (19.4) 62 (16.7) 28.91 72 (22.2) 24.28 22.74 57 (13.9) 63 (17.2)†† 23.53 62 (16.7) 25.86 67 (19.4) 23.86 28.43 72 (22.2) 63 (17.2)†† 22.33 57 (13.9) 25.58 67 (19.4) 23.27 28.13 72 (22.2) 62 (16.7) 21.04 57 (13.9) 23.61 22.41 62 (16.7) 63 (17.2)†† 22.75 24.67 63 (17.2)†† 27.16 Total 67 (19.4) See notes on pg. 40 625 560 490 440 CFM 75 (23.9) Capacity MBtuh† 72 (22.2) EWB ° F (° C) EVAPORATOR AIR 800 735 700 600 CFM EVAPORATOR AIR 0.99 0.99 0.99 1.01 1.02 0.98 0.98 0.98 1.00 1.01 0.96 0.97 0.97 0.98 1.00 0.96 0.96 0.97 0.98 0.99 Total System KW** 1.44 1.45 1.45 1.47 1.49 1.43 1.44 1.44 1.46 1.48 1.42 1.43 1.43 1.45 1.47 1.39 1.40 1.41 1.42 1.44 Total System KW** 85 (29.4) 85 (29.4) 22.46 22.27 17.94 18.83 15.23 21.80 21.28 17.22 18.05 14.74 21.43 20.72 16.82 17.62 14.46 20.22 19.02 15.63 16.34 13.63 Sens‡ 16.65 16.84 17.01 18.66 20.76 15.95 16.36 16.59 18.20 20.26 15.10 15.79 16.04 17.60 19.61 14.41 15.31 15.57 17.09 19.05 Total 16.65 16.60 13.37 14.15 11.54 15.95 15.62 12.64 13.36 11.03 15.10 14.47 11.81 12.47 10.43 14.41 13.60 11.20 11.80 9.98 Sens‡ Capacity MBtuh† 22.46 22.80 23.05 24.98 27.45 21.80 22.38 22.67 24.57 27.01 21.43 22.13 22.44 24.32 26.75 20.22 21.34 21.66 23.49 25.86 Total Capacity MBtuh† DETAILED COOLING CAPACITIES# 105 (40.6) Total 1.83 1.83 1.83 1.85 1.87 1.81 1.81 1.82 1.83 1.86 1.80 1.80 1.81 1.83 1.85 1.77 1.78 1.78 1.80 1.82 20.31 20.35 20.40 22.13 24.35 19.76 19.93 20.10 21.81 24.00 19.43 19.70 19.91 21.61 23.79 18.39 19.02 19.29 20.95 23.07 20.31 20.35 16.63 17.52 13.97 19.76 19.81 15.93 16.77 13.50 19.43 19.32 15.56 16.36 13.24 18.39 17.76 14.42 15.14 12.47 95 (35) Sens‡ Total System KW** Total Sens‡ Capacity MBtuh† 105 (40.6) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 21.42 21.51 17.30 18.19 14.61 20.81 20.58 16.58 17.42 14.13 20.46 20.05 16.20 17.00 13.86 19.33 18.42 15.05 15.75 13.06 Capacity MBtuh† 21.42 21.58 21.75 23.59 25.93 20.81 21.17 21.41 23.22 25.54 20.46 20.94 21.20 23.00 25.30 19.33 20.21 20.50 22.25 24.49 1.15 1.15 1.15 1.17 1.18 1.14 1.14 1.15 1.16 1.17 1.13 1.13 1.13 1.15 1.16 1.12 1.12 1.13 1.14 1.15 15.84 15.89 15.99 17.56 19.55 15.19 15.43 15.61 17.15 19.10 14.40 14.89 15.11 16.61 18.51 13.75 14.45 14.69 16.14 18.00 15.84 15.89 12.85 13.65 11.05 15.19 15.08 12.15 12.87 10.55 14.40 13.98 11.35 12.00 9.98 13.75 13.14 10.75 11.36 9.54 1.34 1.34 1.34 1.35 1.36 1.32 1.33 1.33 1.34 1.35 1.31 1.32 1.32 1.33 1.34 1.30 1.31 1.31 1.32 1.33 14.97 15.00 14.90 16.39 18.27 14.37 14.44 14.56 16.03 17.88 13.64 13.94 14.12 15.54 17.35 13.04 13.54 13.74 15.13 16.90 14.97 15.00 12.33 13.11 10.53 14.37 14.44 11.63 12.35 10.05 13.64 13.45 10.86 11.51 9.50 13.04 12.64 10.28 10.88 9.09 226ANA024---A---LO Outdoor Section With FV4CNF002 Indoor Section Total System KW** 1.63 1.63 1.63 1.65 1.67 1.61 1.62 1.62 1.64 1.66 1.60 1.61 1.61 1.63 1.65 1.57 1.58 1.59 1.60 1.63 Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 226ANA024---A---HI Outdoor Section With FV4CNF002 Indoor Section 95 (35) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 226A 1.55 1.55 1.55 1.56 1.57 1.54 1.54 1.54 1.55 1.56 1.53 1.53 1.53 1.54 1.55 1.52 1.52 1.52 1.53 1.54 Total System KW** 2.05 2.05 2.05 2.07 2.09 2.03 2.03 2.03 2.05 2.08 2.02 2.02 2.03 2.05 2.07 1.99 2.00 2.00 2.02 2.05 Total System KW** 115 (46.1) 115 (46.1) 19.14 19.17 15.92 16.81 13.30 18.63 18.67 15.24 16.08 12.85 18.34 18.40 14.87 15.68 12.60 17.38 17.06 13.78 14.50 11.85 Sens‡ 14.03 14.06 13.75 15.16 16.93 13.49 13.52 13.45 14.83 16.57 12.82 12.94 13.07 14.41 16.11 12.27 12.56 12.73 14.04 15.71 Total 14.03 14.06 11.75 12.53 9.98 13.49 13.52 11.08 11.80 9.52 12.82 12.85 10.33 10.99 8.99 12.27 12.07 9.75 10.35 8.59 Sens‡ Capacity MBtuh† 19.14 19.17 18.98 20.61 22.69 18.63 18.67 18.71 20.33 22.38 18.34 18.40 18.55 20.16 22.20 17.38 17.78 18.00 19.57 21.56 Total Capacity MBtuh† 1.80 1.80 1.80 1.81 1.82 1.79 1.79 1.79 1.80 1.81 1.78 1.78 1.78 1.79 1.80 1.77 1.77 1.77 1.78 1.80 Total System KW** 2.30 2.30 2.30 2.32 2.34 2.28 2.28 2.28 2.30 2.33 2.27 2.27 2.27 2.30 2.32 2.24 2.25 2.25 2.27 2.30 Total System KW** 125 (51.7) 125 (51.7) 17.88 17.91 15.16 16.07 12.59 17.42 17.45 14.51 15.36 12.15 17.16 17.19 14.15 14.97 11.91 16.30 16.30 13.11 13.82 11.20 Sens‡ 13.02 13.05 12.52 13.85 15.50 12.54 12.56 12.27 13.57 15.19 11.93 11.96 11.94 13.20 14.79 11.44 11.54 11.64 12.88 14.44 Total 13.02 13.05 11.13 11.92 9.40 12.54 12.56 10.49 11.22 8.96 11.93 11.96 9.75 10.40 8.46 11.44 11.45 9.21 9.81 8.06 Sens‡ Capacity MBtuh† 17.88 17.91 17.47 19.01 20.95 17.42 17.45 17.25 18.76 20.68 17.16 17.19 17.11 18.61 20.52 16.30 16.48 16.64 18.11 19.97 Total Capacity MBtuh† 2.10 2.10 2.10 2.11 2.12 2.09 2.09 2.09 2.10 2.11 2.08 2.08 2.08 2.09 2.10 2.07 2.07 2.07 2.08 2.09 Total System KW** 2.59 2.59 2.58 2.60 2.62 2.57 2.57 2.57 2.59 2.61 2.56 2.56 2.56 2.58 2.60 2.53 2.53 2.53 2.56 2.58 Total System KW** 30 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.00 1.00 1.01 1.00 1.00 CAP**3017A** CAP**3614A** CAP**3617A** CAP**3621A** CNPH*2417A** CNPH*3017A** CNPV*2414A** CNPV*2417A** CNPV*3014A** CNPV*3017A** CNPV*3117A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CAP**2417A** CAP**3017A** 0.99 CNPH*2417A** CAP**3014A** 0.99 CAP**3617A** 1.00 0.99 CAP**3614A** CAP**2417A** 0.99 CAP**3017A** 0.99 0.99 CAP**3014A** CAP**2414A** 0.99 CAP**2417A** 1.00 0.99 CAP**2414A** CNPV*3717A** 0.98 CSPH*3612A** 0.99 0.98 CSPH*3012A** CNPV*3617A** 1.01 CSPH*2412A** 1.00 0.98 CNPV*3621A** CNPV*3117A** 0.98 CNPV*3617A** 0.99 0.99 CNPV*3117A** CNPV*3017A** 1.01 CNPV*3017A** 0.99 0.98 CNPV*3014A** CNPV*3014A** 0.98 CNPV*2417A** 0.99 0.98 CNPV*2414A** CNPV*2417A** 0.98 CAP**3621A** 0.99 0.98 CAP**3617A** CNPV*2414A** 0.98 CAP**3614A** 0.99 0.98 CAP**3017A** CNPH*3617A** 0.98 CAP**3014A** 0.99 0.98 CAP**2417A** CNPH*3017A** 0.98 High Speed Cap. 1.00 CAP**2414A** *FV4CNF002 Cooling Indoor Model 1.01 1.01 1.00 1.00 1.00 1.00 1.01 1.01 1.02 1.02 1.00 1.01 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.00 1.00 1.00 1.02 1.02 1.02 1.02 1.00 1.00 1.01 1.01 1.02 1.02 1.02 1.02 1.02 1.10 1.10 1.12 1.10 1.10 1.11 1.13 1.11 1.11 1.11 1.11 1.11 1.11 1.11 1.11 1.11 1.11 1.00 Power 1.03 1.03 0.98 0.98 0.98 0.98 0.97 0.97 0.97 0.97 0.98 0.98 0.97 0.97 0.97 0.97 0.96 0.97 0.97 0.98 0.97 0.97 0.96 0.96 0.96 0.96 0.97 0.97 0.97 0.96 0.96 0.96 0.96 0.96 0.96 0.98 0.98 0.98 0.98 0.98 0.97 0.98 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 Low Speed Cap. 1.00 1.04 1.05 1.00 1.00 1.01 1.01 0.99 1.00 1.00 1.00 1.01 1.01 0.99 0.99 1.00 1.00 0.99 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.02 1.00 1.00 0.99 1.00 1.00 1.01 1.19 1.19 1.19 1.19 1.19 1.18 1.19 1.18 1.18 1.18 1.17 1.17 1.17 1.18 1.18 1.18 1.17 1.00 Power 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 Furnace Model CAP**3017A** CAP**2417A** CNPV*3117A** CNPV*3017A** CNPV*3014A** CNPV*2417A** CNPV*2414A** CAP**3621A** CAP**3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CSPH*3612A** CSPH*3012A** CSPH*2412A** CNPH*3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CSPH*3612A** CSPH*3012A** CSPH*2412A** CNPH*3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CSPH*3612A** CSPH*3012A** CSPH*2412A** CAP**3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CAP**3619A** CAP**3619A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPV*3117A** CNPV*3017A** CNPV*2417A** CNPH*3017A** CNPH*2417A** CAP**3621A** CAP**3617A** 0.99 0.99 1.02 1.01 1.01 1.01 1.01 1.02 1.02 1.01 1.01 1.01 1.01 1.01 1.02 1.01 1.00 1.01 1.02 1.02 1.02 1.02 1.01 1.03 1.01 1.00 1.02 1.03 1.03 1.02 1.03 1.02 1.03 1.01 1.00 1.03 1.03 1.03 1.02 1.02 1.02 1.02 1.01 1.01 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.00 High Speed Cap. 1.00 1.01 1.02 1.01 1.02 1.02 1.02 1.02 1.01 1.02 1.02 1.02 1.02 1.02 1.02 1.00 1.01 1.01 1.00 1.00 0.99 1.00 1.00 1.00 1.01 1.01 1.02 1.01 1.01 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.00 1.07 1.00 1.00 1.00 1.01 1.04 1.04 0.99 1.00 1.00 0.99 1.00 1.02 1.00 1.01 0.99 1.00 Power 0.96 0.96 0.97 0.96 0.96 0.97 0.97 0.97 0.96 0.96 0.96 0.96 0.96 0.96 1.06 1.05 1.04 1.05 1.06 1.06 1.06 1.06 1.06 1.03 1.01 0.99 1.02 1.03 1.04 1.02 1.03 1.02 1.04 1.02 1.01 1.05 1.04 1.04 1.04 1.04 1.03 1.02 1.01 1.05 1.04 1.04 1.05 1.03 1.03 1.04 1.04 1.03 Low Speed Cap. 1.03 0.99 0.99 0.99 0.99 0.99 1.00 1.00 0.99 0.99 0.99 0.99 1.00 1.00 1.00 1.06 1.06 1.07 1.06 1.07 1.07 1.07 1.07 1.07 1.02 1.01 1.01 1.01 1.03 1.03 1.02 1.03 1.02 1.02 1.02 1.02 1.04 1.03 1.03 1.03 1.03 1.03 1.04 1.03 1.05 1.06 1.06 1.05 1.05 1.07 1.06 1.08 1.03 1.04 Power 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 359BAV036060 359BAV036040 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 Furnace Model 226ANA024---A Outdoor Section With FV4CNF002 Indoor Section Cooling Indoor Model DETAILED COOLING CAPACITIES# CONTINUED CNPV*2417A** CAP**3621A** CAP**3617A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CSPH*3612A** CSPH*3012A** CSPH*2412A** CAP**3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPV*3117A** CNPV*3017A** CNPV*2417A** CNPH*3617A** CNPH*3017A** CNPH*2417A** CAP**3621A** CAP**3617A** CAP**3017A** CAP**2417A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPV*3117A** CNPV*3017A** CNPV*2417A** CNPH*3617A** CNPH*3017A** CNPH*2417A** CAP**3621A** CAP**3617A** CAP**3017A** CAP**2417A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPV*3117A** CNPV*3017A** CNPV*2417A** CNPH*3617A** CNPH*3017A** CNPH*2417A** CAP**3621A** CAP**3617A** Cooling Indoor Model 226A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 0.99 1.02 1.01 1.01 1.01 1.01 1.00 1.01 1.00 0.99 1.00 0.99 1.00 0.99 0.99 1.00 1.00 1.00 0.99 0.99 0.99 0.98 0.98 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 1.00 0.99 0.99 1.00 0.99 0.99 0.99 0.99 0.99 0.99 High Speed Cap. 0.99 1.02 1.00 1.00 1.00 1.01 1.01 1.01 1.02 1.02 1.02 1.03 1.02 1.02 1.03 1.03 1.02 0.99 0.99 0.98 0.98 0.99 1.01 0.98 0.98 1.00 0.99 1.00 0.99 1.00 0.99 0.99 0.99 1.00 1.00 1.00 0.99 0.99 0.99 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.02 1.00 1.00 1.01 1.00 1.01 Power 1.01 1.01 1.00 1.00 1.00 1.00 1.00 1.01 0.99 0.99 1.02 1.01 1.01 1.01 1.01 1.01 1.05 1.04 1.04 1.05 1.03 1.03 1.04 1.04 1.04 1.03 1.03 1.03 1.03 1.04 1.03 1.03 1.02 1.02 1.02 1.03 1.03 1.03 1.02 1.02 1.02 1.02 0.97 0.97 0.97 0.97 0.96 0.96 0.97 0.97 0.97 0.96 Low Speed Cap. 0.96 1.02 1.00 1.00 1.01 1.01 1.01 1.01 1.03 1.03 1.03 1.04 1.04 1.04 1.04 1.04 1.04 1.04 1.04 1.05 1.05 1.03 1.05 1.05 1.05 1.06 1.03 1.03 1.03 1.04 1.04 1.04 1.04 1.03 1.03 1.05 1.04 1.04 1.06 1.02 1.03 1.03 1.04 0.99 1.00 1.00 1.00 0.99 1.00 1.00 1.00 1.01 0.99 0.99 Power 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 Furnace Model 31 1.00 1.00 1.01 0.98 0.98 0.98 0.98 0.98 0.99 0.98 0.98 0.98 0.98 0.98 0.99 0.98 0.98 0.99 0.98 0.98 0.99 CNPV*3617A** CNPV*3621A** CNPV*3717A** CAP**2414A** CAP**2417A** CAP**3014A** CAP**3017A** CAP**3617A** CAP**3621A** CNPH*2417A** CNPH*3017A** CNPH*3617A** CNPV*2417A** CNPV*3017A** CNPV*3117A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CSPH*2412A** CSPH*3012A** CSPH*3612A** See notes on pg. 40 1.01 High Speed Cap. 1.00 CNPV*3117A** CNPV*3017A** Cooling Indoor Model 1.01 1.01 1.01 0.99 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.01 1.00 0.99 1.00 1.01 1.01 1.01 1.00 1.00 1.01 1.00 1.01 Power 0.97 0.97 0.97 0.98 0.97 0.97 0.98 0.97 0.98 0.97 0.97 0.98 0.97 0.97 0.97 0.97 0.97 0.97 1.01 1.00 1.00 1.01 Low Speed Cap. 1.00 1.00 1.00 1.01 0.99 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.01 0.99 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.00 1.01 Power 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 Furnace Model DETAILED COOLING CAPACITIES# CONTINUED 226ANA024---A Outdoor Section With FV4CNF002 Indoor Section 226A 32 930 840 735 660 CFM 34.25 57 (13.9) 75 (23.9) 34.25 32.00 25.99 27.15 22.04 33.30 30.61 25.00 26.09 21.32 32.79 29.89 24.49 25.54 20.96 31.05 27.59 22.87 23.79 19.79 Sens‡ 25.46 25.30 57 (13.9) 28.12 67 (19.4) 62 (16.7) 31.24 72 (22.2) 25.81 24.43 57 (13.9) 63 (17.2)†† 24.90 62 (16.7) 27.62 67 (19.4) 25.34 30.69 72 (22.2) 63 (17.2)†† 23.27 57 (13.9) 26.89 67 (19.4) 24.19 29.90 72 (22.2) 62 (16.7) 22.31 57 (13.9) 24.67 23.58 62 (16.7) 63 (17.2)†† 24.07 26.25 67 (19.4) 63 (17.2)†† 29.20 72 (22.2) Total 25.30 24.64 19.90 20.90 16.90 24.43 23.36 18.94 19.86 16.19 23.27 21.69 17.76 18.60 15.34 22.31 20.43 16.87 17.64 14.67 Sens‡ Capacity MBtuh† 35.04 38.57 67 (19.4) 62 (16.7) 42.57 72 (22.2) 35.62 33.30 57 (13.9) 63 (17.2)†† 34.47 62 (16.7) 38.01 67 (19.4) 35.09 41.94 72 (22.2) 63 (17.2)†† 32.79 57 (13.9) 37.69 67 (19.4) 34.16 41.59 72 (22.2) 62 (16.7) 31.05 57 (13.9) 34.79 33.07 62 (16.7) 63 (17.2)†† 33.70 36.52 63 (17.2)†† 40.32 Total 67 (19.4) EWB ° F (° C) 75 (23.9) Capacity MBtuh† 72 (22.2) EWB ° F (° C) EVAPORATOR AIR 1200 1100 1050 900 CFM EVAPORATOR AIR 1.55 1.55 1.55 1.54 1.53 1.54 1.54 1.54 1.53 1.52 1.54 1.53 1.53 1.52 1.51 1.54 1.53 1.53 1.52 1.51 Total System KW** 2.20 2.21 2.21 2.23 2.26 2.18 2.19 2.19 2.21 2.24 2.16 2.18 2.18 2.21 2.23 2.13 2.14 2.15 2.17 2.20 Total System KW** 85 (29.4) 32.87 31.14 25.21 26.37 21.29 31.99 29.80 24.23 25.32 20.59 31.50 29.10 23.72 24.78 20.22 29.86 26.84 22.14 23.08 19.08 Sens‡ 24.10 24.14 24.27 26.46 29.44 23.30 23.49 23.86 26.02 28.95 22.22 22.82 23.26 25.38 28.23 21.33 22.27 22.73 24.80 27.61 Total 24.10 24.14 19.23 20.22 16.24 23.30 22.64 18.28 19.20 15.55 22.22 21.04 17.12 17.96 14.71 21.33 19.80 16.25 17.02 14.06 Sens‡ Capacity MBtuh† 32.87 33.35 33.84 36.68 40.52 31.99 32.80 33.37 36.17 39.96 31.50 32.51 33.09 35.87 39.64 29.86 31.50 32.11 34.83 38.48 Total Capacity MBtuh† 85 (29.4) 95 (35) 105 (40.6) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 1.73 1.73 1.73 1.72 1.70 1.73 1.72 1.72 1.71 1.70 1.72 1.72 1.72 1.70 1.69 1.72 1.71 1.71 1.70 1.68 Total System KW** 2.45 2.45 2.46 2.48 2.51 2.43 2.44 2.44 2.46 2.49 2.42 2.42 2.43 2.45 2.48 2.38 2.39 2.40 2.42 2.45 29.92 29.97 30.08 32.67 36.18 29.15 29.33 29.70 32.26 35.73 28.74 29.05 29.49 32.03 35.47 27.30 28.17 28.71 31.19 34.55 29.92 29.97 23.57 24.75 19.75 29.15 28.00 22.62 23.72 19.06 28.74 27.37 22.13 23.20 18.71 27.30 25.25 20.59 21.55 17.60 95 (35) Sens‡ Total System KW** 105 (40.6) Total Sens‡ Capacity MBtuh† 22.86 22.89 22.70 24.76 27.58 22.13 22.17 22.33 24.38 27.16 21.12 21.42 21.81 23.81 26.54 20.30 20.91 21.34 23.31 25.97 22.86 22.89 18.54 19.53 15.58 22.13 22.17 17.61 18.53 14.90 21.12 20.36 16.47 17.30 14.07 20.30 19.16 15.61 16.39 13.45 1.93 1.93 1.93 1.91 1.90 1.93 1.92 1.92 1.91 1.89 1.92 1.92 1.92 1.90 1.88 1.92 1.92 1.91 1.90 1.88 21.57 21.60 21.08 23.04 25.70 20.90 20.93 20.77 22.70 25.33 19.98 20.02 20.30 22.21 24.78 19.22 19.52 19.89 21.76 24.28 21.57 21.60 17.84 18.83 14.91 20.90 20.93 16.92 17.84 14.25 19.98 20.02 15.80 16.64 13.44 19.22 18.49 14.97 15.74 12.83 226ANA036---A Outdoor Section With FV4CNF003 Indoor Section Total 2.72 2.72 2.73 2.75 2.78 2.70 2.70 2.71 2.73 2.76 2.69 2.69 2.70 2.72 2.75 2.65 2.66 2.67 2.69 2.72 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 31.43 30.19 24.41 25.57 20.53 30.61 28.95 23.44 24.53 19.83 30.15 28.27 22.94 24.00 19.48 28.61 26.06 21.38 22.33 18.35 Capacity MBtuh† 31.43 31.62 32.00 34.71 38.39 30.61 31.09 31.57 34.26 37.89 30.15 30.81 31.33 34.00 37.60 28.61 29.87 30.44 33.05 36.55 Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 226ANA036---A---HI Outdoor Section With FV4CNF003 Indoor Section DETAILED COOLING CAPACITIES# CONTINUED 2.15 2.15 2.16 2.14 2.12 2.15 2.15 2.16 2.13 2.11 2.15 2.15 2.15 2.13 2.11 2.15 2.15 2.15 2.13 2.10 Total System KW** 3.03 3.03 3.03 3.05 3.09 3.01 3.01 3.01 3.03 3.07 2.99 3.00 3.00 3.02 3.06 2.96 2.96 2.97 2.99 3.02 Total System KW** 226A 115 (46.1) 115 (46.1) 28.33 28.37 22.71 23.89 18.95 27.62 27.66 21.77 22.88 18.27 27.24 27.28 21.29 22.36 17.92 25.91 24.40 19.78 20.73 16.82 Sens‡ 20.22 20.25 19.43 21.26 23.77 19.61 19.64 19.15 20.97 23.45 18.78 18.81 18.75 20.54 22.97 18.09 18.12 18.39 20.16 22.54 Total 20.22 20.25 17.12 18.11 14.21 19.61 19.64 16.22 17.14 13.59 18.78 18.81 15.12 15.96 12.79 18.09 18.12 14.30 15.07 12.19 Sens‡ Capacity MBtuh† 28.33 28.37 28.08 30.53 33.86 27.62 27.66 27.75 30.18 33.48 27.24 27.28 27.56 29.98 33.25 25.91 26.41 26.87 29.24 32.43 Total Capacity MBtuh† 2.42 2.42 2.43 2.41 2.37 2.42 2.42 2.43 2.40 2.37 2.42 2.42 2.42 2.40 2.36 2.42 2.42 2.42 2.39 2.36 Total System KW** 3.38 3.38 3.37 3.40 3.44 3.35 3.36 3.36 3.38 3.42 3.34 3.34 3.35 3.37 3.41 3.31 3.31 3.32 3.34 3.38 Total System KW** 125 (51.7) 125 (51.7) 26.64 26.67 21.81 23.00 18.10 26.00 26.03 20.89 22.00 17.44 25.64 25.68 20.41 21.49 17.10 24.42 23.45 18.93 19.89 16.02 Sens‡ 18.81 18.84 17.74 19.46 21.79 18.27 18.30 17.49 19.19 21.51 17.51 17.54 17.14 18.83 21.11 16.88 16.91 16.83 18.50 20.75 Total 18.81 18.84 16.36 17.37 13.50 18.27 18.30 15.50 16.43 12.90 17.51 17.54 14.42 15.26 12.14 16.88 16.91 13.62 14.39 11.55 Sens‡ Capacity MBtuh† 26.64 26.67 25.99 28.31 31.46 26.00 26.03 25.70 28.00 31.12 25.64 25.68 25.54 27.83 30.93 24.42 24.58 24.94 27.19 30.22 Total Capacity MBtuh† 2.73 2.73 2.75 2.72 2.68 2.73 2.73 2.75 2.71 2.67 2.74 2.74 2.75 2.71 2.67 2.74 2.74 2.74 2.71 2.67 Total System KW** 3.79 3.79 3.78 3.81 3.85 3.76 3.76 3.76 3.79 3.83 3.75 3.75 3.75 3.78 3.82 3.71 3.71 3.72 3.75 3.79 Total System KW** 33 1.04 1.04 1.05 0.99 0.99 0.99 0.99 1.01 1.01 1.04 1.03 1.03 1.03 0.98 0.99 1.01 0.99 0.99 1.02 1.00 0.99 1.02 1.01 1.01 *FV4CN(B,F)003 FV4CN(B,F)005 FV4CN(B,F)005 FV4CNB006 CAP**3614A** CAP**3617A** CAP**3619A** CAP**3621A** CAP**4221A** CAP**4224A** CAP**4817A** CAP**4821A** CAP**4823A** CAP**4824A** CNPH*3617A** CNPH*4221A** CNPH*4821A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CNPV*4824A** 1.01 1.01 1.01 0.98 0.98 1.02 1.01 0.98 1.02 1.01 1.01 1.02 1.02 0.99 0.99 0.99 1.00 1.02 1.01 1.02 0.99 0.99 1.03 1.01 1.00 1.03 1.02 1.01 CSPH*3612A** CSPH*4212A** CSPH*4812A** CAP**3614A** CAP**3617A** CAP**4817A** CNPH*4821A** CNPV*3617A** CNPV*3717A** CNPV*4217A** CSPH*3612A** CSPH*4212A** CSPH*4812A** CAP**3614A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**4817A** CAP**4821A** CNPH*4821A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CSPH*3612A** Cooling Indoor Model High Speed Cap. 1.00 1.01 1.01 1.01 1.02 1.01 1.01 1.02 1.02 1.01 1.01 1.01 1.01 1.00 1.01 1.01 1.03 1.03 1.03 1.03 1.03 1.03 1.02 1.03 1.02 1.03 1.08 1.08 1.08 1.07 1.07 1.08 1.07 1.08 1.08 1.10 1.10 1.07 1.07 1.07 1.11 1.11 1.11 1.11 1.11 1.11 1.09 1.10 1.09 1.08 0.98 1.00 1.00 1.00 Power 0.97 0.97 0.98 0.96 0.96 0.98 0.95 0.95 0.97 0.97 0.97 0.96 0.95 0.95 0.95 0.97 0.97 0.96 0.96 0.98 0.94 0.96 0.97 0.94 0.94 1.01 1.00 0.99 1.00 1.00 1.01 0.99 0.99 1.01 0.99 0.99 1.00 0.99 0.97 1.02 1.02 1.02 1.04 1.01 1.01 0.99 0.99 0.99 0.98 1.04 1.02 1.02 Low Speed Cap. 1.00 0.99 0.98 0.98 0.99 0.99 0.98 0.99 0.99 0.98 0.99 0.98 0.98 0.98 0.99 0.99 0.99 1.00 1.00 0.99 0.99 1.00 0.99 0.99 0.99 1.00 1.16 1.15 1.15 1.16 1.16 1.15 1.16 1.16 1.15 1.19 1.19 1.16 1.16 1.16 1.19 1.19 1.19 1.20 1.20 1.20 1.19 1.19 1.19 1.16 0.98 0.99 0.99 1.00 Power 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 Furnace Model DETAILED COOLING CAPACITIES# CAP**3614A** CAP**4823A** CAP**4823A** CAP**3619A** CAP**4823A** CAP**3619A** CAP**4823A** CAP**3619A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*3621A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4224A** CAP**4221A** CAP**3621A** CSPH*4212A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*3621A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4224A** CAP**4221A** CAP**3621A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** CAP**3617A** CSPH*4812A** CSPH*4212A** 0.99 1.03 1.04 1.01 1.02 0.99 1.01 0.98 1.02 1.02 1.02 1.02 1.04 1.01 0.99 1.02 1.02 1.02 1.01 1.00 0.99 1.02 1.02 1.02 1.03 1.00 0.99 1.02 1.02 1.01 1.00 1.00 0.99 1.02 1.01 1.02 1.02 1.03 1.00 1.01 1.03 0.99 0.99 1.02 1.02 1.01 1.02 1.00 1.00 0.99 0.99 1.02 High Speed Cap. 1.02 1.02 1.03 1.04 1.04 1.05 1.06 1.07 1.07 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.00 0.99 1.00 1.00 0.99 0.99 1.01 1.00 1.00 1.01 1.01 1.01 1.00 1.01 1.00 1.00 1.00 1.00 1.02 1.01 1.03 1.01 1.01 1.02 1.02 1.01 1.02 1.02 1.01 1.01 1.01 1.02 1.01 1.01 1.01 1.01 1.02 1.01 Power 0.98 1.02 1.04 1.01 1.00 0.98 1.01 0.98 0.98 0.97 0.97 0.97 0.99 0.96 0.95 0.97 0.97 0.97 0.96 0.96 0.95 0.97 0.97 0.97 0.99 0.96 0.95 0.97 0.97 0.97 0.96 0.96 0.95 0.97 0.97 0.97 0.97 0.99 0.96 0.96 0.98 0.95 0.95 0.97 0.97 0.97 0.98 0.96 0.96 0.95 0.95 0.98 Low Speed Cap. 0.97 1.00 1.02 1.04 1.04 1.02 1.03 1.06 1.06 0.99 0.99 0.98 0.98 0.98 0.98 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.99 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.99 0.99 0.98 0.98 0.99 0.99 0.99 0.98 0.99 1.00 0.98 0.98 0.99 0.99 0.98 0.98 0.98 0.99 0.98 0.98 Power 353AAV036040 359BAV060100 359BAV060080 359BAV060080 359BAV036060 359BAV036060 359BAV036040 359BAV036040 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV048090 315(A,J)AV048090 Furnace Model 226ANA036---A Outdoor Section With FV4CNF003 Indoor Section Cooling Indoor Model 226A CAP**3621A** CAP**3617A** CAP**3614A** CSPH*3612A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4821A** CAP**4817A** CAP**4221A** CAP**3621A** CAP**3617A** CAP**3614A** CSPH*3612A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4821A** CAP**4817A** CAP**4221A** CAP**3621A** CAP**3617A** CAP**3614A** CSPH*4212A** CSPH*3612A** CNPV*4821A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4821A** CAP**4817A** CAP**4221A** CAP**3621A** CAP**3617A** Cooling Indoor Model 1.00 1.00 0.99 1.02 1.03 1.04 1.01 1.01 1.04 0.99 0.99 1.03 1.01 0.99 1.02 1.03 1.01 1.00 0.99 0.99 1.02 1.03 1.05 1.01 1.02 1.04 0.99 0.99 1.03 1.01 0.99 1.02 1.03 1.01 1.01 1.00 0.99 1.03 1.02 1.03 1.01 1.02 1.04 0.99 0.99 1.03 1.01 0.99 1.02 1.03 1.01 1.00 High Speed Cap. 0.99 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.01 1.02 1.02 1.01 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.03 1.03 1.02 1.02 1.03 1.02 1.03 1.03 1.02 1.02 1.03 1.02 1.02 1.03 1.01 1.02 1.03 1.01 1.02 1.02 1.02 1.02 1.01 1.01 1.02 1.02 1.02 1.03 1.02 1.03 Power 1.02 1.01 1.01 1.00 1.01 1.02 0.99 0.99 1.01 0.97 0.97 1.01 0.99 0.97 1.00 1.01 0.99 0.99 0.98 0.97 1.01 1.02 1.03 0.99 1.01 1.03 0.99 0.98 1.02 0.99 0.98 1.01 1.02 1.00 0.99 0.99 0.98 1.01 1.01 1.01 0.99 1.00 1.02 0.98 0.98 1.01 0.99 0.98 1.01 1.01 1.00 0.99 Low Speed Cap. 0.99 1.05 1.06 1.06 1.00 0.99 0.99 1.00 1.00 0.99 1.00 1.00 0.99 1.00 1.00 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Power 353AAV048080 353AAV048080 353AAV048080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 Furnace Model 34 1.00 1.00 1.02 1.01 1.01 0.99 0.99 1.03 1.01 1.00 1.03 1.02 1.02 1.01 1.02 1.02 0.99 CAP**4224A** CAP**4817A** CAP**4821A** CAP**4824A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CNPV*4824A** CSPH*3612A** CSPH*4212A** CSPH*4812A** CAP**3617A** 0.99 CNPV*3617A** CAP**4221A** 0.99 CNPH*3617A** 0.99 1.02 CAP**4821A** CAP**3621A** 1.02 CAP**4817A** 0.99 1.01 CAP**4221A** CAP**3617A** 0.99 CAP**3621A** 1.03 0.99 CAP**3617A** CSPH*4812A** 0.99 CAP**3614A** 1.02 1.01 CAP**4221A** CSPH*4212A** 1.00 CAP**3621A** 1.02 0.99 CAP**3617A** CSPH*3612A** 1.02 CSPH*3612A** 1.02 1.04 CNPV*4821A** CNPV*4821A** 1.06 CNPV*4321A** 1.04 1.01 CNPV*4221A** CNPV*4321A** 1.02 CNPV*4217A** 1.01 1.04 CNPV*3717A** CNPV*4221A** 0.99 CNPV*3621A** 1.01 0.99 CNPV*3617A** CNPV*4217A** 1.04 CNPH*4821A** 1.04 1.01 CNPH*4221A** CNPV*3717A** 0.99 CNPH*3617A** 0.99 1.02 CAP**4821A** CNPV*3621A** 1.03 High Speed Cap. 1.01 CAP**4817A** CAP**4221A** Cooling Indoor Model 1.02 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.04 1.04 1.04 1.03 1.03 1.03 1.02 1.03 1.02 1.03 1.02 1.02 1.03 1.02 1.02 1.03 1.03 1.03 1.03 1.04 1.04 1.02 1.02 1.02 1.02 1.03 1.04 0.99 0.99 0.99 1.02 1.04 1.05 1.01 1.02 1.02 1.02 1.02 1.04 1.01 1.02 1.02 1.02 1.02 Power 0.94 0.97 0.97 0.96 0.96 0.96 0.98 0.95 0.96 0.98 0.94 0.94 0.96 0.96 0.97 0.95 0.95 0.95 0.94 0.99 0.99 0.99 0.99 1.00 0.97 0.98 1.00 0.96 0.96 0.96 0.99 0.99 0.97 0.96 0.96 0.96 1.06 1.05 1.04 1.04 1.05 1.06 1.03 1.04 1.06 1.01 1.01 1.05 1.03 1.01 1.04 1.05 Low Speed Cap. 1.03 0.99 0.99 0.99 0.99 0.98 0.98 0.99 0.99 0.99 0.99 0.99 0.99 0.98 0.99 0.99 0.98 0.98 0.99 0.99 0.98 0.99 0.99 0.98 0.98 0.99 0.99 0.99 1.00 1.00 1.00 0.99 0.99 0.98 0.98 0.99 1.00 1.19 1.19 1.19 1.06 1.05 1.05 1.06 1.06 1.05 1.06 1.06 1.05 1.06 1.06 1.05 1.05 1.05 Power 355(A,C)AV060080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 353AAV060100 353AAV060100 353AAV060100 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 Furnace Model CAP**4821A** CAP**4221A** CAP**3621A** CSPH*4812A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*3621A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4224A** CAP**4221A** CAP**3621A** CSPH*4812A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** CAP**3617A** CSPH*4812A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** 1.01 0.99 0.98 1.02 1.02 1.01 1.02 1.02 1.03 1.00 0.99 1.02 1.01 1.01 1.00 1.00 0.99 1.03 1.02 1.02 1.02 1.02 1.04 1.00 1.01 1.03 0.99 0.99 1.02 1.02 1.02 1.02 1.00 1.00 0.99 0.99 1.02 1.02 1.01 1.01 1.01 1.03 0.99 1.01 1.02 0.98 0.98 1.01 1.01 1.02 0.99 0.99 High Speed Cap. 0.99 1.03 1.03 1.02 1.01 1.01 1.01 1.01 1.01 1.01 1.02 1.01 1.01 1.00 1.01 1.01 1.01 1.01 1.03 1.02 1.03 1.02 1.02 1.02 1.02 1.03 1.02 1.03 1.03 1.02 1.02 1.03 1.02 1.02 1.02 1.02 1.03 1.02 1.03 1.03 1.01 1.01 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.01 1.03 1.02 1.02 1.02 Power 0.97 0.96 0.95 0.99 0.98 0.97 0.98 0.98 0.99 0.96 0.96 0.98 0.98 0.97 0.96 0.96 0.96 0.97 0.97 0.96 0.97 0.97 0.98 0.96 0.96 0.98 0.94 0.94 0.97 0.96 0.96 0.97 0.96 0.96 0.95 0.95 0.96 0.96 0.95 0.96 0.96 0.96 0.94 0.95 0.96 0.94 0.94 0.95 0.95 0.96 0.94 0.94 Low Speed Cap. 0.94 0.99 0.99 0.99 0.99 0.99 0.99 0.98 0.98 0.98 0.99 1.00 0.98 0.99 0.98 0.99 0.99 0.99 0.98 0.99 0.99 0.98 0.98 0.98 0.99 0.99 0.98 0.99 0.99 0.98 0.98 0.98 0.98 0.99 0.99 0.99 0.99 0.98 0.99 0.99 0.99 0.99 0.98 0.99 0.99 0.98 0.99 0.99 0.98 0.98 0.98 0.99 0.99 0.99 Power 355AAV042040 355AAV042040 355AAV042040 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 Furnace Model 226ANA036---A Outdoor Section With FV4CNF003 Indoor Section Cooling Indoor Model DETAILED COOLING CAPACITIES# CONTINUED CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** CAP**3617A** CSPH*4212A** CSPH*3612A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4821A** CAP**4817A** CAP**4221A** CAP**3621A** CAP**3617A** CAP**3614A** CSPH*4212A** CSPH*3612A** CNPV*4217A** CNPV*3717A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4817A** CAP**3617A** CAP**3614A** CSPH*4812A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*3621A** CNPH*3617A** CAP**4824A** Cooling Indoor Model 226A 1.02 1.04 0.99 0.99 1.03 1.01 0.99 1.03 1.02 1.03 1.01 1.01 1.00 1.00 1.02 1.01 1.02 1.04 1.00 1.01 1.03 0.99 0.98 1.02 1.00 0.98 1.02 1.02 1.00 0.99 0.99 0.98 1.02 1.01 1.01 1.03 0.98 1.02 0.99 0.98 1.02 0.99 0.98 1.02 1.01 1.01 1.01 1.01 1.02 0.99 0.98 0.98 High Speed Cap. 1.01 1.01 1.02 1.02 1.02 1.01 1.01 1.02 1.01 1.01 1.01 1.01 1.01 1.01 1.02 1.04 1.04 1.04 1.04 1.04 1.04 1.04 1.04 1.03 1.04 1.04 1.03 1.04 1.04 1.03 1.04 1.03 1.04 1.07 1.06 1.07 1.07 1.07 1.07 1.06 1.07 1.07 1.06 1.07 1.03 1.03 1.03 1.03 1.03 1.02 1.04 1.03 1.04 1.02 Power 1.02 1.05 1.00 1.00 1.04 1.01 1.00 1.04 1.04 1.04 1.02 1.02 1.01 1.01 1.04 1.02 1.04 1.04 1.01 1.02 1.04 1.00 1.00 1.04 1.01 1.00 1.03 1.04 1.01 1.01 1.00 1.00 0.99 0.99 0.99 1.01 0.96 1.00 0.98 0.96 1.00 0.97 0.96 0.98 0.97 0.97 0.97 0.97 0.98 0.96 0.95 0.95 Low Speed Cap. 0.97 1.04 1.05 1.05 1.05 1.04 1.05 1.05 1.04 1.05 1.05 1.04 1.05 1.05 1.05 1.07 1.07 1.07 1.06 1.07 1.07 1.07 1.08 1.08 1.07 1.07 1.08 1.07 1.07 1.07 1.07 1.07 1.08 1.01 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 0.99 0.99 1.00 0.99 0.99 0.98 1.00 1.00 1.00 0.99 Power 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 Furnace Model 35 1.04 1.03 1.03 1.02 1.03 1.00 1.01 1.02 0.99 0.99 1.00 1.02 1.02 0.99 0.99 1.04 1.01 1.01 1.04 1.02 0.99 0.99 1.00 1.00 1.02 1.01 1.01 0.99 0.99 1.03 1.01 1.00 1.03 1.02 1.02 0.98 0.98 0.99 1.01 1.01 0.98 0.99 0.98 0.98 1.02 1.00 0.99 1.02 1.01 1.01 1.01 1.02 CNPV*4321A** CNPV*4821A** CNPV*4824A** CSPH*3612A** CSPH*4212A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**4817A** CAP**4821A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**4224A** CAP**4817A** CAP**4821A** CAP**4824A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CNPV*4824A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**4817A** CAP**4821A** CNPH*3617A** CNPH*4221A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CSPH*3612A** CSPH*4212A** CSPH*4812A** CNPV*4221A** Cooling Indoor Model High Speed Cap. 1.01 1.02 1.02 1.02 1.01 1.01 1.02 1.02 1.02 1.02 1.03 1.02 1.03 1.02 1.02 1.01 1.01 1.02 1.00 1.00 1.00 1.01 1.01 1.01 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.02 1.03 1.03 1.03 1.04 1.04 1.04 1.03 1.03 1.02 1.02 1.03 1.01 1.00 1.00 1.01 1.02 1.01 1.01 1.01 1.01 Power 1.01 1.01 1.01 1.01 1.02 0.99 1.00 1.02 0.98 0.98 0.99 0.98 1.01 1.01 0.99 0.99 0.99 1.00 1.00 1.01 0.99 0.99 1.01 0.97 0.97 1.00 1.00 1.01 0.99 0.99 0.98 0.98 1.02 1.04 1.01 1.01 1.04 0.99 0.99 1.02 1.03 1.01 1.00 1.00 1.06 1.05 1.04 1.04 1.03 1.04 1.04 1.05 Low Speed Cap. 1.01 1.01 1.01 1.02 1.01 1.01 1.02 1.02 1.01 1.02 1.03 1.02 1.03 1.01 1.02 1.01 1.01 1.02 0.99 0.99 0.99 1.00 1.00 0.99 1.00 1.00 0.99 0.99 0.99 0.99 0.99 0.99 1.00 1.03 1.03 1.04 1.04 1.03 1.04 1.05 1.03 1.04 1.04 1.04 1.04 1.16 1.16 1.16 1.04 1.05 1.04 1.04 1.04 1.05 Power 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 313*AV060110 313*AV060110 313*AV060110 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 Furnace Model DETAILED COOLING CAPACITIES# 1.02 1.01 1.01 1.01 1.02 0.99 1.01 1.02 0.98 0.98 1.01 0.99 0.98 1.01 1.01 1.02 0.99 0.99 0.99 High Speed Cap. 0.99 See notes on pg. 40 CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** CAP**3617A** Cooling Indoor Model 1.02 1.02 1.01 1.01 1.01 1.02 1.02 1.02 1.01 1.02 1.01 1.02 1.02 1.01 1.02 1.02 1.01 1.01 1.01 1.02 Power 0.99 0.99 0.99 0.99 1.00 0.97 0.98 1.00 0.96 0.96 0.99 0.97 0.96 0.99 0.99 0.99 0.97 0.97 0.96 Low Speed Cap. 0.96 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Power 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 Furnace Model 226ANA036---A Outdoor Section With FV4CNF003 Indoor Section 226A 36 1200 1120 1000 880 CFM 47.01 57 (13.9) 75 (23.9) 47.01 45.31 36.68 38.32 30.99 45.74 43.32 35.29 36.82 29.99 44.98 42.21 34.52 36.00 29.43 42.55 38.88 32.17 33.46 27.76 Sens‡ 34.02 33.62 57 (13.9) 37.71 67 (19.4) 62 (16.7) 41.92 72 (22.2) 34.61 32.81 57 (13.9) 63 (17.2)†† 33.52 62 (16.7) 37.23 67 (19.4) 34.17 41.39 72 (22.2) 63 (17.2)†† 31.45 57 (13.9) 36.39 67 (19.4) 32.70 40.47 72 (22.2) 62 (16.7) 29.89 57 (13.9) 33.38 31.73 62 (16.7) 63 (17.2)†† 32.40 35.33 67 (19.4) 63 (17.2)†† 39.31 72 (22.2) Total 33.62 33.56 27.07 28.40 23.00 32.81 32.29 26.17 27.43 22.34 31.45 30.27 24.76 25.93 21.29 29.89 28.15 23.24 24.29 20.19 Sens‡ Capacity MBtuh† 48.01 52.87 67 (19.4) 62 (16.7) 58.33 72 (22.2) 48.83 45.74 57 (13.9) 63 (17.2)†† 47.25 62 (16.7) 52.12 67 (19.4) 48.13 57.51 72 (22.2) 63 (17.2)†† 44.98 57 (13.9) 51.65 67 (19.4) 46.81 57.01 72 (22.2) 62 (16.7) 42.55 57 (13.9) 47.69 45.31 62 (16.7) 63 (17.2)†† 46.20 50.06 63 (17.2)†† 55.28 Total 67 (19.4) EWB ° F (° C) 75 (23.9) Capacity MBtuh† 72 (22.2) EWB ° F (° C) EVAPORATOR AIR 1600 1470 1400 1200 CFM EVAPORATOR AIR 2.03 2.03 2.03 2.02 2.02 2.02 2.02 2.02 2.01 2.00 2.01 2.01 2.00 2.00 1.99 2.00 1.99 1.99 1.98 1.97 Total System KW** 3.12 3.13 3.13 3.17 3.23 3.08 3.09 3.10 3.14 3.18 3.06 3.07 3.08 3.12 3.16 2.99 3.02 3.02 3.06 3.10 Total System KW** 85 (29.4) 45.31 44.23 35.69 37.32 30.01 44.10 42.31 34.31 35.84 29.04 43.39 41.22 33.55 35.03 28.50 41.09 37.94 31.24 32.54 26.85 Sens‡ 32.33 32.44 32.93 35.90 39.93 31.57 31.95 32.53 35.47 39.46 30.30 31.19 31.82 34.70 38.62 28.82 30.28 30.93 33.74 37.57 Total 32.33 32.31 26.30 27.63 22.25 31.57 31.50 25.41 26.67 21.61 30.30 29.53 24.02 25.18 20.58 28.82 27.44 22.55 23.59 19.50 Sens‡ Capacity MBtuh† 45.31 45.90 46.62 50.50 55.76 44.10 45.19 45.99 49.82 55.01 43.39 44.77 45.60 49.41 54.56 41.09 43.38 44.23 47.95 52.96 Total Capacity MBtuh† 85 (29.4) 95 (35) 105 (40.6) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) Total 3.74 3.74 3.75 3.79 3.84 3.70 3.70 3.71 3.75 3.80 3.68 3.68 3.69 3.73 3.78 3.61 3.63 3.63 3.67 3.72 41.48 41.55 41.76 45.31 50.11 40.44 40.68 41.26 44.77 49.52 39.82 40.29 40.95 44.43 49.15 37.81 39.10 39.85 43.26 47.86 41.48 41.55 33.51 35.17 27.95 40.44 39.97 32.18 33.72 27.00 39.82 38.98 31.44 32.92 26.47 37.81 35.86 29.23 30.55 24.90 95 (35) Sens‡ Total System KW** Total Sens‡ Capacity MBtuh† 105 (40.6) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 43.47 43.31 34.63 36.27 29.02 42.35 41.20 33.27 34.81 28.04 41.68 40.15 32.52 34.00 27.51 39.52 36.93 30.28 31.57 25.90 Capacity MBtuh† 43.47 43.69 44.27 47.98 53.03 42.35 42.99 43.70 47.37 52.35 41.68 42.60 43.34 47.00 51.94 39.52 41.31 42.12 45.68 50.49 2.28 2.28 2.28 2.26 2.25 2.27 2.27 2.27 2.25 2.24 2.26 2.26 2.25 2.24 2.22 2.25 2.24 2.24 2.23 2.21 30.94 30.99 31.14 33.97 37.83 30.23 30.29 30.78 33.59 37.41 29.04 29.56 30.15 32.91 36.65 27.66 28.73 29.34 32.04 35.71 30.94 30.99 25.50 26.82 21.47 30.23 30.29 24.61 25.87 20.84 29.04 28.73 23.25 24.41 19.83 27.66 26.68 21.82 22.85 18.77 2.55 2.55 2.55 2.53 2.51 2.55 2.55 2.54 2.52 2.50 2.54 2.53 2.53 2.51 2.49 2.53 2.52 2.52 2.50 2.47 29.44 29.49 29.23 31.93 35.60 28.78 28.83 28.92 31.59 35.22 27.68 27.85 28.35 30.98 34.55 26.39 27.07 27.64 30.21 33.71 29.44 29.49 24.64 25.97 20.65 28.78 28.83 23.77 25.03 20.03 27.68 27.85 22.42 23.58 19.05 26.39 25.88 21.02 22.07 18.01 226ANA048---A---LO Outdoor Section With FV4CNF005 Indoor Section Total System KW** 3.42 3.42 3.43 3.47 3.52 3.38 3.39 3.39 3.43 3.48 3.35 3.37 3.37 3.41 3.46 3.29 3.31 3.32 3.35 3.40 Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 226ANA048---A---HI Outdoor Section With FV4CNF005 Indoor Section DETAILED COOLING CAPACITIES# CONTINUED 2.86 2.86 2.87 2.84 2.81 2.86 2.86 2.86 2.83 2.80 2.85 2.85 2.84 2.82 2.79 2.85 2.84 2.83 2.81 2.78 Total System KW** 4.10 4.10 4.10 4.14 4.19 4.05 4.06 4.06 4.10 4.16 4.03 4.04 4.04 4.08 4.14 3.96 3.98 3.98 4.02 4.08 Total System KW** 226A 115 (46.1) 115 (46.1) 39.35 39.41 32.33 33.98 26.84 38.38 38.44 31.01 32.55 25.89 37.82 37.89 30.28 31.77 25.37 35.96 34.71 28.11 29.43 23.82 Sens‡ 27.82 27.86 27.20 29.75 33.22 27.21 27.26 26.92 29.45 32.89 26.20 26.25 26.43 28.92 32.30 25.01 25.30 25.80 28.24 31.57 Total 27.82 27.86 23.73 25.06 19.79 27.21 27.26 22.88 24.14 19.18 26.20 26.25 21.55 22.71 18.22 25.01 25.00 20.17 21.23 17.19 Sens‡ Capacity MBtuh† 39.35 39.41 39.08 42.43 47.00 38.38 38.44 38.64 41.96 46.48 37.82 37.89 38.37 41.68 46.16 35.96 36.73 37.41 40.65 45.01 Total Capacity MBtuh† 3.22 3.22 3.23 3.19 3.16 3.21 3.21 3.22 3.19 3.15 3.21 3.21 3.21 3.17 3.14 3.21 3.21 3.20 3.17 3.13 Total System KW** 4.49 4.49 4.49 4.53 4.59 4.45 4.45 4.45 4.49 4.55 4.43 4.43 4.43 4.48 4.53 4.36 4.37 4.37 4.42 4.47 Total System KW** 125 (51.7) 125 (51.7) 37.01 37.06 31.06 32.73 25.66 36.14 36.19 29.76 31.32 24.73 35.62 35.68 29.04 30.54 24.21 33.92 33.42 26.91 28.24 22.69 Sens‡ 26.06 26.10 25.03 27.42 30.67 25.51 25.55 24.79 27.17 30.40 24.58 24.63 24.36 26.71 29.90 23.51 23.55 23.82 26.13 29.26 Total 26.06 26.10 22.76 24.10 18.88 25.51 25.55 21.92 23.19 18.28 24.58 24.63 20.62 21.78 17.34 23.51 23.55 19.27 20.32 16.34 Sens‡ Capacity MBtuh† 37.01 37.06 36.20 39.37 43.68 36.14 36.19 35.82 38.96 43.24 35.62 35.68 35.58 38.71 42.96 33.92 34.19 34.75 37.83 41.98 Total Capacity MBtuh† 3.63 3.63 3.65 3.61 3.57 3.63 3.63 3.64 3.60 3.56 3.63 3.63 3.63 3.59 3.55 3.63 3.63 3.63 3.58 3.54 Total System KW** 4.94 4.94 4.92 4.97 5.03 4.89 4.89 4.89 4.93 4.99 4.87 4.87 4.87 4.91 4.97 4.80 4.80 4.81 4.85 4.91 Total System KW** 37 1.02 0.98 0.97 0.97 0.97 0.99 0.99 0.98 0.99 1.02 0.98 0.98 0.99 1.00 1.00 1.02 0.98 0.97 0.99 0.98 0.99 1.00 0.98 0.99 *FV4CN(B,F)005 FV4CNB006 CAP**4817A** CAP**4821A** CAP**4823A** CAP**4824A** CAP**6021A** CAP**6024A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** CAP**4817A** CAP**4821A** CAP**6021A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CSPH*4812A** 1.00 0.98 0.98 0.98 1.00 1.00 0.98 1.00 1.00 0.98 0.98 1.00 1.01 0.99 1.00 0.98 0.98 1.00 1.00 1.00 1.00 0.98 0.98 1.00 1.01 0.99 1.00 CSPH*6012A** CAP**4817A** CAP**4821A** CAP**4824A** CAP**6021A** CAP**6024A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** CAP**4821A** CAP**4824A** CAP**6021A** CAP**6024A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** Cooling Indoor Model High Speed Cap. 1.00 1.00 1.01 1.00 1.00 0.99 0.99 1.01 1.01 1.00 1.00 0.99 1.00 1.01 1.03 1.00 1.01 1.00 1.00 1.02 1.02 1.01 1.02 1.02 1.01 1.02 1.02 1.02 1.03 1.01 1.02 1.01 1.01 1.01 1.02 1.02 1.09 1.08 1.05 1.05 1.05 1.05 1.09 1.05 1.05 1.05 1.05 1.04 1.04 1.04 1.05 1.00 1.00 Power 0.99 0.97 0.95 0.94 0.93 0.93 1.01 0.94 0.94 0.94 0.93 0.93 0.99 0.97 0.95 0.94 0.93 0.93 1.01 0.94 0.93 0.94 0.94 0.93 0.93 0.93 0.99 0.97 0.93 0.97 0.93 0.93 0.93 0.92 0.93 0.99 0.97 1.00 0.99 0.97 0.97 0.99 0.99 0.97 0.97 0.97 0.96 0.96 0.96 0.97 1.01 Low Speed Cap. 1.00 0.99 1.00 0.95 0.96 0.96 0.96 1.03 0.96 0.96 0.96 0.96 0.97 1.00 1.01 0.95 0.96 0.97 0.97 1.05 0.96 0.97 0.97 0.97 0.97 0.97 0.97 1.00 1.01 0.97 1.00 0.96 0.97 0.97 0.97 0.97 1.13 1.13 1.04 1.04 1.04 1.06 1.14 1.04 1.06 1.13 1.13 1.13 1.13 1.13 1.13 0.99 1.00 Power 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 Furnace Model CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CAP**4817A** CSPH*6012A** CSPH*4812A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6021A** CAP**4821A** CAP**4817A** CAP**6025A** CAP**4823A** CAP**6025A** CAP**4823A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** 1.02 1.01 0.99 0.99 1.01 1.01 0.99 1.01 1.01 0.99 0.98 1.01 0.99 1.02 1.00 0.99 0.99 1.01 1.00 0.99 1.00 1.00 0.98 0.98 0.99 1.01 0.99 0.99 1.01 1.00 0.99 1.00 0.98 0.99 1.00 0.98 1.00 0.98 1.01 0.99 1.01 1.00 1.00 0.99 0.99 1.01 1.00 0.99 1.00 1.00 0.98 High Speed Cap. 0.98 1.01 1.00 1.00 1.00 1.00 1.01 1.00 1.01 1.01 1.01 0.99 1.02 1.01 1.01 1.00 1.01 1.01 1.02 1.01 1.01 1.00 1.01 1.00 1.00 1.01 1.04 1.03 1.04 1.04 1.03 1.04 1.03 1.04 1.04 1.03 1.04 1.05 1.05 1.00 1.01 0.99 1.00 0.98 1.00 1.00 1.01 0.99 1.00 0.99 0.99 0.99 0.99 Power 1.03 1.01 1.00 1.00 1.01 1.01 1.00 1.01 1.01 1.00 1.00 1.04 1.01 1.00 1.03 0.97 1.01 1.03 1.03 1.01 0.99 0.99 0.97 0.97 1.00 1.00 0.99 0.99 1.00 1.00 0.99 0.99 0.97 0.99 0.99 0.97 1.00 0.99 0.99 0.97 0.95 0.94 0.94 0.93 0.93 1.01 0.94 0.93 0.94 0.94 0.93 Low Speed Cap. 0.93 1.02 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.04 1.03 1.04 1.10 1.10 0.99 1.10 0.99 1.10 1.10 1.10 1.10 1.00 1.00 1.00 1.00 1.05 1.02 1.03 1.03 1.03 1.03 1.03 1.02 1.03 1.03 1.02 1.03 1.05 1.05 0.98 0.98 0.95 0.95 0.95 0.96 0.96 1.02 0.95 0.96 0.96 0.96 0.96 0.96 Power 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 359BAV060100 359BAV060100 359BAV060080 359BAV060080 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 Furnace Model 226ANA048---A Outdoor Section With FV4CNF003 Indoor Section Cooling Indoor Model DETAILED COOLING CAPACITIES# CONTINUED 0.99 CNPV*4821A** 226A 1.01 1.00 0.99 1.00 0.98 0.98 1.00 0.99 0.98 1.00 0.99 1.01 1.00 0.98 0.98 1.00 1.00 0.98 1.00 1.00 0.98 0.98 1.00 0.99 1.01 1.00 0.98 0.98 1.00 1.00 0.98 1.00 1.00 0.98 0.98 0.98 0.99 0.98 1.00 0.99 0.97 0.97 0.99 0.99 0.97 0.99 0.99 0.97 0.97 0.98 1.01 High Speed Cap. 0.99 CNPH*6124A** CNPH*6024A** CNPH*4821A** CSPH*6012A** CSPH*4812A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CAP**4817A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CAP**4817A** CSPH*6012A** CSPH*4812A** Cooling Indoor Model 1.02 1.04 1.02 1.02 1.09 1.09 1.08 1.10 1.08 1.08 1.02 1.03 1.01 1.02 1.01 1.01 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.03 1.05 1.04 1.03 1.03 1.03 1.04 1.04 1.04 1.03 1.04 1.03 1.04 1.04 1.02 1.03 1.02 1.01 1.01 1.01 1.03 1.02 1.01 1.02 1.02 1.02 1.03 1.03 1.00 1.00 Power 0.99 1.00 0.99 0.99 0.99 0.97 0.97 0.99 0.99 0.97 0.99 0.97 0.95 0.94 0.93 0.93 1.00 0.94 0.93 0.93 0.93 0.93 0.93 0.99 0.97 0.99 0.97 0.97 0.97 1.00 0.97 0.97 0.97 0.97 0.96 0.96 0.97 0.99 0.97 0.94 0.93 0.93 0.93 0.94 0.93 0.93 0.93 0.93 0.92 0.92 0.93 1.03 Low Speed Cap. 1.01 1.02 1.02 1.00 1.02 1.05 1.05 1.06 1.05 1.05 1.06 1.00 1.00 0.96 0.96 0.96 0.96 1.04 0.96 0.96 0.96 0.96 0.97 0.97 1.01 1.02 1.00 1.00 1.01 1.01 1.06 1.00 1.01 1.01 1.01 1.01 1.02 1.02 1.02 1.02 0.96 0.97 0.98 0.98 0.98 0.97 0.98 0.98 0.98 0.98 0.98 0.98 1.03 1.04 Power 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 353AAV060120 353AAV060120 Furnace Model 38 0.98 0.99 1.00 0.98 0.98 0.99 1.01 0.99 1.00 CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** See notes on pg. 40 0.99 0.98 CAP**4821A** CAP**6024A** 0.98 CAP**4817A** 0.99 1.01 CSPH*6012A** CAP**6021A** 0.99 CSPH*4812A** 0.97 1.02 CNPV*6124A** CAP**4824A** 1.00 CNPV*6024A** 0.97 0.99 CNPV*4824A** CAP**4821A** 0.99 CNPV*4821A** 0.98 1.00 CNPH*6124A** CAP**4817A** 1.00 CNPH*6024A** 1.01 0.99 CNPH*4821A** CNPV*6124A** 1.01 CSPH*6012A** 1.00 0.99 CSPH*4812A** CNPV*6024A** 1.02 CNPV*6124A** 0.98 1.00 CNPV*6024A** CNPV*4824A** 0.99 CNPV*4824A** 0.98 0.99 CNPV*4821A** CNPV*4821A** 1.00 CNPH*6124A** 1.00 1.00 CNPH*6024A** CAP**6024A** 0.99 CNPH*4821A** 1.00 1.01 CSPH*6012A** CAP**6021A** 0.99 CSPH*4812A** 0.98 1.02 CNPV*6124A** CAP**4824A** 1.00 High Speed Cap. 0.99 CNPV*6024A** CNPV*4824A** Cooling Indoor Model 1.02 1.04 1.03 1.01 1.02 1.02 1.03 1.01 1.02 1.02 1.02 1.02 1.03 1.04 1.01 1.02 1.01 1.01 1.02 1.02 1.01 1.02 1.02 1.02 1.02 1.01 1.01 1.01 1.01 1.02 1.02 1.01 1.00 1.01 1.01 0.99 1.00 1.00 1.00 1.00 1.00 1.03 1.02 1.02 1.02 1.02 Power 1.00 0.99 1.01 1.00 0.99 0.99 1.00 1.00 0.99 1.00 1.00 0.99 0.99 0.99 1.01 1.00 0.99 0.99 1.00 1.00 0.99 0.99 0.99 1.03 1.00 1.03 1.01 1.00 1.00 1.01 1.01 1.00 1.04 1.01 1.04 1.03 1.01 1.01 1.03 1.03 1.01 1.00 0.99 1.01 0.99 Low Speed Cap. 0.99 1.03 1.04 1.04 1.04 1.04 1.04 1.04 1.04 1.04 1.05 1.05 1.05 1.06 1.05 1.02 1.03 1.03 1.03 1.04 1.04 1.04 1.05 1.04 1.05 1.05 1.04 1.05 1.05 1.05 1.05 1.05 1.05 1.08 1.08 1.07 1.08 1.08 1.08 1.08 1.08 1.08 1.01 1.02 1.01 1.00 1.02 Power 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 Furnace Model DETAILED COOLING CAPACITIES# CONTINUED 226ANA048---A Outdoor Section With FV4CNF003 Indoor Section 226A 39 56.85 57 (13.9) 1500 1400 1250 1100 CFM 75 (23.9) 56.85 55.15 44.48 46.39 37.06 55.38 52.74 42.77 44.56 35.88 54.55 51.44 41.87 43.59 35.26 51.75 47.40 39.01 40.51 33.31 Sens‡ 40.91 40.84 57 (13.9) 44.98 67 (19.4) 62 (16.7) 49.68 72 (22.2) 41.51 39.93 57 (13.9) 63 (17.2)†† 40.35 62 (16.7) 44.50 67 (19.4) 41.05 49.16 72 (22.2) 63 (17.2)†† 38.41 57 (13.9) 43.62 67 (19.4) 39.44 48.23 72 (22.2) 62 (16.7) 36.63 57 (13.9) 40.22 38.38 62 (16.7) 63 (17.2)†† 39.17 42.52 67 (19.4) 63 (17.2)†† 47.05 72 (22.2) Total 40.84 40.91 32.86 34.41 27.48 39.93 39.40 31.76 33.23 26.71 38.41 36.97 30.05 31.39 25.48 36.63 34.38 28.21 29.41 24.18 Sens‡ Capacity MBtuh† 57.65 63.13 67 (19.4) 62 (16.7) 69.29 72 (22.2) 58.55 55.38 57 (13.9) 63 (17.2)†† 56.80 62 (16.7) 62.35 67 (19.4) 57.80 68.46 72 (22.2) 63 (17.2)†† 54.55 57 (13.9) 61.88 67 (19.4) 56.32 67.96 72 (22.2) 62 (16.7) 51.75 57 (13.9) 57.36 54.68 62 (16.7) 63 (17.2)†† 55.73 60.18 63 (17.2)†† 66.14 Total 67 (19.4) EWB ° F (° C) 75 (23.9) Capacity MBtuh† 72 (22.2) EWB ° F (° C) EVAPORATOR AIR 2000 1835 1750 1500 CFM EVAPORATOR AIR 2.47 2.47 2.47 2.46 2.45 2.46 2.46 2.46 2.44 2.43 2.44 2.44 2.44 2.42 2.41 2.43 2.42 2.41 2.40 2.39 Total System KW** 3.65 3.65 3.66 3.71 3.78 3.59 3.60 3.61 3.66 3.72 3.56 3.57 3.58 3.63 3.70 3.46 3.49 3.50 3.55 3.61 Total System KW** 85 (29.4) 54.68 53.75 43.25 45.15 35.86 53.32 51.47 41.56 43.34 34.69 52.54 50.21 40.67 42.38 34.07 49.93 46.24 37.87 39.33 32.17 Sens‡ 39.25 39.31 39.49 42.78 47.19 38.40 38.47 39.08 42.36 46.73 36.97 37.61 38.33 41.58 45.91 35.30 36.63 37.38 40.58 44.81 Total 39.25 39.31 31.96 33.50 26.58 38.40 38.47 30.87 32.33 25.81 36.97 36.08 29.18 30.52 24.61 35.30 33.54 27.39 28.58 23.32 Sens‡ Capacity MBtuh† 54.68 55.03 55.82 60.15 66.01 53.32 54.23 55.14 59.46 65.26 52.54 53.79 54.75 59.05 64.81 49.93 52.28 53.27 57.42 63.17 Total Capacity MBtuh† 85 (29.4) 95 (35) 105 (40.6) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) Total 4.47 4.47 4.47 4.52 4.59 4.41 4.41 4.42 4.47 4.54 4.38 4.39 4.39 4.44 4.51 4.28 4.30 4.31 4.36 4.43 49.80 49.87 49.72 53.56 58.38 48.66 48.73 49.22 53.05 58.00 48.00 48.23 48.92 52.74 57.76 45.78 46.92 47.79 51.58 56.63 49.80 49.87 40.56 42.44 33.11 48.66 48.73 38.93 40.68 32.03 48.00 47.84 38.06 39.75 31.47 45.78 43.66 35.41 36.88 29.67 95 (35) Sens‡ Total System KW** Total Sens‡ Capacity MBtuh† 105 (40.6) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 52.35 52.42 41.95 43.81 34.59 51.09 50.06 40.29 42.05 33.43 50.38 48.86 39.41 41.10 32.82 47.94 45.00 36.68 38.16 30.96 Capacity MBtuh† 52.35 52.42 52.88 56.90 62.49 51.09 51.51 52.29 56.37 61.85 50.38 51.08 51.94 56.00 61.45 47.94 49.70 50.65 54.67 60.03 2.78 2.78 2.78 2.76 2.74 2.77 2.77 2.76 2.74 2.72 2.75 2.75 2.74 2.72 2.70 2.74 2.73 2.72 2.71 2.68 37.49 37.55 37.30 40.43 44.67 36.71 36.77 36.94 40.04 44.26 35.39 35.63 36.27 39.35 43.51 33.84 34.72 35.43 38.46 42.58 37.49 37.55 30.99 32.53 25.67 36.71 36.77 29.92 31.37 24.91 35.39 35.09 28.25 29.58 23.73 33.84 32.63 26.51 27.69 22.47 3.11 3.11 3.11 3.09 3.06 3.10 3.10 3.10 3.07 3.04 3.09 3.09 3.08 3.05 3.02 3.08 3.07 3.07 3.04 3.01 35.59 35.64 34.95 37.89 41.88 34.87 34.93 34.64 37.56 41.54 33.66 33.72 34.06 36.96 40.88 32.23 32.68 33.32 36.19 40.08 35.59 35.64 29.96 31.50 24.67 34.87 34.93 28.90 30.35 23.93 33.66 33.72 27.26 28.59 22.79 32.23 31.64 25.55 26.75 21.54 226ANA060---A---LO Outdoor Section With FV4CNB006 Indoor Section Total System KW** 4.04 4.04 4.05 4.10 4.17 3.98 3.99 4.00 4.05 4.11 3.95 3.96 3.97 4.02 4.09 3.86 3.88 3.89 3.94 4.00 Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 226ANA060---A Outdoor Section With FV4CNB006 Indoor Section DETAILED COOLING CAPACITIES# CONTINUED 226A 3.49 3.49 3.50 3.46 3.42 3.48 3.48 3.48 3.45 3.41 3.47 3.47 3.47 3.43 3.39 3.47 3.46 3.45 3.42 3.38 Total System KW** 4.94 4.94 4.94 4.99 5.05 4.88 4.88 4.89 4.94 5.00 4.85 4.85 4.86 4.91 4.98 4.75 4.77 4.78 4.83 4.89 Total System KW** 115 (46.1) 115 (46.1) 47.01 47.07 39.08 40.95 31.82 45.98 46.04 37.46 39.21 30.69 45.39 45.46 36.61 38.29 30.10 43.40 42.20 34.01 35.50 28.30 Sens‡ 33.52 33.57 32.46 35.19 38.90 32.88 32.93 32.18 34.91 38.61 31.78 31.83 31.69 34.41 38.08 30.48 30.54 31.05 33.74 37.38 Total 33.52 33.57 28.87 30.40 23.62 32.88 32.93 27.82 29.27 22.88 31.78 31.83 26.21 27.53 21.75 30.48 30.54 24.53 25.73 20.55 Sens‡ Capacity MBtuh† 47.01 47.07 46.35 49.89 54.70 45.98 46.04 45.91 49.46 54.25 45.39 45.46 45.65 49.20 53.96 43.40 43.95 44.71 48.24 52.94 Total Capacity MBtuh† 3.92 3.92 3.94 3.89 3.84 3.91 3.91 3.93 3.88 3.83 3.91 3.91 3.91 3.87 3.82 3.91 3.91 3.90 3.86 3.80 Total System KW** 5.46 5.46 5.45 5.50 5.57 5.40 5.40 5.40 5.45 5.52 5.37 5.37 5.37 5.43 5.50 5.28 5.28 5.29 5.35 5.41 Total System KW** 125 (51.7) 125 (51.7) 43.94 43.98 37.47 39.34 30.27 43.04 43.10 35.90 37.65 29.20 42.52 42.59 35.07 36.74 28.61 40.76 40.83 32.52 33.99 26.84 Sens‡ 31.28 31.32 29.81 32.33 35.72 30.72 30.76 29.58 32.10 35.49 29.74 29.79 29.16 31.67 35.06 28.58 28.63 28.63 31.12 34.49 Total 31.28 31.32 27.70 29.23 22.49 30.72 30.76 26.68 28.13 21.79 29.74 29.79 25.10 26.41 20.67 28.58 28.63 23.45 24.64 19.50 Sens‡ Capacity MBtuh† 43.94 43.98 42.69 45.95 50.29 43.04 43.10 42.35 45.62 50.00 42.52 42.59 42.15 45.40 49.79 40.76 40.83 41.36 44.61 48.93 Total Capacity MBtuh† 4.42 4.42 4.45 4.40 4.34 4.42 4.42 4.44 4.39 4.33 4.42 4.41 4.43 4.38 4.31 4.42 4.42 4.42 4.37 4.30 Total System KW** 6.04 6.05 6.02 6.08 6.14 5.99 5.99 5.97 6.03 6.10 5.95 5.96 5.95 6.00 6.07 5.86 5.86 5.87 5.92 5.99 Total System KW** 40 0.99 0.98 0.98 0.98 0.98 0.99 0.98 1.00 0.99 0.98 0.98 0.98 CNPV*6124A** CSPH*6012A** CAP**6021A** CAP**6024A** CNPH*6024A** CNPH*6124A** CNPV*6024A** CNPV*6124A** CSPH*6012A** CAP**6021A** CAP**6024A** CNPH*6024A** 1.07 1.08 1.01 1.01 1.00 1.02 1.01 1.00 1.01 1.02 1.02 1.01 1.02 1.01 1.01 1.01 1.02 1.02 1.03 1.03 1.03 1.03 1.04 1.05 1.04 1.07 1.05 1.05 1.05 1.05 1.00 Power 0.99 0.99 0.98 0.97 0.96 0.98 0.97 0.96 0.96 0.98 0.98 0.96 0.98 0.97 0.96 0.96 0.98 0.97 0.96 0.98 0.97 0.96 0.96 0.98 1.01 0.97 0.98 0.97 0.97 0.97 Low Speed Cap. 1.00 1.07 1.08 0.98 0.96 0.97 0.99 0.98 0.97 0.98 0.99 0.97 0.97 1.00 0.98 0.98 0.98 1.00 0.98 0.98 1.01 0.99 0.99 0.99 1.13 1.12 1.12 1.13 1.12 1.12 1.12 1.00 Power 359BAV060100 359BAV060080 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 Furnace Model CAP**6021A** 0.98 0.97 CSPH*6012A** 0.96 0.97 0.96 0.97 0.96 0.97 0.98 0.97 0.97 0.97 0.97 0.97 0.99 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.99 0.98 0.98 0.97 0.98 0.97 0.97 0.97 0.96 CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPH*6124A** CNPH*6024A** High Speed Cap. 0.96 1.06 1.05 1.05 1.07 1.05 1.06 1.06 1.07 1.07 1.08 1.08 1.08 1.08 1.09 1.01 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.02 1.01 1.02 1.03 1.03 1.03 Power 0.97 0.96 0.95 0.97 0.95 0.95 0.95 0.98 0.97 0.96 0.97 0.96 0.96 0.96 0.98 0.99 0.98 0.98 0.98 0.97 0.97 0.99 1.00 0.99 0.99 0.99 0.99 0.98 0.96 0.96 0.95 Low Speed Cap. 0.95 1.02 0.99 1.00 1.02 1.00 1.00 1.01 1.03 1.01 1.02 1.03 1.02 1.02 1.02 0.99 0.99 1.00 1.00 1.00 0.99 0.99 1.04 1.05 1.05 1.05 1.05 1.05 1.05 0.99 1.00 0.99 0.99 Power 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV048080 353AAV048080 353AAV048080 353AAV048080 Furnace Model 226ANA060---A Outdoor Section With FV4CNB006 Indoor Section Cooling Indoor Model CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CNPV*6124A** CNPV*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** Cooling Indoor Model 0.98 0.99 0.97 0.98 0.97 0.97 0.97 0.99 0.98 0.98 0.98 0.98 0.99 0.98 0.98 0.98 0.98 0.97 0.99 1.00 0.98 0.99 0.98 0.98 0.98 0.98 0.99 0.97 0.98 0.97 0.97 High Speed Cap. 0.97 1.06 1.06 1.06 1.07 1.06 1.06 1.07 1.03 1.04 1.04 1.04 1.01 1.02 1.01 1.01 1.02 1.02 1.01 1.02 1.02 1.01 1.02 1.01 1.01 1.01 1.04 1.03 1.03 1.05 1.03 1.04 1.04 Power 0.98 0.99 0.98 0.98 0.98 0.98 0.97 0.99 0.98 0.98 0.98 0.98 0.99 0.97 0.97 0.97 0.97 0.97 0.99 1.00 0.99 0.99 0.99 0.99 0.98 0.98 0.97 0.96 0.97 0.97 0.96 Low Speed Cap. 0.96 * Tested combination. { Total and sensible capacities are net capacities. Blower motor heat has been subtracted. } Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C). ** System kw is total of indoor and outdoor unit kilowatts. {{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb. # Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240--- 08. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EWB — Entering Wet Bulb 0.98 0.98 CNPV*6024A** CAP**6025A** 0.98 CNPH*6124A** 0.98 0.98 CNPH*6024A** CAP**6025A** 0.98 CAP**6024A** 0.99 0.98 CAP**6021A** CSPH*6012A** 0.99 CSPH*6012A** 1.00 0.99 CNPV*6124A** CNPV*6124A** 0.99 CNPV*6024A** 0.98 0.99 CNPH*6124A** CNPV*6024A** 0.98 CNPH*6024A** 0.99 0.98 CAP**6024A** CNPH*6124A** 0.98 High Speed Cap. 1.00 CAP**6021A** *FV4CNB006 Cooling Indoor Model DETAILED COOLING CAPACITIES# CONTINUED 226A 1.04 1.04 1.05 1.05 1.05 1.06 1.05 1.02 1.03 1.04 1.04 1.00 1.01 1.00 1.00 1.00 1.01 1.01 1.03 1.03 1.03 1.03 1.03 1.04 1.03 1.01 0.99 0.99 1.01 1.00 1.00 1.00 Power 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 Furnace Model 41 9.98 10.01 10.08 9.62 9.77 9.81 9.88 9.20 9.51 9.55 9.63 735 800 600 700 735 800 600 700 735 800 5.87 5.96 6.06 6.14 5.20 5.31 5.42 5.48 4.46 4.55 4.65 4.73 490 560 625 440 490 560 625 440 490 560 625 Total 440 CFM 7 ( ---13.9) 8.86 8.79 8.75 8.47 9.09 9.03 8.99 8.85 9.28 9.21 9.18 9.06 Integ* 4.35 4.27 4.18 4.10 5.04 4.98 4.88 4.78 5.64 5.57 5.48 5.39 Integ* Capacity MBtuh 9.85 Total 700 See notes on pg. 52 75 (23.9) 70 (21.1) 65 (18.3) EDB ° F (° C) ---3 ( ---19.4) Capacity MBtuh 600 CFM INDOOR AIR 75 (23.9) 70 (21.1) 65 (18.3) EDB ° F (° C) INDOOR AIR 12.07 11.98 11.92 11.75 12.33 12.24 12.19 12.01 12.59 12.50 12.45 12.27 Total 1.11 1.11 1.12 1.13 0.98 0.98 0.99 1.00 0.85 0.85 0.86 0.87 17 ( ---8.3) 1.72 1.73 1.73 1.75 1.64 1.64 1.65 1.67 1.55 1.56 1.56 1.58 Total Sys. KW† 7.34 7.23 7.07 6.95 8.13 8.00 7.85 7.71 9.00 8.91 8.77 8.53 Total 6.69 6.59 6.45 6.33 7.41 7.30 7.16 7.03 8.21 8.12 8.00 7.77 Integ* Capacity MBtuh 11.09 11.01 10.95 10.80 11.33 11.25 11.20 11.04 11.57 11.49 11.44 11.28 Integ* Capacity MBtuh Total System KW† 1.63 1.63 1.63 1.64 1.55 1.55 1.55 1.56 1.46 1.47 1.47 1.48 Total Sys. KW† 7 ( ---13.9) HEAT PUMP HEATING PERFORMANCE 1.21 1.22 1.23 1.25 1.06 1.07 1.09 1.11 0.93 0.95 0.97 0.98 Total System KW† 14.86 14.75 14.68 14.46 15.18 15.06 15.00 14.77 15.49 15.38 15.31 15.08 Total Integ* Total Sys. KW† 37 (2.8) Total Integ* Capacity MBtuh 27 ( ---2.8) 1.82 1.83 1.84 1.87 1.74 1.75 1.75 1.78 1.65 1.66 1.67 1.70 Integ* 16.05 15.93 15.85 15.60 16.38 16.26 16.18 15.93 16.70 16.59 16.51 16.25 1.94 1.96 1.97 2.01 1.86 1.87 1.88 1.92 1.77 1.78 1.79 1.83 21.72 21.57 21.46 21.12 22.13 21.98 21.89 21.54 22.54 22.40 22.31 21.96 19.76 19.63 19.53 19.22 20.14 20.00 19.92 19.60 20.51 20.39 20.30 19.98 10.52 10.39 10.22 10.08 11.12 10.99 10.84 10.71 11.69 11.56 11.40 11.25 9.99 9.34 9.23 9.08 8.95 9.87 9.76 9.62 9.51 10.39 10.27 10.12 2.10 2.11 2.12 2.17 2.01 2.02 2.03 2.08 1.93 1.94 1.95 1.99 Total Sys. KW† Total System KW† Total Integ* Capacity MBtuh 37 (2.8) Total System KW† Total 1.31 1.33 1.36 1.39 1.16 1.18 1.21 1.23 1.01 1.03 1.06 1.09 13.44 13.28 13.09 12.92 14.10 13.94 13.73 13.53 14.78 14.60 14.38 14.17 12.23 12.09 11.91 11.76 12.83 12.69 12.49 12.32 13.45 13.29 13.08 12.90 1.42 1.45 1.49 1.53 1.25 1.28 1.32 1.36 1.11 1.13 1.17 1.21 16.76 16.56 16.30 16.08 17.53 17.31 17.03 16.78 18.31 18.09 17.78 17.51 47 (8.3) 47 (8.3) 25.75 25.62 25.52 25.15 26.22 26.09 26.00 25.64 26.67 26.55 26.46 26.11 Total 226A 16.76 16.56 16.30 16.08 17.53 17.31 17.03 16.78 18.31 18.09 17.78 17.51 Integ* 1.54 1.58 1.63 1.69 1.37 1.41 1.46 1.51 1.22 1.25 1.30 1.35 Total System KW† 25.75 25.62 25.52 25.15 26.22 26.09 26.00 25.64 26.67 26.55 26.46 26.11 Integ* Capacity MBtuh Capacity MBtuh OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C) 18.07 17.93 17.85 17.57 18.44 18.31 18.22 17.93 18.80 18.68 18.59 18.30 226ANA024---A---LO Outdoor Section With FV4CNF002 Indoor Section Total Total Capacity MBtuh 27 ( ---2.8) OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C) 226ANA024---A Outdoor Section With FV4CNF002 Indoor Section Total Sys. KW† Capacity MBtuh 13.55 13.45 13.38 13.18 13.84 13.73 13.67 13.47 14.12 14.02 13.96 13.75 Integ* Capacity MBtuh 17 ( ---8.3) 57 (13.9) 20.57 20.32 19.97 19.68 21.44 21.17 20.81 20.48 22.33 22.06 21.67 21.31 Total 20.57 20.32 19.97 19.68 21.44 21.17 20.81 20.48 22.33 22.06 21.67 21.31 Integ* 2.60 2.61 2.61 2.66 2.51 2.51 2.51 2.56 2.41 2.42 2.42 2.46 Total Sys. KW† 1.71 1.75 1.82 1.89 1.53 1.57 1.63 1.70 1.37 1.41 1.47 1.52 Total System KW† 30.21 30.10 30.02 29.67 30.71 30.60 30.52 30.19 31.20 31.11 31.03 30.71 Integ* 57 (13.9) 30.21 30.10 30.02 29.67 30.71 30.60 30.52 30.19 31.20 31.11 31.03 30.71 Total Capacity MBtuh Capacity MBtuh 2.31 2.32 2.33 2.38 2.23 2.23 2.24 2.29 2.14 2.15 2.15 2.19 Total System KW† 67 (19.4) 67 (19.4) 35.13 35.03 34.96 34.62 35.70 35.60 35.52 35.18 36.30 36.20 36.13 35.79 Integ* 24.86 24.57 24.15 23.78 25.82 25.53 25.07 24.66 26.79 26.50 26.04 25.59 Total 24.86 24.57 24.15 23.78 25.82 25.53 25.07 24.66 26.79 26.50 26.04 25.59 Integ* Capacity MBtuh 35.13 35.03 34.96 34.62 35.70 35.60 35.52 35.18 36.30 36.20 36.13 35.79 Total Capacity MBtuh 1.92 1.97 2.06 2.14 1.73 1.78 1.86 1.94 1.57 1.61 1.68 1.75 Total System KW† 2.97 2.97 2.98 3.01 2.87 2.87 2.87 2.91 2.78 2.78 2.78 2.81 Total Sys. KW† 42 0.99 0.99 0.99 0.99 0.99 0.99 1.02 1.02 1.00 1.00 0.99 0.99 1.03 1.02 1.02 1.03 0.99 CAP**3014A** CAP**3017A** CAP**3614A** CAP**3617A** CAP**3621A** CNPH*2417A** CNPH*3017A** CNPV*2414A** CNPV*2417A** CNPV*3014A** CNPV*3017A** CNPV*3117A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CAP**2417A** 0.99 CAP**3617A** CAP**2417A** 0.99 CAP**3614A** 0.99 0.99 CAP**3017A** CAP**2414A** 0.99 CAP**3014A** 1.03 0.99 CAP**2417A** CNPV*3717A** 0.99 CAP**2414A** 1.02 1.05 CSPH*3612A** CNPV*3617A** 1.04 CSPH*3012A** 1.03 1.06 CSPH*2412A** CNPV*3117A** 1.04 CNPV*3621A** 0.99 1.04 CNPV*3617A** CNPV*3017A** 1.03 CNPV*3117A** 0.99 1.05 CNPV*3017A** CNPV*3014A** 1.02 CNPV*3014A** 1.00 1.02 CNPV*2417A** CNPV*2417A** 1.02 CNPV*2414A** 1.00 1.02 CAP**3621A** CNPV*2414A** 1.02 CAP**3619A** 1.02 1.02 CAP**3617A** CNPH*3617A** 1.02 CAP**3614A** 1.02 1.02 CAP**3017A** CNPH*3017A** 1.02 CAP**3014A** 1.02 1.02 CAP**2417A** CNPH*2417A** 1.02 High Speed Cap. 1.00 CAP**2414A** *FV4CNF002 Heating Indoor Model 1.02 0.99 1.04 1.04 1.01 1.02 1.02 1.01 1.01 1.04 1.03 1.01 1.02 1.02 1.02 1.03 1.02 1.02 1.00 1.05 1.02 1.03 1.03 1.02 1.02 1.05 1.05 1.04 1.02 1.03 1.03 1.04 1.03 1.03 1.11 1.13 1.13 1.13 1.13 1.08 1.14 1.11 1.09 1.09 1.10 1.10 1.10 1.10 1.11 1.11 1.11 1.11 1.00 Power 1.02 1.01 1.00 1.00 1.01 0.98 0.98 0.99 0.99 1.00 1.01 0.98 0.98 0.98 0.98 0.98 0.98 0.98 1.01 1.00 1.01 0.98 0.98 0.98 0.98 1.00 1.00 1.00 0.98 0.98 0.98 0.98 0.98 0.98 1.05 1.04 1.05 1.04 1.04 1.03 1.04 1.02 1.03 1.03 1.03 1.03 1.03 1.03 1.02 1.02 1.02 1.02 Low Speed Cap. 1.00 0.99 1.00 1.04 1.04 1.02 1.02 1.02 1.03 1.03 1.04 1.05 1.02 1.02 1.02 1.03 1.03 1.04 1.04 1.02 1.05 1.03 1.03 1.04 1.04 1.04 1.05 1.05 1.06 1.03 1.03 1.04 1.04 1.04 1.05 1.12 1.13 1.13 1.13 1.13 1.09 1.13 1.11 1.11 1.11 1.11 1.11 1.11 1.11 1.11 1.11 1.12 1.12 1.00 Power 315(A,J)AV060110 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 Furnace Model CAP**2417A** CNPV*3117A** CNPV*3017A** CNPV*3014A** CNPV*2417A** CNPV*2414A** CAP**3621A** CAP**3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CSPH*3612A** CSPH*3012A** CSPH*2412A** CNPH*3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CSPH*3612A** CSPH*3012A** CSPH*2412A** CNPH*3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CSPH*3612A** CSPH*3012A** CSPH*2412A** CAP**3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CAP**3619A** CAP**3619A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPV*3117A** CNPV*3017A** CNPV*2417A** CNPH*3017A** CNPH*2417A** CAP**3621A** CAP**3617A** CAP**3017A** Cooling Indoor Model 0.99 1.01 1.00 1.00 1.01 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.01 1.00 1.02 1.02 1.02 1.02 1.02 1.02 1.01 1.01 1.00 1.03 1.02 1.02 1.03 1.02 1.01 1.00 1.01 1.03 1.02 1.02 1.02 1.02 1.02 1.02 1.01 1.03 1.02 1.02 1.03 0.99 1.01 1.02 1.03 0.99 0.99 High Speed Cap. 0.99 1.03 0.98 1.02 1.03 1.01 1.01 1.01 1.01 1.02 1.02 1.03 1.02 1.02 0.99 1.01 1.01 1.01 1.03 1.04 1.04 1.03 1.04 0.99 1.02 1.01 1.01 1.04 1.03 1.04 1.04 1.04 0.99 1.01 1.01 1.03 1.03 1.03 1.04 1.03 1.04 1.04 1.04 0.99 1.05 1.05 1.01 1.02 1.02 1.05 1.04 1.01 1.02 1.03 Power 0.98 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 1.04 1.03 1.03 1.03 1.05 1.05 1.05 1.05 1.05 1.02 1.01 0.99 1.01 1.03 1.03 1.02 1.02 1.02 1.02 1.01 1.01 1.04 1.03 1.03 1.03 1.03 1.03 1.02 1.01 1.05 1.04 1.04 1.05 1.02 1.03 1.04 1.05 1.02 1.02 Low Speed Cap. 1.02 1.04 1.00 1.03 1.03 1.03 1.03 1.02 1.03 1.03 1.03 1.03 1.04 1.04 0.94 0.97 0.98 0.96 0.98 0.98 0.98 0.99 0.99 0.95 0.98 1.00 0.96 0.98 0.98 0.99 1.00 1.01 0.94 0.97 0.99 0.97 0.98 0.97 0.99 0.99 1.00 0.98 1.00 0.94 0.99 0.99 0.96 0.97 0.99 0.99 1.01 0.96 0.97 0.98 Power 355(A,C)AV042080 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 359BAV036060 359BAV036040 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 Furnace Model 226ANA024---A Outdoor Section With FV4CNF002 Indoor Section HEAT PUMP HEATING PERFORMANCE CONTINUED CAP**3621A** CAP**3617A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CSPH*3612A** CSPH*3012A** CSPH*2412A** CAP**3617A** CAP**3614A** CAP**3017A** CAP**3014A** CAP**2417A** CAP**2414A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPV*3117A** CNPV*3017A** CNPV*2417A** CNPH*3617A** CNPH*3017A** CNPH*2417A** CAP**3621A** CAP**3617A** CAP**3017A** CAP**2417A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPV*3117A** CNPV*3017A** CNPV*2417A** CNPH*3617A** CNPH*3017A** CNPH*2417A** CAP**3621A** CAP**3617A** CAP**3017A** CAP**2417A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPV*3117A** CNPV*3017A** CNPV*2417A** CNPH*3617A** CNPH*3017A** CNPH*2417A** CAP**3621A** CAP**3617A** CAP**3017A** Cooling Indoor Model 226A 1.00 1.00 1.00 1.00 1.00 1.00 1.02 1.00 1.01 1.03 1.02 1.02 1.02 1.02 1.02 1.03 1.02 1.02 1.03 0.99 1.00 1.02 1.02 1.02 0.99 0.99 0.99 0.99 1.03 1.01 1.01 1.02 0.98 1.00 1.01 1.01 1.02 0.98 0.98 0.98 0.98 1.03 1.02 1.02 1.01 0.99 1.00 1.02 1.02 1.02 0.99 0.99 High Speed Cap. 0.99 1.01 1.02 1.02 1.03 1.02 1.02 1.01 1.03 1.03 1.05 1.05 1.05 1.06 1.05 1.06 0.99 1.05 1.05 1.01 1.02 1.01 1.05 1.05 1.03 1.02 1.02 1.03 1.02 1.00 1.05 1.05 1.02 1.03 1.02 1.05 1.05 1.05 1.02 1.02 1.03 1.03 0.99 1.05 1.05 0.99 1.03 1.02 1.05 1.05 1.04 1.02 1.02 1.03 Power 1.00 1.01 1.00 1.00 1.00 1.00 1.01 1.01 1.00 1.03 1.02 1.02 1.02 1.02 1.02 1.05 1.03 1.03 1.05 1.02 1.02 1.03 1.03 1.04 1.02 1.02 1.02 1.02 1.05 1.03 1.03 1.04 1.02 1.02 1.03 1.03 1.03 1.01 1.02 1.01 1.01 1.01 0.99 0.99 0.99 0.98 0.98 0.99 0.99 1.00 0.98 0.98 Low Speed Cap. 0.98 0.98 0.99 0.99 0.99 1.00 1.00 0.98 1.01 1.01 1.01 1.01 1.01 1.02 1.03 1.03 0.95 0.98 0.99 0.96 0.97 0.98 0.99 0.99 1.00 0.96 0.96 0.97 0.98 0.96 1.00 1.00 0.97 0.99 0.99 1.00 1.00 1.01 0.97 0.98 0.98 0.99 1.01 1.05 1.05 1.01 1.03 1.04 1.05 1.05 1.06 1.03 1.03 1.03 Power 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 Furnace Model 43 1.00 1.01 1.00 1.00 1.02 0.99 0.99 0.99 0.99 0.99 0.99 1.00 0.99 0.99 1.00 0.99 1.01 0.99 0.99 1.01 1.00 0.99 1.00 CNPV*2417A** CNPV*3017A** CNPV*3117A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CAP**2414A** CAP**2417A** CAP**3014A** CAP**3017A** CAP**3617A** CAP**3621A** CNPH*2417A** CNPH*3017A** CNPH*3617A** CNPV*2417A** CNPV*3017A** CNPV*3117A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CSPH*2412A** CSPH*3012A** CSPH*3612A** See notes on pg. 52 Heating Indoor Model High Speed Cap. 1.01 1.00 1.03 1.03 0.97 1.03 1.03 0.99 1.03 1.02 1.03 1.03 1.02 1.02 1.02 1.03 1.04 1.03 1.03 0.97 1.02 1.02 0.98 1.02 1.01 Power 0.99 0.99 0.99 1.00 0.99 0.99 1.00 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 1.02 1.00 1.00 1.01 1.00 Low Speed Cap. 1.01 1.01 1.02 1.03 0.98 1.02 1.02 1.00 1.02 1.02 1.02 1.02 1.02 1.01 1.01 1.02 1.02 1.03 1.03 0.95 0.98 0.98 0.96 0.98 0.99 Power 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 Furnace Model 226ANA024---A Outdoor Section With FV4CNF002 Indoor Section HEAT PUMP HEATING PERFORMANCE CONTINUED 226A 44 11.38 11.65 11.72 11.88 10.72 10.97 11.06 11.20 10.00 10.25 10.36 10.48 900 1050 1100 1200 900 1050 1100 1200 900 1050 1100 1200 7.38 7.52 7.69 7.83 6.71 6.86 7.03 7.15 5.98 6.14 6.31 6.44 735 840 930 660 735 840 930 660 735 840 930 Total 5.91 5.79 5.64 5.49 6.57 6.46 6.30 6.17 7.19 7.07 6.92 6.78 Integ* Capacity MBtuh 660 CFM See notes on pg. 52 75 (23.9) 70 (21.1) 65 (18.3) EDB ° F (° C) 7 ( ---13.9) 9.64 9.53 9.43 9.20 10.30 10.17 10.10 9.86 10.93 10.78 10.71 10.47 Capacity MBtuh ---3 ( ---19.4) CFM INDOOR AIR 75 (23.9) 70 (21.1) 65 (18.3) EDB ° F (° C) INDOOR AIR 14.88 14.69 14.59 14.24 15.61 15.43 15.33 14.98 16.30 16.12 16.02 15.68 1.70 1.71 1.71 1.71 1.62 1.63 1.63 1.63 1.55 1.55 1.55 1.56 17 ( ---8.3) 2.21 2.21 2.21 2.22 2.11 2.11 2.12 2.13 2.02 2.02 2.02 2.03 Total Sys. KW† 10.07 9.89 9.64 9.43 10.81 10.64 10.38 10.17 11.52 11.34 11.08 10.86 Total 9.18 9.02 8.79 8.60 9.85 9.70 9.47 9.27 10.50 10.34 10.10 9.90 Integ* Capacity MBtuh 13.67 13.50 13.41 13.09 14.34 14.18 14.08 13.76 14.98 14.81 14.72 14.41 Capacity MBtuh Total System KW† 2.08 2.07 2.07 2.07 1.99 1.98 1.98 1.98 1.90 1.89 1.89 1.89 Total Sys. KW† 7 ( ---13.9) 1.75 1.75 1.76 1.78 1.67 1.67 1.69 1.70 1.59 1.60 1.61 1.62 Total System KW† 19.68 19.44 19.31 18.86 20.46 20.23 20.10 19.64 21.23 20.98 20.84 20.39 Capacity MBtuh 27 ( ---2.8) Total Sys. KW† Capacity MBtuh 37 (2.8) 22.72 22.51 22.39 21.56 23.20 23.03 22.91 22.52 23.69 23.48 23.39 23.00 2.52 2.54 2.55 2.57 2.41 2.43 2.44 2.49 2.30 2.32 2.33 2.38 30.68 30.41 30.25 29.71 31.31 31.04 30.87 30.31 31.94 31.66 31.50 30.93 27.92 27.67 27.53 27.04 28.50 28.24 28.09 27.59 29.07 28.81 28.66 28.14 2.69 2.72 2.73 2.80 2.57 2.60 2.61 2.68 2.46 2.49 2.50 2.57 37 (2.8) OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C) 25.58 25.35 25.21 24.27 26.13 25.93 25.80 25.35 26.67 26.44 26.33 25.90 14.05 13.79 13.45 13.15 14.82 14.56 14.24 13.92 15.54 15.32 14.97 14.67 12.48 12.25 11.95 11.68 13.17 12.93 12.65 12.36 13.80 13.61 13.30 13.03 1.79 1.80 1.82 1.84 1.71 1.72 1.74 1.76 1.63 1.64 1.67 1.69 18.34 18.02 17.60 17.20 19.19 18.86 18.40 18.00 20.01 19.67 19.19 18.77 16.69 16.40 16.01 15.66 17.46 17.16 16.74 16.38 18.21 17.90 17.46 17.09 1.84 1.86 1.89 1.92 1.76 1.78 1.81 1.84 1.68 1.70 1.73 1.76 23.66 22.94 22.23 21.61 24.33 24.00 23.51 22.62 24.94 24.62 24.17 23.74 47 (8.3) 47 (8.3) 36.45 36.08 35.90 35.19 37.16 36.80 36.60 35.89 37.89 37.52 37.31 36.58 23.66 22.94 22.23 21.61 24.33 24.00 23.51 22.62 24.94 24.62 24.17 23.74 1.93 1.93 1.97 2.01 1.84 1.87 1.92 1.93 1.76 1.79 1.83 1.88 Total System KW† 36.45 36.08 35.90 35.19 37.16 36.80 36.60 35.89 37.89 37.52 37.31 36.58 Capacity MBtuh Total Total Capacity MBtuh Capacity MBtuh System System Total Integ* Total Integ* Total Integ* KW† KW† 226ANA036---A---LO Outdoor Section With FV4CNF003 Indoor Section 27 ( ---2.8) 2.34 2.35 2.36 2.38 2.24 2.25 2.26 2.28 2.15 2.15 2.16 2.19 Total Sys. KW† OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C) 226ANA036---A Outdoor Section With FV4CNF003 Indoor Section Total Sys. KW† Capacity MBtuh 17.94 17.73 17.61 17.20 18.66 18.44 18.32 17.91 19.36 19.12 19.00 18.59 Capacity MBtuh 17 ( ---8.3) HEAT PUMP HEATING PERFORMANCE CONTINUED 226A 28.15 27.74 27.20 26.68 28.88 28.45 27.87 27.35 29.60 29.15 28.55 28.03 Total 57 (13.9) 28.15 27.74 27.20 26.68 28.88 28.45 27.87 27.35 29.60 29.15 28.55 28.03 Integ* 3.13 3.17 3.20 3.33 3.00 3.05 3.07 3.19 2.88 2.92 2.95 3.06 Total Sys. KW† 1.99 2.03 2.09 2.15 1.90 1.94 2.00 2.05 1.82 1.86 1.91 1.97 Total System KW† 42.91 42.46 42.21 41.32 43.73 43.28 43.02 42.10 44.56 44.09 43.83 42.90 57 (13.9) 42.91 42.46 42.21 41.32 43.73 43.28 43.02 42.10 44.56 44.09 43.83 42.90 Capacity MBtuh Capacity MBtuh 2.89 2.92 2.95 3.04 2.76 2.80 2.82 2.91 2.65 2.68 2.70 2.79 Total System KW† 67 (19.4) 50.15 49.59 49.28 48.17 51.06 50.49 50.18 49.03 51.97 51.40 51.08 49.91 33.06 32.55 31.76 31.15 33.89 33.34 32.57 31.91 34.72 34.15 33.36 32.66 Total 33.06 32.55 31.76 31.15 33.89 33.34 32.57 31.91 34.72 34.15 33.36 32.66 Integ* Capacity MBtuh 50.15 49.59 49.28 48.17 51.06 50.49 50.18 49.03 51.97 51.40 51.08 49.91 Capacity MBtuh 67 (19.4) 2.07 2.12 2.19 2.26 1.98 2.03 2.10 2.17 1.90 1.94 2.01 2.07 Total System KW† 3.43 3.49 3.53 3.68 3.29 3.35 3.39 3.53 3.16 3.22 3.25 3.39 Total Sys. KW† 45 1.02 1.02 1.02 1.03 1.04 1.04 1.04 1.06 1.06 1.07 1.07 1.07 1.07 1.02 1.03 1.04 1.04 1.04 1.04 1.03 1.03 1.04 1.04 1.04 *FV4CN(B,F)003 FV4CN(B,F)005 FV4CN(B,F)005 FV4CNB006 CAP**3614A** CAP**3617A** CAP**3619A** CAP**3621A** CAP**4221A** CAP**4224A** CAP**4817A** CAP**4821A** CAP**4823A** CAP**4824A** CNPH*3617A** CNPH*4221A** CNPH*4821A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CNPV*4824A** 1.03 1.04 1.04 1.01 1.01 1.03 1.02 1.01 1.02 1.01 1.02 1.02 1.02 1.01 1.01 1.01 1.01 1.02 1.02 1.01 1.00 1.00 1.02 1.01 1.01 1.02 1.01 1.01 CSPH*3612A** CSPH*4212A** CSPH*4812A** CAP**3614A** CAP**3617A** CAP**4817A** CNPH*4821A** CNPV*3617A** CNPV*3717A** CNPV*4217A** CSPH*3612A** CSPH*4212A** CSPH*4812A** CAP**3614A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**4817A** CAP**4821A** CNPH*4821A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CSPH*3612A** Heating Indoor Model High Speed Cap. 1.00 1.00 0.99 0.97 1.01 1.00 0.98 1.03 1.03 0.99 1.00 0.99 1.01 1.02 1.03 1.03 1.00 1.00 1.01 1.01 0.99 1.04 1.00 1.01 1.04 1.05 1.05 1.05 1.06 1.05 1.05 1.03 1.07 1.06 1.03 1.08 1.08 1.05 1.07 1.08 1.06 1.06 1.06 1.04 1.07 1.07 1.08 1.08 1.08 1.08 0.95 0.97 0.97 1.00 Power 0.98 0.98 0.98 0.98 0.98 0.98 0.97 0.97 0.98 0.98 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.97 0.98 0.99 0.98 0.98 1.05 1.04 1.04 1.05 1.05 1.05 1.04 1.04 1.05 1.07 1.07 1.05 1.04 1.03 1.08 1.08 1.08 1.08 1.08 1.08 1.07 1.07 1.07 1.05 1.02 1.02 1.02 Low Speed Cap. 1.00 1.01 1.00 0.99 1.02 1.01 0.99 1.02 1.02 1.00 1.01 1.01 1.02 1.02 1.03 1.03 1.02 1.01 1.02 1.02 1.00 1.03 1.01 1.02 1.04 1.04 1.08 1.08 1.08 1.08 1.08 1.07 1.09 1.08 1.07 1.11 1.11 1.08 1.09 1.10 1.09 1.09 1.09 1.08 1.10 1.10 1.10 1.10 1.10 1.10 0.94 0.96 0.96 0.98 Power 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 315(A,J)AV036070 Furnace Model CAP**4823A** CAP**4823A** CAP**3619A** CAP**4823A** CAP**3619A** CAP**4823A** CAP**3619A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*3621A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4224A** CAP**4221A** CAP**3621A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*3621A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4224A** CAP**4221A** CAP**3621A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** CAP**3617A** CSPH*4812A** CSPH*4212A** Cooling Indoor Model 1.03 1.04 1.02 1.03 1.02 1.03 1.02 1.01 1.01 1.01 1.01 1.02 1.01 1.00 1.01 1.02 1.02 1.01 1.01 1.00 1.01 1.01 1.01 1.01 1.02 1.01 1.00 1.01 1.02 1.02 1.01 1.01 1.00 1.02 1.01 1.01 1.01 1.02 1.01 1.01 1.02 1.00 1.00 1.01 1.02 1.02 1.02 1.01 1.01 1.01 1.01 1.02 High Speed Cap. 1.01 0.99 0.99 1.02 1.01 1.05 1.04 1.07 0.98 0.99 0.97 0.97 0.96 1.00 1.02 0.97 0.98 0.98 1.00 1.00 1.00 0.98 0.99 0.98 0.98 0.96 1.01 1.02 0.98 0.99 0.99 1.00 1.01 1.01 0.99 0.99 0.98 0.98 0.97 1.01 1.00 0.98 1.02 1.02 0.98 0.99 0.99 0.99 1.01 1.01 1.02 1.02 0.99 0.99 Power 1.02 1.03 1.02 1.02 1.00 1.02 1.02 0.98 0.98 0.98 0.98 0.98 0.98 0.97 0.98 0.98 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.97 0.98 0.99 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.97 0.97 0.98 0.99 0.99 0.99 0.98 0.98 0.98 0.98 0.98 Low Speed Cap. 0.98 0.97 0.97 1.00 1.00 1.01 1.01 1.04 1.01 1.01 1.00 1.00 0.99 1.01 1.02 1.00 1.00 1.01 1.02 1.02 1.02 1.01 1.01 1.00 1.00 0.99 1.01 1.02 1.00 1.01 1.02 1.02 1.02 1.02 1.01 1.01 1.00 1.00 0.99 1.01 1.01 0.99 1.02 1.02 1.00 1.02 1.02 1.01 1.02 1.02 1.03 1.03 1.00 1.01 Power 359BAV060100 359BAV060080 359BAV060080 359BAV036060 359BAV036060 359BAV036040 359BAV036040 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV048090 315(A,J)AV048090 Furnace Model 226ANA036---A Outdoor Section With FV4CNF003 Indoor Section HEAT PUMP HEATING PERFROMANCE CONTINUED 226A CAP**3617A** CAP**3614A** CSPH*3612A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4821A** CAP**4817A** CAP**4221A** CAP**3621A** CAP**3617A** CAP**3614A** CSPH*3612A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4821A** CAP**4817A** CAP**4221A** CAP**3621A** CAP**3617A** CAP**3614A** CSPH*4212A** CSPH*3612A** CNPV*4821A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4821A** CAP**4817A** CAP**4221A** CAP**3621A** CAP**3617A** CAP**3614A** Cooling Indoor Model 1.01 1.01 1.02 1.02 1.03 1.01 1.02 1.03 1.01 1.01 1.02 1.01 1.01 1.02 1.02 1.01 1.01 1.01 1.01 1.02 1.03 1.03 1.02 1.02 1.03 1.01 1.01 1.03 1.02 1.01 1.02 1.03 1.02 1.01 1.01 1.01 1.02 1.02 1.02 1.01 1.02 1.03 1.01 1.01 1.02 1.01 1.01 1.02 1.03 1.01 1.01 1.01 High Speed Cap. 1.01 1.02 1.02 0.99 0.98 0.97 1.01 1.00 0.97 1.02 1.03 0.98 1.01 1.03 0.99 0.98 1.00 1.01 1.02 1.03 0.99 0.98 0.97 1.01 1.00 0.97 1.02 1.02 0.98 1.01 1.02 0.98 0.98 1.00 1.01 1.02 1.02 0.98 0.99 0.98 1.00 1.00 0.97 1.02 1.02 0.98 1.00 1.02 0.98 0.98 1.00 1.01 1.01 1.02 Power 1.03 1.03 1.00 1.01 1.02 1.00 1.00 1.02 0.99 0.99 1.01 1.00 0.99 1.01 1.01 1.00 1.00 0.99 0.99 1.01 1.02 1.02 1.01 1.01 1.02 1.00 1.00 1.02 1.01 1.00 1.01 1.02 1.01 1.01 1.00 1.00 1.01 1.01 1.02 1.00 1.01 1.02 1.00 0.99 1.02 1.00 1.00 1.01 1.02 1.01 1.00 1.00 Low Speed Cap. 0.99 0.99 1.00 0.99 0.97 0.97 1.00 0.98 0.97 1.00 1.00 0.97 0.99 1.00 0.98 0.98 0.99 0.99 1.00 1.01 0.98 0.97 0.96 0.99 0.98 0.96 1.00 1.00 0.97 0.99 1.00 0.97 0.97 0.98 0.99 0.99 1.00 0.98 0.99 0.97 0.99 0.98 0.97 1.00 1.00 0.97 0.98 1.00 0.97 0.97 0.98 0.99 1.00 1.00 Power 353AAV048080 353AAV048080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036080 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036060 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 353AAV036040 Furnace Model 46 1.01 1.02 1.02 1.03 1.02 1.02 1.01 1.01 1.01 1.03 1.02 1.01 1.03 1.02 1.02 1.02 1.02 CAP**4221A** CAP**4224A** CAP**4817A** CAP**4821A** CAP**4824A** CNPV*3617A** CNPV*3621A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CNPV*4824A** CSPH*3612A** CSPH*4212A** 1.01 CNPH*3617A** CAP**3621A** 1.03 CAP**4821A** 1.01 1.03 CAP**4817A** CAP**3617A** 1.02 CAP**4221A** 1.02 1.01 CAP**3621A** CSPH*4812A** 1.01 CAP**3617A** 1.02 1.02 CAP**3614A** CSPH*4212A** 1.01 CAP**4221A** 1.02 1.00 CAP**3621A** CSPH*3612A** 1.00 CAP**3617A** 1.02 1.02 CSPH*3612A** CNPV*4821A** 1.04 CNPV*4821A** 1.03 1.05 CNPV*4321A** CNPV*4321A** 1.02 CNPV*4221A** 1.01 1.02 CNPV*4217A** CNPV*4221A** 1.03 CNPV*3717A** 1.02 1.01 CNPV*3621A** CNPV*4217A** 1.01 CNPV*3617A** 1.03 1.04 CNPH*4821A** CNPV*3717A** 1.02 CNPH*4221A** 1.01 1.01 CNPH*3617A** CNPV*3621A** 1.02 CAP**4821A** 1.01 1.03 CAP**4817A** CNPV*3617A** 1.02 High Speed Cap. 1.01 CAP**4221A** CAP**3621A** Heating Indoor Model 1.00 1.01 1.00 1.00 0.99 1.02 1.01 0.99 1.04 1.04 1.04 1.00 1.01 1.00 1.03 1.03 1.03 1.04 0.98 0.99 1.00 0.98 0.97 1.01 1.00 0.98 1.03 1.03 1.03 1.00 0.99 1.01 1.02 1.03 1.04 1.00 1.00 1.01 1.00 0.98 0.97 1.01 1.00 0.97 1.02 1.02 0.98 1.01 1.02 0.98 0.98 1.01 1.01 Power 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.97 0.97 0.97 0.98 0.98 0.99 0.98 0.98 0.98 0.98 0.99 0.99 0.99 0.99 1.00 0.99 0.99 1.00 0.98 0.98 0.98 1.00 1.01 0.99 0.99 0.99 0.99 1.09 1.09 1.09 1.04 1.05 1.05 1.04 1.04 1.05 1.03 1.03 1.05 1.04 1.03 1.04 1.05 1.04 Low Speed Cap. 1.03 1.01 1.02 1.00 1.00 1.00 1.02 1.01 1.00 1.03 1.03 1.03 1.02 1.02 1.02 1.02 1.02 1.03 1.04 0.98 0.99 1.00 0.98 0.98 1.01 1.00 0.98 1.01 1.01 1.01 1.00 1.00 1.00 1.01 1.02 1.02 1.04 1.04 1.05 0.98 0.97 0.96 0.99 0.98 0.96 1.00 1.00 0.97 0.99 1.00 0.97 0.97 0.99 0.99 Power 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042080 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 355(A,C)AV042060 353AAV060100 353AAV060100 353AAV060100 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 Furnace Model CAP**3621A** CSPH*4812A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*3621A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4224A** CAP**4221A** CAP**3621A** CSPH*4812A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** CAP**3617A** CSPH*4812A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** CAP**3617A** CSPH*4812A** Cooling Indoor Model 1.01 1.02 1.01 1.01 1.01 1.01 1.02 1.01 1.00 1.01 1.02 1.02 1.01 1.01 1.01 1.02 1.02 1.02 1.02 1.02 1.03 1.01 1.02 1.03 1.01 1.01 1.02 1.02 1.02 1.03 1.01 1.01 1.01 1.01 1.02 1.02 1.01 1.02 1.02 1.02 1.01 1.01 1.02 1.00 1.01 1.02 1.02 1.03 1.01 1.01 1.01 1.01 High Speed Cap. 1.02 1.04 0.98 0.99 1.00 0.98 0.98 0.97 1.01 1.03 0.98 0.99 0.99 1.01 1.01 1.02 0.99 0.99 1.00 0.99 0.99 0.98 1.01 1.00 0.98 1.03 1.03 0.99 0.99 1.00 0.99 1.01 1.01 1.02 1.03 0.99 1.00 1.00 1.00 1.00 0.98 1.02 1.01 0.98 1.03 1.04 1.00 1.01 1.00 1.02 1.02 1.03 1.03 1.00 Power 0.98 0.98 0.98 0.98 0.98 0.98 0.99 0.98 0.98 0.98 0.99 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.97 0.97 0.98 0.98 0.98 0.99 0.98 0.98 0.98 0.98 0.97 0.97 0.97 0.97 0.97 0.98 0.95 0.97 0.98 0.94 0.94 0.98 0.96 0.98 0.96 0.96 0.95 0.95 Low Speed Cap. 0.98 1.03 0.99 1.00 1.01 0.99 0.99 0.99 1.01 1.02 0.99 1.01 1.01 1.01 1.01 1.02 1.01 1.01 1.01 1.00 1.00 0.99 1.02 1.01 1.00 1.02 1.02 1.00 1.01 1.01 1.01 1.03 1.03 1.03 1.03 1.02 1.02 1.03 1.01 1.01 1.01 1.02 1.02 1.01 1.03 1.03 1.03 1.02 1.03 1.03 1.03 1.03 1.03 1.00 Power 355AAV042040 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV042080 Furnace Model 226ANA036---A Outdoor Section With FV4CNF003 Indoor Section HEAT PUMP HEATING PERFROMANCE CONTINUED CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** CAP**3617A** CSPH*4212A** CSPH*3612A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4821A** CAP**4817A** CAP**4221A** CAP**3621A** CAP**3617A** CAP**3614A** CSPH*4212A** CSPH*3612A** CNPV*4217A** CNPV*3717A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4817A** CAP**3617A** CAP**3614A** CSPH*4812A** CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*3621A** CNPH*3617A** CAP**4824A** CAP**4821A** CAP**4221A** Cooling Indoor Model 226A 1.01 1.00 1.02 1.01 1.00 1.02 1.02 1.02 1.01 1.01 1.01 1.01 1.03 1.02 1.03 1.03 1.02 1.02 1.03 1.01 1.01 1.03 1.02 1.01 1.03 1.03 1.02 1.01 1.01 1.01 1.03 1.03 1.03 1.04 1.02 1.04 1.03 1.02 1.04 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.01 1.01 1.01 1.02 1.02 High Speed Cap. 1.01 1.02 1.02 0.98 1.00 1.02 0.98 0.98 0.97 0.99 1.00 1.00 1.01 1.01 1.02 1.00 0.99 1.03 1.02 1.00 1.05 1.05 1.00 1.03 1.05 1.01 1.00 1.03 1.03 1.04 1.05 1.03 1.04 1.04 1.01 1.07 1.03 1.05 1.07 1.02 1.06 1.07 1.00 1.01 1.02 1.00 1.00 0.99 1.03 1.05 1.05 1.01 1.02 1.03 Power 1.02 1.02 1.04 1.03 1.02 1.04 1.04 1.04 1.03 1.03 1.03 1.02 1.04 1.04 1.04 1.05 1.03 1.04 1.05 1.02 1.02 1.04 1.03 1.02 1.04 1.04 1.03 1.03 1.03 1.02 1.00 1.00 1.00 1.01 0.99 1.01 1.00 0.99 1.01 0.99 0.99 0.98 0.98 0.98 0.98 0.98 0.99 0.98 0.97 0.97 0.99 0.99 Low Speed Cap. 0.98 1.01 1.01 0.97 1.00 1.01 0.98 0.98 0.98 0.99 0.99 1.00 1.00 1.00 1.01 0.99 0.99 1.01 1.01 0.99 1.02 1.02 0.99 1.01 1.02 1.00 0.99 1.01 1.01 1.02 1.02 1.00 1.01 1.01 0.99 1.02 1.00 1.02 1.02 1.00 1.02 1.03 1.01 1.01 1.02 1.00 1.00 1.00 1.02 1.02 1.02 1.02 1.02 1.03 Power 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 313*AV024045 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 355AAV042040 Furnace Model 47 1.02 1.01 1.03 1.02 1.02 1.02 1.02 1.01 1.01 1.01 1.01 1.01 1.01 1.03 1.02 1.01 1.01 1.03 1.02 1.02 1.03 1.02 1.00 0.99 1.00 1.00 1.02 1.01 1.01 1.00 1.00 1.02 1.01 1.01 1.02 1.01 1.01 1.00 1.00 1.00 1.02 1.01 1.00 1.01 1.00 1.00 1.02 1.01 1.01 1.02 1.01 1.01 CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CNPV*4824A** CSPH*3612A** CSPH*4212A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**4817A** CAP**4821A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**4224A** CAP**4817A** CAP**4821A** CAP**4824A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CNPV*4824A** CAP**3617A** CAP**3621A** CAP**4221A** CAP**4817A** CAP**4821A** CNPH*3617A** CNPH*4221A** CNPV*3617A** CNPV*3621A** CNPV*3717A** CNPV*4217A** CNPV*4221A** CNPV*4321A** CNPV*4821A** CSPH*3612A** CNPV*3717A** Cooling Indoor Model High Speed Cap. 1.03 1.02 1.00 0.99 1.03 1.02 0.99 1.05 1.05 1.03 1.05 1.01 1.00 1.02 1.03 1.04 0.98 0.98 0.97 1.01 0.99 0.97 1.02 1.02 0.98 0.99 0.98 1.00 1.00 1.01 1.02 0.99 0.98 1.02 1.01 0.99 1.04 1.04 1.00 0.99 1.01 1.03 1.03 0.99 1.00 1.00 0.98 0.99 0.98 0.98 0.96 1.00 0.99 0.97 Power 1.01 1.01 1.02 1.01 1.01 1.02 1.00 1.00 1.01 1.00 1.01 1.02 1.01 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.01 0.99 0.99 1.00 1.00 1.01 0.99 0.99 0.99 0.99 1.02 1.03 1.02 1.02 1.03 1.02 1.02 1.02 1.03 1.02 1.02 1.02 1.09 1.08 1.08 1.04 1.03 1.04 1.04 1.05 1.03 1.03 Low Speed Cap. 1.04 0.99 0.98 0.97 1.00 0.99 0.98 1.01 1.01 1.00 1.01 0.98 0.98 1.00 1.00 1.00 0.97 0.97 0.97 1.00 0.99 0.97 1.00 1.00 0.98 0.98 0.98 0.99 0.99 1.00 1.00 0.98 0.97 1.00 0.99 0.97 1.01 1.01 0.98 0.98 1.00 1.00 1.00 1.02 1.02 1.03 0.98 0.98 0.97 0.97 0.97 1.00 0.99 0.97 Power 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 374RAN036105 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 368RAN036105 313*AV060110 313*AV060110 313*AV060110 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 Furnace Model 1.01 1.01 1.01 1.01 1.02 1.01 1.01 1.02 1.00 1.00 1.01 1.01 1.00 1.01 1.01 1.02 1.00 1.00 1.00 1.00 1.02 High Speed Cap. 1.01 See notes on pg. 52 CSPH*4212A** CSPH*3612A** CNPV*4824A** CNPV*4821A** CNPV*4321A** CNPV*4221A** CNPV*4217A** CNPV*3717A** CNPV*3621A** CNPV*3617A** CNPH*4821A** CNPH*4221A** CNPH*3617A** CAP**4824A** CAP**4821A** CAP**4817A** CAP**4224A** CAP**4221A** CAP**3621A** CAP**3617A** CSPH*4812A** CSPH*4212A** Cooling Indoor Model 0.99 1.00 0.99 0.99 0.98 1.02 1.01 0.98 1.03 1.03 0.99 1.02 1.03 0.99 1.00 0.99 1.01 1.01 1.02 1.03 1.00 1.01 Power 0.99 0.99 0.99 0.99 1.00 0.99 0.99 1.00 0.98 0.98 0.99 0.99 0.98 0.99 0.99 1.00 0.98 0.98 0.98 0.98 1.02 Low Speed Cap. 1.02 1.00 1.00 0.99 0.99 0.99 1.01 1.00 0.99 1.02 1.02 0.99 1.01 1.02 1.00 1.00 1.00 1.00 1.00 1.01 1.01 0.99 0.99 Power 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN036105 374RAN036105 Furnace Model 226ANA036---A Outdoor Section With FV4CNF003 Indoor Section HEAT PUMP HEATING PERFROMANCE CONTINUED 226A 48 16.58 16.93 17.04 17.22 15.85 16.22 16.35 16.54 15.08 15.45 15.57 15.77 1200 1400 1470 1600 1200 1400 1470 1600 1200 1400 1470 1600 10.75 11.70 11.94 12.14 12.25 11.03 11.27 11.46 11.58 10.31 10.55 10.75 10.87 880 1000 1120 1200 880 1000 1120 1200 880 1000 1120 1200 9.99 9.88 9.70 9.47 10.64 10.53 10.36 10.14 11.26 11.15 10.97 Integ* Capacity MBtuh Total CFM See notes on pg. 52 75 (23.9) 70 (21.1) 65 (18.3) EDB ° F (° C) 21.26 21.03 20.89 20.43 21.99 21.78 21.65 21.21 22.70 22.48 22.35 21.92 2.36 2.36 2.37 2.38 2.24 2.24 2.25 2.26 2.12 2.12 2.12 2.14 3.11 3.10 3.10 3.10 2.98 2.97 2.97 2.98 2.86 2.85 2.85 2.85 15.58 15.43 15.15 14.82 16.30 16.15 15.89 15.57 16.99 16.84 16.56 16.24 Total 14.21 14.07 13.81 13.52 14.86 14.73 14.49 14.19 15.49 15.35 15.10 14.81 Integ* Capacity MBtuh 19.54 19.32 19.20 18.77 20.21 20.02 19.89 19.49 20.86 20.66 20.54 20.14 Total Sys. KW† 17 ( ---8.3) 7 ( ---13.9) Capacity MBtuh Total System KW† 2.95 2.93 2.93 2.91 2.83 2.82 2.81 2.80 2.71 2.70 2.69 2.68 Total Sys. KW† 7 ( ---13.9) 14.50 14.32 14.22 13.88 15.22 15.04 14.92 14.59 15.85 15.67 15.57 15.25 Capacity MBtuh ---3 ( ---19.4) CFM INDOOR AIR 75 (23.9) 70 (21.1) 65 (18.3) EDB ° F (° C) INDOOR AIR 2.43 2.43 2.45 2.47 2.30 2.31 2.32 2.35 2.18 2.18 2.20 2.23 Total System KW† 27.37 27.06 26.88 26.30 28.82 28.59 27.97 27.18 29.32 29.11 28.99 28.56 Capacity MBtuh 27 ( ---2.8) Total Sys. KW† Capacity MBtuh 37 (2.8) 30.29 30.06 29.90 29.47 30.80 30.57 30.43 29.98 31.28 31.05 30.91 30.47 3.48 3.49 3.50 3.54 3.34 3.35 3.36 3.40 3.20 3.21 3.22 3.26 40.56 40.22 40.02 39.37 41.26 40.92 40.72 40.05 41.94 41.61 41.41 40.74 36.91 36.60 36.42 35.82 37.55 37.24 37.06 36.45 38.16 37.87 37.69 37.08 3.67 3.69 3.70 3.77 3.53 3.55 3.56 3.62 3.39 3.41 3.42 3.48 37 (2.8) OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C) 34.11 33.84 33.67 33.18 34.68 34.42 34.26 33.75 35.22 34.96 34.81 34.31 20.74 20.52 20.20 19.79 21.47 21.28 20.95 20.53 22.17 21.98 21.61 21.24 18.42 18.23 17.94 17.57 19.07 18.90 18.60 18.24 19.69 19.52 19.20 18.87 2.49 2.51 2.53 2.57 2.36 2.38 2.40 2.45 2.24 2.25 2.28 2.32 26.56 26.24 25.76 25.19 27.85 27.42 26.75 26.03 28.37 28.19 27.86 27.12 24.17 23.88 23.44 22.92 25.34 24.95 24.35 23.68 25.81 25.65 25.36 24.68 2.57 2.59 2.63 2.69 2.48 2.48 2.51 2.56 2.35 2.37 2.42 2.45 32.76 32.51 32.10 31.63 33.34 33.10 32.71 32.19 33.93 33.68 33.27 32.78 47 (8.3) 47 (8.3) 47.85 47.43 47.18 46.32 48.67 48.25 48.00 47.15 49.49 49.07 48.82 47.96 32.76 32.51 32.10 31.63 33.34 33.10 32.71 32.19 33.93 33.68 33.27 32.78 2.70 2.73 2.80 2.89 2.56 2.59 2.66 2.74 2.43 2.46 2.52 2.60 Total System KW† 47.85 47.43 47.18 46.32 48.67 48.25 48.00 47.15 49.49 49.07 48.82 47.96 Capacity MBtuh Total Total Capacity MBtuh Capacity MBtuh System System Total Integ* Total Integ* Total Integ* KW† KW† 226ANA048---A---LO Outdoor Section With FV4CNF005 Indoor Section 27 ( ---2.8) 3.27 3.27 3.27 3.29 3.16 3.16 3.15 3.16 3.04 3.04 3.04 3.06 Total Sys. KW† OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C) 226ANA048---A Outdoor Section With FV4CNF005 Indoor Section Total Sys. KW† Capacity MBtuh 24.95 24.67 24.51 23.98 26.28 26.07 25.51 24.78 26.73 26.55 26.43 26.04 Capacity MBtuh 17 ( ---8.3) HEAT PUMP HEATING PERFORMANCE CONTINUED 226A 38.73 38.41 37.86 37.21 39.45 39.14 38.58 37.89 40.17 39.85 39.29 38.59 Total 56.04 55.53 55.23 54.15 57.01 56.48 56.18 55.09 58.01 57.48 57.15 56.03 57 (13.9) 56.04 55.53 55.23 54.15 57.01 56.48 56.18 55.09 58.01 57.48 57.15 56.03 Capacity MBtuh 38.73 38.41 37.86 37.21 39.45 39.14 38.58 37.89 40.17 39.85 39.29 38.59 Integ* 4.18 4.22 4.25 4.36 4.04 4.07 4.10 4.20 3.89 3.93 3.95 4.05 Total Sys. KW† 2.80 2.84 2.92 3.04 2.67 2.71 2.78 2.88 2.54 2.57 2.64 2.74 Total System KW† 57 (13.9) Capacity MBtuh 3.90 3.93 3.95 4.04 3.76 3.78 3.80 3.89 3.62 3.64 3.66 3.74 Total System KW† 67 (19.4) 65.66 64.96 64.53 63.03 66.90 66.20 65.77 64.24 68.14 67.43 67.00 65.46 45.43 45.03 44.32 43.42 46.29 45.88 45.15 44.24 47.15 46.73 45.99 45.05 Total 45.43 45.03 44.32 43.42 46.29 45.88 45.15 44.24 47.15 46.73 45.99 45.05 Integ* Capacity MBtuh 65.66 64.96 64.53 63.03 66.90 66.20 65.77 64.24 68.14 67.43 67.00 65.46 Capacity MBtuh 67 (19.4) 2.94 2.99 3.09 3.22 2.80 2.85 2.94 3.07 2.67 2.72 2.80 2.92 Total System KW† 4.56 4.60 4.64 4.77 4.40 4.45 4.48 4.61 4.26 4.30 4.33 4.45 Total Sys. KW† 49 High Speed Cap. 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.04 1.01 1.01 1.01 1.02 1.03 1.04 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 1.00 0.99 1.00 1.00 0.99 0.99 1.00 1.00 1.00 *FV4CN(B,F)005 FV4CNB006 CAP**4817A** CAP**4821A** CAP**4823A** CAP**4824A** CAP**6021A** CAP**6024A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** CAP**4817A** CAP**4821A** CAP**6021A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CSPH*4812A** CSPH*6012A** CAP**4817A** CAP**4821A** CAP**4824A** CAP**6021A** CAP**6024A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** CAP**4821A** CAP**4824A** CAP**6021A** CAP**6024A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** Heating Indoor Model 1.01 0.98 1.00 1.00 1.00 0.99 1.00 1.00 1.00 1.00 1.00 1.02 1.00 1.02 0.99 1.01 1.02 1.02 1.01 1.01 1.02 1.01 1.01 1.02 1.03 1.02 1.01 1.02 1.03 1.02 1.02 1.03 1.02 1.03 1.02 1.05 1.05 1.04 1.05 1.06 1.06 1.05 1.05 1.06 1.05 1.05 1.06 1.06 1.06 1.04 0.97 1.00 Power 0.99 0.97 0.97 0.96 0.96 1.02 0.97 0.96 0.97 0.97 0.96 0.96 0.99 0.99 0.98 0.97 0.97 0.97 1.02 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.99 0.99 0.96 0.99 0.97 0.96 0.97 0.96 0.97 1.03 1.02 1.02 1.01 1.01 1.01 1.03 1.01 1.01 1.03 1.03 1.02 1.02 1.02 1.03 1.01 Low Speed Cap. 1.00 1.01 1.00 1.02 1.03 1.03 0.98 1.02 1.03 1.03 1.03 1.04 1.04 1.00 1.01 1.01 1.02 1.04 1.04 0.99 1.02 1.04 1.03 1.03 1.04 1.05 1.03 1.00 1.01 1.04 1.00 1.03 1.04 1.03 1.04 1.04 1.07 1.08 1.00 1.01 1.02 1.04 1.07 1.01 1.04 1.08 1.08 1.09 1.09 1.09 1.08 0.96 0.98 Power 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 315(A,J)AV048090 Furnace Model CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CAP**4817A** CSPH*6012A** CSPH*4812A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6021A** CAP**4821A** CAP**4817A** CAP**6025A** CAP**4823A** CAP**6025A** CAP**4823A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CSPH*6012A** Heating Indoor Model 1.01 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.01 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.02 1.01 1.01 1.01 1.01 1.01 1.01 1.00 1.02 1.01 1.00 1.00 1.00 0.99 0.99 0.99 1.00 0.99 0.99 1.00 1.00 0.99 0.99 High Speed Cap. 1.00 0.98 0.99 1.00 1.00 0.99 0.99 1.00 0.99 0.99 1.00 1.01 1.00 1.01 0.99 1.00 1.01 1.01 1.00 1.00 1.01 1.00 1.00 1.01 1.02 1.01 1.01 1.03 1.04 1.03 1.03 1.04 1.03 1.04 1.03 1.02 1.03 1.04 1.04 0.99 1.00 0.97 0.99 1.00 1.00 0.99 0.99 1.00 1.00 1.00 1.00 1.00 0.99 Power 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.01 1.01 1.04 1.04 1.01 1.04 0.99 1.04 1.04 1.04 1.04 1.00 1.00 0.99 0.99 1.02 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.02 1.01 0.99 0.99 0.97 0.97 0.96 0.96 1.01 0.97 0.96 0.97 0.97 0.96 0.96 Low Speed Cap. 0.99 0.96 0.97 0.99 0.99 0.98 0.97 0.99 0.98 0.98 0.99 0.99 1.00 1.02 0.97 1.00 0.99 1.02 1.00 1.00 1.02 0.99 0.99 1.00 1.01 1.00 1.00 1.01 1.01 1.00 0.99 1.01 1.00 1.02 1.01 1.00 1.02 1.00 1.02 0.99 0.99 1.00 1.02 1.03 1.03 0.98 1.02 1.03 1.02 1.02 1.03 1.04 0.99 Power 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 353AAV048080 359BAV060100 359BAV060100 359BAV060080 359BAV060080 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066135 Furnace Model 226ANA048---AOutdoor Section With FV4CNF003 Indoor Section HEAT PUMP HEATING PERFROMANCE CONTINUED 226A CNPH*6024A** CNPH*4821A** CSPH*6012A** CSPH*4812A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CAP**4817A** CSPH*6012A** CSPH*4812A** CNPV*6124A** CNPV*6024A** CNPV*4824A** CNPV*4821A** CNPH*6124A** CNPH*6024A** CNPH*4821A** CAP**6024A** CAP**6021A** CAP**4824A** CAP**4821A** CAP**4817A** CSPH*6012A** CSPH*4812A** CSPH*4812A** Heating Indoor Model 1.01 1.00 1.03 1.02 1.02 1.03 1.02 1.02 1.00 1.00 1.01 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.00 1.00 1.01 1.01 1.00 1.01 1.01 1.00 1.01 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 High Speed Cap. 1.00 1.02 1.02 1.07 1.08 1.08 1.07 1.07 1.08 1.00 1.02 1.00 1.02 1.02 1.02 1.02 1.02 1.02 1.01 1.02 1.03 1.03 1.02 1.04 1.01 1.03 1.03 1.03 1.02 1.03 1.03 1.03 1.03 1.03 1.05 1.04 1.02 1.03 1.00 1.03 1.04 1.04 1.02 1.03 1.04 1.03 1.03 1.04 1.04 1.03 0.99 1.00 1.00 Power 1.01 1.00 1.01 1.01 1.01 1.01 1.01 1.01 0.99 0.99 0.98 0.97 0.97 0.97 1.02 0.97 0.97 0.97 0.97 0.96 0.97 1.00 1.00 1.00 1.00 0.99 0.99 1.02 1.00 0.99 1.00 1.00 0.99 0.99 1.00 1.00 0.99 0.98 0.97 0.97 0.97 0.98 0.97 0.97 0.97 0.97 0.97 0.97 0.97 1.02 1.02 Low Speed Cap. 1.02 0.99 1.00 1.02 1.03 1.03 1.02 1.02 1.03 1.00 1.01 1.01 1.03 1.04 1.04 1.00 1.03 1.04 1.03 1.03 1.04 1.05 1.00 1.02 0.98 1.00 1.01 1.01 1.01 1.00 1.01 1.01 1.01 1.02 1.02 1.01 1.01 1.02 1.02 1.03 1.05 1.05 1.04 1.03 1.05 1.04 1.04 1.05 1.06 1.04 0.97 0.99 0.99 Power 313*AV048090 313*AV048090 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 313*AV048070 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 353AAV060120 353AAV060120 353AAV060120 Furnace Model 50 1.00 1.00 1.01 1.01 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.01 1.00 1.01 CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** 1.00 1.00 1.00 1.00 0.99 0.99 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.01 1.00 1.00 CAP**4821A** CAP**4824A** CAP**6021A** CAP**6024A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CAP**4817A** CAP**4821A** CAP**4824A** CAP**6021A** CAP**6024A** CNPH*4821A** CNPH*6024A** CNPH*6124A** CNPV*4821A** CNPV*4824A** CNPV*6024A** CNPV*6124A** CSPH*4812A** CSPH*6012A** See notes on pg. 52 1.00 CAP**4817A** Heating Indoor Model High Speed Cap. 1.01 1.01 1.02 1.00 1.02 1.03 1.03 1.02 1.02 1.03 1.02 1.02 1.03 1.03 1.03 0.99 1.01 1.01 1.01 1.01 1.01 1.02 1.03 1.01 1.00 1.01 0.99 1.00 1.01 1.01 1.00 1.00 1.01 0.99 1.01 0.98 1.00 1.01 1.01 0.99 1.00 1.01 1.01 1.01 0.99 1.02 1.02 1.02 1.01 Power 1.01 1.01 1.02 1.01 1.01 1.01 1.02 1.01 1.01 1.01 1.01 1.01 1.01 1.02 1.02 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.04 1.03 1.04 1.04 1.03 1.03 1.04 1.04 1.03 1.01 1.00 1.01 1.01 1.00 1.00 Low Speed Cap. 1.01 1.00 1.01 0.99 1.00 1.01 1.01 1.00 1.00 1.01 1.00 1.00 1.02 1.02 1.02 0.98 0.99 1.01 1.01 0.99 0.99 1.01 1.01 1.01 0.99 1.00 0.97 0.98 1.00 1.00 0.99 0.98 1.00 0.99 1.01 0.98 1.00 1.01 1.01 0.99 1.00 1.01 0.99 1.00 0.97 0.99 1.00 1.00 0.99 Power 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 313*AV048090 Furnace Model 226ANA048---AOutdoor Section With FV4CNF003 Indoor Section HEAT PUMP HEATING PERFROMANCE CONTINUED 226A 51 28.16 28.32 28.61 26.89 27.41 27.57 27.86 26.10 26.60 26.78 27.07 1835 2000 1500 1750 1835 2000 1500 1750 1835 2000 15.94 16.20 16.48 16.63 15.20 15.50 15.73 15.90 13.54 13.83 14.07 14.22 1250 1400 1500 1100 1250 1400 1500 1100 1250 1400 1500 Total 1100 CFM 7 ( ---13.9) 24.88 24.61 24.45 23.98 25.60 25.33 25.19 24.71 26.29 26.03 25.88 25.38 Integ} 13.07 12.93 12.70 12.44 14.61 14.45 14.24 13.96 15.28 15.14 14.89 14.65 Integ* Capacity MBtuh 27.62 Total 1750 See notes on pg. 52 80 (26.7) 70 (21.1) 65 (18.3) EDB ° F (° C) 7 ( ---13.9) Capacity MBtuh 1500 CFM INDOOR AIR 75 (23.9) 70 (21.1) 65 (18.3) EDB ° F (° C) INDOOR AIR 3.11 3.11 3.12 3.13 2.80 2.80 2.81 2.83 2.65 2.65 2.66 2.68 Total System KW† 3.77 3.76 3.75 3.76 3.59 3.58 3.58 3.58 3.42 3.41 3.41 3.41 Total System KW† 17 ( ---8.3) 31.27 30.94 30.74 30.16 32.76 32.50 32.35 31.07 33.17 32.97 32.83 32.39 Integ* 19.82 19.63 19.31 18.92 21.50 21.30 21.02 20.60 22.23 22.08 21.73 21.40 Total 18.08 17.90 17.61 17.25 19.60 19.42 19.17 18.79 20.27 20.13 19.81 19.51 Integ* Capacity MBtuh 34.30 33.94 33.72 33.08 35.93 35.64 35.49 34.08 36.38 36.16 36.00 35.52 Total Capacity MBtuh 17 ( ---8.3) 3.19 3.19 3.21 3.24 2.87 2.88 2.90 2.93 2.71 2.72 2.74 2.78 Total System KW† 3.98 3.98 3.99 4.01 3.84 3.84 3.85 3.84 3.66 3.66 3.67 3.69 Total System KW† 37 (2.8) OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C) 47 (8.3) 27 ( ---2.8) 37.61 37.30 37.17 36.62 38.11 37.82 37.66 37.15 38.62 38.35 38.18 37.65 Integ* 50.12 49.74 49.50 48.76 50.83 50.44 50.22 49.47 51.54 51.16 50.94 50.18 45.61 45.27 45.05 44.37 46.26 45.90 45.70 45.02 46.91 46.55 46.35 45.66 4.52 4.55 4.56 4.65 4.32 4.34 4.36 4.44 4.12 4.15 4.16 4.24 58.88 58.40 58.12 57.17 59.76 59.28 59.00 58.04 60.65 60.13 59.87 58.90 Total System KW† Total Integ* Capacity MBtuh 37 (2.8) Total System KW† 25.92 25.68 25.31 24.81 27.65 27.38 27.02 26.53 28.43 28.22 27.81 27.36 23.02 22.80 22.48 22.04 24.56 24.32 23.99 23.56 25.25 25.07 24.70 24.30 3.26 3.28 3.31 3.36 2.94 2.95 2.99 3.04 2.78 2.80 2.83 2.88 32.69 32.33 31.85 31.21 34.98 34.56 33.81 33.12 36.04 35.83 35.44 34.24 29.75 29.42 28.98 28.40 31.83 31.45 30.76 30.14 32.80 32.60 32.25 31.16 3.35 3.37 3.43 3.50 3.03 3.05 3.09 3.17 2.90 2.93 2.98 3.01 47 (8.3) 58.88 58.40 58.12 57.17 59.76 59.28 59.00 58.04 60.65 60.13 59.87 58.90 Total 40.77 40.48 40.00 39.01 42.07 41.80 41.36 40.76 42.73 42.46 41.99 41.42 3.51 3.55 3.63 3.72 3.15 3.19 3.26 3.37 2.99 3.02 3.09 3.19 Total System KW† 4.82 4.86 4.88 5.00 4.60 4.65 4.67 4.78 4.40 4.43 4.47 4.57 Total System KW† 226A 40.77 40.48 40.00 39.01 42.07 41.80 41.36 40.76 42.73 42.46 41.99 41.42 Integ* Capacity MBtuh OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C) 4.26 4.27 4.28 4.34 4.07 4.08 4.09 4.14 3.88 3.89 3.90 3.95 226ANA060---A---LO Outdoor Section With FV4CNB006 Indoor Section Total Capacity MBtuh 42.34 42.00 41.85 41.23 42.91 42.58 42.40 41.83 43.49 43.18 42.99 42.40 Total Total Capacity MBtuh Capacity MBtuh System System Total Integ* Total Integ* Total Integ* KW† KW† 226ANA060---A Outdoor Section With FV4CNB006 Indoor Section Capacity MBtuh 27 ( ---2.8) HEAT PUMP HEATING PERFORMANCE CONTINUED 57 (13.9) 57 (13.9) 68.75 68.25 67.96 66.82 69.68 69.20 68.90 67.81 70.59 70.13 69.84 68.78 Integ* 47.79 47.45 46.85 46.10 49.43 49.05 48.43 47.67 50.26 49.89 49.25 48.46 Total 47.79 47.45 46.85 46.10 49.43 49.05 48.43 47.67 50.26 49.89 49.25 48.46 Integ* Capacity MBtuh 68.75 68.25 67.96 66.82 69.68 69.20 68.90 67.81 70.59 70.13 69.84 68.78 Total Capacity MBtuh 3.61 3.66 3.77 3.91 3.25 3.30 3.39 3.52 3.09 3.13 3.22 3.34 Total System KW† 5.11 5.17 5.21 5.37 4.90 4.96 4.99 5.15 4.70 4.75 4.79 4.94 Total System KW† 67 (19.4) 67 (19.4) 79.17 78.70 78.39 77.15 80.16 79.70 79.40 78.25 81.13 80.72 80.44 79.32 Integ* 55.71 55.31 54.59 53.60 57.43 57.01 56.29 55.36 58.26 57.88 57.16 56.24 Total 55.71 55.31 54.59 53.60 57.43 57.01 56.29 55.36 58.26 57.88 57.16 56.24 Integ* Capacity MBtuh 79.17 78.70 78.39 77.15 80.16 79.70 79.40 78.25 81.13 80.72 80.44 79.32 Total Capacity MBtuh 3.72 3.79 3.92 4.09 3.37 3.42 3.54 3.70 3.20 3.26 3.36 3.52 Total System KW† 5.51 5.59 5.64 5.84 5.29 5.36 5.41 5.61 5.08 5.15 5.19 5.39 Total System KW† 52 1.01 1.00 1.00 1.00 0.99 1.00 0.99 1.00 1.00 1.00 1.00 0.99 CNPV*6124A** CSPH*6012A** CAP**6021A** CAP**6024A** CNPH*6024A** CNPH*6124A** CNPV*6024A** CNPV*6124A** CSPH*6012A** CAP**6021A** CAP**6024A** CNPH*6024A** 1.08 1.08 1.02 1.00 1.03 1.02 1.03 1.03 1.03 1.02 1.01 1.03 1.03 1.03 1.04 1.04 1.03 1.03 1.05 1.05 1.05 1.05 1.05 1.05 1.04 1.06 1.05 1.07 1.06 1.06 1.00 Power 1.00 1.01 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.99 0.98 0.99 0.98 0.98 0.98 1.02 1.02 1.04 1.02 1.01 1.01 1.01 Low Speed Cap. 1.00 1.05 1.07 1.03 1.02 1.04 1.03 1.04 1.04 1.04 1.03 1.02 1.04 1.03 1.04 1.04 1.04 1.04 1.03 1.04 1.05 1.04 1.05 1.05 1.11 1.10 1.19 1.11 1.11 1.10 1.10 1.01 Power 359BAV060100 359BAV060080 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066155 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV066135 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 315(A,J)AV060110 Furnace Model CAP**6021A** 1.02 1.01 CSPH*6012A** 1.01 1.02 1.01 1.01 1.01 1.02 1.02 1.02 1.03 1.02 1.02 1.02 1.00 1.00 0.99 1.00 0.99 0.99 0.99 1.00 1.00 0.99 1.00 0.99 0.99 0.99 1.00 1.00 1.00 CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPH*6124A** CNPH*6024A** High Speed Cap. 1.00 1.07 1.07 1.09 1.08 1.09 1.09 1.09 1.08 1.07 1.10 1.09 1.10 1.10 1.10 1.02 1.01 1.03 1.03 1.03 1.03 1.03 1.03 1.02 1.04 1.04 1.04 1.04 1.04 1.05 1.06 1.07 1.07 Power 0.98 0.99 0.98 0.99 0.98 0.98 0.98 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 1.01 1.01 1.00 1.01 1.00 1.00 1.00 0.98 0.98 0.98 Low Speed Cap. 0.98 1.06 1.06 1.07 1.07 1.07 1.07 1.07 1.07 1.05 1.07 1.06 1.07 1.07 1.07 1.03 1.01 1.03 1.03 1.03 1.04 1.04 1.05 1.03 1.04 1.05 1.04 1.04 1.05 1.06 1.06 1.06 1.07 Power 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060100 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 355(A,C)AV060080 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060120 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV060100 353AAV048080 353AAV048080 353AAV048080 353AAV048080 Furnace Model 226ANA060---A Outdoor Section With FV4CNB006 Indoor Section Heating Indoor Model CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CNPV*6124A** CNPV*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** CSPH*6012A** CNPV*6124A** CNPV*6024A** CNPH*6124A** CNPH*6024A** CAP**6024A** CAP**6021A** Heating Indoor Model 1.02 1.02 1.01 1.02 1.01 1.02 1.02 1.01 1.00 1.01 1.01 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.00 1.01 1.00 1.01 High Speed Cap. 1.01 1.07 1.06 1.08 1.07 1.08 1.09 1.09 1.03 1.05 1.06 1.06 1.03 1.03 1.05 1.04 1.05 1.05 1.05 1.02 1.02 1.04 1.03 1.04 1.04 1.04 1.05 1.04 1.06 1.06 1.06 1.07 1.07 Power 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.99 0.99 0.99 0.99 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.98 0.99 0.98 0.99 0.98 0.98 Low Speed Cap. 0.98 1.05 1.04 1.06 1.05 1.06 1.06 1.06 1.03 1.05 1.05 1.05 1.04 1.02 1.04 1.04 1.04 1.05 1.05 1.03 1.01 1.04 1.03 1.04 1.04 1.04 1.05 1.04 1.05 1.06 1.05 1.05 1.05 Power 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 374RAN060120 368RAN060120 368RAN060120 368RAN060120 368RAN060120 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060135 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 313*AV060110 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 355(A,C)AV060120 Furnace Model NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. * Tested Combination } The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity. { The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts. EDB — Entering Dry Bulb 1.02 1.00 CNPV*6024A** CAP**6025A** 1.01 CNPH*6124A** 1.02 1.00 CNPH*6024A** CAP**6025A** 1.00 CAP**6024A** 1.00 1.00 CAP**6021A** CSPH*6012A** 1.01 CSPH*6012A** 1.00 1.02 CNPV*6124A** CNPV*6124A** 1.02 CNPV*6024A** 0.99 1.02 CNPH*6124A** CNPV*6024A** 1.01 CNPH*6024A** 1.00 1.01 CAP**6024A** CNPH*6124A** 1.01 High Speed Cap. 1.00 CAP**6021A** *FV4CNB006 Heating Indoor Model HEAT PUMP HEATING PERFORMANCE CONTINUED 226A GUIDE SPECIFICATIONS GENERAL System Description — — — — Compressor Quality Assurance — — — — — — — Unit will be rated in accordance with the latest edition of AHRI Standard 240. Unit will be certified for capacity and efficiency, and listed in the latest ARI directory. Unit construction will comply with latest edition of ASHRAE and with NEC. Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have C--UL approval. Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500--hr salt spray test. Air--cooled condenser coils are pressure tested and the outdoor units are leak tested. Unit constructed in ISO9001 approved facility. — — — Condenser Coil — — Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations. Warranty (for inclusion by specifying engineer) — — — — U.S. and Canada only. Equipment — Factory--assembled, single--piece, air--cooled heat pump unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puronr (R--410A) refrigerant, and special features required prior to field start--up. — Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint. The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ _F (_C). The power consumption at full load will not exceed _____ kW. Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ _F (_C) wet bulb and _____ _F (_C) dry bulb, and air entering the unit at _____ _F (_C). The system will have a SEER of _____ Btuh/watt or greater at DOE conditions. Electrical Requirements — Fans — Refrigeration circuit components will include liquid--line back--seating shutoff valve with sweat connections, vapor--line back--seating shutoff valve with sweat connections, system charge of Puronr (R--410A) refrigerant, POE compressor oil, accumulator, and reversing valve. Unit will be equipped with high--pressure switch, loss-of--charge switch, and filter drier for Puronr refrigerant. Operating Characteristics PRODUCTS — Condenser coil will be air cooled. Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed. Refrigeration Components Delivery, Storage, and Handling — Compressor will be hermetically sealed. Compressor will be mounted on rubber vibration isolators. Compressor will be covered with a sound absorbing blanket. Condenser fan will be direct--drive propeller type, forward swept blade, discharging air upward. — — Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. Unit electrical power will be single point connection. Control circuit will be 24v. Special Features — 53 Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 226A Outdoor--mounted, air--cooled, split--system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air--cooled coil, forward--swept blade propeller--type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. AIR--COOLED, SPLIT--SYSTEM HEAT PUMP 226A 2 TO 5 NOMINAL TONS Condenser fan motors will be totally enclosed, 1--phase type with class B insulation and permanently lubricated. Shafts will be corrosion resistant. Fan blades will be statically and dynamically balanced. Condenser fan openings will be equipped with coated steel wire safety guards. 226A SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc. 2. Minimum outdoor operating air temperature without low--ambient operation accessory is 55_F (12.8_C). 3. The maximum outdoor operating ambient in cooling mode is 125_F (51.67_C) when operating voltage is 230v. For 208v applications, the maximum outdoor ambient is 120_F (48.9_C). 4. Minimum outdoor operating air temperature for heating mode is –30_F (–34.4_C). 5. Maximum outdoor operating air temperature for heating mode is 66_F (18.9_C). 6. For reliable operation, unit should be level in all horizontal planes. 7. For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or elevation differences between indoor and outdoor units greater than 20 ft (6.1 m), consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor. 8. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4 mm). 9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 10. Do not apply capillary tube indoor coils to these units. 11. Factory--supplied filter drier must be installed. EBryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 08/09 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 54 Catalog No. PDS226A ---01 Replaces: New
Documentos relacionados
Product Data - Classic Air Conditioning
COND FAN Forward Swept Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM)
Leia maisProduct Data - Classic Air Conditioning
HP WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size
Leia maisProduct Data - American Cooling and Heating
insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70). } Length shown is as measured 1 way along w...
Leia mais