PKZ2 - Atlas Comercial
Transcrição
PKZ2 - Atlas Comercial
08/000 Motor-Protective Circuit-Breakers Motor-Protective Circuit-Breakers Moeller HPL0211-2001/2002 08/028 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers System Overview Motor protection, distribution circuit protection, protection of cables and conductors Moeller HPL0211-2001/2002 Moeller HPL0211-2001/2002 08/029 Basic units Motor-protective circuit-breakers Rated operational current 40 A 18.5 kW/415 V Switching capacity 30 kA/415 V Overload releases, adjustable Short-circuit releases, adjustable Phase-failure sensitivity Thumb-grip lockable by means of a padlock (hasp thickness 4 – 6 mm o) ZMR trip block with overload relay function Finger-proof terminals Add-on functions 1 a Page 08/032 Circuit-breakers Rated operational current 40 A Switching capacity 30 kA/415 V Overload releases, adjustable Short-circuit releases, adjustable Thumb-grip lockable by means of a padlock (hasp thickness 4 – 6 mm o) 3- and 4-pole versions available Finger-proof terminals Contact module Function and characteristics of a contactor When fitted to motor-protective circuitbreakers produces compact starters to Type “1” coordination Can be fitted to 3- or 4-pole circuitbreakers, profiles match Built-in auxiliary contacts, 1 M, 1 B or 2 M Can be mounted separately, e. g. for use in reversing starters SE1A-G-10-PKZ2 contact module for actuation with 24 V DC 6 Remote operators Remote On/Off motor-protective circuit-breakers Remote reset motor-protective circuit-breakers AC and DC voltages Hand/Auto operation Hand/Auto indicating contact RS-PKZ2 remote operator is suitable for 24 V DC actuation directly from a PLC 5 a Page 08/044 Mounting accessories a Page 08/046 1 High-capacity contact module As for contact module Increases the switching capacity to Iq = 100 kA/500 V When fitted to motor-protective circuitbreakers produces high-capacity compact starters to Type “2” coordination S-G-PKZ2 high-capacity contact module for actuation with 24 V DC 7 Mounting/wiring Clip plate can be snap fitted to EN 50 022 top-hat rails With integral screw fixing Three-phase commoning link for series mounting of two or three circuit-breakers Component adapter for busbar mounting 2 Reversing combination with short-circuit proof three-phase commoning links a Page 08/046 a Page 08/051 Auxiliary contacts 10 On/Off indication for motor-protective circuit-breaker Differential fault indication overload/ short-circuit trip On/Off for (high-capacity) contact module On/Off for motor-starter combination Door coupling handle, IP65 Indication of switch position On/Off/Tripped Lockable by means of 3 padlocks Integral door/cover interlock Plug-fit extension shaft to facilitate fitting a Page 08/040 a Page 08/050 a Page 08/032 Current limiter module Increases the switching capacity to 100 kA/500 V Can be mounted separately for group protection 8 Insulated enclosures Surface mounting enclosures, IP40 and IP54 Flush mounting enclosures, Front IP41 and IP54 a Page 08/040 a Page 08/050 Voltage releases Undervoltage releases – with early-make auxiliary contacts – Off-delayed with early-make auxiliary contacts Shunt release 4 a Page 08/042 Product attributes Main switch and isolating characteristics 3- and 4-pole circuit-breakers with protected neutral pole Plug-in trip block Visible isolating gap Modular system Remote operation – motor-protective circuit-breaker Differential fault indication via trip-indicating auxiliary contacts 9 3-pole (high-capacity) contact module can be fitted, profiles match 3-pole current limiter can be fitted, profiles match Worldwide approval 3 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers System Overview Motor-Protective Circuit-Breakers Type – Front IP54 E 54-PKZ2 R(H)-PKZ 2 door coupling handle additionally required as standard IP40 IP54 CI19 EA-PKZ2 CI19 EB-PKZ2 Insulated enclosures for surface mounting Front IP41 Notes PKZ2/ZM-.../SE1A/11 PKZ2/ZM-.../S Degree of protection E-PKZ2 Insulated enclosures for flush mounting IP54 CI23 EB-PKZ 2 or or or – – – – – – – – – NHI11 S-PKZ2 NHI22 S-PKZ2 NHI2-11 S-PKZ2 Standard auxiliary contacts (H-) compact starter NHI11-PKZ2 NHI22-PKZ2 Standard auxiliary contacts Modules Moeller HPL0211-2001/2002 The possible combinations of motor-protective circuit-breakers or (high-capacity) compact starters with enclosures or modules are indicated by . IP40 CI23 EA-PKZ2 Insulated enclosures for surface mounting – Compact starters, high-capacity compact starters PKZ2/ZM-...(-8) Motor-protective circuit-breakers, circuit-breakers Type Enclosures PKZ2 Motor-Protective Circuit-Breakers Overview of Combinations 08/030 – – – – – – – RE-PKZ2 RS-PKZ2 or or Remote operators – AGM2-11-PKZ2 Trip-indicating auxiliary contacts or or or or or – – or – or or or or or or or or or or U-HI20-PKZ2 – U-PKZ2 UVHI-PKZ2 Undervoltage release PKZ2 Motor-Protective Circuit-Breakers Overview of Combinations – – A-PKZ2 Shunt release – – – – – – H-PKZ2 RH-PKZ2 Door coupling handle Moeller HPL0211-2001/2002 – – – – – – L-PKZ0 Indicator light 08/031 Motor-Protective Circuit-Breakers Motor-Protective Circuit-Breakers Notes Ι> 1) 1.5 3 4 9 12.5 17.5 22 1.5 2.2 4 7.5 12.5 15 20 1.1 2.2 4 5.5 7.5 11 World market devices to IECqUL/CSA For protection of cables and conductors Circuit-breakers 1.1 0.75 0.75 0.55 0.55 0.25 0.37 0.25 0.25 0.12 Ι> 0.18 kW 0.12 kW Motor-protective circuit-breakers1), Type “2” coordination 0.09 kW Max. AC-3 motor rating 380 V 220 V 440 V 400 V 230 V 415 V 240 V PKZ2 Motor-Protective Circuit-Breakers Motor-Protective Circuit-Breakers, Circuit-Breakers 08/032 24 22 15 9 5.5 3 2.2 1.1 0.75 0.37 0.25 kW 500 V 30 22 22 12.5 7.5 4 3 1.5 1.1 0.55 0.25 kW 660 V 690 V 24 – 32 32 – 40 16 – 25 25 40 10 – 16 16 32 6 – 10 32 – 40 24 – 32 16 – 25 10 – 16 6 – 10 4–6 2.4 – 4 1.6 – 2.4 1 – 1.6 0.6 – 1 0.4 – 0.6 Ir A 10 40 32 25 16 10 6 4 2.4 1.6 1 0.6 Iu A 200 – 350 160 – 280 130 – 210 80 – 140 50 – 80 350 – 500 275 – 425 200 – 350 130 – 220 80 – 140 50 – 80 35 – 55 20 – 35 14 – 22 8 – 14 5–8 Irm A Rated Setting range uninterrupted Overload Short-circuit current release release Moeller HPL0211-2001/2002 PKZ2/ZM-10-8 050335 PKZ2/ZM-16-8 052708 PKZ2/ZM-25-8 055081 PKZ2/ZM-32-8 057454 PKZ2/ZM-40-8 059827 PKZ2/ZM-25 043216 PKZ2/ZM-32 045589 PKZ2/ZM-40 047962 PKZ2/ZM-0,6 021859 PKZ2/ZM-1 026605 PKZ2/ZM-1,6 028978 PKZ2/ZM-2,4 031351 PKZ2/ZM-4 033724 PKZ2/ZM-6 036097 PKZ2/ZM-10 038470 PKZ2/ZM-16 040843 Type Article no. – – – – – – – – – – – – – – – – Price See Price List 1 off 1 off Std. pack Adjustable short-circuit release Irm = 5.0–8.5 x Iu Factory-set to 5 xIu Adjustable overload release Ir = 0.6–1.0 xIu 6 Can be snap fitted to an EN 50 022 top-hat rail, height 7.5 or 15 mm Rated ultimate short-circuit breaking capacity a Page 08/075 08/040 08/051 08/050 08/042 08/044 08/046 Page 8 7 08/040 08/040 9 3 Standard auxiliary contacts 5 Trip-indicating auxiliary contacts 6 Shunt releases Undervoltage releases 7 Remote operators 8 Contact module High-capacity contact module Current limiter 9 Clip plate Additional accessories 3 08/033 Accessories 5 Notes Moeller HPL0211-2001/2002 Adjustable short-circuit release Irm = 8.5 – 14 x Iu Factory set to 12 x Iu Adjustable overload release Ir = 0.6–1.0 xIu Phase-failure sensitivity to IEC/EN 60 947-4-1 PKZ2 Motor-Protective Circuit-Breakers Motor-Protective Circuit-Breakers, Circuit-Breakers Motor-Protective Circuit-Breakers Motor-Protective Circuit-Breakers T A1 13 21 A2 14 22 Notes T Ι >> Ι > L A2 14 22 A1 13 21 1) 4 9 12.5 17.5 4 7.5 12.5 15 18.5 2.2 4 5.5 7.5 11 3 4 9 12.5 17.5 22 2.2 4 7.5 12.5 15 18.5 4 5.5 7.5 11 1.5 1.1 2.2 1,5 0.75 1.1 0.75 0.37 0.25 0.55 0.25 0.55 0.12 0.25 22 3 1.5 2.2 1.5 0.75 1.1 1.1 0.75 0.55 0.55 0.25 0.37 0.25 0.25 kW 0.12 kW World market devices to IEC q UL/CSA High-capacity compact starters1), Type “2“ coordination Ι> L Compact starters1), Type “1” coordination kW Max. AC-3 motor rating 380 V 220 V 440 V 400 V 230 V 415 V 240 V PKZ2 Motor-Protective Circuit-Breakers Compact Starters, High-Capacity Compact Starters 08/034 24 22 15 9 5.5 3 2.2 1.1 0.75 0.37 24 22 15 9 5.5 3 2.2 1.1 0.75 0.37 kW 500 V 30 22 22 12.5 7.5 4 3 1.5 1.1 0.55 30 22 22 12.5 7.5 4 3 1.5 1.1 0.55 kW 660 V 690 V 36 32 25 16 10 6 4 2.4 1.6 1 36 32 25 16 10 6 4 2.4 1.6 1 32 – 40 24 – 32 16 – 25 10 – 16 6 – 10 4–6 2.4 – 4 1.6 – 2.4 1 – 1.6 0.6 – 1 32 – 40 24 – 32 16 – 25 10 – 16 6 – 10 4–6 2.4 – 4 1.6 – 2.4 1 – 1.6 0.6 – 1 Ir A Iu A 350 – 500 275 – 425 200 – 350 130 – 220 80 – 140 50 – 80 35 – 55 20 – 35 14 – 22 8 – 14 350 – 500 275 – 425 200 – 350 130 – 220 80 – 140 50 – 80 35 – 55 20 – 35 14 – 22 8 – 14 Irm A Setting range Overload Short-circuit release release Rated uninterrupted current Moeller HPL0211-2001/2002 PKZ2/ZM-25/S(230V50HZ) 063542 PKZ2/ZM-32/S(230V50HZ) 063552 PKZ2/ZM-40/S(230V50HZ) 063562 PKZ2/ZM-1/S(230V50HZ) 063472 PKZ2/ZM-1,6/S(230V50HZ) 063482 PKZ2/ZM-2,4/S(230V50HZ) 063492 PKZ2/ZM-4/S(230V50HZ) 063502 PKZ2/ZM-6/S(230V50HZ) 063512 PKZ2/ZM-10/S(230V50HZ) 063522 PKZ2/ZM-16/S(230V50HZ) 063532 PKZ2/ZM-25/SE1A/11(230V50HZ) 063432 PKZ2/ZM-32/SE1A/11(230V50HZ) 063442 PKZ2/ZM-40/SE1A/11(230V50HZ) 063452 PKZ2/ZM-1/SE1A/11(230V50HZ) 063364 PKZ2/ZM-1,6/SE1A/11(230V50HZ) 063372 PKZ2/ZM-2,4/SE1A/11(230V50HZ) 063382 PKZ2/ZM-4/SE1A/11(230V50HZ) 063392 PKZ2/ZM-6/SE1A/11(230V50HZ) 063402 PKZ2/ZM-10/SE1A/11(230V50HZ) 063412 PKZ2/ZM-16/SE1A/11(230V50HZ) 063422 Type Article no. – – – – – – – – – – – – – – – – – – – – Price See Price List 1 off 1 off Std. pack High-capacity contact module has built-in auxiliary contacts: 1 M/1 B Rated short-circuit current Iq = 100 kA/400 V Other voltages a Page 08/057 7 6 08/057 08/042 08/044 08/051 08/050 09/004 Supplied fitted to C-PKZ2 clip plate, can be snap fitted to one or two EN 50 022 top-hat rails, height 15 mm Adjustable short-circuit release Irm = 8.5 – 14 x Iu Factory-set to 12 x Iu Adjustable overload release Ir = 0.6 – 1.0 x Iu Phase-failure sensitivity to IEC/EN 60 947-4-1 Suitable for the protection of EEx e-motors PTB certificate no.: 3.53-388.299 Standard auxiliary contacts Standard auxiliary contacts Trip-indicating auxiliary contacts Shunt release Undervoltage release 7 Remote operator 9 Clip plate Additional accessories Fuseless motor-starter combinations Additional actuating voltages Page 9 08/040 08/040 08/040 4 Accessories 3 08/035 3 4 5 6 5 Notes Moeller HPL0211-2001/2002 Contact module has built-in auxiliary contacts: 1 M/1 B Other voltages a Page 08/057 PKZ2 Motor-Protective Circuit-Breakers Compact Starters, High-Capacity Compact Starters Motor-Protective Circuit-Breakers 08/036 Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Modules for Motor Protection Rated uninterrupted current Iu A Type Article no. Price See Price List Std. pack Notes 40 PKZ2 026606 – 1 off PKZ2 basic unit with S-PKZ2 highcapacity contact module fitted (1 B, 1 M) Supplied on C-PKZ2 clip plate can not be combined with Z...-0,6-PKZ2 36 PKZ2/S (230V50HZ) 063572 – PKZ2 basic unit with SE1A/11-PKZ2 contact module fitted (1 M, 1 B) Supplied on C-PKZ2 clip plate can not be combined with Z...-0,6-PKZ2 36 Basic unit, 3-pole Accessories a Page 08/050 Circuit diagram for ZM... PKZ2 Ι> PKZ2/SE1A/11(230V50HZ) 082142 – ZMR...PKZ2 H A Ι> 95 97 96 98 Selectable: H q Hand position or A q Auto position For EEx e applications, the 95/96 break contact must be used as standard to de-energize the (highcapacity) contact module or contactor. ZMR-...-PKZ2 motor-protective trip blocks cannot be combined with U/A voltage releases or RE/RS remote operators M...PKZ2 Ι> Other actuating voltages a Page 08/057 08/037 Moeller HPL0211-2001/2002 Max. AC-3 motor rating 220 V 380 V 440 V 500 V 230 V 400 V 240 V 415 V kW kW kW Motor-protective trip blocks, 3-pole 0.12 0.18 With overload 0.09 release 0.25 0.25 0.12 With overload relay function, with Hand/Auto position Without overload release 660 V 690 V Rated Setting range uninter- Overload Shortrupted release circuit current release kW kW Iu A Ir A 0.25 0.25 0.6 0.4 – 0.6 5 – 8 0.37 0.55 1 0.6 – 1 8 – 14 14 – 22 Type Article no. Price See Price List Std. pack ZM-0,6-PKZ2 024232 ZM-1-PKZ2 028979 ZM-1,6-PKZ2 031352 ZM-2,4-PKZ2 033725 ZM-4-PKZ2 036098 ZM-6-PKZ2 038471 ZM-10-PKZ2 040844 ZM-16-PKZ2 043217 – 1 off ZM-25-PKZ2 045590 ZM-32-PKZ2 047963 ZM-40-PKZ2 050336 – ZMR-0,6-PKZ2 033943 ZMR-1-PKZ2 033950 ZMR-1,6-PKZ2 033952 ZMR-2,4-PKZ2 033955 ZMR-4-PKZ2 033957 ZMR-6-PKZ2 033966 ZMR-10-PKZ2 033967 ZMR-16-PKZ2 033968 – ZMR-25-PKZ2 033969 ZMR-32-PKZ2 033973 ZMR-40-PKZ2 033975 – M-0,6-PKZ2 004537 M-1-PKZ2 004538 M-1,6-PKZ2 004539 M-2,4-PKZ2 004540 M-4-PKZ2 004541 M-6-PKZ2 004542 M-10-PKZ2 004543 M-16-PKZ2 004544 – M-25-PKZ2 004545 M-32-PKZ2 004546 M-40-PKZ2 004547 – Im A 0.25 0.55 0.55 0.75 1.1 1.6 1 – 1.6 0.37 0.75 1.1 1.1 1.5 2.4 1.6 – 2.4 20 – 35 0.75 1.5 1.5 2.2 3 4 2.4 – 4 35 – 55 1.1 2.2 3 3 4 6 4–6 50 – 80 2.2 4 4 5.5 7.5 10 6 – 10 80 – 140 4 7.5 9 9 12.5 16 10 – 16 130 – 220 5.5 12.5 12.5 15 22 25 16 – 25 200 – 350 7.5 15 17.5 22 22 32 24 – 32 275 – 425 11 20 22 24 30 40 32 – 40 350 – 500 0.09 0.12 0.18 0.25 0.25 0.6 0.4 – 0.6 5 – 8 0.12 0.25 0.25 0.37 0.55 1 0.6 – 1 8 – 14 0.25 0.55 0.55 0.75 1.1 1.6 1 – 1.6 14 – 22 0.37 0.75 1.1 1.1 1.5 2.4 1.6 – 2.4 20 – 35 0.75 1.5 1.5 2.2 3 4 2.4 – 4 35 – 55 1.1 2.2 3 3 4 6 4–6 50 – 80 2.2 4 4 5.5 7.5 10 6 – 10 80 – 140 4 7.5 9 9 12.5 16 10 – 16 130 – 220 5.5 12.5 12.5 15 22 25 16 – 25 200 – 350 7.5 15 17.5 22 22 32 24 – 32 275 – 425 11 20 22 24 30 40 32 – 40 350 – 500 0.6 – 5–8 1 – 8 – 14 1.6 – 14 – 22 2.4 – 20 – 35 4 – 35 – 55 6 – 50 – 80 10 – 80 – 140 16 – 130 – 220 25 – 200 – 350 32 – 275 – 425 40 – 350 – 500 – – – Phase-failure sensitivity to IEC/EN 60 947-4-1 Suitable for the protection of EEx e motors PTB certificate no.: 3.53-388.299 Adjustable overload release Ir = 0.6 – 1.0 x Iu – – Adjustable short-circuit release Irm = 8.5 – 14 x Iu Factory-set to 12 x Iu – – – – 1 off Phase-failure sensitivity and overload/shortcircuit release setting options and PTB, see above. When using motorprotective trip blocks with an overload relay function, the motorprotective circuitbreaker does not trip in the event of an overload. The overload indication is produced by means of two auxiliary contacts. Different potentials may be applied to the two auxiliary contacts. 1 off Adjustable short-circuit release Irm = 8.5 – 14 x Iu Factory-set to 12 x Iu – – – – – – – – – – – – – – – – – – Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Motor Protection Modules 08/038 Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Distribution Circuit Protection Modules Rated uninterrupted current Iu A Type Article no. Price See Price List Std. pack Notes 40 PKZ2 026606 – 1 off 40 PKZ24 004521 – 1 off Basic unit, 3-pole Basic unit, 4-pole Accessories a Page 08/050 Circuit diagram for ZM... -PKZ2(4) Ι> M... -PKZ2(4) Ι> 08/039 Moeller HPL0211-2001/2002 Rated uninterrupted current Iu A Setting range Overload release Short-circuit release Ir A Irm A Trip blocks for distribution circuit protection, 3-pole With overload release 10 6 – 10 50 – 80 Without overload release 16 10 – 16 80 – 140 25 16 – 25 130 – 210 32 24 – 32 160 – 280 40 32 – 40 200 – 350 10 50 – 80 16 80 – 140 25 130 – 210 32 160 – 280 40 200 – 350 Trip blocks for distribution circuit protection, 4-pole With overload releases 10 6 – 10 50 – 80 in all four poles 16 10 – 16 80 – 140 Without overload release 25 16 – 25 130 – 210 32 24 – 32 160 – 280 40 32 – 40 200 – 350 10 50 – 80 16 80 – 140 25 130 – 210 32 160 – 280 40 200 – 350 Type Article no. Price See Price List Std. pack ZM-10-8-PKZ2 062201 ZM-16-8-PKZ2 059828 ZM-25-8-PKZ2 057455 ZM-32-8-PKZ2 055082 ZM-40-8-PKZ2 052709 – 1 off M-10-8-PKZ2 004532 M-16-8-PKZ2 004533 M-25-8-PKZ2 004534 M-32-8-PKZ2 004535 M-40-8-PKZ2 004536 – ZM-10-8-PKZ24 004526 ZM-16-8-PKZ24 004525 ZM-25-8-PKZ24 004524 ZM-32-8-PKZ24 004523 ZM-40-8-PKZ24 004522 – M-10-8-PKZ24 004527 M-16-8-PKZ24 004528 M-25-8-PKZ24 004529 M-32-8-PKZ24 004530 M-40-8-PKZ24 004531 – – Adjustable overload release Ir = 0.6 – 1.0 x Iu Adjustable short-circuit release Irm = 5 – 8.5 x Iu, factory-set to 5 x Iu – – – Adjustable short-circuit release Irm = 5 – 8.5 x Iu, factory-set to 5 x Iu – – – – – – – 1 off Adjustable overload release Ir = 0.6 – 1.0 x Iu Adjustable short-circuit release Irm = 5 – 8.5 x Iu, factory-set to 5 x Iu PKZ24/ZM-...-8 circuit-breakers protect all 4 poles – – Adjustable short-circuit release Irm = 5 – 8.5 x Iu, factory-set to 5 x Iu – PKZ24/M-...-8 circuit-breakers protect in all 4 poles – – Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Distribution Circuit Protection Modules Motor-Protective Circuit-Breakers Moeller HPL0211-2001/2002 Contact sequence Circuit diagram 2B 2x1B 2x1M NHI2-11S L1L2L3 NHI2-11S L1L2L3 NHI11 L1L2L3 NHI2-11S L1L2L3 22 21 PKZ 2(4)/ZM.../S 14 13 PKZ 2(4)/ZM... I A2 A1 NHI11 NHI22 NHI 11S 1.14 1.22 1.13 1.21 1.14 1.22 1.13 1.21 1.14 1.22 1 B) AGM L1L2L3 trip "+" PKZ 2(4)/ZM... Ι "+" 4.44 4.32 AGM 2-11 4.43 4.31 Current limiters To increase the switching capacity of non-inherently shortcircuit-proof motor-protective circuit-breakers to 100 kA/500 V " " "+" L1L2L3 On/Off " " "+" L1L2L3 Trip "+" 4.22 4.21 4.14 4.13 "Ι >" 1.14 1.32 1.22 1.44 NHI 22S 1.21 1.43 1.13 1.31 1.32 1.44 1.31 1.43 1.14 32 1.22 44 NHI 2-11S 1.21 43 1.13 31 Ι>> T L Rated uninterrupted current Iu = 40 A For motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Short-circuit indicators 2 x (1 M For motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Trip-indicating auxiliary contact with short-circuit indicator 2B 2M For (high-capacity) compact starters 1M 1B 2M NHI11 oder L1L2L3 For motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters 1.13 1.21 1M 1B Standard auxiliary contacts Auxiliary contacts M= B= Make Break +CL-PKZ2 078812 +K-AGM-PKZ2 024234 +AGM2-11-PKZ2 019488 +NHI2-11S-PKZ2 012369 +NHI22S-PKZ2 002877 CL-PKZ2 076439 K-AGM-PKZ2 021861 AGM2-11-PKZ2 017115 NHI2-11S-PKZ2 009996 NHI22S-PKZ2 000504 NHI11S-PKZ2 007623 NHI22-PKZ2 097796 +NHI22-PKZ2 095423 Type Article no. When ordered separately NHI11-PKZ2 090677 +NHI11S-PKZ2 005250 Moeller HPL0211-2001/2002 – – – – – – – – – Price See Price List 1 off 1 off 1 off 1 off 1 off 1 off Std. pack Can be fitted to circuit-breaker or mounted separately on EZ base (a Page 08/046) Can be used for individual protection When fitted to circuit-breaker, C-PKZ2 clip plate required as standard Max. rated operational voltage Ue = 690 V Can be used in circuit-breakers and (high-capacity) compact starters Local short-circuit indication by resettable indicator. Differential remote indication: a) General trip indication “+”, overload, b) Short-circuit trip Can be fitted to circuit-breaker and (high-capacity) compact starter. Can be combined with NHI... or NHI...S standard auxiliary contacts When fitting to 4-pole starter combination, add neutral pole for (high-capacity) contact module (a Page 08/048) Can be combined with AGM tripindicating auxiliary contacts Can be fitted to starter combination Can be combined with AGM tripindicating auxiliary contacts Can be fitted to circuit-breaker and (high-capacity) compact starter. Accessories 7 Page 9 7 9 1 Motor-protective circuit-breaker Circuit-breaker 9 Clip plate Additional accessories Accessories 1 Current limiter 2 (High-capacity) compact starter 7 Remote operator 9 Clip plate Additional accessories Accessories 2 08/032 08/051 08/050 Page 08/034 08/044 08/051 08/050 Page 1 Motor-protective circuit-breaker Circuit-breaker 08/032 7 Remote operator 08/044 Additional accessories 08/050 Trip-indicating auxiliary contact and short-circuit indicator 1 Standard auxiliary contacts Notes PKZ2 Motor-Protective Circuit-Breakers Standard Auxiliary Contacts, Trip-Indicating Auxiliary Contacts, Short-Circuit Indicators, Current Limiters +NHI11-PKZ2 093050 Type suffix Article no. When ordered with basic unit PKZ2 Motor-Protective Circuit-Breakers Standard Auxiliary Contacts, Trip-Indicating Auxiliary Contacts, Short-Circuit Indicators, Current Limiters 08/040 08/041 Motor-Protective Circuit-Breakers Motor-Protective Circuit-Breakers Contact sequence 2.14 2.13 2.24 2.23 HI20 L1L2L3 Off/Trip HI20 L1L2L3 On For DC D2 U< D1 2.14 2.13 UVHI L1L2L3 Off/Trip UVHI L1L2L3 Undervoltage releases, Off-delayed Delay time 200 ms With auxiliary contact On For AC D2 U< D1 With auxiliary contact For AC D2 U< D1 Undervoltage releases, non-delayed For AC C2 C1 Shunt releases For AC and DC Circuit diagram PKZ2 Motor-Protective Circuit-Breakers Shunt Releases, Undervoltage Releases 08/042 24 V DC 24 V 50 Hz 24 V 60 Hz 110 V DC 110 V 50 Hz 230 V 50 Hz 110 V 60 Hz 220 V 60 Hz 380 V 50 Hz 440 V 50 Hz 480 V 60 Hz 48 V DC 48 V 50 Hz 48 V 60 Hz 125 V DC 127 V 50 Hz 240 V 50 Hz 120 V 60 Hz 240 V 60 Hz 400 V 50 Hz 500 V 50 Hz 600 V 60 Hz 415 V 50 Hz 208 V 60 Hz 250 V DC 220 V 50 Hz 60 V DC Actuating voltage Voltage and frequency combinations possible with one coil in the voltage release. Moeller HPL0211-2001/2002 +UVHI-PKZ2(230V50HZ) 065764 +U-HI20-PKZ2(230V50HZ) 065762 +U-PKZ2(230V50HZ) 065760 +U-PKZ2(24V DC) 002558 +A-PKZ2-C 063962 +A-PKZ2-B 063965 +A-PKZ2-A 063966 Type suffix Article no. When ordered with basic unit UVHI-PKZ2(230V50HZ) 065770 U-HI20-PKZ2(230V50HZ) 065768 U-PKZ2(230V50HZ) 065766 U-PKZ2(24V DC) 014463 A-PKZ2-C 063930 A-PKZ2-B 063964 A-PKZ2-A 063967 Type Article no. When ordered separately – – – – – – – Price See Price List PKZ2 Motor-Protective Circuit-Breakers Shunt Releases, Undervoltage Releases 1 off 1 off 1 off Std. pack Can be combined with remote operator. Two integral early-make contacts. Voltage dips F 200 ms do not result in disconnection, Contact time on energization: 200 ms. When the circuit-breaker is in the tripped position, the auxiliary contacts are closed. Can be fitted to motor-protective circuit-breaker, circuit-breaker, (high-capacity) compact starter Can be combined with remote operator. Two integral early-make contacts. When combined with circuit-breaker, can be used as Emergency-Stop device to IEC/EN 60 204. When the circuit-breaker is in the tripped position “+” the auxiliary contacts are closed. The undervoltage release can be energized early by means of an additional link (see circuit diagram). This function must not be used in conjunction with RE/RS-PKZ2 (remote operators). Can be fitted to motor-protective circuit-breaker, circuit-breaker, (high-capacity) compact starter When combined with circuit-breaker, can be used as Emergency-Stop device to IEC/EN 60 204 Can be combined with remote operator Can be fitted to motor-protective circuit-breaker, circuit-breaker, (high-capacity) compact starter Can be combined with remote operator. Can be fitted to motor-protective circuit-breaker, circuit-breaker, (high-capacity) compact starter 1 7 Page 08/043 Page 08/034 08/044 08/051 08/050 08/057 7 2 (High-capacity) compact starter 7 Remote operator 9 Clip plate Additional accessories Additional actuating voltages 9 Accessories 2 1 Motor-protective circuit-breaker Circuit-breaker 08/032 7 Remote operator 08/044 Additional accessories 08/050 Accessories Notes Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers Motor-Protective Circuit-Breakers Notes RS-PKZ2 remote operator RE-PKZ2 remote operator T Ι> L T Ι> L A20 A30 A0 72 74 A20 A40 B20 72 74 PKZ2 Motor-Protective Circuit-Breaker Remote Operators 08/044 I OFF A20 O LINE RESET A40 CONTROL 74 N(-) B20 I OFF A20 O B20 34 RESET A40 33 LINE A0 A20 OFF/ RESET 24V DC 34 A0 CONTROL A30 33 74 N(-) 24V DC LINE 72 OFF/ RESET A30 34 L(+) A20 OFF/RESET ON CONTROL CONTROL CONTROL LINE O I O I O I 30 OFF ON ON 15 Main contact 300 Minimum command time for RE-PKZ2, RS-PKZ2 remote operators ON ON 33 CONTROL 74 N(-) LINE 72 L(+) 34 33 CONTROL 74 N(-) OFF equals RESET ON 72 L(+) OFF equals RESET ON 72 L(+) OFF and RESET separate Circuit diagram for pulsed operation 30 OFF/RESET 15 t (ms) t (ms) t (ms) Power and control sections electrically isolated from one another. Control section 24 V as standard. Safe isolation between power and control section is ensured. Can be actuated by a single pulse (f2 VA/W, 15 ms) or by maintained contact. The control section is actuated directly via PLC electronic outputs (24 V DC). Upon actuation the power section is supplied directly from the mains system (700 VA/W, 30 ms). Control section can be actuated by: NHI, AGM, ETS4-VS3, EK..., PLC with potential-free contacts without RC suppressor. Power and control sections have the same potential. Can be actuated by a single pulse (f2 VA/W, 15 ms) or by maintained contact. Upon actuation, the power section is supplied directly from the mains system (700 VA/W, 30 ms). Moeller HPL0211-2001/2002 RS-PKZ2(24V50/60HZ,DC) 063682 RS-PKZ2(220–240V50/60HZ,DC) 063688 RE-PKZ2(24V50/60HZ,DC) 063670 RE-PKZ2(220–240V50/60HZ,DC) 063676 Type Article no. – – – – Price See Price List 1 off 1 off 1 off 1 off Std. pack PKZ2 Motor-Protective Circuit-Breaker Remote Operators Can be fitted to circuit-breaker and (highcapacity) compact starter. Remote On/Off switching of circuit-breaker and trip reset to OFF. Remote operator can be switched off locally and the thumb-grip locked using 6 mm padlock. Suitable for use with AC or DC. Can be combined with U, U-HI20, UVHI-PKZ2 voltage releases or A-PKZ2. NHI standard auxiliary contact is always required in addition for combination of circuit-breaker and RE/RS-PKZ2 remote operator. Cannot be used in conjunction with (R)H-PKZ2 door-coupling handle. Mounting is possible in On and Off switch positions. Internal electronic interlocking always makes “Off” a priority. A green background qto the slide indicates the “Hand” position with contacts (33/34) open. A red background qto the slide indicates the “Auto” position with contacts (33/34) closed. Remote switching is possible. In the “Hand” position, remote switching is not possible. 9 2 (High-capacity) compact starter Additional accessories 4 Standard auxiliary contacts 5 Trip-indicating auxiliary contact 9 Clip plate Other actuating voltages or supply voltages Accessories 5 2 08/034 08/050 08/040 08/040 08/051 08/062 Page 08/032 08/040 08/040 08/050 4 Page 1 Accessories 3 08/045 1 Motor-protective circuit-breaker Circuit-breaker 3 Standard auxiliary contact 5 Trip-indicating auxiliary contact Additional accessories 5 Notes Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers Motor-Protective Circuit-Breakers Moeller HPL0211-2001/2002 T 13 14 A1 A2 T T A2 24V DC 13 23 14 24 A1 13 21 14 22 A1 A2 Base for separate mounting Suppressor circuit Varistor suppressor DC operated A2 A1 T 14 A2 A2 14 24 A1 13 23 A2 14 22 13 T T A1 Ι Ι 24V DC High-capacity contact module with current limiting contacts A1 13 21 AC operated DC operated Contact module AC operated 20 20 20 20 20 20 kW 380 – 415 V 110 – 250 V 24 – 48 V 11 11 11 11 11 11 kW 22 22 22 22 22 22 kW Max. AC-3 motor rating 220 V 380 V 440 V 230 V 400 V 240 V 415 V 24 24 24 24 24 24 kW 500 V 30 30 30 30 30 30 kW 660 V 690 V 1M 2M 1M 1M 2M 1M – – 1B – – 1B Auxiliary contacts M = Make B = Break PKZ2 Motor-Protective Circuit-Breakers Contact Modules, High-Capacity Contact Modules, Suppressors, Base for Separate Mounting 08/046 S(E1A)-...-PKZ2 CL-PKZ2 S(E1A)-...-PKZ2, PKZ2(4) PKZ2(4) PKZ2(4) PKZ2(4) PKZ2(4) PKZ2(4) For use with Moeller HPL0211-2001/2002 EZ-PKZ2 028596 VGSPKZ48 063974 VGSPKZ250 063973 VGSPKZ415 063972 S-G-PKZ2(24VDC) 070921 S/HI20-S-PKZ2(230V50HZ) 063703 S-PKZ2(230V50HZ) 063696 SE1A-G-10-PKZ2(24VDC) 058856 SE1A/20-PKZ2(230V50HZ) 063718 SE1A/11-PKZ2(230V50HZ) 063711 Type Article no. – – – – – – – – – – Price See Price List 1 off 10 off 1 off 1 off Std. pack For retrofitting of (high-capacity) contact module or current limiter, separate mounting With separate contacts also provides fixing base for HI11-S/EZ-PKZ2 auxiliary contacts. Can be snap-fitted on EN 50 022 top-hat rails or secured using M4 screws. For (high-capacity) contact modules with 50–60 Hz AC actuation High-capacity contact module Serial No.01 suitable for mounting with MV-PKZ2. The coil cannot be changed. The HI10-S-PKZ2 integral auxiliary contact is freely configurable. The auxiliary contact cannot be changed. DC operated unit with varistor suppressor. Clip plate for snap-fitting the combination to be ordered separately. Can be fitted to 3- or 4-pole circuitbreaker. With clip plate fitted, can be snap fitted onto one 15 mm or two 10 mm top-hat rails. Can be mounted separately using base (see below), RC suppressor on request. 3 4 1 9 1 Motor-protective circuit-breaker Circuit-breaker 3 Standard auxiliary contact 4 Standard auxiliary contacts 5 Trip-indicating auxiliary contact 6 Shunt releases Undervoltage releases 7 Remote operator 9 Clip plate Additional accessories Additional actuating voltages Accessories 5 Notes PKZ2 Motor-Protective Circuit-Breakers Contact Modules, High-Capacity Contact Modules, Suppressors, Base for Separate Mounting 7 6 08/042 08/044 08/051 08/050 08/063 08/032 08/040 08/040 08/040 Page 08/047 Motor-Protective Circuit-Breakers Motor-Protective Circuit-Breakers L1L2L3 HI L1L2L3 HI Mechanical Interlock Single coil for (high-capacity) contact module 2M 1M 1B Auxiliary contacts for (high-capacity) contact module Off On Auxiliary contacts for (high-capacity) contact module, separate mounting 1M 1B Neutral conductor for (high-capacity) contact module Control circuit terminal Complies with IEC and UL/CSA Auxiliary contacts M = Make B = Break PKZ2 Motor-Protective Circuit-Breakers Accessories for Contact Modules 08/048 8 N 32 31 N-S-PKZ 2 Ι Ι 44 43 2 T1 4 T2 Circuit diagram Ι 6 T3 13 14 A1 A2 22 21 MV-PKZ2 033938 J-S-PKZ2(230V50HZ) 063725 HI11-S-PKZ2 033936 HI20-S-PKZ2 033935 HI11-S/EZ-PKZ-2 090305 N-S-PKZ2 001470 ST-PKZ2 010998 Type Article no. Moeller HPL0211-2001/2002 – 1 off 1 off 1 off – – 1 off 1 off 1 off 3 sets Std. pack – – – – Price See Price List Can be combined with S-PKZ2 high-capacity contact module Serial No. 01. For mechanically interlocking two separately mounted (high-capacity) contact modules or two (high-capacity) compact starters, four end brackets supplied RC suppressor on request Auxiliary contacts to replace integral auxiliary contacts in (high-capacity) contact module. Replacement not possible with SE1A-G-10-PKZ2 contact module or S-G-PKZ2 high-capacity contact module. Can be fitted on side of base for separate mounting Required when a 4-pole circuit-breaker is combined with a 3-pole (high-capacity) contact module; permits fitting and operation of NHI...S-PKZ2 standard auxiliary contacts Enables control circuit supply to be tapped off between motor-protective circuitbreaker and (high-capacity) contact module Fast-on connectors can be fitted (insulated/non-insulated) 2.8 mm Max. cross-section 0.5 – 1 mm2, 20 – 16 AWG Max. current tapped off 1 A or 15 % of set value Increase setting of overload release accordingly. 1 set = 2 off PKZ2 Motor-Protective Circuit-Breakers Accessories for Contact Modules 8 Page 08/046 08/046 08/063 8 (High-capacity) contact module 10 Base for separate mounting Additional actuating voltages 8 Accessories 10 Page 9 08/040 08/046 08/051 1 Accessories 3 3 Standard auxiliary contact 8 (High-capacity) contact module 9 Clip plate Notes Moeller HPL0211-2001/2002 08/049 Motor-Protective Circuit-Breakers 08/050 Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Insulated Enclosures, Accessories For use with Insulated enclosures for surface mounting For motor-protective circuit-breakers, 3- or 4-pole circuit-breakers Degree of protection IP40 PKZ2/ZM-... +NHI Cover with aperture dimensioned to + AGM + U or A accommodate front of breaker, comes or RE or RS with blanking strip PKZ24/ZM-... + NHI + AGM + U or A Degree of protection IP54 PKZ2/ZM-... + NHI For mounting of (R)H-PKZ2 + AGM + U or A door coupling handle + (R)H PKZ24/ZM-... + NHI + AGM + U or A + (R)H For 3-pole compact starters, high-capacity compact starters, combination circuit-breakers (Kombi) Degree of protection IP40 Cover with aperture dimensioned to accommodate front of breaker, comes with blanking strip Degree of protection IP54 For mounting of (R)H-PKZ2 door coupling handle Type Article no. CI19EA-PKZ2 026234 1 off CI19EB-PKZ2 028607 – CI19ED-PKZ24 005145 – Built-in EN 50 022 top-hat rail, separate terminals for PE(N) and N L-PKZ0 indicator lights can be fitted a Page 08/022 PKZ2/ZM-.../S(E1A) + NHI + AGM + RE or RS or U or A CI23EA-PKZ2 087936 – 1 off PKZ2/ZM-.../S + NHI + AGM + U or A + (R)H CI23EB-PKZ2 090309 – 1 off – – 1 off – 1 off – – 1 off H-PKZ2 043218 – 1 off RH-PKZ2 045591 – H-PKZ2-MCC 201427 – RH-PKZ2-MCC 201428 – A-H-PKZ2 047964 – E-PKZ2 003218 PKZ2/ZM-... + NHI + AGM PKZ2/ZM-... + U or A PKZ24/ZM-... E54-PKZ2 033939 For connection of a 5th conductor In E-PKZ2 and E54-PKZ2 N-PKZ2 003219 Neutral terminal Plug-fit extension shaft for door coupling handle Can be extended as required for mounting depths from 171 – 300 mm – – Including cable entries: 2 x PG 16/21/29 Degree of protection IP54 (R)H-PKZ2 door coupling handle also required as standard For use on main switches with Emergency-Stop function to IEC/EN 60 204, Colour red/yellow For use in MCC distribution boards with PKZ2 turned through 90°. For use on main switches to IEC/EN 60 204 For use in MCC distribution boards with PKZ2 turned through 90°. For use on main switches with Emergency-Stop function to IEC/EN 60 204 Std. pack – Insulated enclosures for flush mounting For motor-protective circuit-breakers, 3- or 4-pole circuit-breakers Degree of protection IP41 PKZ2/ZM-... Grey front plate with retaining frame + NHI + AGM PKZ2/ZM-... Integral PE(N) terminal + U or A PKZ24/ZM-... Door coupling handle IP65 For use on main switches to IEC/EN 60204 Colour: black Price See Price List Complete with L3/5-CI23 mounting plate Will accept compact starter or PKZ2/ZM-.../S high-capacity compact starter without clip plate For mounting in side plate or door. Vertical mounting position. L-PKZ0 indicator light can be fitted a Page 08/022 Lockable in 0ff or On position. Suitable for 3 padlocks with 4 – 8 mm hasp thickness Additional front plates: ZFS...-T0 or ZFS...-P3 (a Page 07/054) 17 x 48 mm or 27 x 88 mm and ZFS60-NZM7 (a Page 10/032) 17 x 64 mm can be used 5 off 08/051 Moeller HPL0211-2001/2002 Type Article no. Price See Price List Std. pack C-PKZ2 052710 – 2 off Can be snap fitted to one EN 50 022 top-hat rail, height 15 mm, or two, height f 10 mm Can be used with AD busbar adapter (a Page 08/052) B3.1/3-PKZ2 033940 – 5 off Can be lengthened to take several PKZ2 by rotated mounting. Protection against direct contact, Ue = 690 V, Iu = 120 A For wiring two PKZ2s Space is provided for either one auxiliary contact or one voltage release B3.1/2-PKZ2 063969 – 5 off For three-phase commoning link. Protection against direct contact Ue = 690 V, Iu = 120 A For connecting: max. 1x50 mm² or 2 x35 mm²; one above the other min. 1 x 1 mm² or 2 x1 mm² BK50/3-PKZ2 033941 – 5 off H-B3-PKZ2 063968 – 10 off Three-phase commoning link must have a latching facility SVB-PKZ2 050337 – 5 off Suitable for 3 padlocks; hasp thickness 5 – 8 mm CS-PKZ2 055083 – 1 off For coding the trip block to match the PKZ2(4) basic unit Coding in binary Clip plate For optional snap fitting or M4 screw fixing of circuitbreaker with (high-capacity) contact module or current limiter Three-phase commoning link For wiring three PKZ2s Space is provided for either two auxiliary contacts or two voltage releases Incoming terminal Shroud for unused terminals Protection against direct contact. To cover unused terminals on three-phase commoning link Padlocking feature For locking rear mounting circuit-breakers in the Off position when the panel door is open Coding pins Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Accessories 08/052 Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Accessories Rated operational voltage Ue V Rated operational current Ie A Adapter width 40 Price See Price List Std. pack mm Component adapter, 3-pole For mounting on 20 x 5 mm flat copper busbars and on 800 A rigid copper busbars with 60 mm interval between phase centres 690 40 72 690 Type Article no. 144 For mounting on 30 x10 mm and 20 x 10 mm flat copper busbars 1600 A rigid copper busbars with 60 mm intervals between phase centres 690 40 72 – AD40/5-1 025401 – AD40/5-2 025403 – 1 off Mounted by latching onto de-energized busbar PKZ2/ZM-... circuit-breaker or PKZ2/ZM-.../S(E1A) (high-capacity) compact starter as direct-on-line starter up to 18.5 kW/400 V – AD40/10-1 025402 – 690 40 144 AD40/10-2 025404 – – – 9 AD-E 060511 – 1 off Mounted by latching onto de-energized busbar PKZ2/ZM-... circuit-breaker or PKZ2/ZM-.../S(E1A) (high-capacity) compact starter as direct-on-line starter up to 18.5 kW/400 V Adapter extension 1 off Can be fitted onto AD... to extend mounting width Moeller HPL0211-2001/2002 08/057 Compact starters Contact module with 1 make/1 break auxiliary contact AC PKZ2/ZM-1/ SE1A/11(...) Standard coils 24V 50Hz 48V 50Hz 240V 50Hz 24V 60Hz 110V 50Hz, 120V 60Hz 190V 50Hz, 220V 60Hz 220V 50Hz, 240V 60Hz 230V 50Hz, 240V 60Hz 380V 50Hz, 440V 60Hz 400V 50Hz, 440V 60Hz 415V 50Hz, 480V 60Hz 24V 50/60Hz 110V 50/60Hz 230V 50/60Hz Non-standard coils (i.e. voltages other than the standard voltages listed above)2) ...V 50Hz (24 – 600V) ...V 60Hz (24 – 600V) Notes 1) 2) PKZ2/ZM-1,6/ SE1A/11(...) PKZ2/ZM-2,4/ SE1A/11(...) PKZ2/ZM-4/ SE1A/11(...) PKZ2/ZM-6/ SE1A/11(...) Article no. 1) See Price List Article no. 1) See Price List Article no. 1) See Price List Article no.1) See Price List Article no. 1) See Price List 058902 058904 058909 058903 063362 058922 058924 058929 058923 063370 058942 058944 058949 058943 063380 058962 058964 058969 058963 063390 058982 058984 058989 058983 063400 063363 063371 063381 063391 063401 063367 063375 063385 063395 063405 063364 063372 063382 063392 063402 063368 063376 063386 063396 063406 063365 063373 063383 063393 063403 063366 063374 063384 063394 063404 063585 063586 063369 See Price List 063377 063378 063379 See Price List 063387 063388 063389 See Price List 063397 063398 063399 See Price List 063407 063408 063409 See Price List 907517 907518 908149 908150 908151 908152 907523 907524 908153 908154 To obtain the article number for ordering, read under selected type and actuating voltage from the table above. Units with dual-voltage coils must be ordered using one article number. When ordering non-standard coils please state the required actuating voltage from the given range (...–...V). Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Actuating Voltages 08/058 Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Actuating Voltages Compact starters Contact module with 1 make/1 break auxiliary contact AC PKZ2/ZM-10/ SE1A/11(...) Standard coils 24V 50Hz 48V 50Hz 240V 50Hz 24V 60Hz 110V 50Hz, 120V 60Hz 190V 50Hz, 220V 60Hz 220V 50Hz, 240V 60Hz 230V 50Hz, 240V 60Hz 380V 50Hz, 440V 60Hz 400V 50Hz, 440V 60Hz 415V 50Hz, 480V 60Hz 24V 50/60Hz 110V 50/60Hz 230V 50/60Hz Non-standard coils (i.e. voltages other than the standard voltages listed above)2) ...V 50Hz (24 – 600V) ...V 60Hz (24 – 600V) Notes 1) 2) PKZ2/ZM-16/ SE1A/11(...) PKZ2/ZM-25/ SE1A/11(...) PKZ2/ZM-32/ SE1A/11(...) PKZ2/ZM-40/ SE1A/11(...) PKZ2/ SE1A/11(...) Article no. 1) See Price List Article no. 1) See Price List Article no. 1) See Price List Article no.1) See Price List Article no. 1) See Price List Article no.1) See Price List 059002 059004 059009 059003 063410 059022 059024 059029 059023 063420 059042 059044 059049 059043 063430 059062 059064 059070 059063 063440 059082 059084 059089 059083 063450 082063 082064 082137 082138 082139 063411 063421 063431 063441 063451 082140 063415 063425 063435 063445 063455 082141 063412 063422 063432 063442 063452 082142 063416 063426 063436 063446 063456 082143 063413 063423 063433 063443 063453 082144 063414 063424 063434 063444 063454 082145 063417 063418 063419 See Price List 063427 063428 063429 See Price List 063437 063438 063439 See Price List 063447 063448 063449 See Price List 063457 063458 063459 See Price List 082146 082147 082148 See Price List 907505 907506 907507 907508 907509 907510 907511 907512 907513 907514 982149 982150 To obtain the article number for ordering, read under selected type and actuating voltage from the table above. Units with dual-voltage coils must be ordered using one article number. When ordering non-standard coils please state the required actuating voltage from the given range (...–...V). 08/059 Moeller HPL0211-2001/2002 High-capacity compact starters Contact module with 1 make/1 break auxiliary contact AC PKZ2/ZM-1/ S(...) Standard coils 24V 50Hz 48V 50Hz 240V 50Hz 24V 60Hz 110V 50Hz, 120V 60Hz 190V 50Hz, 220V 60Hz 220V 50Hz, 240V 60Hz 230V 50Hz, 240V 60Hz 380V 50Hz, 440V 60Hz 400V 50Hz, 440V 60Hz 415V 50Hz, 480V 60Hz 24V 50/60Hz 110V 50/60Hz 230V 50/60Hz Non-standard coils (i.e. voltages other than the standard voltages listed above)2) ...V 50Hz (24 – 600V) ...V 60Hz (24 – 600V) Notes 1) 2) PKZ2/ZM-1,6/ S(...) PKZ2/ZM-2,4/ S(...) PKZ2/ZM-4/ S(...) PKZ2/ZM-6/ S(...) Article no.1) See Price List Article no. 1) See Price List Article no. 1) See Price List Article no.1) See Price List Article no. 1) See Price List 028981 059117 031402 059116 063470 000505 059110 031534 059109 063480 052711 059138 031616 059137 063490 076441 059159 031770 059158 063500 097798 059173 026869 059172 063510 063471 063481 063491 063501 063511 063475 063485 063495 063505 063515 063472 063482 063492 063502 063512 063476 063486 063496 063506 063516 063473 063483 063493 063503 063513 063474 063484 063494 063504 063514 063477 063478 063479 See Price List 063487 063488 063489 See Price List 063497 063498 063499 See Price List 063507 063508 063509 See Price List 063517 063518 063519 See Price List 907495 907496 907497 907498 907499 907500 907501 907502 907503 907504 To obtain the article number for ordering, read under selected type and actuating voltage from the table above. Units with dual-voltage coils must be ordered using one article number. When ordering non-standard coils please state the required actuating voltage from the given range (...–...V). Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Actuating Voltages 08/060 Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Actuating Voltages High-capacity compact starters Contact module with 1 make/1 break auxiliary contact AC PKZ2/ZM-10/ S(...) Standard coils 24V 50Hz 48V 50Hz 240V 50Hz 24V 60Hz 110V 50Hz, 120V 60Hz 190V 50Hz, 220V 60Hz 220V 50Hz, 240V 60Hz 230V 50Hz, 240V 60Hz 380V 50Hz, 440V 60Hz 400V 50Hz, 440V 60Hz 415V 50Hz, 480V 60Hz 24V 50/60Hz 110V 50/60Hz 230V 50/60Hz Non-standard coils (i.e. voltages other than the standard voltages listed above)2) ...V 50Hz (24 – 600V) ...V 60Hz (24 – 600V) Notes 1) 2) PKZ2/ZM-16/ S(...) PKZ2/ZM-25/ S(...) PKZ2/ZM-32/ S(...) PKZ2/ZM-40/ S(...) PKZ2/S(...) Article no. 1) See Price List Article no. 1) See Price List Article no. 1) See Price List Article no.1) See Price List Article no. 1) See Price List Article no.1) See Price List 095146 059124 027021 059123 063520 076165 059131 027125 059130 063530 073793 059145 027519 059144 063540 076167 059152 028717 059151 063550 002607 059166 029051 059165 063560 063580 063581 063582 063583 063570 063521 063531 063541 063551 063561 063571 063525 063535 063545 063555 063565 063575 063522 063532 063542 063552 063562 063572 063526 063536 063546 063556 063566 063576 063523 063533 063543 063553 063563 063573 063524 063534 063544 063554 063564 063574 063527 063528 063529 See Price List 063537 063538 063539 See Price List 063547 063548 063549 See Price List 063557 063558 063559 See Price List 063567 063568 063569 See Price List 063577 063578 063579 See Price List 907491 907492 907489 907490 907487 907488 907485 907486 907483 907484 907481 907482 To obtain the article number for ordering, read under selected type and actuating voltage from the table above. Units with dual-voltage coils must be ordered using one article number. When ordering non-standard coils please state the required actuating voltage from the given range (...–...V). 08/061 Moeller HPL0211-2001/2002 Undervoltage releases AC When ordered with basic unit +U-PKZ2(...) +U-HI20-PKZ2(...) +UVHI-PKZ2(...) When ordered separately U-PKZ2(...) U-HI20-PKZ2(...) UVHI-PKZ2(...) Standard coils Article no.1) See Price List Article no.1) See Price List Article no.1) See Price List Article no.1) See Price List Article no. 1) See Price List Article no.1) See Price List 062204 012050 099850 063611 063612 063621 063622 063623 063625 063626 071321 012083 066661 063636 063637 055085 023955 009717 063632 065686 063649 063650 063652 063654 063655 073694 000226 090399 063663 063664 063613 063627 063638 065685 063656 063665 065760 065762 065764 065766 065768 065770 063614 063628 063639 065689 063657 063666 065761 065763 065765 065767 065769 065771 063615 063629 063640 065684 063658 063667 063616 063617 See Price List 063630 063631 See Price List 063641 063642 See Price List 063646 063647 See Price List 063659 063660 See Price List 063668 063669 See Price List 908155 908156 907531 907532 907533 907534 908157 908158 907537 907538 907539 907540 DC Standard coils See Price List See Price List – See Price List – See Price List See Price List – See Price List – 24V DC 48V DC 60V DC 110/125V DC 002558 059510 050059 063620 – – – – – – – – 014463 028701 035820 063648 – – – – – – – – 24V 50Hz 48V 50Hz 240V 50Hz 208/220V 60Hz 110V 50Hz, 120V 60Hz 220V 50Hz, 240V 60Hz 230V 50Hz, 240V 60Hz 380V 50Hz, 440V 60Hz 400V 50Hz, 440V 60Hz 415V 50Hz, 480V 60Hz 24V 50/60Hz 48V 50/60Hz Non-standard coils (i.e. voltages other than the standard voltages listed above)2) ...V 50Hz (24 – 600V) ...V 60Hz (24 – 600V) Notes 1) 2) To obtain the article number for ordering, read under selected type and actuating voltage from the table above. Units with dual-voltage coils must be ordered using one article number. When ordering non-standard coils please state the required actuating voltage from the given range (...–...V). Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Actuating Voltages 08/062 Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Actuating Voltages Remote operators AC, DC RE-PKZ2(...) RS-PKZ2(...) Standard coils Article no.1) See Price List Article no. 1) See Price List 063670 063671 063672 063673 063674 063675 063676 See Price List 063682 063683 063684 063685 063686 063687 063688 See Price List 063679 063680 063681 063691 028912 063693 AC Standard coils See Price List See Price List 380 – 415V 50/60Hz Non-standard coils 063677 See Price List 063689 See Price List 063678 063690 24V 50/60Hz, DC 42V 50/60Hz, DC 48V 50/60Hz, DC 110 – 120V 50/60Hz, DC 120 – 130V 50/60Hz, DC 190 – 220V 50/60Hz, DC 220 – 240V 50/60Hz, DC Non-standard voltages (i.e. voltages other than the standard voltages listed above); please state the desired actuating voltage 60V 50/60Hz, DC 110V 50/60Hz, DC 170 – 190V 50/60Hz, DC 440V 50/60Hz Notes 1) To obtain the article number for ordering, read under selected type and actuating voltage from the table above. 08/063 Moeller HPL0211-2001/2002 (High-capacity) contact module Separate coil for (high-capacity) contact module AC S-PKZ2(...) S/HI20-S-PKZ2(...) SE1A/11-PKZ2(...) SE1A/20-PKZ2(...) Standard coils Article no.1) See Price List Article no. 1) See Price List Article no.1) See Price List Article no.1) See Price List J-S-PKZ2(...) Separate coils Article no.1) See Price List 24V 50Hz 48V 50Hz 240V 50Hz 24V 60Hz 110V 50Hz, 120V 60Hz 190V 50Hz, 220V 60Hz 220V 50Hz, 240V 60Hz 230V 50Hz, 240V 60Hz 380V 50Hz, 440V 60Hz 400V 50Hz, 440V 60Hz 415V 50Hz, 480V 60Hz 24V 50/60Hz 110V 50/60Hz 230V 50/60Hz Non-standard coils (i.e. voltages other than the standard voltages listed above)2) ...V 50Hz (24 – 600V) ...V 60Hz (24 – 600V) 026609 062651 001882 062501 063694 056378 056383 057048 056380 063701 058722 058742 058716 058724 063709 058723 058743 058717 058725 063716 035726 065114 065126 065111 063723 063695 063702 063710 063717 063724 063699 063706 063714 063721 063728 063696 063703 063711 063718 063725 063700 063707 063715 063722 063729 063697 063704 063712 063719 063726 063698 063705 063713 063720 063727 062500 063063 065103 See Price List 056379 056385 056395 See Price List 058720 058696 058712 See Price List 058721 058697 058713 See Price List 065110 065116 065125 See Price List 907541 907542 907543 907544 907545 907546 907547 907548 907549 907550 DC S-G-PKZ2(...) SE1A-G-10-PKZ2(...) Standard coils Article no.1) See Price List Article no. 1) See Price List 24V DC 110V DC 125V DC 070921 218934 203583 058856 218935 203582 Notes 1) 2) To obtain the article number for ordering, read under selected type and actuating voltage from the table above. Units with dual-voltage coils must be ordered using one article number. When ordering non-standard coils please state the required actuating voltage from the given range (...–...V). Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Actuating Voltages 08/072 Moeller HPL0211-2001/2002 S-PKZ2 high-capacity contact module, SE1A-PKZ2 contact module Normal switching duty Squirrel-cage motors Operating characteristics: Typical applications: AC-3/400V 0.55 0.37 0.25 A Rated operational current 50...60 Hz Rated output of three-phase motors 50...60 Hz kW 18.5 15 11 7.5 5.5 4 3 2.2 1.5 1.1 0.75 35 28.5 22.1 15.4 11.4 8.8 6.8 5.2 3.6 2.65 1.86 S(E1A)-PKZ2 Electrical characteristics: from rest after attaining full running speed Lifts Mixers Escalators Agitators Conveyors Centrifuges Bucket-elevators Airconditioning systems Drives in general for manufacturing and processing machines Starting: up to 6 X motor rated current Stopping: 1 X motor rated current Utilization category: 100 % AC-3 Normal switching duty 1.42 1.05 0.81 0.1 0.2 0.4 0.6 0.8 1 2 3 4 5 6 8 10 Component lifespan (millions of operations) Starting: Stopping: Compressors Pumps Fans Valves Extreme switching duty AC-4/400V 0.55 0.37 0.25 35 28.5 22.1 15.4 11.4 8.8 6.8 5.2 3.6 2.65 1.86 A Rated operational current 50...60 Hz Rated output of three-phase motors 50...60 Hz kW 18.5 15 11 7.5 5.5 4 3 2.2 1.5 1.1 0.75 S(E1A)-PKZ2 Squirrel-cage motors Operating characteristics: Typical applications: Electrical characteristics: Extreme switching duty 1.42 1.05 0.81 0.01 0.02 0.03 0.04 0.06 0.2 0.3 0.4 0.6 1 2 3 45 Component lifespan (millions of operations) 0.1 Utilization category: Inching, plugging, reversing Printing machines Wire-drawing machines Centrifuges Special drives for manufacturing and processing machines Starting: Stopping: 6 X motor rated current 6 X motor rated current 100 % AC-4 Light switching duty Non-motor loads Operating characteristics: Typical applications: Electrical characteristics: AC-1/400V A Breaking current Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics 40 35 28,5 22,1 15,4 11,4 8,8 6,8 5,2 3,6 2,65 1,86 S(E1A)-PKZ2 Utilization category: Non-inductive or slightly inductive load Electric heat Starting: Stopping: up to 1.5 X rated current 1 X rated current 100 % AC-1 Non-motor loads, 3-pole 1,42 1,05 0,81 0,1 0,2 0,4 0,6 0,8 1 2 3 4 5 6 8 10 Component lifespan (millions of operations) Determination of the maximum number of operations per hour for (high-capacity) contact modules dependent on the switching capacity and utilization PN = Maximum motor rating (kW) Ops./h = Maximum operating frequency per hour Ops./h 9000 7000 6000 5000 4000 3000 AC-3 2000 1500 1000 800 AC-4 600 500 400 300 200 150 100 0 10 20 30 40 50 60 70 80 90 100% PN (kW) 08/073 Moeller HPL0211-2001/2002 Tripping characteristics of motor-protective circuit-breakers, (high-capacity) compact starters 2h 20 2h 20 5 2 1 40 1 40 20 20 10 5 10 5 2 2 1 1 200 200 Milliseconds Milliseconds 5 Seconds Seconds 2 PKZ2/ZM-...-8 10 Minutes PKZ2/ZM-... PKZ2/ZM-.../S PKZ2/ZM-.../SE1A 10 Minutes Tripping characteristics for cable and conductor protection 50 20 50 20 5 5 2 1,5 2 3 4 6 8 10 x Rated operational current 15 20 2 30 1,5 2 3 4 6 8 10 x Rated operational current 15 20 30 Let-through characteristics of circuit-breakers, compact starters ∫ 100 PKZ2/ZM-...(-8) 80 PKZ2/ZM-...(-8)/SE1A 2 dt 106 8 PKZ 2/ZM-...(-8) PKZ 2/ZM-...(-8)/SE1A 2 [A s] 6 60 f-w a ve ÎD [kA] 1 st h al 4 40 3 30 2 c ·I c 32/40 A 2 25 A 1.5 20 15 32/40 A 25 A 10 16 A 8 16 A 6 10 A 4 10 A 6 105 8 3 4 6A 2 6A 3 1.5 104 8 2 1.5 U e = 400 V 1 1 1.5 2 3 4 6 8 10 15 20 30 40 e 6 = 400 V 4 60 80 100 1 1.5 2 3 4 6 8 10 15 20 30 40 I cc rms [kA] 60 80 100 ccrms [kA] Let-through characteristics of high-capacity compact starters and circuit-breakers + CL current limiter 2 PKZ2/ZM-...(-8)/S PKZ2/ZM-...(-8)/S-G PKZ2/ZM-...(-8)+CL PKZ2/ZM-.../S-SP 60 6 dt 10 8 PKZ 2/ZM-...(-8)/S PKZ 2/ZM-...(-8)/S-G PKZ 2/ZM-...(-8)+CL PKZ 2/ZM-.../S-SP 2 [A s] f-w ave 80 6 hal 100 4 40 1 st ÎD [kA] 3 30 2· 20 I cc 2 1,5 15 32/40 A 25 A 10 16 A 8 10 A 6 40 A 32 A 25 A 10 5 8 16 A 6 4 3 10 A 2 6A 4 3 6A 2 1.5 10 4 8 1.5 U e = 400 V 1 1 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100 I cc rms [kA] e 6 = 400 V 4 1 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100 ccrms [kA] Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics 08/074 Moeller HPL0211-2001/2002 General technical data Standards Climatic proofing Storage Open Enclosed Min./Max. Min./Max. Min./Max. °C °C °C Mounting position PKZ2/.../S 90 ° PKZ2 PKZ2/.../S PKZ2/.../+CL 30° 90 ° Ambient temperature IEC/EN 60 947, VDE 0660, UL 508, CSA C 22.2 No. 14 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Damp heat, constant, to IEC 60 068-2-3 Damp heat, cyclical, to IEC 60 068-2-30 −25/+70 −25/+60 −25/+40 ° 90 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Technical Data 90° S CL Direction of incoming supply Degree of protection Shock resistance (half-sinusoidal shock 20 ms) to IEC 60 068-2-27 Altitude Terminal capacity Solid or stranded Flexible with ferrule Solid or stranded Specified tightening torque for terminal screws Main cable Control circuit cable Main contacts Rated impulse withstand voltage Uimp Overvoltage category/pollution degree Rated operational voltage Ue Rated uninterrupted current Iu = rated operational current le Rated frequency Current heat losses 3-pole, at operational temperature Lifespan Mechanical Electrical AC-3 DC-5 DC application Rated short-circuit breaking capacity Icn (250 V DC) L/R = 15 ms (125 V DC) Operating times under short-circuit conditions Minimum command time Opening delay Total opening time Trip blocks Temperature compensation IEC/EN 60 947-4-1 Operating range Temperature compensation residual error Short-circuit release tolerance ZM-..-PKZ2, ZMR-..-PKZ2 trip blocks for motor protection Adjustable overload releases Adjustable short-circuit releases Phase-failure sensitivity ZM-..-8-PKZ2 trip blocks for distribution circuit protection Adjustable overload releases Adjustable short-circuit releases g m mm2 mm2 AWG 1 X (1 – 16) or 2 X (1 – 6) 1 X (1.5 – 10) or 2 X (1.5 – 6) 14 – 6 Nm Nm 1.8 1.0 V 6000 III/3 690 40 50 – 60 Circuit-breaker: 14 Circuit-breaker: 0.1X106 (High-capacity) compact starter: 8 (High-capacity) compact starter: 23 (High-capacity) contact module: 5X106 (The mechanical lifespan is reduced by 30% for a dual-frequency coil 50/60Hz) (High-capacity) contact module: 1X106 (High-capacity) contact module: 0.03X106 (High-capacity) contact module: Tripping characteristics a Page 08/072 Ops. Ops. Ops/h Circuit-breaker: 0.05X106 V AC V DC A DC 690 250 40 PKZ2/ZM-..(-8) PKZ2/ZM-..(-8)/S(+CL) kA kA 30 50 50 65 Approx. Approx. Approx. ms ms ms 2 Approx. 0.5 6 2 Approx. 0.5 4 Min./Max. Min./Max. °C °C %/K % −5/+40 −25/+60 0.25 g20 X Iu X Iu 0.6 – 1.0 8.5 – 14 IEC/EN 60 947-4-1 X Iu X Iu 0.6 – 1.0 5 – 8.5 100 % AC-3 AC-4 Maximum operating frequency Motor switching capacity 90° S CL As required IP20 Circuit-breaker: 30 2000 V AC A Hz W Ops. { PKZ2 PKZ2/.../+CL PKZ2 Max. Max. Max. Circuit-breaker: 60 08/075 Moeller HPL0211-2001/2002 Switching capacity of motor-protective circuit-breakers and (high-capacity) compact starters Rated uninterrupted current Iu Rated conditional short-circuit current Iq IEC/EN 60 947-4-1 Rated ultimate short-circuit breaking capacity Icu IEC/EN 60 947-2 Rated service short-circuit breaking capacity Ics Iu A 230 V Iq Icu kA kA 1) Ics kA A 400 V Iq Icu kA kA 1) Ics kA A 30 30 7.5 7.5 7.5 N N N N N N 160 160 160 30 30 7.5 7.5 7.5 N N N N N N N N N N N N N N N N N N N N N N N N 160 160 160 440 V Iq Icu kA kA 1) Ics kA A 5 5 5 5 5 N N N N 80 100 125 160 160 5 5 5 5 5 N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 80 100 125 160 160 N N N N N N N N 500 V Iq Icu kA kA 1) Ics kA A 3.5 3.5 3.5 3.5 3.5 N N N N 80 100 125 160 160 3.5 3.5 3.5 3.5 3.5 N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 80 100 125 160 160 N N N N N N N N 690 V Iq Icu kA kA 1) Ics kA A 2.5 2.5 2.5 2.5 2.5 2.5 2.5 N N 63 80 80 100 125 160 160 PKZ2/ZM with Type “1” and Type “2” coordination 0.16 – 1.6 2.4 4 6 10 16 25 32 40 30 30 30 30 30 30 30 30 7.5 7.5 7.5 N N N N N N 160 160 160 30 30 30 30 30 30 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 PKZ2/ZM + CL-PKZ2 with Type “1” and Type “2” coordination 0.16 – 1.6 2.4 4 6 10 16 25 32 40 30 30 7.5 7.5 7.5 N N N N N N N N N 10 10 10 10 10 10 10 4.5 4.5 4.5 4.5 4.5 4.5 4.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 N N N N N N N N N 4.5 4.5 4.5 4.5 4.5 4.5 4.5 N N N N N N N N N N N N N N N N N N N N 63 80 80 100 125 160 160 10 10 10 N N N N N N N N 80 100 160 PKZ2/ZM(R)-.../SE1A(-G)... with Type “1” coordination 0.16 – 1.6 2.4 4 6 10 16 25 32 40 30 30 30 N N N N N N N N N N N N N N N N N N N N N N N N 160 160 160 30 30 30 N N N N N N N N N 10 10 10 10 10 7 7 7 7 7 PKZ2/ZM-.../S(-G) with Type “1” and Type “2” coordination 0.6 – 2.4 4–6 10 – 16 25 – 40 N N N N N N N N N N N N N N N N PKZ2/ZM-..-8 and PKZ2/ZM-..-8/SE1A(-G) 0.16 – 1.6 2.4 4 6 10 16 25 32 40 N N N N N N N N N 30 30 30 30 30 7.5 7.5 7.5 N N N N N N 160 160 160 N N N N N N N N N N N N N N N N N 30 30 30 30 30 7.5 7.5 7.5 N N N N N N 160 160 160 N N N N N N N N N N N N N N N N N 10 10 10 10 10 5 5 5 5 5 N N N N 80 100 125 160 160 N N N N N N N N N N N N N N N N N 7 7 7 7 7 3.5 3.5 3.5 3.5 3.5 N N N N 80 100 125 160 160 N N N N N N N N N 4.5 4.5 4.5 4.5 4.5 4.5 4.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 N N 63 80 80 100 125 160 160 N N N N N N N N 10 10 10 5 5 5 N 80 100 160 PKZ2/ZM-...-8/S(-G) 0.6 – 2.4 4–6 10 – 16 25 – 40 N N N N Notes N No upstream protective device required. Inherently short-circuit-proof range (100kA) Not required 1) Fuse (A gG/gL) increases the switching capacity of the motor-protective circuit-breaker to 100 kA Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Technical Data 08/076 Moeller HPL0211-2001/2002 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Technical Data (High-capacity) contact module Operating times Closing delay Opening delay Duty factor Rated making capacity y = 0.45 Rated breaking capacity cos ϕ = 0.45 Magnet systems AC operation (S-PKZ2, SE-1A-PKZ2) Operating range Pick-up Drop-out Power consumption Pick-up Sealing DC operation (S-G-PKZ2, SE1A-G-10-PKZ2) Rated control supply voltage Us Operating range Pick-up Power consumption Pick-up Pick-up Sealing Sealing Rated operational current Ie 50 – 60 Hz AC voltage open, enclosed 230 V AC 400 V AC 440 V AC 500 V AC 690 V AC Auxiliary contacts Rated impulse withstand voltage Uimp Overvoltage category/pollution degree Rated operational voltage Ue Rated operational current Ie AC-15 NHI11, NHI11S, NHI2-11S, HI11S/EZ NHI22, NHI22S, HI11S, HI20-S AGM2-11 ZMR-... 95 – 96 ZMR-... 97 – 98 DC-13 ZMR-... L/R F200 ms Lifespan Mechanical NHI, NHI..S AGM NHI2-11S, HI..-S, HI11-S/EZ ZMR Electrical NHI, NHI..S AGM NHI2-11S, HI..-S, HI11-S/EZ ZMR Control circuit reliability at Ue = 24 V DC Fault probability HF Umin = 24 V, Imin = 10 mA Interlocked opposing contacts to ZH 1/457 Short-circuit rating without welding Fuseless Fuse Terminal capacity 1 conductor or 2 conductors Solid and flexible with ferrule Solid and stranded ms ms % DF A A 9 – 30 4 – 12 100 400 400 x Us x Us VA VA 0.85 – 1.1 0.4 – 0.6 F 190 F 13 V DC 24 x Us 0.85 – 1.1 VA A W mA 150 6.3 (16 – 22 ms) 2.7 113 AC-3 AC-4 AC-1 A A A A A 40 40 40 40 40 30 30 30 28 25 40 40 40 40 40 V 6000 III/3 500 400/415 V 3 1.5 3 0.7 Approx. 0.5 60 V 0.8 440/500 V 1.5 1.5 1.5 Approx. 0.5 0.3 110 V 220 V 0.7 0.3 V AC A A A A A A Ops. Ops. Ops. Ops. Ops. Ops. Ops. Ops. 230/240 V 6 6 5 1.5 1.5 24 V 1 0.1 x 106 0.01 x 106 5 x 106 0.01 x 106 0.05 x 106 5 x 103 1 x 106 5 x 106 Fail-safe over the entire mechanical lifespan NHI2-11 S, AGM2-11 A gG/gL With PKZM0 – 6,3: 240 V PKZM0 – 4: 415 V PKZM0 – 1,6: 500 V 10 mm2 AWG 0.75 – 2.5 22 – 14 08/077 Moeller HPL0211-2001/2002 Voltage releases Rated impulse withstand voltage Uimp Overvoltage category/pollution degree Rated operational voltage Ue Terminal capacity 1 conductor or 2 conductors Solid and flexible with ferrule Solid and stranded Shunt releases Operating range AC DC Power consumption AC Pick-up Sealing DC Pick-up Sealing Undervoltage releases Drop-out voltage Power consumption AC Pick-up Sealing DC Pick-up Sealing Drop-out delay with UVHI-PKZ2 Rated operational current Ie AC-15 U-HI20-PKZ2, UVHI-PKZ2 RE-PKZ2, RS-PKZ2 remote operators Rated impulse withstand voltage Uimp Overvoltage category/pollution degree Rated operational voltage Ue AC (50/60 Hz), DC AC (50/60 Hz) Safe isolation To VDE 0106 Part 101 and Part 101 A1 between auxiliary contacts and main contacts Required short-time rating (30 ms) Control transformer short-time rating Short-circuit voltage Closing delay Opening delay Reset time to Off Operating frequency Operating range AC DC Lifespan, electrical Integral auxiliary contacts (make contact 33/34 Hand/Auto indication) Conventional free air thermal current Ith Rated operational current Ie AC-14 Terminal capacity 1 conductor or 2 conductors Solid and flexible with ferrule Solid and stranded V V AC V DC 6000 III/3 24 – 600 A-PKZ2: 24 – 250, U-PKZ2: 24 – 125 mm2 AWG 0.75 – 2.5 22 – 14 x Us x Us 0.7 – 1.1 0.7 – 1.1 VA VA W W 5 3 3 0.3 x Us 0.7 – 0.35 VA VA W W ms 5 3 3 3 200 A 230 V 6 400 V 3 V 6000 III/3 V V 24 – 240 380 – 440 V AC 500 VA/W VA % ms ms ms Ops/h 700 1100 a STI0,4 Page 13/006 4.4 a Page 13/038 30 30 30 60 x Us x Us Ops. 0.85 – 1.1 0.85 – 1 50 000 A 1.5 50 Hz A 230/240 V 1.5 mm2 AWG 0.75 – 2.5 22 – 14 400/415 V 1 440 V 1.5 440 V Approx. 0.5 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Technical Data 08/078 Moeller HPL0211-2001/2002 Current limiters Rated making capacity y = 0.45 Rated breaking capacity cos ϕ = 0.45 AC-1 duty Conventional free air thermal current Ith = Ie open, enclosed Feeder terminal and three-phase commoning links Rated impulse withstand voltage Uimp Overvoltage category/pollution degree Rated operational voltage Ue Rated uninterrupted current Iu A A 400 400 A 40 V 6000 III/3 690 120 V AC A Protection for EEx e motors PKZ2 tripping characteristics The tripping characteristics show the tripping time of the circuit-breakers as a function of the response current. They show mean values of the tolerance ranges at an ambient temperature of 20 °C, starting from cold. The tripping time of the bimetallic releases at operational temperature is reduced to approximately 25 % of the values shown. Specific tripping characteristics for each individual setting range are available on request. These tripping characteristics, in 55 x 75 format, self-adhesive, correspond to the data in the PTB Certificates and can be used both for correct selection of motor-protective circuit-breakers for protection of EEx e motors and for documentation on site (2-phase characteristic between 3 and 8 times rated current to VDE 0165). Minutes 2h 20 10 5 PTB Certificate No. 3.53/388.299 Tripping characteristics on 3-phase 2-phase 13 1 40 Secondes Tripping characteristic to AWA No. 128-881-1 128-881-2 128-881-3 128-881-4 128-881-5 128-881-6 128-881-7 128-881-8 128-881-9 128-881-10 128-881-11 Setting range A 0.4 – 0.6 0.6 – 1.0 1.0 – 1.6 1.6 – 2.4 2.4 – 4.0 4.0 – 6.0 6.0 – 10 10 – 16 16 – 25 25 – 32 32 – 40 Circuit diagram For PKZ2/ZMR-... and PKZ2/ZMR-.../S PKZ2/ZM(R)-... PKZ2/ZM(R)-.../S 2 I 20 10 ZMRPosition Hand Auto 5 2 I> 1 K1 14 0 97 95 98 96 K1 200 Milliseconds Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Technical Data “Overload“ 50 K1 20 M 3~ 5 2 1.5 2 3 4 6 8 10 x Rated operational current 15 20 30 ZMR-..-PKZ2 trip block: In EEx e application the break contact 95–96 of the overload relay function must always be used to de-energize the (high-capacity) contact module or contactor. 08/079 Moeller HPL0211-2001/2002 PKZ2 Motor-Protective Circuit-Breakers Technical Data 1 Ι> 3 Ι> 2 5 1 Ι> 4 3 Ι> Ι> 2 6 Motor-Protective Circuit-Breakers Selectivity table 400 V AC See a Page 10/084 1 and 2-pole circuits for PKZM0, PKZM4, PKZ2 devices used for AC and DC switching 5 Ι> 4 6 Protection of PVC insulated cables against thermal overload in fault conditions The table shows which minimum cable cross-sections are protected PKZ(M) motor-protective circuit-breakers up to their conditional rated short-circuit current Iq. For cross-sections protected by PKZM4, please enquire. Minimum protected cross-section 380 – 415 V, 50 Hz, Cu mm 2 4 2.5 1.5 1 Device Type 0.75 ... PKZM0-0,16 PKZM0-6,3 PKZM0-10 PKZM0-16 PKZM0-20 PKZM0-25 ... PKZ2/ZM-0,6 PKZ2/ZM-2,4 PKZ2/ZM-4 PKZ2/ZM-6 PKZ2/ZM-10 PKZ2/ZM-16 PKZ2/ZM-25 PKZ2/ZM-32 PKZ2/ZM-40 Fuseless installation with PKZ(M), back-up protection diagrams 100 ccrms [kA] Inherently short-circuit proof cn PKZM 0 cc Rated short-circuit breaking capacity range 50 PKZ2 at 415 V AC Back-up protection range with CL-PKZ2 or S-PKZ2 30 20 16 Rated shortcircuit breaking capacity range PKZM0-.. 10 6 0.16... Rated current 10 16 20 25 I n[A] PKZ2/ZM Inherently short-circuit proof I cc rms [kA] 415 VAC Back-up protection range with CL-PKZ 0 PKZM0-.. + CL-PKZ0 PKZM0 Inherently short-circuit-proof Icn Icc PKZM 0 100 PKZ2/ZM-.../S PKZ2/ZM-...+CL PKZ2 Inherently short-circuit-proof 50 30 PKZ2/ZM-... 20 10 6 4 0.6... ...16 25 32 40 Rated current I n [A] 08/088 Moeller HPL0211-2001/2002 Circuit-breakers, trip blocks Trip-indicating auxiliary contacts PKZ2/(Z)M-…, ZMR-…-PKZ2 AGM 2-11-PKZ2 19 M4 133.5 109 9 4.5 39.5 62 45 45 68 83 ZMR I> 20 105 105 + 0 68 6 18 AGM 31,5 15 19 38 62.5 71.5 Circuit-breakers Standard auxiliary contacts PKZ24/(Z)M-… NHI…PKZ2 81,5 28,5 109 44,5 105 45 68 6 68 19 105 67 118 133,5 18 18 NHI 22 NHI 11 Voltage releases RE-PKZ2 (…) RS-PKZ2 (…) U-PKZ2 (…) A-PKZ2-… 72 74 RE H A N D A U T O NO 34 33 34 Control 24V only Control A20 A40 36 H A N D A U T O NO 33 74 RS 105 72 44 77 Remote operators 105 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Dimensions A20 B20 45 A30 36 109 126 A0 18 44 109 113 Moeller HPL0211-2001/2002 08/089 (High-capacity) compact starters PKZ2/ZM-.../S(-SP) PKZ2/ZM-.../SE1A... PKZ2/ZM-.../S-G 8.5 71.5 19 109 11 M4 + 6 83 0 I> 11 125 204 190 168 204 15 6.1 S-G (Varistor) S-G (Varistor) 25 18.5 27 46.4 38 62.5 111.4 135.9 Standard auxiliary contacts for (high-capacity) compact starters 18 18 18 NHI 22S NHI 2-11S NHI 11S 153 190 NHI...S-PKZ2 44 77 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Dimensions 08/090 Moeller HPL0211-2001/2002 SE1A(-G) contact module S(-G) high-capacity contact module CL current limiter EZ base for separate mounting HI11-S/EZ standard auxiliary contact for EZ separate mounting Type -G only 38 19 53 37 M4 100 25 125 103.5 85 10 27 21.8 11 44 19 109 38 62.5 3 18 65.5 77 103,5 85 Neutral conductor module for (high-capacity) contact module 19 44 109 Insulated enclosures for surface mounting CI19EA-PKZ2 CI19EB-PKZ2 CI19ED-PKZ2 150 Drilling dimensions 125 175 12,5 99,5 200 200 46 150 130,5 150 CI23EA-PKZ2 12,5 CI23EB-PKZ2 187,5 Drilling dimensions 187,5 162 225 12,5 99,5 250 250 46 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Dimensions 130,5 150 12,5 08/091 Moeller HPL0211-2001/2002 Insulated enclosures for flush mounting Door coupling handles E-PKZ2 E-54-PKZ2 (R)H-PKZ2 E 54-PKZ 2 7.5 (R) H-PKZ 2 with serial no. 01 48 64 155 7 M4 155 70 64 Mounting aperture for 1.5 – 16 mm panel thickness Mounting aperture for 2 – 50 mm panel thickness 19.5 62 17 48 62 171 43 111 130 l o 104 E-PKZ 2 123 + 93 93 At least 100 mm 91 up to cover hinge max. 6 mm Three-phase commoning links Three-phase commoning links Terminal Shroud for unused terminals B3.1/3-PKZ2 B3.1/2-PKZ2 BK50/3-PKZ2 HB-3-PKZ2 222 75 140 25 84,5 78,5 60 33 33 18 4,2 50 4,5 Mechanical interlock for (high-capacity) contact module MV-PKZ2 10 15 4,5 56,5 36 14,6 149 21 59 10 1,5 128,5 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Dimensions 08/092 Moeller HPL0211-2001/2002 Component adapters AD40/5(10)-1 AD40/5(10)-2 147 144 75 72 22,5 125 230 Motor-Protective Circuit-Breakers PKZ2 Motor-Protective Circuit-Breakers Dimensions 86 70
Documentos relacionados
Moeller - Eletrotrafo
MFD-Titan Alimentação Total de entradas Digitais Entradas Digitais configuráveis como analógicas D-10V 10Bits Saídas digitais a relé Saídas analógicas D-10V 10Bits Saídas digitais a transistor Disp...
Leia maisTronics Brasil – Lista de Produtos
Consulte-nos Consulte-nos Consulte-nos Consulte-nos Consulte-nos Consulte-nos Consulte-nos Imediata Imediata Imediata Consulte-nos Consulte-nos Consulte-nos Imediata Consulte-nos Consulte-nos Consu...
Leia maisRentabilidade Diaria
Fundos Executive RF (D-1) - cota de fechamento Safra Executive Premium Safra Executive Safra Executive Corporate RF Safra Executive Max RF Safra Executive Profit Safra Executive Special Safra Execu...
Leia mais