Chillers com Fluido Refrigerante de Baixo GWP
Transcrição
Chillers com Fluido Refrigerante de Baixo GWP
Projeto Demonstrativo para o Gerenciamento Integrado no Setor de Chillers Chillers com Fluido Refrigerante de Baixo GWP Luciano de A Marcato – Daikin 27/04/ 2016 – Sâo Paulo Execução Implementação Realização Ar Condicionado: da Negócio Daikin A única empresa que produz fluidos refrigerantes , compressores e equipamentos de AVAC 89% Divisão Química: Diversos produtos , mas complementares ao negócio de Ar Condicionado - Diferentes tipos de Flúor-Carbonos ( Fluidos Refrigerantes), flúor-polímeros, flúor-elastômeros 8% 3% Consolidated sales by business segment FY14 Outros: Peças de Aviões , Sistemas CADCAM e Sistemas de Computação Gráfica ; Chillers com Refrigerantes de Baixo GWP Agenda Refrigerantes Baixo GWP • • • • • • • • • • • • ODP GWP CFC HCFC HFC & HFO Critérios para escolha de fluidos refrigerantes Panorama Global AHRI – AREP Low GWP project Europa F-Gas Estados Unidos SNAP / ASHRAE 34 Toxidade / Flamabilidade Mitos Liderança Daikin Resumo Nova Agenda Mundial Nova Agenda Mundial Camada de Ozônio – CFC & HCFC Gases Protocolo de Montreal CFC – Cloro Flúor Carbono HCFC – Hidro Cloro Flúor Carbono Destruição da Camada de Ozônio Estratosférico estratosfera 40 km 25 km 15 km São Gases Efeito Estufa Produção e Consumo são controlados pelo Protocolo de Montreal . Emissões não são controladas. Destruição da Camada de Ozônio e Mudanças Climáticas pelo Efeito Estufa são tratadas de forma separada , embora haja inter-relação cientificamente comprovada entre ambas Gases Efeito Estufa (Kyoto) “Greenhouse Gases” Dióxido de Carbono- CO2 Metano - CH4 Oxido Nitroso- N2O The F-Gases: HFC – hidro flúor carbono PFC – perflúor carbono SF6 - Hexafluoreto de Enxofre Gases Efeito Estufa (Kyoto) HFCs 40 km Não atacam a Camada Ozônio Estratosférico 25 km troposfera 15 km São Gases Efeito Estufa Emissões não são controladas. pelo Protocolo de Kyoto. Outros Gases de Efeito Estufa segundo Protocolo de Kyoto : Dióxido de Carbono (CO2), metano, nitratos , perfluorcarbono Hexa Fluoreto de Enxofre(SF6) – Todos controlados; Ozônio, hidrocarbonetos – NÃO controlados. Gases Efeito Estufa (Kyoto) O impacto ambiental de quaisquer substâncias depende Da Quantidade EMITIDA da Substância e Das Propriedades da Substância Gases Efeito Estufa (Kyoto) O impacto ambiental depende Da quantidade de eletricidade usada (o que tem implicações quanto a eficiência energética) e A quantidade de fluido emitida durante sua operação e seu GWP (Potencial de Aquecimento Global) Gases Efeito Estufa (Kyoto) Greenhouse gases Absorvem radiação infra vermelha e podem afetar o clima enquanto existirem na atmosfera ( sem ser degradados ou decompostos ) Global Warming Potential (GWP) É uma medida sobre um período FIXO de tempo sobre o efeito UM quilograma ( kg ) da substância em questão de comparado a UM quilograma ( kg ) de CO2 no mesmo período . Leva em consideração a efetividade de absorção da substância e a sua persistência . A persistência do CO2 é ignorada . Gases Efeito Estufa (Kyoto) PBH – Programa Brasileiro de Eliminação de HCFCs Evolução Consumo CFCs e HCFCs , antes e depois do PBH Gases Efeito Estufa (Kyoto) Global Warming Potentials ( base 100 anos) CO2 Metano Óxido Nitroso HFC-152a HFC-134a HFC-125 Fluoroform PFC-14 SF6 Emissões Durante Anos 2000 ( Tons) 1 30,800,000,000 21 310 350,000,000 11,000,000 140 1430 2800 100,000 11700 7,000 6500 15,000 23900 6,000 Gases Efeito Estufa (Kyoto) 6 Radiative Forcing since 1765, Wm -2 5 Projected Clim ate Forcing, using "Best Estim ate" Scenarios ODS são Ozone Depleting Substances Controladas pelo Protocolo de Montreal 4 3 Carbon Dioxide 2 Methane 1 SF 6 Nitrous oxide ODS 0 1990 2010 2030 2050 Year 2070 PFCs 2090 HFCs GWP – Global Warming Potential • Este é o fator preponderante nas discussões sobre controle de fluidos Refrigerantes - TEWI GWP - Nenhum impacto se o Refrigerante ficar DENTRO do chiller! TWEI – Impacto Total Combinado – direto e indireto . Global Warming Potential (GWP) • • • • GWP é medido segundo o impacto relativo de um fluido refrigerante no aquecimento global se comparado ao CO2. Todos fluidos de efeito estufa tem um valor determinado de GWP . Este valor é usado para comparar a capacidade das diferentes substâncias em “segurar” o calor na atmosfera se comparado ao potencial do dióxido de carbono ( CO2), assim como a taxa de decomposição de cada fluido / substância (representa a quantidade removida da atmosfera após determinado período em anos) Estes períodos são cotados pois substâncias com GWPs diferentes podem ter maior ou menor impacto de acordo com sua vida útil na atmosfera , motivo pelo qual a taxa de decomposição deve ser citada para fins de comparação ( 20 anos , 100 anos ou 200 anos por exemplo )Para a maior parte dos gases o GWP diminui com o passar dos anos . Isso ocorre pois eles são naturalmente removidos da atmosfera por mecanismos naturais e isso influencia seu efeito sobre o meio ambiente. Contudo alguns gases CFCs tem longa vida na atmosfera , sendo que seu efeito combinado do GWP ao longo de 100 anos ser bem mais danoso que o GWP de 20 anos . A determinação do valor de GWP permite aos governos e órgãos reguladores comparar o efeito de diferentes emissões e a redução de diferentes gases do efeito estufa . O Metano , por exemplo , tem significante contribuição no aquecimento global e tem GWP = 21. Isso significa que comparativamente o seu efeito é 21 vezes maior que o o CO2; O índice mais comumente citado é o de 100 anos de horizonte com base no AR5 do IPCC Fifth Assessment Report, 2014 . Falando sobre Refrigerantes…. • CFC – HCFC – HFC – HFO Falando sobre Refrigerantes…. • CFC – HCFC HFC & HFO • HFO – Hidro flúor oleofinas são substâncias químicas cuja composição tem flúor e carbono ligados por pelo menos uma dupla ligação entre os átomos Essas substâncias não agridem a camada de ozônio ( ODP ZERO ) e geralmente tem GWP baixo HFO – Menor vida na atmosfera , menor impacto Falando sobre Refrigerantes…. • Atualmente • Preocupações – HCFCs terão seu uso descontinuado com Phase Out em 2020 para novos equipamentos segundo o Protocolo de Montreal – HFCs não tem data global de Phase Out • Europa com Phase Out dos Fluidos Refrigerantes “F Gas “ para A/C Automotivo no início de 2013 • Começou a Batalha dos Refrigerantes entre o CO2 e o HFO-1234yf para A/C Automotivo – HFCs não tem ODP • Isso é bom – HFCs tem GWP • Isso já não é Bom ! • HFC-134a GWP = 1300 • HFC-410a GWP = 2088 – HFCs estão sendo controlados quanto ao futuro uso devido a seus impactos como gases de efeito estufa Waxman – Markey Bill GWP Index para 100 anos segundo IPCC Latest Report Is Assessment Report 4 (AR5) 23 Fatores a Considerar quando da escolha do Fluido Refrigerante Recursos Energéticos Peak Load Aquecimento Global ODP = Zero Viabilidade Alto COP Alta Eficiência Eliminar CFC Segurança Baixa Toxidade Baixo GWP Carga Reduzida Eliminar HCFC Flamabilidade Baixa ou Nula Baixas Emissões Compacto e Leve Confiabilidade Facilidade de Uso Próxima Geração de Refrigerantes Refrigerante Critérios de Escolha Refrigerantes “Verdes” Environmentally friendly são mais reativos por natureza HIDROGENIO EX.: Propano (R-290) Inflamável ODP = 0 GWP = 20 Só um pouco inflamável !!! A mudança dos CFCS para os HFCs introduziu desafios de compatibilização com gaxetas , lubrificantes e verniz de isolamento elétrico dos motores Tóxico Gases Fluorados ( CFC )com boa estabilidade , inertes a outros materiais e com boa classificação de segurança CLORO FLÙOR Longa Vida na Atmosfera (Halogenados) Refrigerante Critérios de Escolha Refrigerantes tem características únicas de operação e uso – A escolha nunca é feita observando-se somente um fator , mas a análise criteriosa de diversos pontos : – – – – – Segurança Eficiência Energética Disponibilidade Fatores Economicos GWP Fatores operacionais podem ser diferentes : – – – – Pressões Incompatibilidade de lubrificantes Incompatibilidade de metais , polímeros e ligas Níveis de flamabilidade Diferentes necessidades para cada aplicação Escolha do Compressor Condição Padrão AHRI é de LIFT(Delta H) WATER COOLED CHILLER DUTY 18 32 POSITIVE DISPLACEMENT, ROTARY, SCROLL, RECIP, SCREW 16 152a DELTA H, (Btu/lb) 14 410A 12 134 22 143a 10 507 502 125 8 6 11 134a 500 123 124 12 113 114 4 CENTRIFUGAL 2 Compressor Capacity 0 .1 Axial 1 10 100 CFM/TON 300 a 700 tons → 900 a 2100 CFM = Compressor Centrífugo Centrifugal Screw Rotary Nota : O Refrigerante HFC-134a pode ser usado em compressores parafuso para aplicações de HIGH LIFT (A/C screw or HP) ou em aplicações de alta capacidade e LIFT pequeno Scroll Recip 0 1 10 100 1,000 CFM 10,000 100,000 1,000,000 Uso Refrigerante - HFC R134a CAPACIDADE VOLUMETRICA 17 CFM/Ton = compressor grande girando devagar 200 113 114 MASSA MOLECULAR 1.5 CFM/Ton 123 150 Mistura de R-32 e R125 124 12 125 502 100 134a 22 500 410A 32 50 Nota : HFC R134a tem propriedades muito boas quanto ao meio ambiente e segurança 134 507 143a 11 152a 3 CFM/Ton = compressor pequeno girando rápido 0 .1 1 CFM/TON 10 100 Novas Gerações Futuras de Refrigerantes • Trabalho já começou para futura substituição dos HCFCs e HFCs – Procure no Google HFO-1234yf da Dupont • Propriedades Similares ao HFC-134a • OPD = 0, GWP < 10 • Tecnicamente inflamável • CO2 é a bola da vez para sistemas menores , com climas temperados e baixos HPs • É uma Previsão Segura indicar que para um chiller vendido hoje , que durante sua vida útil deve haver uma nova mudança de fluido refrigerante – SEM PÂNICO POR FAVOR ! Isso já aconteceu antes no segmento de HVAC/R! Projeto AHRI Refrig. Low-GWP Projetos completados : • Revisão de Normas e Regulações sobre Uso de Fluidos Refrigerantes com Valores de GWP abaixo de 20 em Aplicações de AVAC&R • Definição da configuração de Ar Condicionado Residencial e Sistemas Bomba Calor utilizando Hidrocarbonetos , Amônia , Dióxido de Carbono e fluido HFO-1234yf como refrigerante Refrigerantes e definição de Requisitos Mínimos de Segurança • Pesquisa de Compatibilidade de Materiais e Lubrificantes para Fluidos Refrigerantes de Baixo GWP – Fase 1 - : Estabilidade Química e Térmica de Fluidos Refrigerantes de Baixo GWP com Lubrificantes • Avaliação de Riscos para Sistema Bomba Calor Residenciais usando Fluidos Refrigerantes Inflamáveis da Classe 2L • Avaliação de Riscos para Sistema de Refrigeração usando Fluidos Refrigerantes Inflamáveis da Classe A2L Programa em andamento: Low-GWP AREP Low-GWP AREP Introduction Trabalho em conjunto com a indústria para identificar fluidos refrigerantes potenciais de baixo GWP Coordenar Testes de Performance com fabricantes Diversas indústrias fabricantes de equipamentos propuseram planos de testes de acordo com seus produtos e interesses técnico comerciais O Envio dos Relatórios de Testes foram diretamente enviados ao Comitê Técnico Low-GWP AREP daAHRI Refrigerante Alternativos Baseline Refrigerante R-134a Composição (Massa%) Classificação GWP100 AC5X R-32/R-134a/R-1234ze(E) (7/40/53) ARM-41a R-32/R-134a/R-1234yf (6/63/31) D-4Y R-134a/R-1234yf (40/60) N13a R-134a/R-1234yf/R-1234ze(E) (42/18/40) N13b R-134a/R-1234ze(E) (42/58) XP-10 R-134a/R-1234yf (44/56) AC5 R-32/R-152a/R-1234ze(E) (12/5/83) ARM-42a R-134a/R-152a/R-1234yf (7/11/82) R1234yf R1234yf 100 R1234ze R1234ze 100 R600a R600a 100 R290/R600a R290/R600a (40/60) A1* A1* A1* A1* A1* A1* A2L* A2L* A2L A2L A3 A3* *estimated safety group rating, a safety group has not yet been assigned by ASHRAE in accordance with requirements of ASHRAE Standard 34-2010. 622 943 574 604 604 631 92 117 4 6 <20 <20 Refrigerante Alternativos Baseline Refrigerante R410A Composição (Massa%) Classificação GWP100 R-744 ARM-70a R-744 R-32/R-134a/R-1234yf 100 (50/10/40) A1 A2L* 1 482 D2Y60 R-32/R-1234yf (40/60) A2L* 272 DR-5 R-32/R-1234yf (72.5/27.5) A2L* 490 HPR1D R-32/R-744/R-1234ze(E) (60/6/34) A2L* 407 L41a R-32/R-1234yf/R-1234ze(E) (73/15/12) A2L* 494 L41b R-32/R-1234ze(E) (73/27) A2L* 494 R32 R32 100 A2L 675 R32/R134a R-32/R-134a (95/5) A2L* 713 R32/R152a R-32/R-152a (95/5) A2L* 647 *estimated safety group rating, a safety group has not yet been assigned by ASHRAE in accordance with requirements of ASHRAE Standard 34-2010. Refrigerantes com Baixo GWP 1800 R-134a (GWP=1300) replacements R-404A (GWP=3900) replacements R-410A (GWP=2100) replacements R-22 (GWP=1810) replacements 1600 GWP100 Value 1400 A1 1200 A2L 1000 A3 B2L 800 600 400 200 0 Alternative Refrigerante Candidates Visão Geral dos Testes Dezesseis (16) organizações / empresas norte americanas e cinco (5) organizações / empresas internacionais conduziram os testes de performance Seis (6) empresas produtoras de Refrigerante forneceram trinta e oito (38) tipos diferentes de fluidos refrigerante Teste cobriram as seguintes aplicações / equipamentos – Condicionadores de Ar e Bomba Calor s (air-source, water-source, VRF, unitarios, mini-split) – Chillers (parafuso a ar e água e centrifugas) – Aquecedores de água bomba calor – Refrigeração (refrigeradores comerciais, maquinas de Gelo) – Transporte Frigorificado – Condicionadores de Ar para ônibus Testes Efetuados Teste de Compressor em calorímetro Testes de Sistemas Drop-In – Permitidas mínimas modificações Testes de Sistemas “soft-optimization” – Sistemas são modificados para utilização de refrigerantes alternativos utilizando componentes padrão Test Types Number of candidates being tested Number of products being tested Compressor Calorimeter 28 35 Drop-in 27 30 Soft-optimization 18 19 Note: Number of candidates and product types in the table are based on approved test plans submitted by testing entities. Actual numbers may vary due to testing entities’ schedule changes. TEST #25 – Chillers Cond. a Ar TEST #25 – Chillers Cond. a Ar Aplicação de Fluidos Refrigerantes J & E Hall Special Chiller Packages Custom built chiller packages • Designed & manufactured to meet customer requirements Extreme operating conditions • 20 kW up to 2,000 kW and above • Fluid outlet temperature down to minus 90.0°C • Ambient temperatures up to 50.0°C • Hazardous area installation Wide choice of refrigerants • Any refrigerant (Ammonia, HFC, CO2 & Hydrocarbons) Design • Any design code or standard • PED, PD 5500,TEMA,ASME,API, Customer Specifications • 3D modelling of packages Aplicação de Fluidos Refrigerantes Aplicação de Fluidos Refrigerantes Passado A/C Residential HCFC22 A/C Comercial HCFC22 Chiller Centrífugo Chiller Parafuso Refrigeração Comercial Container Frigorificado CFC12 R502 Vending Machine R410A R407C R410A HCFC123 HCFC22 HFC134a Amônia R502 CFC12 HFC134a R407C HFC134a HCFC22 Amônia HCFC22 HFC134a R32 R410A R32 R410A (R407C) HFC134a HCFC22 HFC134a HCFC22 CFC12 Futuro HCFC22 CFC12 A/C Móvel Refrigerador Doméstico HCFC22 CFC11 CFC12 Presente R1234yf HFC245fa HFC134a R407C R1234ze R407E R404A R507A R410A CO2 HC HFC134a R&D R404A Amônia HFC134a HFC152a CO2 R1234yf? HFC134a CFC12 HFC134a CFC12 R600a(Isobutano) HFC134a R600a(Isobutano) CO2 R290(Propano) Tendência de Conversão de Refrigerante – Visão Global ・Under Montreal protocol, developing countries have to submit HCFC Phase-out Management Plans to the UN is approaching, conversion plans from HCFC22 are urgently being developed. ・Establishment of standards and regulations, technical support, Refrigerante supply, and servicing infrastructure are essential for Refrigerante conversion. Daikin provides necessary information at international conferences. UN Trends: Montreal Protocol related ・UNEP has established the Multilateral Fund for the Implementation (MLF) by the contributions from developed countries to perform financial and technical assistance for developing. ・There is recognition of candidates for alternative Refrigerantes such as HFC32 and propane that have low GWP. The Fund does not agree for R410A. Europe ・F-gas regulations were revised And became effective from 2015. (Main points: phase-down of HFC, prevention of leaks/recovery of HFC, etc) China North America ・Commercial AC: MLF approved the conversion plan to HFC32/R410A ・Residential AC: ・ MLF approved conversion plan to R290 ・Chinese standards are currently being revised. ・Proposal to UN to reduce total HFC (Proposal by three-countries: U.S., Canada, and Mexico) ・Recognition of HFC32 as alternative Refrigerante candidate in emerging countries by the Environmental Protection Agency/ State Department Middle East/Africa Thailand ・MLF approved the conversion to HFC32 ・ME counties are interested in HFC32 as a solution for high temperature regions ・MLF approved the conversion to HFC32. ・Conversion is started from 2015 India ・HPMP is currently being investigated. HFC32 is one of candidate. ・Daikin has established the servicing infrastructure to disseminate the energyefficient product using HFC32 as part of a bilateral credit FS program of the Japanese government. Japan ・Japanese F-gas regulations will be effective. Conversion to low-GWP Refrigerantes is an important theme. ・Relaxation of regulation for mildly flammable Refrigerantes is currently undergoing Indonesia ・ MLF approved the conversion to HFC32 ・A/C sector will convert to HFC32 by 2015. ・Import ban of HCFC equipment is started from 2015 Emerging countries Developed countries Legislação Européia NOVAS LEGISLAÇÕES % Objetivo até 2050 -80% de emissões de CO2 Política atual -40% de emissões de CO2 O equipamento HVAC gera emissões de gases de estufa: • Emissões DIRETAS, devido a possíveis vazamento de fluido refrigerante para a atmosfera. • Emissões INDIRETAS, relacionadas com o consumo de energia do equipamento Tempo Principais fatores impulsionadores do mercado HVAC Europa – Legislação F-Gas A legislação F-Gas foi introduzida em 2006, buscando proteger o meio ambiente pela redução das emissões de gases efeito estufa a partir dos gases fluorados ( F-gases). Uma revisão da legislação F-Gas foi aprovada e publicada no jornal oficial da União Européia em Maio de 2014 e foi aplicada e validada a partir de 1 de Janeiro de 2015. Consequências da Nova Legislação F-Gas: • Uma redução planejada no consumo dos fluidos refrigerantes da família dos HFCs com diferentes estágios progressivos de redução ao longo dos próximos anos com uma meta final de até 80% em 2030 (redução em termos comparativos em Tons de CO2 equivalente, comparado ao consumo médio entre 2009 e 2012. • Deve-se atentar que não se trata de um phase-out dos HFC ( afinal a meta de redução final não é ZERO ) mas sim um “phase-down” dos HFCs que ainda estarão disponíveis para uso depois de 2030 conforme legislação hoje vigente Europa – Legislação F-Gas Consequências da Nova Legislação F-Gas : A legislação The F gas também inclui banir certos tipos de HCFs para alguns produtos , mas não para chillers. Isso significa que vai haver uma transição gradual no mercado de chillers devido ao phase down dos HFCs , mas também que não existe restrição proibitiva ao uso de R410A or R134a em aplicações de chillers. A maior mudança da legislação F Gas foi relativa ao uso do R404A e outros Refrigerantes com GWP (*) ≥2500 no setor de refrigeração. A partir de 2020 , os Fluidos Refrigerantes com GWP ≥ 2500 (como o R404A, cujo GWP = 3922) serão banidos em todas as novas instalação estacionárias de refrigeração comercial e industrial . Possível revisão de normas de segurança devido ás características de flamabilidade das novas famílias de refrigerantes (e.g. EN 378) (*) The Global Warming Potential (GWP) measures the global warming effect of the Refrigerante compared to CO2 (GWP = 1). Europa – Legislação F-Gas Para chillers com compressores PARAFUSO a Daikin identificou o R1234ze como melhor fluido refrigerante para substituir o R134a . Será iniciada uma transição gradual a partir de 2017 Por que o R1234ze? • Performance Otimizada Impacto limitado na eficiência *. • Ambientalmente Aceitos GWP extremamente baixo (6). • Procedimentos de Serviços Simplificados Refrigerante Puro Por que em 2017? • Esperado aumento em larga escala da disponibilidade e maior competitividade em termos de preço . • Revisão das Normas Européias e Locais para de forma segura e planeja aceitarem Novos Fluidos Refrigerantes. Mairo custo inciail dos equipamentos ( chillers ) • • Preço atual do refrigerante é MAIOR que R134a Projeto mais complexo devido as Normas atuais de projeto da UE * Possibility to maintain seasonal efficiency (ESEER) at the level of todays’ R134a units. Estados Unidos - SNAP • SNAP • The Significant New Alternatives Policy (SNAP) Program is the US Environmental Protection Agency’s (EPA) program to evaluate and regulate substitutes for the ozone-depleting chemicals Estados Unidos - SNAP Estados Unidos - ASHRAE 34 • Toxidade – ASHRAE classifica como “A” (Baixa Toxidade) ou “B” (Alta Toxidade) • Flamabilidade - ASHRAE classifica como 1 (não inflamáveis) , 2L (Flamabilidade Muito Baixa), 2 (Baixa Flamabilidade) ou 3 (Alta Flamabilidade) ASHRAE Standard 34 United States - ASHRAE 34 • Toxidade – ASHRAE 34 • A (Baixa Toxidade) ou • B (Alta Toxidade) • Flamabilidade - ASHRAE 34 • 1 (sem propagação de fogo) • 2L (Flamabilidade Muito Baixa) – Efeito de Ignição não é tão grande , e tipicamente de difícil ignição. Baixa velocidade de propagação da chama • 2 (Baixa Flamabilidade) • 3 (Alta Flamabilidade) 2L ainda não é reconhecido pelos códigos prediais na América do Norte Flamabilidade e Toxidade Incr easing Flammability Safety Group Higher Flammability Lower Flammmability No Flame Propogation Propane (R290) A3 B3 A2 B2 A2L R134a R410A R22 A1 Ammonia (R717) B2L R123 B1 Increasing Toxicity bility mability e tion Flamabilidade e Toxidade A2 Alternativas ao R134a HFO1234yf HFO1234ze R134a R410A R22 A2L R32 DR55 B2 Ammonia (R717) B2L HFO1233zd A1 R513A R450A Alternativa ao R410A (67% R32) R123 B1 Increasing Toxicity Blends HFO/R134a Boa Alternativa ao R410A – Aplicação Global aumentando Alternativa ao R123 Mito: HFCs estão sendo banidos • Ações SNAP são para aplicações específicas HFCs SÃO aprovados para uso em Aplicações de A/C Mito: HFCs estão sendo banidos • • • EPA está avaliando aplicar SNAP para chillers Proposta conjunta AHRI e NRDC – Jan 1, 2025 Em 29 Março 2016 – EPA propôs data tentativa de 01 Janeiro 2024 Mito: Europa já baniu os HFCs , incluindo R134a e R410 • Europe NÃO baniu R134a para chillers – Não há restrições para fluidos refrigerantes com GWP abaixo de 2500 para aplicação em chiller • R134a = 1300, R410A = 2088 – A legislação F-Gas inclui algumas restrições contra alguns tipos de HCFs em certos tipos de produtos/aplicações , mas não aplicáveis n o momento para o uso de R410A ou R134a em aplicação de chiller – Maior focus em aplicações com alto nívei de emissões No mercado de chillers é esperada transição mais gradual Mito: Europe já baniu os HFCs , incluindo R134a e R410 Mito: GWP baixo é sempre melhor • Contribuição ao Aquecimento Global é baseada nos efeitos diretos ( emissão ) e indiretos ( eficiência energética ) dos fluidos refrigerantes: – Um fluido de baixo GWP não vai ser necessariamente melhor se tiver prejuízo a eficiência do sistema de AVAC Hoje ainda não existe Refrigerante do Grupo A1 que seja uma melhor alternativa ao R134a ou ao R410A ! Teste de A/C Chiller com R513A R450A R513A Impacto negativo no (TEWI) 58 [Data source: AHRI Low-GWP AREP Report 007, 2012] Teste de A/C Chiller com R513A Impacto negativo no (TEWI) 59 (Data source: AHSRAE Orlando 2016, Conference Paper Session 5) Teste de A/C Chiller com R513A (Data source: AHSRAE Orlando 2016, Conference Paper Session 5) Impacto negativo no (TEWI) 60 Como se comparam contra o R134a? • A2L deve aguardar alteração dos códigos prediais dos EUA e Canadá Refrigerant Composition (Mass %) Classification GWP100 R134a R513A (XP10) R134a/R1234yf (44/56) R450A R134a/R1234ze (42/58) R1234yf R1234ze A1 A1 A1 A2L A2L R134a ainda é a melhor opção atualmente 1300 631 604 4 6 Refrigerante - Resumo Refrigerant R134a R450A R513A R1234yf R1234ze R410A R32 DR55 R125 R22 R1233zd ASHRAE 34 GWP100 (AR5) Composition Classification A1 1300 A1 547 42% R134a / 58% R1234ze A1 572 44% R134a / 56% R1234yf A2L 1 A2L 1 A1 1924 50% R32 / 50% R125 A2L 677 A2L 675 67% R32 /26% R1234yf / 7% R125 A1 3170 A1 1760 A1 1 Legislação de Refrigerante vai levar a Futuras Inovações • Preocupações Ambientais vão continuara guiar as principais mudanças na Indústria de Refrigerantes – Globalmente , o mercado de AVAC&R está trabalhando de forma ativa e responsável na transição de substâncias que contribuem com o aquecimento global e as mudanças climáticas • Necessário agir de forma rigorosa e responsável – Pressão das agências reguladoras , da mídia e das forças do mercado competitivo tem resultado em um ambiente complexo com mensagens de difícil interpretação e correto entendimento • É necessário que as discussões sejam baseadas em fatos reais • Futuras discussões sobre fluidos refrigerantes devem focar em mudanças climáticas ( equipamentos com Alta Eficiência Energética e Fluido Refrigerante de baixo GWP) – Um GWP muito baixo pode significar o comprometimento de outros fatores Refrigerante R32 Europe Nov 2013 R32 air conditioners Japan Nov-12 on sale in 30 Developing Countries India – Mar-13 Thailand Apr-14 countries (As of May 2014) Australia Jan 2014 R32 – replacements for R410a, ODP: 0, GWP: Low Implementação do R32 Resumo Final • HFCs e HFOs representam hoje as melhores escolhas para novos equipamentos em se tratando de chillers • HFCs (R134a e R410A) são hoje as escolhas corretas para uso de Fluidos Refrigerantes de Classe A1 • Busque evitar o uso de HFCFs , pois existem melhores opções ambientalmente aceitas • Focar em boas práticas de manutenção e em eficiência Appendix – Common Terms ˃ ˃ ˃ ˃ ˃ ˃ ˃ ˃ CFCs – ‘ are any of several simple gaseous compounds that contain carbon, chlorine and fluorine, that were used as Refrigerantes, cleaning solvents, and aerosol propellants and in the manufacture of plastic foams. Common examples are R-11 and R-12, have not been used in new HVAC equipment in North America since the mid 1990s. HCFCs - Hydrochlorofluorocarbons are those chemicals that are composed of fluorine, carbon, hydrogen, and at least one chlorine atom connected by single bonds between the atoms. HCFCs are ozone-depleting substances, generally with shorter atmospheric lifetimes than CFCs and lower ozone depletion potentials (ODP). HCFCs are subject to phase-out by the Montreal Protocol and specific legislation in the US. Common examples are R-22 and R-123. HFCs – Hydrofluorocarbons are those chemicals that are composed of fluorine, carbon, and hydrogen and connected by single bonds between the atoms. Hydrofluorocarbons are non-ozone-depleting substances and are considered long term replacements for CFCs and HCFCs. Recent concerns around global climate change are focusing more attention on the global warming potential (GWP) of these Refrigerantes. HFC examples are R-134a and R-410A. HFOs - Hydrofluoro olefins are those chemicals that are composed of fluorine and carbon and have at least one double bond connecting the atoms. Hydrofluoro olefins are non-ozone-depleting substances with relatively low GWP values. ODP – Ozone Depletion Potential is a number that refers to the amount of ozone depletion caused by a substance. The ODP is the ratio of the impact on ozone of a chemical compared to the impact of a similar mass of CFC-11. Thus, the ODP of CFC-11 is defined to be 1.0. Other CFCs and HCFCs have ODPs that range from 0.01 to 1.0. HFCs have zero ODP because they do not contain chlorine. GWP - Global Warming Potential is a number that refers to the amount of global warming caused by a substance. The GWP is the ratio of the warming caused by a substance to the warming caused by a similar mass of carbon dioxide. Thus, the GWP of CO2 is defined to be 1.0. CFC-12 has a GWP of 8,500, while CFC-11 has a GWP of 5,000. Various HCFCs and HFCs have GWPs ranging from 93 to 12,100. Water, a substitute in numerous end-uses, has a GWP of 0. Montreal Protocol - The international treaty governing the protection of stratospheric ozone. The Montreal Protocol on Substances That Deplete the Ozone Layer and its amendments control the phase out of ODS (ozone depleting substances) production and use. Under the Montreal Protocol, several international organizations report on the science of ozone depletion, implement projects to help move away from ODS, and provide a forum for policy discussions. In addition, the Multilateral Fund provides resources to developing nations to promote the transition to ozone-safe technologies. The full text of the Montreal Protocol is available from the United Nations Environmental Programme (UNEP). SNAP ‐ The Significant New Alternatives Policy (SNAP) Program is US Environmental Protection Agency’s (EPA) program to evaluate and regulate substitutes for the ozone‐depleting chemicals that are being phased out under the stratospheric ozone protection provisions of the Clean Air Act (CAA). In Section 612(c) of the Clean Air Act, the Agency is authorized to identify and publish lists of acceptable and unacceptable substitutes for class I or class II ozone‐depleting substances.67The purpose of the program is to allow a safe, smooth transition away from ozone‐depleting compounds by identifying substitutes that offer lower overall risks to human health and the environment. Referencias / Contato http://www.foodcoldchainconference.com/ http://www.fluorocarbons.org/library/presentations Luciano de Almeida Marcato Gerente Vendas – Daikin Applied E-mail – [email protected] Telefones : +55 11 3123 2525 / 11 3123 2535 Celular : +55 11 99854 1331 / 98953 1354 http://www.daikin.com/press/2015/151209/index.html http://gfpf-forum.org/index.php/resource-center/asia-pacific http://www.daikin.com/csr/information/influence/Daikin's_Policy.pdf http://www.ahrinet.org/ahri+low_gwp+alternative+Refrigerante s+evaluation+program.aspx http://ec.europa.eu/clima/policies/f-gas/legislation/docs/fluorinated_greenhouse_gases_en.pdf https://www.epa.gov/sites/production/files/documents/Energy_and_Global_Warming_Impacts_of _HFC_Refrigerants.pdf http://www.ahrinet.org/App_Content/ahri/files/RESEARCH/AREP_Final_Reports/AHRI%20LowGWP%20AREP-Literature%20Review.pdf Execução Implementação Realização