Thermo. Titr. Application Note No. H-098 Title: Determination of Hydrofluoric Acid in Silicon Etch solutions Scope: Determination of fluoride in industrial solutions such as acid etching mixtures. Principle: Acidic solutions of fluoride react exothermically with boric acid according to the equations: H3BO3 + 3H+ + 3F- « HBF3 (OH) + 2H2O (1) HBF3 (OH) + H+ + F- « HBF4 + H2O (slow ) ( 2) H3BO3 + 4H+ + 4F- « HBF4 + 3H2O When fluoride is the analyte (and boric acid the titrant), only reaction (1) is observed, and hence 3 mol of fluoride reacts with 1 mol of boric acid. The titrations are carried out in plastic titration vessels (e.g., 6.1450.210 PFA titration vessel, 10-90mL), as acidic fluoride solutions react with glass vessels. A fluoride-resistant 6.9011.040 Thermoprobe is also used in this determination. Reagents: 0.7 mol/L boric acid solution Method: Basic Experimental Parameters: Titrant delivery rate (mL/min.) 2.5 No. of endothermic endpoints 1 Data smoothing factor 80 Procedure: An aliquot of sample solution is weighed into a titration vessel. D.I. water is added to make the volume to ~30mL. The solution is titrated with standard H3BO3 solution to a single exothermic endpoint. The titration program includes a 120 second delay under stirring before titrant addition commences. This ensures a satisfactory equilibration of temperature. The etch solution analysed here comprised a very Copyright Metrohm 2009 Page 6 of 14 high proportion of nitric acid with a small amount of hydrofluoric acid. An average sample mass of approximately 20g was employed. Copyright Metrohm 2009 Page 7 of 14 Results: Replicate analysis of a used etch solution from etching of silicon substrate: % HF = 0.049, 0.047, 0.047, 0.046 Calculation: %HF = (( titre, mL - blank, mL ) ´ M H3BO 3 ´ FW HF ´ 3 ´ 100 ) (sample vol, mL ´ 1000 ) Thermometric Titration Plot: Legend: Red = solution temperature curve Black = second derivative curve Blank determination 0.240 y = 0.0084x - 0.0059 2 R = 0.9837 0.220 mL 0.7 mol/L H3BO3 Note: the less than ideal linearity is a function of the extremely small titration volumes (~0.14 – 0.24mL) experienced when analyzing the sample. However, the fact that the titration volume was seen to vary with sample mass shows the validity of the method in analyzing small amounts of HF Blank determination - HF in etch solution 0.200 0.180 0.160 0.140 0.120 17 19 21 23 25 g etch solution Copyright Metrohm 2009 Page 8 of 14 27 29
Documentos relacionados
AN-H-129 - Metrohm
directly into a clean, dry 200 mL volumetric flask previously tared on an analytical balance. The contents are made to volume with toluene or xylene. A 25 mL aliquot is pipetted into a clean, dry t...
Leia maisMultiple response optimization for Cu, Fe and Pb determination in
For the measurement of the Cu and Fe signals, 20 μL of sample or standard emulsion was injected into the partitioned graphite tube (pyrolytic coated) and the temperature program was run. The use of...
Leia mais