GLC012 to GLC500

Transcrição

GLC012 to GLC500
Load Link
GLC012 to GLC500
Wireless Underhook Load Link
Features


















Standard single part line pull sizes ranging from 12 500
to 500 000 kg
All Aluminum frame and hardware
Heavy duty construction – 2014/A Grade
Accuracy of +/-1% of the WLL
Ships Pre-calibrated
Lightweight for easier portability
Unique design ensures that load shackles used are
always equal to the Max rating - WLL of the Load Link
Radio range with line of sight: 4000 ft. (1300 m)
Operates with one 'D' cell battery lithium 3.6V or
alkaline 1.5V.
Up to 2 years battery life.
ISM license free radio; wavelength and modulation
optimized for radio communication in industrial
environments.
Temperature range: -35°C to 60°C (-31°F to 140°F)
Potted electronics for increased water protection
Rugged field-replaceable antenna
Custom sizes on request
2 year warranty
Designed with a safety factor of 5:1 on the working
load limit
All units proof loaded to 150% of capacity.
Applications
Designed for all applications in the lifting industry,
including offshore, that do not require the load cell to be
submerged (due to radio communications). Installation is
typically under the hook (vertical) and otherwise used
horizontal for measure winch/rope and ground based
pulling applications.
Wireless Underhook Load Link
General Description
The load cell is installed in-line using two equally rated
load shackles. This load creates minute deformations of the
load link and electronics convert it into a load value, which
is transmitted to the receiving unit.
The radio transmitter, load convertor and battery are
mounted inside the load link offering a low-profile design
reducing the effect that impact has on the unit.
LSI
Rev.1.3
Page 1 of 5
Load Link
GLC012 to GLC500
Table of Contents
Features ................................................................................................................................................ 1
Applications ......................................................................................................................................... 1
General Description ............................................................................................................................. 1
Table of Contents ................................................................................................................................. 2
Specifications ....................................................................................................................................... 4
Absolute Maximum Ratings ................................................................................................................ 4
Certifications ........................................................................................................................................ 4
Materials............................................................................................................................................... 4
Dimensions........................................................................................................................................... 5
LSI
Rev.1.3
Page 2 of 5
Load Link
GLC012 to GLC500
Ordering Information
North American FCC Standard
Model
GLC012-01
GLC025-01
GLC050-01
GLC075-01
GLC100-01
GLC150-01
GLC200-01
GLC250-01
GLC300-01
GLC400-01
GLC500-01
GS550-25
Description
12 500 kg WLL Underhook Load Link ( 902-928 MHz )
25 000 kg WLL Underhook Load Link ( 902-928 MHz )
50 000 kg WLL Underhook Load Link ( 902-928 MHz )
75 000 kg WLL Underhook Load Link ( 902-928 MHz )
100 000 kg WLL Underhook Load Link ( 902-928 MHz )
150 000 kg WLL Underhook Load Link ( 902-928 MHz )
200 000 kg WLL Underhook Load Link ( 902-928 MHz )
250 000 kg WLL Underhook Load Link ( 902-928 MHz )
300 000 kg WLL Underhook Load Link ( 902-928 MHz )
400 000 kg WLL Underhook Load Link ( 902-928 MHz )
500 000 kg WLL Underhook Load Link ( 902-928 MHz )
Under Hook Hand-Held Remote Wireless Display/Receiver - FCC (902-928 MHz)
European CE standard
Model
GLC012-02
GLC025-02
GLC050-02
GLC075-02
GLC100-02
GLC150-02
GLC200-02
GLC250-02
GLC300-02
GLC400-02
GLC500-02
GS550-26
LSI
Description
12 500 kg WLL Underhook Load Link ( 868-870 MHz )
25 000 kg WLL Underhook Load Link ( 868-870 MHz )
50 000 kg WLL Underhook Load Link ( 868-870 MHz )
75 000 kg WLL Underhook Load Link ( 868-870 MHz )
100 000 kg WLL Underhook Load Link ( 868-870 MHz )
150 000 kg WLL Underhook Load Link ( 868-870 MHz )
200 000 kg WLL Underhook Load Link ( 868-870 MHz )
250 000 kg WLL Underhook Load Link ( 868-870 MHz )
300 000 kg WLL Underhook Load Link ( 868-870 MHz )
400 000 kg WLL Underhook Load Link ( 868-870 MHz )
500 000 kg WLL Underhook Load Link ( 868-870 MHz )
Under Hook Hand-Held Remote Wireless Display/Receiver - CE (868-870 MHz)
Rev.1.3
Page 3 of 5
Load Link
GLC012 to GLC500
Specifications
Parameter
Load Tension Measurement
Resolution
Accuracy
Repeatability
Radio Power
Radio Frequency
North American version
European version
Battery life
Test Condition
Min
Typ
Max
+/- @21°C
+/- @21°C
+/- @21°C
0.025
0.1
0.05
0.075
0.5
0.25
0.2
1
0.5
GLCXXX-XX
0.013
11
0.016
12
0.020
13
W
dBm
GLCXXX-01
GLCXXX-02
902
868
928
870
MHz
MHz
24
16
Month
Month
‘D’ cell lithium
‘D’ cell alkaline
18
6
Unit
% of WLL
% of WLL
% of WLL
Absolute Maximum Ratings
Parameter
Ambient temperature range
Test Condition
Operating
Storage
Min
-35
-31
-35
-31
Typ
Max
+60
+140
+65
+140
Certifications
Safety
IEC 61010-1
Radio/EMC
FCC : parts 15.247, 15.205, 15.207
Industry Canada : RSS-210
CE : EN 300 220-3, EN 301 489-3
Materials
The load cell is made of aluminum L168 2014A – T6511 with aluminum battery caps.
LSI
Rev.1.3
Page 4 of 5
Unit
ºC
ºF
ºC
ºF
Load Link
GLC012 to GLC500
Dimensions
Max Load
Model
number
GLC012
GLC025
GLC050
GLC075
GLC100
GLC150
GLC200
GLC250
GLC300
GLC400
GLC500
LSI
A
B
C
D
EØ
Unit
Weight
(in)
4.92
13.90
2.52
9.84
1.57
27557 lb
(mm)
125
353
64
250
40
12500 kg
2.3 lb
5 kg
(in)
5.08
15.35
2.52
9.84
2.17
55115 lb
11 lb
(mm)
129
390
64
250
55
25000 kg
7 kg
(in)
6.14
18.58
3.15
11.81
2.95
110231 lb
27 lb
(mm)
156
472
80
300
75
50000 kg
13 kg
(in)
6.54
19.37
3.86
11.81
3.35
165346 lb
38 lb
(mm)
166
492
98
300
85
75000 kg
17 kg
(in)
7.72
23.62
4.72
15.75
3.94
220462 lb
71 lb
(mm)
196
600
120
400
100
100000 kg
32 kg
(in)
10.24
25.98
5.51
15.75
4.72
330693 lb
117 lb
150000 kg
53 kg
157 lb
(mm)
260
660
140
400
120
(in)
11.73
28.50
5.91
16.69
5.24
440924 lb
(mm)
298
724
150
424
133
200000 kg
72 kg
(in)
13.70
32.44
5.91
18.66
5.67
551155 lb
210 lb
(mm)
348
824
150
474
144
250000 kg
95 kg
(in)
16.14
36.02
5.91
20.28
6.30
661386 lb
275 lb
(mm)
410
915
150
515
160
300000 kg
125 kg
(in)
17.32
40.31
7.87
22.60
7.09
881849 lb
426 lb
(mm)
440
1024
200
574
180
400000 kg
198 kg
(in)
19.69
42.68
7.87
23.46
7.48
1102311 lb
528 lb
(mm)
500
1084
200
596
190
500000 kg
240 kg
Rev.1.3
Page 5 of 5

Documentos relacionados

University of Mumbai

University of Mumbai Principals of the affiliated colleges, Heads of the Recognised institutions , Professor-cumDirector, Institute of Distance & Open Learning (IDOL) and the Assistant Registrars, University Sub-Centre...

Leia mais

EmModule-800E

EmModule-800E Intel Ultra Low Voltage Celeron M 600MHz CPU 1 x 200-pin DDR SO-DIMM 200/266MHz up to 1GB Support CRT and LCD Intel 82562ET 10/100 Base-T Ethernet 4 x USB Ports, 2 x Serial Ports PC/104 and PC/104 ...

Leia mais

Cabela`s 55 Tournament

Cabela`s 55 Tournament BRACKET & HINGE ASSEMBLY

Leia mais