GLC012 to GLC500
Transcrição
GLC012 to GLC500
Load Link GLC012 to GLC500 Wireless Underhook Load Link Features Standard single part line pull sizes ranging from 12 500 to 500 000 kg All Aluminum frame and hardware Heavy duty construction – 2014/A Grade Accuracy of +/-1% of the WLL Ships Pre-calibrated Lightweight for easier portability Unique design ensures that load shackles used are always equal to the Max rating - WLL of the Load Link Radio range with line of sight: 4000 ft. (1300 m) Operates with one 'D' cell battery lithium 3.6V or alkaline 1.5V. Up to 2 years battery life. ISM license free radio; wavelength and modulation optimized for radio communication in industrial environments. Temperature range: -35°C to 60°C (-31°F to 140°F) Potted electronics for increased water protection Rugged field-replaceable antenna Custom sizes on request 2 year warranty Designed with a safety factor of 5:1 on the working load limit All units proof loaded to 150% of capacity. Applications Designed for all applications in the lifting industry, including offshore, that do not require the load cell to be submerged (due to radio communications). Installation is typically under the hook (vertical) and otherwise used horizontal for measure winch/rope and ground based pulling applications. Wireless Underhook Load Link General Description The load cell is installed in-line using two equally rated load shackles. This load creates minute deformations of the load link and electronics convert it into a load value, which is transmitted to the receiving unit. The radio transmitter, load convertor and battery are mounted inside the load link offering a low-profile design reducing the effect that impact has on the unit. LSI Rev.1.3 Page 1 of 5 Load Link GLC012 to GLC500 Table of Contents Features ................................................................................................................................................ 1 Applications ......................................................................................................................................... 1 General Description ............................................................................................................................. 1 Table of Contents ................................................................................................................................. 2 Specifications ....................................................................................................................................... 4 Absolute Maximum Ratings ................................................................................................................ 4 Certifications ........................................................................................................................................ 4 Materials............................................................................................................................................... 4 Dimensions........................................................................................................................................... 5 LSI Rev.1.3 Page 2 of 5 Load Link GLC012 to GLC500 Ordering Information North American FCC Standard Model GLC012-01 GLC025-01 GLC050-01 GLC075-01 GLC100-01 GLC150-01 GLC200-01 GLC250-01 GLC300-01 GLC400-01 GLC500-01 GS550-25 Description 12 500 kg WLL Underhook Load Link ( 902-928 MHz ) 25 000 kg WLL Underhook Load Link ( 902-928 MHz ) 50 000 kg WLL Underhook Load Link ( 902-928 MHz ) 75 000 kg WLL Underhook Load Link ( 902-928 MHz ) 100 000 kg WLL Underhook Load Link ( 902-928 MHz ) 150 000 kg WLL Underhook Load Link ( 902-928 MHz ) 200 000 kg WLL Underhook Load Link ( 902-928 MHz ) 250 000 kg WLL Underhook Load Link ( 902-928 MHz ) 300 000 kg WLL Underhook Load Link ( 902-928 MHz ) 400 000 kg WLL Underhook Load Link ( 902-928 MHz ) 500 000 kg WLL Underhook Load Link ( 902-928 MHz ) Under Hook Hand-Held Remote Wireless Display/Receiver - FCC (902-928 MHz) European CE standard Model GLC012-02 GLC025-02 GLC050-02 GLC075-02 GLC100-02 GLC150-02 GLC200-02 GLC250-02 GLC300-02 GLC400-02 GLC500-02 GS550-26 LSI Description 12 500 kg WLL Underhook Load Link ( 868-870 MHz ) 25 000 kg WLL Underhook Load Link ( 868-870 MHz ) 50 000 kg WLL Underhook Load Link ( 868-870 MHz ) 75 000 kg WLL Underhook Load Link ( 868-870 MHz ) 100 000 kg WLL Underhook Load Link ( 868-870 MHz ) 150 000 kg WLL Underhook Load Link ( 868-870 MHz ) 200 000 kg WLL Underhook Load Link ( 868-870 MHz ) 250 000 kg WLL Underhook Load Link ( 868-870 MHz ) 300 000 kg WLL Underhook Load Link ( 868-870 MHz ) 400 000 kg WLL Underhook Load Link ( 868-870 MHz ) 500 000 kg WLL Underhook Load Link ( 868-870 MHz ) Under Hook Hand-Held Remote Wireless Display/Receiver - CE (868-870 MHz) Rev.1.3 Page 3 of 5 Load Link GLC012 to GLC500 Specifications Parameter Load Tension Measurement Resolution Accuracy Repeatability Radio Power Radio Frequency North American version European version Battery life Test Condition Min Typ Max +/- @21°C +/- @21°C +/- @21°C 0.025 0.1 0.05 0.075 0.5 0.25 0.2 1 0.5 GLCXXX-XX 0.013 11 0.016 12 0.020 13 W dBm GLCXXX-01 GLCXXX-02 902 868 928 870 MHz MHz 24 16 Month Month ‘D’ cell lithium ‘D’ cell alkaline 18 6 Unit % of WLL % of WLL % of WLL Absolute Maximum Ratings Parameter Ambient temperature range Test Condition Operating Storage Min -35 -31 -35 -31 Typ Max +60 +140 +65 +140 Certifications Safety IEC 61010-1 Radio/EMC FCC : parts 15.247, 15.205, 15.207 Industry Canada : RSS-210 CE : EN 300 220-3, EN 301 489-3 Materials The load cell is made of aluminum L168 2014A – T6511 with aluminum battery caps. LSI Rev.1.3 Page 4 of 5 Unit ºC ºF ºC ºF Load Link GLC012 to GLC500 Dimensions Max Load Model number GLC012 GLC025 GLC050 GLC075 GLC100 GLC150 GLC200 GLC250 GLC300 GLC400 GLC500 LSI A B C D EØ Unit Weight (in) 4.92 13.90 2.52 9.84 1.57 27557 lb (mm) 125 353 64 250 40 12500 kg 2.3 lb 5 kg (in) 5.08 15.35 2.52 9.84 2.17 55115 lb 11 lb (mm) 129 390 64 250 55 25000 kg 7 kg (in) 6.14 18.58 3.15 11.81 2.95 110231 lb 27 lb (mm) 156 472 80 300 75 50000 kg 13 kg (in) 6.54 19.37 3.86 11.81 3.35 165346 lb 38 lb (mm) 166 492 98 300 85 75000 kg 17 kg (in) 7.72 23.62 4.72 15.75 3.94 220462 lb 71 lb (mm) 196 600 120 400 100 100000 kg 32 kg (in) 10.24 25.98 5.51 15.75 4.72 330693 lb 117 lb 150000 kg 53 kg 157 lb (mm) 260 660 140 400 120 (in) 11.73 28.50 5.91 16.69 5.24 440924 lb (mm) 298 724 150 424 133 200000 kg 72 kg (in) 13.70 32.44 5.91 18.66 5.67 551155 lb 210 lb (mm) 348 824 150 474 144 250000 kg 95 kg (in) 16.14 36.02 5.91 20.28 6.30 661386 lb 275 lb (mm) 410 915 150 515 160 300000 kg 125 kg (in) 17.32 40.31 7.87 22.60 7.09 881849 lb 426 lb (mm) 440 1024 200 574 180 400000 kg 198 kg (in) 19.69 42.68 7.87 23.46 7.48 1102311 lb 528 lb (mm) 500 1084 200 596 190 500000 kg 240 kg Rev.1.3 Page 5 of 5
Documentos relacionados
University of Mumbai
Principals of the affiliated colleges, Heads of the Recognised institutions , Professor-cumDirector, Institute of Distance & Open Learning (IDOL) and the Assistant Registrars, University Sub-Centre...
Leia maisEmModule-800E
Intel Ultra Low Voltage Celeron M 600MHz CPU 1 x 200-pin DDR SO-DIMM 200/266MHz up to 1GB Support CRT and LCD Intel 82562ET 10/100 Base-T Ethernet 4 x USB Ports, 2 x Serial Ports PC/104 and PC/104 ...
Leia mais