B3-REL16E - Augeo.com.br
Transcrição
B3-REL16E - Augeo.com.br
Data sheet ____________________________________________________________________________________________________________________ SecuriFire B3-REL16E Relay board with 24 V contacts The B3-REL16E board contains 16 bistable 24 V / 3 A relays. Each relay output can be used as a VdS-compliant extinguishing interface in connection with an input on the B3-IM8. Fig. 1 B3-REL16E Domain: SCP3000 ____________________________________________________________________________________________________________________ Function/Application Plug for relays (X2) and (X3) The B3-REL16E has 16 freely programmable bistable 24V / 3A relays for connecting fire incident controls. Defining whether the contact is a working or normally closed contact is done with planning software. Further, for each relay a “FailSafe-Position” can be defined for instances in which there is a power failure or the SCP is switched off. Plug X2 Designation Relay R16 Relay R15 he connection to the B5-BAF / B5-MRI16 is on the rear side using a 32-pin male connector via relay BUS. The peripheral devices are connected on the front side of the board with two 16-pin plug-in terminals. Relay R14 Interfaces Relay R13 X1 Connection to the relay BUS X2 Connector plug for relays 9-16 (24V / 3A) X3 Connector plug for relays 1-8 BR1-16 Relay R12 (24V / 3A) Jumper for setting operation mode “Relay contact” or “VdS-compliant interface” Relay R11 Relay R10 Relay R9 Plug X3 Terminal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Designation Terminal 1 Relay R8 2 3 Relay R7 4 5 Relay R6 6 7 Relay R5 8 9 Relay R4 10 11 Relay R3 12 13 Relay R2 14 15 Relay R1 16 Technical data X2 und X3 Relay design bistable Switching voltage max. 30 V AC / 30 V DC Switching current max. 3 A Breaking capacity max. 60W (2 A at 30 V) Contact protection Small 3.15 A fuse with slow-acting triggering Contact resistance max. 30 mΩ 2 Mechanical plug-in screw terminal, max. 2.5 mm Jumper settings With jumpers BR1 to BR16 you select “Relay output” or VdScompliant “Extinguishing” standard interface. Fig. 2 B3-REL16E interfaces Securiton AG Alpenstrasse 20 3052 Zollikofen Switzerland 4 2 4 2 3 1 3 1 Relay output “Extinguishing” standard interface T 811108 en d 1/3 Data sheet Planning The country-specific directives apply when planning and installing automatic fire detector systems. When connecting inductive loads, it is recommended to use a freewheel diode (e.g. 1N4007). The B3-REL16E can be fitted in the unit rack of each SecuriFire 3000 at slots 11 to 13 of the unit rack. However, a B5-BAF or B5MRI16 board must be fitted to slot 9. B3-REL16E X3 ... ... R4 R4 R3 R3 R2 R2 R1 R1 Defining whether the contact is a working or normally closed contact is done with planning software SecuriFire Studio. By programming an “Active in Fail-Safe-Position”, the state of each individual relay can be defined for power supply failure or shut down of the SCP. These are additionally fused for using the relay as a standard extinguishing interface, and the alarm resistors (680 Ω) and monitoring resistors (3.3 kΩ) are already installed. Additionally, two inputs also have to be planned on the B3-IM8. Holding magnet + _ 4 2 3 1 The B3-REL16E is supported beginning with SecuriFire Studio R 1.0. B5-PSU Connection examples X5 Vext GND B3-REL16E X3 ... ... R4 R4 R3 R3 R2 R2 R1 R1 Siren + Fig. 4 Connecting normally closed contact 4 2 3 1 B5-PSU X5 Vext GND Fig. 3 Connecting working contact 2/3 T 811108 en d B3-REL16E Data sheet Interface compliant with VDE 0833-2 and VdS 2496 standards for connecting a fire alarm control panel to an electric control unit. In the command direction, this is comprised of any output with monitoring resistors (already included in the B3-REL16E). In the alarm direction, this is comprised of two monitored inputs (B3-IM8). The “Extinguishing” standard interface is NOT for directly actuating an extinguishing system! The SecuriFire 3000 can be used either as a fire alarm control panel or electrical control unit. B3-REL16E X3 (or X2) Fault in extinguishing system SST 3 1 B3-IM8 1 2 3 680R 3k3 4 2 X13 3 1 Fault in extinguishing system Extinguishing system triggered B3-IM8 SST 1 2 3 X13 C L Extinguishing system triggered 4 2 FACP C L 3k3 3k3 680R Extinguish command R4 R4 R3 R3 R2 R2 R1 R1 680R EST X3 (or X2) ... ... ... ... R4 R4 R3 R3 R2 R2 R1 R1 B3-REL16E Extinguish command C L max. 1000m max. 1000m Fig. 5 SecuriFire 3000 as fire alarm control panel Fig. 6 SecuriFire 3000 as control unit Article numbers / spare parts Short designation B3-REL16E ST-SET REL16 ST-SET REL16 W Relay board with 24 V contacts (incl. ST-SET REL16) 2 pcs. plug straight (frontal screwable) 2 pcs. plug angled Art. number CH 115.979 066 239.972 312 239.239 690 Art. number 20-1000005-01-01 20-1040100-01-01 FG74105 Technical data provided by the unit at slot 9 via the relay BUS according to control panel according to control panel 440/315 g Power supply Protection type Ambient temperature, Relative humidity, Air pressure Weight (gross/net) B3-REL16E T 811108 en d, 20.08.2015 Rd First edition: 27.08.2010 Rd The product specifications contained in this document are subject to change without notice. © Copyright by Securiton 3/3
Documentos relacionados
Modulo reles GFE-MPX-REL
There is also a LED indication of ALARM condition for each individual zone. The LED RED indicator will be ON when the relay is active. These relay outputs are not monitored. The d.i.l switch allows...
Leia mais