Stadia CT Varzea Grande Project code: Date: 00298Q01 02-12-2010 Designer: Eng Adriano Genistretti The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixed relationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminaire positioning, reflection properties and electrical supply. Philips do Brasil Ltda Rua Verbo Divino 1400 - 6. andar Chácara Santo Antonio CEP 04719-002 São Paulo - SP Telephone: 55 11 2125-0781 E-Mail: [email protected] CalcuLuX Area 7.5.0.1 Stadia 00298Q01 Philips do Brasil Ltda Date: 02-12-2010 CT Varzea Grande 1. Project Description 1.1 3-D Project Overview B A BB BB BB B BB BB B B BB B B B B B B B B B B B B B B A Y Z X A SLS 1500-128 Philips Lighting B.V. - CalcuLuX Area 7.5.0.1 B SLS 1500-158 Page: 2/9 Stadia 00298Q01 Philips do Brasil Ltda Date: 02-12-2010 CT Varzea Grande 60 70 80 1.2 Top Project Overview 50 B B 40 B B B 30 B B A B B 20 B B 10 B B B 0 Y(m) B B B -10 B B -20 B B B -30 B B A B B -40 B B -50 B -80 -70 -60 B -65 -55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 X(m) A SLS 1500-128 B SLS 1500-158 Scale 1:750 Philips Lighting B.V. - CalcuLuX Area 7.5.0.1 Page: 3/9 Stadia 00298Q01 Philips do Brasil Ltda Date: 02-12-2010 CT Varzea Grande 2. Summary 2.1 General Information The overall maintenance factor used for this project is 0.80. 2.2 Obstacle Information Obstacle Transparency (%) Block Pillar X (m) -60.00 60.00 60.00 100 100 Position Y (m) -52.50 31.00 -31.00 Z (m) 0.00 0.00 0.00 2.3 Project Luminaires Code A B Qty Luminaire Type 40 SLS 1500-128 34 SLS 1500-158 Lamp Type 1 * MH 1500 1 * MH 1500 Power (W) 1610.0 1610.0 Flux (lm) 1 * 155000 1 * 155000 The total installed power: 119.14 (kWatt) Number of Luminaires Per Arrangement: Luminaire Code Arrangement A B Line 0 28 Point 40 6 Power (kWatt) 45.08 74.06 2.4 Calculation Results (Il)luminance Calculations: Calculation Type Football Surface Illuminance Glare Rating for Grid of Observers: Calculation Observer Grid Glare Football Philips Lighting B.V. - CalcuLuX Area 7.5.0.1 Unit lux Ave 513 Reference Grid Football Min 333 Max Min/Ave Min/Max 683 0.65 0.49 Reflectance 0.25 GR-Max 49.3 Page: 4/9 Stadia 00298Q01 Philips do Brasil Ltda Date: 02-12-2010 CT Varzea Grande 3. Calculation Results 3.1 Football: Graphical Table : Football at Z = -0.00 m : Surface Illuminance (lux) 55 65 75 Grid Calculation B 45 B B 378 440 438 404 403 418 437 433 406 396 432 540 491 641 383 484 506 494 484 478 502 533 525 564 566 479 454 437 354 503 545 533 518 509 509 508 509 512 497 443 398 344 B 35 B B 25 B 344 500 559 544 522 507 509 511 529 541 481 426 388 333 345 511 578 566 548 531 510 505 528 550 500 466 494 466 A B 356 523 596 596 587 571 543 527 523 520 508 524 666 600 B B 15 B B 364 536 610 611 605 591 564 560 610 632 594 549 503 402 368 541 617 613 598 575 553 556 583 632 683 566 455 348 370 538 614 613 604 582 560 569 579 586 581 530 456 353 B 5 B Y(m) B -5 B 359 529 611 604 588 577 593 598 574 575 534 441 486 437 348 523 605 588 575 579 621 634 569 516 438 384 423 511 359 529 611 604 588 577 593 598 574 575 534 441 486 437 B B -15 B B 370 538 614 613 604 582 560 569 579 586 581 530 456 353 368 541 617 613 598 575 553 556 583 632 683 566 455 348 364 536 610 611 605 591 564 560 610 632 594 549 503 402 B -25 B B -35 B 356 523 596 596 587 571 543 527 523 520 508 524 666 600 345 511 578 566 548 531 510 505 528 550 500 466 494 466 A B 344 500 559 544 522 507 509 511 529 541 481 426 388 333 B B -45 B B 354 503 545 533 518 509 509 508 509 512 497 443 398 344 383 484 506 494 484 478 502 533 525 564 566 479 454 437 378 440 438 404 403 418 437 433 406 396 432 540 491 641 -75 -65 -55 B -65 -55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 X(m) A Average 513 SLS 1500-128 Minimum 333 Maximum 683 Philips Lighting B.V. - CalcuLuX Area 7.5.0.1 B Min/Ave 0.65 SLS 1500-158 Min/Max 0.49 Project maintenance factor 0.80 Scale 1:750 Page: 5/9 Stadia 00298Q01 Philips do Brasil Ltda Date: 02-12-2010 CT Varzea Grande 3.2 Glare: Graphical Table : : : : Football Glare Rating Football (Reflectance: 0.25) 0.0 deg 55 65 75 Grid of Observers Calculation Grid for Background Luminance Vertical Viewing Angle B 43 45 46 47 49 49 49 4742 4442 43 43 43 B 43 44 46 48 49 49 49 49 4743 4644 44 44 B 42 43 44 46 47 48 48 44 44 47 45 44 44 44 B 42 43 44 45 46 47 47 46 45 45 45 45 45 45 43 44 45 46 47 47 4745 46 45 46 46 45 45 43 44 45 35 45 B B A B 25 B 15 B 47 48 48 4746 46 46 46 46 46 46 47 48 49 48 47 47 46 46 46 46 46 47 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 B 43 44 45 B 43 45 46 47 48 49 48 43 45 46 47 48 48 48 43 44 45 46 46 B 42 43 43 44 45 43 44 45 46 46 47 43 45 46 47 48 48 47 46 46 46 46 47 47 46 46 45 46 46 46 47 46 46 47 47 46 46 46 48 47 46 43 45 46 47 48 49 48 46 46 47 46 46 46 46 B B 43 44 45 47 48 49 48 46 46 47 47 46 46 46 B 43 44 45 47 48 48 4746 46 46 46 46 46 46 43 44 45 46 47 47 4745 46 45 46 46 45 45 B 42 43 44 45 46 47 47 46 45 45 45 45 45 45 B 42 43 44 46 47 48 48 47 45 44 44 44 44 44 B 43 44 46 48 49 49 49 49 4743 4644 44 44 43 45 46 47 49 49 49 4742 4442 43 43 B 5 B Y(m) B 47 45 -5 B B B -25 -15 B B A B -45 -35 B B 43 -75 -65 -55 B -65 -55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 X(m) A SLS 1500-128 Maximum 49.3 Philips Lighting B.V. - CalcuLuX Area 7.5.0.1 B SLS 1500-158 Project maintenance factor 0.80 Scale 1:750 Page: 6/9 Stadia 00298Q01 Philips do Brasil Ltda Date: 02-12-2010 CT Varzea Grande 4. Luminaire Details 4.1 Project Luminaires Luminous Intensity Diagram (candela/1000 lumen) 120o 150o 180o 150o 120o SLS 1500-128 1xMH 1500 Light output ratios DLOR ULOR TLOR Lamp flux Luminaire wattage : : : : : 0.74 0.00 0.74 155000 lm 1610.0 W 90o 90o 60o 60o Note: Luminaire data not from database. 7500 30o 0o Imax 30o C = 0o C = 90o Luminous Intensity Diagram (candela/1000 lumen) 120o 150o 180o 150o 120o SLS 1500-158 1xMH 1500 Light output ratios DLOR ULOR TLOR Lamp flux Luminaire wattage C = 180o C = 270o : : : : : 0.74 0.00 0.74 155000 lm 1610.0 W 90o 90o 60o 60o Note: Luminaire data not from database. 1000 30o Philips Lighting B.V. - CalcuLuX Area 7.5.0.1 C = 180o C = 270o 0o Imax 30o C = 0o C = 90o Page: 7/9 Stadia 00298Q01 Philips do Brasil Ltda Date: 02-12-2010 CT Varzea Grande 5. Installation Data 5.1 Legends Project Luminaires: Code Qty Luminaire Type A 40 SLS 1500-128 B 34 SLS 1500-158 Lamp Type 1 * MH 1500 1 * MH 1500 Flux (lm) 1 * 155000 1 * 155000 5.2 Luminaire Positioning and Orientation Qty and Code Position Aiming Points Aiming Angles X (m) Y (m) Z (m) X (m) Y (m) Z (m) Rot. Tilt90 Tilt0 1*B 1*B 1*B 1*B 1*B -42.50 -42.50 -42.50 -42.50 -42.50 -50.63 -46.88 -43.13 -39.38 -35.63 17.00 17.00 17.00 17.00 17.00 -24.31 17.99 -11.23 14.28 -11.01 -50.58 -47.53 -42.73 -40.12 -35.54 -0.00 -0.00 -0.00 -0.00 -0.00 0.2 -0.6 0.7 -0.7 0.2 46.9 74.3 61.5 73.3 61.6 0.0 0.0 0.0 0.0 0.0 1*B 1*B 1*B 1*B 1*B -42.50 -42.50 -42.50 -42.50 -42.50 -31.88 -28.13 -24.38 -20.63 -16.88 17.00 17.00 17.00 17.00 17.00 11.66 -7.96 12.32 -10.36 9.05 -32.05 -27.91 -24.86 -21.80 -17.88 -0.00 -0.00 -0.00 -0.00 -0.00 -0.2 0.4 -0.5 -2.1 -1.1 72.6 63.8 72.8 62.1 71.8 0.0 0.0 0.0 0.0 0.0 1*B 1*B 1*B 1*B 1*B -42.50 -42.50 -42.50 -42.50 -42.50 -13.13 -9.38 -5.63 -1.88 1.88 17.00 17.00 17.00 17.00 17.00 -10.14 9.48 -9.49 3.60 3.60 -13.08 -9.81 -6.32 -2.62 2.62 -0.00 -0.00 -0.00 -0.00 -0.00 0.1 -0.5 -1.2 -0.9 0.9 62.3 71.9 62.8 69.8 69.8 0.0 0.0 0.0 0.0 0.0 1*B 1*B 1*B 1*B 1*B -42.50 -42.50 -42.50 -42.50 -42.50 5.63 9.38 13.13 16.88 20.63 17.00 17.00 17.00 17.00 17.00 -9.49 9.48 -10.14 9.05 -10.36 6.32 9.81 13.08 17.88 21.80 -0.00 -0.00 -0.00 -0.00 -0.00 1.2 0.5 -0.1 1.1 2.1 62.8 71.9 62.3 71.8 62.1 0.0 0.0 0.0 0.0 0.0 1*B 1*B 1*B 1*B 1*B -42.50 -42.50 -42.50 -42.50 -42.50 24.38 28.13 31.88 35.63 39.38 17.00 17.00 17.00 17.00 17.00 12.32 -7.96 11.66 -11.01 14.28 24.86 27.91 32.05 35.54 40.12 -0.00 -0.00 -0.00 -0.00 -0.00 0.5 -0.4 0.2 -0.2 0.7 72.8 63.8 72.6 61.6 73.3 0.0 0.0 0.0 0.0 0.0 1*B 1*B 1*B 1*A 1*A -42.50 -42.50 -42.50 60.00 60.00 43.13 46.88 50.63 -31.00 -31.00 17.00 17.00 17.00 30.00 30.00 -11.23 17.99 -24.31 0.00 -4.91 42.73 47.53 50.58 0.00 -37.28 -0.00 -0.00 -0.00 0.00 -0.00 -0.7 0.6 -0.2 152.7 -174.5 61.5 74.3 46.9 66.0 65.3 0.0 0.0 0.0 0.0 0.0 1*A 1*A 1*A 1*B 1*A 60.00 60.00 60.00 60.00 60.00 -31.00 -31.00 -31.00 -31.00 -31.00 30.00 30.00 30.00 30.00 30.00 16.02 15.15 31.94 26.49 29.54 -15.04 -5.67 -50.58 -51.02 -26.16 -0.00 -0.00 -0.00 -0.00 -0.00 160.1 150.5 -145.1 -149.1 171.0 57.3 59.8 48.8 52.5 45.8 0.0 0.0 0.0 0.0 0.0 1*A 1*B 1*A 1*A 1*A 60.00 60.00 60.00 60.00 60.00 -31.00 -31.00 -31.00 -31.00 -31.00 30.00 30.00 30.00 30.00 30.00 -13.86 -11.24 -9.72 21.46 -10.59 -43.39 -30.96 -22.24 -50.58 -10.03 -0.00 -0.00 -0.00 -0.00 -0.00 -170.5 180.0 172.8 -153.1 163.5 68.2 67.2 66.9 55.2 67.8 0.0 0.0 0.0 0.0 0.0 1*A 1*A 60.00 60.00 -31.00 -31.00 30.00 30.00 28.95 1.18 5.21 -6.76 -0.00 -0.00 130.6 157.6 57.8 64.8 0.0 0.0 Philips Lighting B.V. - CalcuLuX Area 7.5.0.1 Page: 8/9 Stadia 00298Q01 Qty and Code Philips do Brasil Ltda Date: 02-12-2010 CT Varzea Grande Position Aiming Points Aiming Angles X (m) Y (m) Z (m) X (m) Y (m) Z (m) Rot. Tilt90 Tilt0 1*A 1*A 1*A 60.00 60.00 60.00 -31.00 -31.00 -31.00 30.00 30.00 30.00 -9.72 -1.87 -10.15 -27.91 -51.89 -49.93 -0.00 -0.00 -0.00 177.5 -161.3 -164.9 66.7 65.3 67.6 0.0 0.0 0.0 1*A 1*B 1*A 1*A 1*A 60.00 60.00 60.00 60.00 60.00 -31.00 -31.00 -31.00 -31.00 -31.00 30.00 30.00 30.00 30.00 30.00 -10.37 16.39 0.74 8.94 11.17 -17.44 -4.10 -45.06 -19.19 -32.40 -0.00 -0.00 -0.00 -0.00 -0.00 169.1 148.3 -166.7 167.0 -178.4 67.3 59.7 63.8 60.2 58.4 0.0 0.0 0.0 0.0 0.0 1*A 1*A 1*A 1*A 1*A 60.00 60.00 60.00 60.00 60.00 -31.00 31.00 31.00 31.00 31.00 30.00 30.00 30.00 30.00 30.00 14.90 0.00 -4.91 16.02 15.15 -44.69 0.00 37.28 15.04 5.67 -0.00 0.00 -0.00 -0.00 -0.00 -163.1 -152.7 174.5 -160.1 -150.5 57.5 66.0 65.3 57.3 59.8 0.0 0.0 0.0 0.0 0.0 1*A 1*B 1*A 1*A 1*B 60.00 60.00 60.00 60.00 60.00 31.00 31.00 31.00 31.00 31.00 30.00 30.00 30.00 30.00 30.00 31.94 26.49 29.54 -13.86 -11.24 50.58 51.02 26.16 43.39 30.96 -0.00 -0.00 -0.00 -0.00 -0.00 145.1 149.1 -171.0 170.5 -180.0 48.8 52.5 45.8 68.2 67.2 0.0 0.0 0.0 0.0 0.0 1*A 1*A 1*A 1*A 1*A 60.00 60.00 60.00 60.00 60.00 31.00 31.00 31.00 31.00 31.00 30.00 30.00 30.00 30.00 30.00 -9.72 21.46 -10.59 28.95 1.18 22.24 50.58 10.03 -5.21 6.76 -0.00 -0.00 -0.00 -0.00 -0.00 -172.8 153.1 -163.5 -130.6 -157.6 66.9 55.2 67.8 57.8 64.8 0.0 0.0 0.0 0.0 0.0 1*A 1*A 1*A 1*A 1*B 60.00 60.00 60.00 60.00 60.00 31.00 31.00 31.00 31.00 31.00 30.00 30.00 30.00 30.00 30.00 -9.72 -1.87 -10.15 -10.37 16.39 27.91 51.89 49.93 17.44 4.10 -0.00 -0.00 -0.00 -0.00 -0.00 -177.5 161.3 164.9 -169.1 -148.3 66.7 65.3 67.6 67.3 59.7 0.0 0.0 0.0 0.0 0.0 1*A 1*A 1*A 1*A 60.00 60.00 60.00 60.00 31.00 31.00 31.00 31.00 30.00 30.00 30.00 30.00 0.74 8.94 11.17 14.90 45.06 19.19 32.40 44.69 -0.00 -0.00 -0.00 -0.00 166.7 -167.0 178.4 163.1 63.8 60.2 58.4 57.5 0.0 0.0 0.0 0.0 Philips Lighting B.V. - CalcuLuX Area 7.5.0.1 Page: 9/9
Documentos relacionados
55-9459-Z5-M3 - Leds-C4
Emitting area on Plane 180° Emitting area on Plane 270° Glare area at 76°
Leia mais15-9677-14-M1 - Leds-C4
Horizontal Luminous Area Emitting area on Plane 0° Emitting area on Plane 90°
Leia mais