Clima package
Transcrição
Thermotech Underfloor Heating System Clima package Product ID: 37003 Advantages • More convenient as the indoor temperature will be more even • Optimal driftsekonomi Area of use Why compensate for outdoor temperature? All Thermotech’s mixing unit’s can be equipped with a heating controller that takes the outdoor temperature into consideration, and compensates for any variations in the outdoor temperature. Waterborne underfloor heating systems operate with low flow temperatures compared to radiators and are therefore often called “low temperature systems”. Product specification The Clima equipment is a compact heating controller for PI-control of the flow temperature controlled by the outdoor temperature. The heating controller has various functions, such as: The water temperature in underfloor heating systems is generally, during the hot seasons, lower than in a corresponding radiator system. For that reason, a unit that controls the flow temperature taking the outdoor temperature into account is needed for optimal operational efficiency and convenience. • Min/max limiter of the flow and return temperature • Function test of circulation pump and valve The Clima package consists of the following components: • 1 motor (24 VAC) • 1 heating controller with curve-settings • 1 outdoor temperature sensor • 1 flow temperature sensor • 1 transformer for wall-socket 230/24V Phone: +46 (0)620 68 33 30, www.thermotech.eu Thermotech Scandinavia AB fulfils the ISO standards for quality- and environment management. IG506-1411 Thermotech Company Group Certifierad ISO 9001 ISO 14001 1 (4) 137 Thermotech Underfloor Heating System Installation guide Mounting of the control equipment 1. De-mount the cover from the control unit and mount its back-plate in the desired place. 2. Mount the outdoor temperature sensors on the buildings north or north-west wall. Use 2 x 0.5 mm cords between the sensor and the control unit and connect the cords to socket 10 and 11. The polarity does not matter. Thermotech Clima package Service mode settings The unit has to be in service mode to set the heat curve, max and min flow temperature and other parameters. Please follow these instructions to access service mode: mode: 3. Mount the flow temperature sensor on the feed pipe and connect it to socket 9 and 10. The polarity does not matter. The cable can be extended if needed. 4. Mount actuators on the 2- or 3-way valve and connect the valve’s cable to the regulator. Connect the blue wire to contact 2, white to contact 3 and the red to contact 4. 5. If pump control is needed, the circulation pump is connected to the control unit. Connect the phase for the pump to socket 5 and 6 (potential-free relay). Display and adjust parameters in the service mode Different parameters have different codes, from P01 to P60. Please follow these instructions to display/adjust parameters; 6. Connect the transformer cable to socket 1 and 2. The polarity does not matter. Re-mount the control units cover and connect the transformer to the wall socket. Basic settings When the system is powered for the first time you have 2 minutes to set time, date and language. It is possible to change these settings later (please view the instructions below). Choose language All the parameters do not need to be set to adjust the unit for underfloor heating. Most of settings are already correct by default. The following parameters have to be adjusted; P06: Control model Select 1, for flow temperature controlled by the outdoor temperature. Setting the date and time P09: Display of current temperature Select 2, to display the flow temperature on the monitor. P22: Valve run time Select 60, for a run time suitable for 24V AXM 117 actuators. P23: Min. limiting of flow temperature Select 28°C, or the wanted temperature. Press ‘ESC’ to return to automatic mode. P24: Max. limiting of the flow temperature Select 45°C, or the dimensioned flow temperature that has been acknowledged for the system. 2 (4) 138 Thermotech Underfloor Heating System Installation guide Thermotech Clima package P29: Heat curve Curves ranging from 0.4 to 0.6 are recommended depending on the floor construction (please view the image below). • 0.4 is suitable for screed constructions. • 0.6 is suitable for wooden constructions where aluminium plates are used as heat transfer medium. Heat curve Flow temperature Curve Outdoor temperature Please view the complete manual included in the delivery for more detailed information about functions and settings of parameters. If CCC appears in the display, there has been a short in the circuit for the displayed value. The flow temperature is shown by default. Error indications A line at the top of the display – the value is too large to be displayed. The flow temperature is shown by default. If an error occurs it will be shown in the display. The letter combination ERR will be visible and the status for the unit can requested in the service mode (please view the detailed manual for further information). If a breakage in the cables is detected the letter combination UUU will be displayed for the displayed value. The flow temperature is shown by default. A line at the bottom of the display – the value is too small to be displayed. The flow temperature is shown by default. Please view the limit value in the detailed manual that comes with the control unit. 3(4) 139 Thermotech Underfloor Heating System Installation guide Thermotech Clima package circuit diagram 37004 Black Blue Blå Red Brown Svart Orange 37008 Black Brun 37007 37006 37005 67006 We reserve the right to change products without notice. We refer you to www.thermotech.eu for the latest version of the installation instructions. No liability is accepted for any typographical errors. 4 (4) 140
Documentos relacionados
Metro Atlantas Best Outdoor Venue and Private Retreat The Green Valley Ranch
Metro Atlanta's Best Outdoor Venue and Private Retreat | The Green Valley Ranch www.thegreenvalleyranch.com The Green Valley Ranch, led by CEO Ernest Flagg and Team TGVR, is proud to announce the official opening of Atlanta's newest exclusive, most natural outdoor venue and private retreat - The Courtyard at The Green Valley Ranch. The Green Valley Ranch
Leia maisWellnes Center Sun Garden Hotel
aesthetically is the perfect solution. Together with Uponor radiant heating system was installed room temperature control system which helped to reduce the amount of energy with 12%. DEM radio syst...
Leia maisservicegenius.com-Air conditioning repair Service Genius Air Conditioning and Heating
Service Genius https://servicegenius.com Service Genius air conditioning and heating services the heating and cooling needs of the North and West neighborhoods of Los Angeles #AirconditioningandHeatingrepairservice
Leia mais