Aspectos fisicos de SRS Intra craneal y SBRT en Columna Aluísio Castro Físico Médico Especialista em Radioterapia Centro de Oncologia D´Or - Rio de Janeiro - Brasil Agenda • • • • • • Patient Immobilization Imaging Treatment Planning Patient/Target Localization Treatment Delivery QA P.S. Focus on Exactrac System Patient Immobilization Cranial • Invasive Frame based – Rigid – Invasive – No fractionation allowed • Frameless systems – Mask system – Allows some interfraction differences – Image guided patient localization Patient Immobilization Spine • Invasive Frame based – Invasive – No fractionation allowed • Noninvasive body frame – Lack of rigid fixation to vertebral column Patient Immobilization Spine • Frameless systems – Image guided target localization – Monitoring for patient movement – Customized cradle and vacuum bag • Some immobilization • Patient stabilization • Patient confort – Mask systems • Cervical and upper thoracic (T1-T3) Imaging • Imaging Modalities – CT is mandatory for treatment planning • Geometric target localization • Electron density information for heterogeneity correction during UM calculation • Slices < 3mm for DRR accuracy – MRI is essential for a good target delineation • Soft tissue contrast • High spatial resolution is required (<1mm slice) Imaging: Registration MRI x CT Imaging: Registration • Volume of interest Imaging: Registration • Volume of interest Imaging: Registration • Volume of interest Imaging: Registration • Volume of interest Imaging • Registration issues – Artifacts – Body articulation Tretatment Planning • Aims: – Comform radiation dose to the target – Rapid dose fall-off – OAR sparing • Large number of beams (static techniques) – Conformal or IMRT • Volumetric techniques – Hybric Arc, RadipArc, VMAT Tretatment Planning • Dose calculation algorithms: – Pencil Beam works fine in homogeneous regions like brains but tends to overstimate target coverage in presence of inhomogeneities – MC is the algorithm of choice for areas with density heterogeneity as spine surroundings Tretatment Planning • Dose calculation algorithms: – Pencil Beam works fine in homogeneous regions like brains but tends to overstimate target coverage in presence of inhomogeneities – MC is the algorithm of choice for areas with density heterogeneity as spine surroundings Localization • 2D Radiography – EPID (MV) – KV (machine-mounted or room-mounted) – Bony anatomy • CBCT (MV or KV) – Bony and soft tissue anatomy – Not allowed with couch ≠ 0º. Localization • Bony anatomy • Soft tissue • Fiducials Localization • Bony anatomy • Fiducials • Neighbor-vertebra trick Localization • Bony anatomy • Fiducials • Neighbor-vertebra trick Localization tricks – 2D images Localization tricks – 2D images Exactrac – Infra Vermelho (IR) Exactrac – Infra Vermelho (IR) • Fonte de luz IR • Refletores IR fixos ao paciente • Duas câmeras IR • Posicionamento inicial do paciente • Monitoramento real-time do posicionamento Exactrac – Raios X (RX) • 2 tubos de RX • 2 detectores Flat Panel • Fusão com imagens de planejamento (DRRs) • Cálculo do deslocamento translacional e rotacional do paciente Exactrac – Mesa Robótica 6D • Movimentos de translação (lat., vert., long.) e rotação (pitch, roll e table) • Precisão submilimétrica e décimos de grau Quality assurance • • • • • • Patient specific Laser aligment Winstow-Lutz test Image Guidance Device Test Dosimetric tests Machine QA Quality assurance • Laser aligment to radiation isocenter Winston-Lutz Test Quality assurance • Laser and imaging isocenter aligment Quality assurance • InfraRed System calibration Quality assurance • RX System calibration Quality assurance - Other tests • Image Quality – Detector gain, dead pixel correction – X-ray generator performance • Gantry, collimator and couch isocenter • Dosimetric tests – Beam symmetry and flatness, PDDs, OFs • MLC • Beam calibration Quality assurance - Processes • Double check: – Image labels (name, id, etc...) – Target delineation, dose prescription (second opnion) – Planning (DVHs, MUs, dose distribution, collision risks, etc...) – Printouts, export and import of files, OIS – Treatment delivery (patient movements and machine performance) Summary • Patient Immobilization • Imaging and Target & OAR delineation – proper modality and registration • Planning – multiple fields / volumetric techniques – attention to the OAR limits of dose • Patient localization – image guidance • Delivery • QA systems and processes Gracias! [email protected]
Documentos relacionados
MAGNETOM C! - RP Medical
Advanced abdominal imaging with
syngo REVEAL diffusion imaging
in all body regions including liver.