Catalogue 2014 - Carrier Portugal
Transcrição
Catalogue 2014 - Carrier Portugal
Heating, ventilation and air conditioning solutions Catalogue 2014 Catalogue 2014 Index Alphanumeric and product section index .....................2 Addresses ....................................................................................4 Carrier - experience backed by a large group ..............6 Natural leadership - sustainability at Carrier ..............8 Building systems and solutions ...................................... 12 Aquasmart Evolution .......................................................... 14 Carrier Service ........................................................................ 18 30XW-V/30XWHV variable-speed water-cooled chillers and heat pumps .................................................... 20 Systems applications........................................................... 21 Products ................................................................................... 30 1 Contents - alphanumeric Series Page 09 09AD/FCAD 09AL/FCAL 09TE/FCTE 66 70 68 16 16DJ 16LJ 16NK 16TJ 152 146 150 148 19 19XR/XRV 144 23 23XR/XRV 64 30 30AWH 30HXC 30RB 008-015 30RB 017-033 30RB 162-802 30RBM/30RBP 30RBS 039-160 30RBSY 039-160 30RBY 017-033 30RQ 017-033 30RQ 182-522 30RQS 039-160 30RQSY 039-160 30RQY 017-033 30RW/RWA 30WG/30WGA 30XA 30XAS 30XAV 30XW 34 & 76 58 32 36 44 46 40 42 38 84 92 88 90 86 56 54 50 48 52 60 30XWH 30XW-V 30XWHV 96 62 98 Series Page 38 38AW/80AW 38RBS 74 132 39 39HQ 39MQ 39SQ 39SQC/R/P 126 128 122 124 42 42BJ 42DW 42EM 42GM 42GR 42GW 42N 112 110 108 114 116 104 106 48 48UA 48UH 140 140 50 50PZ 50TZ 50UA 50UH 50YZ 138 134 140 140 136 61 61AF 014-019 61AF 022-105 61WG 80 82 94 80 80HMA Control systems Aquasmart Evolution 78 162 Electronic fan coil 35 35BD/SR 118 36 36XB 102 37 37AG 37AH 37AS 120 120 120 2 Controller overview Electronic thermostats HDB controller NTC Controller 157 156 158 160 Product sections Index Air conditioning ...............................30 Heating ................................................72 Air treatment - chilled water ... 100 Air treatment - refrigerant .......130 Industrial ..........................................142 Controls ............................................154 3 Your direct Europe, Middle East and Africa Carrier EMEA – Headquarters 4 Rue Joseph Monier 92500 Rueil-Malmaison France Africa Carrier Africa FZE 28 km, Cairo Alexandria Desert Road 6th of October Giza, Egypt Australia AHI Carrier (Australia) Pty Ltd 101 Silverwater Road Silverwater Bag 62 Silverwater NSW 1811 Austria AHI Carrier GmbH Andromeda Tower Donau-City-Straße 6/9 1220 Vienna Azerbaijan Egypt Miraco Carrier 28 km, Cairo Alexandria Desert Road 6th of October Giza Finland Carrier Oy Vetokuja 4 01610 Vantaa France Carrier SCS (factory and French sales) Route de Thil BP 49 01122 Montluel Cédex Germany Carrier GmbH Edisonstrasse 2 D-85716 Unterschleissheim Greece AHI Carrier S.E. Europe Air-Conditioning S.A. 18, Kifissou Ave 104 42 Athens AHI Carrier MMC 44 Jafar Jabbarli Street Caspian Plaza, Baku AZ 1065 Azerbaijan Italy Lebanon Carrier SpA (factory) Via Raffaello Sanzio 9 20058 Villasanta MI Belgium Carrier SpA (factory and Italian sales) Via Sempione, 247 20016 Pero (MI) NTC Carrier PO Box 175704 Mar Mikhael Al Nahr Street, Tyan Building Beirut Carrier Airconditioning Benelux SA Bld. Sylvain Dupuis 243 1070 Bruxelles Bulgaria AHI Carrier Bulgaria Sofia Branch No. 25 Petar Dertliev Blvd. Floor 2 Liulin Region 1335 Sofia Czech Republic AHI Carrier CZ s.r.o. Komerční zóna Nupaky 310 25101 Nupaky (Praha - východ) Jordan NTC Carrier PO Box 9268/2369, Jebel El-Weibdeh Zuhair Khoury Building Amman 11191 Kazakhstan AHI Carrier LLP Office 30, Str Tole bi 89 Almaty 050000 Kuwait Kuwait American Air Conditioning K.S.C. P.O. Box 21326 13063 Safat 4 Netherlands Carrier Airconditioning Benelux BV PO Box 151 Rijndijk 141 2394 ZH Hazerswoude Rijndijk New Zealand AHI Carrier (NZ) Ltd 60 Stanley Street Parnell Auckland 1010 Poland Carrier Polska Sp. z.o.o. Ul. Konstruktorska 13 02-673 Warszawa line to Carrier Saudi Arabia United Arab Emirates Arabian Airconditioning Company Carrier Saudi Arabia PO Box 9784 Off Khurais Road Riyadh 11423 UTS Carrier LLC P.O. Box 6735 Next to Al Reef Bakery Zabeel Road Karama Dubai Slovakia AHI Carrier Slovakia, spol. s.r.o. Dobsinskeho 1 949 01 Nitra Republic of South Africa AHI Carrier South Africa (Pty) Ltd P.O. Box 39152 Booysens 2091 Spain Carrier España S.L. Avenida Real de Pinto, 91 Edificio C - Esc. 2 28021 Madrid Carrier Portugal Avenida do Forte 3 Edificio Suécia I, Piso 3 Carnaxide 2795 Linda a Velha Qatar Carrier Qatar WLL P.O. Box 23500 Jaidah Tower 8th Floor Doha Romania AHI Carrier Romania Bucharest Branch 270D Turnu Magurele Street Building A, Second Floor Apt. 1, Sector 4 RO-041713 Bucharest Middle East Operations Headquarters Carrier Middle East Limited (CMEL) Office # 2702, JAFZA View 19 Downtown Jebel Ali PO Box 61249 Dubai Asia and Pacific Operations Carrier International Corporation 76 Shenton Way # 17-00 Ong Building Singapore 079119 Sweden Portugal AHI Carrier Fzc B1-B22 Saif Zone P.O. Box 122341 Sharjah Carrier AB PO Box 8946 Aröds Industriväg 32 402 73 Göteborg Latin American Operations Alarko Carrier San. Ve Tic. A.S. Gebze Organize Sanayi Bolgesi Sahabettin Bilgisu Cad. 41480 Gebze-Kocaeli Carrier Corporation 2100 N.W. 88th Court Miami Florida 33172-2433 USA Ukraine North American Operations AHI Carrier LLC Moskovskiy Prospekt 9 Bldg. 3, 3-403 04073 Kiev Carrier Corporation Carrier Parkway Syracuse New York 13221 USA Turkey United Kingdom Toshiba Carrier UK Ltd United Technologies House Guildford Road Leatherhead, Surrey KT22 9UT Russian Federation AHI Carrier LLC Entrance 7, Floor 2 7 Kievskaya Street Moscow 121059 5 Carrier World Headquarters Carrier Corporation One Carrier Place Farmington Connecticut 06034-4015 USA 6 Carrier - experience backed by a large group Carrier is part of the United Technologies Corporation (UTC) which employs 199,900 people (2011), operates in approximately 180 countries, and is the 48nd largest corporation in the United States (Fortune list, 2012). The UTC group is a global technology corporation with a long history of pioneering innovation in aerospace, aviation, helicopter design, climate control, elevator design and hydrogen fuel cells. UTC Building & Industrial Systems is the world’s largest hightechnology building systems provider. The organization’s products include Otis elevators and escalators; Carrier heating, air-conditioning and refrigeration systems; and fire and security solutions from brands such as Kidde and Chubb. Supported by the leadership of UTC, Carrier is a source of ideas, technologies and innovation to help build a better world. Our mission is to make the world a better place to live. A mission that was born more than one hundred years ago when Willis Carrier invented the basics of modern air conditioning and developed the first air conditioning system. Since then we have created a comfortable, productive and healthy environment, regardless of climate, and we have ensured that the global food supply is transported and preserved for safe consumption. UTC Aerospace Systems is one of the world’s largest suppliers of technologically advanced aerospace and defense products. They design, manufacture and service systems and components and provide integrated solutions for commercial, regional, business and military aircraft, helicopters and other platforms. They are also a major supplier to international space programs. Our dedication to enhance our environment also means preserving the environment for everybody. Carrier was the first air conditioning manufacturer to use chlorine-free refrigerants that do not deplete the ozone layer. The specialists in commercial and military aircraft engines and space propulsion systems. For our commitment in developing products for a safer, cleaner and less polluted planet we received the prestigious Ozone Protection Award from the U.S. Environmental Protection Agency (EPA). Every day around the world a Carrier system is installed every eight seconds, and we are now the world’s largest manufacturer of air conditioning, ventilation, heating and commercial refrigeration systems. Carrier quality and reliability are incorporated and guaranteed in all products and systems. They are submitted to extensive tests before they are shipped to the customers and also certified by the major international organisations to guarantee authenticity of the information supplied, safety of the products and high process applications standards. All this means that the customer will receive a safe and reliable product. The world leader in the design and manufacture of helicopters for commercial, industrial and military use. 7 Natural leadership - sustain Pioneer in sustainability while introducing many of the world’s most energy-efficient heating, air conditioning, and refrigeration systems. At the same time, we’ve reduced the environmental impact of our operations. From the very beginning, Carrier Corporation has been a natural leader. Not simply for the fact that we created an entirely new and innovative product, but because as we did so, we set the standard in environmental responsibility. At a time when sustainability wasn’t on most minds, Carrier led the way. It was only natural. Our environmental commitment extends well beyond our walls to our communities and the marketplace. Carrier is the only company in the world to be a founding member of the U.S., Argentina, China, India, Singapore and France Green Building Councils. In fact, Carrier was instrumental in launching the U.S. Green Building Council in 1993 and was the first company in the world to join the organization. Carrier’s Rick Fedrizzi was the Council’s first chairman, and later went on to lead the organization as president and CEO. Over time, Carrier helped pioneer a new industry, and then pioneered environmentally sensitive products while reducing its own impact on the environment. We recognise the responsible balance between the technology we provide today and the world we live in tomorrow. Preservation of the environment and protecting our finite natural resources is a central tenet of our business. We have consistently demonstrated our adherence to these values by creating environmentally sound products that consume less energy and incorporate innovative materials. In 2008, Carrier was named as a formal international advisor to the China Green Building Council, having helped introduce the Green Building Council model to that country. Today, Carrier continues to improve the environmental performance of our products, services, operations and culture to help achieve a sustainable society and protect the natural environment for generations to come. Carrier is committed to reducing the greenhouse gas impact of our products through energy efficiency advancements and the refrigerants we use. Since 1994, we have led the industry in the phase-out of ozone-depleting refrigerants Carrier was among the first companies to set energy reduction goals for our factories in 1988. This led to our first company-wide global environmental, health and safety goals in 1997. From 2000 to 2011Carrier factories reduced water usage by From 2000 to 2011 Carrier factories reduced air emissions by 27% 60% 8 ability at Carrier Corporation “ Carrier has been an environmental leader for decades, with a clear and consistent strategy. ” Core values Geraud Darnis Carrier President Environmental Stewardship Performance Innovation from 2006 to 2011 Carrier has lowered greenhouse gas emissions by 35% Employee Development Customer Care Integrity Quality We were proud to receive the National Safety Council’s 2011 Robert W. Campbell Award, recognizing organizations that achieve business excellence by integrating environment, health and safety management into their business operating systems. 9 Green products and services Energy efficiency Carrier products turn energy into useful work. Because of their reliability and longevity, the energy efficiency of our products becomes part of our customers’ environmental footprint. This motivates us to design for the environment, creating products that consume fewer resources and produce fewer emissions during manufacture and operation. Air conditioning, heating and refrigeration systems require energy to operate, usually electricity or natural gas. We continually invest in research and development to expand the cost-effective energy-efficient range of our products. We do this because buildings consume about 40 percent of all energy worldwide. And according to the U.S. Department of Energy, heating and cooling account for 35 percent of the energy consumed in buildings in the U.S. In nearly every product category, we offer industry-leading, energy-efficient options for our customers. As the world leader in high-technology heating, air conditioning and refrigeration solutions, we are devoted to the advancement and application of the latest technologies. More than 2,000 scientists, engineers and technicians at research and design centres worldwide work to apply the newest technological innovations to the practical needs of millions of customers. Efficiency Carrier’s energy services operations have implemented more than $2.5 billion in energy savings at more than 2,000 customer sites. Carrier’s energy service operations have implemented more than $2.5 billion in energy savings at more than 2,000 sites, while our green building consulting services have helped the world’s largest companies and organizations, including the Beijing Olympic Village, achieve Leadership in Energy and Environmental Design (LEED) certification. Sustainability inside and out: our operations As the world’s leader in high-technology heating, air conditioning and refrigeration solutions, we believe market leadership demands environmental leadership. In fact, environmental stewardship is one of our company’s core values. Focused on reducing the impact of manufacturing operations across the globe, Carrier has set the industry standard for environmentally sound business practices and a commitment to sustainability across our products, services, operations and culture. Carrier was among early leaders to launch factory energy reduction goals in 1988, and expanded to broader global environmental, health and safety metrics in 1997. In 2003, Carrier, as a business unit of United Technologies Corporation, was the first manufacturer of heating, air conditioning and refrigeration systems to join the U.S. EPA Climate Leaders programme by declaring and reporting progress towards climate change goals. From 2000 to 2011, Carrier reduced its air emissions by 60 percent and water usage by 27 percent on an absolute basis. Since 2006, the company has lowered its greenhouse gas emissions by 35 percent. On the operations side, Carrier doubled sales but held factory energy use flat from 1997 through 2005. Since 2006, the company has exceeded its commitment to reduce greenhouse gas emissions by three percent each year. In 2009, two Carrier factories joined only nine others in the world to earn the U.S. Green Building Council’s LEED (Leadership in Energy and Environmental Design) rating for existing buildings — a first for the heating, air conditioning and refrigeration industry worldwide. In 2008, the Montluel factory became the first industrial site in France to use 100% of its electricity from renewable sources. Carrier implemented a new machine tool lubrication process that reduced volatile organic compound emissions by more than 80% below the baseline 10 Refrigerants For this achievement, the U.S. EPA awarded Carrier its “Best of the Best” Stratospheric Ozone Protection Award in 2007. Customers look to Carrier to develop sustainable solutions for refrigerants, especially given climate change considerations. Refrigerants are the gases that are compressed to create cooling for air conditioning and refrigeration. Many of these gases are chemicals with environmental impact. For decades, the industry relied on chlorofluorocarbon (CFC) chemicals as refrigerants due to their energy efficiency, safety and economic benefits. In the 1970s and 1980s, scientists began to observe that CFCs contributed to the depletion of the Earth’s stratospheric ozone layer that blocks harmful ultraviolet radiation from the sun. This led to an international accord to phase out ozone-depleting substances. Carrier did not wait for international mandates to move. We introduced the first commercial and residential air conditioning systems using non-ozone-depleting refrigerants in 1994 and have since led the industry away from ozone-depleting substances. Today, Carrier continues to help international markets meet new non-ozone-depleting requirements, while focusing on the next chapter of refrigerant evolution to reduce the direct greenhouse gas effect. Many of today’s refrigerants are based on hydrochlorofluorocarbon (HFC) chemicals because they do not deplete the ozone layer, and compared to CFCs, have reduced the greenhouse impact by as much as 80 percent. Nonetheless, HFCs remain a greenhouse gas and Carrier is committed to finding lower global-warming alternatives. We are a leader in providing commercial refrigeration systems for supermarkets using ultra-low global-warming carbon dioxide as a natural refrigerant. Carrier continuously invests in research and development. As we have done before, Carrier is committed to deploying products and technologies that minimize environmental impact while serving customer needs. This is equally true with refrigerants, where Carrier will have the right refrigerant solution for every application, while not every application may have the same refrigerant solution. Carrier pioneered the phase-out of CFCs for the air conditioning and refrigeration industry in 1994, two years ahead of U.S. requirements and 16 years before mandates in developing countries. The Carrier CO2NSERVATION Meter The Carrier CO2NSERVATION Meter calculates avoided greenhouse gas (GHG) emissions as a result of the installation of high-efficiency Carrier air conditioning, heating and refrigeration systems by customers around the world since 2000, and from NORESCO, an energy services business of UTC Climate, Controls & Security, since 2008. In 2011, the Carrier CO2NSERVATION Meter reached 100 million metric tonnes of greenhouse gases saved, equivalent to removing more than 19 million cars off the road for one year. UTC Climate, Controls & Security has consistently invested in energy-efficient technologies and solutions to assist its customers in lowering that energy demand and GHG emissions. The Carrier CO2NSERVATION Meter illustrates the avoided GHG emissions associated with energy-efficient products in use and emphasizes the impact of choosing more efficient products and services. Evergreen® 23XRV World’s leading screw efficiency chiller 40% better than the industry standard 11 Building Systems Whether you need air conditioning for a new building or a refurbishment project, for a commercial centre, an office application or an industrial process, Carrier can offer you a wide range of solutions to meet your needs - from liquid chillers/heat pumps, fan coils, air treatment/handling solutions right through to standard and tailor-made system controls. Each Carrier system is a global solution to guarantee optimised comfort and performance and rationalised investment - providing heating, ventilating and air conditioning solutions for individual customer comfort. Innovation Liquid chillers/heat pumps Some of the innovative products and technologies are: 1998 - The first Aquasnap air-cooled chillers (40-250 kW) with a compact design and an integrated hydronic module for reduced installation time and component sourcing. 2004 - The Aquasnap Puron (262-802 kW) was the first air-cooled chiller in its segment to use the new ozone-friendly refrigerant R-410A, with market-leading full and part load efficiencies in a clean, compact design. 2006 - The Aquaforce (252-1700 kW) air-cooled chiller brought another innovation - the all-aluminium MCHE condenser. This eliminates galvanic corrosion, reduces the refrigerant amount required by 30% and improves unit efficiency. The Aquasnap and Aquaforce ranges offer the patented DX free-cooling system that provides cooling without using the compressors to offer energy efficiency ratios (EER) of up to 28 to 1. … and for heating a range of desuperheater and heat recovery options to reclaim system heat for use in heating and for domestic hot water. 2009 - The new generation of Aquasnap chillers and heat pumps boasts increased energy efficiency and impressive new control options. 2010 - With the 61AF and 80AW/38AW Carrier launches a new series of heating products to complement the existing product range. 2012 - Introduction of the exclusive Greenspeed technology, leveraging inverterdriven screw compressors, used for the 30XW-V line to ensure high enery efficiency both at full and part load. Fan coil solutions The choice of the correct fan coil system depends on many factors. Carrier offers a range of fan coils to match any application requirements and installation criteria: in the room, in the ceiling, above a false ceiling, in a central plant room, and many more. The Carrier hydronic fan coil solutions guide compares the choices and helps customers to select the right solution for easy integration in the building and the associated air conditioning system. 12 and Solutions This includes hydronic systems - a reliable, flexible and ecological solution to meet the demands of today’s HVAC markets. All solutions allow cooling, heating, fresh air intake and a range of standard or customised controls. The Carrier product offer sets industry standards for exceptional performance, energy efficiency and reliability, and is based on more than a century of unmatched expertise, industry leadership and innovation. Air handling/air treatment solutions An important aspect of any HVAC system is the correct supply of fresh air and the cleaning, cooling and heating of the recycled air that building occupants breathe. Beyond the legal requirements there are health benefits and improved productivity that result. Carrier offers a vast range of standard and customised air handling solutions to ensure the best match to the requirements. Features include heat recovery, free cooling, variable speed and low energy consumption motors to ensure the best return on investment and minimal environmental impact. Control solutions Carrier equipment and system controls are available for standard system applications and customised, tailor made projects. The right choice is important to ensure complete customer satisfaction. Factors to consider include: t &OIBODFEFOFSHZFóDJFODZTZTUFNT t &BTZEJBHOPTUJDTBOENBJOUFOBODF t $BQBCJMJUZUPXPSLBVUPOPNPVTMZJGUIFTZTUFNGBJMT t 'MFYJCJMJUZBOEVQHSBEFQPTTJCJMJUZGPSMJGFMPOHTFSWJDFJOUIFCVJMEJOH Service and maintenance Carrier offers the most comprehensive commercial HVAC/R service schedules in the industry. Our technicians can service your chillers, rooftop units, compressors and boilers. We also provide preventive maintenance solutions to keep your system operating efficiently. We can design, replace or upgrade your equipment to optimise its performance, whether you have just one building or multiple sites nationwide. We can assess the energy needs of your facility and install and service energysaving solutions including micro-turbines, variable-speed drives and building automation and control systems. 13 Aquasmart ECO EFFICIENCY Carrier has been a market leader for more than 100 The Aquasmart system’s superior energy efficiency is the result of efficient equipment components, optimised by the Touch Pilot System Manager to complement the life of the building occupants. years, providing customers with heating, ventilation and air conditioning systems. Throughout the world we offer a wide choice of products and systems designed for years of reliable and trouble-free operation. With the increased focus on reducing energy consumption in buildings and related C02 emissions, Carrier continues to improve equipment efficiency and employs an integrated system approach for the COOLING AND HEATING highest overall savings. Rather than buying separate system elements we recommend to consider the system as a whole. The greatest savings are achieved when all heating, ventilation and air conditioning components are intelligently working together, speak the same language and communicate to allow intelligent FREE COOLING HEAT RECOVERY MEASURES At the right outdoor conditions free cooling can substantially lower energy consumption by reducing the need for mechanical cooling. Heat recovered from the building can be reclaimed for applications requiring hot water, such as comfort heating or sanitary purposes. system management and optimisation according to building use and outside environmental influences. The Aquasmart system, featuring the new Touch Pilot System Manager, can control and optimise In addition to being integrated within traditional free cooling systems, Carrier chiller ranges offer innovative integrated DX free-cooling systems to simplify the system and save space. Additional elements such as glycol, pumps and valves, used in traditional systems, are no longer necessary. commercial HVAC applications in up to 128 zones, reducing energy consumption and providing the desired individual comfort conditions. Aquasmart is a true ECO SYSTEM, offering considerable energy savings when compared with an equivalent traditional non-communicating Carrier offers a range of heat recovery options, including desuperheaters and heat recovery condensers. These can contribute to reduced heating energy usage or in some cases replace components that use alternative fuels. system. 89 87 SYSTEM CONTROL FOR INCREASED ENERGY SAVINGS * Source: Simulations made using Carriers Hourly Analysis Program (HAP). Savings quoted are influenced by factors including building type, use and geographical location. 2 kWh/m2/year* 14 Aquasmart AQUASMART A COMMUNICATING SYSTEM WITH OPTIMISED CONTROL AND INTEGRATED EFFICIENT COMPONENTS AIR TREATMENT PLANT VARIABLE WATER FLOW DEDICATED HEATING HEAT PUMPS VENTILATION AND HEAT RECOVERY Most applications only experience full-load design conditions for a few days each month and do not continuously require full design water flow. As an alternative to constant-flow applications Carrier offers integrated variable-speed pumps with reduced water flow at part load conditions. The reduced pump motor energy consumption at part-load conditions – most of the time during the year- results significant energy savings. Carrier has introduced a new generation of heat pumps, designed for heating applications. They deliver superior energy efficiency, hot water at temperatures of up to 63°C and allow operation at outdoor temperatures down to -20°C. Air treatment plants play an essential role in the indoor air quality of buildings, as they provide occupants with fresh air and remove volatile organic compounds from the occupied space. An air handling plant with heat recovery technology allows waste heat in the extracted air to be reclaimed, considerably reducing heat loads. 89 Replacing traditional heating equipment with heat pumps in hydronic systems can lead to substantial energy savings. 89 Night-time free cooling can further decrease system demands and energy consumption. 89 WATER TEMINALS (EC MOTORS/VARIABLE FAN SPEED) The use of terminals with electronically commutated (EC) motors results in improved motor efficiencies (<90%) and enhanced variable fan speed control. By better matching space loads at part load conditions, unit power consumption is reduced and improved air distribution and sound attenuation enhance occupant comfort. 89 86 81 58 53 8 kWh/m2/year* COMFORT DISTRIBUTION 36 kWh/m2/year* 31 kWh/m2/year* 15 3 kWh/m2/year* Aquasmart ECO MANAGEMENT OCCUPANCY-BASED CONTROL TO ELIMINATE WASTE ADAPT SYSTEM OPERATION TO MATCH SPACE AND TIME ZONE MANAGEMENT SCHEDULING Grouping similar areas in a building into zones will ensure a coherent and consistent system performance in these zones. Buildings may be zoned according to use, orientation or activity. Examples include offices, meeting rooms, print facilities and IT rooms. Control and adjustment of zone comfort conditions will help building owners and tenants to cut back energy consumption and save energy. Control and optimisation of the HVAC system operation to complement building activity will save energy - delivering the right conditions at the right time. Occupancy-based control with programmed comfort set points and intelligent start/stop system operation to match occupied and unoccupied periods can significantly reduce energy usage. The Aquasmart Touch Pilot can be used for normal and holiday scheduling. 89 86 3 kWh/m2/year* 16 Aquasmart ECO INTELLIGENCE ECO SYSTEMS GUARANTEE INTERACTIVE INTELLIGENCE THE ECO SYSTEM A COMMON LANGUAGE CENTRALISED MANAGEMENT OPTIMISED ECONOMIES All system components - the chillers or heat pumps, the ventilation system control and the water terminals need to speak the same language. The Touch Pilot System Manager ensures effective communication of actual and desired space conditions for efficient economical HVAC system control. The central Aquasmart Touch Pilot manages all system components so that building owners and users can ensure maximised energy reduction at ideal comfort conditions for building occupants. The Aquasmart Touch Pilot matches the system operation to meet the building requirements, where needed, when it is needed and as much as it is needed. This lowers energy consumption and optimises system performance. The combination of zone control, operating schedules and optimised unit-by-unit operating parameters can achieve maximised savings. 89 45 44 kWh/m2/year* 17 Carrier Service A full range of building and HVAC service options When any building’s equipment or controls service is relegated to an emergency response, business is at risk. Service is a year-round necessity in order to optimise efficiency, save money, help you make sound management decisions and free you from the anxiety of unplanned downtime. When you partner with Carrier, you ensure that critical comfort needs and regular service requirements are met, and you avoid adverse consequences of neglect. Carrier Corporation makes it easy for you to select a level of ongoing service that’s right for your operation. We are one of the best-trained service providers in the industry, with required ongoing factory, safety and ethics trainings for our personnel. Carrier technicians are highly skilled in all building systems assessment. They have access to advanced diagnostic tools analysis software, which will quickly and accurately evaluate your entire infrastructure and identify opportunities for improvements and cost savings. And our technicians can service equipment from any manufacturer. Benefits at a glance t $PNQSFIFOTJWF)7"$TZTUFNFWBMVBUJPOoPWFSBMM performance as well as individual chilled water and airside components t 3FNPUFNPOJUPSJOHGPSPOHPJOHQFSGPSNBODFUSBDLJOH and system adjustment t &OIBODFEDPNGPSUUPQSFTFSWFGBDJMJUZQSPEVDUJWJUZBOE tenant retention t $PTUFòFDUJWFTZTUFNJNQSPWFNFOUUPJODSFBTFQSPmUBCJMJUZ and enhance asset value t 1SPBDUJWFTZTUFNVQHSBEFTUPNJOJNJ[FSJTLTBTTPDJBUFE with emergency repairs and system failures t &YQFSUBTTFTTNFOUBOEHVJEBODFGPSSFQMBDFNFOUPG selected components to avoid large capital expenditures t &OFSHZDPOTFSWBUJPOTUSBUFHJFTUPSFEVDFDPTUT 18 Maintenance solutions Carrier offers a broad range of maintenance solutions for all brands of rooftops, chillers, split and VRF air conditioning, air handling units, controls and accessories. Carrier’s service agreements are tailored to meet the budget and operating needs of your facility and can include both preventive maintenance to keep your equipment running in peak condition and predictive maintenance services to identify potential problems before costly breakdowns occur. The optional Carrier remote monitoring is like having an expert service technician on-site, watching your equipment 24 hours a day, 7 days a week. Optimisation and modernisation Carrier Service can you show you how efficiency equals savings: Your chiller or heat pump may be running, but is it running as it is supposed to do? The Carrier Performance Analyzer tool has been developed to answer exactly this question. Our experts make real-time measurements on your equipment and make proposals on what can be improved so that you can get the most out of your equipment and protect your bottom line. Carrier can help you to: t $PNQMZXJUIOFXMFHJTMBUJPO t *NQSPWFUIFPQFSBUJPOBOESFMJBCJMJUZPGZPVSFRVJQNFOU t 3FEVDFSVOOJOHDPTUTUISPVHI$BSSJFSTFOFSHZTBWJOH high-efficiency products and controls t &YQMPSFCVJMEJOHBVUPNBUJPOBOEFOFSHZNBOBHFNFOU solutions with our experts Emergency service and repairs Parts Why not have your equipment repaired by those who know it best? Carrier Service takes pride in our fast response time when helping you with your emergency needs. We offer new and remanufactured compressors, a wide range of popular consumables, essential tools and genuine manufacturer’s replacement parts - all with the support of the industry expert. t 'BTUSFTQPOTF t &YQFSUUFDIOJDBMTVQQPSUXJUIGBDUPSZCBDLVQ t "UUSBDUJWFQSJDFT t &YQSFTTEFMJWFSZQPTTJCMF t -BSHFTUPDLTBOEDIPJDFPGCSBOET Our factory-trained service technicians use the latest diagnostic equipment and are able to perform adjustments or repairs on Carrier equipment as well as all other brands of Heating, Ventilation, Air Conditioning, and Controls equipment and systems. With Carrier as your partner, you can be confident that all repairs are done correctly. 19 Variable-speed water-cooled chillers and heat pumps 30XW-V 30XWHV t 4FBTPOBMFóDJFODZ t 3FMJBCJMJUZ t &DPOPNZ AIR CONDITIONING & HEATING SOLUTIONS Carrier has developed its own state-of-the-art answer to market-challenging requirements: a complete product range featuring new inverter-driven screw compressors, based on the successful Aquaforce series. The new line with Greenspeed technology offers increased global performance as well as Carrier’s acclaimed product quality, reliability and customer service support. t 7FSTBUJMJUZ 20 Choosing the right system for your application Green Building Capabilities · Design and certification · Audit and diagnostics · Energy analysis and tools · Innovative products for green buildings Carrier’s AdvanTE3C Solutions Center is a global group of Experts in Efficiency and Environment focused on developing sustainable building solutions. The AdvanTE3C Solutions Center is a natural evolution of Carrier’s approach to sustainability — and will support customers around the world in developing strategic, energy-efficient and custom-engineered building solutions. Carrier’s experts in the AdvanTE3C Solutions Center will apply today’s technology in an innovative fashion to capture even greater energy efficiency and environmental benefits. This will help drive innovation in commercial product designs, with a focus on new solutions. The breadth and depth of the Carrier product portfolio allow you to choose the right product for any application - heating, cooling or ventilation. The experience and know-how of the Carrier sales force will help you define the products that best meet your requirements. Willis Carrier invented modern air conditioning when he custom-engineered a unique solution to control temperature, humidity and indoor air quality for a Brooklyn printing plant. AdvanTE3C Solutions Center builds on that long legacy of customer-driven innovation and Carrier’s expertise in designing energy efficient and sustainable buildings for the future. 21 Console unit page 106 Ducted in-room unit page 108 22 Offices Ducted corridor unit page 112 Air-cooled chiller page 50 Cassette unit page 104 23 Console unit page 106 High-temperature heat pump page 82 Cassette unit page 104 Ducted in-room unit page 108 24 Concealed unit page 108 Hotels Air-cooled chiller page 44 Air handling unit page 124 Ducted in-room unit page 110 25 Air handling unit page 126 Air-to-water heat pump page 82 26 Industry Air condenser page 66 Water-cooled unit page 60 Aquasmart Touch Pilot page 162 Console unit page 106 Cassette unit page 104 27 Rooftop unit page 140 28 Commercial centre Air-cooled chiller page 40 Air condenser pages 66 Water-source heat pump 29 Air conditioning Index System architecture 30 Index Type Air-cooled units, axial fan With scroll or rotary compressors Range Refrigerant Cooling capacity, kW Page 30RB 008-015 30AWH 30RB 017-033 30RBY 017-033 30RBS 039-160 30RBSY 039-160 30RB 162-802 30RBM / 30RBP R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A 8-14 3-16 16-33 16-32 40-156 40-153 162-774 162-528 32 34 36 38 40 42 44 46 With screw compressors 30XAS 30XA 30XAV R-134a R-134a R-134a 232-486 267-1682 509-819 48 50 52 30WG/30WGA 30RW/30RWA 30HXC 30XW 30XW-V 23XRV R-410A R-407C R-134a R-134a R-134a R-134a 23-95 109-315 287-1302 273-1756 587-1741 970-1880 54 56 58 60 62 64 09AD 09TE 09AL 6 - 316 102-1092 106-1602 66 68 70 09FCAD 09FCTE 09FCAL 5 - 266 90-1008 89-1498 66 68 70 Water-cooled/condenserless units With scroll compressors With screw compressors Air-cooled condensers With axial fan Fluid coolers With axial fan Application of the new EN14511: 2013 chiller and heat pump performance standard: Chiller and heat pump performances are calculated in accordance with the EN14511: 2013 calculation standard and certified by Eurovent. The latest version of EN14511 uses a different method to take into account the contribution of water pumps, or heat exchanger pressure drops in the unit performances. The efficiency of the pump is no longer a default value, but a function of the required hydraulic power. In January 2012, the Eurovent Certification Company decided that this method is more realistic and it is fully applied starting from the 2012 certification campaign. The performances declared based on the new version of the standard were published on the ECC website www.eurovent-certification.com at the end of March 2012. IMPORTANT: Only 2012 performances rated according the new EN14511: 2013, taking in account water pump and heat exchanger pressure drop are certified by Eurovent. For units declared before 2012, the previous gross EER and COP values without pump correction (for units with integral pump - measured with the pump not running) and the corresponding energy classes are available on ECC website. Application rating conditions Air-cooled cooling Water-cooled cooling Air conditioning applications (AC) - condition 1 Evaporator EWT/LWT 12°C/7°C OAT 35°C Evaporator EWT/LWT 12°C/7°C Condenser EWT/LWT 30°C/35°C Cooling and heating floor applications (CHF) - condition 2 Evaporator EWT/LWT 23°C/18°C OAT 35°C Evaporator EWT/LWT 23°C/18°C Condenser EWT/LWT 30°C/35°C Legend EWT Entering water temperature LWT Leaving water temperature OAT Outdoor air temperature 31 AIR-COOLED LIQUID CHILLERS WITH INTEGRATED HYDRONIC MODULE Air conditioning 30RB Accessories Features t "RVBTOBQ+VOJPSSFNPUFDPOUSPMMFS t 5ISFFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t "RVBTOBQMJRVJEDIJMMFSTGFBUVSJOHUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOT incorporating scroll or rotary compressors, low-noise fans and operating on the ozone-friendly refrigerant R-410A. t 6OJUTIBWF&VSPWFOUFOFSHZFóDJFODZDMBTT"TJ[F PS#TJ[FTBOE t 6OJUTBSFBWBJMBCMFXJUIPSXJUIPVUJOUFHSBUFEIZESPOJDNPEVMFEFQFOEJOHPOUIF application. The integrated hydronic module reduces installation time and includes screen filter, water pump, expansion tank, safety valve and pressure gauge. t "VUPBEBQUJWFDPOUSPMBMHPSJUINQSFWFOUTFYDFTTJWFDPNQSFTTPSDZDMJOHBOE reduces the amount of water in the hydronic circuit (Carrier patent). t $PNQPOFOUTBSFTQFDJmDBMMZEFTJHOFEGPS3"SFGSJHFSBOU"MMVOJUTIBWF been submitted to the necessary laboratory tests to ensure perfect operation. t -BUFTUHFOFSBUJPOMPXOPJTFGBOTOPXFWFORVJFUFSBTUIFZEPOPUHFOFSBUF intrusive low-frequency noise. t 4DSPMMPSSPUBSZDPNQSFTTPSTSVORVJFUMZBOEWJCSBUJPOGSFFBOEBSFLOPXOGPS their durability and reliability. They are maintenance-free. t "JSNBOBHFNFOUTZTUFNDPOTJTUJOHPGUIFQSPQFMMFSGBOPSJmDFBOEBJSEJTDIBSHF grille, guarantees minimised sound levels. t 8JEFUFNQFSBUVSFPQFSBUJOHSBOHFVOJUTDBOPQFSBUFFóDJFOUMZJOFYUSFNF temperature conditions. They can work at low-ambient conditions (down to -10°C and up to 46°C outside temperature). t $PNQBDUVOJUEJNFOTJPOTSFEVDFEXFJHIUBOEFBTZBDDFTTUPBMMJOUFSOBM components facilitate installation. t "O).*HSBQIJDTFSWJDFJOUFSGBDFDBOCFVTFEUPNPOJUPSBOETFUVOJUPQFSBUJOH parameters. t 4QFDJBMMZTIBQFEBODIPSBHFGFFUFOTVSFDPSSFDUBOETBGFVOJUmYJOHUPUIF foundation. t *ODSFBTFEFOFSHZFóDJFODZBUQBSUMPBEUIFSFTVMUPGBMPOHRVBMJmDBUJPO and optimisation process. t 3FEVDFENBJOUFOBODFDPTUT Hydronic module 32 30RB 008-015 Physical data 30RB Air conditioning application as per EN14511-3:2013 Condition 1 Nominal cooling capacity EER Eurovent class, cooling ESEER Condition 2 Nominal cooling capacity EER Condition 3* Nominal cooling capacity EER Operating weight with/without hydronic module** Refrigerant charge (R410A)** Compressor Evaporator Condenser Hydronic circuit Net water volume Expansion tank capacity Maximum water-side operating pressure Fans Quantity Dimensions Length x depth x height NOTE: For the conditions, please refer to page 31. * ** 008 012 015 kW/kW 8.0 3.10 A 3.30 10.8 2.93 B 3.24 14.0 2.91 B 3.09 kW kW/kW 10.1 3.70 15.0 3.65 17.7 3.43 kW kW/kW kg 5.1 2.24 75.5/73.3 2.15 One hermetic rotary compressor Plate heat exchanger Copper tubes and aluminium fins 7.0 1.95 114/108 2.63 One hermetic scroll compressor 8.4 1.90 116/110 3.18 One hermetic scroll compressor l l kPa 1.0 2.3 2 2 300 300 Propeller fans with three blades, diameter 495 mm 1 2 2.3 2 300 908 x 350 x 821 908 x 350 x 1363 kW kW/kW mm 2 908 x 350 x 1363 Condition 3: Cooling mode conditions: evaporator water entering/leaving temperature 0°C/-5°C, outside air temperature 35°C, evaporator fouling factor 0 m2 K/W, with 20% ethylene glycol. Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30RB 008 012 015 Power circuit Nominal power supply ± 6% V-ph-Hz 400-3-50 + neutral 400-3-50 + neutral 400-3-50 + neutral 24 V via internal transformer Control circuit supply A 30 66 73 Maximum start-up current (Un)* kW 3.1 4.4 5.5 Maximum power input*’ A 4.5 6.3 9.1 Nominal operating current draw*** * Maximum instantaneous start-up current (locked rotor current of the compressor). ** Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. 150 1000 Leaving water temperature, °C 150 200 +5°C 1000 Clearances, mm 500 Operating range 300 1000 500 150 150 Outside air temperature, °C Operating range with anti-freeze solution and Pro-Dialog configuration. 33 AIR-COOLED CHILLERS Air conditioning 30AWH Options/accessories Features t 6OJUXJUIPVUIZESPOJDNPEVMF (option) t 6OJUXJUIIZESPOJDNPEVMFPQUJPO t 6OJUXJUIWBSJBCMFTQFFEQVNQ (option)* t "EEJUJPOBMPVUEPPSTFOTPSBDDFTTPSZ t 3FNPUFDPOUSPMMFS"83$ (accessory) t 1SPHSBNNBCMFUIFSNPTUBU 33AW-CS1 (accessory) t 5XPWFSTJPOTXJUIPSXJUIPVUIZESPOJDNPEVMFJOmWFTJ[FTXJUIOPNJOBMDPPMJOH capacities from 3 to 16 kW. t "RVB4OBQ1-64BJSDPPMFEDIJMMFSTXJUICVJMUJOJOWFSUFSUFDIOPMPHZXFSF designed for residential and light commercial applications. They offer excellent energy efficiency values, exceptionally quiet operation and meet the most stringent operating temperature demands. t 6OJUTJOUFHSBUFUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOTP[POFGSJFOEMZSFGSJHFSBOU R-410A, DC inverter twin-rotary compressors, low-noise fan and microprocessor control. t 4QFDJmDBMMZEFTJHOFEGPSFBTFPGJOTUBMMBUJPOBOETFSWJDFBOEVOEFSMJOJOH Carrier’s reputation for highest product quality and reliability. t "RVB4OBQ1-64DIJMMFSTDBOCFVTFEXJUIBXJEFDIPJDFPG$BSSJFSUFSNJOBM fan coil units - cassettes, low, medium and high-pressure satellite units, console units, underceiling units and high-wall units. t 8JEFPQFSBUJOHSBOHFPòFSJOHIJHIQFSGPSNBODFJOBXJEFUFNQFSBUVSF range. t %$JOWFSUFSUXJOSPUBSZDPNQSFTTPSTXJUI1VMTF"NQMJUVEF.PEVMBUJPO1". and Pulse Width Modulation (PWM) for enhanced reliability, low energy consumption and smooth vibration-free operation under all operating conditions. t 7BSJBCMFTQFFEGBOTXJUIBOJOOPWBUJWFQBUFOUFEGBOCMBEFTIBQFFOTVSF improved air distribution at exceptionally low noise levels. t "EWBODFEDJSDVJUEFTJHOBOEDPNQPOFOUTFMFDUJPOIBTSFTVMUFEJOBDPNQBDU unit with an exceptionally small footprint that can be easily transported even through narrow doors. t $PNQSFIFOTJWFRVBMJUZBOEFOEVSBODFUFTUT t &OIBODFEDPOUSPMQPTTJCJMJUJFT * Available in 2012 30AW controllers ComfortTM Series programmable thermostat 33AW-CS1 Remote controller 33AW-RC1 Technology 34 30AWH 004-015 Physical data 30AW Air conditioning application as per EN14511-3: 2013 Nominal cooling capacity EER ESEER Cooling floor application as per EN14511-3: 2013 Nominal cooling capacity EER Operating weight Unit with hydronic module Unit without hydronic module Refrigerant Compressor Fans Quantity/diameter Dimensions Length x depth x height 004 006 008 012 015 012-3Ph 015-3Ph kW kW/kW kW/kW 3.3 3.02 4.36 4.7 3.00 4.51 5.8 2.98 4.15 10.2 2.96 4.22 13.0 2.95 4.31 10.2 3 4.4 13.0 2.91 4.31 kW kW/kW 4.93 4.2 7.04 3.7 7.84 3.99 13.54 3.66 16.04 3.85 13.5 4.15 16 3.81 kg kg 57 54 R-410 61 58 R-410A 69 66 R-410A 116 113 R-410A 116 113 R-410A mm 1/495 1/495 1/495 2/495 2/495 mm 908 x 350 x 821 908 x 350 x 821 908 x 350 x 821 908 x 350 x 1363 908 x 350 x 1363 908 x 350 x 1363 908 x 350 x 1363 004 230-1-50 198-264 7.2 10 2.5 006 230-1-50 198-264 11 16 2.5 008 230-1-50 198-264 14 16 2.5 012 230-1-50 198-264 23 25 2.5 015 230-1-50 198-264 20 25 2.5 012-3Ph 400-3-50 376-424 16 20 2.5 015-3Ph 400-3-50 376-424 16 20 2.5 104 112 101 109 R-410A R-410A DC twin-rotary with PMV expansion valve Propeller fans 2/495 2/495 NOTE: For the conditions, please refer to page 31. Electrical data 30AW Power supply Voltage range Full load current Fuse rating Main power cable section V-ph-Hz V A A mm2 Operating range 20 18 30AWH 006 Leaving water temperature, °C 16 14 30AWH 004 12 10 8 6 4 2 0 -5 0 5 10 15 20 25 30 Outside air temperature, °C 35 35 40 45 50 AIR-COOLED LIQUID CHILLERS Air conditioning 30RB Options/accessories Features t 6OJUXJUIPVUIZESPOJDNPEVMF (option) t *OUFHSBUFEXBUFSmMMTZTUFNPQUJPO t 1PXFSTVQQMZXJUIPVUOFVUSBMPQUJPO t +#VT#BD/FUBOE-PO5BMLHBUFXBZT (accessory) t 3FNPUFJOUFSGBDFBDDFTTPSZ t *OUFHSBUFEXBUFSmMMTZTUFN (accessory) t 'PVSTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t "RVBTOBQMJRVJEDIJMMFSTGPSDPNNFSDJBMBQQMJDBUJPOTTVDIBTUIFBJSDPOEJUJPOJOH of offices and hotels. t &YDFQUJPOBMMZIJHIFOFSHZFóDJFODZBUQBSUMPBE&VSPWFOUFOFSHZFóDJFODZ class A and B (in accordance with EN14511-3: 2013). t -BUFTUUFDIOPMPHJDBMJOOPWBUJPOTJOUFHSBUFEP[POFGSJFOEMZSFGSJHFSBOU3" scroll compressors, low-noise fans and auto-adaptive microprocessor control. t 5IFVOJUTBSFFRVJQQFEXJUIBIZESPOJDNPEVMFJOUFHSBUFEJOUPUIFVOJUDIBTTJT limiting the installation to straight-forward operations like connection of the power supply and the water supply and return piping. t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 7FSUJDBMDPOEFOTFSDPJMTXJUIQSPUFDUJPOHSJMMFTPOBOUJWJCSBUJPONPVOUJOHT t -PXOPJTFGBOTOPXFWFORVJFUFS3JHJEGBOJOTUBMMBUJPOGPSSFEVDFETUBSUVQ noise. t 5IFVOJUIBTBTNBMMGPPUQSJOUBOEJTFODMPTFECZFBTJMZSFNPWBCMFQBOFMT t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 4ZTUFNBUJDPQFSBUJPOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPSTUFQ by-step verification of the instruments, electrical components and motors. t .BJOUFOBODFGSFFTDSPMMDPNQSFTTPSTBOEGBTUEJBHOPTJTPGQPTTJCMFJODJEFOUT and their history via the Pro-Dialog+ control reduce maintenance costs. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PSSPTJPOSFTJTUBODFUFTUTBDDFMFSBUFEBHFJOHUFTUPODPNQSFTTPSQJQJOHBOEGBO supports and transport simulation test on a vibrating table in the laboratory. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 36 Hydronic module (sizes 026-033 shown) 30RB 017-033 Physical data 30RB Air conditioning application as per EN14511-3: 2013 Condition 1 kW Nominal cooling capacity EER kW/kW Eurovent class ESEER kW/kW Condition 2 kW Nominal cooling capacity EER kW/kW Operating weight* Standard unit (with hydronic module) kg Standard unit (without hydronic module) kg Refrigerant* Compressor Control Fans Air flow l/s Evaporator Condenser Unit with hydronic module Power input* kW Nominal operating current** A Dimensions Length x depth x height mm NOTE: For the conditions, please refer to page 31. * 017 021 026 033 16.4 3.04 B 3.46 21.4 3.11 A 3.47 27.3 3.08 B 3.44 33.3 3.28 A 3.62 22.7 3.80 29.5 3.86 38.6 4.01 45.8 4.11 189 208 255 280 173 193 237 262 R-410A One hermetic scroll compressor Pro-Dialog+ Two twin-speed axial fans, 3 blades One twin-speed axial fan, 7 blades 2212 2212 3530 3530 Plate heat exchanger Copper tubes and aluminium fins One single-speed pump, screen filter, expansion tank, flow switch, pressure gauge, automatic air purge valve, safety valve 0.54 0.59 0.99 1.10 1.30 1.40 2.40 2.60 1136 x 584 x 1579 1136 x 584 x 1579 1002 x 824 x 1790 1002 x 824 x 1790 Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30RB 017 021 026 033 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit supply A 75 95 118 118 Maximum start-up current (Un)* kW 7.8 9.1 11 13.8 Maximum operating power input** A 8 12 16 17 Nominal unit operating current draw*** * Maximum instantaneous start-up current (locked rotor current of the compressor). ** Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. Operating range 53 48 Outside air temperature, °C 43 38 33 28 23 18 13 8 3 -2 -7 -12 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 Evaporator leaving water temperature, °C Operating range with anti-freeze solution and Pro-Dialog configuration. 37 DUCTABLE AIR-COOLED LIQUID CHILLERS Air conditioning 30RBY Options/accessories Features t )ZESPOJDNPEVMFPQUJPO t *OUFHSBUFEXBUFSmMMTZTUFNPQUJPO accessory) t *OMFUEVDUGSBNFPQUJPO t *OMFUmMUFSGSBNFPQUJPO t +#VT#BD/FUBOE-PO5BMLHBUFXBZT (accessory) t 3FNPUFJOUFSGBDFBDDFTTPSZ t $POEFOTBUFESBJOQBOBDDFTTPSZ t 'PVSTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t "RVBTOBQMJRVJEDIJMMFSTGPSDPNNFSDJBMBQQMJDBUJPOTTVDIBTUIFBJSDPOEJUJPOJOH of offices and hotels. t &YDFQUJPOBMMZIJHIFOFSHZFóDJFODZBUQBSUMPBE&VSPWFOUFOFSHZFóDJFODZ class A and B (in accordance with EN14511-3: 2013). t -BUFTUUFDIOPMPHJDBMJOOPWBUJPOTJOUFHSBUFEP[POFGSJFOEMZSFGSJHFSBOU3" scroll compressors, low-noise fans and auto-adaptive microprocessor control. t 5IFVOJUTBSFFRVJQQFEXJUIBIZESPOJDNPEVMFJOUFHSBUFEJOUPUIFVOJUDIBTTJT limiting the installation to straight-forward operations like connection of the power supply, the water supply and return piping and the air distribution ducting. t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 7FSUJDBMDPOEFOTFSDPJMTXJUIQSPUFDUJPOHSJMMFTPOBOUJWJCSBUJPONPVOUJOHT t -PXOPJTFGBOTOPXFWFORVJFUFS3JHJEGBOJOTUBMMBUJPOGPSSFEVDFETUBSUVQOPJTF t &BTZEVDUDPOOFDUJPOBOEGBOTXJUI1BBWBJMBCMFQSFTTVSF t 5IFVOJUIBTBTNBMMGPPUQSJOUBOEJTFODMPTFECZFBTJMZSFNPWBCMFQBOFMT t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 4ZTUFNBUJDPQFSBUJPOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPSTUFQ by-step verification of the instruments, electrical components and motors. t .BJOUFOBODFGSFFTDSPMMDPNQSFTTPSTBOEGBTUEJBHOPTJTPGQPTTJCMFJODJEFOUT and their history via the Pro-Dialog+ control reduce maintenance costs. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PSSPTJPOSFTJTUBODFUFTUTBDDFMFSBUFEBHFJOHUFTUPODPNQSFTTPSQJQJOHBOEGBO supports and transport simulation test on a vibrating table in the laboratory. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 38 Hydronic module, sizes 026-033 30RBY 017-033 Physical data 30RBY Air conditioning application as per EN14511-3: 2013 Condition 1 kW Nominal cooling capacity EER kW/kW Eurovent class ESEER kW/kW Condition 2 kW Nominal cooling capacity EER kW/kW Operating weight* Standard unit (with hydronic module) kg Standard unit (without hydronic module) kg Refrigerant* Compressor Control Fans Air flow l/s Evaporator Condenser Unit with hydronic module Power input* kW Nominal operating current** A Dimensions Length x depth x height mm NOTE: For the conditions, please refer to page 31. * 017 021 026 033 15.7 2.53 B 2.81 20.3 2.52 B 2.72 27.0 2.76 A 3 32.3 2.95 A 3.18 19.9 2.96 24.8 2.78 36.1 3.36 42.3 3.56 209 228 255 280 193 213 237 262 R-410A One scroll compressor Pro-Dialog+ Two twin-speed centrifugal fans, 5 backward-curved blades One twin-speed axial fan, 7 blades 1640 1640 3472 3472 One plate heat exchanger Copper tubes and aluminium fins One single-speed pump, screen filter, expansion tank, flow switch, water circuit drain valve, pressure gauge, automatic air purge valve, safety valve 0.54 0.59 0.99 1.10 1.30 1.40 2.40 2.60 1135 x 584 x 1608 1135 x 584 x 1608 1002 x 824 x 1829 1002 x 824 x 1829 Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30RBY 017 021 026 033 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit supply A 75 95 118 118 Maximum start-up current (Un)* kW 8.0 9.3 11.2 14.0 Maximum operating power input** A 13 16 20 24 Maximum operating current draw*** * Maximum instantaneous start-up current (locked rotor current of the compressor). ** Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Operating range 53 48 Outside air temperature, °C 43 38 33 28 23 18 13 8 3 -2 -7 -12 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 Evaporator leaving water temperature, °C Operating range with anti-freeze solution and Pro-Dialog configuration. 39 AIR-COOLED LIQUID CHILLERS Air conditioning 30RBS Options Features t $POEFOTFSXJUIBOUJDPSSPTJPOQPTU treatment t $POEFOTFSXJUIQSFUSFBUFEmOT t $PJMQSPUFDUJPOHSJMMFT t 7FSZMPXMFBWJOHXBUFSUFNQFSBUVSF t -PXMFBWJOHXBUFSUFNQFSBUVSF t 7FSZMPXOPJTFMFWFM t 4PGUTUBSUFS3#4 t 8JOUFSPQFSBUJPO t 'SPTUQSPUFDUJPOEPXOUP¡$ t )JHIBOEMPXQSFTTVSFTJOHMFBOE dual-pump hydronic modules with or without expansion tank t )JHIQSFTTVSFWBSJBCMFTQFFETJOHMF and dual-pump hydronic modules with or without expansion tank t 1BSUJBMIFBUSFDMBJN t &OWJSP4IJFMEPS4VQFS&OWJSP4IJFME anti-corrosion protection for MCHE heat exchangers t +#VT#BD/FUBOE-PO5BMLHBUFXBZT t &WBQPSBUPSTDSFXPSXFMEFE connection sleeves t .BTUFSTMBWFPQFSBUJPO t 3FNPUFJOUFSGBDF t &MFWFOTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t "RVBTOBQMJRVJEDIJMMFSTGPSDPNNFSDJBMPSJOEVTUSJBMBQQMJDBUJPOT t -BUFTUUFDIOPMPHJDBMJOOPWBUJPOTJOUFHSBUFEP[POFGSJFOEMZSFGSJHFSBOU3" scroll compressors, low-noise fans made of a composite material, auto-adaptive microprocessor control, electronic expansion valve and variable-speed pump (option). t &VSPWFOUFOFSHZFóDJFODZDMBTT$BOE% (in accordance with EN14511-3: 2013). t "MMBMVNJOJVNNJDSPDIBOOFMDPOEFOTFS.$)& GPSSFEVDFE refrigerant charge. t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 7FSUJDBMDPOEFOTFSDPJMTXJUIQSPUFDUJPOHSJMMFTPQUJPO t -PXOPJTF'MZJOH#JSE*7GBOTNBEFPGBDPNQPTJUFNBUFSJBM3JHJEGBO installation for reduced start-up noise. t 4NBMMVOJUGPPUQSJOUBOEBMPXIFJHIUNN FODMPTFECZFBTJMZSFNPWBCMF panels. t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 4ZTUFNBUJDPQFSBUJPOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPSTUFQ by-step verification of the instruments, electrical components and motors. t 4FWFSBMDPNQSFTTPSTDPOOFDUFEJOQBSBMMFM t 5IFFMFDUSPOJDFYQBOTJPOEFWJDF&97 BMMPXTPQFSBUJPOBUBMPXFSDPOEFOTJOH pressure (EER optimisation), and dynamic superheat management optimises the utilisation of the evaporator heat exchange surface. t .BJOUFOBODFGSFFTDSPMMDPNQSFTTPSTBOEGBTUEJBHOPTJTPGQPTTJCMFJODJEFOUT and their history via the Pro-Dialog+ control reduce maintenance costs. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PSSPTJPOSFTJTUBODFUFTUTBDDFMFSBUFEBHFJOHUFTUPODPNQSFTTPSQJQJOH and fan supports and transport simulation test on a vibrating table in the laboratory. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 40 30RBS 039-160 Physical data 30RBS Air conditioning application as per EN14511-3: 2013 Condition 1 kW Nominal cooling capacity EER kW/kW Eurovent class ESEER kW/kW Condition 2 kW Nominal cooling capacity EER kW/kW Operating weight (with MCHE heat exhangers)* Standard unit without hydronic module kg Standard unit with hydronic module Single high-pressure pump kg Dual high-pressure pump kg Compressors Circuits A/B Refrigerant* Capacity control Condensers Fans Quantity Total air flow (at high speed) l/s Evaporator Hydronic module (option) mm Dimensions, length x depth x height 039 045 050 060 070 080 090 100 120 140 160 40 2.87 C 3.75 44 2.76 C 3.88 51 2.67 D 3.95 58 2.66 D 3.80 67 2.72 C 3.62 79 2.70 C 3.67 87 2.73 C 3.91 97 2.73 C 3.94 114 2.67 D 3.83 135 2.70 C 3.68 156 2.65 D 3.87 53 3.44 59 3.32 69 3.12 81 3.31 85 2.97 98 3.06 114 3.18 126 3.09 151 3.10 171 2.99 194 3.01 443 451 454 463 467 482 780 791 807 912 943 951 988 982 1019 2/2 2/2 2 10600 2 10600 473 481 484 493 496 511 812 823 843 499 507 510 519 522 537 857 868 891 Hermetic scroll compressors, 48.3 r/s 2/2/2/2/2/2/3/3/3/R-410A Pro-Dialog+ All aluminium micro-channel heat exchanger (MCHE) Axial Flying Bird IV with rotating shroud 1 1 1 1 1 1 2 2 2 3800 3800 3800 3800 5300 5300 7600 7600 7600 Direct expansion plate heat exchanger Single or dual pump, Victaulic screen filter, safety valve, expansion tank, purge valves (water and air), pressure sensors 1061 x 2050 x 1330 2258 x 2050 x 1330 NOTE: For the conditions, please refer to page 31. * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30RBS without hydronic module 039 045 050 060 070 080 090 100 120 140 160 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit supply Maximum start-up current (Un)* Standard unit A 113.8 134.8 142.8 145.8 176.0 213.0 173.6 207.6 247.6 243.0 286.0 Unit with electronic starter option A 74.7 86.5 93.8 96.2 114.4 139.8 kW 19.5 22.3 24.5 27.9 31.2 35.8 42.3 45.6 52.5 62.4 71.6 Maximum operating power input** A 25.6 29.0 33.0 36.0 42.4 52.8 55.4 61.7 77.3 84.8 105.6 Nominal unit operating current draw*** * Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). ** Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: evaporator entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. Operating range 55 Full load Minimum load Outside air temperature, °C 45 35 25 15 5 -5 30RBS -15 -25 0 5 10 15 20 Evaporator leaving water temperature, °C 25 NOTE: This operating range applies up to 130 Pa static pressure without suction duct for sizes 070-080 and 140-160, and up to 240 Pa for all other sizes. 41 DUCTABLE AIR-COOLED LIQUID CHILLERS Air conditioning 30RBSY Options Features t $POEFOTFSXJUIBOUJDPSSPTJPOQPTU treatment t $POEFOTFSXJUIQSFUSFBUFEmOT t 4VDUJPOBJSmMUFSTNPVOUFEPOSBJMT t $PJMQSPUFDUJPOHSJMMFT t 7FSZMPXOPJTFMFWFM t 4PGUTUBSUFS3#4: t 'SPTUQSPUFDUJPOEPXOUP¡$ t )JHIBOEMPXQSFTTVSFTJOHMFBOE dual-pump hydronic modules with or without expansion tank t )JHIQSFTTVSFWBSJBCMFTQFFETJOHMF and dual-pump hydronic modules with or without expansion tank t 1BSUJBMIFBUSFDMBJN t &OWJSP4IJFMEPS4VQFS&OWJSP4IJFME anti-corrosion protection for MCHE heat exchangers t +#VT#BD/FUBOE-PO5BMLHBUFXBZT t &WBQPSBUPSTDSFXPSXFMEFE connection sleeves t .BTUFSTMBWFPQFSBUJPO t 3FNPUFJOUFSGBDF t &MFWFOTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t %VDUBCMF"RVBTOBQMJRVJEDIJMMFSTGPSDPNNFSDJBMPSJOEVTUSJBMBQQMJDBUJPOT5IF units include inverter fans to maximise EERs at all operating conditions. t -BUFTUUFDIOPMPHJDBMJOOPWBUJPOTJOUFHSBUFEP[POFGSJFOEMZSFGSJHFSBOU3" scroll compressors, low-noise fans made of a composite material, auto-adaptive microprocessor control, electronic expansion valve and variable-speed pump (option). t &YDFQUJPOBMMZIJHIFOFSHZFóDJFODZBUQBSUMPBE&VSPWFOUFOFSHZFóDJFODZ class A and B (in accordance with EN14511-3: 2013). t "MMBMVNJOJVNNJDSPDIBOOFMDPOEFOTFS.$)& GPSFYUSBFóDJFODZ t "WBJMBCMFTUBUJDQSFTTVSFPGVQUP1BGPSTJ[FTUPBOEUP and up to 180 Pa for sizes 070 to 080 and 140 to 160. t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 7FSUJDBMDPOEFOTFSDPJMTXJUIQSPUFDUJPOHSJMMFTPQUJPOPOTJ[FT t -PXOPJTF'MZJOH#JSE*7GBOTNBEFPGBDPNQPTJUFNBUFSJBM3JHJEGBO installation for reduced start-up noise. t 4NBMMVOJUGPPUQSJOUBOEBMPXIFJHIUNN FODMPTFECZFBTJMZSFNPWBCMF panels. t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 4ZTUFNBUJDPQFSBUJPOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPSTUFQ by-step verification of the instruments, electrical components and motors. t 4FWFSBMDPNQSFTTPSTDPOOFDUFEJOQBSBMMFM t 5IFFMFDUSPOJDFYQBOTJPOEFWJDF&97 BMMPXTPQFSBUJPOBUBMPXFSDPOEFOTJOH pressure (EER optimisation), and dynamic superheat management optimises the utilisation of the evaporator heat exchange surface. t .BJOUFOBODFGSFFTDSPMMDPNQSFTTPSTBOEGBTUEJBHOPTJTPGQPTTJCMFJODJEFOUT and their history via the Pro-Dialog+ control reduce maintenance costs. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PSSPTJPOSFTJTUBODFUFTUTBDDFMFSBUFEBHFJOHUFTUPODPNQSFTTPSQJQJOH and fan supports and transport simulation test on a vibrating table in the laboratory. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 42 30RBSY 039-160 Physical data 30RBSY 039 045 050 060 070 080 090 100 Air conditioning application as per EN14511-3 : 2013 Condition 1 kW 39.6 44.0 51.2 58.1 66.2 77.7 86.7 97.1 Nominal cooling capacity EER kW/kW 2.93 2.81 2.66 2.7 2.68 2.65 2.71 2.72 Eurovent class A A B A B B A A ESEER kW/kW 3.93 4.04 3.98 3.9 3.72 3.75 3.86 3.89 Condition 2 kW 53.0 58.9 68.5 80.9 83.6 97.0 114.4 126.5 Nominal cooling capacity EER kW/kW 3.50 3.38 3.14 3.36 2.91 2.99 3.16 3.08 Operating weight (with MCHE heat exhangers)* Standard unit without hydronic module kg 450 458 461 473 473 491 785 795 Standard unit with hydronic module Single high-pressure pump kg 480 488 491 503 503 521 817 827 Dual high-pressure pump kg 506 513 516 528 529 547 862 872 Hermetic scroll compressors, 48.3 r/s Compressors Circuits A/B 2/2/2/2/2/2/3/3/R-410A Refrigerant* Pro-Dialog+ Capacity control All aluminium micro-channel heat exchanger (MCHE) Condensers Axial Flying Bird IV with rotating shroud Fans Quantity 1 1 1 1 1 1 2 2 Total air flow (at high speed) l/s 3800 3800 3800 3800 4600 4600 7600 7600 Direct expansion plate heat exchanger Evaporator Single or dual pump, Victaulic screen filter, safety valve, expansion tank, purge valves (water and air), pressure sensors Hydronic module (option) Dimensions** Length mm 2109 2109 2109 2142/2307 2109 2142/2307 2273 2273 Depth x height mm 1132/1297 x 1371 2122 x 1371 NOTE: For the conditions, please refer to page 31. * ** 120 140 160 114.4 2.68 B 3.87 132.8 2.66 B 4.12 153.4 2.6 B 4.28 150.9 3.11 168.9 2.93 191.7 2.94 811 917 947 847 896 956 993 986 1023 3/- 2/2 2/2 2 7600 2 9200 2 9200 2273 2273 2273 Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. The first value is for units without filter frame, and the second value is for units with option 23B and filter frame. Electrical data 30RBSY without hydronic module 039 045 050 060 070 080 090 100 120 140 160 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit supply Maximum start-up current (Un)* Standard unit A 116.4 137.4 145.4 148.4 176.4 213.4 178.8 212.8 252.8 243.8 286.8 Unit with electronic starter option A 74.7 86.5 93.8 96.2 114.4 139.8 kW 21.2 24.0 26.2 29.6 31.8 36.4 45.7 49.0 55.9 63.6 72.8 Maximum operating power input** A 28.2 31.6 35.6 38.6 42.8 53.2 60.6 66.9 82.5 85.6 106.4 Nominal unit operating current draw*** * Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). ** Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: evaporator entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. Operating limits 55 Full load Minimum load Outside air temperature, °C 45 35 25 15 5 -5 -15 30RBSY -25 0 5 10 15 20 Evaporator leaving water temperature, °C 25 NOTE: This operating range applies up to 130 Pa static pressure without suction duct for sizes 070-080 and 140-160, and up to 240 Pa for all other sizes. 43 AIR-COOLED LIQUID CHILLERS WITH INTEGRATED HYDRONIC MODULE Air conditioning 30RB Options Features t -PXMFBWJOHXBUFSUFNQFSBUVSFGSPN +3°C to -10°C (162-402) t 6OJUTGPSJOEPPSJOTUBMMBUJPOXJUI discharge ducts t -PXBOEWFSZMPXOPJTFMFWFMT t (SJMMFTPOBMMGPVSVOJUGBDFT t &ODMPTVSFQBOFMTFBDIFOE t &MFDUSPOJDTUBSUFS t 8JOUFSPQFSBUJPOUP¡$PS¡$ t &WBQPSBUPSJODVEJOHXBUFSQJQJOH and evaporator and hydronic module frost protection (162-522) t 1BSUJBMIFBUSFDMBJN t 5PUBMIFBUSFDMBJN t .BTUFSTMBWFPQFSBUJPO t .BJOEJTDPOOFDUTXJUDIXJUIPS without fuse (302-802) t &WBQPSBUPSBMM PSFWBQPSBUPS hydronic module (302-522) with aluminium jacket t $PNQSFTTPSTVDUJPOWBMWF PS suction & discharge valves (162-262) t )JHIMPXQSFTTVSFTJOHMFEVBM pump hydronic modules (162-522) t +#VT#BD/FUPS-PO5BMLHBUFXBZT t %9GSFFDPPMJOHTZTUFN t &OFSHZ.BOBHFNFOU.PEVMF&.. t 'JUUFETBGFUZWBMWFT t $POGPSNTUP"VTUSBMJBODPEFT t 6OJUTUPSBHFBCPWF¡$ t .$)&BOUJDPSSPTJPOQSPUFDUJPO t 4IFMMBOEUVCFFWBQPSBUPS t $POOFDUJPOTMFFWF t 1PXFSDBCMFDPOOFDUJPOTJEF extension (302-802) t 'JWFTJ[FTUP XJUIQMBUFIFBUFYDIBOHFSBOETJYUFFOTJ[FTUP with shell-and-tube heat exchanger with cooling capacities from 162 to 774 kW. t &VSPWFOUFOFSHZFóDJFODZDMBTTJOBDDPSEBODFXJUI&/ #UP% t "RVBTOBQMJRVJEDIJMMFSTGFBUVSJOHUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOTBOE operating on the ozone-friendly refrigerant R-410A. t "MMBMVNJOJVNNJDSPDIBOOFMDPOEFOTFS.$)& GPSFYUSBFóDJFODZ t *OUFHSBUFEIZESPOJDNPEVMFPQUJPO XJUIXBUFSQVNQBOEFYQBOTJPOUBOL t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFMT t 7TIBQFEDPOEFOTFSDPJMTBMMPXJOHRVJFUFSBJSnPXBDSPTTUIFDPJM t -PXOPJTFUIHFOFSBUJPO'MZJOH#JSEGBOTOPXFWFORVJFUFS4JNQMJmFE electrical connections. t 'BTUDPNNJTTJPOJOHBTBMMVOJUTBSFTZTUFNBUJDBMMZSVOUFTUFECFGPSFTIJQNFOU t &DPOPNJDBMPQFSBUJPOXJUIJODSFBTFEFOFSHZFóDJFODZBUQBSUMPBEBOE dynamic superheat management. t -FBLUJHIUSFGSJHFSBOUDJSDVJUBOESFEVDFENBJOUFOBODFDPTUT t "VUPBEBQUJWFDPOUSPMBMHPSJUINBOEBVUPNBUJDDPNQSFTTPSVOMPBEJOHGPS increased reliability. t &YDFQUJPOBMFOEVSBODFUFTUT A A B B Pro-Dialog Plus operator interface 44 R 30RB 162-802 Physical data 30RB 162-262 “B” and 30RB 302-802 units 162 182 202 232 262 302 Air conditioning application as per EN14511-3: 2013 kW 170 184 208 222 265 297 Nominal cooling capacity EER kW/kW 2.95 2.96 2.86 3.00 2.67 2.77 Eurovent class B B C B D C ESEER kW/kW 3.71 3.53 3.82 3.87 3.69 3.80 Hermetic scroll, 48.3 r/s Compressors R-410A Refrigerant* Pro-Dialog Plus Capacity control All aluminium micro-channel heat exchanger (MCHE) Condensers Axial Flying Bird 4 with rotating shroud Fans Quantity 3 4 4 4 4 5 342 372 402 432 462 522 602 672 732 802 331 2.69 D 3.81 366 2.80 C 3.95 395 2.60 D 3.72 422 2.71 C 3.71 452 2.59 D 3.65 503 2.58 D 3.56 607 2.72 C 3.97 657 2.68 D 3.88 712 2.59 D 3.75 774 2.58 D 3.71 5 6 6 7 7 8 9 10 11 12 31597 31597 36111 40623 45139 49653 54167 Total air flow (high speed) l/s 13542 18056 18056 18056 18056 22569 22569 27083 27083 Twin-circuit plate heat exchanger Direct expansion, shell-and-tube Evaporator Dimensions** mm 2457 x 2253 x 2297 3604 x 3353 x 2297 Length x depth x height NOTE: For the conditions, please refer to page 31. For 30RB 162-262 units with option 280 (shell-and-tube heat exchanger) please refer to the specific product literature * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. 4798 x 2253 x 2297 5992 x 2253 x 2297 7186 x 2253 x 2297 Electrical data, 30RB 162-262 “B” and 30RB 302-802 units 30RB (without hydronic module) 162 182 202 232 262 302 342 372 402 432 462 522 602 672 732 802 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V, via internal transformer Control circuit supply kW 76/85/98/102/- 127/- 140/- 159/- 172/- 191/- 204/- 223/- 255/- 191/96 191/127 255/96 255/127 Max. power input* - circuits A + B/C A 101/- 113/- 129/- 135/- 167/- 185/- 209/- 227/- 251/- 269/- 293/- 334/- 251/125 251/167 334/125 334/167 Nom. current draw** - circuits A + B/C A 304/- 353/- 375/- 348/- 426/- 448/- 481/- 502/- 535/- 557/- 590/- 645/- 535/371 535/426 645/371 645/426 Max. start-up current*** - circuits A + B/C * Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). ** Nom. unit current draw at standardised Eurovent conditions: evaporator entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. *** Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Note: Units 30RB 602-802 have two electrical connection points. Operating range 30RB 162-262 “B” units and units with option 280 30RB 302-802 units -10 -10 -20 -20 5 Leaving evaporator water temperature, °C 15 3.3 Leaving evaporator water temperature, °C Legend: Notes: Evaporator ΔT = 5 K The evaporator is protected against frost down to -20°C. Standard unit operating at full load. Operating range, units equipped with options 28, 28B and 28C “Winter operation”. Option 28 (with variable-speed lead fan for each circuit) allows operation down to -20°C outside temperature. Option 28B, 28C (with two-speed lead fan for each circuit) allows operation down to -10°C outside temperature. In addition to options 28, 28B and 28C the unit must either be equipped with the evaporator frost protection option (for units without hydronic module option) or the evaporator and hydronic module frost protection option (for units with hydronic module option) or the water loop must be protected by the installer by adding a frost protection solution. 45 15 Option 28 Option 28B, 28C Option 28B, 28C Option 28 10 Entering air temperature, °C 48 Option 28B, 28C for size 162 Entering air temperature, °C 48 AIR-COOLED LIQUID CHILLERS WITH INTEGRATED HYDRONIC MODULE Air conditioning 30RBM/30RBP Options t -PXMFBWJOHXBUFSUFNQFSBUVSFEPXO to -6°C* t 7FSZMPXMFBWJOHXBUFSUFNQFSBUVSF down to -12°C* t )JHITUBUJDGBOGPSEVDUFEBQQMJDBUJPO t -PXOPJTFMFWFM t 7FSZMPXOPJTFMFWFM t (SJMMFT t 4JEFQBOFMT t &MFDUSPOJDTUBSUFS t 8JOUFSPQFSBUJPOGPS0"5EPXOUP -10°C t 8JOUFSPQFSBUJPOGPS0"5EPXOUP -20°C t )JHIBNCJFOU t &WBQPSBUPSGSPTUQSPUFDUJPO t &WBQPSBUPSBOEIZESPOJDNPEVMFGSPTU protection t 1BSUJBMIFBUSFDMBJN t 5PUBM)FBUSFDMBJN t .BTUFSTMBWFPQFSBUJPO t 4VDUJPOBOEEJTDIBSHFWBMWFT t )ZESPOJDNPEVMFXJUIIJHIQSFTTVSF single or dual pump t )ZESPOJDNPEVMFXJUIMPXQSFTTVSF single or dual pump t )ZESPOJDNPEVMFXJUIHSFFOTQFFE¥ single or dual pump t &YQBOTJPOUBOL t %JSFDUFYQBOTJPOGSFFDPPMJOHPOFPS two circuits)* t )ZESPOJDGSFFDPPMJOH t +#VT#BD/FUPS-PO5BMLHBUFXBZT t &OWJSP4IJFME4VQFS&OWJSP4IJFME coatings for MCHE coils t $POOFDUJPOTMFFWF t 7FMFDUSJDBMQMVH t 5PVDI1JMPUPQFSBUPSJOUFSGBDF t 1PXFS'BDUPSDPSSFDUJPO t &MFDUSJDFOFSHZNFUFS Features t Twelve sizes with nominal cooling capacities from 164 to 528 kW t Aquasnap liquid chillers for commercial and industrial applications. t 30RBM version with full load energy efficiency up to 3.1 (in accordance with EN14511-3: 2013) t 30RBP version with enhanced part-load energy efficiency using greenspeed® condenser fans. t 30RBP version with greenspeed® condenser fans for start-stop noise elimination. t Extra energy savings through multiple options*: greenspeed® variable speed pump, partial or total heat reclaim, partial or total free-cooling, electric energy meter. t All-aluminium micro-channel condenser (MCHE) and brazed plate heat exchanger for low R-410A refrigerant charge. t Night mode control. t V-shaped condenser coils allowing protection against hail. t Fast commissioning, as all units are systematically run tested before shipment. t Leak-tight refrigerant circuit and reduced maintenance costs. t Auto-adaptive control algorithm and automatic compressor unloading for increased and efficiency optimization. t Exceptional endurance tests for superior reliability. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP * Options available after official product launch. Please contact your sales representative for more information. ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 46 Touch Pilot operator interface 30RBM/30RBP Physical data 30RBM Air conditioning application as per EN14511-3 : 2013 kW Nominal cooling capacity* EER* kW/kW ESEER* kW/kW Standard unit sound power level dB(A) dB(A) Unit with option 15 sound power level dB(A) Unit with option 15LS sound power level kg Operating weight - standard unit ** Compressors / Circuits Compressors / Circuits Minimum capacity % Control Refrigerant kg Refrigerant charge** Condensers Fans Quantity Evaporator Dimensions Length Width Height mm mm mm 160 180 200 220 260 300 330 164 3.04 4.00 91 89 85 1220 180 3.14 4.01 91 89 85 1260 200 3.00 3.97 91 89 85 1270 217 3.00 3.95 92 90 86 1390 262 2.88 3.98 92 90 86 1410 297 2.97 4.00 93 91 86 1850 333 2.91 4.07 93 91 86 1890 1/2 33% 1/2 33% 1/2 33% 2/2 25% 2/2 25% 2/3 20% 400 430 470 520 363 2.95 4.00 93 92 87 2050 400 2.90 4.06 93 92 87 2110 432 2.96 4.07 94 93 88 2510 463 2.90 4.00 94 93 88 2530 528 2.90 4.04 94 93 88 2720 2/3 20% 3/3 17% 3/3 17% 3/4 14% 3/4 14% 4/4 13% 32.8 36.1 42.4 43.3 50.2 51.3 53.7 5 5 6 6 7 7 8 Y R A IN Prodialog Plus R410-a 20.7 23.8 25.1 25.1 26.2 All aluminium micro-channel heat exchanger (MCHE) Axial Flying Bird 4 with rotating shroud 3 4 4 4 4 Twin-circuit plate heat exchanger M I L E R P 2457 2253 2297 360 A T DA 3604 2253 2297 4798 2253 2297 * Preliminary performance data given at evaporator entering/leaving water temperature 12/7°C, outside air temperature 35°C. ** Unit weight and refrigerant charge shown are guidelines only. To find out values, please refer to the unit nameplate. 30RBP Air conditioning application as per EN14511-3 : 2013 kW Nominal cooling capacity* EER* kW/kW ESEER* kW/kW Standard unit sound power level dB(A) dB(A) Unit with option 15 sound power level dB(A) Unit with option 15LS sound power level kg Operating weight - standard unit ** Compressors / Circuits Compressors / Circuits Minimum capacity % Control Refrigerant kg Refrigerant charge** Condensers Fans Quantity Evaporator Dimensions Length Width Height mm mm mm 160 180 200 220 260 300 330 360 164 3.04 4.08 91 89 85 1260 180 3.14 4.09 91 89 85 1300 200 3.00 4.05 91 89 85 1300 217 3.00 4.07 92 90 86 1430 262 2.88 4.15 92 90 86 1450 297 2.97 4.20 93 91 86 1890 333 2.91 4.29 93 91 86 1920 363 2.95 4.20 93 92 87 2090 1/2 33% 1/2 33% 1/2 33% 2/2 25% 2/2 25% 2/3 20% 2/3 20% Prodialog Plus R410-a 20.7 23.8 25.1 25.1 26.2 All aluminium micro-channel heat exchanger (MCHE) Axial Flying Bird 4 with rotating shroud 3 4 4 4 4 Twin-circuit plate heat exchanger 2457 2253 2297 E R P 5 430 470 520 400 2.90 4.26 93 92 87 2140 432 2.96 4.36 94 93 88 2570 463 2.90 4.24 94 93 88 2590 528 2.90 4.31 94 93 88 2790 3/3 17% 3/3 17% 3/4 14% 3/4 14% 4/4 13% 36.1 42.4 43.3 50.2 51.3 53.7 5 6 6 7 7 8 Y R A IN M I L 32.8 400 3604 2253 2297 A T DA 4798 2253 2297 * Preliminary performance data given at evaporator entering/leaving water temperature 12/7°C, outside air temperature 35°C. ** Unit weight and refrigerant charge shown are guidelines only. To find out values, please refer to the unit nameplate. t"UUJNFPGQSJOUJOHUIJTDBUBMPHVFVOJUTBSFOPUZFUDFSUJmFEXJUIJOUIF&VSPWFOU-$1)1QSPHSBNTPEBUBTIPVMECFUSFBUFEBTQSFMJNJOBSZ t1SFMJNJOBSZEBUBJTQSPWJEFEGPSUIFQVSQPTFTPGFBSMZEFTJHOTJ[JOHBOEQIZTJDBMEJNFOTJPOJOH t$BSSJFSBTBOBDUJWFQBSUJDQBOUPG&VSPWFOU$FSUJmFE1FSGPSNBODF&$1 QSPHSBNTXJMMTVCNJUEBUBUPUIF&VSPWFOU$FSUJUB$FSUJmDBUJPO&$$ PODFEFWFMPQNFOUJTmOBMJ[FEBOEQSPEVDUTBSFBWBJMBCMFGPSNBSLFUMBVODI Operating range 30RBP Legend: Entering air temperature, °C Entering air temperature, °C 30RBM Leaving evaporator water temperature, °C Leaving evaporator water temperature, °C Standard unit operating at full load. Operating range, units equipped with options 28, 28B and 28C “Winter operation”. Option 28 (with variable-speed lead fan for each circuit) allows operation down to -20°C outside temperature. Option 28B, 28C (with two-speed lead fan for each circuit) allows operation down to -10°C outside temperature. In addition to options 28, 28B and 28C the unit must either be equipped with the evaporator frost protection option (for units without hydronic module option) or the evaporator and hydronic module frost protection option (for units with hydronic module option) or the water loop must be protected by the installer by adding a frost protection solution. 47 Notes: Evaporator ΔT = 5 K The evaporator is protected against frost down to -20°C. AIR-COOLED LIQUID CHILLERS Air conditioning 30XAS Options Features t .$)&DPJMTDPSSPTJPOQSPUFDUJPOT t $V"MDPJMTDPSSPTJPOQSPUFDUJPOT t 6OJUFRVJQQFEGPSBJSEJTDIBSHF ducting t *1DPOUSPMCPY t (SJMMFT t &ODMPTVSFQBOFMT t 8JOUFSPQFSBUJPO t &WBQPSBUPSBOEIZESPOJDNPEVMF frost protection t )FBUSFDMBJN t 4FSWJDFWBMWF t %JTDIBSHFWBMWF High-pressure dual-pump hydronic module t )JHIFOFSHZFóDJFODZWFSTJPO t +#VT#BD/FUPS-0/HBUFXBZT t &OFSHZ.BOBHFNFOUNPEVMF&.. t 3VTTJBOBOE"VTUSBMJBODPEF compliance t $PNQSFTTPSFODMPTVSF t 5SBEJUJPOBMDPJMTBOEUSBEJUJPOBMDPJMT without slots t 4VDUJPOQJQJOHJOTVMBUJPO t -PXBOEWFSZMPXTPVOEMFWFMT (second attenuation level) t .BTUFSTMBWFPQFSBUJPO t 8FMEFE7JDUBVMJDFWBQPSBUPSXBUFS connections t &WBQPSBUPSXJUIBMVNJOJVNKBDLFU t %VBMSFMJFGWBMWFXJUIJOTUBMMFE three-way valve t 'JWFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t *EFBMGPSJOEVTUSJBMBOEDPNNFSDJBMBQQMJDBUJPOTXJUIPQUJNBMQFSGPSNBODFT and maximum quality. t "WBJMBCMFJOUXPWFSTJPOTPOFXJUIWFSZMPXOPJTFMFWFMTBOETVQFSJPSFOFSHZ efficiency; the other with optimal energy efficiency to minimise operating costs. t &YUSFNFMZIJHIGVMMMPBEBOEQBSUMPBEFOFSHZFóDJFODJFT&VSPWFOUFOFSHZ efficiency class A to C, in accordance with EN14511-3: 2013. Standardised Eurovent values in accordance with EN 14511-3: 2013: EER up to 3.2 and ESEER up to 4. t 5XJOSPUPSTDSFXDPNQSFTTPSTXJUIIJHIFóDJFODZNPUPSBOEBWBSJBCMF capacity valve for exact matching of the cooling capacity to the load. t "MMBMVNJOJVNDPOEFOTFS.$)& XJUIIJHIFóDJFODZNJDSPDIBOOFMTBOE increased corrosion resistance. t 6TFPG3BSFGSJHFSBOUXJUI[FSPP[POFEFQMFUJPOQPUFOUJBMUIF microchannel condensers reduce the refrigerant charge by 30%. t -PXOPJTFUIHFOFSBUJPO'MZJOH#JSEGBOTNBEFPGDPNQPTJUFNBUFSJBM t 1SP%JBMPHDBQBDJUZDPOUSPMTZTUFN t 'MPPEFETIFMMBOEUVCFFWBQPSBUPSUPJODSFBTFIFBUFYDIBOHFFóDJFODZ t &DPOPNJ[FSTZTUFNXJUIFMFDUSPOJDFYQBOTJPOEFWJDFUPJODSFBTFDPPMJOHDBQBDJUZ t 7TIBQFDPOEFOTFSDPJMTBMMPXRVJFUFSBJSnPXBDSPTTUIFDPJM t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 6OJUTBSFSVOUFTUFECFGPSFTIJQNFOUBOEJODMVEFBRVJDLUFTUGVODUJPOGPS fast commissioning. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PNQSFIFOTJWFFOEVSBODFUFTUT t "RVBGPSDFPòFSTNVMUJQMFSFNPUFDPOUSPMNPOJUPSJOHBOEEJBHOPTUJDQPTTJCJMJUJFT \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 48 30XAS Physical data 30XAS Air conditioning application as per EN14511-3: 2013 Nominal cooling capacity, unit with option 279* Unit with options 279 and 119** EER, unit with option 279 EER, unit with options 279 and 119 Eurovent class, unit with option 279 Eurovent class, unit with options 279 and 119 ESEER, unit with option 279 ESEER, unit with options 279 and 119 Operating weight*** Unit with options 279 and 119 Compressor Refrigerant Capacity control Condensers Condenser fans Unit with options 279 and 119 Quantity kW kW kW/kW kW/kW kW/kW kg 242 282 342 442 482 232 245 2.76 2.97 C B 3.78 3.69 284 285 3.00 3.15 B A 3.93 3.69 334 345 3.08 3.24 B A 3.99 3.80 430 461 2.93 3.15 B A 3.87 3.75 467 486 2.87 3.09 C B 3.96 3.79 2390 2810 06T semi-hermetic screw compressor, 50 r/s R-134a, one refrigerant circuit PRO-DIALOG+, electronic expansion valve (EXV) All aluminium micro-channel heat exchanger Axial Flying Bird IV fans with rotating shroud 2870 3630 3720 4 6 7 8 20500/27083 23917/31597 27333/ 36111 5 Total air flow, unit with option 279/unit with options 279 and 119 l/s 13667/18055 17083/22569 Flooded shell-and-tube type Evaporator Colour code: RAL7035 Chassis paint colour Dimensions Length x depth x height mm 2410 x 2253 x 2297 3604 x 2253 x 2297 NOTE: For the conditions please refer to page 31. * Option 279 = compressor enclosure ** Option 119 = high energy efficiency. *** Weights are guidelines only. The refrigerant charge is also given on the unit nameplate. 4798 x 2253 x 2297 Electrical data 30XAS 242 282 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit A 303 388 Start-up current* Unit with options 279 and 119 kW 101/105 113/118 Maximum power input** A 165/172 185/194 Maximum current draw (Un)** * Instantaneous start-up current (locked rotor current in star connection of the compressor). ** Values obtained at operation with maximum unit power input. Values given on the unit name plate. 342 442 482 388 587 587 134/139 218/229 184/190 305/318 213/221 353/368 Note: Motor and fan electrical data if the unit operates at Eurovent conditions (motor ambient temperature 50°C): 1.9 A, start-up current: 8.4 A, power input: 760 W. Operating range High energy efficiency unit or option 119 Entering air temperature, °C Entering air temperature, °C Standard unit Evaporator leaving water temperature, °C Evaporator leaving water temperature, °C Legend Operating range, unirt equipped with option 28 "Winter operation" Below 0°C air temperature the unit must either be equipped with the evaporator frost protection option (41A or 41B), or the water loop must be protected against frost by using a frost protection solution (by the installer). Part load average 49 AIR-COOLED LIQUID CHILLERS Air conditioning 30XA Options Features t .$)&DPJMTDPSSPTJPOQSPUFDUJPOT t $V"MDPJMTDPSSPTJPOQSPUFDUJPOT t -PXWFSZMPXUFNQFSBUVSFHMZDPM solution t 6OJUFRVJQQFEGPSEJTDIBSHFEVDUJOH t *1DPOUSPMCPY t 5SPQJDBMBQQMJDBUJPOT t (SJMMFTBOEFODMPTVSFQBOFMT t 8JOUFSPQFSBUJPO t &WBQPSBUPSBOEIZESPOJDNPEVMF frost protection t )FBUSFDMBJN t 4JOHMFQPXFSDPOOFDUJPOQPJOU t 4FSWJDFEJTDIBSHFWBMWF t &WBQPSBUPSXJUIPOFQBTTNPSFPSMFTT t CBSFWBQPSBUPS t 3FWFSTFEXBUFSDPOOFDUJPOT t -PXPSIJHIQSFTTVSFTJOHMFPS dual-pump hydronic module t %JSFDUFYQBOTJPOGSFFDPPMJOHTZTUFN t )JHIFOFSHZFóDJFODZWFSTJPO t +#VT.PE#VT#BD/FU-0/HBUFXBZT t &OFSHZ.BOBHFNFOUNPEVMF&.. t 1SP%JBMPH5PVDI4DSFFO t %VBMTBGFUZWBMWFJOTUBMMFEXJUI three-way valve t #VJMUUP4XJTT3VTTJBO"VTUSBMJBODPEFT t 5SBEJUJPOBMDPJMT t *OTVMBUJPOPOFWBQPSBUPSFOUFSJOH leaving refrigerant lines t -PXBOEWFSZMPXTPVOEMFWFM t .BTUFSTMBWFPQFSBUJPO t $PNQSFTTPSFODMPTVSF t 8FMEFE7JDUBVMJDFWBQPSBUPSXBUFS connections t &WBQPSBUPSXJUIBMVNJOJVNKBDLFU t 5XFOUZGPVSTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t 5IFJEFBMTPMVUJPOGPSJOEVTUSJBMBOEDPNNFSDJBMBQQMJDBUJPOTXJUIPQUJNBM performances and maximum quality. Units designed to operate up to 55°C. t &YDFQUJPOBMGVMMMPBEBOEQBSUMPBEFOFSHZFóDJFODZ&VSPWFOUFOFSHZFóDJFODZ class A and B (unit with high-efficiency option 119); standardised Eurovent values in accordance with EN 14511-3: 2013: EER up to 3.3 and ESEER up to 4.2. t "WBJMBCMFJOUXPWFSTJPOTPOFXJUIWFSZMPXOPJTFMFWFMTBOETVQFSJPSFOFSHZ efficiency; the other with optimal energy efficiency to minimise operating costs. t 5XJOSPUPSTDSFXDPNQSFTTPSTXJUIIJHIFóDJFODZNPUPSBOEBWBSJBCMF capacity valve for exact matching of the cooling capacity to the load. t "MMBMVNJOJVNDPOEFOTFS.$)& XJUIIJHIFóDJFODZNJDSPDIBOOFMTBOEIJHI corrosion resistance. t 6TFPG3BSFGSJHFSBOUXJUI[FSPP[POFEFQMFUJPOQPUFOUJBMUIFNJDSPDIBOOFM heat exchangers reduce the refrigerant charge by 30%. t -PXOPJTFUIHFOFSBUJPO'MZJOH#JSEGBOTNBEFPGDPNQPTJUFNBUFSJBM t 1SP%JBMPHDPOUSPMTZTUFN t 'MPPEFETIFMMBOEUVCFFWBQPSBUPS t &DPOPNJ[FSTZTUFNXJUIFMFDUSPOJDFYQBOTJPOEFWJDFUPJODSFBTFDPPMJOHDBQBDJUZ t 7TIBQFDPOEFOTFSDPJMTBMMPXRVJFUFSBJSnPXBDSPTTUIFDPJM t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 6OJUTBSFSVOUFTUFECFGPSFTIJQNFOUBOEJODMVEFBRVJDLUFTUGVODUJPOGPSGBTU commissioning. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PNQSFIFOTJWFFOEVSBODFUFTUT t "RVBGPSDFPòFSTNVMUJQMFSFNPUFDPOUSPMNPOJUPSJOHBOEEJBHOPTUJDQPTTJCJMJUJFT \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface (standard) 50 Pro-Dialog Touch Screen operator interface (option) 30XA Physical data 30XA 252 302 Air conditioning application as per EN14511-3: 2013 kW 267 291 Nominal cooling capacity, unit with option 279* Unit with options 279 and 119** kW 273 298 EER, unit with option 279 kW/kW 3.00 2.96 EER, unit with options 279 and 119 kW/kW 3.13 3.10 Eurovent class, unit with option 279 B B Eurovent class, unit with options 279 & 119 A A ESEER, unit with option 279 kW/kW 3.94 4.20 ESEER, unit with options 279 and 119 kW/kW 3.89 3.96 Operating weight*** 3410 3450 Unit with options 279 and 119 kg Dimensions Length, standard unit mm mm Depth + height Refrigerant Compressors Control Condensers Fans Quantity, standard unit - option 119* Evaporator NOTE: For the conditions, please refer to page 31. 352 402 452 502 602 702 752 802 852 902 1002 1102 1112 1202 1212 1302 1312 1352 1382 1402 1502 1702† 318 378 426 473 601 654 691 759 807 875 960 1119 1107 1216 1218 1294 1285 1383 1377 1436 1443 1611 325 2.98 3.09 B B 4.20 4.01 391 3.08 3.21 B A 4.10 3.88 442 2.89 3.08 C B 4.13 3.93 499 2.93 3.15 B A 4.09 3.93 612 3.03 3.13 B A 4.08 3.84 679 3.11 3.31 A A 4.10 4.07 723 2.91 3.08 B B 4.00 3.87 785 2.88 3.10 C A 4.06 3.92 841 2.98 3.24 B A 4.09 4.03 886 2.91 3.12 B A 3.81 3.82 976 2.95 3.09 B B 3.82 3.74 1147 3.02 3.24 B A 4.05 4.08 1144 3.04 3.27 B A 3.89 4.00 1235 2.96 3.09 B B 3.93 3.93 1247 3.09 3.23 B A 4.08 4.10 3490 4313 4883 4814 5707 5857 6157 6457 6958 7258 7836 9590 9410 10020 9570 1317 2.87 3.09 C B 3.88 4.00 1326 2.91 3.16 B A 3.61 3.89 1437 2.64 3.09 D B 3.69 4.03 1433 2.77 3.06 C B 3.54 3.91 1480 2.97 3.20 B A 3.95 3.98 1525 2.87 3.19 C NA 3.85 3.97 1682 3.00 3.22 NA NA 3.81 3.87 10410 10180 10770 10270 3953 3953 6958 7776 7926 6958 3604 3604 3604 4798 4798 5992 7186 7186 7186 7186 8380 8380 9574 11962 11962 11962 11962 11962 11962 11962 11962 9574 9574 8380 4798 4798 8380 2253 x 2297 R-134a 06T semi-hermetic screw compressors, 50 r/s Pro-Dialog, electronic expansion valve (EXV) Aluminium micro-channel heat exchangers Axial Flying Bird 4 fans with rotating shroud 6 6 6 8 8 9 11 12 12 12 14 14 16 19 19 20 20 20 20 20 20 24 24 28 Flooded shell-and-tube type † These models are not Eurovent certified, as they are out of Eurovent certification program scope. * Option 279 = compressor enclosure ** Option 119 = high energy efficiency *** Weights are guidelines only. The values for sizes 1402, 1502 and 1702 are for modules 1 and 2. Note: Unit sizes 30XA 1402 to 1702 are supplied in two field-assembled modules. Electrical data 30XA 252 302 352 402 452 502 602 702 752 802 852 902 1002 1102 1112 1202 1212 1302 1312 1352 1382 1402 1502 1702 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit Max. start-up current, circuits A + B/C + D* Unit with option 279 A 269 269 287 402 505 505 574 606 773 803 805 893 941 574/587 587/772 773/587 587/772 803/587 772/772 891/587 772/772 893/587 941/587 805/805 Unit with option 279 A 274 274 292 407 510 510 583 616 782 812 815 905 954 583/587 587/772 782/587 587/772 812/587 772/772 901/587 772/772 905/587 954/587 815/815 and 119 Max. power input, circuits A + B/C + D** Unit with option 279 kW 121 131 141 165 185 204 247 267 293 312 343 359 420 247/210 182/279 293/210 211/302 342/210 258/278 388/209 278/299 390/210 420/210 343/343 Unit with option 279 kW 126 136 147 172 192 212 257 278 304 323 356 372 435 257/217 186/286 304/217 216/309 353/217 262/284 400/216 284/305 405/217 435/217 356/356 and 119 Max. unit current draw, circuits A + B/C + D** Unit with option 279 A 198 215 233 270 303 335 404 436 492 522 572 611 707 404/354 313459 492/354 359/496 568/354 426/456 655/352 456/491 661/354 707/354 572/572 Unit with option 279 A 208 226 243 284 316 350 423 457 512 542 596 635 734 423/367 321/470 512/367 367/508 588/367 436/466 678/364 466/501 688/367 734/367 596/596 and 119 * Instantaneous start-up current (operating current of the smallest compressor + fan current + locked rotor current in star connection of the largest compressor). Values obtained at operation with maximum unit power input. ** Values obtained at operation with maximum unit power input. Values given on the unit name plate. Circuit D for size 1702 only. Note: Unit sizes 30XA 1102 to 1702 have two power connection points (circuits A + B and circuits C + D). Operating range 30XA 30XA unit with option 119 Legend Air entering temperature, °C Air entering temperature, °C Operating range, unit equipped with option 28 (winter operation) Evaporator leaving water temperature, °C Below 0°C air temperature the unit must either be equipped with the evaporator frost protection option (41A or 41B), or the water loop must be protected against frost by using a frost protection solution (by the installer). Part load average Evaporator leaving water temperature, °C 51 AIR-COOLED LIQUID CHILLERS Air conditioning 30XAV Options Features t &.$DMBTTJmDBUJPOBDDPSEJOHUP*&$ 61800-3 class C2 t -PXOPJTFMFWFM t .$)&BOUJDPSSPTJPOQSPUFDUJPOT t &WBQPSBUPSXJUIBMVNJOJVNKBDLFU t #BD/FUPWFS*1DPOOFUJPO t +CVT#BD/FU-0/HBUFXBZT t &OFSHZ.BOBHFNFOU.PEVMF t (SJMMFTBOEFODMPTVSFQBOFMT t 4FSWJDFWBMWFT t &WBQPSBUPSXJUIPOFQBTTMFTT t CBSFWBQPSBUPS t %VBMTBGFUZWBMWFT t 8FMEFE7JDUBVMJDFWBQPSBUPSXBUFS connections t t t t t t t t t %FTJHOFEGPSDPNNFSDJBMBOEJOEVTUSJBMBQQMJDBUJPOT )JHIQFSGPSNBODF$BSSJFSHSBOUFEBUGVMMBOEQBSUJBMMPBE /FX506$)1*-05TNBSUDPOUSPMXJUIJOUVJUJWFBOEVTFSGSJFOEMZJOUFSGBDF (SFFOTQFFEUFDIOPMPHZCPUIPODPNQSFTTPSTBOEGBOTBMMPXTQSFDJTF capacity matching of building load changes and significantly reduce unit power input, especially at part loads. &YDMVTJWFJOWFSUFSESJWFOTDSFXDPNQSFTTPSTBOFWPMVUJPOPGUIFQSPWFO Carrier fixed-speed screw compressor design. 7BSJBCMFTQFFEGBOTDPOUSPMMFEUPNJOJNJ[FOPJTFBOEFOFSHZDPOTVNQUJPOBU all conditions. 0QFSBUJPOHSBOUFEVQUP¡$PVUEPPSBJSUFNQFSBUVSF *NQSPWFEFMFDUSJDBMQFSGPSNBODF)JHIQPXFSGBDUPSBOEOFHMJHJCMFJOSVTI current. *OEFQFOEFOUBOEMFBLUJHIUSFGSJHFSBOUDJSDVJUT Touch Pilot operator interface 52 30XAV Physical data 30XAV Air conditioning application as per EN14511-3: 2013 Nominal cooling capacity* EER* ESEER* Sound power level, standard unit Sound power level, unit with option 279** Sound power level, unit with options 257 and 279 ** Operating weight *** Dimensions Length Width Height Compressor Compressors / Circuits Minimum capacity Control Refrigerant Refrigerant charge*** Condenser 500 600 700 kW kW/kW kW/kW dB(A) dB(A) dB(A) kg 509 3.20 4.46 102 99 96 4901 611 3.20 4.55 103 100 97 5264 695 3.14 4.50 103 100 97 5865 mm mm mm 6192 6192 7386 8380 2253 2253 2253 2253 2297 2297 2297 2297 Variable speed, inverter-driven screw compressor (06T, Carrier proprietary technology) 2/2 2/2 2/2 2/2 10 10 10 10 Touch Pilot, with 7'' touch screen R134a 93 106 116 131 All aluminium micro-channel heat exchanger (MCHE) A T DA 819 3.33 4.74 103 100 97 6524 IN M I L % kg Y AR 800 E R P Variable speed, inverter-driven axial fans (Flying Bird 4, Carrier proprietary technology) 9 10 12 14 Flooded, shell-and-tube type Fans Quantity Evaporator 30XAV range will extend up to 1200 kW. Contact Carrier sales force for more details. * ** *** Preliminary performance data given at evaporator entering/leaving water temperature 12/7°C, outside air temperature 35°C Option 279 = compressor enclosure. Option 257 = low sound option Unit weight and refrigerant charge shown are guidelines only. To find out values, please refer to the unit nameplate. NOTE: t At time of printing this catalogue, units are not yet certified within the Eurovent LCP-HP program so data should be treated as preliminary t Preliminary data is provided for the purposes of early design sizing and physical dimensioning t Carrier, as an active particpant of Eurovent Certified Performance (ECP) programs, will submit data to the Eurovent Certita Certification (ECC) once development is finalized and products are available for market launch Operating range 30XAV Operating MAP (option 257) 50 50 40 40 30 Entering air temperature, °C Outdoor air temperature, °C 30XAV Operating MAP Standard unit 20 10 0 -10 30 20 10 0 -10 -20 2 7 12 -20 17 2 Evaporator leaving water temperature, °C ° 7 12 Evaporator leaving water temperature, °C MAP - PL (All Unit Sizes) MAP - PL (30XAV0500 Only) MAP - FL MAP - PL (All Unit Sizes) MAP - PL (30XAV0500 Only) MAP - FL Below 0°C air temperature the unit must either be equipped with the evaporator frost protection option (41A), or the water loop must be protected against frost by using a frost protection solution (by the installer) 53 17 WATER-COOLED/CONDENSERLESS LIQUID CHILLERS Air conditioning 30WG/30WGA Options Features t 7FSZMPXUFNQFSBUVSFHMZDPMTPMVUJPO (30WG) t 4PGUTUBSUFS t .BTUFSTMBWFPQFSBUJPO t &YUFSOBMEJTDPOOFDUIBOEMF t $POEFOTFSJOTVMBUJPO8( t -PXPSIJHIQSFTTVSFmYFEPS variable-speed single-pump hydronic module, evaporator side t -PXPSIJHIQSFTTVSFmYFEPS variable-speed single-pump hydronic module, condenser side (30WG) t +#VT#BD/FUBOE-0/HBUFXBZT t 4QFDJmDDPPMJOHDPOUSPM t -PXTPVOEMFWFM t 6OJUTUBDLBCMF t $VTUPNFSXBUFSDPOOFDUJPOBUUIF top of the unit (30WG) t &WBQPSBUPS8(8(" BOE condenser (30WG) screw or welded connection sleeves t 3FNPUFVTFSJOUFSGBDF t &MFWFOTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOEFYDFQUJPOBMMZ high ESEER values. t /FXHFOFSBUJPOPGMJRVJEDIJMMFSTEFTJHOFEGPSDPNNFSDJBMPóDFTIPUFMTFUD residential (houses, apartments etc.) or industrial applications (low-temperature cooling). t 8(VOJUTPòFS&VSPWFOUFOFSHZFóDJFODZDMBTT#BOEBO&4&&3PGPWFS 5.5 for dual-compressor units - one of the highest in its category. t $POEFOTFSMFTTWFSTJPOQPTTJCMF8(" XJUISFNPUFDPOEFOTFSDPOUSPMCPY available as an option. t 3"SFGSJHFSBOUBOETDSPMMDPNQSFTTPST t $PNQBUJCMFXJUI$BSSJFSTFSJFTESZDPPMFSTSFNPUFDPOEFOTFST t 6OJRVFDPNCJOBUJPOPGIJHIQFSGPSNBODFBOEGVODUJPOBMJUZJOBO exceptionally compact chassis. t 6OJUTJODMVEFBVUPNBUJDDPOEFOTJOHQSFTTVSFDPOUSPMWJBUISFFXBZWBMWFGPS optimised operation, even at low outside temperature. t 3FWFSTJCJMJUZCZXBUFSnPXJOWFSTJPOJOUIFTZTUFN t 1SP%JBMPHDPOUSPMBOEDPNQBUJCJMJUZXJUIUIF"RVBTNBSUTZTUFN t 6OJUTBWBJMBCMFXJUIDPOOFDUJPOTBUUIFUPQPSBUUIFSFBS t &BTZJOTUBMMBUJPOTNBMMGPPUQSJOUJEFBMGPSSFGVSCJTIFECVJMEJOHTBMMPXTBDDFTT in very tight plant rooms. t 5IFWBSJBCMFXBUFSnPX78' UFDIOPMPHZPGUIFWBSJBCMFnPXQVNQPQUJNJTFT system operation and enhances energy efficiency. t 4UBOEBSEMPXTPVOEMFWFMBMMPXTJOTUBMMBUJPOJOBOZCVJMEJOHUZQF \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 54 30WG/30WGA Physical data 30WG/30WGA 020 025 030 Air conditioning application as per EN14511-3: 2013 - 30WG kW 24.6 28.7 31.5 Nominal cooling capacity kW 4.72 4.72 4.69 EER Eurovent class B B B ESEER kW/kW 5.10 5.09 5.03 Part load performance ESEER kW/kW 5.35 5.35 5.30 Air conditioning application as per EN14511-3: 2013 - 30WGA kW 22.6 27.0 29.5 Nominal cooling capacity kW 3.75 3.84 3.87 EER kg 191/164 200/171 200/171 Operating weight 30WG/30WGA* Hermetic scroll 48.3 r/s Compressors Quantity 1 1 1 Number of capacity stages 1 1 1 Minimum capacity % 100 100 100 Dimensions, standard unit** Width x depth x height mm 600 x 1044 x 901 R-410A Refrigerant* Pro-Dialog+ Control Direct-expansion plate heat exchanger Evaporator Plate heat exchanger Condenser (30WG only) 035 040 045 050 060 070 080 090 36.7 4.73 B 5.05 5.32 41.8 4.69 B 5.03 5.32 46.6 4.72 B 5.07 5.36 58.1 4.72 B 5.83 6.31 63.4 4.65 B 5.90 6.38 73.8 4.69 B 5.79 6.30 83.9 4.65 B 5.99 6.54 94.6 4.68 B 5.93 6.44 34.7 3.93 207/177 39.2 3.94 212/180 43.7 3.90 220/185 53.7 3.82 386/321 59.8 3.85 392/324 69.2 3.86 403/332 78.3 3.91 413/339 87.8 3.88 441/354 1 1 100 1 1 100 1 1 100 2 2 50 2 2 50 2 2 50 2 2 50 2 2 50 880 x 1474 x 901 NOTE: For the conditions, please refer to page 31. 30WGA performance are given for an equivalent refrigerant piping length (without filter drier and valves) of 3 m. * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. ** The dimensions shown are for the standard unit. For other unit types please refer to the dimensional drawings. Electrical data 30WG/30WGA Power circuit Nominal voltage Control circuit supply Maximum start-up current draw (Un)* Standard unit, 30WG Standard unit, 30WGA Unit with electronic starter option, 30WG Unit with electronic starter option, 30WGA Maximum operating power input, 30WG** Maximum operating power input, 30WGA** Maximum operating current draw (Un), 30WG*** Maximum operating current draw (Un), 30WGA*** * ** *** 020 025 030 V-ph-Hz 400-3-50 ± 10% 24 V, via internal transformer A A A A kW kW A A 98 98 53.9 53.9 9.1 8.7 15.6 14.7 142 142 78.1 78.1 10.7 10.2 18.7 17.7 142 142 78.1 78.1 11.7 11.3 19.8 19.3 035 040 045 050 060 070 080 090 147 147 80.9 80.9 13.6 12.5 23.2 21.7 158 158 86.9 86.9 15 14.2 25.4 24.1 197 197 108.4 108.4 17 16.1 29 27.5 163 160.7 100.1 96.8 21.4 20.4 37.4 35.4 165 161.8 102.1 97.9 23.4 22.6 39.6 38.7 174 170.2 108.9 104.1 27.2 25.0 46.4 43.5 188 183.4 117.9 112.3 30 28.5 50.8 48.1 233 226 144.4 137.4 34 32.2 58 55.0 Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Maximum power input at the unit operating limits. Maximum unit operating current at maximum unit power input and 400 V. Operating range 30WGA 65 65 60 60 55 Condensing temperature, °C Condenser leaving water temperature, °C 30WG 50 45 40 Option 6 Standard 35 30 25 20 55 50 45 Medium temperature application 40 Standard 35 30 25 15 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 20 8 10 12 14 16 18 20 -2 Evaporator leaving water temperature, °C 30WG standard unit 30WG unit with option 6 (brine) Option 6: Very low-temperature glycol solution 0 2 4 6 8 10 12 14 Evaporator leaving water temperature, °C 30WGA standard unit 30WGA unit for medium temperature application (% glycol < 25%) 55 16 18 20 WATER-COOLED/CONDENSERLESS LIQUID CHILLERS WITH INTEGRATED HYDRONIC MODULE Air conditioning 30RW Options Features t )JHIQSFTTVSFTJOHMFPSEVBMQVNQ evaporator t $POEFOTFSIZESPOJDNPEVMFXJUI variable-speed single or dual pump t )FBUQVNQIPUXBUFSDPOUSPM t &MFDUSPOJDTUBSUFSGPSSFEVDFETUBSU up current t 34DPNNVOJDBUJPOTBOEi$$/ Clock Board” time schedule board t 7FSZMPXUFNQFSBUVSFHMZDPMTPMVUJPO down to -10°C t 'JFMEXBUFSDPOOFDUJPOTBUUIFVOJU top t 5FOTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t "RVBTOBQDIJMMFSTXJUITDSPMMDPNQSFTTPSTEJHJUBMBVUPBEBQUJWF1SP%JBMPH control and ozone-friendly refrigerant HFC-407C. t $BOCFTVQQMJFEXJUIJOUFHSBUFEIZESPOJDFWBQPSBUPSBOEDPOEFOTFSNPEVMFT limiting the installation to simple operations such as the entering and leaving water piping connection. t *OUFMMJHFOUDPOUSPMPGDPOEFOTFSXBUFSQVNQTQFFEBOEPQFSBUJPOPGHMZDPM cooler (30RW) or air-cooled condenser fans (30RWA) to ensure reliable and economical operation. t 2VJDLFMFDUSJDBMDPOOFDUJPOT t 6OJUTDBOPQFSBUFEPXOUP¡$PVUTJEFUFNQFSBUVSF t 5IFWBSJBCMFTQFFEDPOEFOTFSXBUFSQVNQBVUPNBUJDBMMZBEKVTUTUIFXBUFS flow rate to maintain the ideal condensing conditions. t )JHIQFSGPSNBODFQMBUFIFBUFYDIBOHFSTNBYJNJTFUIFUIFSNPEZOBNJD properties of refrigerant HFC-407C. From size 30RW 160 the evaporator and the condenser have two interlaced refrigerant circuits. t 4QBDFTBWJOHEFTJHO t /PQMBOUSPPNSFRVJSFEoVOJUDBOCFJOTUBMMFEJOBQMBDFUIBUJTPQFOUPUIF public, if local regulations permit. t 5IFSFGSJHFSBOUDJSDVJUJTDPNQMFUFMZMFBLQSPPG t 6TFEXJUI$BSSJFSTFSJFTHMZDPMDPPMFSTPSBJSDPPMFEDPOEFOTFSTTVQQMJFE ready for installation with a control box. All control components are installed and tested in the factory. A A Pro-Dialog Plus operator interface 56 30RW/RWA Physical data 30RW/RWA Air conditioning application as per EN14511-3: 2013 - 30RW kW Nominal cooling capacity EER kW/kW Eurovent class ESEER kW/kW Air conditioning application as per EN14511-3: 2013 - 30RWA kW Nominal cooling capacity EER kW/kW Operating weight 30RW unit without pump kg 30RWA unit without pump kg Extra weight 30RW: single evaporator pump (option 116B) kg 30RWA: single evaporator pump (option 116B) 30RW/RWA: dual evaporator pump (option 116C) kg 30RW: single condenser pump (option 270B) kg 30RW: dual condenser pump (option 270C) kg Dimensions (length x depth x height) Standard unit with or without hydronic module mm Unit with hydronic module (options 116B, 116C, 270B, 270C) mm Refrigerant* 30RW Compressors 30RW/30RWA Control Condensers (30RW) Hydronic condenser module (30RW) Condenser pump Evaporator (30RW/30RWA) Hydronic evaporator module (30RW/30RWA) Evaporator pump Water connections (30RW/30RWA) Field refrigerant connections (30RWA) 110 120 135 150 160 185 210 245 275 300 110 125 142 152 165 186 219 251 288 315 4.06 3.92 4.01 3.93 4.51 4.24 4.38 4.25 4.36 4.32 D D D D C D C C C C 4.79 4.56 4.74 4.66 5.36 5.06 5.17 5.01 5.27 5.15 109 125 142 152 160 184 212 243 282 309 4.05 4.01 4.10 4.02 4.09 4.08 4.00 3.92 4.09 4.12 864 937 956 977 1079 1144 1357 1471 1557 1557 773 836 845 855 948 996 1159 1273 1311 1311 15 15 15 15 245 245 245 245 245 245 15 15 15 15 245 245 245 285 285 285 130 130 130 130 300 300 358 358 358 358 80 80 80 80 250 250 265 265 265 265 140 140 140 140 310 310 368 368 368 368 2300 x 922 x 1963 2950 x 922 x 1993 R-407C Hermetic scroll, 48.3 r/s Pro-Dialog Plus Welded plate heat exchangers, max. water-side operating pressure with hydronic module 1000 kPa, without hydronic module 400 kPa Removable screen filter, variable-speed water pump, expansion tank, safety valve, pressure gauge, and purge valve Single or twin-head composite centrifugal pump, according to option used, variable speed by frequency converter (48.3 r/s) Welded direct-expansion plate heat exchanger, max. water-side operating pressure with hydronic module 1000 kPa, without hydronic module 400 kPa Removable screen filter, water pump, expansion tank, water flow switch, safety valve, pressure gauge, purge valve and control valve Single or twin-head composite centrifugal pump, according to option used (48.3 r/s) Victaulic** Welded copper tube NOTE: For the conditions, please refer to page 31. * ** The RWA units only have a nitrogen holding charge. With tubular sleeve, supplied with the unit, consisting of a Victaulic connection at one end and a plain section at the other end. Electrical data 30RW/RWA (without hydronic module) 110 120 135 150 160 185 210 245 275 300 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% The control circuit is supplied via the unit-mounted transformer Control circuit supply Maximum unit power input, 30RW + 30RWA* kW 42.4 48.8 54.0 59.1 63.2 72.2 84.9 97.6 107.9 118.2 A 48.1 54.0 61.0 68.0 71.7 84.2 96.1 108.0 122.0 136.0 Nominal unit current draw 30RW** A 51.4 58.0 64.7 71.4 76.3 89.6 102.8 116.0 129.4 142.8 Nominal unit current draw 30RWA*** Maximum start-up current, (standard unit without electronic starter) A 245.2 254.0 309.0 318.0 212.6 245.7 314.5 332.0 396.0 414.0 30RW + 30RWA† Maximum start-up current, (electronic-starter option) A 159.2 168.0 201.0 210.0 158.6 183.7 228.5 246.0 288.0 306.0 30RW + 30RWA‡ * Power input of the compressor(s) at maximum unit operating conditions: entering/leaving evaporator water temp. 15°C/10°C, maximum condensing temp. 65°C, and 400 V nominal voltage. ** Nom. unit current draw at standard conditions: evaporator entering/leaving water temp. 12°C/7°C, condenser entering/leaving water temp. 30°C/35°C. The current values are given at 400 V nom. voltage. *** Nom. unit current draw at standard conditions: evaporator entering/leaving water temp. 12°C/7°C, saturated condensing temp. (dew point) 45°C, subcooling 5 K. The current values are given at 400 V nom. voltage. † Max. instantaneous starting current at 400 V nom. voltage and with compressor in across-the-line start (max. operating current of the smallest compressor(s) + locked rotor current of the largest compressor). ‡ Max. instantaneous starting current at 400 V nom. voltage and with compressor with electronic starter (max. operating current of the smallest compressor(s) + reduced start-up current of the largest compressor). 57 WATER-COOLED SCREWCOMPRESSOR LIQUID CHILLERS Air conditioning 30HXC Options Features t -PXUFNQFSBUVSFCSJOFTPMVUJPO t 6OJUTVQQMJFEJOUXPBTTFNCMFE parts t BOEQPXFS supply t &WBQPSBUPSQVNQBOEDPOEFOTFS pump electrical power/control circuit t $PNQSFTTPSTVDUJPOWBMWF t &WBQPSBUPSPSDPOEFOTFSXJUIPOF pass less t &WBQPSBUPSPSDPOEFOTFSNBYJNVN water-side operating pressure of 21 bar t +#VT.PE#VT#BD/FU-0/HBUFXBZT t &MFDUSPOJDDPNQSFTTPSTUBSUFS (30HXC 200-375) t &MFDUSJDBMQSPUFDUJPOUP*1$ t )JHIDPOEFOTJOHUFNQFSBUVSFVOJU and non-reversible heat pump t 3FWFSTFEFWBQPSBUPSPSDPOEFOTFS water inlet/ outlet t 5SPQJDBMJTFEDPOUSPMCPY t 7BSJPVTDPOEFOTJOHUFNQFSBUVSF options t %VBMEJTDIBSHFWBMWFJOTUBMMFEXJUI three-way valve t 34DPNNVOJDBUJPOJOUFSGBDF with open protocol t $PEFDPNQMJBODFGPS4XJU[FSMBOE and Russia t 8BUFSDPOOFDUJPOLJUGPSXFMEFE or screwed evaporator and/or condenser connections t t t t t t t t t t t t 4FWFOUFFOTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 1SP%JBMPH1MVTDPOUSPMUPPQUJNJTFUIFFóDJFODZPGUIFSFGSJHFSBOUDJSDVJU 0[POFGSJFOEMZ)'$BSFGSJHFSBOUQSPWFOOPOUPYJDOPOnBNNBCMF &RVJQQFEXJUITDSFXDPNQSFTTPSTGPSFYUSFNFMZRVJFUPQFSBUJPOBOEMPX vibration levels. $POUSPMJTGVMMZBVUPNBUJDBOEJODMVEFTBVUPEJBHOPTUJDT 5XPJOEFQFOEFOUSFGSJHFSBOUDJSDVJUT .VMUJQMFDPNQSFTTPSDPODFQU 4FSJFTTUBSEFMUBTUBSUFSMJNJUJOHUIFTUBSUVQDVSSFOUPO)9$ &BTZJOTUBMMBUJPODPNQBDUEFTJHOmUTUISPVHIBTUBOEBSEEPPSPQFOJOH Supplied as a complete package for easy installation. No extra controls, timers, starters or other items to install. 4JOHMFQPXFSQPJOU)9$UP BOEPOFQPXFSQPJOUQFSDJSDVJU (30HXC 200 to 375). 4JNQMFUPTFSWJDFNFDIBOJDBMMZDMFBOBCMFFWBQPSBUPSBOEDPOEFOTFSUXJO screw compressors with minimum routine service. 7FSZMPXUFNQFSBUVSFPQUJPOBWBJMBCMFGPSQBSUPGUIFSBOHFBMMPXT evaporator leaving water temperatures down to -10ºC. A A Pro-Dialog Plus operator interface 58 Carrier twin-screw compressor 30HXC Physical data 30HXC 080 090 100 110 120 130 Air conditioning application as per EN14511-3: 2013 kW 287 312 349 375 413 450 Nominal cooling capacity EER kW/kW 5.04 4.80 4.85 4.57 4.86 4.69 Eurovent class B B B C B B ESEER kW/kW 5.56 5.41 5.31 5.28 5.23 5.21 kg 2274 2279 2302 2343 2615 2617 Operating weight Dimensions, standard unit Depth mm 2558 2558 2558 2565 3275 3275 Length mm 980 980 980 980 980 980 Height mm 1800 1800 1800 1850 1816 1816 R-134a Refrigerant 06N semi-hermetic twin-screw compressor Compressors Quantity - Circuit A 1 1 1 1 1 1 Quantity - Circuit B 1 1 1 1 1 1 Capacity control Pro-Dialog Plus control No. of control steps 6 6 6 6 6 6 Shell and tube with internally finned copper tubes Evaporator Water connections Victaulic Inlet/outlet in 4 4 4 5 5 5 Shell and tube with internally finned copper tubes Condenser Water connections Victaulic Inlet/outlet in 5 5 5 5 5 5 NOTE: For the conditions, please refer to page 31. 140 155 175 190 200 230 260 285 310 345 375 510 4.72 B 5.17 2702 542 4.55 C 4.85 2712 599 4.68 B 5.03 3083 652 4.72 B 4.97 3179 701 4.74 B 5.08 3873 814 4.73 B 5.06 4602 899 4.45 C 5.01 4656 986 4.76 B 5.11 4776 1109 4.76 B 5.49 5477 1207 4.55 C 5.39 5553 1302 4.65 B 5.34 5721 3275 980 1816 3275 980 1816 3275 980 1940 3275 980 1940 3903 1015 1980 3924 1015 2060 3924 1015 2060 3924 1015 2060 4533 1015 2112 4533 1015 2112 4533 1015 2112 1 1 1 1 1 1 1 1 2 1 2 1 2 1 2 1 2 2 2 2 2 2 6 6 6 6 8 8 8 8 10 10 10 5 5 5 5 6 6 6 6 8 8 8 5 5 6 6 6 8 8 8 8 8 8 140 155 175 190 200 230 260 285 310 345 375 Not applicable to high condensing temperature units - please refer to electronic selection catalogue. Electrical data 30HXC 080 090 100 110 120 130 Power circuit Nominal power supply (Un)* V-ph-Hz 400-3-50 ± 10% The control circuit is supplied via the factory-installed transformer Control circuit supply Nominal current drawn* A 101 115 127 143 149 168 190 207 226 234 255 294 337 354 399 448 477 Maximum starting current*** A 181 206 223 249 267 298 333 355 382 442 841 978 1027 1200 1129 1184 1373 Circuit A** A - - - - - - - - - - 712 822 871 1028 844 871 1028 844 871 1028 Circuit B** A 605 715 715 856 * Standard Eurovent conditions: Evaporator entering/leaving water temperature 12°C and 7°C. Condenser entering/leaving water temperature 30°C/35°C. ** Maximum unit operating current at maximum unit power input. *** Maximum instantaneous starting current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced starting current of the largest compressor). Operating range 58 Notes: 1. Evaporator and condenser ΔT = 5 K 2. For start-up at full load with a condenser water entering temperature below 20°C, a three-way valve must be used to maintain the correct condensing temperature 3. Maximum condenser water leaving temperature 50°C (at full load) A Standard unit operating at full load. B Standard unit operating at reduced load. C Units operating with head pressure control with analogue water control valve. For transient operating modes (start-up and part load) the unit can operate down to a condenser entering water temperature of 13°C. Additional operating range for high condensing temperature units and non-reversible heat pumps. Condenser water entering temperature, °C 50 B 45 35 30 A 25 20 C 15 13 4 5 10 13 15 20 Evaporator leaving water temperature, °C 59 WATER-COOLED LIQUID CHILLERS Air conditioning 30XW Options/accessories Features t .FEJVNBOEMPXUFNQFSBUVSF applications* (down to -12°C possible) t 6OJUTVQQMJFEJOUXPBTTFNCMFEQBSUT t /PEJTDPOOFDUTXJUDICVUXJUITIPSU circuit protection t 4JOHMFQPXFSDPOOFDUJPOQPJOU t &WBQPSBUPSDPOEFOTFSQVNQFMFDUSJDBM power/control circuit options t 4FSWJDFWBMWFTFU t &WBQPSBUPSDPOEFOTFSBSSBOHFNFOU with one pass t $POEFOTFSJOTVMBUJPO t CBSFWBQPSBUPSBOEDPOEFOTFS t 3FWFSTFEFWBQPSBUPSBOEDPOEFOTFS water connections t +#VT#BD/FUBOE-0/HBUFXBZT t 7BSJPVTDPOEFOTJOHUFNQFSBUVSF options t &OFSHZ.BOBHFNFOU.PEVMF&.. t $PEFDPNQMJBODFGPS4XJU[FSMBOE and Australia t .BTUFSTMBWFPQFSBUJPO t 5PVDI4DSFFOJOUFSGBDF t -PXOPJTFMFWFME#" DPNQBSFE to standard unit) t 5IFSNBMDPNQSFTTPSJOTVMBUJPO t 8BUFSDPOOFDUJPOLJUGPSXFMEFE or flanged evaporator/condenser connections t 5XFOUZTUBOEBSEFóDJFODZTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPN to 1732 kW and eleven high-efficiency sizes with nominal cooling capacities from 509 to 1756 kW. t %FTJHOFEGPSJOEVTUSJBMBOEDPNNFSDJBMBQQMJDBUJPOTUIBUSFRVJSFPQUJNBM performances and maximum quality. t 5XPWFSTJPOT98GPSBJSDPOEJUJPOJOHBOESFGSJHFSBUJPOBQQMJDBUJPOTBOE 30XWH for heating applications (see separate entry). t 5XPFóDJFODZDMBTTFTUIFTUBOEBSEFóDJFODZ98PòFSTBOPQUJNJTFECBMBODF of technical and economical aspects and superior energy efficiency; the highefficiency 30XW-P offers unequalled energy efficiency at minimised operating cost. t &YDFQUJPOBMGVMMMPBEBOEQBSUMPBEFOFSHZFóDJFODZ&VSPWFOUFOFSHZFóDJFODZ class “A”, EER of up to 6.15 kW/kW and ESEER of up to 8.0 kW/kW (30XW-P) t 5XJOSPUPSTDSFXDPNQSFTTPSTXJUIIJHIFóDJFODZNPUPSBOEBWBSJBCMF capacity valve for exact matching of the cooling capacity to the load. t 6TFPG3BSFGSJHFSBOUXJUI[FSPP[POFEFQMFUJPOQPUFOUJBM t 1SP%JBMPHDPOUSPMTZTUFN t 'MPPEFENFDIBOJDBMMZDMFBOBCMFIFBUFYDIBOHFST t &DPOPNJ[FSTZTUFNXJUIFMFDUSPOJDFYQBOTJPOEFWJDFGPSJODSFBTFEDPPMJOH capacity (30XW-P). t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 6OJUTBSFSVOUFTUFECFGPSFTIJQNFOUBOEJODMVEFBRVJDLUFTUGVODUJPOGPS fast commissioning. t -FBLUJHIUSFGSJHFSBOUDJSDVJUUXPJOEFQFOEFOUSFGSJHFSBOUDJSDVJUTGSPNL8 upwards. t $PNQSFIFOTJWFFOEVSBODFUFTUT t "RVBGPSDFPòFSTNVMUJQMFSFNPUFDPOUSPMNPOJUPSJOHBOEEJBHOPTUJDQPTTJCJMJUJFT * Only sizes 512/562/1012/1152 \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 60 Touch-screen Pro-Dialog operator interface {option) 30XW Physical data Standard-efficiency units 30XW-254 304 354 402 452 552 602 652 702 802 852 1002 1052 Air conditioning application as per EN14511-3: 2013 kW Nominal cooling capacity 273 307 359 459 473 532 538 677 730 792 839 1017 1060 EER kW/kW 5.32 5.30 5.24 5.21 5.35 5.21 5.17 5.39 5.30 5.19 5.39 5.26 5.20 Eurovent class A A A A A A A A A A A A A ESEER part-load performance kW/kW 5.67 5.58 5.58 5.75 5.77 5.78 5.66 6.06 6.02 5.79 5.94 6.3 6.34 kg Operating weight* 2017 2036 2072 2575 2575 2613 2644 3247 3266 3282 3492 5370 5408 Dimensions Depth mm 928 928 928 936 936 936 936 1040 1040 1040 1042 1036 1036 Length mm 2724 2724 2724 2741 2741 2741 2741 3059 3059 3059 2780 4025 4025 Height mm 1567 1567 1567 1692 1692 1692 1692 1848 1848 1848 1898 1870 1870 High-efficiency units 30XW-P 512 562 712 812 862 1012 1162 Air conditioning application as per EN14511-3: 2013 kW 509 577 737 786 861 1039 1157 Nominal cooling capacity kW/kW 5.71 EER 5.64 5.83 5.62 5.65 5.73 5.78 Eurovent class A A A A A A A kW/kW 6.09 ESEER 6.14 6.41 6.24 6.17 6.74 6.83 kg Operating weight* 2981 3020 3912 3947 3965 6872 6950 Dimensions Depth mm 936 936 1069 1069 1069 1039 1039 Length mm 3059 3059 3290 3290 3290 4730 4730 Height mm 1743 1743 1950 1950 1950 1997 1997 Physical data for all units Semi-hermetic 06T screw compressors, 50 r/s Compressors R-134a Refrigerant Pro-Dialog, electronic expansion valves (EXV) Capacity control Flooded multi-pipe type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections Evaporator Flooded multi-pipe type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections Condenser 1154 1252 1352 1452 1552† 1652† 1702† 1141 5.30 A 6.23 5698 1257 5.69 A 6.73 7066 1342 5.51 A 6.44 7267 1453 5.36 A 6.27 7305 1547 5.29 NA 6.06 7337 1036 1156 4025 4730 1925 2051 1314 1156 4730 2051 1464 1156 4730 2051 1156 4730 2051 1612† 1657 5.67 NA 6.62 8681 1732 5.68 NA 6.56 8699 1902 1902 4790 4790 1515 1515 1762† 1323 5.80 A 6.65 7542 1452 5.58 A 6.36 7752 1626 5.87 NA 6.80 10910 1756 5.79 NA 6.59 10946 1162 4730 2051 1162 4730 2051 2129 4832 1562 2129 4832 1562 NOTE: For the conditions please refer to page 31. † These models are not Eurovent certified, as they are out of Eurovent certification program scope. * Weights are guidelines only. The refrigerant charge is given on the unit nameplate. Electrical data Standard-efficiency units 30XW-Nominal power supply, all units Control circuit, all units Maximum start-up current* Circuit A Circuit B Maximum power input** Circuit A Circuit B Maximum current drawn (Un)** Circuit A Circuit B High-efficiency units 30XW-P Maximum start-up current* Circuit A/B Maximum power input** Circuit A/B Maximum current drawn (Un)** Circuit A/B * ** 254 304 354 402 452 V-ph-Hz 400-3-50 ± 10% 24 V via the built-in transformer 552 602 652 702 802 852 1002 1052 1154 1252 1352 1452 1552 1652 1702 A A 233 - 233 - 303 - 414 - 414 - 414 - 414 - 587 - 587 - 587 - 587 - 414 414 414 414 414 414 587 414 587 587 587 587 587 587 587 587 587 587 kW kW 76 - 89 - 97 - 128 - 135 - 151 - 151 - 184 - 200 - 223 - 223 - 150 135 151 151 151 151 184 151 184 184 200 200 223 223 223 202 223 223 A A 123 512 145 - 160 562 206 - 217 712 242 - 242 - 242 217 1162 242 242 242 242 1314 295 242 812 295 317 862 295 295 1464 317 351 317 351 1612 351 351 317 351 1762 A 414/- 414/- 587/- 587/- 587/- 414/414 414/414 587/414 587/587 587/587 587/587 kW 135/- 151/- 184/- 200/- 223/- 134/134 151/151 184/151 184/184 200/200 223/223 A 217/- 242/- 295/- 317/- 351/- 217/217 242/242 295/242 295/295 317/317 351/351 Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at operation with maximum unit power input. Values obtained at operation with maximum unit power input. Values given on the unit name plate. Operating range, standard units Operating range, option 150 From approx. 45% to full load Part load limit approx. 35% Minimum load limit approx. 15% 55 50 Condenser leaving water temperature, °C Condenser leaving water temp., °C 351 351 1012 45 40 35 30 25 20 15 0 5 10 15 20 Evaporator leaving water temp., °C 70 From approx. 60% to full load Part load limit approx. 50% Minimum load limit approx. 30% 65 60 55 50 45 40 35 30 25 20 0 5 10 15 20 Evaporator leaving water temperature, °C 61 WATER-COOLED LIQUID CHILLERS Air conditioning 30XW-V Options Features t $POEFOTFSJOTVMBUJPO t 4FSWJDFWBMWFTFU t &WBQPSBUPSDPOEFOTFSQVNQFMFDUSJDBM power/control circuit options t &WBQPSBUPSBOEPSDPOEFOTFSXJUI one pass t CBSFWBQPSBUPSBOEPSDPOEFOTFS t 3FWFSTFEFWBQPSBUPSBOEPS condenser water connections t +#VT#BD/FUPS-0/HBUFXBZT t "EEJUJPOBMNPEVMFGPSDPNNVOJDBUJPO with BacNet protocol via Ethernet (IP) t $POEFOTJOHUFNQFSBUVSFMJNJUBUJPO t $POUSPMGPSMPXDPOEFOTJOH temperature systems t &OFSHZ.BOBHFNFOU.PEVMF&.. t -FBLEFUFDUJPO t $PEFDPNQMJBODFGPS4XJU[FSMBOE and Australia t -PXOPJTFMFWFME#" DPNQBSFE to standard unit) t 8FMEFEFWBQPSBUPSBOEPSDPOEFOTFS water connection kit t 'MBOHFEFWBQPSBUPSBOEPSDPOEFOTFS water connection kit t 5IFSNBMDPNQSFTTPSJOTVMBUJPO t &.$DMBTTJmDBUJPOBDDPSEJOHUP*&$ 61800-3 - class C2 t .BTUFSTMBWFPQFSBUJPO t 4JOHMFQPXFSDPOOFDUJPOQPJOU (1150-1710) t /JOFTJ[FTGPSDPNNFSDJBMBOEJOEVTUSJBMBQQMJDBUJPOTXJUIOPNJOBMDPPMJOH capacities from 587 to 1741 kW. t 5IFVOJUTGFBUVSFFYDMVTJWFJOWFSUFSESJWFOTDSFXDPNQSFTTPSTBOFWPMVUJPO of the proven traditional Carrier twin-rotor screw compressor design. t 987VOJUTBSFEFTJHOFEGPSIJHIQFSGPSNBODFCPUIBUGVMMMPBEBOEBU part load with EERs up to 5.5 and ESEERs up to 8.0 (EN14511-3: 2013) and Eurovent energy class ratings A and B. t /FXJOOPWBUJWF5PVDI1JMPUTNBSUDPOUSPMGPSWBSJBCMFESJWFTDSFXDPNQSFTTPS units uses an intuitive, user-friendly interface with concise, clear information in a choice of languages. t $PNQMJBODFXJUI*&$DMBTT$ t *OWFSUFSESJWFOUXJOSPUPSTDSFXDPNQSFTTPSTBMMPXQSFDJTFDBQBDJUZNBUDIJOH of building load changes and significantly reduce unit power input, especially at part load. t 'MPPEFENFDIBOJDBMMZDMFBOBCMFIFBUFYDIBOHFST t $PNQBDUEFTJHOBOETJNQMJmFEFMFDUSJDBMBOEXBUFSDPOOFDUJPOTGPSFBTZ installation. t 3BSFGSJHFSBOUXJUI[FSPP[POFEFQMFUJPOQPUFOUJBM t -FBLUJHIUSFGSJHFSBOUDJSDVJUUXPJOEFQFOEFOUSFGSJHFSBOUDJSDVJUTGSPNL8 upwards. t .JOJNJTFEPQFSBUJOHTPVOEMFWFMBUQBSUMPBE t *NQSPWFEFMFDUSJDBMQFSGPSNBODF Touch Pilot operator interface 62 30XW-V Physical data 30XW-V 580 630 810 880 1150 1280 Air conditioning/cooling floor application as per EN14511-3 : 2013 Condition 1 kW 587 652 812 858 1140 1305 Cooling capacity EER kW/kW 5.44 5.31 5.25 5.07 5.45 5.50 Eurovent class, cooling A A A A A A ESEER kW/kW 7.80 7.60 8.04 7.76 7.79 7.59 Condition 2 kW 791 846 1023 970 1528 1688 Cooling capacity EER kW/kW 6.96 6.50 6.22 5.63 6.85 6.64 Eurovent class, cooling A A A A A A kg 3152 3190 4157 4161 7322 7398 Operating weight* Dimensions Length x depth x height mm 3059 x 1087 x 1743 3290 x 1237 x 1950 4730 x 1164 x 1997 Semi-hermetic 06T screw compressor, 60 r/s Compressor Quantity, circuit A/B 1/1/1/1/1/1 1/1 Touch Pilot, inverter-driven compressor. electronic expansion valve (EXV) Capacity control Minimum capacity % 20 20 20 20 10 10 R-134a Refrigerant* Multi-tube type flooded Evaporator Multi-tube type Condenser 1470 1570† 1710† 1461 5.38 A 7.30 1604 5.05 NA 7.15 1741 4.94 NA 6.85 1703 5.99 A 7574 2093 6.00 A 7770 2273 6.00 A 7808 4730 x 1255 x 2051 1/1 1/1 1/1 10 10 10 NOTE: For the conditions please refer to page 31. † These models are not Eurovent certified, as they are out of Eurovent certification program scope. * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30XW-V Power circuit Nominal voltage Control circuit supply Start-up current* Maximum power factor Maximum power input, circuit A/B*** Eurovent current draw, circuit A/B** Maximum current draw (Un), circuit A/B*** * ** *** 580 V-ph-Hz kW A A 630 810 880 400-3-50 ± 10% 24 V, via internal transformer Negligible (lower than maximum current drawn) 0.91-0.93 0.91-0.93 0.91-0.93 0.91-0.93 155/193/222/246/175/200/240/265/270/330/380/421/- 1150 1280 1470 1570 1710 0.91-0.93 155/155 175/175 270/270 0.91-0.93 193/193 200/200 330/330 0.91-0.93 222/193 240/200 380/330 0.91-0.93 222/222 240/240 380/380 0.91-0.93 246/246 265/265 421/421 Instantaneous start-up current Eurovent unit operating conditions: evaporator entering/leaving water temperature 12°C/7°C, condenser entering/leaving water temperature 30°C/35°C. Values obtained at operation with maximum unit power input. Values given on the unit name plate. Operating range Condenser leaving water temperature, °C 55 From approximately 50% to full load Part-load limit approximately 50% Minimum load limit 50 45 40 35 30 25 20 15 0 5 10 15 20 Evaporator leaving water temperature, °C 63 HIGH-EFFICIENCY CHILLERS WITH SCREW COMPRESSORS Air conditioning 23XRV Control CCN - Carrier Comfort Network Features t 5IF937&WFSHSFFOSBOHFPòFSTTVQFSJPSTPMVUJPOTXJUISFDPSEDBQBDJUJFT from 970 to 1880 kW, EERs up to 6.5 and ESEERs up to 10.0. t *OOPWBUJWFUSJQMFSPUPSTDSFXDPNQSFTTPSEFTJHOUIBUGFBUVSFTBCBMBODFE rotor geometry and shorter screw lengths. t 7BSJBCMFGSFRVFODZESJWFDPNQSFTTPSUPNBYJNJTFNBDIJOFFOFSHZFóDJFODZ Achieves ultra-high efficiency levels whilst lowering the cost of ownership. t $PNCJOBUJPOPGUIFSFMJBCJMJUZPGBTDSFXDPNQSFTTPSXJUIUIFFOFSHZTBWJOHT of a variable-frequency drive (VFD). t 6OQBSBMMFMFEPQFSBUJPOBMFOWFMPQFUIBUQFSNJUTUIFDIJMMFSUPPQFSBUFVOEFS real-world adverse conditions. t *EFBMGPSCPUIOFXDPOTUSVDUJPOBOESFQMBDFNFOUVTJOHFOWJSPONFOUBMMZ sound refrigerant (R-134a) at superior efficiency and with powerful controls. t .JYNBUDIDBQBCJMJUZXJUIXJEFSBOHFPGIFBUFYDIBOHFSTGPSVOJUQFSGPSNBODF optimisation. 23XRV units are equipped with unique triple-rotor screw compressor technology 64 23XRV Dimensions Heat exchanger size 30 to 32 35 to 37 40 to 42 45 to 47 50 to 52 55 to 57 Length A One pass 4350 4870 4496 5017 4521 5042 mm mm mm mm mm mm Two passes 4172 4693 4347 4867 4382 4902 Three passes 4350 4870 4420 4940 4432 4953 Width B Height C 1930 1930 2045 2045 2127 2127 2200 2200 2299 2299 2305 2305 Evaporator tubes C Condenser tubes B A Micro-grooved heat exchanger tubes to ensure optimised heat exchange between the refrigerant and the heat exchange medium. New generation screw compressor Hermetic motor, cooled by suction gas Variable-frequency drive with active filtering Cooling ensured by refrigerant Reduced length triple rotor for increased compression 65 AIR-COOLED CONDENSERS/ FLUID COOLERS Air conditioning ADAGIO 09AD Options/accessories Features t .VMUJQMFDJSDVJUT t )PSJ[POUBMEJTDIBSHF t &YUSBIJHIGFFUTJ[FT UPDPNQMZ with specific site configurations t 4QFDJBMmOTQBDJOHT t .PVOUFEFMFDUSJDBMQBOFM t &NFSHFODZTXJUDI t 4QFDJBMNPUPSTTFMFDUFENPEFMT t 'BOJTPMBUPSTXJUDI t 4VCDPPMJOHDJSDVJUTWFSUJDBMBJS flow only) t 4UBJOMFTTTUFFMTDSFXT t &$.PUPSTGPSTJHOJmDBOUFOFSHZ savings (fans 630 mm diameter) t .PUPSQPXFSTVQQMJFT7QI 50 Hz and 400 V-3 ph-60 Hz. t "MUFSOBUJWFmONBUFSJBMTGPSTBMJOF and polluted atmospheres - Copper tubes/aluminium fins with vinyl coating - Copper tubes/aluminium fins with a wide choice of anti-corrosion coatings such as Blygold to suit site conditions t 5IF"%"(*0SFNPUFDPOEFOTFSTDPWFSBDBQBDJUZSBOHFGSPN 6 to 316 kW designed for commercial use in refrigeration and air conditioning applications. All models are available with vertical or horizontal air flow. t 5IF"%"(*0'$ESZDPPMFSTDPWFSBDBQBDJUZSBOHFGSPNUPL8GPSVTF in commercial and industrial applications, working with fluids that are copper compatible. All models are available with vertical or horizontal air flow. t 5IF"%"(*0SBOHFJTEFTJHOFEGPSPVUEPPSJOTUBMMBUJPOGPSNBYJNVNXPSLJOH temperature of 55°C. t 4FWFSBMGBOTDPOmHVSBUJPOQPTTJCMFUPNBUDIDPPMJOHDBQBDJUZBOETPVOE requirements. t 4JOHMFPSEPVCMFSBXTDPJMTUPNBUDIQSFTTVSFESPQTSFRVJSFNFOU t $BTJOHJOHBMWBOJTFETIFFUTUFFMSFTJTUJOH67SBEJBUJPOBOEPòFSJOHFYDFMMFOU corrosion protection. t 5IFQSPQFMMFSGBOTFOTVSFBTJHOJmDBOUTPVOESFEVDUJPOXIJMFNBJOUBJOJOH high air flow performances. Motors have high-efficiency shrouds to reduce sound levels and increase the air flow efficiency. t "MMDPOEFOTFSTBOEnVJEDPPMFSTBSF&VSPWFOUDFSUJmFEFYDMVEJOHSFNPUF condensers with R410A, which are out of the scope of Eurovent Certification program) and tested by independent laboratories in accordance with European Standards. The performances comply with EN 327 for air-cooled condensers and EN 1048 for fluid coolers. t %SZDPPMFSTBSFTVJUBCMFGPSDPPMJOHXBUFSPSPUIFSnVJETUIBUEPOPUDPSSPEF with copper. t &MFDUSJDBMDPOOFDUJPOTJOXFBUIFSQSPPGCPYFTFBTZBDDFTTGPSNBJOUFOBODF t "JSDPPMFEDPOEFOTFSTBSFBWBJMBCMFXJUISFGSJHFSBOU3B3$3" and R-404A. t 5IFTPVOEQPXFSMFWFMTBSFJOBDDPSEBODFXJUI*40BOE*40 66 09AD/09FCAD Note: Contact Carrier for selections. ADAGIO covers a capacity range from 5 to 300 kW. Fan data Asynchronous Motors Diameter Number of poles 4P 500 mm 6P 8P 4P 600 mm 6P Δ Y Δ Y Δ Y Δ Y Δ Power input (kW) 0.67 0.52 0.24 0.18 0.13 0.09 1.04 0.76 0.54 Full load current (A) 1.31 0.94 0.63 0.31 0.31 0.16 2.3 1.4 1.2 L Y 0.38 0.65 Speed Wiring Power input (kW) 0.83 0.56 0.47 0.28 0.24 0.13 0.09 0.06 0.02 Full load current (A) 1.5 1.1 0.85 0.55 0.45 0.28 0.23 0.19 0.16 0.01 0.16 Speed* Wiring H L H L H L H L H * H: High, L: Low EC-Motors Diameter 630 mm Number of poles NA 1140 1000 930 750 700 540 455 380 200 NA 155 67 AIR-COOLED CONDENSERS/ FLUID COOLERS Air conditioning TENOR 09TE Options/accessories Features t t t t t t t t t 5IF5&/03SFNPUFDPOEFOTFSTDPWFSBDBQBDJUZSBOHFGSPNUPL8 and are designed for commercial and industrial use in refrigeration and air conditioning applications. t 5IF5&/03'$ESZDPPMFSTDPWFSBDBQBDJUZSBOHFGSPNUPL8GPSVTF in commercial and industrial applications, working with fluids that are copper compatible. t 5IF5&/03SBOHFJTEFTJHOFEGPSPVUEPPSJOTUBMMBUJPOGPSNBYJNVNXPSLJOH temperature of 60°C and outdoor air temperature from -30°C to +45°C. t 4FWFSBMGBOTDPOmHVSBUJPOQPTTJCMFUPNBUDIDPPMJOHDBQBDJUZBOETPVOE requirements. t $BTJOHJOHBMWBOJTFETIFFUTUFFMQPXEFSQBJOUFEQPMZFTUFSSFTJTUJOH67 radiation and offering excellent corrosion protection. t 5IFQSPQFMMFSGBOTFOTVSFBTJHOJmDBOUTPVOESFEVDUJPOXIJMFNBJOUBJOJOH high air flow performances. Motors have high-efficiency shrouds to reduce sound levels and increase the air flow efficiency and are designed to work with frequency speed control from 50 to 20 Hz. t "MMDPOEFOTFSTBOEnVJEDPPMFSTBSF&VSPWFOUDFSUJmFEBOEUFTUFECZ independent laboratories in accordance with European Standards. The performances comply with EN 327 for air-cooled condensers and EN 1048 for fluid coolers. t %SZDPPMFSTBSFTVJUBCMFGPSDPPMJOHXBUFSPSPUIFSnVJETUIBUEPOPUDPSSPEF with copper. t &MFDUSJDBMDPOOFDUJPOTJOXFBUIFSQSPPGCPYFTFBTZBDDFTT t "JSDPPMFEDPOEFOTFSTBSFBWBJMBCMFXJUISFGSJHFSBOU3B3$BOE R-404A. t 5IFTPVOEQPXFSMFWFMTBSFJOBDDPSEBODFXJUI*40BOE*40 t t t t .VMUJQMFDJSDVJUT 4QFDJBMmOTQBDJOHT .PVOUFEFMFDUSJDBMQBOFM &NFSHFODZTXJUDI 4QFDJBMNPUPSTTFMFDUFENPEFMT 'BOJTPMBUPSTXJUDI 4UBJOMFTTTUFFMTDSFXT 5XPTQFFEDPOOFDUJPOTGPSUIF motors &$NPUPSTGPSTJHOJmDBOUFOFSHZ savings .PUPSQPXFSTVQQMJFT7QI 50 Hz and 400 V-3 ph-60 Hz. )JHIFSNPUPSJOTVMBUJPOGPSBNCJFOU temperatures above 45°C "MUFSOBUJWFmONBUFSJBMTGPSTBMJOF and polluted atmospheres - Copper tubes/aluminium fins with vinyl coating - Copper tubes/aluminium fins with a wide choice of anti-corrosion coatings such as Blygold to suit site conditions 68 09TE/09FCTE Physical data Models Single row 09-TE90 2MSB 09-TE90 3MSB 09-TE90 4MSB 09-TE90 5MSB 09-TE90 6MSB 09-TE90 7MSB Double row 09-TE90 4MDB 09-TE90 6MDB 09-TE90 8MDB 09-TE90 10MDB 09-TE90 12MDB 09-TE90 14MDB 09-TE90 16MDB Fans/poles Fan arrangement 6PH (Delta) CAP AF kW l/s 6PL (Star) Lw/Lpa CAP AF dB(A) kW l/s 8PH (Delta) Lw/Lpa CAP AF dB(A) kW l/s 8PL (Star) Lw/Lpa CAP AF dB(A) kW l/s 12PH (Delta) Lw/Lpa CAP AF dB(A) kW l/s 12PL (Star) Lw/Lpa CAP AF dB(A) kW l/s Lw/Lpa dB(A) 1 x 2 - ø900 1 x 3 - ø900 1 x 4 - ø900 1 x 5 - ø900 1 x 6 - ø900 1 x 7 - ø900 238 357 477 597 717 836 15483 23225 30967 38708 46450 54192 90/58 92/60 93/61 94/62 95/63 96/63 201 301 402 502 603 704 12083 18125 24167 30208 36250 42292 84/52 86/54 87/55 88/56 89/57 90/57 186 279 372 465 559 652 11194 16792 22389 27986 33583 39181 83/51 85/53 86/54 87/55 88/56 89/56 154 231 308 385 463 540 8561 12842 17122 21403 25683 29964 76/44 78/46 79/47 80/48 81/49 82/49 136 204 272 340 408 476 7189 10783 14378 17972 21567 25161 71/39 73/41 74/42 75/43 76/44 77/44 106 159 212 265 318 371 5236 7729 10306 12882 15458 18035 62/30 64/32 65/33 66/34 67/35 68/35 2 x 2 - ø900 2 x 2 - ø900 2 x 2 - ø900 2 x 3 - ø900 2 x 3 - ø900 2 x 3 - ø900 2 x 4 - ø900 399 599 800 1001 1201 1400 1602 27475 41213 54950 68688 82425 96163 109900 93/61 95/63 96/64 97/65 98/65 99/66 99/66 335 502 670 838 1006 1173 1341 21142 31713 42283 52854 63425 73996 84567 87/55 89/57 90/58 91/59 92/59 93/60 93/60 326 489 653 817 980 1145 1308 20375 30563 40750 50938 61125 71313 81500 86/54 88/56 89/57 90/58 91/58 92/59 92/59 258 387 517 646 776 905 1035 14686 22029 29372 36715 44058 51401 58744 79/47 81/49 82/50 83/51 84/51 85/52 85/52 227 341 455 569 684 798 912 12561 18842 25122 31403 37683 43964 50244 74/42 76/44 77/45 78/46 79/46 80/47 80/47 175 263 351 439 527 615 703 8753 13129 17506 21882 26258 30635 35011 65/33 67/35 68/36 69/37 70/37 71/38 71/38 CAP - Nominal capacity AF - Air flow Lw - Sound power level Lpa - Sound pressure level at 10 m Note: Performance data given for units with AC-motor fans, 400-3-50 power supply, refrigerant R-404A, Δt1 =15 K, operating pressure 26 bar, ENV327. For performance data for units with other refrigerants or fans, and for 09FCTE 90 dry coolers, see technical documentation or electronic selection program. Fan data Correction factors for different refrigerants Asynchronous Motors Diameter 900 mm Number of poles Speed* Wiring 6P H H L H L Δ Δ Y Δ Y 8P 12P Power input Full load (kW) current (A) 2.2 5.3 1.3 3.5 0.8 1.7 0.5 1.5 0.25 0.65 Temperature difference ΔT, K Refrigerant 8 10 12 0.67 0.80 R-404A – R-22 – R-134a – R-507 0.53 0.46 0.62 0.77 R-407C, R-407A 15 1.00 1.00 17 1.13 1.15 20 1.33 1.38 ‘* H: High, L: Low Diameter 910 mm 910 mm Number of poles NA NA Speed (rpm) 1000 910 750 690 560 610 560 470 330 200 Wiring NA NA Power input (kW) 3.12 2.26 1.28 1.01 0.56 0.6 0.45 0.26 0.1 0.04 Full load current (A) 4.9 3.5 2.0 1.7 1.1 1.2 0.9 0.6 0.3 0.2 2209 EC-Motors A 2200 Single-row models Models 09TE 90 2MSB 09TE 90 3MSB 09TE 90 4MSB 09TE 90 5MSB 09TE 90 6MSB 09TE 90 7MSB 09TE 90 4MDB 09TE 90 6MDB 09TE 90 8MDB 09TE 90 10MDB 09TE 90 12MDB 09TE 90 14MDB 09TE 90 16MDB Max. length A, mm 2465 3590 4715 5840 6965 8090 2465 3590 4715 5840 6965 8090 9215 Net weight, kg 469 691 872 1072 1273 1472 882 1301 1650 2018 2390 2785 3256 1636 Dimensions and weights A Double-row models 69 1200 AIR-COOLED CONDENSERS/ FLUID COOLERS Air conditioning ALTO 09AL Options/accessories Features t .VMUJQMFDJSDVJUT t )PSJ[POUBMEJTDIBSHF t &YUSBIJHIGFFUTJ[FT UPDPNQMZ with specific site configurations t 4QFDJBMmOTQBDJOHT t .PVOUFEFMFDUSJDBMQBOFM t &NFSHFODZTXJUDI t 4QFDJBMNPUPSTTFMFDUFENPEFMT t 'BOJTPMBUPSTXJUDI t 4VCDPPMJOHDJSDVJUTWFSUJDBMBJS flow only) t 4UBJOMFTTTUFFMTDSFXT t &$.PUPSTGPSTJHOJmDBOUFOFSHZ savings t .PUPSQPXFSTVQQMJFT7QI 50 Hz and 400 V-3 ph-60 Hz. t )JHIFSNPUPSJOTVMBUJPOGPSBNCJFOU temperatures above 45°C t 5XPTQFFEDPOOFDUJPOTGPSUIF motors t "MUFSOBUJWFmONBUFSJBMTGPSTBMJOF and polluted atmospheres - Copper tubes/aluminium fins with vinyl coating - Copper tubes/aluminium fins with a wide choice of anti-corrosion coatings such as Blygold to suit site conditions t 5IF"-50SFNPUFDPOEFOTFSTDPWFSBDBQBDJUZSBOHFGSPN 24 to 1128 kW designed for commercial and industrial use in refrigeration and air conditioning applications. All models are available with vertical or horizontal air flow. t 5IF"-50'$ESZDPPMFSTDPWFSBDBQBDJUZSBOHFGSPNUPL8GPSVTF in commercial and industrial applications, working with fluids that are copper compatible. All models are available with vertical or horizontal air flow. t 5IF"-50SBOHFJTEFTJHOFEGPSPVUEPPSJOTUBMMBUJPOGPSNBYJNVNXPSLJOH temperature of 60°C and outdoor air temperature from -30°C to +45°C. t 4FWFSBMGBOTDPOmHVSBUJPOTQPTTJCMFUPNBUDIDPPMJOHDBQBDJUZBOETPVOE requirements. t 4JOHMFPSEPVCMFSBXTDPJMTUPNBUDIQSFTTVSFESPQTSFRVJSFNFOUT t $BTJOHJOHBMWBOJTFETIFFUTUFFMQPXEFSQBJOUFEQPMZFTUFSSFTJTUJOH67SBEJBUJPO and offering excellent corrosion protection. t 5IFQSPQFMMFSGBOTFOTVSFBTJHOJmDBOUTPVOESFEVDUJPOXIJMFNBJOUBJOJOH high air flow performances. Motors have high-efficiency shrouds to reduce sound levels and increase the air flow efficiency and are designed to work with frequency speed control from 50 to 20 Hz. t "MMDPOEFOTFSTBOEnVJEDPPMFSTBSF&VSPWFOUDFSUJmFEBOEUFTUFECZ independent laboratories in accordance with European Standards. The performances comply with EN 327 for air-cooled condensers and EN 1048 for fluid coolers. t %SZDPPMFSTBSFTVJUBCMFGPSDPPMJOHXBUFSPSPUIFSnVJETUIBUEPOPUDPSSPEF with copper. t &MFDUSJDBMDPOOFDUJPOTJOXFBUIFSQSPPGCPYFTFBTZBDDFTTGPSNBJOUFOBODF t "JSDPPMFEDPOEFOTFSTBSFBWBJMBCMFXJUISFGSJHFSBOU3B3$BOE R-404A. t 5IFTPVOEQPXFSMFWFMTBSFJOBDDPSEBODFXJUI*40BOE*40 70 09AL/09FCAL Physical data Fans/poles Fan arrangement 06PH (Delta) CAP AF kW l/s 06PL (Star) Lw/Lpa CAP AF dB(A) kW l/s 08PH (Delta) Lw/Lpa CAP AF dB(A) kW l/s 08PL (Star) Lw/Lpa CAP AF dB(A) kW l/s 12PH (Delta) Lw/Lpa CAP AF dB(A) kW l/s 12PL (Star) Lw/Lpa CAP AF dB(A) kW l/s Lw/Lpa Models dB(A) Single row 1 x 3 - ø900 224 19571 92/60 190 15050 86/54 182 14025 85/53 153 10771 78/46 131 8617 73/41 102 6142 64/32 09AL 91 3MSC 1 x 3 - ø900 273 22458 92/60 231 17279 86/54 214 15400 85/53 178 11825 78/46 152 9625 73/41 119 6875 64/32 09AL 91 3MSD 1 x 3 - ø900 326 23833 92/60 275 18333 86/54 253 16225 85/53 207 12467 78/46 180 10358 73/41 138 7379 64/32 09AL 91 3MSE 1 x 4 - ø900 299 26094 93/61 253 20067 87/55 242 18700 86/54 204 14361 79/47 175 11489 74/42 136 8189 65/33 09AL 91 4MSC 1 x 4 - ø900 364 29944 93/61 308 23039 87/55 285 20533 86/54 237 15767 79/47 202 12833 74/42 158 9167 65/33 09AL 91 4MSD 1 x 4 - ø900 434 31778 93/61 366 24444 87/55 337 21633 86/54 276 16622 79/47 240 13811 74/42 184 9839 65/33 09AL 91 4MSE 1 x 5 - ø900 373 32618 94/61 316 25083 88/56 303 23375 87/55 255 17951 80/48 218 14361 75/43 170 10236 66/34 09AL 91 5MSC 1 x 5 - ø900 455 37431 94/60 385 28799 88/55 356 25667 87/54 296 19708 80/47 253 16028 75/42 198 11458 66/33 09AL 91 5MSD 1 x 5 - ø900 543 39722 94/60 458 30556 88/55 421 27042 87/54 344 20778 80/47 300 17264 75/42 230 12299 66/33 09AL 91 5MSE 1 x 6 - ø900 448 39142 95/63 379 30100 89/57 363 28050 88/56 306 21542 81/49 262 17233 76/44 203 12283 67/35 09AL 91 6MSC 1 x 6 - ø900 546 44917 95/62 482 34558 89/56 427 30800 88/55 355 23650 81/48 303 19250 76/43 237 13750 67/34 09AL 91 6MSD Double row 300 26094 93/61 254 20067 87/55 252 18700 86/54 204 14361 79/47 176 11489 74/42 136 8189 65/33 09AL 91 4MDC 2 x 2 - ø900 364 29944 93/61 308 23039 87/55 286 20533 86/54 238 15767 79/47 202 12833 74/42 158 9167 65/33 09AL 91 4MDD 2 x 2 - ø900 2 x 2 - ø900 434 31778 93/61 366 24444 87/55 338 21633 86/54 276 16622 79/47 240 13811 74/42 184 9839 65/33 09AL 91 4MDE 448 39142 95/63 380 30100 89/57 364 28050 88/56 306 21542 81/49 262 17233 76/44 204 12283 67/35 09AL 91 6MDC 2 x 3 - ø900 546 44917 95/63 462 34558 89/57 428 30800 88/56 356 23650 81/49 304 19250 76/44 238 13750 67/35 09AL 91 6MDD 2 x 3 - ø900 2 x 3 - ø900 652 47667 95/63 550 36667 89/57 506 32450 88/56 414 24933 81/49 360 20717 76/44 276 14758 67/35 09AL 91 6MDE 598 52189 96/64 506 40133 90/58 484 37400 89/57 408 28722 82/50 350 22978 77/45 272 16378 68/36 09AL 91 8MDC 2 x 4 - ø900 728 59889 96/63 616 46078 90/58 570 41067 89/56 474 31533 82/49 404 25667 77/44 295 18333 68/35 09AL 91 8MDD 2 x 4 - ø900 2 x 4 - ø900 868 63556 96/63 732 48889 90/57 674 43267 89/56 552 33244 82/49 480 27622 77/44 368 19678 68/35 09AL 91 8MDE 746 65236 97/64 632 50167 91/58 606 46750 90/57 510 35903 83/50 436 28722 78/45 340 20472 69/36 09AL 91 10MDC 2 x 5 - ø900 910 74861 97/64 770 57597 91/58 712 51333 90/57 592 39417 83/50 506 32083 78/45 396 22917 69/36 09AL 91 10MDD 2 x 5 - ø900 1086 79444 97/64 916 61111 91/58 842 54083 90/57 688 41556 83/50 600 34528 78/45 460 24597 69/36 09AL 91 10MDE 2 x 5 - ø900 896 78283 98/65 758 60200 92/59 726 56100 91/58 612 43083 84/51 524 34467 79/46 406 24567 70/37 09AL 91 12MDC 2 x 6 - ø900 1092 89833 98/65 924 69117 92/59 854 61600 91/58 710 47300 84/51 606 38500 79/46 474 27500 70/37 09AL 91 12MDD 2 x 6 - ø900 CAP - Nominal capacity AF - Air flow LwA - Sound power level LpA - Sound pressure level at 10 m Note: Performance data given for units with AC-motor fans, 400-3-50 power supply, refrigerant R-404A, Δt1 =15 K, operating pressure 26 bar, ENV327. For performance data for units with other refrigerants or fans and for 09FCAL 91 dry coolers, see technical documentation or electronic selection program. Fan data Correction factors for different refrigerants Asynchronous Motors Diameter Number of poles 6P 8P 900 mm 12P Speed* Wiring H H L H L Power input (kW) 2.2 1.3 0.8 0.5 0.25 Δ Δ Y Δ Y Temperature difference ΔT, K Refrigerant 8 10 12 0.67 0.80 R-404A – R-22 – R-134a – R-507 0.53 0.46 0.62 0.77 R-407C, R-407A Full load current (A) 5.3 3.5 1.7 1.5 0.65 * H: High, L: Low Number of poles Speed (rpm) 910 mm NA 910 mm NA 1000 910 750 690 560 610 560 470 330 200 Wiring NA NA Power input (kW) 3.12 2.26 1.28 1.01 0.56 0.6 0.45 0.26 0.1 0.04 Full load current (A) 4.9 3.5 2 1.7 1.1 1.2 0.9 0.6 0.3 0.2 Models 09AL 91 3MSC 09AL 91 3MSD 09AL 91 3MSE 09AL 91 4MSC 09AL 91 4MSD 09AL 91 4MSE 09AL 91 5MSC 09AL 91 5MSD 09AL 91 5MSE 09AL 91 6MSC 09AL 91 6MSD 09AL 91 4MDC 09AL 91 4MDD 09AL 91 4MDE 09AL 91 6MDC 09AL 91 6MDD 09AL 91 6MDE 09AL 91 8MDC 09AL 91 8MDD 09AL 91 8MDE 09AL 91 10MDC 09AL 91 10MDD 09AL 91 10MDE 09AL 91 12MDC 09AL 91 12MDD G 200 F 779 588 688 1430 A 200 1118 C Single-row models Dimensions, mm A C 4921 4567 6046 5692 7171 6817 6422 6068 7922 7568 9422 9068 7924 7570 9799 9444 11674 11320 9426 9072 11676 11322 3420 3066 4170 3816 4920 4566 4921 4567 6046 6692 7171 6817 6422 6068 7922 7568 9422 9068 7924 7570 9799 9445 11674 11320 9426 9072 11676 11322 20 1.33 1.38 Net weight, kg F 2285 3036 3786 4536 3036 3787 4536 3037 3787 2285 3036 3789 4536 3036 3787 4536 3037 3787 Note: Dimension A is the maximum length. G F C 779 588 688 1430 A 200 17 1.13 1.15 Dimensions and weights EC-Motors Diameter 15 1.00 1.00 200 2182 Double-row models 71 G 1502 1876 2252 3003 3753 1502 1876 2252 3003 3753 566 680 765 755 886 1001 945 1109 1250 1115 1314 695 807 903 1014 1195 1341 1351 1569 1762 1683 1958 2207 2007 2333 Heating Index System architecture 72 Index Type Range Air-to-water heat pumps, axial fan With scroll or rotary compressors 38AW/80AW 30AWH 80HMA 61AF 014-019 61AF 022-105 30RQ 017-033 30RQY 017-033 30RQS 039-160 30RQSY 039-160 30RQ 182-522 Water-to-water heat pumps With scroll compressors 61WG With screw compressors 30XWH 30XWHV Refrigerant Cooling capacity, kW R-410A R-410A 4.2-9 5-11.5 3-13 4-14 4-20 kW, depending on the heat pump used 14-20 21-102 16-33 17-33 15-32 17-31 38-149 42-158 37-147 42-159 175-470 181-554 74 76 78 80 82 84 86 88 90 92 273-1732 94 96 98 R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-134a R-134a Heating capacity, kW 29-117 317-1969 648-1932 Page Application of the new EN14511 : 2013 chiller and heat pump performance standard: Chiller and heat pump performances are calculated in accordance with the EN14511 : 2013 calculation standard and certified by Eurovent. The latest version of EN14511. It uses a different method to take into account the contribution of water pumps, or heat exchanger pressure drops in the unit performances. The efficiency of the pump is no longer a default value, but a function of the required hydraulic power. In January 2012, the Eurovent Certification Company decided that this method is more realistic and it is fully applied starting from the 2012 certification campaign. The performances declared based on the new version of the standard were published on the ECC website www.eurovent-certification.com at the end of March 2012. IMPORTANT: Only 2012 performances rated according the new EN14511 : 2013, taking in account water pump and heat exchanger pressure drop are certified by Eurovent. For units declared before 2012, the previous gross EER and COP values without pump correction (for units with integral pump - measured with the pump not running) and the corresponding energy classes are available on ECC website. Application rating conditions Air conditioning applications (AC) Air-cooled cooling - condition 1 Evaporator EWT/LWT 12°C/7°C OAT 35°C Air-cooled heating - condition 1 Condenser EWT/LWT 40°C/45°C EWT/LWT 40°C/45°C Evaporator OAT 7°C OAT 2°C Water-cooled cooling - condition 1 Evaporator EWT/LWT 12°C/7°C Condenser EWT/LWT 30°C/35°C Water-cooled heating - condition 1 Condenser EWT/LWT 10°C/7°C Condenser EWT/LWT 40°C/45°C Cooling and heating floor applications (CHF) Condition 2 Evaporator EWT/LWT 23°C/18°C OAT 35°C Condition 2 Condenser EWT/LWT 30°C/35°C EWT/LWT 30°C/35°C Evaporator OAT 7°C OAT 2°C Condition 2 Evaporator EWT/LWT 23°C/18°C Condenser EWT/LWT 30°C/35°C Condition 2 Evaporator EWT/LWT 10°C/7°C Condenser EWT/LWT 30°C/35°C High-temperature heating (HT) Very high-temperature heating (VHT) Condenser EWT/LWT 47°C/55°C EWT/LWT 47°C/55°C Condenser EWT/LWT 50°C/65°C EWT/LWT 47°C/55°C Evaporator OAT 7°C OAT 2°C Evaporator OAT 7°C OAT 2°C Evaporator EWT/LWT 10°C/7°C Condenser EWT/LWT 47°C/55°C Legend EWT Entering water temperature LWT Leaving water temperature OAT Outdoor air temperature 73 Evaporator EWT/LWT 0°C/-3°C Condenser EWT/LWT 47°C/55°C AIR-TO-WATER HEAT PUMP HEATING SYSTEM Heating 38AW/ 80AW Accessories Features t "EEJUJPOBMVTFSJOUFSGBDF t $PNNVOJDBUJPOLJU t 3FNPUFPVUEPPSBJSTFOTPSNBYJNJTFT comfort. t 3PPNUFNQFSBUVSFTFOTPS t %PNFTUJDIPUXBUFSUBOLPOFPS two coils - storage, 200 l/300 l of domestic hot water with or without thermal solar panel connection. t $%6SVCCFSWJCSBUJPOJTPMBUPST t %PNFTUJDIPUXBUFSUISFFXBZWBMWF and actuator. t 5IFSNBMDVUPVUnPPSIFBUJOHUP connect under-floor heating zone. t 5XP[POFLJUBMMPXTJOEFQFOEFOU control of two comfort zones t 1JQJOHLJUUPJOTUBMMEPNFTUJDIPU water valve and actuator inside unit. t $PWFSQBOFMUPJOTUBMMUXP[POFLJU detached from comfort module. t &JHIUTJ[FTXJUIOPNJOBMIFBUJOHDBQBDJUJFTGSPNUPL8BOEOPNJOBM cooling capacities from 4.2 to 9.0 kW. t 3FWFSTJCMF91&OFSHZBJSUPXBUFSTQMJUTZTUFNIFBUQVNQTXJUICVJMUJOJOWFSUFS technology, designed for residential and light commercial applications, offer excellent energy efficiency values, exceptionally quiet operation and meet the most stringent operating temperature demands. t *ODPSQPSBUFUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOTP[POFGSJFOEMZSFGSJHFSBOU R-410A, DC inverter twin-rotary compressors, low-noise fan and microprocessor control. t %FTJHOFEGPSFBTFPGJOTUBMMBUJPOBOETFSWJDF t 'PSBEEFEnFYJCJMJUZUIF91&OFSHZTZTUFNTBSFBWBJMBCMFJOIFBUJOHPOMZPS reversible versions, to suit the demand. Back-up heating with either electrical (single-energy applications) or gas boiler (dual-energy applications). t $BOCFVTFEXJUIBXJEFDIPJDFPG$BSSJFSUFSNJOBMGBODPJMVOJUTDBTTFUUFT low, medium and high-pressure satellite units, console units, under-ceiling units and high-wall units. t 8JEFPQFSBUJOHSBOHFJOCPUIIFBUJOHBOEDPPMJOHNPEFPòFSJOHIJHI performance in a wide temperature range. t %$JOWFSUFSUXJOSPUBSZDPNQSFTTPSTHVBSBOUFFFOIBODFESFMJBCJMJUZMPXFOFSHZ consumption and smooth operation under all operating conditions. t 7BSJBCMFTQFFEGBOTXJUIBOJOOPWBUJWFQBUFOUFEGBOCMBEFTIBQFFOTVSF improved air distribution at exceptionally low noise levels. t 1SFTFUPSDVTUPNJTFETFMFDUJPOPGUIFBQQSPQSJBUFDMJNBUFDVSWFGPSTUBCMF output capacity to match the heat load. t 0VUQVUUPMJOLBOEJOUFHSBUFUIFVOJUXJUIFYJTUJOHIFBUTPVSDFTGPSEVBM energy approach with increased savings and optimum comfort in all conditions. t "CMFUPDPOUSPMUXPJOEFQFOEFOUDPNGPSU[POFTXJUIBUXP[POFLJUBEEFEUP the main comfort module. t -FBWJOHXBUFSUFNQFSBUVSFVQUP¡$GPSSBEJBUPSBOEEPNFTUJDIPUXBUFS applications, making hot water readily available. Control t 6TFSGSJFOEMZDPOUSPMMFSXJUIMBSHF display, intuitive symbols and two simple buttons, allowing the user to select the desired operating parameter values. 74 38AW/ 80AW Physical data, indoor and outdoor units System Outdoor unit (heat pump) Indoor unit (comfort module) Max. leaving water temperature Nominal heating capacity* Min./Max. heating capacity* COP* Nominal cooling capacity** Min./Max. heating capacity** EER** * ** °C kW kW kW/kW kW kW kW/kW Heating only 38AW 050H7 80AWH 065 60 5.0 1.5/6.3 4.10 - 38AW 065H7 80AWH 065 60 6.5 1.4/8 4.10 38AW 115H7 80AWH 115 60 11.5 4.6/13.4 4.10 - 38AW 120H9 80AWH 150 60 12 6.0/15.0 4.65 - 38AW 150H9 80AWH 150 60 15.1 6.0/16.0 4.3 - Heating and cooling 38AW 38AW 050H7 065H7 80AWX 80AWX 065 065 60 60 5 6.5 1.5/6.3 1.4/8 4.1 4.1 5.1 6.5 0.7/5.7 0.8/7.1 3.4 3.4 38AW 090H7 80AWX 115 60 9.1 4.6/11.7 4.2 7.9 4.1/9.2 4.05 38AW 115H7 80AWX 115 60 11.5 4.6/13.4 4.1 9 4.1/12.1 3.8 38AW 120H9 80AWH 150 60 12 6.0/15.0 4.65 13.5 7.1/17.9 4.74 38AW 150H9 80AWH 150 60 15.1 6.0/16.0 4.3 15.79 7.1/17.7 4.24 The nominal heating capacity is in accordance with EN 14511, water temperature 35°C/30°C, air temperature 7°C/6°C The nominal cooling capacity is in accordance with EN 14511, water temperature 18°C/23°C, air temperature 35°C Outdoor unit (heat pump) 38AW 050H7 80AW 065 1 38AW 065H7 80AW 065 1 38AW 090H7 80AW 115 1 38AW 115H7 80AW 115 1 38AW 120H9 80AWH 150 1 38AW 150H9 80AWH 150 1 0.24 (860) 0.19 (688) 0.29 (1032) 5 40.9 40.9 800 x 450 x 320 48 38AW 050H7 DC twin-rotary 0.31 (1118) 0.25 (894) 0.37 (1342) 5 40.9 40.9 800 x 450 x 320 48 38AW 065H7 DC twin-rotary 0.43 (1548) 0.34 (1238) 0.52 (1858) 5 40.9 40.9 800 x 450 x 320 50 38AW 090H7 DC twin-rotary 0.55 (1978) 0.44 (1582) 0.66 (2374) 5 40.9 40.9 800 x 450 x 320 50 38AW 115H7 DC twin-rotary 0.57 (2065) 0.29 (1030) 0.72 (2580) 5 40.9 40.9 800 x 450 x 320 52 38AW 120H9 DC twin-rotary 0.72 (2580) 0.29 (1030) 0.76 (2750) 5 40.9 40.9 800 x 450 x 320 52 38AW 150H9 DC twin-rotary PAM + PWM PAM + PWM PAM + PWM PAM + PWM PAM + PWM PAM + PWM R-410A R-410A R-410A R-410A R-410A R-410A m 50 30 70 70 70 70 m 30 30 30 30 30 30 Indoor unit (comfort module) Number of comfort zones Nominal water flow rate Minimum water flow rate Maximum water flow rate Nominal temperature difference Sound power level, cooling Sound power level, heating Dimensions, H x L x D Operating weight Outdoor unit Compressor type Inverter type Refrigerant Maximum pipe length Maximum height difference Pre-charged length Air flow Dimensions, H x L x D Operating weight Pipe connections Power supply *** 38AW 090H7 80AWH 115 60 9.1 4.6/11.7 4.20 - l/s (l/h) l/s (l/h) l/s (l/h) K dB(A) dB(A) mm kg m 20 20 20 30 30 30 l/s (m3/h) 728 (2620) 783 (2820) 1658 (5970) 1767 (6360) 1600 (5770) 1600 (5770) mm 690 x 900 x 320 820 x 900 x 320 1360 x 900 x 320 1360 x 900 x 320 1360 x 900 x 320 1360 x 900 x 320 kg 49 51 88 88 100 100 in 1/4 - 1/2 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 400-3-50 400-3-50 Sound pressure levels are given for a distance of 4 m from the unit. Indoor unit for 38AW 120H9 and 38AW 150H9 Number of comfort zones Electric heater element Heating only Heating and cooling Connection of back-up boiler Power supply kW V-ph-Hz 80AWX 150M0 1 0 No Yes Yes 230-1-50 80AWX 150T6 1 9 No Yes No 400-3-50 80AWX 150T9 1 9 No Yes No 400-3-50 80AWH 150MO 1 0 Yes No Yes 230-1-50 80AWH 150T6 1 6 Yes No No 400-3-50 80AWH 150T9 1 9 Yes No Yes 400-3-50 38AW 065 230-1-50/198-264 11.7/9.0 16 1930 2.5 0.95 38AW 090 230-1-50/198-264 18.9/13.4 25 2887 2.5 0.95 38AW 115 230-1-50/198-264 21.2/17.9 25 3731 2.5 0.95 38AW 120 400-3-50/376-424 15.4/16 6.45 2580 2.5 0.95 38AW 150 400-3-50/376-424 15.4/16 8.72 3490 2.5 0.95 Electrical data, indoor and outdoor units Outdoor unit Power supply/voltage range Full load current/operating current Fuse rating* Power consumption Main power wire size Power factor * Time delay fuse V-ph-Hz/V A A W mm2 % Comfort module 80AW 065 M0 M3 M6 38AW 050H7/38AW 065H7 Outdoor units Power supply Power input Operating current 38AW 050 230-1-50/198-264 11/7.9 16 1473 2.5 0.95 V-ph-Hz kW A 230-1-50 ± 10% 3 13 6 26 T6 400-3-50 ± 10% 6 L1: 13 L2: 13 N: 13 75 80AW 115 M0 M3 M6 38AW 090H7/38AW 115H7 230-1-50 ± 10% 3 13 6 26 T6 T9 400-3-50 ± 10% 6 9 L1: 13 L1: 19.5 L2: 13 L2: 19.5 N: 13 N: 19.5 REVERSIBLE AIR-TO-WATER HEAT PUMPS Heating Reversible 30AWH Options/accessories Features t 6OJUXJUIPVUIZESPOJDNPEVMF (option) t 6OJUXJUIIZESPOJDNPEVMFPQUJPO t 6OJUXJUIWBSJBCMFTQFFEQVNQ (option)* t "EEJUJPOBMPVUEPPSTFOTPSBDDFTTPSZ t 3FNPUFDPOUSPMMFS"83$ (accessory) t 1SPHSBNNBCMFUIFSNPTUBU 33AW-CS1 (accessory) t 5XPWFSTJPOTXJUIPSXJUIPVUIZESPOJDNPEVMFJOmWFTJ[FTXJUIOPNJOBMDPPMJOH capacities from 3 to 13 kW and nominal heating capacities from 4 to 14 kW. t "RVB4OBQ1-64BJSUPXBUFSIFBUQVNQTXJUICVJMUJOJOWFSUFSUFDIOPMPHZ were designed for residential and light commercial applications. They offer excellent energy efficiency values, exceptionally quiet operation and meet the most stringent operating temperature demands. t 6OJUTJOUFHSBUFUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOTP[POFGSJFOEMZSFGSJHFSBOU R-410A, DC inverter twin-rotary compressors, low-noise fan and microprocessor control. t 4QFDJmDBMMZEFTJHOFEGPSFBTFPGJOTUBMMBUJPOBOETFSWJDFBOEVOEFSMJOJOH Carrier’s reputation for highest product quality and reliability. t "RVB4OBQ1-64IFBUQVNQTZTUFNTDBOCFVTFEXJUIBXJEFDIPJDFPG$BSSJFS terminal fan coil units - cassettes, low, medium and high-pressure satellite units, console units, underceiling units and high-wall units. t 8JEFPQFSBUJOHSBOHFJOCPUIIFBUJOHBOEDPPMJOHNPEFPòFSJOHIJHI performance in a wide temperature range. t %$JOWFSUFSUXJOSPUBSZDPNQSFTTPSTXJUI1VMTF"NQMJUVEF.PEVMBUJPO1". and Pulse Width Modulation (PWM) for enhanced reliability, low energy consumption and smooth vibration-free operation under all operating conditions. t 7BSJBCMFTQFFEGBOTXJUIBOJOOPWBUJWFQBUFOUFEGBOCMBEFTIBQFFOTVSF improved air distribution at exceptionally low noise levels. t 0VUQVUUPMJOLBOEJOUFHSBUFUIFVOJUXJUIFYJTUJOHIFBUTPVSDFTUPPòFSB bivalent approach, increased savings and optimum comfort in all weather conditions. t -FBWJOHXBUFSUFNQFSBUVSFVQUP¡$GPSEPNFTUJDIPUXBUFSBQQMJDBUJPOT making hot water readily available. t "EWBODFEDJSDVJUEFTJHOBOEDPNQPOFOUTFMFDUJPOIBTSFTVMUFEJOBDPNQBDU unit with an exceptionally small footprint that can be easily transported even through narrow doors. t $PNQSFIFOTJWFRVBMJUZBOEFOEVSBODFUFTUT t &OIBODFEDPOUSPMQPTTJCJMJUJFT * Available in 2013 30AW controllers ComfortTM Series programmable thermostat 33AW-CS1 Remote controller 33AW-RC1 Technology 76 30AWH 004-015 Physical data 30AW Air conditioning application as per EN14511-3 : 2013 kW Nominal cooling capacity kW Nominal heating capacity EER (cooling)/COP (heating) kW/kW ESEER part-load performance, cooling kW/kW Cooling/heating floor application as per EN14511-3 : 2013 kW Nominal cooling capacity kW Nominal heating capacity EER (cooling)/COP (heating) kW/kW Operating weight, unit with/without hydronic module* kg Refrigerant Compressor Fans Quantity/diameter mm Dimensions Length x depth x height mm 004 006 008 012 015 012-3Ph 015-3Ph 3.3 4.0 3.02/3.26 4.36 4.7 6.0 3.00/3.05 4.51 5.8 7.0 2.98/3.19 4.15 10.2 13.0 2.96/3.03 4.22 13.0 14.0 2.95/3.23 4.31 10.2 13.0 3/3.35 4.4 13 14.0 2.91/3.3 4.31 4.93 7.04 7.84 4.0 6.0 7.0 4.2/4.2 3.7/4.3 3.99/4..0 57/54 61/58 69/66 R-410 R-410A R-410A DC twin-rotary with PMV expansion valve Propeller fans 1/495 1/495 1/495 13.54 12.0 3.66/4.0 104/101 R-410A 16.04 14.0 3.85/4.1 112/109 R-410A 13.5 13 4.15/4.3 116/113 R-410A 16 14 3.81/4.2 116/113 R-410A 2/495 2/495 2/495 2/495 908 x 350 x 821 908 x 350 x 1363 908 x 350 x 1363 908 x 350 x 1363 908 x 350 x 1363 908 x 350 x 821 908 x 350 x 821 NOTE: For the conditions please refer to page 73. * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30AW Power supply Voltage range Full load current Fuse rating Main power cable section V-ph-Hz V A A mm2 004 230-1-50 198-264 7.2 10 2.5 006 230-1-50 198-264 11 16 2.5 008 230-1-50 198-264 14 16 2.5 012 230-1-50 198-264 23 25 2.5 015 230-1-50 198-264 20 25 2.5 012-3Ph 400-3-50 376-424 16 20 2.5 015-3Ph 400-3-50 376-424 16 20 2.5 Operating range Cooling mode Heating mode 20 70 30AWH 006 Leaving water temperature, °C Leaving water temperature, °C 18 16 30AWH 004 14 12 10 8 6 4 60 50 40 30 20 10 2 -25 -20 -15 -10 -5 0 5 10 15 Outside air temperature, °C 0 -5 0 5 10 15 20 25 30 35 40 45 50 Outside air temperature, °C 77 20 25 30 35 COMFORT MODULE RANGE FOR MONOBLOC HEAT PUMPS Heating 80HMA Accessories Features t $PNNVOJDBUJPOLJUGPSJOTUBMMBUJPO on the heat pump t "EEJUJPOBMVTFSJOUFSGBDFNPOJUPST two independent comfort zones or used together with comfort module interface t 3FNPUFPVUEPPSTFOTPSNBYJNJTFT comfort compared to using the condensing unit OAT sensor t %PNFTUJDIPUXBUFSUBOLGPSTUPSBHF of domestic hot water, one or two coils, 200 or 300 litres, with or without thermal solar panel connection t %PNFTUJDIPUXBUFSUISFFXBZWBMWF and actuator to connect domestic hot water tank t 5IFSNBMDVUPVUnPPSIFBUJOH stops circulation pump when supply temperature is too high t 1JQJOHLJUUPJOTUBMMEPNFTUJDIPU water valve and actuator inside the unit. t $PWFSQBOFMUPJOTUBMMUXP[POFLJU detached from comfort module. t ,JUUPBEEUISFFXBZWBMWFBOE actuator in second zone t 5XP[POFLJUBMMPXTJOEFQFOEFOU control of two comfort zones t 4XJNNJOHQPPMLJUDPOUSPMTTXJNNJOH pool heating, using the heat pump t 1VNQLJUOFDFTTBSZXIFOBWBJMBCMF heat pump pressure is too low for the installation t #1)&LJUGPSIFBUQVNQTVQUPPS 16 kW - separate heat pump loop (with glycol) from indoor loop; includes BPHE and pump t 'JWFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOEOPNJOBM heating capacities from 4 to 20 kW, depending on the heat pump model used. t 5IFOFXDPNGPSUNPEVMFSBOHFGPSNPOPCMPDJOWFSUFSIFBUQVNQTPòFSTB complete heating system that is easy to design and install. t 4ZTUFNDPOUSPMTFOTVSFPQUJNJTFEFOFSHZFóDJFODZVTJOHBVUPBEBQUBUJWF weather compensation control that constantly monitors the indoor and outdoor climate to optimise the heat pump energy efficiency and deliver perfect indoor climate. t 8JUIJUTJNQSPWFEBFTUIFUJDTBOEDPNQBDUOFTTDPNCJOFEXJUIOFXGFBUVSFT and options, the new comfort module sets new standards in energy savings and comfort. Using the two-zone kit, two different terminal unit types or two independent comfort zones can be closely monitored. Domestic hot water production is made easy and can be interfaced with thermal solar panels. t "MM"8))$TJ[FTBSFDPNQBUJCMFXJUIUIF)."DPNGPSUNPEVMFSBOHF The comfort module controls can also manage up to eight 30AWH units. 30RQ 017 to 021 and 61AF 014 to 019 units are also compatible, but the water volume of this installation needs to be checked. t 3FWFSTJCMFPQFSBUJPO t &MFDUSJDCPPTUFSIFBUFSPSCPJMFSCBDLVQ t "VUPBEBQUBUJWFXFBUIFSDPNQFOTBUJPODPOUSPM t %VBMDPNGPSU[POFXJUIJOEFQFOEFOUDPOUSPMPGUXPUFSNJOBMVOJUUZQFT t 6TFSGSJFOEMZDPOUSPMMFSXJUIMBSHFEJTQMBZJOUVJUJWFTZNCPMTBOEUXPTJNQMF buttons, allowing the user to select the desired operating parameter values. Operator interface 78 80HMA Physical data Indoor unit (comfort module) Number of comfort zones Electric booster element Number of auxiliary heating steps Connection of back-up boiler Dimensions, H x L x D Operating weight Power supply Recommended circuit breaker size kW mm kg V-ph-Hz 80HMA-M00 1 0 1 (external boiler) Yes 800 x 450 x 320 34 230-1-50 C6 80HMA-M03 1 3 1 No 800 x 450 x 320 35 230-1-50 C20 80HMA-M06 1 6 3 No 800 x 450 x 320 35 230-1-50 C32 80HMA-T06 1 6 3 No 800 x 450 x 320 35 400-3-50 C16 80HMA-T09 1 9 3 No 800 x 450 x 320 35 400-3-50 C20 Combination table, indoor and outdoor units Outdoor unit (heat pump) 30AWH04HC 30AWH06HC 30AWH08HC 30AWH12HC 30AWH12HC9 30AWH15HC 30AWH15HC9 Nominal capacity 4 kW Nominal capacity 6 kW Nominal capacity 8 kW Nominal capacity 12 kW Nominal capacity 12 kW Nominal capacity 15 kW Nominal capacity 15 kW Indoor unit (comfort module) 80HMA-M00 80HMA-M03 80HMA-M06 80HMA-T06 80HMA-T06 80HMA-T09 80HMA-T09 Reversible, 1 zone, maximum heating capacity 20 kW for boiler back-up application Reversible, 1 zone, maximum heating capacity 20 kW with 3 kW 1-phase electrical heater booster Reversible, 1 zone, maximum heating capacity 20 kW with 6 kW 1-phase electrical heater booster Reversible, 1 zone, maximum heating capacity 20 kW with 6 kW 3-phase electrical heater booster Reversible, 1 zone, maximum heating capacity 20 kW with 6 kW 3-phase electrical heater booster Reversible, 1 zone, maximum heating capacity 20 kW with 9 kW 3-phase electrical heater booster Reversible, 1 zone, maximum heating capacity 20 kW with 9 kW 3-phase electrical heater booster NOTE: All 30AWH sizes are compatible with the 80HMA comfort module range. Comfort module controls can also manage up to eight 30AWH units. A parallel hydronic coupling of the unit to a tank is necessary (field supply). 30RQ 017 to 021 and 61AF 014 to 019 units are also compatible, but the water volume of this installation must be checked by a professional and comply with the heat pump size minimum requirements. Depending on the terminal unit type installed with the Carrier system a buffer tank may have to be added. Electrical data Comfort module 80HMA Power supply Voltage range Max. power consumption, board and auxiliary devices Board and auxiliary circuit breaker protection (not included) Electric heater power consumption Electric heater circuit breaker protection (not included) Max. operating current Main power cable size Communication cable (FROH2R) User interface (additional or remote) cable (FROH2R) Booster heater power supply cable (H05VV-F) Booster heater activation cable (FROH2R) Domstic hot water sensor cable (FROH2R) Remote outdoor sensor cable (FROH2R) V-ph-Hz V kW kW A mm2 mm2 mm2 mm2 mm2 mm2 mm2 M00 230-1-50 207-253 1.15 C6 0 C6 5 3G x 2.5 2 x 0.75 4 x 0.75 3G x 2.5 2x1 2 x 0.5 2 x 0.5 M03 230-1-50 207-253 1.15 C6 3 C20 18 3G x 4 2 x 0.75 4 x 0.75 3G x 2.5 2x1 2 x 0.5 2 x 0.5 M06 230-1-50 207-253 1.15 C6 6 C32 31 3G x 6 2 x 0.75 4 x 0.75 3G x 2.5 2x1 2 x 0.5 2 x 0.5 Note: The heat pump data depends on the heat pump used. Operating limits Heat pump limits Comfort module limits Indoor temperature Water temperature, cooling Water temperature, heating Depends on the heat pump selected 5-30°C 4-18°C 20-80°C 79 T06 400-3-50 360-400 1.15 C6 6 C16 14 5G x 2.5 2 x 0.75 4 x 0.75 3G x 2.5 2x1 2 x 0.5 2 x 0.5 T09 400-3-50 360-400 1.15 C6 9 C20 18 5G x 4 2 x 0.75 4 x 0.75 3G x 2.5 2x1 2 x 0.5 2 x 0.5 HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMPS Heating Heating 61AF Accessories Features t t t t t t 5XPTJ[FTXJUIOPNJOBMIFBUJOHDBQBDJUJFTGSPNUPL8 t 5IF"RVBTOBQIJHIUFNQFSBUVSFIFBUQVNQSBOHFXBTEFTJHOFEGPSDPNNFSDJBM applications such as the heating of offices, apartments and hotels as well as domestic hot water production in new and refurbished buildings. t 6OJUTJODPSQPSBUFUIFMBUFTUUFDIOPMPHJDBMGFBUVSFTTDSPMMDPNQSFTTPSTXJUI vapour injection, low-noise fans made of a composite material, auto-adaptative microprocessor control, electronic expansion valve and multi-speed pump. t 6OJUTDFSUJmFEUPUIF&VSPWFOUFOFSHZFóDJFODZDMBTT"XJUIB$01PGPWFS and comply with the COP required by the Ecolabel certification. t "'IFBUQVNQTJODPSQPSBUFBIZESPOJDNPEVMFXJUIBNVMUJTQFFEQVNQ as standard. t -PXOPJTFMFWFMTBOEBWFSZDPNQBDUDIBTTJTSFEVDFUIFOPJTFEJTUVSCBODF from the unit. t 5IFPQFSBUJOHSBOHFBMMPXTPVUTJEFUFNQFSBUVSFTEPXOUP¡$BOEMFBWJOH water temperatures up to 65°C for domestic hot water applications. t *OUFMMJHFOUVOJUDPOUSPMQFSNJUTVOJUPQFSBUJPOJOFYUSFNFDPOEJUJPOT minimising unit shut-down times. t 4ZTUFNBUJDGBDUPSZSVOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPS verification of instruments, electrical components and motors. t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t $PNQSFIFOTJWFRVBMJUZBOEFOEVSBODFUFTUT +#VT#BD/FUBOE-PO5BMLHBUFXBZT 3FNPUFVTFSJOUFSGBDF .BTUFSTMBWFPQFSBUJPO )ZESPOJDNPEVMF 8BUFSmMUFS \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 80 61AF 014-019 Physical data 61AF Air conditioning application as per EN14511-3 : 2013 Condition 1 Nominal heating capacity COP Eurovent class, heating Condition 2 Nominal heating capacity COP Operating weight* Standard unit without hydronic module Standard unit with hydronic module option Compressor Refrigerant* Condenser Fan Quantity Air flow Evaporator Dimensions Length x depth x height NOTE: For the conditions please refer to page 73. * 014-7 014-9 019 kW kW/kW 14.1 3.32 A 13.7 3.50 A 19.8 3.45 A kW kW/kW 13.9 3.89 13.5 4.16 20.2 4.24 kg kg 159 169 One, hermetic scroll, 48.3 r/s R-407C Direct-expansion plate heat exchanger Axial 2 2050 Grooved copper tubes and aluminium fins 159 169 206 216 2 2050 2 2000 1103 x 333 x 1278 1135 x 559 x 1579 l/s mm 1103 x 333 x 1278 Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 61AF - Standard unit Without pump 014-7 014-9 25 45 019 With pump 014-7 014-9 019 Power circuit Nominal power supply V-ph-Hz 230-1-50 ± 10% 400-3-50 ± 10% 400-3-50 ± 10% 230-1-50 ± 10% 400-3-50 ± 10% 400-3-50 ± 10% 24 V, via internal transformer Control circuit supply Maximum start-up current (Un)* 66 102 67 104 Standard unit A 47 48 Unit with electronic starter option A 0.82 0.82 0.82 0.82 0.82 0.82 Unit power factor at maximum capacity** kW 6.41 5.90 8.80 6.41 6.10 9.20 Maximum unit power input** A 22.9 7.9 12.4 23.7 7.9 12.4 Nominal unit current draw*** A 30.7 10.8 16.0 31.5 10.8 16.0 Maximum unit current draw (Un)**** * Maximum instantaneous start-up current at operating limit values (maximum operating current of the pump + fan current + locked rotor current of the compressor). ** Power input, compressors and fan, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: condenser entering/leaving water temperature 40°C/45°C, outside air temperature 7°C. **** Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Operating range 70 65 Leaving water temperature, °C 60 55 50 45 40 35 30 25 20 -25 -20 -15 -10 -5 0 5 10 15 20 30 35 40 Entering air temperature, °C Full load 81 HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMPS Heating Heating 61AF Options/accessories Features t "OUJDPSSPTJPOQSPUFDUJPO traditional coils (option) t 6OJUTXJUIEJTDIBSHFBJSEVDUT (option) t -PXBOEWFSZMPXOPJTFMFWFM (option) t 4PGUTUBSUFSPQUJPO t 'SPTUQSPUFDUJPOEPXOUP¡$ (option) t -PXQSFTTVSFTJOHMFQVNQIZESPOJD module (option) t +#VT#BD/FUBOE-PO5BMLHBUFXBZT (option) t 4DSFXPSXFMEFEXBUFSDPOOFDUJPO between the customer’s condenser and the unit (option) t 3FNPUFVTFSJOUFSGBDFPQUJPO t .BTUFSTMBWFPQFSBUJPOPQUJPO t )FBUJOH4ZTUFN.BOBHFSUZQFT"# and C: control of comfort heating (one or more zones) and domestic hot water production in installations where the 61AF is backed up by auxiliary boilers, electric resistance heaters or a district heating system (accessory) t 4FWFOTJ[FTXJUIOPNJOBMIFBUJOHDBQBDJUJFTGSPNUPL8 t 5IF"RVBTOBQIJHIUFNQFSBUVSFIFBUQVNQSBOHFXBTEFTJHOFEGPSDPNNFSDJBM applications such as the heating of offices, apartments and hotels as well as domestic hot water production in new and refurbished buildings. t 6OJUTJODPSQPSBUFUIFMBUFTUUFDIOPMPHJDBMGFBUVSFTTDSPMMDPNQSFTTPSTXJUI vapour injection, low-noise fans made of a composite material, auto-adaptative microprocessor control, electronic expansion valve and multi-speed pump. t *ODSFBTFEFOFSHZFóDJFODZ&VSPWFOUFOFSHZFóDJFODZDMBTT"JOBDDPSEBODF with EN14511-3:2013). t &YDFQUJPOBMFOFSHZFóDJFODZMFWFM$01 UIFSFTVMUPGBMPOHRVBMJmDBUJPO and optimisation process. t "'VOJUTJODPSQPSBUFBOPQUJPOBMIZESPOJDNPEVMFXJUIBNVMUJTQFFEQVNQ t -PXOPJTFMFWFMTBOEBWFSZDPNQBDUDIBTTJTSFEVDFUIFOPJTFEJTUVSCBODF from the unit. t 5IFPQFSBUJOHSBOHFBMMPXTPVUTJEFUFNQFSBUVSFTEPXOUP¡$BOEMFBWJOH water temperatures up to 65°C for domestic hot water applications. t *OUFMMJHFOUVOJUDPOUSPMQFSNJUTVOJUPQFSBUJPOJOFYUSFNFDPOEJUJPOT minimising unit shut-down times. t 4ZTUFNBUJDGBDUPSZSVOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPS verification of instruments, electrical components and motors. t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t $PNQSFIFOTJWFRVBMJUZBOEFOEVSBODFUFTUT \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 82 Hydronic module 61AF 022-105 Physical data 61AF Air conditioning application as per EN14511-3 : 2013 Condition 1 kW Nominal heating capacity kW/kW COP Eurovent class, heating Condition 2 kW Nominal heating capacity kW/kW COP Operating weight* Standard unit without hydronic module kg Standard unit with hydronic module option kg Compressor Condenser Fan Quantity Total air flow at high speed l/s Evaporator Refrigerant* Dimensions mm Length x depth x height 022 030 035 045 055 075 105 20.8 3.45 A 25.7 3.45 A 32.3 3.37 A 43.8 3.56 A 52.3 3.65 A 66.9 3.41 A 101.9 3.58 A 20.8 4.11 25.7 4.14 32.3 4.07 43.7 4.31 52.2 4.36 66.8 3.97 101.7 4.25 343 396 421 349 403 436 One, hermetic scroll 48.3 r/s Direct-expansion plate heat exchanger Axial with rotating shroud, Flying Bird IV 1 1 1 3770 3748 3736 Grooved copper tubes and aluminium fins R-407C 509 524 533 549 900 1020 926 1044 Two, hermetic scroll 48.3 r/s 1 4035 1 4036 2 7479 1110 x 1327 x 1330 1114 x 2100 x 1330 2 8072 2273 x 2100 x 1330 NOTE: For the conditions please refer to page 73. * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 61AF - Standard unit (without hydronic module) 022 030 035 045 055 075 105 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V, via internal transformer Control circuit supply Maximum start-up current (Un)* 104 102 130 170 190 157 229 Standard unit A 56 55 70 91 101 101 142 Unit with electronic starter option A 0.82 0.82 0.82 0.82 0.82 0.82 0.82 Unit power factor at maximum capacity** kW 8.7 11.6 12.9 14.6 16.8 25.8 33.7 Maximum unit power input** 13.6 16.4 20.1 23.2 27.7 40.2 55.4 A Nominal unit current draw*** 16.8 21.1 27.0 32.8 38.8 54.0 77.6 A Maximum unit current draw (Un)**** * Maximum instantaneous start-up current at operating limit values (maximum operating current of the compressor + fan current + locked rotor current of the compressor). ** Power input, compressors and fan, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: condenser entering/leaving water temperature 40°C/45°C, outside air temperature 7°C/6°C. **** Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Operating range 70 65 Leaving water temperature, °C 60 55 50 45 40 35 30 25 20 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 Entering air temperature, °C Full load 83 AIR-TO-WATER HEAT PUMPS Heating Reversible 30RQ Options/accessories Features t 6OJUXJUIPVUIZESPOJDNPEVMF (option) t *OUFHSBUFEXBUFSmMMTZTUFNPQUJPO t 1PXFSTVQQMZXJUIPVUOFVUSBMPQUJPO t +#VT#BD/FUBOE-PO5BMLHBUFXBZT (accessory) t 3FNPUFJOUFSGBDFBDDFTTPSZ t *OUFHSBUFEXBUFSmMMTZTUFN (accessory) t 'PVSTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOEOPNJOBM heating capacities from 17 to 33 kW. t "RVBTOBQIFBUQVNQTGPSDPNNFSDJBMBQQMJDBUJPOTTVDIBTUIFBJSDPOEJUJPOJOH of offices and hotels. t &YDFQUJPOBMMZIJHIFOFSHZFóDJFODZBUQBSUMPBE&VSPWFOUFOFSHZFóDJFODZ class A and B (in accordance with EN14511-3 : 2013) in cooling and heating mode. t *OUFHSBUFTUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOTP[POFGSJFOEMZSFGSJHFSBOU3" scroll compressors, low-noise fans and auto-adaptive microprocessor control. t 6OJUTJODMVEFBIZESPOJDNPEVMFJOUFHSBUFEJOUPUIFDIBTTJTMJNJUJOHJOTUBMMBUJPO to connection of power supply, water supply and return piping/air distribution ducting. t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 7FSUJDBMBJSIFBUFYDIBOHFSDPJMTXJUIQSPUFDUJPOHSJMMFTPOBOUJWJCSBUJPONPVOUJOHT t -PXOPJTFGBOTOPXFWFORVJFUFS3JHJEGBOJOTUBMMBUJPOGPSSFEVDFETUBSUVQOPJTF t 5IFVOJUIBTBTNBMMGPPUQSJOUBOEJTFODMPTFECZFBTJMZSFNPWBCMFQBOFMT t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 4ZTUFNBUJDPQFSBUJPOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPSTUFQ by-step verification of the instruments, electrical components and motors. t .BJOUFOBODFGSFFTDSPMMDPNQSFTTPSTBOEGBTUEJBHOPTJTPGQPTTJCMFJODJEFOUT and their history via the Pro-Dialog+ control reduce maintenance costs. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PSSPTJPOSFTJTUBODFUFTUTBDDFMFSBUFEBHFJOHUFTUPODPNQSFTTPSQJQJOHBOEGBO supports and transport simulation test on a vibrating table in the laboratory. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface Hydronic module (sizes 026-033 shown) 84 30RQ 017-033 Physical data 30RQ Air conditioning application as per EN14511-3 : 2013 Condition 1/condition 2 Nominal cooling capacity EER Eurovent class, cooling (condition 1) ESEER (condition 1) Heating application as per EN14511-3:2013 Condition 1/condition 2 Nominal heating capacity COP Eurovent class, heating (condition 1) Operating weight* Standard unit with/without hydronic module Refrigerant* Compressor Control Fans Air flow Water heat exchanger Air heat exchanger Unit with hydronic module Power input Nominal operating current Dimensions Length x depth x height 017 021 026 033 16.0/22.2 3.17/4.02 A 3.61 20.2/27.4 3.11/3.76 A 3.44 26.7/34.3 3.01/3.62 B 3.36 32.7/43.6 3.21/3.96 A 3.58 kW kW/kW 17.0/17.6 3.18/3.99 B 21.7/22.2 3.28/3.98 A 29.9/31.0 3.20/3.98 A 33.3/34.7 3.19/3.98 B kg kW A 206/191 223/208 280/262 295/277 R-410A One hermetic scroll compressor Pro-Dialog+ Two twin-speed axial fans, 3 blades One twin-speed axial fan, 7 blades 2217 1978 3530 3530 Plate heat exchanger Copper tubes and aluminium fins One single-speed pump, screen filter, expansion tank, flow switch, pressure gauge, automatic air purge valve, safety valve 0.54 0.59 0.99 1.10 1.30 1.40 2.40 2.60 mm 1136 x 584 x 1579 kW kW/kW kW/kW l/s 1136 x 584 x 1579 1002 x 824 x 1790 1002 x 824 x 1790 NOTE: For the conditions please refer to page 73. * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30RQ 017 021 026 033 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit supply A 75 95 118 118 Maximum start-up current (Un)* kW 7.8 9.1 11 13.8 Maximum operating power input** A 8 12 16 17 Nominal unit operating current draw*** * Maximum instantaneous start-up current (locked rotor current of the compressor). ** Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. Operating range Heating mode Cooling mode 53 40 48 Outside air temperature, °C Outside air temperature, °C 43 38 33 28 23 18 13 8 30 20 10 0 3 -10 -2 -7 -20 -12 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 15 24 Evaporator leaving water temperature, °C 20 25 30 35 40 45 50 Water heat exchanger leaving water temperature, °C Operating range with anti-freeze solution and Pro-Dialog configuration. 85 55 DUCTABLE AIR-TO-WATER HEAT PUMPS Heating Reversible 30RQY Options/accessories Features t )ZESPOJDNPEVMFPQUJPO t *OUFHSBUFEXBUFSmMMTZTUFNPQUJPO accessory) t *OMFUEVDUGSBNFPQUJPO t *OMFUmMUFSGSBNFPQUJPO t +#VT#BD/FUBOE-PO5BMLHBUFXBZT (accessory) t 3FNPUFJOUFSGBDFBDDFTTPSZ t $POEFOTBUFESBJOQBOBDDFTTPSZ t 'PVSTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOEOPNJOBM heating capacities from 17 to 31 kW. t "RVBTOBQIFBUQVNQTGPSDPNNFSDJBMBQQMJDBUJPOTTVDIBTUIFBJSDPOEJUJPOJOH of offices and hotels. t &YDFQUJPOBMMZIJHIFOFSHZFóDJFODZBUQBSUMPBE&VSPWFOUFOFSHZFóDJFODZ class A and B in cooling mode and C in heating mode (in accordance with EN14511-3:2013). t *OUFHSBUFTUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOTP[POFGSJFOEMZSFGSJHFSBOU3" scroll compressors, low-noise fans and auto-adaptive microprocessor control. t 6OJUTJODMVEFBIZESPOJDNPEVMFJOUFHSBUFEJOUPUIFDIBTTJTMJNJUJOHJOTUBMMBUJPOUP connection of power supply, water supply and return piping/air distribution ducting. t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 7FSUJDBMDPOEFOTFSDPJMTXJUIQSPUFDUJPOHSJMMFTPOBOUJWJCSBUJPONPVOUJOHT t -PXOPJTFGBOTOPXFWFORVJFUFS3JHJEGBOJOTUBMMBUJPOGPSSFEVDFETUBSUVQOPJTF t &BTZEVDUDPOOFDUJPOBOEGBOTXJUI1BBWBJMBCMFQSFTTVSF t 5IFVOJUIBTBTNBMMGPPUQSJOUBOEJTFODMPTFECZFBTJMZSFNPWBCMFQBOFMT t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 4ZTUFNBUJDPQFSBUJPOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPSTUFQ by-step verification of the instruments, electrical components and motors. t .BJOUFOBODFGSFFTDSPMMDPNQSFTTPSTBOEGBTUEJBHOPTJTPGQPTTJCMFJODJEFOUT and their history via the Pro-Dialog+ control reduce maintenance costs. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PSSPTJPOSFTJTUBODFUFTUTBDDFMFSBUFEBHFJOHUFTUPODPNQSFTTPSQJQJOHBOEGBO supports and transport simulation test on a vibrating table in the laboratory. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 86 Hydronic module, sizes 026-033 30RQY 017-033 Physical data 30RQY Air conditioning application as per EN14511-3 : 2013 Condition 1/condition 2 kW Nominal cooling capacity EER kW/kW Eurovent class, cooling (condition 1) ESEER (condition 1) kW/kW Heating application as per EN14511-3:2013 Condition 1/condition 2 kW Nominal heating capacity COP kW/kW Eurovent class, heating (condition 1) Operating weight* Standard unit (with hydronic module) kg Standard unit (without hydronic module) kg Refrigerant* Compressor Control Fans Air flow l/s Evaporator Condenser Unit with hydronic module Dimensions Length x depth x height mm 017 021 026 033 14.9/18.4 2.51/2.82 B 2.78 19.0/23.9 2.53/2.91 B 2.74 27.1/35.6 2.70/3.42 A 3.03 32.3/41.3 2.95/3.50 A 3.2 17.0/17.5 2.66/3.21 C 20.5/20.8 2.67/3.16 C 28.8/29.9 2.59/3.22 D 31.4/32.3 2.67/3.21 C 226 243 280 295 211 228 262 277 R-410A One scroll compressor Pro-Dialog+ Two twin-speed centrifugal fans, 5 backward-curved blades One twin-speed axial fan, 7 blades 1640 1640 3472 3472 One plate heat exchanger Copper tubes and aluminium fins One single-speed pump, screen filter, expansion tank, flow switch, water circuit drain valve, pressure gauge, automatic air purge valve, safety valve 1135 x 584 x 1608 1135 x 584 x 1608 1002 x 824 x 1829 1002 x 824 x 1829 NOTE: For the conditions please refer to page 73. * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30RQY 017 021 026 033 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit supply A 75 95 118 118 Maximum start-up current (Un)* kW 8.0 9.3 11.2 14.0 Maximum operating power input** A 13 16 20 24 Nominal unit operating current draw*** * Maximum instantaneous start-up current (locked rotor current of the compressor). ** Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. Operating range Cooling mode Heating mode 53 40 48 38 Outside air temperature, °C Outside air temperature, °C 43 33 28 23 18 13 8 3 30 20 10 0 -10 -2 -7 -20 -12 15 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 20 25 30 35 40 45 50 Water heat exchanger leaving water temperature, °C Evaporator leaving water temperature, °C Operating range with anti-freeze solution and Pro-Dialog configuration. 87 55 AIR-TO-WATER HEAT PUMPS Heating Reversible 30RQS Options Features t "JSIFBUFYDIBOHFSXJUIQSFUSFBUFE fins t 7FSZMPXOPJTFMFWFM t -PXMFBWJOHXBUFSUFNQFSBUVSF t 7FSZMPXMFBWJOHXBUFSUFNQFSBUVSF t 8JOUFSPQFSBUJPOJODPPMJOHNPEF t 4PGUTUBSUFS324 t 1BSUJBMIFBUSFDMBJN t 'SPTUQSPUFDUJPOEPXOUP¡$ t )JHIBOEMPXQSFTTVSFTJOHMFBOE dual-pump hydronic modules with or without expansion tank t )JHIQSFTTVSFWBSJBCMFTQFFETJOHMF or dual-pump hydronic modules with or without expansion tank t +#VT#BD/FUBOE-PO5BMLHBUFXBZT t 4DSFXPSXFMEFEXBUFSIFBU exchanger connection sleeves t .BTUFSTMBWFPQFSBUJPO t 3FNPUFJOUFSGBDF t 5XFMWFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOEOPNJOBM heating capacities from 42 to 158 kW. t "RVBTOBQIFBUQVNQTGPSDPNNFSDJBMPSJOEVTUSJBMBQQMJDBUJPOT t *ODSFBTFEFOFSHZFóDJFODZBUQBSUMPBE&VSPWFOUFOFSHZFóDJFODZDMBTT$ and D (in accordance with EN14511-3:2013) in cooling mode and B and C in heating mode. t *OUFHSBUFTUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOTP[POFGSJFOEMZSFGSJHFSBOU R-410A, scroll compressors, low-noise fans made of a composite material, autoadaptive microprocessor control, electronic expansion valve and variablespeed pump (option). t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 7FSUJDBMBJSIFBUFYDIBOHFSDPJMTXJUIQSPUFDUJPOHSJMMFTPOBOUJWJCSBUJPO mountings. t -PXOPJTF'MZJOH#JSE*7GBOTNBEFPGBDPNQPTJUFNBUFSJBM3JHJEGBO installation for reduced start-up noise. t 4NBMMVOJUGPPUQSJOUBOEBMPXIFJHIUNN FODMPTFECZFBTJMZSFNPWBCMF panels. t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 4ZTUFNBUJDPQFSBUJPOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPSTUFQ by-step verification of the instruments, electrical components and motors. t 4FWFSBMDPNQSFTTPSTDPOOFDUFEJOQBSBMMFM"UQBSUMPBEBSPVOEPGUIF time, only the compressors that are necessary operate, ensuring increased energy efficiency. t 5IFFMFDUSPOJDFYQBOTJPOEFWJDF&97 BMMPXTPQFSBUJPOBUBMPXFSDPOEFOTJOH pressure (EER optimisation), and dynamic superheat management optimises the utilisation of the water heat exchanger surface. t .BJOUFOBODFGSFFTDSPMMDPNQSFTTPSTBOEGBTUEJBHOPTJTPGQPTTJCMFJODJEFOUT and their history via the Pro-Dialog+ control reduce maintenance costs. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PSSPTJPOSFTJTUBODFUFTUTBDDFMFSBUFEBHFJOHUFTUPODPNQSFTTPSQJQJOHBOEGBO supports and transport simulation test on a vibrating table in the laboratory. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 88 30RQS 039-160 Physical data 30RQS Air conditioning application as per EN14511-3:2013 kW Nominal cooling capacity EER kW/kW Eurovent class, cooling ESEER kW/kW Heating application as per EN14511-3:2013 kW Nominal heating capacity COP kW/kW Eurovent class, heating Operating weight* Standard unit without hydronic module kg Standard unit with hydronic module Single high-pressure pump kg Dual high-pressure pump kg Compressors Circuit A/B Refrigerant* Capacity control Air heat exchangers Fans Quantity Total air flow (at high speed) l/s Water heat exchanger Hydronic module (option) Dimensions Length x depth x height mm 039 045 050 060 070 078 080 090 100 120 140 160 38 2.84 C 3.80 43 2.70 C 3.77 50 2.65 D 3.81 59 2.77 C 3.61 64 2.70 C 3.61 74 2.58 D 3.57 78 2.79 C 3.84 86 2.70 C 3.77 96 2.70 C 3.88 113 2.69 D 4.04 132 2.77 C 3.75 149 2.58 D 3.67 42 3.08 B 47 3.05 B 53 3.03 B 61 3.03 B 70 3.06 B 78 2.87 C 80 3.08 B 93 3.02 B 101 3.09 B 117 3.06 B 138 3.07 B 158 2.97 C 506 513 539 552 553 560 748 895 903 959 1060 1078 1099 1136 1117 1127 2/2 2/2 2 10600 2 10600 535 543 569 582 582 590 778 927 935 995 561 569 594 608 608 616 804 972 980 1043 Hermetic scroll compressors, 48.3 r/s 2/2/2/2/2/2/2/3/3/3/R-410A Pro-Dialog+ Grooved copper tubes and aluminium fins Axial Flying Bird IV with rotating shroud 1 1 1 1 1 1 2 2 2 2 3800 3800 3800 5300 5300 5300 7600 7600 7600 7600 Direct expansion, plate heat exchanger Single or dual pump, Victaulic screen filter, safety valve, expansion tank, purge valves (water and air), pressure sensors 1090 x 2109 x 1330 2273 x 2136 x 1330 NOTE: For the conditions please refer to page 73 * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30RQS without hydronic module 039 045 050 060 070 078 080 090 100 120 140 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit supply Maximum start-up current (Un)* Standard unit A 113.8 134.8 142.8 145.8 176.0 213.0 213.6 173.6 207.6 247.6 243.0 Unit with electronic starter option A 74.7 86.5 93.8 96.2 114.4 139.8 139.8 kW 19.5 22.3 24.5 27.9 31.2 35.8 35.6 42.3 45.6 52.5 62.4 Maximum operating power input** A 25.6 29.0 33.0 36.0 42.4 52.8 53.4 55.4 61.7 77.3 84.8 Nominal unit operating current draw*** * Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). ** Power input, compressors and fans, at the unit operating limits (saturated suction temp. 10°C, saturated condensing temp. 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: evaporator entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. Operating range Heating mode Cooling mode 60 Outside air temperature, °C Leaving water temperature, °C 55 50 45 40 35 30 25 Full load Minimum load 20 -20 Evaporator leaving water temperature, °C Full load Minimum load -10 0 10 20 30 Outside air temperature, °C 89 40 50 160 286.0 71.6 105.6 DUCTABLE AIR-TO-WATER HEAT PUMPS Heating Reversible 30RQSY Options Features t "JSIFBUFYDIBOHFSXJUIQSFUSFBUFE fins t 7FSZMPXOPJTFMFWFM t 4VDUJPOmMUFST324: t 4PGUTUBSUFS324: t 1BSUJBMIFBUSFDMBJN t 'SPTUQSPUFDUJPOEPXOUP¡$ t )JHIBOEMPXQSFTTVSFTJOHMFBOE dual-pump hydronic modules with or without expansion tank t )JHIQSFTTVSFWBSJBCMFTQFFETJOHMF or dual-pump hydronic modules with or without expansion tank t +#VT#BD/FUBOE-PO5BMLHBUFXBZT t 4DSFXPSXFMEFEXBUFSIFBU exchanger connection sleeves t .BTUFSTMBWFPQFSBUJPO t 3FNPUFJOUFSGBDF t 5XFMWFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOEOPNJOBM heating capacities from 42 to 159 kW. t %VDUBCMF"RVBTOBQIFBUQVNQTGPSDPNNFSDJBMPSJOEVTUSJBMBQQMJDBUJPOT6OJUT include inverter fans to maximise EERs and COPs at all operating conditions. t &VSPWFOUFOFSHZFóDJFODZDMBTT"BOE#JODPPMJOHNPEFBOE"JOIFBUJOH mode (in accordance with EN14511-3: 2013) t *OUFHSBUFTUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOTP[POFGSJFOEMZSFGSJHFSBOU R-410A, scroll compressors, low-noise fans made of a composite material, autoadaptive microprocessor control, electronic expansion valve and variablespeed pump (option). t "WBJMBCMFTUBUJDQSFTTVSFPGVQUP1BGPSTJ[FTUPBOEUP and up to 180 Pa for sizes 060 to 078 and 140 to 160. t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM t 7FSUJDBMBJSIFBUFYDIBOHFSTXJUIQSPUFDUJPOHSJMMFTPOBOUJWJCSBUJPONPVOUJOHT t -PXOPJTF'MZJOH#JSE*7GBOTNBEFPGBDPNQPTJUFNBUFSJBM3JHJEGBO installation for reduced start-up noise. t 4NBMMVOJUGPPUQSJOUBOEBMPXIFJHIUNN FODMPTFECZFBTJMZSFNPWBCMF panels. t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 4ZTUFNBUJDPQFSBUJPOUFTUCFGPSFTIJQNFOUBOERVJDLUFTUGVODUJPOGPSTUFQ by-step verification of the instruments, electrical components and motors. t 4FWFSBMDPNQSFTTPSTDPOOFDUFEJOQBSBMMFM"UQBSUMPBEBSPVOEPGUIF time, only the compressors that are necessary operate, ensuring increased energy efficiency. t 5IFFMFDUSPOJDFYQBOTJPOEFWJDF&97 BMMPXTPQFSBUJPOBUBMPXFSDPOEFOTJOH pressure (EER and COP optimisation), and dynamic superheat management optimises the utilisation of the water heat exchanger surface. t .BJOUFOBODFGSFFTDSPMMDPNQSFTTPSTBOEGBTUEJBHOPTJTPGQPTTJCMFJODJEFOUT and their history via the Pro-Dialog+ control reduce maintenance costs. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PSSPTJPOSFTJTUBODFUFTUTBDDFMFSBUFEBHFJOHUFTUPODPNQSFTTPSQJQJOHBOEGBO supports and transport simulation test on a vibrating table in the laboratory. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 90 30RQSY 039-160 Physical data 30RQSY Air conditioning application as per EN14511-3:2013 Nominal cooling capacity kW EER kW/kW Eurovent class, cooling ESEER kW/kW Heating application as per EN14511-3:2013 kW Nominal heating capacity COP kW/kW Eurovent class, heating Operating weight* Standard unit without hydronic module kg Standard unit with hydronic module Single high-pressure pump kg Dual high-pressure pump kg Compressors Circuit A/B Refrigerant* Capacity control Air heat exchangers Fans Quantity Total air flow (at high speed) l/s Water heat exchanger Hydronic module (option) Dimensions** Length x depth x height mm 039 045 050 060 070 078 080 090 100 120 140 160 37 2.91 A 3.98 43 2.82 A 4.08 50 2.72 A 3.95 58 2.81 A 3.87 63 2.71 A 3.82 73 2.59 B 3.75 78 2.84 A 3.89 86 2.74 A 3.79 96 2.75 A 3.94 113 2.75 A 4.15 130 2.78 A 4.27 147 2.58 B 4.19 42 3.13 A 47 3.11 A 53 3.01 A 62 3.15 A 70 3.15 A 78 3.00 A 80 2.20 A 93 3.06 A 101 3.03 A 117 3.06 A 139 3.12 A 159 3.00 A 521 528 559 573 573 580 762 930 939 994 1090 1107 1129 1166 1146 1183 2/2 2/2 2 9200 2 9200 551 558 588 602 603 610 792 961 971 1030 577 584 614 628 629 636 818 1006 1016 1078 Hermetic scroll compressors. 48.3 r/s 2/2/2/2/2/2/2/3/3/3/R-410A Pro-Dialog+ Grooved copper tubes and aluminium fins Axial Flying Bird IV with rotating shroud 1 1 1 1 1 1 2 2 2 2 3800 3800 4600 4600 4600 7600 7600 7600 7600 3800 Direct expansion, plate heat exchanger Single or dual pump, Victaulic screen filter, safety valve, expansion tank, purge valves (water and air), pressure sensors 2109 x 1132/1297 x 1371 2142/2307 x 1132/1297 x 1371 2273 x 2122 x 1371 NOTE: For the conditions please refer to page 73 * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. ** The first value is for units without filter frame, and the second value is for units with option 23B and filter frame. Electrical data 30RQSY without hydronic module Power circuit Nominal power supply Control circuit supply Maximum start-up current (Un)* Standard unit Unit with electronic starter option Maximum operating power input** Nominal unit operating current draw*** * ** *** 039 045 050 V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer A A kW A 116.40 74.70 21.20 28.20 137.40 86.50 24.00 31.60 145.40 93.80 26.20 35.60 060 070 078 080 090 100 120 140 160 148.40 96.20 29.60 38.60 176.40 114.40 31.80 42.80 213.40 143.30 36.40 53.20 218.80 148.80 39.00 58.60 178.80 45.70 60.60 212.80 49.00 66.90 252.80 55.90 82.50 243.80 63.60 85.60 286.80 72.80 106.40 Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Power input, compressors and fans, at the unit operating limits (saturated suction temp. 10°C, saturated condensing temp. 65°C) and nominal voltage of 400 V (data given on the unit nameplate). Standardised Eurovent conditions: evaporator entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. Heating mode Operating range Cooling mode Leaving water temperature, °C Outside air temperature, °C 50 40 30 20 10 0 60 55 50 45 40 35 30 -10 25 -20 0 5 10 15 20 Evaporator leaving water temperature, °C 20 -20 25 Full load Minimum load 91 -10 0 10 20 30 Outside air temperature, °C 40 50 AIR-TO-WATER HEAT PUMPS WITH INTEGRATED HYDRONIC MODULE Heating Reversible 30RQ Options Features t &VSP1BDLFODMPTVSFQBOFMTXBUFS heat exchanger frost protection, main disconnect switch and low noise level t "JSIFBUFYDIBOHFSDPSSPTJPO protection t 6OJUTGPSJOEPPSJOTUBMMBUJPOXJUI discharge ducts t -PXOPJTFMFWFMT t (SJMMFTPOBMMGPVSVOJUGBDFT t &ODMPTVSFQBOFMTPOFBDIFOEPGDPJMT t 8JOUFSPQFSBUJPO t 8BUFSIFBUFYDIBOHFSGSPTUQSPUFDUJPO t 8BUFSIFBUFYDIBOHFSBOEIZESPOJD module frost protection t 1BSUJBMIFBUSFDMBJN t .BTUFSTMBWFPQFSBUJPO t .BJOEJTDPOOFDUTXJUDIXJUIPS without fuse (302-522) t 8BUFSIFBUFYDIBOHFSBMM PSXBUFS heat exchanger and hydronic module (302-522) with aluminium jacket t )JHIBOEMPXQSFTTVSFTJOHMFPS dual-pump hydronic modules t +#VT#BD/FUPS-PO5BMLHBUFXBZT t &OFSHZ.BOBHFNFOU.PEVMF&.. t 4BGFUZWBMWFXJUIUISFFXBZWBMWF fitted t $POGPSNTUP"VTUSBMJBODPEFT t 6OJUTUPSBHFBCPWF¡$ t $PJMEFGSPTUSFTJTUBODFIFBUFST t 5SBEJUJPOBM$V"MDPJMT t 4IFMMBOEUVCFXBUFSIFBUFYDIBOHFS t $POOFDUJPOTMFFWF t 1PXFSDBCMFDPOOFDUJPOTJEF extension (302-522) t &MFDUSPOJDTUBSUFS t &MFWFOTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOEOPNJOBM heating capacities from 181 to 554 kW. t 4UBUFPGUIFBSU"RVBTOBQIFBUQVNQTGFBUVSJOHUIFMBUFTUUFDIOPMPHJDBM innovations and operating on the ozone-friendly refrigerant R-410A. t *OUFHSBUFEIZESPOJDNPEVMFXJUIXBUFSQVNQBOEFYQBOTJPOUBOL t -PXOPJTFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFMT t 7TIBQFEBJSIFBUFYDIBOHFSDPJMTBMMPXJOHRVJFUFSBJSnPXBDSPTTUIFDPJM t -PXOPJTFUIHFOFSBUJPO'MZJOH#JSEGBOTOPXFWFORVJFUFS3JHJEGBO installation prevents start-up noise. t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 'BTUDPNNJTTJPOJOHBTBMMVOJUTBSFTZTUFNBUJDBMMZSVOUFTUFECFGPSFTIJQNFOU t &DPOPNJDBMPQFSBUJPOXJUIJODSFBTFEFOFSHZFóDJFODZBUQBSUMPBEBOE dynamic superheat management. t -FBLUJHIUSFGSJHFSBOUDJSDVJUBOESFEVDFENBJOUFOBODFDPTUT t "VUPBEBQUJWFDPOUSPMBMHPSJUINBOEBVUPNBUJDDPNQSFTTPSVOMPBEJOHGPS increased reliability. t &YDFQUJPOBMFOEVSBODFUFTUT A B A B Pro-Dialog Plus operator interface 92 30RQ 182-522 Physical data, 30RQ 182-262 “B” + 30RQ 302-522 units 30RQ 182-262 “B” + 30RQ 302-522 Air conditioning application as per EN14511-3:2013 kW Nominal cooling capacity EER kW/kW Eurovent class, cooling ESEER kW/kW Heating application as per EN14511-3:2013 kW Nominal heating capacity COP kW/kW Eurovent class, heating kg Operating weight - standard unit* Compressors Refrigerant* Capacity control Air heat exchangers Fans Quantity Total air flow l/s Water heat exchanger Dimensions Length x depth x height mm NOTE: For the conditions please refer to page 73 * 182 202 232 262 302 342 372 402 432 462 522 177 2.93 B 3.97 198 2.70 C 3.68 217 2.84 C 4.18 250 2.62 D 3.67 279 2.63 D 4.03 309 2.46 E 3.75 333 2.63 D 3.50 368 2.49 E 3.54 392 2.59 D 3.61 435 2.59 D 3.43 470 2.40 E 3.25 184 205 221 268 2.85 2.83 2.98 2.85 C C C C 1683 1785 1820 2020 Hermetic scroll, 48.3 r/s R-410A Pro-Dialog Plus Grooved copper tubes and aluminium fins Axial Flying Bird 4 fans with rotating shroud 4 4 4 4 303 2.73 D 2799 336 2.79 D 2986 367 2.84 C 3079 408 2.74 D 3233 446 2.79 D 3669 507 2.79 D 3909 554 2.72 D 4083 5 5 6 6 7 8 8 18056 18056 18056 Twin-circuit plate heat exchanger 22569 22569 27083 27083 31597 Direct-expansion twin-circuit. shell-and-tube heat exchanger 36111 36111 18056 2457 x 2253 x 2297 3604 x 2253 x 2297 4798 x 2253 x 2297 Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data, 30RQ 182-262 “B” + 30RQ 302-522 units 30RQ (without hydronic module) 182 202 232 262 302 342 372 402 432 462 522 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V, via internal transformer Control circuit supply kW Maximum power input* - circuits A + B/C 85 98 102 127 140 159 166 191 204 229 255 A Nominal current draw** - circuits A + B/C 113 129 135 167 185 209 219 251 269 302 334 Maximum start-up current*** - circuits A + B/C A 353 375 348 426 448 481 492 536 558 601 645 * Power input of the compressor(s) + fan(s) at maximum unit operating conditions saturated suction temperature 10°C, saturated condensing temperature 65°C at 400 V nominal voltage (values given on the unit name plate). ** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C *** Maximum instantaneous starting current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Cooling mode Heating mode Entering air temperature, °C Entering air temperature, °C Operating range Leaving water temperature, °C Leaving water temperature, °C Note: Water heat exchanger and air heat exchanger Δt = 5 K Operating range, standard unit Operating range, unit equipped with option 28 (winter operation). In addition the unit must either be equipped with the frost protection option for the water heat exchanger and the hydronic module (if used), or the water loop must be protected against frost by the installer, using an anti-freeze solution. 93 WATER-SOURCE HEAT PUMPS Heating Heating 61WG Options/accessories Features t t t t t t &MFWFOTJ[FTXJUIOPNJOBMIFBUJOHDBQBDJUJFTGSPNUPL8 t "RVBTOBQIFBUQVNQTEFTJHOFEGPSDPNNFSDJBMPóDFTIPUFMTFUD SFTJEFOUJBM (houses, apartments etc.) or industrial applications (domestic hot-water production etc.). t 0QUJNJTFEGPSIFBUJOHBQQMJDBUJPOTMFBWJOHXBUFSUFNQFSBUVSFVQUP¡$XJUIPVU auxiliary heating), evaporator temperature down to -5°C and a COP of above 5. t 6OJUTBSFFRVJQQFEXJUIUIFMBUFTUHFOFSBUJPO3"TDSPMMDPNQSFTTPS optimised for high-performance. t -BSHFOVNCFSPGPQUJPOTIZESPOJDLJUTXJUIPSXJUIPVUWBSJBCMFXBUFSnPXSBUF reinforced sound insulation, stacking and connection of two units, or operation with low-temperature glycol solution down to -12°C. Unique combination of high performance and functionality in an exceptionally compact chassis. t 5IFIJHIUFNQFSBUVSFNBLFTUIFTFVOJUTDPNQBUJCMFXJUINPTUIFBUTPVSDFT both in new and refurbished buildings and permits domestic hot water production in significant quantities (dual setpoint). t 6OJUTVTFXFBUIFSDPNQFOTBUJPODPOUSPMBOEDPOUSPMGPVSTVQQMFNFOUBSZ electric heating stages or a relief boiler. t $PNQMFUFIZESPOJDLJUGPSCPUIFWBQPSBUPSBOEDPOEFOTFSXJUIEJòFSFOUMFWFMTPG available pressure, with variable or fixed speed. t /FFEMFWBMWFDPOUSPMGPSFBTJFSUSBOTJUJPOGSPNUIFDPNGPSUNPEFUPEPNFTUJD hot water production using a collection tank (not supplied). t 3FWFSTJCJMJUZCZXBUFSnPXJOWFSTJPOJOUIFTZTUFN t 1SP%JBMPHDPOUSPMBOEDPNQBUJCJMJUZXJUIUIF"RVBTNBSUTZTUFN t 6OJUTBWBJMBCMFXJUIDPOOFDUJPOTBUUIFUPQPSBUUIFSFBS t &BTZJOTUBMMBUJPOTNBMMGPPUQSJOUJEFBMGPSSFGVSCJTIFECVJMEJOHTBMMPXTBDDFTT in very tight plant rooms. t 5IFWBSJBCMFXBUFSnPX78' UFDIOPMPHZPGUIFWBSJBCMFnPXQVNQPQUJNJTFT system operation and enhances energy efficiency. t 4UBOEBSEMPXTPVOEMFWFMBMMPXTJOTUBMMBUJPOJOBOZCVJMEJOHUZQF t t t t t t t t t t 4PGUTUBSUFS .BTUFSTMBWFPQFSBUJPO &YUFSOBMEJTDPOOFDUIBOEMF $POEFOTFSJOTVMBUJPO -PXPSIJHIQSFTTVSFmYFEPS variable-speed single-pump hydronic module, evaporator side* -PXPSIJHIQSFTTVSFmYFEPS variable-speed single-pump hydronic module, condenser side* +#VT#BD/FUBOE-0/HBUFXBZT #VJMUJO%)8TQBDFIFBUJOHDPOUSPM )JHIUFNQFSBUVSFXBUFSQSPEVDUJPO condenser side, with glycol solution on the evaporator side* -PXTPVOEMFWFM 6OJUTTUBDLBCMF $VTUPNFSXBUFSDPOOFDUJPOBUUIF top of the unit* &WBQPSBUPSBOEDPOEFOTFSTDSFXPS welded connection sleeves* 3FNPUFVTFSJOUFSGBDF )FBUJOH4ZTUFN.BOBHFSUZQFT"# and C: control of comfort heating (one or more zones) and domestic hot water production in installations where the 61WG is backed up by auxiliary boilers, electric resistance heaters or a district heating system** * Option p ** Accessoryy \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 94 61WG Physical data 61WG Heating application as per EN14511-3 : 2013 - condition 1 kW Heating capacity COP kW/kW Eurovent class Heating application as per EN14511-3 : 2013 - condition 2 kW Heating capacity COP kW/kW Eurovent class kg Operating weight Compressors Quantity Number of capacity stages Minimum capacity % Dimensions, standard unit** Width mm Depth mm Height mm Refrigerant* Control Evaporator Condenser 020 025 030 035 040 045 050 060 070 080 090 27.7 4.35 B 33.1 4.34 B 36.7 4.20 B 42.7 4.27 B 48.7 4.32 B 54.8 4.36 B 66.4 4.51 A 75.7 4.32 B 84.2 4.35 B 95.3 4.27 B 109 4.31 B 38.3 5.21 A 200 44.2 5.29 A 207 50.2 5.34 A 212 57.2 5.32 A 220 68.6 5.49 A 386 78.2 5.36 A 392 88.4 5.46 A 403 100 5.28 A 413 117 5.33 A 441 1 1 100 1 1 100 1 1 100 1 1 100 2 2 50 2 2 50 2 2 50 2 2 50 2 2 50 600 1044 901 600 1044 901 880 1474 901 880 1474 901 880 1474 901 880 1474 901 880 1474 901 29.0 34.4 5.42 5.29 A A 191 200 Hermetic scroll 48.3 r/s 1 1 1 1 100 100 600 600 600 600 1044 1044 1044 1044 901 901 901 901 R-410A Pro-Dialog+ Direct-expansion plate heat exchanger Plate heat exchanger NOTE: For the conditions please refer to page 73 * ** Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. The dimensions shown are for the standard unit. For other unit types please refer to the dimensional drawings. Electrical data 61WG Power circuit Nominal voltage Control circuit supply Maximum start-up current draw (Un)* Standard unit Unit with electronic starter option Maximum operating power input** Maximum operating current draw (Un)*** * ** *** 020 025 030 V-ph-Hz 400-3-50 ± 10% 24 V, via internal transformer A A kW A 98 53.9 9.7 16.1 142 78.1 11.4 19.6 142 78.1 12.7 21.1 035 040 045 050 060 070 080 090 147 80.9 14.6 24.4 158 86.9 16.5 26.7 197 108.4 18.6 30.9 162 98 22.8 39.2 163 99 25.4 42.2 171 105 29.2 48.8 185 114 33 53.4 228 139 37.2 61.8 Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Maximum power input at the unit operating limits. Maximum unit operating current at maximum unit power input and 400 V. Condenser leaving water temperature, °C Operating range 65 60 55 50 45 40 35 30 25 20 15 \\MAINMENU\STATUS Option 272 CAPB_T DEM_LIM SP CTRL_PNT EMSTOP Standard 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface -8 -6 -4 -2 0 2 4 6 8 10 12 14 Evaporator leaving water temperature, °C 16 18 20 61WG standard unit 61WG unit with option 272 (brine to water) Option 272: Condenser-side high-temperature water production, with glycol solution on the evaporator side 95 WATER-TO-WATER HEAT PUMPS Heating Heating 30XWH Options/accessories Features t .FEJVNBOEMPXUFNQFSBUVSF applications t 6OJUTVQQMJFEJOUXPBTTFNCMFEQBSUT t /PEJTDPOOFDUTXJUDICVUXJUITIPSU circuit protection t 4JOHMFQPXFSDPOOFDUJPOQPJOU t &WBQPSBUPSDPOEFOTFSQVNQFMFDUSJDBM power/control circuit options t 4FSWJDFWBMWFTFU t &WBQPSBUPSDPOEFOTFSBSSBOHFNFOU with one pass t $POEFOTFSJOTVMBUJPO t CBSFWBQPSBUPSBOEDPOEFOTFS t 3FWFSTFEFWBQPSBUPSXBUFS connections t +#VT#BD/FUBOE-0/HBUFXBZT t 7BSJPVTDPOEFOTJOHUFNQFSBUVSF options t &OFSHZ.BOBHFNFOU.PEVMF&.. t $PEFDPNQMJBODFGPS4XJU[FSMBOE and Australia t .BTUFSTMBWFPQFSBUJPO t 5PVDI4DSFFOJOUFSGBDF t -PXOPJTFMFWFME#" DPNQBSFE to standard unit) t 5IFSNBMDPNQSFTTPSJOTVMBUJPO t 8BUFSDPOOFDUJPOLJUGPSXFMEFE or flanged evaporator/condenser connections t 5XFOUZTUBOEBSEFóDJFODZTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUP 1732 kW and nominal heating capacities from 317 to 1969 kW and eleven high-efficiency sizes with nominal cooling capacities from 509 to 1756 kW and nominal heating capacities from 584 to 1989 kW. t 5IFQSFNJVNTPMVUJPOGPSJOEVTUSJBMBOEDPNNFSDJBMBQQMJDBUJPOTUIBUSFRVJSF optimal performances and maximum quality. t 5XPWFSTJPOT98GPSBJSDPOEJUJPOJOHBOESFGSJHFSBUJPOBQQMJDBUJPOTTFF separate entry), and 30XWH for heating applications. t 5XPFóDJFODZDMBTTFTUIFTUBOEBSEFóDJFODZ98)PòFSTBOPQUJNJTFE balance of technical and economical aspects and superior energy efficiency, whilst the high-efficiency 30XWHP offers unequalled energy efficiency at minimised operating cost. t 5XJOSPUPSTDSFXDPNQSFTTPSTXJUIIJHIFóDJFODZNPUPSBOEBWBSJBCMF capacity valve for exact matching of the cooling capacity to the load. t 6TFPG3BSFGSJHFSBOUXJUI[FSPP[POFEFQMFUJPOQPUFOUJBM t 1SP%JBMPHDPOUSPMTZTUFN t 'MPPEFENFDIBOJDBMMZDMFBOBCMFIFBUFYDIBOHFST t &YDFQUJPOBMGVMMBOEQBSUMPBEFOFSHZFóDJFODZ t &DPOPNJ[FSTZTUFNXJUIFMFDUSPOJDFYQBOTJPOEFWJDFGPSJODSFBTFEDPPMJOH capacity (30XWHP). t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 6OJUTBSFSVOUFTUFECFGPSFTIJQNFOUBOEJODMVEFBRVJDLUFTUGVODUJPOGPS fast commissioning. t -FBLUJHIUSFGSJHFSBOUDJSDVJU t $PNQSFIFOTJWFFOEVSBODFUFTUT t "RVBGPSDFPòFSTNVMUJQMFSFNPUFDPOUSPMNPOJUPSJOHBOEEJBHOPTUJDQPTTJCJMJUJFT \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 % 100 % 4.2 °C -28.9 °C dsable Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 96 Touch-screen Pro-Dialog operator interface 30XWH Physical data Standard-efficiency units 30XWH 254 304 354 Air conditioning application as per EN14511-3 : 2013 kW Nominal cooling capacity 273 307 359 EER kW/kW 5.32 5.30 5.24 ESEER kW/kW 5.67 5.58 5.58 Heating application as per EN14511-3 : 2013 kW Nominal heating capacity 317 358 421 COP kW/kW 4.59 4.57 4.61 kg Operating weight* 2017 2036 2072 Dimensions Depth mm 928 928 928 Length mm 2724 2724 2724 Height mm 1567 1567 1567 402 452 552 602 652 702 802 852 1002 1052 1154 1252 1352 1452 1552† 1652† 1702† 459 5.21 5.75 473 5.35 5.77 532 5.21 5.78 538 5.17 5.66 677 5.39 6.06 730 5.30 6.02 792 5.19 5.79 839 5.39 5.94 1017 1060 5.26 5.20 6.3 6.34 1141 5.30 6.23 1257 5.69 6.73 1342 5.51 6.44 1453 5.36 6.27 1547 5.29 6.06 1657 5.59 6.62 1732 5.60 6.56 516 4.54 2575 529 599 632 4.59 4.47 4.52 2575 2613 2644 751 4.56 3247 813 4.49 3266 887 4.46 3282 967 4.64 3492 1138 1190 4.48 4.42 5370 5408 1320 4.54 5698 1384 4.73 7066 1481 4.57 7267 1612 4.46 7305 1717 4.41 7337 1891 4.67 8681 1969 4.68 8699 936 2741 1692 936 936 936 2741 2741 2741 1692 1692 1692 1040 3059 1848 1040 3059 1848 1040 3059 1848 1042 2780 1898 1036 1036 4025 4025 1870 1870 1036 4025 1925 1156 4730 2051 1156 4730 2051 1156 4730 2051 1156 4730 2051 1902 4790 1515 1902 4790 1515 High-efficiency units 30XW-P 512 562 712 812 862 1012 1162 Air conditioning application as per EN14511-3 : 2013 kW Nominal cooling capacity 509 577 737 786 861 1039 1157 EER kW/kW 5.71 5.64 5.83 5.62 5.65 5.73 5.78 ESEER kW/kW 6.07 6.12 6.41 6.24 6.17 6.71 6.79 Heating application as per EN14511-3 : 2013 kW Nominal heating capacity 583 662 842 904 982 1191 1320 COP kW/kW 4.91 4.84 4.97 4.80 4.85 4.90 4.86 kg 2981 3020 3912 3947 3965 6872 6950 Operating weight* 3059 x 936 x 1743 3290 x 1069 x 1950 4730 x 1039 x 1997 Dimensions, length x depth x height mm Physical data for all units Semi-hermetic 06T screw compressors, 50 r/s Compressors R-134a Refrigerant Pro-Dialog, electronic expansion valves (EXV) Capacity control Flooded multi-pipe type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections Evaporator Flooded multi-pipe type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections Condenser 1314 1464 1612† 1762† 1323 5.80 6.65 1452 5.58 6.36 1626 5.87 6.8 1756 5.79 6.59 1509 1663 4.89 4.71 7542 7752 4730 x 1162 x 2051 1846 1989 4.89 4.87 10910 10946 4832 x 2129 x 1562 NOTE: For the conditions please refer to page 73. † These models are not Eurovent certified, as they are out of Eurovent certification program scope. * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data Standard-efficiency units 30XW-Nominal power supply, all units V-ph-Hz Control circuit, all units Maximum start-up current* Circuit A/circuit B A Maximum power input** Circuit A/circuit B kW Maximum current drawn (Un)** Circuit A/circuit B A 254 304 354 402 452 400-3-50 ± 10% 24 V via the built-in transformer 552 602 652 702 802 852 1002 1052 1154 1252 1352 1452 1552 1652 1702 233/- 233/- 303/- 414/- 414/- 414/- 414/- 587/- 587/- 587/- 587/- 414/414 414/414 414/414 587/414 587/587 587/587 587/587 587/587 587/587 76/- 89/- 97/- 128/- 135/- 151/- 151/- 184/- 200/- 223/- 223/- 150/135 151/151 151/151 184/151 184/184 200/200 223/223 223/202 223/223 123/- 145/- 160/- 206/- 217/- 242/- 242/- 295/- 317/- 351/- 351/- 242/217 242/242 242/242 295/242 295/295 317/317 351/351 351/317 351/351 High-efficiency units 30XW-P 512 562 712 812 862 1012 1162 1314 1464 1612 1762 Maximum start-up current* Circuit A/B A 414/414/587/587/587/414/414 414/414 587/414 587/587 587/587 587/587 Maximum power input** Circuit A/B kW 135/151/184/200/223/134/134 151/151 184/151 184/184 200/200 223/223 Maximum current drawn (Un)** Circuit A/B A 217/242/295/317/351/217/217 242/242 295/242 295/295 317/317 351/351 * Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at operation with maximum unit power input. ** Values obtained at operation with maximum unit power input. Values given on the unit name plate. Operating range, option 150 70 From approx. 45% to full load Part load limit approx. 35% Minimum load limit approx. 15% 55 50 Condenser leaving water temperature, °C Condenser leaving water temp., °C Operating range, standard units 45 40 35 30 25 20 15 0 5 10 15 From approx. 60% to full load Part load limit approx. 50% Minimum load limit approx. 30% 65 60 55 50 45 40 35 30 25 20 0 5 10 15 20 Evaporator leaving water temperature, °C 20 Evaporator leaving water temp., °C 97 WATER-TO-WATER HEAT PUMPS Heating 30XWHV Options Features t $POEFOTFSJOTVMBUJPO t 4FSWJDFWBMWFTFU t &WBQPSBUPSDPOEFOTFSQVNQFMFDUSJDBM power/control circuit options t 3FWFSTFEFWBQPSBUPSBOEPS condenser water connections t &WBQPSBUPSBOEPSDPOEFOTFSXJUI one pass t CBSFWBQPSBUPSBOEPSDPOEFOTFS t +#VT#BD/FUPS-0/HBUFXBZT t "EEJUJPOBMNPEVMFGPSDPNNVOJDBUJPO with BacNet protocol via Ethernet (IP) t $POEFOTJOHUFNQFSBUVSFMJNJUBUJPO t $POUSPMGPSMPXDPOEFOTJOH temperature systems t &OFSHZ.BOBHFNFOU.PEVMF&.. t -FBLEFUFDUJPO t $PEFDPNQMJBODFGPS4XJU[FSMBOEJO addition to PED code t $PEFDPNQMJBODFGPS"VTUSBMJB t -PXOPJTFMFWFME#" DPNQBSFE to standard unit) t 8FMEFEFWBQPSBUPSBOEPSDPOEFOTFS water connection kit t 'MBOHFEFWBQPSBUPSBOEPSDPOEFOTFS water connection kit t 5IFSNBMDPNQSFTTPSJOTVMBUJPO t &.$DMBTTJmDBUJPOBDDPSEJOHUP*&$ 61800-3 - class C2 t .BTUFSTMBWFPQFSBUJPO t 4JOHMFQPXFSDPOOFDUJPOQPJOU (1150-1710) t /JOFTJ[FTGPSDPNNFSDJBMBOEJOEVTUSJBMBQQMJDBUJPOTXJUIOPNJOBMIFBUJOH capacities from 648 to 1932 kW. t 5IFVOJUTGFBUVSFFYDMVTJWFJOWFSUFSESJWFOTDSFXDPNQSFTTPSTBOFWPMVUJPO of the proven traditional Carrier twin-rotor screw compressor design. t 6OJUTDBOQSPWJEFVQUP¡$POUIFDPOEFOTFSTJEF t 98)7VOJUTBSFEFTJHOFEGPSIJHIQFSGPSNBODFCPUIBUGVMMMPBEBOEBU part load with COPs up to 4.6 and Eurovent energy class ratings A and B. t /FXJOOPWBUJWF5PVDI1JMPUTNBSUDPOUSPMGPSWBSJBCMFESJWFTDSFXDPNQSFTTPS units uses an intuitive, user-friendly interface with concise, clear information in a choice of languages. t $PNQMJBODFXJUI*&$DMBTT$ t *OWFSUFSESJWFOUXJOSPUPSTDSFXDPNQSFTTPSTBMMPXQSFDJTFDBQBDJUZNBUDIJOH of building load changes and significantly reduce unit power input, especially at part-load. t 'MPPEFENFDIBOJDBMMZDMFBOBCMFIFBUFYDIBOHFST t $PNQBDUEFTJHOBOETJNQMJmFEFMFDUSJDBMBOEXBUFSDPOOFDUJPOTGPSFBTZ installation. t 3BSFGSJHFSBOUXJUI[FSPP[POFEFQMFUJPOQPUFOUJBM t -FBLUJHIUSFGSJHFSBOUDJSDVJU t .JOJNJTFEPQFSBUJOHTPVOEMFWFMBUQBSUMPBE t *NQSPWFEFMFDUSJDBMQFSGPSNBODF Touch Pilot operator interface 98 30XWHV Physical data 30XWHV Heating application - as per EN14511-3 : 2013 Condition 1 Heating capacity COP Eurovent class, heating Condition 2 Heating capacity COP Eurovent class, heating Operating weight* Dimensions Length x depth x height Compressor Quantity, circuit A/B Capacity control Minimum capacity Refrigerant* Evaporator Condenser 580 630 810 880 1150 1280 1470† 1570† 1710† kW kW/kW 648 4.64 A 719 4.53 A 890 4.56 A 974 4.43 B 1261 4.62 A 1428 4.61 A 1594 4.55 N.A 1761 4.33 N.A 1932 4.16 N.A kW kW/kW 687 6.15 A 3152 767 5.98 A 3190 956 5.96 A 4157 1021 5.81 A 4161 1335 6.05 A 7322 1524 6.00 A 7398 1712 5.82 N.A 7574 1898 5.49 N.A 7770 2067 5.34 N.A 7808 kg mm % 3059 x 1087 x 1743 3290 x 1237 x 1950 4730 x 1164 x 1997 4730 x 1255 x 2051 Semi-hermetic 06T screw compressor, 60 r/s 1/1/1/1/1/1 1/1 1/1 1/1 Touch Pilot, inverter-driven compressor. electronic expansion valve (EXV) 20 20 20 20 10 10 10 10 R-134a Flooded multi-tube type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections Flooded multi-tube type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections 1/1 10 NOTE: For the conditions please refer to page 73. † These models are not Eurovent certified, as they are out of Eurovent certification program scope. * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data 30XWHV Power circuit Nominal voltage Control circuit supply Start-up current* Maximum power factor Maximum power input, circuit A/B*** Eurovent current draw, circuit A/B** Maximum current draw (Un), circuit A/B*** * ** *** 580 V-ph-Hz kW A A 630 810 880 400-3-50 ± 10% 24 V, via internal transformer Negligible (lower than maximum current drawn) 0.91-0.93 0.91-0.93 0.91-0.93 0.91-0.93 155/193/222/246/175/200/240/265/270/330/380/421/- 1150 1280 1470 1570 1710 0.91-0.93 155/155 175/175 270/270 0.91-0.93 193/193 200/200 330/330 0.91-0.93 222/193 240/200 380/330 0.91-0.93 222/222 240/240 380/380 0.91-0.93 246/246 265/265 421/421 Instantaneous start-up current Eurovent unit operating conditions: evaporator entering/leaving water temperature 12°C/7°C, condenser entering/leaving water temperature 30°C/35°C. Values obtained at operation with maximum unit power input. Values given on the unit name plate. Operating range Condenser leaving water temperature, °C 55 From approximately 50% to full load Part-load limit approximately 50% Minimum load limit 50 45 40 35 30 25 20 15 0 5 10 15 20 Evaporator leaving water temperature, °C 99 Air treatment Index System architecture 100 Index Hybrid Terminal Range Type 36XB Cooling capacity, kW 0.27-2 Heating capacity, kW 0.25-8 Fresh Air flow, Page l/s 8-42 102 Chilled-water terminal units Type Cassette X Range Cooling capacity, Heating capacity, kW kW Air flow, l/s Page 42GW 42N 42EM 42DW 42BJ 42GM 42GR 1.6-8.7 0.8-6.4 0.7-6.8 4.4-11.7 0.5-4.9 2.2 3.1 2.2-14.5 1.1-9.5 1.1-7.8 6.5-19.8 0.5-5.8 1.7 2.9-3.5 100-400 35-422 66-237 220-726 16-200 94 103-109 104 106 108 110 112 114 116 Heating capacity, kW - Air flow, l/s 28-180 19-173 47-236 19-78 Page Cabinet Concealed Ducted X X X X X X X Air systems and terminal units Type Linear air diffusers: Moduboot System-powered linear VAV air diffusors: Moduline Range Cooling capacity, kW 35BD/SR 37AG 37AH 37AS - 118 120 120 120 Air handling units Type Standard units Standard energy recovery units Modular units Range Cooling capacity, kW 39SQ 39SQC/R/P 39HQ 39MQ 101 Heating capacity, kW - Air flow, l/s 400-7300 200-8200 1500-35000 Page 122 124 126 128 HYBRID TERMINAL Air treatment 36XB Options Communicating controller t #.4DPNQBUJCMFDPOUSPMMFS t 'PSQJQFQJQFFMFDUSJDIFBUFS and 4 pipe applications t "RVBTNBSU&WPMVUJPO4ZTUFN compatible t 7BSJBCMFGBOTQFFEDPOUSPMEFNBOE based ventilation (CO2 monitoring) and coil condensation control. t *OUFHSBUFEXJOEPXCMJOEBOE lighting control. t .PUPSJTFECMJOETMJHIUJOHDPOUSPM Aquasmart New System Manager Features t 5IF9#)ZCSJE5FSNJOBMDPNCJOFTUIFBEWBOUBHFTPGCPUIDIJMMFECFBNTBOEGBO coils: energy efficiency, high levels of comfort, extremely low noise and high indoor air quality. t 5IFMPXIFJHIUQSPmMFNN PGUIFVOJUGBDJMJUBUFTJOTUBMMBUJPOJOMPXIFJHIU ceilings and allows increased room heights for refurbishment projects. t 6OJUBFTUIFUJDTDBOCFUBJMPSFEUPTVJUTJUFTQFDJmDDFJMJOHMBZPVUTDPMPVSTDIFNFT and return air grill design. t 6OMJLFDPOWFOUJPOBMDIJMMFECFBNTUIF$BSSJFS9#)ZCSJEUFSNJOBMJTmUUFEXJUI a coil condensate drain pan as standard. Even if the cooling coil is supplied with chilled water at 6°C, there is no danger of condensate falling into the occupied space. t "VOJUNPVOUFEDIBOHFPWFSWBMWFBMMPXTUIFDPJMUPCFDPOOFDUFEUPBQJQFXBUFS system so providing either cooling or heating, as required. t *GSFRVJSFEUIF$BSSJFS9#)ZCSJE5FSNJOBMDBOCFmUUFEXJUIBSPPNBJSSFUVSO filter G3 to F5. This filter is accessible for cleaning / replacement without disturbing the unit / ceiling. Principals of Operation t 1SJNBSZWFOUJMBUJPOBJSJTTVQQMJFEUPFBDIVOJUJOEVDJOHTFDPOEBSZSPPN BJSnPX over the cooling / heating coil without the need to run the unit fan. t %VSJOHQFSJPETPGQFBLEFNBOEUIFVOJUGBONBZCFFOFSHJTFEUPJODSFBTFTFDPOEBSZ air flow hence and boosting the unit cooling / heating output. t 6OJRVF$BSSJFSTVQQMZBJSEJòVTFSEFTJHOFOTVSFTFYDFMMFOUBJSEJTUSJCVUJPOOP ‘dumping’ and minimal room temperature gradients in both cooling and heating. t 5IFQSJNBSZWFOUJMBUJPOBJSWPMVNFDBOCFDPOUSPMMFECBTFEPOSPPN$02 levels to maximise comfort and minimise system energy consumption t 5IF$02 sensor (optional) mounted in the secondary (room) air flow can modulate the supply of primary ventilation air to the unit from 2.8 to 33 l/s, depending on room occupancy. t 6TJOHUIFVOJUGBOPOMZXIFOUIFSFJTBQFBLEFNBOEJOUIFPDDVQJFETQBDFPòFST energy savings for up to 80% of the annual building occupancy. t #BTFEPOBUZQJDBMPóDFQSPmMFMPBETUIJTFDPOPNZDBOSFTVMUJOBOBWFSBHF annual unit specific fan power (A-SFP) <0.05 W/l/s t "TTVSFEBJSRVBMJUZJOBEEJUJPOUPWBSZJOHUIFRVBOUJUZPGIZHJFOJDBJSUIFIZCSJE terminal 36XB may receive a filter on the return air available from the grid. t &OFSHZFóDJFODZFBTZJOTUBMMBUJPODPNGPSUMPXOPJTFBOEIJHIJOEPPSBJSRVBMJUZ 102 36XB Cooling capacities Room Temperature: Dry bulb = 27°C and humidity = 47% - Fresh air temperature 14°C m3/h V 30 0 2 Chilled water temperature 7-12°C Total cooling Sensible Coil capacity cooling Water flow capacity W W l/h 269 249 43 537 416 68 5 8 0 2 5 8 0 3 5 8 0 2 5 8 0 2 5 8 891 1297 753 830 1145 1465 1107 1128 1414 1698 1443 1508 1730 1987 1767 1797 1980 2194 Air flow 60 90 120 150 LEC Fan speed 672 977 609 664 895 1136 902 917 1129 1346 1184 1233 1401 1600 1460 1484 1624 1791 130 202 83 97 151 205 122 126 173 223 158 169 205 252 191 194 227 263 Water pressure drop KPa 1 2 Chilled water temperature 14-17°C Total cooling Sensible Coil capacity cooling Water flow capacity W W l/h 256 252 36 330 325 58 Water pressure drop KPa 1 1 Air Fan consumption pressure drop Pa W Noise Pressure level dB(A)* Noise level 0 3.7 9 10 < 20 < 20 < 20 < 20 4 10 2 2 6 10 4 4 7 12 6 7 10 15 9 9 12 71 508 719 504 542 703 870 748 759 906 1055 985 1018 1135 1271 1217 1233 1329 1444 3 7 1 2 4 7 2 3 5 9 4 5 7 11 6 7 9 12 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 11 14 28 29 30 32 57 57 59 61 98 98 99 100 149 149 150 151 32 44 < 20 < 20 32 44 < 20 < 20 32 44 35 35 35 45 41 41 42 46 27 39 < 20 < 20 27 39 < 20 < 20 27 39 30 30 30 40 36 36 37 41 Fan Air consumption pressure drop W Pa Noise Pressure level dB(A)* Noise level 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 0 3.7 5.7 10.6 < 20 < 20 32 44 < 20 < 20 32 44 < 20 < 20 32 44 35 35 35 45 41 41 42 46 < 20 < 20 27 39 < 20 < 20 27 39 < 20 < 20 27 39 30 30 30 40 36 36 37 41 503 714 499 537 697 865 743 754 901 1051 989 1013 1130 1268 1212 1228 1325 1441 108 169 68 79 126 173 101 104 144 187 130 140 173 212 158 162 191 223 NR* Preliminary Data : * Sound Level guidance with acoustic atenuation -9 dB(A) Heating capacities Room Temperature: 20°C - Fresh air temperature 20°C Air flow LEC Fan speed m3/h V 30 0 2 5 8 0 2 5 8 0 3 5 8 0 2 5 8 0 2 5 8 60 90 120 150 Hot water temperature 70-50°C Total heating Coil capacity Water flow W 444 718 1365 2127 873 1009 1593 2195 1275 1316 1849 2383 1654 1777 2195 2684 2013 2070 2416 2829 l/h 18 32 61 94 40 43 68 97 58 61 83 104 72 79 97 119 90 94 104 126 Water pressure drop KPa 1 1 1 2 1 1 1 2 1 1 2 2 1 1 2 3 2 2 3 3 Hot water temperature 45-40°C Total heating Coil capacity Water flow W 241 390 749 1179 475 551 877 1219 699 722 1021 1327 912 981 1219 1500 1115 1148 1346 1583 l/h 43 68 130 205 83 97 151 212 122 126 176 230 158 169 212 259 194 198 234 274 Preliminary Data : * Sound Level guidance with acoustic atenuation -9 dB(A) Duct connection (external) 103 Water pressure drop KPa 1 1 4 9 2 1 5 9 3 4 7 11 6 6 9 13 8 8 11 15 9 10 11 14 28 29 30 32 57 57 59 61 98 98 99 100 149 149 150 151 NR* CASSETTE FAN COIL UNITS Air treatment 42GW Options/accessories Features t t t t t t 4JYTJ[FTXJUIJOUFHSBUFEDPPMJOHBOEIFBUJOHDPJMTUXPQJQFPSUXPQJQFXJUI electric heater, and four-pipe applications. Air flow range 100-400l/s, cooling capacity 1.6-8.7kW, heating capacity 2.2-15.5kW. t 5IF(8@"$JTBWBJMBCMFXJUIBOFXHFOFSBUJPOUISFFTQFFE"$NPUPS5IF (8@-&$JTBWBJMBCMFXJUIBWBSJBCMFTQFFE-PX&OFSHZ$POTVNQUJPO&$NPUPS t %FTJHOFEGPSJOTUBMMBUJPOJOGBMTFDFJMJOHTXJUIBOBMMJOPOFBJSEJTUSJCVUJPOHSJMMF t 3FMJBCMFDPPMJOHBOEIFBUJOHGPSPóDFTTIPQTSFTUBVSBOUTNFFUJOHSPPNT t &MFHBOUBJSJOMFUHSJMMFCMFOETJOXJUIBOZSPPNEÏDPS t -JHIUBOEFBTZUPJOTUBMM5IFTNBMMDIBTTJTmUTOFBUMZXJUITUBOEBSEDFJMJOHUJMFT t 'PVSXBZBJSEJTUSJCVUJPOGPSJOEJWJEVBMDPNGPSUPSMPDBMJTFEDPOUSPM t /FXDFOUSJGVHBMGBOBOEUIFGBONPUPSBTTFNCMZFOTVSFFYUSBRVJFUPQFSBUJPO t 4UBOEBSEmMUFSIBTBQMFBUFETVSGBDFUIBUJTMBSHFSUIBOJOBDPOWFOUJPOBMmMUFS t 4QFDJBMEJòVTFSEFTJHOGPSSBQJECMFOEJOHPGTVQQMZBOESPPNBJS$POEJUJPOFE air is directed along the ceiling. Return air enters the unit through a large grille. t )JHIQFSGPSNBODFDPOEFOTBUFESBJOQVNQGPSGBTUBOERVJFUDPOEFOTBUFSFNPWBM t &BTZNBJOUFOBODFXJUIEJSFDUBDDFTTGSPNCFMPXUPBMMNBJODPNQPOFOUT 5XPPSGPVSXBZWBMWFT 'SFTIBJSJOMFU $POEJUJPOFEBJSUPBEKBDFOUSPPNLJU &MFDUSJDIFBUFS "VYJMJBSZESBJOQBO Standard controls Aquasmart New System Manager Electronic thermostat t 'PVSWFSTJPOT"#$BOE%XJUIQPUFOUJPNFUFS t &$WFSTJPUISFFDPOmHVSBCMFEJTDSFUFTQFFETWJB7TJHOBM t "VUPNBUJDPSNBOVBMUISFFTQFFETFMFDUJPO t "VUPNBUJDPSNBOVBMDIBOHFPWFS t &MFDUSJDIFBUDPOUSPM t $PNGPSUFDPOPNZGSPTUQSPUFDUJPONPEFT HDB controller t %JHJUBMEJTQMBZPSJOGSBSFEUFSNJOBM t 6OJUHSPVQJOHDBQBCJMJUZ t "EKVTUBCMFTFUUJOHTBOEQBSBNFUFST t 5JNFSBOEEBJMZTDIFEVMJOH NTC communicating controller t /FUXPSLDPNNVOJDBUJPO t "RVBTNBSU&WPMVUJPOTZTUFNDPNQBUJCMF t *"2BOE%$7NBOBHFNFOU t .PUPSJTFECMJOETMJHIUJOHDPOUSPM 104 42GW Physical and electrical data, units with AC motors 42GW Coil type Fan speed* Air flow Cooling mode Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drop Heating mode Heating capacity Water pressure drop Water content Sound power level Sound pressure level** Power input Current input Eurovent energy class FCEER/FCCOP Electric heater (high capacity) Current input (high capacity) l/s 200C 2 pipes 1 2 183 125 kW kW l/s l/h kPa 2.40 2.01 0.11 413 11.1 kW kPa l dB(A) dB(A) W A 3.20 10.9 0.55 47 38 58 0.27 D/D 1500 6.3 W A 42GW Coil type Fan speed* Air flow Cooling mode Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drop Water content Heating mode Heating capacity Water flow rate Water pressure drop Water content Sound power level Sound pressure level** Power input Current input Eurovent energy class FCEER/FCCOP * ** 3 100 300C 2 pipes 1 2 204 140 1.80 1.49 0.09 310 6.5 1.55 1.31 0.07 267 4.9 4.00 3.10 0.19 688 11.0 2.50 5.6 2.20 4.0 37 28 35 0.17 32 23 25 0.12 5.00 11.1 1.1 52 43 54 0.24 C/C 2500 10.4 l/s 200D 4 pipes 1 183 kW kW l/s l/h kPa l kW l/s l/h kPa l dB(A) dB(A) W A 2 125 3 100 2.20 2.00 0.11 378 13.7 0.4 1.65 1.48 0.08 284 8.2 1.45 1.27 0.07 249 6.6 1.90 0.05 163 31.4 0.1 47 38 58 0.27 E/E 1.44 0.03 124 21.1 1.24 0.03 107 17.0 37 28 35 0.17 32 23 25 0.12 3 89 400C 2 pipes 1 2 249 173 2.90 2.20 0.14 499 6.2 1.90 1.41 0.09 327 2.9 4.70 3.70 0.22 808 14.7 4.00 5.2 2.50 1.9 44 35 32 0.14 32 23 16 0.07 6.20 16.2 1.1 57 48 94 0.41 D/D 2500 10.4 300D 4 pipes 1 204 3 134 500C 2 pipes 1 2 272 199 3.50 2.70 0.17 602 8.6 2.85 2.10 0.14 490 6.0 6.30 4.80 0.30 1084 23.3 4.60 8.1 3.70 5.0 48 39 55 0.24 42 33 35 0.16 8.11 18.1 1.6 47 38 63 0.30 C/C 3000 12.5 2 140 3 89 3.50 2.70 0.17 602 10.1 1.1 2.70 2.10 0.13 464 6.6 2.00 1.50 0.10 344 4.0 6.37 0.15 548 25.5 0.6 54 45 54 0.24 C/B 5.10 0.12 439 16.1 3.60 0.09 310 7.8 45 36 32 0.14 33 24 16 0.07 400D 4 pipes 1 249 3 147 600C 2 pipes 1 2 321 229 4.50 3.60 0.22 774 13.6 3.40 2.70 0.16 585 8.7 7.20 5.50 0.34 1238 11.6 6.00 10.1 4.50 6.2 40 31 39 0.17 34 25 27 0.12 10.00 10.5 2.4 53 44 85 0.46 C/C 3000 12.5 2 173 3 134 4.10 3.30 0.20 705 13.1 1.1 3.25 2.60 0.16 559 8.9 2.60 2.05 0.12 447 6.2 6.80 0.16 585 29.2 0.6 57 48 94 0.41 D/C 5.80 0.14 499 21.0 5.00 0.12 430 15.4 48 39 55 0.24 42 33 35 0.16 600D 4 pipes 1 321 3 139 701C 2 pipes 1 2 402 299 3 166 5.50 4.10 0.26 946 7.0 3.70 2.70 0.18 636 3.4 8.70 6.40 0.42 1496 19 6.60 4.85 0.32 1135 12 4.05 3.00 0.19 697 5 7.40 6.6 4.60 3.3 9.30 11.15 5.20 4.80 46 37 59 0.27 37 28 33 0.14 11.60 17.96 2.4 59 59 123 0.63 C/C 3000 12.5 52 52 90 0.41 40 40 43 0.19 2 229 3 139 6.70 5.10 0.32 1152 23.2 2.4 5.00 3.80 0.24 860 14.1 3.00 2.20 0.14 516 5.9 11.50 0.27 989 13.6 1.2 53 44 85 0.46 C/B 8.90 0.21 765 8.9 6.00 0.14 516 4.6 46 37 59 0.27 37 28 33 0.14 701D 4 pipes 1 402 2 299 3 166 8.20 6.20 0.39 1410 33 2.4 6.80 5.20 0.32 1170 24 3.80 2.70 0.18 654 9 14.50 0.35 1247 20 1.2 59 50 123 0.63 C/C 11.50 0.27 989 14 7.30 0.17 628 6 52 43 90 0.41 40 31 43 0.19 Based on Eurovent conditions: Cooling mode (2 and 4-pipe coil): entering air temperature 27°C db/1 9°C wb, entering/leaving water temperature 7/12°C, high fan speed. Heating mode (2-pipe coil): entering air temperature 20°C, entering water temperature 50°C, high fan speed, water flow rate as cooling mode. Heating mode (4-pipe coil): entering air temperature 20°C, entering water temperature 70°C, high fan speed, water Δt = 10 K Fan speeds: 1 = high, 2 = medium, 3 = low Sound pressure level and NR values are based on a hypothetical sound attenuation for the room of -9 dB(A). Note: Electrical heater version is available on all 2-pipe units. Physical and electrical data, units with LEC motors Note: All other data is the same as for the units with AC motors 42GW Coil type Voltage (d.c.) Air flow Power input Current input Eurovent energy class FCEER/FCCOP 42GW Coil type Voltage (d.c.) Air flow Power input Current input Eurovent energy class FCEER/FCCOP V l/s W A V l/s W A 209C 2 pipes 10 183 23 0.19 A/A 209D 4 pipes 10 183 23 0.19 B/B 6 125 10 0.10 6 125 10 0.10 2 100 7 0.08 2 100 7 0.08 309C 2 pipes 10 204 33 0.27 A/A 309D 4 pipes 10 204 32 0.29 A/A 6 140 14 0.13 6 140 14 0.14 2 89 7 0.08 2 89 7 0.08 409C 2 pipes 10 249 57 0.46 B/B 409D 4 pipes 10 249 57 0.46 B/A 6 173 23 0.20 6 173 22 0.21 2 134 13 0.12 509C 2 pipes 10 272 25 0.23 A/A 6 199 12 0.12 2 147 7 0.08 609C 2 pipes 10 321 46 0.40 A/A 609D 4 pipes 10 321 46 0.40 A/A 2 134 13 0.12 6 229 23 0.22 6 229 23 0.22 2 139 9 0.10 2 139 9 0.10 709C 2 pipes 10 443 115 0.89 A/A 709D 4 pipes 10 443 115 0.89 A/A 6 299 40 0.35 2 6 299 40 0.35 2 166 11 0.12 166 11 0.12 Dimensions and weights All units Dimensions (H x L x D) Grille dimensions (H x L x D) Weight unit/weight grille mm mm kg 42GW 200/209 298 x 569/627 x 569/627 36 x 720 x 720 14.8/3 42GW 300/309 298 x 569/627 x 569/627 36 x 720 x 720 16.5/3 42GW 400/409 298 x 569/627 x 569/627 36 x 720 x 720 16.5/3 Where two values are given the second value applies to units with two or four-way valves. 105 42GW 500/509 302 x 822/879 x 822/879 37 x 960 x 960 37/5 42GW 600/609 302 x 822/879 x 822/879 37 x 960 x 960 39.6/5 42GW 700/709 302 x 822/879 x 822/879 37 x 960 x 960 39.6/5 ROOM FAN COIL UNITS Air treatment 42N Accessories Features t t t t t t t &MFWFOTJ[FTXJUIUXPQJQFUXPQJQFDIBOHFPWFSPSGPVSQJQFDPJMBJSnPXSBOHF 35-422 l/s, cooling capacity range 0.8-6.4 kW, heating capacity range 1.1-9.5 kW. t 5IF/@4JTBWBJMBCMFXJUIBOFXHFOFSBUJPOUISFFPSmWFTQFFE"$NPUPS 5IF/@&JTBWBJMBCMFXJUIBWBSJBCMFTQFFEMPXFOFSHZDPOTVNQUJPO&$NPUPS t $PODFBMFEPSDBCJOFUDIJMMFEXBUFSGBODPJMTZTUFNEFTJHOFEGPSWFSUJDBMBOE horizontal installation in a room or above a false ceiling. t &DPOPNJDBMDPPMJOHBOEIFBUJOHGPSIPUFMTDPNNFSDJBMBOESFTJEFOUJBMBQQMJDBUJPOT t $BCJOFUWFSTJPODPNQMFUFXJUIDPOUSPMUFSNJOBM t $PNCJOFTBFTUIFUJDTMJNMJOFEFTJHOXJUIIJHIJOTUBMMBUJPOnFYJCJMJUZ t 5XPGBOUZQFTBUBOHFOUJBMGBOGPSVMUSBMPXOPJTFMFWFMBOEBDFOUSJGVHBMGBO for high air distribution system compatibility. t 'BDUPSZNPVOUFE15$FMFDUSJDIFBUFSXJUIMPXBOEIJHIDBQBDJUZTFUUJOHT t -PXIZESBVMJDQSFTTVSFESPQXJUIBWBMWFNPVOUFE t 2VJDLJOTUBMMBUJPOXJUIGBDUPSZNPVOUFEPQUJPOTDPOUSPMTWBMWFT t -&$NPEFMTFOIBODFVOJUQFSGPSNBODFPòFSJOHSFEVDFEFOFSHZDPTUT improved comfort, maximum flexibility and extended operating life. t t t t t t t t t t 4VQQPSUJOHGFFU 4VQQPSUJOHGFFUBOEDPWFSQBOFM 3FUVSOBJSHSJMMFGPSDBCJOFUVOJU 3FBSDMPTJOHQBOFM $BCJOFUPODPODFBMFEVOJUT %JTDIBSHFBJSTMFFWFDPODFBMFEVOJUT only) 4VQQPSUJOHCSBDLFUT "BOE#UZQFUIFSNPTUBUT 4QFDJBMJOTUBMMBUJPOLJU $PMEESBVHIUQSFWFOUJPOLJUBMM two-pipe sizes "VUPNBUJDDIBOHFPWFSTXJUDI "JSTFOTPSXJUINDBCMF 8BUFSTFOTPSLJUXJUINDBCMF *OGSBSFESFNPUFDPOUSPMMFSBOE infrared remote receiver kit ;6*PS;6*JOUFSGBDF 46*PS46*XJUIXJUIPVUGBO speed selection) Standard controls Aquasmart New System Manager Electronic thermostat t 'PVSWFSTJPOT"#$BOE%XJUIQPUFOUJPNFUFS t &$WFSTJPUISFFDPOmHVSBCMFEJTDSFUFTQFFETWJB7TJHOBM t "VUPNBUJDPSNBOVBMUISFFTQFFETFMFDUJPO t "VUPNBUJDPSNBOVBMDIBOHFPWFS t &MFDUSJDIFBUDPOUSPM t $PNGPSUFDPOPNZGSPTUQSPUFDUJPONPEFT HDB controller t %JHJUBMEJTQMBZPSJOGSBSFEUFSNJOBM t 6OJUHSPVQJOHDBQBCJMJUZ t "EKVTUBCMFTFUUJOHTBOEQBSBNFUFST t 5JNFSBOEEBJMZTDIFEVMJOH NTC communicating controller t /FUXPSLDPNNVOJDBUJPO t "RVBTNBSU&WPMVUJPOTZTUFNDPNQBUJCMF t *"2BOE%$7NBOBHFNFOU t .PUPSJTFECMJOETMJHIUJOHDPOUSPM 106 42N Physical and electrical data, units with AC motors 42N_S, 2-pipe coil Fan speed Fan type Air flow Cooling mode* Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drop Heating mode** Heating capacity Water pressure drop Sound power/sound pressure*** Electrical data Power input Current drawn Electric heater (high/low capacity) l/s-m3/h 15 5 4 One, tangential 35-125 56-200 kW kW l/s-l/h kPa 0.83 0.7 0.04-143 6.2 1.07 0.93 0.05-184 9.6 1.19 1.03 0.06-205 11.5 1.34 1.19 0.06-230 14.1 1.49 1.31 0.07-256 16.9 1.27 0.97 0.07-239 2.8 1.81 1.42 0.09-311 4.2 1.9 1.5 0.10-358 5.3 2.34 1.85 0.11-402 6.4 2.32 1.9 0.12-437 7.3 2.1 1.65 0.10-361 5.4 3 2.35 0.14-516 9.5 3.6 2.9 0.17-619 12.7 kW kPa dB(A) 1.14 4.9 28/19 1.42 7.8 37/28 1.66 9.4 42/33 1.89 11.6 47/38 2.09 14 51/42 1.7 2.2 29/20 2.1 3.4 38/29 2.54 4.3 42/33 2.87 5.2 46/37 3.18 6 50/41 2.56 4.4 44/35 3.68 7.8 54/45 4.38 10.6 61/52 W 16 17 30 55 A 0.08 0.08 800/500 W, 3.48/2.18 A 2 1 69-250 84-300 97-350 20 5 4 One, centrifugal 59-215 80-285 19 23 30 29 0.09 0.11 0.13 0.13 0.13 1000/500 W, 4.35/2.18 A D/D Eurovent energy class FCEER/FCCOP 42N_S, 2-pipe coil Fan speed Fan type Air flow Cooling mode* Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drop Heating mode** Heating capacity Water pressure drop Water content Sound power/sound pressure*** Electrical data Power input Current drawn Electric heater (high/low capacity) Eurovent energy class FCEER/FCCOP 3 3 2 1 92-330 107-385 128-460 26 3 2 One, centrifugal 93-335 149-536 l/s-m3/h 153-550 182-655 kW kW l/s-l/h kPa 2.07 1.4 0.10-356 6 2.54 1.96 0.12-437 8.6 3.01 2.35 0.14-518 11.5 kW kPa l dB(A) 2.86 4.8 1.8 36/27 3.54 6.9 1.8 42/33 4.18 9.2 1.8 47/38 W A 42 44 46 0.19 0.2 0.21 2000/1000 W, 8.70/4.35 A D/D 3 31 34 36 45 0.15 0.16 0.21 0.25 1000/500 W, 4.35/2.18 A 207-745 3.46 2.84 0.17-595 14.6 3.7 3.1 0.18-636 16.4 3 2.35 0.14-516 11.4 4.8 11.7 1.8 51/42 5.29 13.1 1.8 54/45 4.05 9.2 1.8 47/38 50 0.23 57 0.25 45 75 100 0.21 0.35 0.45 2000/1000 W, 8.70/4.35 A D/D 1 65 0.3 E/E 42 3 2 Two, centrifugal 147-531 222-798 2 196-706 0.14 E/E 30 5 4 Two, centrifugal 97-350 126-455 1 3 2 268-965 45 5 4 Two, centrifugal 146-525 185-665 224-805 277-995 65 3 2 1 Two, centrifugal 333-1195 237-853 331-1191 422-1519 4 3.3 0.19-688 18.8 4.5 3.85 0.22-774 23 2.6 2.12 0.12-447 3.2 3.37 2.78 0.16-580 5 3.98 3.3 0.19-695 6.7 4.74 3.98 0.23-815 9 5.45 4.55 0.26-937 11.5 3.9 3.2 0.19-671 6.4 5.45 4.6 0.26-937 11.5 6.35 5.1 0.30-1092 15 5.55 15 1.8 57/48 6.4 18.4 1.8 62/53 4 2.7 2.1 41/32 5.05 4.2 2.1 47/38 5.9 5.5 2.1 53/44 6.9 7.5 2.1 57/48 8.08 9.5 2.1 62/53 6.1 5.4 2.1 54/45 8 9.5 2.1 62/53 9.5 12.3 2.1 68/59 92 0.41 128 0.55 90 125 165 0.41 0.55 0.72 2000/1000 W, 8.70/4.35 A E/E 1 69 77 83 0.31 0.34 0.37 2000/1000 W, 8.70/4.35 A E/E 1 Physical and electrical data, units with LEC motors 42N_E, 2-pipe coil Fan speed Fan type Air flow Cooling mode* Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drop Heating mode** Heating capacity Water pressure drop Sound power/sound pressure*** Electrical data Power input Current drawn Electric heater (high/low capacity) Eurovent energy class FCEER/FCCOP * ** *** 60 80 100 l/s m3/h 19 20 40 One, tangential 35 56 125 200 69 250 84 300 kW kW l/s l/h kPa 0.83 0.7 0.04 143 6.2 1.07 0.93 0.05 184 9.6 1.19 1.03 0.06 205 11.5 kW kPa dB(A) 1.14 4.9 28/19 1.42 7.8 37/28 1.66 9.4 42/33 W 3 4 7 A 0.08 0.09 0.1 800/500 W, 3.48/2.18 A % 80 100 97 350 29 20 40 60 One, centrifugal 59 80 92 215 285 330 107 385 1.34 1.19 0.06 230 14.1 1.49 1.31 0.07 256 16.9 1.29 0.91 0.07 239 2.8 1.81 1.42 0.09 311 4.2 1.93 1.41 0.1 358 5.3 1.89 11.6 47/38 2.09 14 51/42 1.57 2.2 29/20 2.1 3.4 38/29 2.35 4.3 42/33 5 7 10 14 3 0.11 0.15 0.09 0.09 0.11 100/500 W, 4.35/2.18 A A/A A/A 80 100 128 460 39 20 40 60 Two, centrifugal 97 126 153 350 455 550 80 100 207 745 49 20 40 60 Two, centrifugal 146 185 224 525 665 805 182 655 277 995 333 1195 2.34 1.85 0.11 402 6.4 2.36 1.79 0.12 437 7.3 2.07 1.4 0.1 356 6 2.54 1.96 0.12 437 8.6 3.01 2.35 0.14 518 11.5 3.46 2.84 0.17 595 14.6 3.7 3.1 0.18 636 16.4 2.6 2.12 0.12 447 3.2 3.37 2.78 0.16 580 5 3.98 3.3 0.19 685 6.7 4.74 3.98 0.23 815 9 5.45 4.55 0.26 937 11.5 2.87 5.2 46/37 2.94 6 50/41 2.86 4.8 36/27 3.54 6.9 42/33 4.18 9.2 47/38 4.8 11.7 51/42 5.29 13.1 54/45 4 2.7 41/32 5.05 4.2 47/38 5.9 5.5 53/44 6.9 7.5 57/48 8.08 9.5 62/53 9 15 23 35 8 14 25 39 0.29 0.1 0.15 0.22 0.35 2000/1000 W, 8.70/4.35 A 10 15 5 0.13 0.16 0.1 0.12 0.16 0.21 2000/1000 W, 8.70/4.35 A A/A 65 0.52 A/A Eurovent conditions: Entering air temperature = 27°C db/19°C wb – entering/leaving water temperature = 7°C/12°C, high fan speed. Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 50°C, same water flow rate as in cooling mode. Based on a hypothetical acoustic attenuation for the room and the air distribution system of -9 dB(A). Note: For data on 4-pipe coils please refer to the specific product documentation. Dimensions and weights Length Width Height Weight mm mm mm kg Vertical units with cabinet S15 S20-26 S30-42 E19 E29 E39 830 1030 1230 220 220 220 657 657 657 17 19 22 S45-65 E49 1430 220 657 35 Horizontal units with cabinet S15 S20-26 S30-42 E19 E29 E39 830 1030 1230 657 657 657 220 220 220 17 19 22 S45-65 E49 1430 657 220 35 107 Horizontal concealed units S15 S20-26 S30-42 E19 E29 E39 606 806 1006 518 518 518 220 220 220 13 15 16 S45-65 E49 1206 518 220 28 Vertical concealed units S15 S20-26 S30-42 E19 E29 E39 606 806 1006 220 220 220 640 640 640 13 15 16 S45-65 E49 1206 220 640 28 DUCTED FAN COIL UNITS Air treatment 42EM Options/accessories Features t 8BMMNPVOUFEJOGSBSFESFDFJWFS t 'BDUPSZNPVOUFEUXPPSGPVSXBZ valves t %JòFSFOUTJ[FTXJUIUXPQJQFUXPQJQFQMVTFMFDUSJDIFBUFSPSGPVSQJQFDPJMT with an air flow range from 66 to 237l/s, a cooling capacity range from 0.7 to 6.8kW and a heating capacity range from of 1.1 to 7.8kW. t %FDFOUSBMJTFEDPNQBDUEVDUFEDIJMMFEXBUFSGBODPJMTZTUFNEFTJHOFEGPS installation in plant rooms. This allows centralised service and maintenance. t 3FMJBCMFBOEFDPOPNJDBMDPPMJOHBOEIFBUJOHGPSMJHIUDPNNFSDJBMBOEPóDF applications. t -PXIFJHIUPGNN t *OTUBMMBUJPOnFYJCJMJUZXJUIUXPWFSTJPOTNPEVMBSPSDPNQBDU t $PNQBUJCMFXJUIUIF#%BJSEJòVTFSSBOHF t "JSPVUMFUNPEVMBSJUZXJUIEJòFSFOUTQJHPUT t &YUSFNFMZMPXTPVOEMFWFMJOUIFEVDUJOHPGUIFBJSEJTUSJCVUJPOTZTUFN t 4JYTQFFEGBONPUPSPòFSJOHBDIPJDFPGTFWFSBMNFEJVNDPNGPSUTQFFET t "WBJMBCMFXJUIMPXDPOTVNQUJPOWBSJBCMFTQFFE&$NPUPS-&$ t )JHIQSFTTVSFDFOUSJGVHBMGBOTDPNQBUJCMFXJUIBMMNBJOBJSEJTUSJCVUJPOTZTUFNT t )JHIFóDJFODZ&6mMUFSBTTUBOEBSE t 4BGFGBDUPSZJOTUBMMFEFMFDUSJDIFBUFSGPSTJOHMFPSUXPTUBHFIPUXBUFSIFBUJOH t -PXXBUFSQSFTTVSFESPQXJUIBWBMWFNPVOUFEDPNQBUJCMFXJUIBMMDIJMMFS pump kits. t 2VJDLJOTUBMMBUJPOXJUIGBDUPSZJOTUBMMFEPQUJPOTDPOUSPMTWBMWFT t "UNPTQIFSBTJ[FBOEJTFRVJQQFEXJUIUIFWBSJBCMFTQFFEMPX consumption LEC fan motor assembly, that is controlled by a 0 to 10 V signal, available with the Carrier NTC type electronic control. Standard controls Electronic thermostat t WFSTJPOT"#XJUIQPUFOUJPNFUFS t "VUPNBUJDPSNBOVBMUISFFTQFFE selection t "VUPNBUJDPSNBOVBMDIBOHFPWFS t &MFDUSJDIFBUDPOUSPM t $PNGPSUFDPOPNZGSPTUQSPUFDUJPO modes HDB controller t %JHJUBMEJTQMBZPSJOGSBSFEUFSNJOBM t 6OJUHSPVQJOHDBQBCJMJUZ t "EKVTUBCMFTFUUJOHTBOEQBSBNFUFST t 5JNFSBOEEBJMZTDIFEVMJOH NTC communicating controller t /FUXPSLDPNNVOJDBUJPO t "RVBTNBSU&WPMVUJPODPNQBUJCMF t *"2BOE%$7NBOBHFNFOU t .PUPSJTFECMJOETMJHIUJOHDPOUSPM 35BD linear diffuser (supply and return air) Aquasmart New System Manager 108 42EM Physical data 42EM Fan speed Air flow l/s m3/h Available static pressure Pa 05 L M H 09 L M H 10 L M H 19 L M H 22 L M H 29 L M H 32 L M H 39 L M H 58 210 23 86 309 50 90 324 58 35 125 1 110 395 50 133 480 75 74 266 19 119 427 50 132 475 62 34 124 1 127 456 50 151 545 75 85 306 12 173 623 50 199 716 66 55 198 3 211 760 50 237 853 63 85 306 12 173 623 50 199 716 66 55 198 3 211 760 50 237 853 63 2.18 1.61 0.10 374 24 0.35 2.27 1.68 0.11 389 25 0.35 0.99 0.7 0.05 169 5 0.35 2.65 1.99 0.13 457 32 0.35 3.07 2.34 0.15 526 42 0.35 1.88 1.39 0.09 321 11 0.5 2.76 2.11 0.13 475 23 0.5 3 2.31 0.14 516 27 0.5 0.89 0.64 0.05 162 3 0.5 2.75 2.09 0.14 499 25 0.5 3.14 2.43 0.16 569 33 0.5 2.32 1.7 0.11 399 9 1 4.23 3.21 0.20 726 30 1 4.7 3.61 0.22 808 36 1 1.56 1.13 0.07 269 4 1 4.92 3.8 0.23 845 39 1 5.36 4.18 0.26 921 45 1 2.84 1.92 0.13 484 9 1.7 5.34 3.76 0.26 918 32 1.7 6.02 4.23 0.29 1034 41 1.7 1.71 1.23 0.09 313 4 1.7 6.18 4.34 0.30 1062 42 1.7 6.8 4.81 0.32 1166 49 1.7 Cooling mode, two pipes* Total cooling capacity Sensible cooling capacity kW Water flow rate l/h Water pressure drop kPa Water content l 1.57 1.14 0.08 270 13 0.35 kW 1.91 2.69 2.8 1.18 3.3 3.88 2.44 3.74 4.1 1 3.36 3.91 2.87 5.44 6.13 1.9 6.43 7.08 3.05 5.94 6.72 1.99 7.07 7.82 Total cooling capacity Sensible cooling capacity kW Water flow rate l/s Water pressure drop kPa Water content l 1.43 1.08 0.07 247 9 0.32 1.98 1.52 0.10 342 17 0.32 2.06 1.58 0.10 355 19 0.32 0.9 0.66 0.04 157 4 0.32 2.41 1.87 0.12 415 16 0.32 2.78 2.19 0.13 478 22 0.32 1.78 1.34 0.09 310 14 0.45 2.55 1.99 0.12 446 28 0.45 2.75 2.16 0.13 482 33 0.45 0.92 0.67 0.04 155 4 0.45 2.67 2.1 0.13 457 31 0.45 3.01 2.4 0.14 518 39 0.45 2.23 1.65 0.11 382 10 0.8 3.96 3.06 0.19 679 29 0.8 4.38 3.43 0.21 753 35 0.8 1.51 1.1 0.07 260 4 0.8 4.57 3.59 0.22 785 44 0.8 4.95 3.94 0.24 850 43 0.8 2.75 1.89 0.13 472 12 1.5 5.18 3.65 0.25 890 42 1.5 5.83 4.14 0.28 1002 53 1.5 1.78 1.23 0.09 306 5 1.5 5.99 4.26 0.29 1030 53 1.5 6.57 4.7 0.31 1127 54 1.5 1.47 0.04 129 10 0.11 D/D D/D 2 0.05 175 17 0.11 2.08 0.05 182 19 0.11 0.9 0.02 83 3 0.11 B/B A/B 2.41 0.06 212 25 0.11 2.78 0.07 243 32 0.11 2.43 0.06 209 7 0.15 C/D C/C 3.46 0.08 298 14 0.15 3.72 0.09 320 16 0.15 1.01 0.03 110 2 0.15 B/B A/B 2.85 0.09 311 16 0.15 3.22 0.10 352 20 0.15 2.29 0.06 201 3 0.2 D/D C/D 3.98 0.10 349 9 0.2 4.39 0.11 386 10 0.2 1.57 0.04 138 2 0.2 A/A A/A 4.57 0.11 402 11 0.2 4.95 0.12 435 13 0.2 2.29 0.06 201 3 0.2 C/C C/D 3.98 0.10 349 9 0.2 4.39 0.11 386 10 0.2 1.47 0.04 130 1 0.2 A/A A/A 4.09 0.10 360 9 0.2 4.4 0.11 389 11 0.2 kW l/s Heating mode, two pipes** Heating capacity Cooling mode, four pipes* kW l/h Heating mode, four pipes*** kW Heating capacity Water flow rate l/h Water pressure drop kPa Water content l l/s Eurovent energy class FCEER† Eurovent energy class FCCOP† 230 V ± 15 % - 1 ph - 50 Hz Electric heater Maximum capacity Current drawn Sound levels Sound power level (return and radiated) Sound power level (supply) W A 1000 4.35 dB(A) 43 54 57 33 55 56 41 51 53 34 53 58 39 54 57 43 53 55 39 54 57 43 53 55 dB(A) 42 1000 4.35 1000 4.35 2000 8.7 2000 8.7 2000 8.7 2000 8.7 49 50 29 50 55 38 49 51 32 51 56 37 52 55 43 51 53 37 52 55 43 51 53 45 76 44 78 0.17 0.35 230 x 570 110 0.48 6 52 83 62 112 0.29 0.52 230 x 990 128 0.62 4 68 92 128 0.62 4 73 96 1 ph - 50 Hz - 230 V ± 15 % Electrical data, motor Power input W Current drawn A Air filter (G3) mm Technical data Height x depth x length Unit weight 1000 4.35 mm kg 45 77 0.2 0.34 230 x 420 102 0.45 4 230 x 990 62 112 0.29 0.52 230 x 990 Connection diameter, cold and hot-water coils: 1/2” gas (unit nut female), spigot connection diameter 200 mm 250 x 700 x 870 250 x 700 x 870 250 x 850 x 870 250 x 850 x 870 250 x 1270 x 870 250 x 1270 x 870 250 x 1270 x 870 250 x 1270 x 870 17 39 43 41 230 x 420 22 22 230 x 570 22 41 Fan speed: L = Low, M = Medium, H = High * ** *** † Eurovent conditions: Entering air temperature = 27°C db/47% rh – entering water temperature = 7°C, water temperature difference = 5 K. Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 50°C, same water flow rate as in cooling. Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 70°C, water temperature difference = 10 K. The first value is for two-pipe coils and the second value is for four-pipe coils. La première valeur correspond aux batteries à 2 tubes et la seconde valeur aux batteries à 4 tubes. NOTE: Models 2x include sizes 21, 22, 23 and 29 with different speed arrangements. Models 3x include sizes 31, 32, 33 and 39 with different speed arrangements. 109 230 x 990 LARGE DUCTED FAN COIL UNITS Air treatment 42DW Options/accessories Features t 'BDUPSZJOTUBMMFEUXPPSGPVSXBZ valves t )JHIFóDJFODZmMUFS t 'PVSTJ[FTXJUIUXPQJQFUXPQJQFQMVTFMFDUSJDIFBUFSPSGPVSQJQFDPJMTBJSnPX range 220-726 l/s, cooling capacity 4.4-11.7 kW, heating capacity 6.5-19.8 kW. t $PNQBDUEVDUFEDIJMMFEXBUFSGBODPJMVOJUTGPSJOTUBMMBUJPOBCPWFGBMTFDFJMJOHT t 3FMJBCMFFóDJFOUIFBUJOHBOEDPPMJOHGPSDPNNFSDJBMBOESFTJEFOUJBMBQQMJDBUJPOT t .JOJNJTFETJ[FVTJOHB7TIBQFEDPJMBOESFEVDFEIFJHIUPGNN t "JSSFUVSOGSPNUIFSFBSPSCFMPXGPSJODSFBTFEJOTUBMMBUJPOnFYJCJMJUZ t "JSPVUMFUNPEVMBSJUZTMFFWFPSTQJHPUT PVUMFUTPOUIFGSPOUPSBUUIFTJEFT t )JHIDBQBDJUZVOJUXJUIMPXTPVOEMFWFMT t 'PVSTQFFENPUPSPòFSJOHBDIPJDFPGUXPNFEJVNDPNGPSUTQFFET t )JHIQSFTTVSFDFOUSJGVHBMGBOT t $PNQBUJCMFXJUIUIF#%BJSEJòVTFSSBOHF t 4BGFGBDUPSZJOTUBMMFEFMFDUSJDIFBUFSGPSTJOHMFPSUXPTUBHFIPUXBUFSIFBUJOH t -PXIZESBVMJDQSFTTVSFESPQXJUIBWBMWFNPVOUFEDPNQBUJCMFXJUIBMMDIJMMFS pump kits. t 2VJDLJOTUBMMBUJPOXJUIGBDUPSZJOTUBMMFEPQUJPOTDPOUSPMTWBMWFT t *NQSPWFENBSLFUDPNQFUJUJWFOFTT 35BD linear diffuser (supply and return air) Standard controls Aquasmart New System Manager Electronic thermostat t 5XPWFSTJPOT"BOE#XJUIQPUFOUJPNFUFS t &$WFSTJPUISFFDPOmHVSBCMFEJTDSFUFTQFFETWJB7TJHOBM t "VUPNBUJDPSNBOVBMUISFFTQFFETFMFDUJPO t "VUPNBUJDPSNBOVBMDIBOHFPWFS t &MFDUSJDIFBUDPOUSPM t $PNGPSUFDPOPNZGSPTUQSPUFDUJPONPEFT HDB controller t %JHJUBMEJTQMBZPSJOGSBSFEUFSNJOBM t 6OJUHSPVQJOHDBQBCJMJUZ t "EKVTUBCMFTFUUJOHTBOEQBSBNFUFST t 5JNFSBOEEBJMZTDIFEVMJOH NTC communicating controller t /FUXPSLDPNNVOJDBUJPO t "RVBTNBSU&WPMVUJPOTZTUFNDPNQBUJCMF t *"2BOE%$7NBOBHFNFOU t .PUPSJTFECMJOETMJHIUJOHDPOUSPM 110 42DW Physical data Unit size Fan speed Fan Air flow Static pressure Cooling mode Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drop Heating mode, 2 pipes Heating capacity Water pressure drop Heating mode, 4 pipes Heating capacity Water flow rate Water pressure drop Electric heater capacity Sound levels Sound power level Sound pressure level* NR value Power supply Power input Current draw Dimensions Coil outlet/inlet diameter Length Height Depth Weight (without/with electric heater) Unit size Fan speed Fan Air flow Static pressure Cooling mode Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drop Heating mode, 2 pipes Heating capacity Water pressure drop Heating mode, 4 pipes Heating capacity Water flow rate Water pressure drop Electric heater capacity Sound levels Sound power level Sound pressure level* NR value Power supply Power input Current draw Dimensions Coil outlet/inlet diameter Length Height Depth Weight (without/with electric heater) 42DWC 07 Low Medium High Super high 42DWC 09 Low Medium High Super high 42DWC 12 Low Medium High Super high l/s m3/h Pa 228 820 33 250 900 50 260 935 55 273 983 59 253 910 35 303 1090 50 349 1255 65 372 1338 75 478 1720 35 563 2025 50 632 2275 60 668 2403 70 kW kW l/s l/h kPa 5.08 4 0.24 849 16 5.5 4.33 0.26 947 21 5.67 4.47 0.27 980 23 5.88 4.66 0.28 1010 25 5.88 4.54 0.28 1012 16 6.81 5.32 0.33 1173 22 7.69 6.05 0.37 1320 27 8.05 6.37 0.38 1385 30 9.29 7.03 0.55 1992 38 10.4 7.95 0.49 1776 45 11.2 8.66 0.53 1897 54 11.6 9.68 0.54 1950 60 kW kPa 6.74 16 7.28 21 7.60 23 7.78 25 7.95 16 9.31 22 10.10 27 11.02 30 12.21 38 13.79 45 15.19 55 16.58 60 kW l/h l/h kPa W 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 dBA dBA 57 40 37 58 41 38 59 42 39 64 47 44 65 48 45 68 51 48 70 53 50 143 0.62 150 0.65 170 0.74 200 0.87 225 0.98 62 45 41 230-1-50 265 1.15 66 49 45 130 0.57 56 39 35 230-1-50 125 0.54 60 43 40 V-ph-Hz W A 55 38 35 230-1-50 117 0.51 310 1.35 360 1.57 380 1.65 inch mm mm mm kg 3/4 925 285 750 35/39 3/4 925 285 750 37/41 3/4 1325 285 750 48/53 42DWC 16 Low Medium High Super high 42DWD 09 Low Medium High Super high 42DWD 16 Low Medium High Super high l/s m3/h Pa 600 2160 40 656 2360 50 692 2490 55 726 2614 61 253 910 35 303 1090 50 349 1255 65 372 1338 75 600 2160 40 656 2360 50 692 2490 55 726 2614 61 kW kW l/s l/h kPa 12.00 9.39 0.59 2135 48.3 12.70 10.00 0.64 2305 56.1 13.40 10.70 0.64 2309 54.3 13.71 10.53 0.67 2425 58.4 5.56 4.25 0.27 955 21 6.39 4.95 0.30 1097 25 7.06 5.51 0.34 1210 30 7.32 5.82 0.35 1259 33 10.60 8.68 0.51 1831 43 11.30 9.35 0.54 1929 48 11.70 9.74 0.55 1966 50 11.66 9.68 0.56 2004 52 kW kPa 16.7 45 17.9 56.1 18.9 54.2 19.76 58.4 - - - - - - - - kW l/h l/h kPa W 3000 3000 3000 3000 7.02 0.17 604 13 - 7.70 0.19 677 12 - 8.35 0.20 732 17 - 8.83 0.22 777 18 - 14.30 0.36 1278 53 - 15.30 0.38 1353 60 - 15.90 0.39 1395 63 - 15.93 0.39 1400 65 - dBA dBA 70 53 49 72 55 51 73 56 52 64 47 44 65 48 45 72 55 51 73 56 52 430 1.87 450 1.96 175 0.76 197.5 0.86 220 0.96 68 51 48 230-1-50 400 1.74 70 53 49 410 1.78 56 39 35 230-1-50 135 0.59 60 43 40 V-ph-Hz W A 68 51 48 230-1-50 370 1.61 460 2 485 2.11 510 2.22 inch mm mm mm kg 3/4 1325 285 750 53/58 3/4 925 285 750 37 Based on Eurovent rating standards: Cooling: Entering/leaving air temperature = 27°C db/19°C wb – entering/leaving water temperature = 7°C/12°C. Heating (2 pipes): Entering air temperature = 20°C– entering water temperature = 50°C, same water flow rate as in cooling. Heating (4 pipes): Entering air temperature = 20°C – entering/leaving water temperature = 70°C/60°C. * Based on a hypothetical sound attenuation for the room and the system of -17 dB(A). 111 3/4 1325 285 750 53 INDIVIDUAL COMFORT MODULES Air treatment 42BJ Options/accessories Features t 'BDUPSZJOTUBMMFEUXPPSGPVSXBZ valves t )JHIFóDJFODZmMUFS t $POEFOTBUFQVNQ t 5ISFFTJ[FTXJUIUXPQJQFUXPQJQFQMVTFMFDUSJDIFBUFSPSQJQFDPJMTXJUIBO air flow range from 16 to 200l/s, a cooling capacity range from 0.5 to 4.9kW and a heating capacity range from 0.5 to 5.8kW. t $PNQBDU6TIBQFEEVDUFEDIJMMFEXBUFSGBODPJMTZTUFNTEFTJHOFEGPS installation above false ceilings in corridors. t 3FMJBCMFBOEFDPOPNJDBMDPPMJOHBOEIFBUJOHGPSMJHIUDPNNFSDJBMBOEPóDF applications. t *ODMVEFTBDFOUSJGVHBMGBOXJUIBMPXFOFSHZDPOTVNQUJPO-&$ NPUPS5IJT direct-drive motor is electronically commutated (EC motor). It is piloted by a 0-10 V signal that permits operation with a wide range of rotational speeds, varying from the base setting and is precise, simple and quiet. It also includes an air filter, a fresh air inlet with adjustable air quantity, a chilled-water cooling coil and a hot-water heating coil and/or an electric resistance heater. t 6TIBQFNPEFMXJUIJOMFUBOEPVUMFUPOUIFTBNFTJEF t $PNQBUJCMFXJUIUIF#%BJSEJòVTFSSBOHF t -PXIFJHIUPGNNTJ[FTBOE t &YUSBMPXTPVOEMFWFMJOEVDUFEBJSEJTUSJCVUJPOTZTUFN t )JHIQSFTTVSFDFOUSJGVHBMGBOTDPNQBUJCMFXJUIBJSEJTUSJCVUJPOTZTUFNTVQUP 300 Pa. t )JHIFóDJFODZ'PS'mMUFS t 4BGFGBDUPSZJOTUBMMFEFMFDUSJDIFBUFSGPSTJOHMFPSUXPTUBHFIPUXBUFSIFBUJOH t -PXIZESBVMJDQSFTTVSFESPQXJUIBWBMWFNPVOUFEDPNQBUJCMFXJUIBMMDIJMMFS pump kits. t 2VJDLJOTUBMMBUJPOXJUIGBDUPSZJOTUBMMFEPQUJPOTDPOUSPMTWBMWFT t "WBJMBCMFXJUIEFNBOEDPOUSPMWFOUJMBUJPO%$7 BOE$02 sensor. t *NQSPWFENBSLFUDPNQFUJUJWFOFTT Standard controls NTC communicating controller t /FUXPSLDPNNVOJDBUJPO t "RVBTNBSU&WPMVUJPOTZTUFN compatible t *"2BOE%$7NBOBHFNFOU t .PUPSJTFECMJOETBOEMJHIUJOH control Aquasmart New System Manager 35BD linear diffuser (supply and return air) 112 42BJ ICM Physical and electrical data 42BJ ICM LEC Fan speed* Air flow Available static pressure Cooling mode** Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drop Water content Two-pipe heating mode*** Heating capacity Eurovent energy class FCEER/FCCOP Four-pipe heating mode**** Heating capacity Water flow rate l/s m3/h Pa 1.9 L 16 56 1 M 145 521 50 H 201 722 97 2.9 L 24 88 1 M 160 575 50 H 223 803 99 4.9 L 28 101 3 M 148 534 50 H 204 733 92 kW kW l/s l/h kPa l 0.45 0.36 0.02 80 2 0.9 2.99 2.34 0.12 448 27 0.9 3.74 3.00 0.17 628 47 0.9 0.66 0.46 0.03 118 2 1.2 3.95 2.91 0.19 699 39 1.2 5.26 3.95 0.25 912 61 1.2 1.12 0.75 0.06 224 5 1.5 3.94 2.78 0.25 884 61 1.5 4.91 3.53 0.26 935 68 1.5 kW 0.51 C/C 3.56 4.45 0.75 B/B 4.72 6.33 1.19 B/B 4.53 5.77 kW l/s l/h kPa l 0.62 0.02 60 1 0.2 C/C 230-1-50 0.5 11 3.12 0.07 267 15 0.2 3.70 0.10 348 23 0.2 1.08 0.03 94 4 0.29 B/B 4.30 0.10 376 32 0.29 5.18 0.12 449 41 0.29 1.87 0.05 168 8 0.45 B/A 5.47 0.15 550 67 0.45 6.54 0.16 577 73 0.45 2.25 11 1 11 2.25 11 2.25 11 59 69 69 48 43 32 31 34 13 - 56 65 65 44 39 61 72 72 51 46 174 5 315 x 550 46 186 Water pressure drop Water content Eurovent energy class FCEER/FCCOP V-ph-Hz Electric heater Maximum capacity kW 1.9 2.23 0.75 2.12 Maximum current drawn A 11 11 11 11 Sound levels Sound power level (return + radiated) dB(A) 29 53 59 34 52 Sound power level (supply) dB(A) 26 59 66 20 63 Global sound power level dB(A) 31 61 67 34 63 Sound pressure level† dB(A) 10 40 46 13 42 NR value† 35 41 37 230 V-1 ph-50 Hz, EC motor with low energy consumption Electrical data, motor Power input W 4 49 160 4 68 mm 240 x 400 240 x 550 Air filter F5 or F6 Physical data Connection diameter, chilled and hot-water coil in 1/2 gas 1/2 gas Spigot connection diameter mm 200 200 Length x depth x height mm 900 x 665 x 270 1100 x 815 x 270 Unit weight (standard) kg 31 40 * Fan speed: L = Low, M = Medium, H = High ** Eurovent conditions: Entering air temperature 27°C/47% rh, entering water temperature 7°C, water temperature difference 5 K. *** Eurovent conditions: Entering air temperature 20°C - entering water temperature 50°C, with same water flow rate as in cooling mode. **** Eurovent conditions: Entering air temperature 20°C - entering water temperature 70°C, water temperature difference 10 K. † Based on a hypothetical sound attenuation for the room and the system of -21 dB(A). 1/2 gas 250 1100 x 815 x 345 50 Air distribution with Optimix linear diffusers Cooling air flow Heating air flow 113 AIR TREATMENT MODULES Air treatment 42GM Options/accessories Features t $VTUPNJTFEQSPEVDUPOSFRVFTU t 0OFTJ[FXJUIUXPQJQFQMVTFMFDUSJDIFBUFSPSGPVSQJQFDPJMTXJUIBOBJSnPX of 94 l/s, a cooling capacity of 2.2 kW and a heating capacity of 1.7 kW. t %FDFOUSBMJTFEDPNQBDUEVDUFEDIJMMFEXBUFSGBODPJMTZTUFNEFTJHOFEGPS installation in plant rooms. This allows centralised service and maintenance. t 3FMJBCMFBOEFóDJFOUIFBUJOHBOEDPPMJOHGPSPóDFCMPDLTBOEJOTUJUVUJPOBM buildings. t )JHIFóDJFODZ&6mMUFS t &YUSFNFMZMPXTPVOEMFWFM t 5IF-&$MPXFOFSHZDPOTVNQUJPO GBONPUPSBTTFNCMZJTBWBJMBCMFBTTUBOEBSE This direct-drive motor is electronically commutated (EC motor), controlled by a 0–10 V signal and allows precise, simple and quiet unit operation in a wide range of rotational speeds in variation from the original speed. t )JHIQSFTTVSFDFOUSJGVHBMGBOTDPNQBUJCMFXJUIBJSEJTUSJCVUJPOTZTUFNTVQUP 300 Pa. t $PNQBUJCMFXJUIUIF#%BJSEJòVTFSSBOHF t 4BGFGBDUPSZJOTUBMMFEFMFDUSJDIFBUFSGPSTJOHMFPSUXPTUBHFIPUXBUFSIFBUJOH t "WBJMBCMFXJUIEFNBOEDPOUSPMWFOUJMBUJPO%$7 BOE$02 sensor. t $BOCFFRVJQQFEXJUIB671$0*"2NPEVMF t -PXIZESBVMJDQSFTTVSFESPQXJUIBWBMWFNPVOUFEDPNQBUJCMFXJUIBMMDIJMMFS pump kits. t 2VJDLJOTUBMMBUJPOXJUIGBDUPSZJOTUBMMFEPQUJPOTDPOUSPMTWBMWFT Standard controls NTC communicating controller t /FUXPSLDPNNVOJDBUJPO t "RVBTNBSU&WPMVUJPOTZTUFN compatible t *"2BOE%$7NBOBHFNFOU t .PUPSJTFECMJOETBOEMJHIUJOH control Aquasmart New System Manager 35BD linear diffuser (supply and return air) 114 42GM ATM Physical data 42GM Size 1.9 (2 pipes) Fan 94 (337) Air flow l/s (m3/h) Pressure drop Pa 290 Cooling mode Total cooling capacity kW 2.20 Sensible cooling capacity kW 1.70 Water flow rate l/s (l/h) 0.11 (380) Water pressure drop kPa 65 (with 2-way valve) 4-pipe heating mode Heating capacity kW Water flow rate l/s Water pressure drop kPa Electric heater Low-capacity heating W 470 High-capacity heating W 1750 Sound levels Sound power level (inlet and radiated) dB(A) 65 Sound power level (outlet duct) dB(A) 70 Sound pressure level* dB(A) 49 NR value 45 V-ph-Hz 230-1-50 Power supply Power input W 115 Current draw A 0.81 Dimensions Coil inlet/outlet diameters in 1/2 gas Length mm 1202 Height mm 412 Depth mm 300 kg 30 Weight Based on Eurovent rating standards: Cooling: Entering/leaving air temperature = 27°C db/19°C wb – entering/leaving water temperature = 7°C/12°C. Heating (2 pipes): Entering air temperature = 20°C – entering water temperature = 50°C, same water flow rate as in cooling. Heating (4 pipes): Entering air temperature = 20°C – entering/leaving water temperature = 70°C/60°C. * Based on a hypothetical sound attenuation for the room and the system of -21 dB(A). Dimensions, mm 42GM with front fastening support with constant-flow fresh air 1202 115 Size 1.9 (4 pipes) 94 (337) 290 2.20 1.70 0.11 (380) 47 (with 2-way valve) 2.21 0.05 (190) 10 65 70 49 45 230-1-50 115 0.81 1/2 gas 1202 412 300 30 AIR TREATMENT MODULES Air treatment 42GR Options/accessories Features t $VTUPNNBEFQSPEVDUPOSFRVFTU t 5XPTJ[FTXJUIUXPQJQFQMVTFMFDUSJDIFBUFSPSGPVSQJQFDPJMTXJUIBOBJSnPX range from 103 to 109 l/s, a cooling capacity of 3.1 kW and a heating capacity range from 2.9 to 3.5 kW. t %FDFOUSBMJTFEDPNQBDUEVDUFEDIJMMFEXBUFSGBODPJMTZTUFNEFTJHOFEGPS installation in plant rooms. This allows centralised service and maintenance. t 3FMJBCMFBOEFóDJFOUIFBUJOHBOEDPPMJOHGPSPóDFCMPDLTBOEJOTUJUVUJPOBM buildings. t )JHIFóDJFODZ&6mMUFS t &YUSFNFMZMPXTPVOEMFWFM t 5IF-&$MPXFOFSHZDPOTVNQUJPO GBONPUPSBTTFNCMZJTBWBJMBCMFBTTUBOEBSE This direct-drive motor is electronically commutated (EC motor), controlled by a 0–10 V signal and allows precise, simple and quiet unit operation in a wide range of rotational speeds in variation from the original speed. t )JHIQSFTTVSFDFOUSJGVHBMGBOTDPNQBUJCMFXJUIBJSEJòVTJPOTZTUFNTVQUP 300 Pa. t $PNQBUJCMFXJUIUIF#%BJSEJòVTFSSBOHF t 4BGFGBDUPSZJOTUBMMFEFMFDUSJDIFBUFSGPSTJOHMFPSUXPTUBHFIPUXBUFSIFBUJOH t "WBJMBCMFXJUIEFNBOEDPOUSPMWFOUJMBUJPO%$7 BOE$02 sensor. t $BOCFFRVJQQFEXJUIB671$0*"2NPEVMF t -PXIZESBVMJDQSFTTVSFESPQXJUIBWBMWFNPVOUFEDPNQBUJCMFXJUIBMMDIJMMFS pump kits. t 2VJDLJOTUBMMBUJPOXJUIGBDUPSZJOTUBMMFEPQUJPOTDPOUSPMTWBMWFT Standard controls NTC communicating controller t /FUXPSLDPNNVOJDBUJPO t "RVBTNBSU&WPMVUJPOTZTUFN compatible t *"2BOE%$7NBOBHFNFOU t .PUPSJTFECMJOETBOEMJHIUJOH control Aquasmart New System Manager 35BD linear diffuser (supply and return air) 116 42GR ATM Physical data 42GR Size 1.9 Fan 109 (394) Air flow l/s (m3/h) Pressure drop Pa 395 Cooling mode Total cooling capacity kW 3.07 Sensible cooling capacity kW 2.21 Water flow rate l/s (l/h) 0.14 (504) Water pressure drop kPa 34 2-pipe heating mode Heating capacity kW 3.09 4-pipe heating mode Heating capacity kW 2.92 Water flow rate l/s (l/h) 0.07 (251) Water pressure drop kPa 12 Electric heater Low-capacity heating W 450 High-capacity heating W 1700 Sound levels Sound power level dB(A) 74 Sound pressure level* dB(A) 53 NR value 48 V-ph-Hz 230-1-50 Power supply Power input W 133 Current draw A 0.64 Dimensions Coil inlet/outlet diameters in 1/2 gas Length mm 960 Height mm 962 Depth mm 250 kg 35 Weight Based on Eurovent rating standards: Cooling: Entering/leaving air temperature = 27°C db/19°C wb – entering/leaving water temperature = 7°C/12°C. Heating (2 pipes): Entering air temperature = 20°C – entering water temperature = 50°C, same water flow rate as in cooling. Heating (4 pipes): Entering air temperature = 20°C – entering/leaving water temperature = 70°C/60°C. * Based on a hypothetical acoustic attenuation for the room and the air distribution system of -21 dB(A). Dimensions, mm Size 2.9 103 (371) 250 3.14 2.20 0.21 (752) 52 3.20 3.54 0.08 (305) 19 450 1800 66 45 40 230-1-50 126 0.91 1/2 gas 960 962 420 50 Air distribution with Optimix linear diffusers Standard installation Cooling air flow Supply air n sio en sp ng Su casi Return air Fresh air inlet Heating air flow Controller 117 MODUBOOT AIR DIFFUSERS Air treatment 35BD/SR Accessories Features t t t t t t -JOFBSEJòVTFSTXJUIIJHIJOEVDUJPOTQFDJBMMZEFTJHOFEUPCFDPOOFDUFEUPUIF Carrier 42GR Air Treatment Modules, 42BJ Individual Comfort Modules, 42EM Atmosphera and 42DW ducted fan coil units. t 5XPNBJOUZQFT - AG and AH profiles, two slots one-way and two-way blow for cold air diffusion and return air. - FH, SH, XH, LH profiles: two to five slots with Optimix damper for cold and warm air diffusion. t #%NPEFMTIBWFBTVQQMZPSSFUVSOBJS.PEVCPPU43NPEFMTIBWFB supply and return air Moduboot. t #%oEJòVTFSQSPmMFTXJUIUXPUPmWFTMPUTBOEPOFXBZPSUXPXBZ blow for cold air diffusion or return air. t 43oEJòVTFSQSPmMFTXJUIUISFFUPmWFTMPUTGPSDPMEBOEXBSNBJS diffusion. t 'PVSOPNJOBMMFOHUIToNNGPSUIF#%BOE – 1350 – 1500 – 1800 mm for the 35SR. t $IPJDFPGNPEFMTBMMPXTBJSUISPXBEKVTUNFOUBDDPSEJOHUPUIFSFRVJSFEBJSnPX t %BNQFSQPTJUJPOPGUIF0QUJNJYEJòVTFSDIBOHFTBVUPNBUJDBMMZXJUIUIF primary air temperature. t $PNQSJTFTBHBMWBOJ[FETIFFUNFUBMQMFOVNXJUINNUIJDLmCSFHMBTT acoustic and thermal internal insulation. t "FSPEZOBNJDEJòVTFSEFTJHOQSPWJEFTVOJGPSNBJSEJTUSJCVUJPOXJUIPVU disturbing draughts. t 'SPNGVMMZDPMEUPGVMMZXBSNQPTJUJPOUIFEBNQFSPQFSBUJPOQSPWJEFTBEKVTUFE air diffusion to ensure optimum comfort in the occupied space. 3FUVSOBJSEJòVTFST %VNNZEJòVTFST %JòVTFSFOEUSJNTUSJQT "MJHONFOUDIBOOFMT .PVOUJOHCSBDLFUT 118 35BD/SR 35BD supply or return air Model AG AH VH/MH GH/JH BH/QH CH No. of slots 2 2 2 2 3 4 5 5 Duct diameter mm 159/199 159/199 159/199 199 199 199 199 199 35BD supply or return air Optimix Nominal diffuser length mm 600 1200 1500 Plenum length mm 473 939 1235 Overall height mm 270.4 270.4 270.4 600 1200-1350 1500 539 1139 1439 280.8 280.8 280.8 Model No. of slots 3 3 4 4 5 SH EH/FH KH/XH UH LH/NH Duct diameter mm 199 199 199 199 199 Nominal diffuser length Plenum length mm mm Overall height mm 1200-1350 1500 280.8 220.8 1139 1439 Optimix diffuser profiles EH FH LH KH SH XH UH Cold supply air damper position Warm supply air damper position NH 35SR supply/return air Model No. of slots Duct diameter mm 3 159/199* VH/MH 4 159/199** GH 4 159/199** JH 5 159/199*** CH/QH 5 159/199*** BH * 159 mm for diffuser length 1200-1350 mm only ** 159 mm for diffuser length 1500 mm only *** 159 mm for diffuser length 1800 mm only Nominal diffuser length mm Plenum length mm Supply section length mm Return section length mm Overall height mm 1200-1350 1500 1800 1139 1439 1739 742 867 1067 388 563 663 280.8 280.8 280.8 Nominal diffuser length mm Plenum length mm Supply section length mm Return section length mm Overall height mm 1200-1350 1500 1800 1139 1439 1739 742 867 1067 388 563 563 280.8 280.8 280.8 35SR supply/return air Optimix Model No. of slots EH/FH SH XH UH KH LH NH 3 3 4 4 4 5 5 Duct diameter mm 199 199 199 199 199 199 199 Other diffuser profiles AH AH TWB QH TWB MH OWB GH OWB OWB BH VH GH TWB OWB CH TWB OWB - One-way blow TWB - Two-way blow 119 JH MODULINE AIR DIFFUSERS Air treatment 37A Accessories Features t 0OFPSUXPXBZ5CBSPS continuous, 2-way return air diffuser (AG, AH) t 0OFPSUXPXBZ5CBSPSDPOUJOVPVT dummy units (AG, AH) t &OEUSJNNJOHQJFDFBMM t "MJHONFOUDIBOOFMT"("4 t 1MBTUJDCMBOLJOHQJFDFBMM t $POTUBOUWPMVNFDPOUSPMLJUBMM t 7BSJBCMFBJSWPMVNFDPOUSPMMFSXJUI Moduline thermostat (all) t 7BSJBCMFBJSWPMVNFDPOUSPMMXJUI room thermostat (all) t .JOJNVNBJSnPXDPOUSPMMFS t 8BSNVQTXJUDI t 7BSJPVTTVTQFOTJPOBDDFTTPSJFT t 7BSJPVTQMFOVNBDDFTTPSJFT t 7BSJPVTDPOUSPMBDDFTTPSJFT t 5ISFFUZQFTPGUFSNJOBMTXJUIOPNJOBMBJSnPXTGSPNUPMT t 8JEFSBOHFPGDBQBDJUJFTXFJHIUTBOEQIZTJDBMEJNFOTJPOT t "JSEJTUSJCVUJPOBOEBJSWPMVNFnPXDPOUSPMDPOTUBOUPSWBSJBCMFWPMVNFBSF integrated in the terminal itself. t 0OFQJFDFTFMGDPOUBJOFEVOJUTDBOCFVTFEJOBOZUZQFPGBJSUSFBUNFOUVOJU ducted central station air handlers or packaged indoor or outdoor air conditioners. t $POEJUJPOFEBJSJTEJTUSJCVUFEUISPVHIMJOFBSEJòVTFSTMPUTJOUIFDFJMJOH t "WBJMBCMFJOTJ[FTUPNBUDITUBOEBSEGBMTFDFJMJOHNPEVMFT t (BMWBOJTFETUFFMQMFOVNTB t 1FSGPSBUFETIFFUTUFFMEJTUSJCVUJPOQMBUFC t /FPQSFOFCFMMPXTXIJDIFYQBOEBOEDPOUSBDUXJUIUIFDPOUSPMQSFTTVSFD t 'FMUDPBUFECFMMPXTTUPQTDPOUSPMUIFOPJTFMFWFME t 5IFSNBMBOEBDPVTUJDJOTVMBUJPOF t "FSPEZOBNJDBMMZQSPmMFEDFOUSBMBJSHVJEFG t "DPVTUJDJOTVMBUJPOBUUFOVBUFTBJSnPXOPJTFH t "JSEJòVTFSBTTFNCMZPGFYUSVEFEBMVNJOJVNI 120 37A Series 37AG – nominal lengths 1200 and 1500 mm (active length 900 mm), air flow 56 l/s Nominal plenum height mm 180 Plenum size mm 178 x 178 Overall unit height mm 327 Width mm 181.5 Weight kg 10 230 229 x 229 378 232.5 12 280 279 x 279 428 282.5 16 37AG – nominal length 1500 mm (active length 1200 mm) – air flow 74 l/s Nominal plenum height mm Plenum size mm Overall unit height mm Width mm Weight kg 230 229 x 229 378 232.5 15 280 279 x 279 428 282.5 19 180 178 x 178 327 181.5 12 37AG: Air flow range: 19-173 l/s 37AH – nominal lengths of 1200 and 1500 mm (active length 900 mm) – air flow 97 l/s Nominal plenum height mm Plenum size mm Overall unit height mm Width mm Weight kg 230 229 x 229 388 232.5 15 280 279 x 279 438 282.5 16 37AH: Air flow range: 47-236 l/s 37AS – nominal lengths of 1200 and 1500 mm (active length 900 mm) – air flow 56 l/s Nominal plenum height mm Plenum size mm Overall unit height mm Width mm Weight kg 127 127 x 178 170 288 11.5 37AS: Air flow range: 19-78 l/s 121 AIR HANDLING UNITS Air treatment 39SQ Options Features t 0VUEPPSJOTUBMMBUJPO t *OTQFDUJPOTFDUJPOJOCFUXFFO heating and cooling coils t 3FWFSTFEIPUDIJMMFEXBUFSDPJMT t %JòFSFOUJBMQSFTTVSFHBVHFT t %JòFSFOUJBMQSFTTVSFUBQT t %JSFDUFYQBOTJPO3"SFGSJHFSBOU coil t -JHIUJOHXJUITXJUDI t %PPSTBGFUZTDSFFO t 7BSJBCMFTQFFEESJWFXJUIJOUFHSBUFE disconnect switch t 3VOBSPVOEDPJMTGPSFOFSHZSFDPWFSZ t )ZHJFOJDPQUJPOTGPSIPTQJUBM laboratory applications: class 3 dampers, F9 fanal filter, inspection sections t &NQUZTFDUJPO t /FXHFOFSBUJPOTUBOEBSEJTFEBJSIBOEMJOHVOJUTGPSUFSUJBSZBOEDPNNFSDJBM applications. t &VSPWFOUDFSUJmFEQFSGPSNBODFT t 4UBOEBSEJTFEDPNQPOFOUTGPSTIPSUEFMJWFSZUJNFUBSHFUXFFLT BOE competitive price positioning. t i$MFBODPODFQUwEFTJHOXJUITNPPUIJOUFSOBMTVSGBDFTGPSFBTZDMFBOJOHBOE better air quality. t NNEPVCMFTLJODPOTUSVDUJPOGPSHPPEUIFSNBMJOTVMBUJPOBOEMPXOPJTF operation. t 5ISFFCBTJDDPOmHVSBUJPOT - Exhaust unit - Supply unit with a single fan - Combined return and supply unit with two fans t &JHIUTJ[FTXJUIBJSnPXTGSPNUPN3/s (1400 to 26300 m3/h). t (BMWBOJTFETUFFMGSBNFBOEDBTJOHXJUIMBSHFIJOHFEBDDFTTEPPST t $BTJOHQFSGPSNBODF&/ BJSMFBLBHF-UIFSNBMUSBOTNJUUBODF5 thermal bridging TB3. t %PVCMFPSTJOHMFNJYJOHTFDUJPO t 1SFIFBUJOHIPUXBUFSDPJM t (QMFBUFEPSBOE'CBHmMUFST t )PUXBUFSDPJMPSFMFDUSJDIFBUFST t $IJMMFEXBUFSDPJM t #FMUESJWFOGPSXBSECBDLXBSEDVSWFEGBOTPSEJSFDUESJWFQMVHJOGBOT 122 39SQ Physical data 39SQ Height (including base frame) Width 1- Exhaust unit Air flow Length 2 - Supply unit heating Air flow Heating capacity Length 3 - Supply unit heating and cooling Air flow Heating capacity Cooling capacity Length 4 – Supply unit: mixing/heating/cooling Air flow Heating capacity Cooling capacity Length 5 – Combined exhaust and supply unit Air flow Heating capacity Cooling capacity Length total Length section 1 Length section 2 Electric heater option Heating capacity 1 Heating capacity 2 Heating capacity 3 Heating capacity 4 Heating capacity 5 Pre-heating coil option Heating capacity 1 – Exhaust unit Exhaust fan mm mm 0402 560 738 0404 800 738 0604 800 1058 0606 1120 1058 0806 1120 1378 0808 1440 1378 1008 1440 1698 1010 1760 1698 m3/s mm 0.58 660 1.17 820 1.75 900 2.63 1060 3.5 1140 4.67 1220 5.83 1300 7.29 1540 m3/s kW mm 0.58 24.5 1380 1.17 48.5 1540 1.75 74.5 1620 2.63 112.3 1780 3.5 140.1 1860 4.67 188.5 1940 5.83 243.7 2180 7.29 304.4 2340 m3/s kW kW mm 0.54 22.5 10 1860 1 42.6 19.2 2020 1.72 73.3 33.1 2100 2.58 110 49.9 2260 3.2 132.7 63 2340 4.36 181.1 86.2 2420 5.73 241 112.3 2660 7.1 300.2 139.7 2820 m3/s kW kW mm 0.54 22.5 10 2180 1 42.6 19.2 2340 1.72 73.3 33.1 2420 2.58 110 49.9 2660 3.2 132.7 63 2740 4.36 181.1 86.2 3060 5.73 241 112.3 3220 7.1 300.2 139.7 3460 m3/s kW kW mm mm mm 0.54 22.5 10 3220 1 42.6 19.2 3540 1.72 73.3 33.1 3700 2.58 110 49.9 4180 3.2 132.7 63 4340 4.36 181.1 86.2 4820 2450 2370 5.73 241 112.3 5140 2530 2610 7.1 300.2 139.7 5700 2930 2770 kW kW kW kW kW 7.5 11.3 15 18.8 30 7.5 15 22.5 30 37.5 18 27 36 45 54 27 36 54 63 81 36 48 72 84 108 36 60 96 120 144 45 75 120 150 180 60 90 150 180 225 kW 6.4 12.2 20.9 31.4 38.8 53 69.6 86.5 2 – Supply unit heating Return air damper G4+F7 filter Heating coil 2 rows Supply fan 3 – Supply unit heating and cooling Return air damper G4 + F7 filters Heating coil 2 rows Cooling coil 6 rows Supply fan 4 – Supply unit: mixing/heating/cooling Return air damper Fresh air damper G4 + F7 filters Heating coil 2 rows Cooling coil 6 rows Supply fan 5 – Combined exhaust and supply unit Return air damper Return fan Exhaust damper Mixing damper Fresh air damper G4 + F7 filters Heating coil 2 rows Cooling coil 6 rows Standard conditions: Heating: air -10°C/90% rh, +25°C, water 80/60°C Cooling: air 28°C/50% rh, +16°C, water 7/12°C Pre-heating: air -5°C, +5°C, water 80/70°C External static pressure 300 Pa Notes on dimensions: t t t t t "MMEJNFOTJPOTBSFGPSJOEPPSVOJUTXJUICBDLXBSEDVSWFEGBOTFYDFQUTJ[FUIBUIBT dimensions with a forward-curved fan $BTJOHMFOHUIJTFYDMVTJWFPGSFUVSOBJSEBNQFS &MFDUSJDIFBUFSPQUJPOMFOHUIWBSJFTXJUIIFBUJOHDBQBDJUZ 1SFIFBUJOHDPJMPQUJPOMFOHUINN $POUBDUZPVS$BSSJFSSFQSFTFOUBUJWFGPSDFSUJmFEEJNFOTJPOBMESBXJOHT Hospital exhaust and supply units with run-around coil for energy recovery 123 FRESH AIR UNITS WITH ENERGY RECOVERY Air treatment 39SQC/R/P Options/accessories Features t 0VUEPPSJOTUBMMBUJPO t 3FWFSTFEFYUSBDUTVQQMZBJSEVDU connections t -FGUIBOEXBUFSDPOOFDUJPOT service side t 0VUEPPSBJSQSFIFBUFSUPQSFWFOU air-to-air heat exchanger freezing at very low outside air temperatures t "JSIFBUFSIPUXBUFSPSFMFDUSJDBM heater) t "JSDPPMFSDIJMMFEXBUFSDPJM t *OTQFDUJPODIBNCFSCFUXFFO heating and cooling coils t 1SP%JBMPHIVNBOJOUFSGBDFMPDBMPS remote installation) t *OTQFDUJPOXJOEPXT t &YUSBDUFYIBVTUPVUTJEFTVQQMZBJS isolating dampers t (GSFTIBJSQSFmMUFS t 4PVOEBUUFOVBUPSTBDDFTTPSZ t %JSFDUFYQBOTJPO3"SFGSJHFSBOU coil t +#VT#"$OFUDPNNVOJDBUJPOT gateways t $PPMIFBUDIBOHFPWFSDPJMGPSIFBU pump applications t $PBUFEDPJMT t 3FDJSDVMBUJPOEBNQFS4213 t 5ISFFWFSTJPOTJOOJOFTJ[FTXJUIBJSnPXTGSPNUPN3/s (700 to 30000 m3/h). t 42VOJUTBSFEFTJHOFEUPTVQQMZGSFTIBJSUPBOZUZQFPGCVJMEJOH5IFFóDJFOU air-to-air heat exchanger recycles the heat from the exhaust air, pre-heats cold outdoor air in winter and pre-cools hot outdoor air in summer, resulting in impressive energy savings. t &VSPWFOUDFSUJmFEQFSGPSNBODFT t )JHIFóDJFODZVOJUTXJUIDPVOUFSnPXQMBUF$NPEFMT PSSPUBSZIFBU exchangers (R models) with a thermal efficiency up to 85%. t $BTJOHQFSGPSNBODF&/ BJSMFBLBHF-UIFSNBMUSBOTNJUUBODF5 thermal bridging TB3. t 4UBOEBSEFóDJFODZVOJUTXJUIDSPTTnPXQMBUFIFBUFYDIBOHFST1NPEFMT with a thermal efficiency up to 54%. t 1MVHQMBZJOTUBMMBUJPOUIBOLTUPGBDUPSZNPVOUFEDPOUSPMTZTUFN t %FMJWFSFEJOPOFQJFDFXJUIJOUFHSBUFEIFBUJOHBOEDPPMJOHDPJMTPOMZUIF 39SQR 1212 is delivered in two pieces). t 'JFMETFQBSBCMFDBTJOHJOUXPQJFDFTUPGBDJMJUBUFJOTUBMMBUJPOJOFYJTUJOHCVJMEJOHT t 1MVHGBOTXJUIWBSJBCMFGSFRVFODZESJWF t 'FóDJFODZmMUFST t .BJODPOUSPMTZTUFNGVODUJPOT - Air flow control: constant volume, constant pressure, variable volume (demand ventilation with CO2 sensor) - Temperature control: extract or supply air temperature, room temperature sensor - Summer night free-cooling control - Alarm indication: temperature too low, coil frosting, clogged filters, etc. - Easy local or remote access by integrated web server (no specific software required) - RS485 communication port \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 124 39SQC/R/P Physical data Model Size Weight Unit without coils Unit with reheating and cooling coils Unit air flow Maximum Minimum Unit thermal efficiency* Unit external static pressure At max. air flow (low static fan) At max. air flow (high static fan) Specific unit fan power** Unit sound data*** Sound power level, casing radiated Sound power level, extract duct Sound power level, supply duct Heat reclaim heat exchanger Material Capacity control Exhaust and supply fans Fan diameter Drive Rated motor power (low static) Rated motor power (high static) Exhaust and supply air filters Outside air pre-heating coil Supply air reheating coil Supply air cooling coil Control system 39SQC 39SQR 0405 0506 0606 0606 0707 0808 0909 1010 1111 1212 1412 1416 39SQP 0405 0506 0606 0707 0808 0909 1010 kg kg 218 301 294 399 210 277 275 360 324 423 395 518 536 712 578 783 688 923 m3/s 0.43 m3/h m3/s m3/h % 1565 0.20 737 94 Pa 500 Pa 1550 kW/m3/s 2.4 dB(A) dB(A) dB(A) mm kW kW 345 469 328 428 0.72 0.88 1.25 1.70 2580 0.34 1225 94 3150 0.43 1549 94 4500 0.43 1549 77.5 6125 0.62 2247 78 150 600 2.3 400 2.3 1200 500 2.1 2.1 700 700 2000 1700 2.1 2.5 385 509 516 660 586 757 717 952 852 1121 1043 1346 1623 2026 2605 3049 2.22 2.81 3.47 4.20 5.00 5.83 8.19 0.68 1.04 1.25 1.70 2.22 2.81 3.47 8000 0.91 3265 78 10125 1.25 4501 79 12500 1.48 5328 79 15125 1.91 6882 79 18000 2.18 7847 79 21000 2.64 9500 75 29500 8.19 13000 76 2450 0.20 737 62 3750 0.34 1225 63 4500 0.43 1549 63 6125 0.62 2247 64 8000 0.91 3265 64 10125 1.25 4501 63 12500 1.48 5328 62 120 950 1.9 800 2 150 1050 1.7 610 960 1.3 480 940 1.1 400 650 2.2 800 1.9 0 650 2.1 450 2 50 1300 1.8 550 1.9 150 1000 1.7 73 79 89 69 76 86 73 79 89 69 76 86 68 79 89 70 81 90 67 66 77 75 84 82 Cross-flow plate Aluminium Bypass damper 69 79 86 73 82 88 67 77 84 73 79 89 69 78 86 400 500 500 630 2X500 2X560 225 280 315 400 400 500 2.2 5.5 4 7.5 5.5 11 5.5 11 2X4 2X5.5 2X5.5 2X7.5 1.1 1.1 1.5 2.2 2.2 1.5 2.2 3 4 5.5 Pleated filter 100 mm, filter efficiency F7 2.2 5.5 4 7.5 68 68 71 70 73 68 74 74 77 76 79 75 84 84 88 87 89 85 Counter-flow plate Rotary Aluminium Aluminium Bypass damper Variable speed drive Plug fan (backward curved) 225 280 280 280 315 400 Frequency inverter 0.55 1.1 1.5 1.5 2.2 2.2 1.5 2.2 3 3 4 5.5 Bag filter 500 mm, filter efficiency F7 Hot-water coil or electric heater (option) Hot-water coil or electric heater (option) Chilled-water coil (option) Digital control with web server 280 Colour code: RAL 7035 Chassis paint colour * Thermal efficiency of supply air at 2 m/s with the effect of supply air fan, outside air -10°C, extract air 22°C/50%. ** Specific fan power with clean filters at 2 m/s and 200 Pa. *** Sound power at 2 m/s and 200 Pa. Data for standard unit without optional coils and dampers. Electrical data Model 39 SQC 0405 SQC 0506 SQC 0606 SQP 0405 SQP 0506 SQP 0606 Built-in main disconnect switch Power circuit Nominal power supply V-ph-Hz 400-3-50 neutral Voltage range V 360-440 kW 3 4.77 6.37 Maximum unit power 2.5 4 4 mm2 Maximum supply cable size A 25 25 25 Main switch kA 15 15 15 Short circuit unit capacity 20 25 25 Recommended power line fuse A protection Built-in 24 V control transformer Control circuit power SQR 0606 SQR 0707 SQP 0707 SQR 0808 SQP 0808 SQR 0909 SQP 0909 SQR 1010 SQP 1010 SQR 1111 SQR 1212 SQR 1412 SQR 1416 6.37 4 25 15 25 8.75 6 40 15 35 11.75 6 40 15 35 11.75 6 40 15 35 15.75 10 63 15 50 22.75 16 63 15 63 22.75 16 63 15 63 22.75 16 63 15 63 30.75 25 80 15 80 Note: Electric pre-heater and reheater have separate power supply. Hospital exhaust and supply units with run-around coil for energy recovery 125 AIR HANDLING UNITS Air treatment 39HQ Options Features t TUBJOMFTTTUFFM t %JSFDUESJWFGBOT t "MMUZQFTPGIVNJEJmDBUJPOTZTUFNT including infrasonic t 'MBUQBDLPQUJPOGPSTJUFBTTFNCMZ t )FBUSFDPWFSZTZTUFNTSVOBSPVOE coil, plate heat exchanger and thermal wheels) t 8JEFTFMFDUJPOPGTUBOEBSEBDDFTTPSJFT t -TUBJOMFTTTUFFMESBJOQBOXJUI PVC wall lining in the outside air inlet section and filter section t "JSPWJTJPOJTBNPEVMBSDPOTUSVDUJPOUIBUDBOCFGVMMZDVTUPNJTFEUPQSPWJEF the required performance for any application. t 4QFDJBMOFXDBTJOHTFODPNQBTTPOMZIJHIRVBMJUZDPNQPOFOUTJODMVEJOHmMUFST heat recovery systems, fan assemblies, cooling and heating coils, humidifiers and attenuators. t 5IF"JSPWJTJPOSBOHFBMTPQBZTTQFDJBMBUUFOUJPOUPBJSRVBMJUZBOESFEVDUJPO of the energy required to cool, heat, humidify and supply the conditioned air. t "JSPWJTJPOJTBWBJMBCMFJOBMBSHFTFMFDUJPOPGTJ[FTBOEBSSBOHFNFOUTTVJUBCMF for many different applications. t "QQMJDBUJPOTJODMVEFMFJTVSFBOEFWFOUDPNQMFYFTUIFBUSFTNVTFVNTMJCSBSJFT offices in companies and government institutions, shopping centres, supermarkets, department stores and educational establishments, as well as oil drilling rigs, airports and cruise ships. t *OBEEJUJPO"JSPWJTJPOJTBMTPJEFBMJOIFBMUIDBSFBOEJOJOEVTUSJFTXJUITUSJOHFOU hygiene requirements. Features High-efficiency centrifugal fan Special sorption heat recovery wheels Filters are easily removable Environmentally sound t /PQBJOUUSFBUNFOUSFRVJSFEBGUFSUIFQSPEVDUJPOQSPDFTT t SFDZDMBCMFDPNQPOFOUT t -PXFOFSHZVTBHFEVFUPPQUJNJTFEDPNQPOFOUTFMFDUJPO t )JHIFóDJFODZIFBUSFDPWFSZTZTUFNTBWBJMBCMF Technical specification (in accordance with EN1886) t )FBUUSBOTGFSGBDUPSDMBTT5 t 5IFSNBMCSJEHJOHGBDUPS5# t "JSUJHIUOFTTDMBTT#- t .FDIBOJDBMTUSFOHUIDMBTT"%* t 'JMUFSCZQBTTMFBLBHF - class F7 for standard slide-in construction - class F9 for special slide-in construction - class F9 for built-in construction Generously sized access doors 126 39HQ Airovision Rigid construction 1 2 3 12 1 2 Carrier Holland Heating profiled steel frame construction with purpose-built corner and centre posts Panels with 60 mm thick thermal insulation Robust base frame made of galvanised steel box profile 18 9 7 16 19 60 mm High corrosion resistance 4 5 6 7 8 9 316L stainless steel drain pan with PVC wall lining in the outside air inlet section and filter section (option) Filters held in 316L stainless steel frames Anti-corrosion protection available Internal and external panels made of highquality prepainted galvanised sheet steel Cooling coils with integrated stainless steel drain pan and plastic droplet eliminator housed in an aluminium frame Special panel design and frame detail eliminate the risk of condensation forming in the panels 2 17 21 22 15 11 14 8 3 6 20 10 5 4 13 Easy maintenance High-quality built-in components 10 Various inspection options with generously sized clear opening access doors 11 Completely smooth internal surfaces 12 Filters easily removable 13 Drain pan in the outside air inlet section and filter section equipped with drain (option) 14 Cooling coil drain pan fully accessible for cleaning/disinfection 15 Moisture eliminator after the cooling coil easily removable 16 Long-life fan and motor bearings 17 Fans removable from the side 18 Special sorption heat recovery wheels for optimised recovery of heat, cold and humidity 19 High-efficiency centrifugal low-noise fans, mounted on vibration isolators with low transmission factor 20 Aluminium dampers with UV-resistant double nylon bearings 21 Skrim faced sound absorption splitters 22 Matched high-efficiency belt drives Central station air handling unit range (based on a nominal filter loading of 1.11 m3/s) Width 4 Height 0.56 2.5 1.11 4 1.67 6 8 10 12 14 16 18 20 Preferred range 5 6 7 8 9 10 11 12 0.69 1.39 2.22 0.83 1.67 2.50 3.33 1.81 2.92 3.89 2.22 3.33 4.44 5.56 2.50 3.75 5.00 6.39 7.50 2.78 4.17 5.56 6.94 8.33 3.06 4.72 6.11 7.64 9.17 3.33 5.00 6.67 8.33 10.00 11.67 Combination with heat recovery 13 14 15 16 17 18 19 20 21 22 23 24 25 5.56 7.22 9.03 10.83 12.78 14.44 5.83 7.78 9.72 11.67 13.61 15.56 6.39 8.33 10.56 12.50 14.72 16.67 6.67 8.89 11.11 13.33 15.56 17.78 7.22 9.44 11.94 14.44 16.67 18.89 7.50 10.00 12.50 15.00 17.50 20.00 22.50 10.56 13.33 15.83 18.61 21.11 23.89 11.11 13.89 16.67 19.44 22.22 25.00 27.78 11.67 14.72 17.50 20.56 23.33 26.39 29.17 12.22 15.28 18.33 21.39 24.44 27.50 30.56 12.78 16.11 19.17 22.50 25.56 28.89 31.94 13.33 16.67 20.00 23.33 26.67 30.00 33.33 17.50 20.83 24.44 27.78 31.39 34.72 Other sizes 3 Note: All air flow values are in m /s. Larger unit sizes are possible. Module dimension: External width: External height: Base frame height: 160 mm n x module plus 98 mm n x module plus 98 mm 60 mm or 62 mm Example: Width: Height: Nominal air flow: type 39HQ12.10 12 x 160 plus 98 = 2.018 mm 10 x 160 plus 98 = 1.698 mm 8.33 m3/s 127 AIR HANDLING UNITS Air treatment 39MQ Options/accessories Features t 0VUEPPSJOTUBMMBUJPOCJUVNFOPS steel profile roof) t 3FWFSTFEFYUSBDUTVQQMZBJSEVDU connections t -FGUIBOEXBUFSDPOOFDUJPOT service side t 0VUEPPSBJSQSFIFBUFSUP prevent air-to-air heat exchanger freezing at very low outside air temperatures t 3PUBSZIFBUFYDIBOHFS temperature, enthalpy or sorption types, supplied in divided version sizes 60 to 240. t $SPPTnPXIFBUFYDIBOHFS aluminium or corrosion resistant (coated plates) t "JSIFBUFSIPUXBUFSPS electrical heater) t "JSDPPMFSDIJMMFEXBUFSDPJM t $PPMIFBUDIBOHFPWFSDPJMGPS heat pump applications t %JSFDUFYQBOTJPO3" refrigerant coil t *OTQFDUJPODIBNCFSCFUXFFO heating and cooling coils t *OTQFDUJPOXJOEPXT t &YUSBDUFYIBVTUPVUTJEFTVQQMZ air isolating dampers t 3FDJSDVMBUJPONJYJOHEBNQFS t 4PVOEBUUFOVBUPST t $PBUFEDPJMT t "JSEJTUSJCVUPSBGUFSDFOUSJGVHBM fan t TJ[FTXJUIBJSnPXTGSPNUPNTUPNI t 5IFNPEVMBSDPOTUSVDUJPOJTIJHIMZnFYJCMFUPDPNCJOFUIFNPTUPQUJNJ[FEGVODUJPOT and to offer the best running- and investment costs e.g. the type of heat exchangers and fans with the highest efficiencies, combined with filters and coils with low pressure drop. t &VSPWFOUDFSUJmFEQFSGPSNBODFT t 'SBNFQBOFMTNBEFPGBMV[JOD";DMBTT$DPSSPTJPOQSPUFDUJPOTBNFBT aluminium) t $BTJOHQFSGPSNBODF&/ BJSMFBLBHF-UIFSNBMUSBOTNJUUBODF5UIFSNBM bridging TB4 with insulating mineral wool 50mm thickness & 50Kg/m3 density t )JHIFóDJFODZVOJUTXJUIDPVOUFSnPXQMBUFTJ[FTUP PSSPUBSZIFBU exchangers (all sizes) with a thermal efficiency up to 87%. t 4UBOEBSEFóDJFODZVOJUTXJUIDSPTTnPXQMBUFIFBUFYDIBOHFSTBMMTJ[FT XJUIB thermal efficiency up to 65%. t 4UBOEBSEFóDJFODZVOJUTXJUISVOBSPVOEDPJMIFBUFYDIBOHFSTBMMTJ[FT XJUIB thermal efficiency up to 55%. t -BSHFDIPJDFPG%BNQFST&/TFBMJOHDMBTT TIVUPòEBNQFST.JYJOH dampers (two of three dampers for recirculation) t $FOUSJGVHBM'BOTBMMTJ[FT BSFBEPVCMFJOMFUCFMUESJWFODFOUSJGVHBMGBOBWBJMBCMFBT backward-curved blades with an efficiency of up to 82% or forward curved blades with an efficiency of up to 73%. t 1MVH'BOTXJUIWBSJBCMFGSFRVFODZESJWFFóDJFODJFTPGVQUPBOEGFBUVSFTWFSZ low sound levels in the lower frequencies. t 1MVH'BOTBSFBWBJMBCMFBTTJOHMFTQFFE"$JOEVDUJPONPUPSBMMTJ[FT PS&$GBOXJUI the build in speed control (1 plug fan for size 10 to 40, 2 plug fan from size 50 to 240) with permanent magnet rotor (efficiency eqivalent or better than IE4). t $PNQBDUmMUFS(PSCBHmMUFST(UP'FóDJFODZ 128 39MQ Physical data 1500 2000 3000 5000 10000 20000 50000 30000 90000 m3/h 240 190 150 120 100 80 60 50 40 30 25 20 15 10 0,4 0,7 Extract air 1 2 3 5 10 15 20 25 m3/s Supply air Unit size Rotary Heat Exchanger 40 50 60 80 100 120 150 190 240 Standard Width 970 1120 1270 1420 1570 1720 2020 2170 2170 2370 2590 2890 3190 3490 Rotary Heat Exchanger Width - - - - - - - - 2320 2520 2890 3040 3720 4020 Single height unit Height* 520 595 670 745 820 895 1045 1120 1270 1420 1570 1720 2170 2470 Double height unit Height* 970 1120 1270 1420 1570 1720 2020 2240 2540 2840 3140 3440 4340 4940 Length 2160 2160 2460 2460 2760 3060 2910 3280 3210 3960 4260 4560 5010 5530 C1E Weight kg 10 15 20 25 30 430 520 660 760 920 1100 1470 1980 2140 2630 3250 3990 6290 7610 2910 2910 3210 3210 3510 3810 3660 4030 4030 4930 5230 5530 5980 6430 Weight kg 500 610 770 870 1080 1270 1690 2250 2470 3050 3890 4690 7220 8600 Length 2680 2680 3130 3130 3430 3880 4030 4400 4400 5450 5900 6200 6430 7100 Length C2E C3E C4E C5E C6E Weight kg 480 580 730 810 1010 1220 1700 2230 2480 3160 3870 4660 6870 8280 Length 3430 3430 3880 3880 4180 4630 4780 5220 5220 6420 7020 7170 7400 8000 Weight kg 560 660 840 930 1180 1390 1930 2560 2830 3610 4560 5320 7790 9180 Length 2680 2680 3130 3130 3430 3880 3730 4100 4100 5080 5380 5680 6430 7100 Weight kg 480 570 720 800 1010 1220 1630 2120 2330 2970 3620 4390 6860 8280 Length 3430 3430 3880 3880 4180 4630 4480 4850 4850 6050 6350 6650 7400 8000 550 660 840 920 1180 1380 1850 2410 2670 3370 4280 5060 7790 9170 Weight kg * 39MQ 10-150 : Height excl. Base Frame Z. 39MQ 190-240 : Height incl. base frame. Extract air Supply air Unit size Recirculated air 10 15 20 25 30 40 50 60 80 100 120 150 190 240 Width 970 1120 1270 1420 1570 1720 2020 2170 2170 2370 2590 2890 3190 3490 Single height unit Height* 520 595 670 745 820 895 1045 1120 1270 1420 1570 1720 2170 2470 Double height unit Height* 970 1120 1270 1420 1570 1720 2020 2240 2540 2840 3140 3440 4340 4940 Length 2240 2240 2390 2390 2540 2840 2690 2840 2990 3660 3810 3960 4410 5080 250 280 350 390 470 560 800 900 1000 1300 1560 1900 2320 3040 3060 3060 3210 3210 3360 3660 3510 3660 3810 4410 4560 4710 5380 5980 M1E Weight kg M2E Length Weight kg M3E Length Weight kg M4E Length Weight kg Length M5E Weight kg Length M6E Weight kg 330 400 480 560 640 780 1050 1180 1320 1660 2140 2460 3250 3940 3580 3580 3880 3880 4180 4780 4480 4780 5080 5980 6350 6650 7550 8820 390 450 560 620 760 940 1270 1470 1630 2060 2660 3150 3930 5100 4400 4400 4700 4700 5000 5600 5300 5600 5900 6950 7250 7620 8520 9720 480 560 690 790 940 1150 1550 1760 1960 2530 3250 3800 4850 6000 2610 2610 2910 2910 3210 3660 3360 2990 2990 3590 3810 3960 4710 5080 360 430 530 580 750 910 1220 1360 1520 1950 2510 2990 4190 5150 3430 3430 3730 3730 4030 4480 4180 3810 3880 4630 4780 4860 5680 5980 460 540 670 730 930 1150 1480 1650 1880 2430 3150 3570 5110 6050 129 Air treatment Index System architecture 130 Index Refrigerant-based air treatment units Type Range Refrigerant Cooling capacity Heating capacity Air flow, kW kW l/s Split systems Outdoor units, axial fan 38RBS R-410A 40-162 Monoblocs or split systems, ductable condenser and evaporator Horizontal units 50TZ (38FZ + 40TZ/BZ) R-407C 14.8-22.7 50YZ (38BZ + 40BZ) R-407C 14.3-22.2 Vertical units 50PZ (38PZ + 40PZ) R-407C 13-73 Rooftop units 48/50 UA/UH R-410A 44-115 131 Page - - 132 16.8-25 16-83 950-1365 950-1365 960-3530 134 136 138 44-112 2528-5550 140 AIR-COOLED CONDENSING UNITS Air treatment 38RBS Options Features t $POEFOTFSBOUJDPSSPTJPOQPTU treatment for improved corrosion resistance in urban, industrial and rural environments t $POEFOTFSXJUIQSFUSFBUFEmOTGPS improved corrosion resistance in marine environments t 7FSZMPXOPJTFMFWFM t 4PGUTUBSUFSGPSSFEVDFEDPNQSFTTPS start-up current t 8JOUFSPQFSBUJPOGPSBJSUFNQFSBUVSFT between -10°C and -20°C t 4VDUJPOBOEMJRVJEMJOFWBMWFTUP isolate the unit from the rest of the refrigerant circuit t +#VT#BD/FUPS-PO5BMLHBUFXBZT t 3FNPUF1SP%JBMPHVTFSJOUFSGBDF t 3FQMBDFBCMFmMUFSESJFSGPSFBTZmMUFS replacement without emptying the refrigerant circuit t 5FNQFSBUVSFTFOTPSLJU t .BTUFSTMBWFEJSFDU$$/CVTXJUI 39SQ t &MFWFOTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t 6OJUTJOUFHSBUFUIFMBUFTUUFDIOPMPHJDBMJOOPWBUJPOTP[POFGSJFOEMZSFGSJHFSBOU R410A, scroll compressors, low-noise fans made of a composite material and auto-adaptive microprocessor control t &YDFQUJPOBMMZRVJFUMBUFTUHFOFSBUJPO'MZJOH#JSEGBOTNBEFPGBDPNQPTJUF material. Fan motor controlled by a variable-frequency controller, to allow reduction of the fan speed, if the extra low noise option 15LS is selected. Rigid fan installation for reduced start-up noise (Carrier patent). t -PXOPJTFSFMJBCMFTDSPMMDPNQSFTTPSTXJUIMPXWJCSBUJPOMFWFM5IF compressor assembly is installed on an independent chassis and supported by anti-vibration mountings. Dynamic suction and discharge piping support, minimising vibration transmission (Carrier patent). t 3FGSJHFSBOUDJSDVJUJODMVEFTBMMDPNQPOFOUTGPSFBTZDPOOFDUJPOUPBEJSFDU expansion air handling unit: filter drier, moisture sight glass, high and low pressure switch, as well as solenoid valves for pumpdown. Two independent refrigerant circuits from size 38RBS 140 onwards. t *ODSFBTFEFOFSHZFóDJFODZBUQBSUMPBE5IFSFGSJHFSBOUDJSDVJUJODMVEFT several compressors connected in parallel. At part load, around 99% of the operating time, only the compressors that are absolutely necessary operate. At these conditions the compressors operating are more energy efficient, as they use the total condenser and evaporator capacity. t %FTJHOFEGPSZFBSSPVOEPQFSBUJPO t &MFDUSJDBMDPOOFDUJPOTBSFTJNQMJmFE t &YDFQUJPOBMFOEVSBODFUFTUT t ")6%JSFDUFYQFOTJPODPJMNBOBHFNFOUGSPN42DPOUSPMMFSXJUITJNQMF CCN bus connection. \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 132 38RBS Physical data 38RBS 039 045 050 060 070 40.4 45.9 52.4 58.5 66.7 Nominal cooling capacity, standard unit* kW kW 13.8 16.3 19.0 21.2 24.4 Power input kW/kW 2.92 2.81 2.75 2.76 2.74 EER kg 399 408 425 445 435 Weight ex-factory, standard unit** Sound levels Standard unit dB(A) 80 81 81 81 87 Sound power level 10-12 W*** Sound pressure level at 10 m**** dB(A) 49 49 49 49 55 Unit with option 15LS (very low sound level) dB(A) 79 80 80 80 80 Sound power level 10-12 W*** Sound pressure level at 10 m**** dB(A) 48 48 48 48 48 Hermetic scroll compressor, 48.3 r/s Compressors Quantity, circuit A 2 2 2 2 2 Quantity, circuit B No. of capacity steps 2 2 2 2 2 R-410A Refrigerant* Pro-Dialog+ Control type Grooved copper tubes, aluminium fins Condenser Fans Axial Flying Bird 4 fans with rotating shroud Quantity 1 1 1 1 1 Total air flow (high speed) l/s 3800 3800 3800 3800 5300 Dimensions Length x depth x height mm 2110 x 1075 x 1330 * Nominal evaporating temperature condition: 5°C, outdoor air temperature 35°C, superheat 5 K, 15 m equivalent length. ** Weight shown is a guideline only. 080 77.9 28.8 2.7 456 090 90.4 31.8 2.84 698 100 100.9 36.0 2.81 701 120 119.4 43.6 2.74 719 140 139.6 50.2 2.78 796 160 161.7 58.7 2.75 842 87 55 84 52 84 52 84 52 90 58 90 58 80 48 83 51 83 51 83 51 83 51 83 51 2 2 3 3 3 3 3 3 2 2 4 2 2 4 1 5300 2 7600 2 7600 2 7600 2 10600 2 10600 2110 x 2273 x 1330 Electrical data 38RBS 039 045 050 060 070 080 090 100 120 140 160 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V, via internal transformer Control circuit supply Maximum start-up current* Standard unit A 114.2 132.4 141.3 143.7 170.4 209.4 169.4 196.4 240.4 226.2 275.2 Unit with electronic starter option A 74.7 86.5 93.8 96.2 114.4 139.8 kW 19.5 22.3 24.5 27.9 31.2 35.8 42.3 45.6 52.5 62.4 71.6 Maximum unit power input** A 26.2 30.4 34.6 37.6 44.2 53.8 57.8 64.4 78.8 88.4 107.6 Nominal unit current draw*** A 35.6 40.0 43.8 48.6 55.8 65.8 74.3 81.8 96.8 11.6 131.6 Maximum unit current draw***’ * Maximum instantaneous starting current at 400 V nominal voltage with direct compressor starting (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). ** Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Nominal conditions: suction temperature 5°C, outside air temperature 35°C. **** Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Operating range Operating limits, standard unit 50 38RBS Evaporator Suction temperature (dew point) Condenser Entering air temperature* 45 Entering air temperature, °C 40 35 30 25 * 20 15 10 5 0 -5 -10 -15 -10 -5 0 5 10 15 20 Suction temperature, °C (dew point) 133 Minimum Maximum °C -5 15 °C -10 48 For transport and storage of the 38RBS units the minimum and maximum allowable temperatures are -20°C and +48°C. It is recommended that these temperatures are used for transport by container. Option 28 allows stable unit operation at air temperatures below -10°C and down to -20°C. SINGLE-PACKAGE COOLING UNITS Air treatment 50TZ Options/accessories Features t )FBEQSFTTVSFDPOUSPMPQUJPO accessory) t $SBOLDBTFIFBUFSPQUJPOBDDFTTPSZ t )PUXBUFSDPJMPQUJPOBDDFTTPSZ t 'MBSFDPOOFDUJPOTPQUJPO t 0VUEPPSBJSmMUFSPQUJPOBDDFTTPSZ t 5ISFFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t 6OJUTDPOTJTUPGUIFJOEPPSVOJU#;5;GPSVOJUTJ[F BOEUIFPVUEPPS unit 38FZ. t $PNQBDUMPXQSPmMFBJSDPPMFEDPPMJOHVOJUTEFTJHOFEGPSJOTUBMMBUJPOJOUIF void above false ceilings. t 6OJUDBCJOFUNBEFPGQSFQBJOUFETIFFUTUFFM"MMVOJUTJODMVEFJOUFSOBMUIFSNBM and sound insulation. t *OUFSDIBOHFBCMFVOJUQBOFMTQFSNJUBMUFSOBUJWFTVQQMZBOESFUVSOBJSQBUITPO all models. t &BTJMZUSBOTGPSNFEGSPNQBDLBHFEUPTQMJUVOJUT t 2VJFUDFOUSJGVHBMGBOTTUBUJDBMMZBOEEZOBNJDBMMZCBMBODFEGPSWJCSBUJPOGSFF operation. t 3FMJBCMFIFSNFUJDDPNQSFTTPSTGPS3$JODMVEFPWFSDVSSFOUBOEPWFS temperature protection and internal and external vibration isolators. t )FSNFUJDBMMZTFBMFEMFBLUFTUFESFGSJHFSBOUDJSDVJUXJUIEFPYJEJ[FEBOE dehydrated copper tubes. t .BTUFS-JOL**FMFDUSPOJDDPOUSPM Master Link II electronic control 134 50TZ (40TZ/BZ - 38FZ) Physical data 50TZ Packaged unit 060 072 kW 14.80 19.10 Nominal cooling capacity* kg 267 329 Weight Hermetic reciprocating compressor Compressor R-407C Refrigerant Copper tubes, pre-treated aluminium fins Evaporator section (40TZ/BZ) Evaporator fan (40TZ/BZ) One ... centrifugal Nominal air flow l/s 950 1320 Copper tubes, pre-treated aluminium fins Condenser section (38FZ) Condenser fan (38FZ) One ... centrifugal Nominal air flow l/s 1350 1650 Indoor unit 40BZ 060 40BZ 072 Outdoor unit 38FZ 060 38FZ 072 kW 13.95 17.38 Nominal cooling capacity* kg 87 116 Weight (indoor unit) kg 180 213 Weight (outdoor unit) * Based on an outdoor air dry bulb temperature of 35°C and an indoor air wet bulb temperature of 19°C. 084 22.74 381 1365 1875 40TZ 084 38FZ 084 20.25 120 261 Electrical data 50TZ (40TZ/BZ + 38FZ) 060 072 084 V 400 400 400 Nominal voltage (±10%)* kW 7.37 10.08 10.75 Nominal power input** A 18.54 17.41 19.18 Nominal current drawn** A 105 90 105 Starting current * The unit power supply is three-phase (except size 024, 230 V which is single-phase). The fan power supply is single-phase, except for sizes 072 and 084 which are three-phase. ** Based on an outdoor air dry bulb temperature of 35°C and an indoor air wet bulb temperature of 19°C and dry bulb temperature of 27°C. Dimensions, mm 50TZ 060 072 084 38FZ 060 072 084 40TZ/BZ 060 072 084 A 1500 1700 1700 A 1500 1700 1700 A 1500 1700 1700 B 560 630 630 B 560 630 630 B 560 630 630 C 1509 1709 1889 C 964 1008 1188 C 619 775 775 C A 38FZ B F D E D: E: F: 600 mm 500 mm 500 mm A C 50TZ C B D E B G F D: E: F: G*: * F 800 mm 500 mm 600 mm 500 mm For size 50TZ 060 G: 600 mm D D: E*: F: * Operating limits Zone A 40TZ/BZ Air temperature, °C Dry bulb Wet bulb Indoor Maximum 35 21 Minimum 19 14 Outdoor Maximum 46 Minimum 19* * With optional head pressure control the unit will operate at temperatures below 19°C. 135 600 mm 500 mm 500 mm For size 40BZ 060 E: 600 mm E SINGLE-PACKAGE HEAT PUMPS Air treatment 50YZ Options/accessories Features t )FBEQSFTTVSFDPOUSPMPQUJPO accessory) t )PUXBUFSDPJMPQUJPOBDDFTTPSZ t 'MBSFDPOOFDUJPOTPQUJPO t 0VUEPPSBJSmMUFSPQUJPOBDDFTTPSZ t 5ISFFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOEOPNJOBM heating capacities from 16.8 to 25.0 kW. t 6OJUTDPOTJTUPGUIFJOEPPSVOJU#;BOEUIFPVUEPPSVOJU#; t $PNQBDUMPXQSPmMFBJSUPBJSIFBUQVNQTEFTJHOFEGPSJOTUBMMBUJPOJOUIFWPJE above false ceilings. t 6OJUDBCJOFUNBEFPGQSFQBJOUFETIFFUTUFFM"MMVOJUTJODMVEFJOUFSOBMUIFSNBM and sound insulation. t *OUFSDIBOHFBCMFVOJUQBOFMTQFSNJUBMUFSOBUJWFTVQQMZBOESFUVSOBJSQBUITPO all models. t &BTJMZUSBOTGPSNFEGSPNQBDLBHFEUPTQMJUVOJUT t 2VJFUDFOUSJGVHBMGBOTTUBUJDBMMZBOEEZOBNJDBMMZCBMBODFEGPSWJCSBUJPOGSFF operation. t 3FMJBCMFIFSNFUJDDPNQSFTTPSTGPS3$JODMVEFPWFSDVSSFOUBOEPWFS temperature protection and internal and external vibration isolators. t )FSNFUJDBMMZTFBMFEMFBLUFTUFESFGSJHFSBOUDJSDVJUXJUIEFPYJEJ[FEBOE dehydrated copper tubes. t .BTUFS-JOL**FMFDUSPOJDDPOUSPM Master Link II electronic control 136 50YZ (40BZ/38BZ) Physical data 50YZ Packaged unit 060 072 kW 14.34 19.10 Nominal cooling capacity* kW 16.84 21.80 Nominal heating capacity** kg 270 332 Weight Hermetic reciprocating compressor Compressor R-407C Refrigerant Copper tubes, pre-treated aluminium fins Indoor section (40BZ) Indoor fan (40BZ) One ... centrifugal Nominal air flow l/s 950 1320 Copper tubes, pre-treated aluminium fins Outdoor section (38BZ) Outdoor fan (38BZ) One ... centrifugal Nominal air flow l/s 865 1350 Indoor unit 40BZ 048 40BZ 060 Outdoor unit 38BZ 048 38BZ 060 kg 76 87 Weight (indoor unit) kg 168 183 Weight (outdoor unit) * Based on an outdoor air dry bulb temperature of 35°C and an indoor air wet bulb temperature of 19°C. ** Based on an outdoor air wet bulb temperature of 6°C and an indoor air dry bulb temperature of 20°C. 084 22.20 25.00 385 1365 1650 40BZ 072 38BZ 072 116 216 Electrical data 50YZ (40BZ + 38BZ) 060 072 084 V 400 400 400 Nominal voltage (±10%)* Nominal power input Cooling** kW 7.57 10.10 10.92 Heating*** kW 6.97 9.07 9.58 Nominal current drawn Cooling** A 18.06 17.34 19.45 Heating*** A 17.57 15.95 17.80 A 105 90 105 Starting current * The unit power supply is three-phase (except size 024, 230 V) which is single-phase). The fan power supply is single-phase, except for sizes 072 and 084 which are three-phase. ** Based on an outdoor air dry bulb temperature of 35°C and an indoor air wet bulb temperature of 19°C. *** Based on an outdoor air wet bulb temperature of 6°C and an indoor air dry bulb temperature of 20°C. Dimensions, mm 50YZ 060 072 084 38BZ 060 072 084 40BZ 060 072 084 A 1500 1700 1700 A 1500 1700 1700 A 1500 1700 1700 C B 560 630 630 B 560 630 630 B 560 630 630 C 1509 1709 1889 C 964 1008 1188 C 619 775 775 C A 38BZ B F D E D: E: F: 600 mm 500 mm 500 mm A 50YZ C B D E F A 40BZ B G F D: E: F: G*: * 800 mm 500 mm 600 mm 500 mm For size 50YZ 060 G: 600 mm D: E*: F: * Operating limits Cooling Heating Zone Dry bulb Wet bulb Dry bulb Wet bulb Indoor air temperature °C Maximum 35 21 27 Minimum 19 14 Outdoor air temperature °C Maximum 46 24 18 Minimum 19* -15 * With optional head pressure control, the unit will operate at temperatures below 19°C. 137 600 mm 500 mm 500 mm For size 40BZ 060 E: 600 mm D E VERTICAL AIR-TO-AIR HEAT PUMPS Air treatment 50PZ Options/accessories Features t )FBEQSFTTVSFDPOUSPMLJUPQUJPO accessory) t &MFDUSJDIFBUJOHPQUJPOBDDFTTPSZ t 0VUEPPSBJSmMUFSPQUJPOBDDFTTPSZ t 1SPUFDUJPOHSJMMFPQUJPOBDDFTTPSZ t )PUXBUFSDPJMPQUJPOBDDFTTPSZ t &DPOPNJ[FSBDDFTTPSZ t 6TFSJOUFSGBDFPQUJPO t .JOJNVNPQFOJOHQPUFOUJPNFUFS (option/accessory) t 7PMUGSFFDPOUBDUTPQUJPO t 0QUJPOBMDPNNVOJDBUJPOTPQUJPO accessory) t 3FUVSOBJSTFOTPSPQUJPOBDDFTTPSZ t 4VQFSJPSESJWFPQUJPO t 1;GPSWFSUJDBMEJTDIBSHFPQUJPO t /JOFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOEOPNJOBM heating capacities from 15.8 to 83 kW. t 6OJUTDPOTJTUPGUXPTFDUJPOTBOJOEPPSTFDUJPO1; BOEBOPVUEPPS section (38PZ) of matching size. t *EFBMGPSJOTUBMMBUJPOJOOFXCVJMEJOHTPSSFGVSCJTINFOUQSPKFDUTGPSTNBMMBOE medium-sized commercial and residential applications, such as restaurants, shops, laboratories, art galleries, offices and homes. t $BCJOFUJTNBEFPGQSFQBJOUFENFUBMTIFFUT5IFQBOFMTBSFUIFSNBMMZBOE acoustically insulated. t %PVCMFJOMFUDFOUSJGVHBMGBOTXJUIGPSXBSEDVSWFECMBEFT t 3FGSJHFSBOUUPBJSIFBUFYDIBOHFSTNBOVGBDUVSFEGSPNIJHIRVBMJUZEFPYJEJ[FE and dehydrated copper tubing, mechanically expanded into precoated aluminium fins. t 5ISFFQIBTFSFDJQSPDBUJOHPSTDSPMMDPNQSFTTPSTGPS3$XJUICVJMUJO crankcase heaters and overcurrent and overtemperature protection. t #VJMUJOPWFSQSFTTVSFWBMWFT t 3FGSJHFSBOUDJSDVJUNBEFPGEFPYJEJ[FEBOEEFIZESBUFEDPQQFSUVCJOHDPNQMFUFMZ hermetic and leak tested. t .BTUFS-JOL**FMFDUSPOJDDPOUSPMTZTUFN Master Link II electronic control 138 50PZ (40PZ/38PZ) Physical data 50PZ 015 025 030 kW 13.42 21.81 28.50 Nominal cooling capacity* kW 15.76 25.02 30.58 Nominal heating capacity** Weight kg 50PZ 238 400 412 40PZ 78 140 150 38PZ 160 260 262 Hermetic reciprocating Scroll Compressor (R-407C) Copper tubes, pretreated aluminium fins Indoor/outdoor coil (40PZ/38PZ) Double inlet centrifugal type Indoor coil fan (40PZ) Quantity 1 2 2 Nominal air flow l/s 960 1490 1690 Double inlet centrifugal type Outdoor coil fan (38PZ) Quantity 1 2 2 Nominal air flow l/s 1470 3020 2780 * Based on an outdoor air temperature of 35°C db and an indoor air temperature of 19°C wb. ** Based on an outdoor air temperature of 6°C wb and an indoor air temperature of 20°C db. 031 27.70 30.20 040 34.36 39.15 045 43.60 50.18 055 52.51 57.43 065 61.94 66.60 075 72.58 83.06 427 150 277 638 230 408 864 297 567 919 317 602 968 335 633 1058 365 693 2 1690 2 2190 2 2640 2 2910 2 3140 2 3530 2 2780 2 3610 2 4580 2 5080 2 6030 2 6890 040 400 045 400 055 400 065 400 075 400 18.1 17.5 21.6 20.8 25.4 23.7 30.2 27.1 38.5 34.3 31.8 30.2 134.0 38.2 36.8 156.7 42.4 40.9 187.8 50.9 47.4 219.0 68.6 63.5 256.0 Electrical data 50PZ (40PZ/38PZ) 015 025 030 031 V 400 400 400 400 Nominal voltage* kW Nominal power input Cooling** 7.2 11.2 13.6 14.6 Heating*** 6.6 11.1 12.4 12.7 A Nominal current drawn Cooling** 13.7 19.2 22.2 26.6 Heating*** 13.0 19.2 20.7 24.0 A 80.0 106.3 133.3 95.3 Starting current * All units are built for 3-phase, 50 Hz supply. ** Based on an outdoor air dry bulb temperature of 35°C and an indoor air wet bulb temperature of 19°C. *** Based on an outdoor air temperature of 6°C wb and an indoor air temperature of 21°C db. Dimensions, mm 50PZ 015 025 030, 031 040 045, 055 065, 075 38PZ 015 025 030, 031 040 045, 055 065, 075 40PZ 015 025 030, 031 040 045, 055 065, 075 50PZ A 910 1350 1350 1600 2126 2526 A 910 1350 1350 1600 2126 2526 A 910 1350 1350 1600 2126 2526 Operating limits B 850 883 883 993 1154 1154 B 785 809 809 919 1080 1080 B 850 883 883 993 1154 1154 A C 1688 1890 1940 2095 2158 2158 C 1180 1280 1280 1435 1498 1498 C 588 690 740 740 750 750 Cooling Heating Zone Dry bulb Wet bulb Dry bulb Wet bulb Indoor air temperature °C Maximum 35 21 27 Minimum 19 14 Outdoor air temperature °C Maximum 46 24 18 Minimum 19* -15 * With optional head pressure control, the unit will operate at temperatures below 19°C. A 40PZ C B B A 38PZ B C C Clearances required 139 PACKAGED ROOFTOP HEAT PUMPS Air treatment 48/50 UA/UH Options/accessories Features t t t t t t t t Seven sizes with nominal cooling capacities from 44 to 109 kW and nominal heating capacities from 44 to 112 kW. t $PPMJOHPOMZPSQBDLBHFESFWFSTJCMFSPPGUPQIFBUQVNQTBWBJMBCMFXJUIBEEJUJPOBM heating options (hot-water coil or electric heaters). t 7FSTBUJMFBOEFóDJFOUIFBUQVNQTEFTJHOFEGPSPVUEPPSJOTUBMMBUJPO t 4FMGDPOUBJOFEDBOCFJOTUBMMFEJODPNNFSDJBMBOEJOEVTUSJBMBQQMJDBUJPOT t 6OJUTVTFUIFP[POFGSJFOEMZSFGSJHFSBOU3"UIBUEPFTOPUBòFDUUIFP[POF layer. t $PNQPOFOUTBSFTQFDJmDBMMZEFTJHOFEGPS3"SFGSJHFSBOU t 3FEVDFETJ[FBOEXFJHIUNBLFUIFTFVOJUTJEFBMGPSUPEBZTMJHIUXFJHIUCVJMEJOH structures. t $BCJOFUNBEFPGQPXEFSQBJOUFETIFFUNFUBM t $PNQSFTTPSTBSFIFSNFUJDTDSPMMDPNQSFTTPSTBOENPVOUFEPOWJCSBUJPOJTPMBUPST t $SBOLDBTFIFBUFSTBSFTUBOEBSEGPSBMMVOJUT t -PXOPJTFTISPVEFEBYJBM'MZJOH#JSEGBOTNBEFPGDPNQPTJUFQMBTUJDNBUFSJBM t )FBUFYDIBOHFSTNBEFPGIJHIRVBMJUZTUBHHFSFEDPQQFSUVCJOHNFDIBOJDBMMZ bonded into pre-coated corrugated aluminium fins. t -FBLUJHIUSFGSJHFSBOUDJSDVJUTXJUICSB[FEDPOOFDUJPOTBOESFEVDFEWJCSBUJPOMFWFMT Access to pressure transducers and temperature sensors without losing charge. t 6OJUTBSFGVMMZXJSFEJOBDDPSEBODFXJUI&/TUBOEBSET t 4JNQMJmFEFMFDUSJDBMDPOOFDUJPOT t 3FEVDFEEFGSPTUDZDMFEVSBUJPOEVFUPUIFOFXDPJMEFTJHOBOEBOBVUPBEBQUJWF control algorithm. t )JHIQBSUMPBEFóDJFODJFTBOEFBTZDPNNJTTJPOJOHXJUI7BSJBCMF"JS7PMVNFTVQQMZ fan option. t t t t t t t t t t t t t t t t t t t t &MFDUSJDIFBUFSTWBSJPVTDBQBDJUJFT )PUXBUFSDPJMTWBSJPVTDBQBDJUJFT 7BSJPVTDPJMQSPUFDUJPOPQUJPOT Gaz burner, various capacitie 'SFTIBJSTMJEJOHQBOFM .BOVBMPVUEPPSBJSEBNQFS &DPOPNJ[FSUIFSNPTUBUJDPSFOUIBMQZ control, with or without CO2 sensor control* 4VQQMZGBOXJUIWBSJPVTIJHITUBUJD pressure options with or without soft starter* 7BSJBCMF"JS7PMVNFTVQQMZGBO 7BSJPVTmMUFSPQUJPOT 4UBJOMFTTTUFFMESBJOQBO &OFSHZSFDPWFSZNPEVMF 7BSJPVTSFUVSOFYIBVTUBJSPQUJPOT 7BSJPVTUFNQFSBUVSFTFOTPSPQUJPOT $$/+#VT-POPS#"$OFUHBUFXBZT %JSUZmMUFSEFUFDUJPO 4VQQMZBJSnPXEFUFDUJPO 4NPLFEFUFDUPS 'JSFUIFSNPTUBU %VDUDPOOFDUJPOmYJOHGSBNF 7BSJPVTQBDLBHJOHPQUJPOT 7FSUJDBMTVQQMZSPPGDVSC 7FSUJDBMTVQQMZSPPGDVSCXJUI longitudinal adjustment** 7FSUJDBMTVQQMZSPPGDVSCXJUI transversal adjustment** )PSJ[POUBMTVQQMZSPPGDVSC 5SBOTJUJPOSPPGDVSC'SFODI&31 3FNPUFVTFSJOUFSGBDF1SP%JBMPH * Option ** Accessory \\MAINMENU\STATUS CAPB_T DEM_LIM SP CTRL_PNT EMSTOP 0 100 4.2 -28.9 dsable % % °C °C Circuit B Total Capacity START/STOP ENTER PRO-DIALOG+ Pro-Dialog+ operator interface 140 48/50 UA/UH Physical and Electrical data 48/50UA Eurovent Performances @ EN14511-2011 Nominal cooling capacity* Nominal power input EER Eurovent Energy class Cooling Eurovent Performances @ EN14511-2013 Nominal cooling capacity* Nominal power input EER Eurovent Energy class Cooling 48/50UH Eurovent Performances @ EN14511-2011 Cooling Nominal cooling capacity* Nominal power input EER* Eurovent Energy class Cooling Heating Nominal heating capacity** Nominal power input COP** Eurovent Energy class Heating Eurovent Performances @ EN14511-2013 Cooling Nominal cooling capacity* Nominal power input EER* 045 055 065 075 085 100 120 kW kW 44.1 14.4 3.06 A 50.9 17.9 2.85 B 61.1 21.2 2.88 B 71.5 27.0 2.65 C 88.9 28.7 3.10 A 102.5 34.1 3.01 A 114.5 40.3 2.84 B kW kW 43.6 15.1 2.89 B 045 50.7 19.4 2.61 C 055 61.1 22.5 2.71 C 065 71.6 28.9 2.48 D 075 88.4 30.8 2.87 B 085 101.4 37.0 2.74 C 100 112.1 42.0 2.67 C 120 kW kW 43.5 14.4 3.03 A 50.1 17.7 2.83 B 59.1 20.7 2.86 B 69.1 26.5 2.61 C 84.5 27.5 3.07 A 96.7 33.8 2.86 B 108.8 38.7 2.81 B kW kW 43.5 13.2 3.30 B 54.4 16.0 3.41 A 62.0 20.1 3.09 C 74.5 24.8 3.01 C 85.1 24.4 3.49 A 98.7 30.7 3.21 B 120.7 37.5 3.22 B unit, equipped with a high49.4 18.9 2.61 58.4 22.0 2.65 67.7 28.0 2.42 83.1 29.6 2.81 95.5 36.2 2.64 106.1 40.7 2.61 Eurovent Energy class Cooling Heating B C C D B C C Nominal heating capacity** kW Nominal power input kW COP** Eurovent Energy class Heating Electric Heaters (only 50 series) Type Heating capacity kW Capacity steps Rated Amps Gaz Burners (only 48 series) Natural gas heating type Net heat input (min./max.) kW Heat output (min./max.) kW Number Stages Propane gas heating type Net heat input (min./max.) kW Heat output (min./max.) kW Number Stages Weight †† kg Power input (400 V-3 ph-50 Hz)** kW Gas connection pipe size in Control Refrigeration System # Circuits / # Comp. / Type Outdoor fan / motor Outdoor fan noise power level dB(A) 48/50 UA/UH Indoor fix speed fans and motors (STD, HS1, HS2, HS3) Nominal Air flow m3/h Minimum Static pressure available *** Pa Maximum Static pressure available *** Pa Indoor variable speed fan and motor (VAV) Nominal Air flow m3/h Static pressure available *** Pa Maximum Static pressure available *** Pa Operating weight 50UH weight (without options) kg 48UH weight (without options) kg General Main Dimensions Length mm Width mm Height mm 44.9 13.9 3.24 B 57.2 17.0 3.36 B 64.2 21.2 3.03 C 77.2 26.9 2.87 D 89.0 27.0 3.30 B 101.8 33.7 3.02 C 125.7 40.0 3.14 C OPT 84 27 18 - 9 39 OPT 85 36 18 - 18 52 OPT 85 36 18 - 18 52 OPT 85 36 18 - 18 52 OPT 86 54 27 - 54 78 OPT 86 54 27 - 54 78 OPT 86 54 27 - 54 78 OPT 91 49/70 42/62 2 OPT 101 --/71 --/64 1 73 0.22 Rp 3/4» F ProDialog+ OPT 91 49/70 42/62 2 OPT 101 --/71 --/64 1 73 0.22 Rp 3/4» F ProDialog+ OPT 92 57/81 50/73 2 OPT 102 --/83 --/75 1 80 0.22 Rp 3/4» F ProDialog+ OPT 92 57/81 50/73 2 OPT 102 --/83 --/75 1 80 0.22 Rp 3/4» F ProDialog+ OPT 94 49/139 43/125 3 OPT 104 71/142 64/128 2 150 0.44 Rp 3/4» F ProDialog+ OPT 94 49/139 43/125 3 OPT 104 71/142 64/128 2 150 0.44 Rp 3/4» F ProDialog+ OPT 95 57/162 51/147 3 OPT 105 83/166 75/151 2 165 0.44 Rp 3/4» F ProDialog+ 1 / 1 / Scroll 1 / 2 / Scroll 2 / 2 / Scroll 2 / 2 / Scroll 2 / 2 / Scroll 2 / 3 / Scroll 2 / 4 / Scroll 86.5 045 84.4 055 90.6 065 90.6 075 90.7 085 91.0 100 91.3 120 9000 150 585 12500 140 680 12500 225 700 14200 120 580 20000 225 675 20000 225 675 20000 225 675 9100 50 500 12400 50 600 12500 50 620 14200 50 660 17730 50 535 18975 50 535 19980 50 640 kW kW efficiency Eurovent-certified air-to-air heat recovery wheel with 63% to 88% efficiency, an integrated variable-air-volume plug fan and a control system for plug-and-play installation. Specially designed for economical indoor air extraction and to take in fresh air to meet current and future requirements for high-energy-efficiency buildings. t6OJUDBCJOFUJTNBEF of galvanised and powder-painted sheet metal. t'JUUFEXJUI(mMUFSTPO the fresh-air side as standard to protect the heat recovery wheel against dust. t*OTVMBUFEEVDUQPXFS and control wiring between ERM and rooftop unit - supplied by the factory with the duct kit. t)FBUFYDIBOHFSSFDMBJNTVQ to 90% of the heat from the extract air and transfers it to the supply air. t)JHIFóDJFODZQMVH fans for exhaust air are more energy-efficient 755 820 900 965 970 1043 980 1053 1430 1565 1520 1655 1610 1775 2120 2189 1386 2120 2189 1431 2120 2189 1792 2120 2189 1792 3577 2193 1822 3577 2193 1822 3577 2193 1822 and require less maintenance. Nominal Eurovent conditions: Outdoor air dry bulb temperature of 35°C, indoor air wet bulb temperature of 19°C. Nominal Eurovent conditions: Outdoor air wet bulb temperature of 6°C, indoor air dry bulb temperature of 20°C. For standard unit at nominal air flow without options Weight and power input values are valid for the heating modules. 48/50 UA/UH† Power circuit Nominal power supply Voltage range Control circuit supply Maximum start-up current* Unit power factor at maximum capacity** Maximum unit power input** Nominal unit current draw*** Maximum unit current draw**** Customer-side unit power reserve * ** *** **** † The energy recovery module (ERM) is an individual dual-flow 43.4 15.0 2.89 * ** *** †† Energy recovery module (option) 045 055 065 V-ph-Hz 400-3-50 V 360-440 24 V, via internal transformer A 206 173 183 0.82 0.81 0.81 kW 21.68 27.41 33.52 A 28.73 36.76 43.00 A 38.20 49.10 60.10 kW Customer reserve at the 24 V control power circuit 075 085 100 120 204 0.84 40.50 52.12 69.80 246 0.84 44.58 55.97 77.00 261 0.83 52.98 66.55 92.20 226 0.83 59.38 77.79 103.10 Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Power input, compressors and fans, at the their operating limits and nominal voltage of 400 V (data given on the unit nameplate). Standardised Eurovent conditions: indoor air wet bulb 19°C, outside air temperature 35°C with standard fan performance Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Standard unit (without any options and accessories) 141 Industrial Index System architecture 142 Index Type Water-cooled chillers With centrifugal compressors Absorption chillers Single-effect Hot water-fired absorption chillers Steam-fired absorption chillers Double-effect Steam-fired absorption chillers Direct-fired absorption chillers/heaters Range Refrigerant Cooling capacity, kW Heating capacity, kW Page 19XR/XRV R-134a 1000-5300 - 144 16LJ 16TJ 264-1846 352-2461 - 146 148 16NK 16DJ 345-4652 352-5274 268-4026 150 152 Application of the new EN14511 : 2013 chiller and heat pump performance standard: Chiller and heat pump performances are calculated in accordance with the EN14511 : 2013 calculation standard and certified by Eurovent. The latest version of EN14511 uses a different method to take into account the contribution of water pumps, or heat exchanger pressure drops in the unit performances. The efficiency of the pump is no longer a default value, but a function of the required hydraulic power. In January 2012, the Eurovent Certification Company decided that this method is more realistic and it is fully applied starting from the 2012 certification campaign. The performances declared based on the new version of the standard were published on the ECC website www.eurovent-certification.com at the end of March 2012. IMPORTANT: Only 2012 performances rated according the new EN14511 : 2013, taking in account water pump and heat exchanger pressure drop are certified by Eurovent. For units declared before 2012, the previous gross EER and COP values without pump correction (for units with integral pump - measured with the pump not running) and the corresponding energy classes are available on ECC website. Application rating conditions Air-cooled cooling Water-cooled cooling Air conditioning applications (AC) Evaporator EWT/LWT 12°C/7°C OAT 35°C Evaporator EWT/LWT 12°C/7°C Condenser EWT/LWT 30°C/35°C Medium brine applications (MB) Evaporator EWT/LWT 0°C/-5°C OAT 35°C Evaporator EWT/LWT 0°C/-5°C Condenser EWT/LWT 30°C/35°C Legend EWT Entering water temperature LWT Leaving water temperature OAT Outdoor air temperature 143 CENTRIFUGAL LIQUID CHILLERS Industrial 19XR/XRV Options/accessories Features t 5XPUZQFTPGVOJUNPVOUFEWBSJBCMF frequency drives (VFDs): standard and high tier, to match different customer requirements in terms of cost and electrical performances t 3FGSJHFSBOUJTPMBUJPOWBMWFTBMMPX the refrigerant to be stored inside the chiller during service t 1VNQEPXOVOJUDPNCJOFEXJUI the refrigerant isolation valves, eliminates complex connections to portable transfer systems t 6OJUNPVOUFETUBSUFSSFEVDFT machine installation time and expense t )JHIWPMUBHFNPUPSTBWBJMBCMF V, 3300 V, 6300 V t $$/+#VTSFNPUFDPOOFDUJPO t CBSXBUFSIFBUFYDIBOHFS t /P[[MFXJUInBOHFTXBUFSJOMFU outlet with flanges) t %FMJWFSFEJOGPVSTFDUJPOTUP facilitate the installation t /PNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t .JYNBUDIDBQBCJMJUJFToBDPNQMFUFMJOFPGDPNQSFTTPSTBOEIFBUFYDIBOHFST to ensure the optimal combination of machine components regardless of capacity, lift and efficiency specifications. t )FSNFUJDDPNQSFTTPSoFMJNJOBUJPOPGMFBLSJTLTGSPNUIFDPNQSFTTPSNPUPS shaft sealing in an open compressor. t 4JOHMFTUBHFDPNQSFTTPSXJUITQFDJBMGFBUVSFToBFSPEZOBNJDBMMZDPOUPVSFE impellers, variable inlet guide vanes and movable diffusers for better product reliability and compressor part and full-load operating efficiency. t 7BSJBCMFTQFFEDPNQSFTTPSDBQBCJMJUZoJNQSPWFNFOUPGQBSUMPBEFóDJFODZ and electrical performance. t )FBUFYDIBOHFSTDFSUJmFECZUIF&VSPQFBOQSFTTVSFWFTTFMTDPEF1&% t $BSSJFSOVNFSJDBMQSPEVDUJOUFHSBUFEDPOUSPMPòFSTVONBUDIFEnFYJCJMJUZBOE functionality. Each unit integrates directly with the Carrier Comfort Network (CCN), providing a system solution to controls applications. Numerical control 144 19XR/XRV Physical data Nominal capacity, kW Heat exchanger size 3 4 5 6 7 8 With two-pass nozzle-in-head water boxes. Maximum height 19XR/XRV 1000-5300 * ** Dimensions, mm Length* - Standard 4230 4230 4230 4230 4919 4919 Average operating weight, kg Length* - Extended 4754 4754 4754 4754 5525 5525 Width (excl. 19XRV) 1670 1880 2054 2124 2530 2530 Height** 2127 2294 2781 2879 3276 3343 8000 10204 12698 15420 17765 25712 19XR refrigeration cycle Flasc chamber Condenser water Condenser Float valve chamber Condenser isolation valve (optional) Transmission Motor Diffuser Filter drier Guide vane motor Stator Rotor Orifice Refrigerant liquid Oil filter Oil pump Guide vanes Impeller Oil cooling Compressor Thermal expansion valve (TXV) Back pressure orifice Refrigerant vapour Refrigerant liquid/vapour Chilled water Cooler Distribution pipe Cooler isolation valve (optional) 145 SINGLE-EFFECT HOT WATERFIRED ABSORPTION CHILLERS Industrial SUPER ABSORPTION Display and control board Features 6 1 2 STOP RUN CHILLER / HEATER #1ABS PUMP #2ABS PUMP REF PUMP 7 SET BACK PURGE PUMP 8 9 REMOTE DILUTION SAFETY CIRCUIT 10 4 STAND BY CHILLER ALARM BUZZER STOP STOP LOCAL OPERATION RUN POWER 5 3 1 2 3 4 5 6 7 8 9 10 Operation indication Stop indication Alarm indication Remote/local select button Operation mode selection Data display Stand-by indication Dilution indication Safety circuit indication Power indication 16LJ t 5XFOUZPOFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t %FTJHOFEUPQSPWJEFDIJMMFEXBUFSGSPNXBTUFIFBUTPVSDFTHFOFSBUFEGSPN industrial processes and cogeneration systems. t "MMPXTEJWFSTJmDBUJPOPGDSJUJDBMDPPMJOHSFRVJSFNFOUT$SJUJDBMDPPMJOHMPBET are met with minimal electrical power input taking advantage of hot water sources available on site. t "MMPXTVTFPGTNBMMFSFNFSHFODZHFOFSBUPSTTJODFUIFFMFDUSJDBMMPBEBTTPDJBUFE with an absorption chiller is minimal, compared to an electrically driven chiller. t $PPMJOHSFRVJSFNFOUTBSFNFUXJUIPVUVTFPGSFGSJHFSBOUT t .JOJNJTFTHMPCBMXBSNJOHFòFDUCZHSFBUMZSFEVDJOHQPXFSDPOTVNQUJPOBOE eliminating the generation of greenhouse gases. t 3FEVDFEOPJTFBOEWJCSBUJPOMFWFMT5IFBCTPSQUJPODIJMMFSEPFTOPUVTFBMBSHF motor-compressor, leading to quiet, trouble-free operation. t 4NBMMGPPUQSJOU5IFIJHIFóDJFODZBTTPDJBUFEXJUIUIFTFDIJMMFSTSFTVMUTJOB reduction of the required installation space. t "VUPEJBHOPTJTTZTUFNNPOJUPSTPQFSBUJOHDPOEJUJPOTQSFEJDUTDIJMMFSJOGPSNBUJPO and maintains stable operation. t "EWBODFEIJHIQSFDJTJPODPOUSPMTZTUFN t "CTPSQUJPOQVNQXJUIJOWFSUFSDPOUSPMPQUJPO GPSFOFSHZTBWJOHPQFSBUJPO t )JHIQFSGPSNBODFQVSHFTZTUFNNBJOUBJOTVOJUQFSGPSNBODFBOENJOJNJTFT maintenance requirements. t 4UBUFPGUIFBSUQSPUFDUJPOEFWJDFTHVBSBOUFFFOIBODFEPQFSBUJOHTBGFUZ 146 16LJ Physical data 16LJ Cooling capacity Chilled water system* Flow rate Pressure drop Connection (ANSI) Retention volume Cooling water system** Flow rate Pressure drop Connection (ANSI) Retention volume Hot water system*** Flow rate Pressure drop Connection (ANSI) Retention volume Dimensions Length A Height B Width C Operating weight Power supply Total current drawn 16LJ Cooling capacity Chilled water system* Flow rate Pressure drop Connection (ANSI) Retention volume Cooling water system** Flow rate Pressure drop Connection (ANSI) Retention volume Hot water system*** Flow rate Pressure drop Connection (ANSI) Retention volume Dimensions Length A Height B Width C Operating weight Power supply Total current drawn kW 01 88 02 140 03 176 11 264 12 316 13 387 14 475 21 545 22 633 23 738 24 844 l/s kPa in m3 3.50 71 2 - 5.61 60 2-1/2 - 7.00 59 2-1/2 - 11.40 56 3 0.11 13.60 61 3 0.13 16.70 36 4 0.15 20.40 40 4 0.17 23.50 35 5 0.22 27.30 38 5 0.25 31.80 74 5 0.28 36.30 77 5 0.30 l/s kPa in m3 10.10 77 3 - 16.20 48 4 - 20.20 49 4 - 17.00 38 5 0.33 20.40 39 5 0.37 25.00 67 5 0.40 30.70 72 5 0.45 35.20 68 6 0.58 40.90 71 6 0.63 47.70 42 8 0.69 54.40 45 8 0.76 l/s kPa in m3 mm 3.06 52 2 - 4.89 31 2-1/2 - 6.11 36 2-1/2 - 10.40 31 4 0.11 12.50 12 4 0.12 15.20 29 4 0.14 18.70 32 4 0.16 21.50 31 5 0.20 24.90 37 5 0.22 29.00 30 6 0.25 33.00 31 6 0.28 kg V-ph-Hz A 1745 2115 1255 2070 2450 2115 1255 2680 2450 2115 1435 3150 2740 2200 1400 4400 3750 2200 1400 5400 3750 2200 1400 5600 3850 2350 1560 6800 3850 2350 1560 7300 4870 2370 1560 8300 4870 2370 1560 8900 4.8 4.8 4.8 2740 2200 1400 4200 400-3-50 6.1 6.1 6.1 6.1 8.8 8.8 8.9 8.9 kW 31 949 32 1055 41 1178 42 1319 51 1477 52 1653 53 1846 63 2637 72 3165 82 3956 l/s kPa in m3 40.80 75 6 0.35 45.60 78 6 0.38 50.80 74 8 0.49 56.70 64 8 0.56 63.60 54 8 0.70 71.10 73 8 0.77 79.40 96 8 0.83 114 46 10 1.21 136 105 12 1.53 170 46 14 1.94 l/s kPa in m3 61.40 36 8 0.98 68.10 37 8 1.05 76.10 38 10 1.31 85.30 40 10 1.41 95.30 92 12 1.97 107 86 12 2.13 119 45 12 2.27 170 58 14 3.24 205 44 16 4.10 256 68 16 5.11 l/s kPa in m3 mm 37.00 30 6 0.33 42.00 30 6 0.36 46.00 30 8 0.44 52.00 30 8 0.48 58.00 28 8 0.56 65.00 38 8 0.61 73.00 50 8 0.66 94.40 19 10 1.08 113 19 10 1.27 142 25 10 1.55 4920 2610 1630 10700 4920 2610 1630 11300 5070 2860 1700 13100 5210 3210 1990 18500 5750 3210 1990 20000 6250 3210 1990 21400 6750 3660 2420 31100 6990 3780 2650 39100 7590 3990 2820 46600 10.90 10.90 10.90 5070 2860 1700 13600 400-3-50 10.90 10.90 10.90 10.90 30.20 37.50 39.60 kg V-ph-Hz A * Sizes 01/02/03: 12.0/6.0°C; all other sizes 12.2/6.7°C (Fooling factor = 0.018 m2 K/kW) ** Sizes 01/02/03: 29.0/34.0°C; all other sizes 29.4/38.4°C (Fooling factor = 0.044 m2 K/kW) *** Sizes 01/02/03: 90.0/80.0°C; all other sizes 95.0/86.0°C (Fooling factort = 0.018 m2 K/kW) C A B 147 SINGLE-EFFECT STEAM-FIRED ABSORPTION CHILLERS Industrial SUPER ABSORPTION Display and control board Features 6 1 2 STOP RUN CHILLER / HEATER #1ABS PUMP #2ABS PUMP REF PUMP 7 SET BACK PURGE PUMP 8 9 REMOTE SAFETY CIRCUIT 10 4 STAND BY DILUTION CHILLER ALARM BUZZER STOP STOP LOCAL OPERATION RUN POWER 5 3 1 2 3 4 5 6 7 8 9 10 Operation indication Stop indication Alarm indication Remote/local select button Operation mode selection Data display Stand-by indication Dilution indication Safety circuit indication Power indication 16TJ t 'JGUFFOTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t %FTJHOFEGPSDPPMJOHBQQMJDBUJPOTXIFSFMPXQSFTTVSFTUFBNJTBWBJMBCMFBT waste heat. t $BOUJFJOUPEJTUSJDUTUFBNTZTUFNT t "MMPXTEJWFSTJmDBUJPOPGDSJUJDBMDPPMJOHSFRVJSFNFOUT$SJUJDBMDPPMJOHMPBET are met with minimal electrical power input taking advantage of steam sources available on site. t "MMPXTVTFPGTNBMMFSFNFSHFODZHFOFSBUPSTTJODFUIFFMFDUSJDBMMPBEBTTPDJBUFE with an absorption chiller is minimal, compared to an electrically driven chiller. t $PPMJOHSFRVJSFNFOUTBSFNFUXJUIPVUVTFPGSFGSJHFSBOUT t .JOJNJTFTHMPCBMXBSNJOHFòFDUCZHSFBUMZSFEVDJOHQPXFSDPOTVNQUJPOBOE eliminating the generation of greenhouse gases. t 3FEVDFEOPJTFBOEWJCSBUJPOMFWFMT5IFBCTPSQUJPODIJMMFSEPFTOPUVTFBMBSHF motor-compressor, leading to quiet, trouble-free operation. t 4NBMMGPPUQSJOU5IFIJHIFóDJFODZBTTPDJBUFEXJUIUIFTFDIJMMFSTSFTVMUTJOB reduction of the required installation space. t "VUPEJBHOPTJTTZTUFNNPOJUPSTPQFSBUJOHDPOEJUJPOTQSFEJDUTDIJMMFSJOGPSNBUJPO and maintains stable operation. t "EWBODFEIJHIQSFDJTJPODPOUSPMTZTUFN t "CTPSQUJPOQVNQXJUIJOWFSUFSDPOUSPMPQUJPO GPSFOFSHZTBWJOHPQFSBUJPO t )JHIQFSGPSNBODFQVSHFTZTUFNNBJOUBJOTVOJUQFSGPSNBODFBOENJOJNJTFT maintenance requirements. t 4UBUFPGUIFBSUQSPUFDUJPOEFWJDFTHVBSBOUFFFOIBODFEPQFSBUJOHTBGFUZ 148 16TJ Physical data 16TJ Cooling capacity Chilled water system* Flow rate Pressure drop Connection (ANSI) Retention volume Cooling water system** Flow rate Pressure drop Connection (ANSI) Retention volume Steam system Consumption Dimensions Length A Height B Width C Operating weight Power supply Total current drawn kW 11 352 12 422 13 527 14 633 21 738 22 844 23 985 24 1125 l/s kPa in m3 15.10 50 4 0.12 18.20 51 4 0.13 22.70 64 4 0.15 27.30 67 4 0.17 31.70 60 5 0.22 36.40 64 5 0.25 42.50 42 6 0.29 48.30 45 6 0.31 l/s kPa in m3 22.70 27.30 34 37 5 5 0.33 0.37 Saturated steam 100 kPa 780 940 34.20 32 5 0.41 40.80 36 5 0.45 47.80 32 6 0.58 54.40 35 6 0.63 63.60 65 8 0.69 72.80 70 8 0.76 1170 1410 1640 1880 2190 2500 2690 2200 1400 4000 400-3-50 6.1 2690 2200 1400 4300 3690 2200 1400 5100 3690 2200 1400 5400 3790 2350 1560 6700 3790 2350 1560 6900 4850 2370 1560 7900 4850 2370 1560 8300 6.1 6.1 6.1 8.8 8.8 8.9 8.9 41 1582 42 1758 51 1969 52 2215 53 2461 68.10 44 8 0.49 75.80 39 8 0.56 84.70 35 8 0.70 95.30 47 8 0.77 106.10 61 8 0.83 102.20 59 10 1.31 113.60 63 10 1.41 127.20 39 12 1.98 143.10 52 12 2.13 158.90 68 12 2.28 3510 3900 4370 4920 5460 4990 2860 1700 12500 4990 2860 1700 12800 5060 3210 1990 17500 5600 3210 1990 18900 6100 3210 1990 20200 10.90 10.90 10.90 10.90 10.90 kg/h mm mm mm mm kg V-ph-Hz A 16TJ 31 32 kW 1266 1407 Cooling capacity Chilled water system* Flow rate l/s 54.40 60.60 Pressure drop kPa 48 51 Connection (ANSI) in 6 6 0.35 0.38 Retention volume m3 Cooling water system** Flow rate l/s 81.70 90.80 Pressure drop kPa 54 57 Connection (ANSI) in 8 8 0.98 1.05 Retention volume m3 Saturated steam 100 kPa Steam system Consumption kg/h 2810 3120 mm Dimensions Length A mm 4940 4940 Height B mm 2610 2610 Width C mm 1630 1630 kg 10300 10600 Operating weight V-ph-Hz 400-3-50 Power supply Total current drawn A 10.90 10.90 * 12.2 —>6.7°C (fouling factor = 0.0176 m2 K/kW) ** 29.4 —>38.4°C (fouling factor = 0.044 m2 K/kW) C A B 149 DOUBLE-EFFECT STEAM-FIRED ABSORPTION CHILLERS Industrial SUPER ABSORPTION Display and control board Features 8 1 2 STOP RUN CHILLER / HEATER 5 #1ABS PUMP #2ABS PUMP REF PUMP 9 10 11 BACK PURGE PUMP BURNER STAND BY COOLING DILUTION HEATING SAFETY CIRCUIT 12 SET REMOTE BUZZER STOP CHILLER/HEATER AL ARM BURNER ALARM STOP 6 LOCAL COMBUSTION OPERATION RUN POWER 4 7 3 1 2 3 4 5 6 7 8 9 10 11 12 Operation indication Stop indication Alarm indication Combustion indication Cooling/heating indication Remote/local select button Operation mode selection Data display Stand-by indication Dilution indication Safety circuit indication Power indication 16NK t &JHIUFFOTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8 t 5IF/,BCTPSQUJPODIJMMFSTBSFEFTJHOFEGPSDPPMJOHBQQMJDBUJPOTXIFSF low-pressure steam is available as waste heat. t $BOUJFJOUPEJTUSJDUTUFBNTZTUFNT t "MMPXTEJWFSTJmDBUJPOPGDSJUJDBMDPPMJOHSFRVJSFNFOUT$SJUJDBMDPPMJOHMPBET are met with minimal electrical power input. t "MMPXTVTFPGTNBMMFSFNFSHFODZHFOFSBUPSTTJODFUIFFMFDUSJDBMMPBEBTTPDJBUFE with an absorption chiller is minimal. t 0[POFGSJFOEMZBOE$'$GSFF t .JOJNJTFTHMPCBMXBSNJOHFòFDUCZHSFBUMZSFEVDJOHQPXFSDPOTVNQUJPOBOE eliminating the generation of greenhouse gases. t 3FEVDFEOPJTFBOEWJCSBUJPOMFWFMT5IFBCTPSQUJPODIJMMFSEPFTOPUVTFBMBSHF motor-compressor, leading to quiet, vibration-free operation. t 4NBMMGPPUQSJOU5IFIJHIFóDJFODZBTTPDJBUFEXJUIEPVCMFFòFDUDIJMMFST results in a reduction of the required installation space. t "VUPEJBHOPTJTTZTUFNNPOJUPSTPQFSBUJOHDPOEJUJPOTQSFEJDUTDIJMMFSJOGPSNBUJPO and maintains stable operation. t "EWBODFEIJHIQSFDJTJPODPOUSPMTZTUFN t "CTPSQUJPOQVNQXJUIJOWFSUFSDPOUSPMGPSFóDJFOUFOFSHZTBWJOHPQFSBUJPO t )JHIQFSGPSNBODFQVSHFTZTUFNNJOJNJTFTNBJOUFOBODFSFRVJSFNFOUT t 4UBUFPGUIFBSUQSPUFDUJPOEFWJDFTHVBSBOUFFFOIBODFEPQFSBUJOHTBGFUZ 150 16NK Physical data 16NK Cooling capacity Chilled water system* Flow rate Pressure drop Connection (ANSI) Retention volume Cooling water system* Flow rate Pressure drop Connection (ANSI) Retention volume Steam system Consumption Dimensions Length A Height B Width C Operating weight Power supply Total current drawn kW 11 345 12 447 13 549 21 689 22 861 31 1034 32 1238 41 1378 42 1551 l/s kPa in m3 14.8 44 4 0.13 19.2 64 4 0.15 23.6 64 4 0.17 29.7 57 5 0.24 37.2 42 6 0.28 44.4 41 6 0.34 53.3 49 6 0.36 59.4 46 8 0.46 66.7 41 8 0.48 l/s kPa in m3 24.7 31.9 68 40 5 5 0.34 0.38 Saturated steam 784 kPa 400 510 39.4 49 5 0.42 49.4 109 6 0.58 61.9 74 8 0.63 74.2 53 8 0.89 88.9 65 8 0.95 98.9 67 10 1.11 111.4 73 10 1.90 630 790 980 1180 1410 1570 1770 2810 2200 2050 4600 400-3-50 10.8 3850 2200 1910 5800 3850 2200 1910 6100 3880 2250 2240 7500 4920 2250 2070 8800 5040 2390 2170 11200 5040 2390 2170 11800 5100 2600 2400 13900 5100 2600 2400 14500 10.8 10.8 13.3 13.3 13.6 13.6 20.7 20.7 53 2170 61 2412 62 2757 63 3101 71 3446 72 3963 81 4652 93.9 61 8 0.77 103.9 123 10 0.99 118.6 83 10 1.06 133.6 78 10 1.13 148.3 54 12 1.41 170.6 81 12 1.61 200.3 84 14 1.94 155.6 94 12 2.14 173.1 61 14 2.79 197.8 83 14 2.97 222.5 111 14 3.15 247.2 77 16 3.67 284.4 113 16 4.11 333.9 122 16 4.76 2470 2750 3140 3530 3920 4510 5300 6370 2900 2800 22300 6100 3330 2970 26500 6190 3330 3000 30000 6710 3330 3000 32100 6440 3450 3300 38000 7460 3450 3300 42300 7460 3650 3500 47300 24.5 25.5 25.0 25.0 33.5 33.5 33.5 kg/h mm kg V-ph-Hz A 16NK 51 52 kW 1723 1927 Cooling capacity Chilled water system* Flow rate l/s 74.2 83.1 Pressure drop kPa 98 46 Connection (ANSI) in 8 8 0.65 0.71 Retention volume m3 Cooling water system** Flow rate l/s 123.6 138.3 Pressure drop kPa 53 71 Connection (ANSI) in 12 12 1.87 2.01 Retention volume m3 Saturated steam 784 kPa Steam system Consumption kg/h 1960 2200 mm Dimensions Length A 5330 5870 Height B 2900 2900 Width C 2770 2800 kg 18800 20800 Operating weight V-ph-Hz 400-3-50 Power supply Total current drawn A 22.7 24.5 Cooling per ARI 560 2000: * 12.2 —> 6.7°C (fouling factor = 0.0176 m2 K/kW) ** 29.4 —> 35.4°C (fouling factor = 0.044 m2 K/kW) B A C 151 DIRECT-FIRED DOUBLE-EFFECT ABSORPTION CHILLERS/HEATERS Industrial SUPER ABSORPTION Display and control board Features 8 1 2 STOP RUN CHILLER / HEATER 5 #1ABS PUMP #2ABS PUMP REF PUMP 9 10 11 BACK PURGE PUMP BURNER STAND BY COOLING DILUTION HEATING SAFETY CIRCUIT 12 SET REMOTE BUZZER STOP CHILLER/HEATER AL ARM BURNER ALARM STOP 6 LOCAL COMBUSTION OPERATION RUN POWER 4 7 3 1 2 3 4 5 6 7 8 9 10 11 12 Operation indication Stop indication Alarm indication Combustion indication Cooling/heating indication Remote/local select button Operation mode selection Data display Stand-by indication Dilution indication Safety circuit indication Power indication 16DJ t 5XFOUZUISFFTJ[FTXJUIOPNJOBMDPPMJOHDBQBDJUJFTGSPNUPL8BOE heating capacities from 268 to 4026 kW. t 5IF%+BCTPSQUJPODIJMMFSTIFBUFSTPòFSCVJMEJOHPXOFSTBCFUUFSTPMVUJPOGPS many new and retrofit applications. Installation of a direct-fired chiller/heater eliminates the need for a boiler, reducing the initial cost of the system. t &YDFMMFOUGPSQFBLTIBWJOHEVSJOHIJHIFMFDUSJDBMEFNBOEQFSJPET t "MMPXTEJWFSTJmDBUJPOPGDSJUJDBMDPPMJOHSFRVJSFNFOUT$SJUJDBMMPBETBSFNFU with minimal electrical power input. t "MMPXTVTFPGTNBMMFSFNFSHFODZHFOFSBUPSTTJODFUIFFMFDUSJDBMMPBEBTTPDJBUFE with an absorption chiller is minimal. t 0[POFGSJFOEMZBOE$'$GSFF t .JOJNJTFTHMPCBMXBSNJOHFòFDUCZHSFBUMZSFEVDJOHQPXFSDPOTVNQUJPO t 3FEVDFEOPJTFBOEWJCSBUJPOMFWFMT5IFBCTPSQUJPODIJMMFSEPFTOPUVTFBMBSHF motor-compressor, leading to quiet, vibration-free operation. t 4NBMMGPPUQSJOU5IFIJHIFóDJFODZBTTPDJBUFEXJUIEPVCMFFòFDUDIJMMFST results in reducing the required installation space. t "VUPEJBHOPTJTTZTUFNNPOJUPSTPQFSBUJOHDPOEJUJPOTQSFEJDUTDIJMMFSJOGPSNBUJPO and maintains stable operation. t "EWBODFEIJHIQSFDJTJPODPOUSPMTZTUFN t "CTPSQUJPOQVNQXJUIJOWFSUFSDPOUSPMGPSFóDJFOUFOFSHZTBWJOHPQFSBUJPO t )JHIQFSGPSNBODFQVSHFTZTUFNNJOJNJTFTNBJOUFOBODFSFRVJSFNFOUT t 4UBUFPGUIFBSUQSPUFDUJPOEFWJDFTHVBSBOUFFFOIBODFEPQFSBUJOHTBGFUZ 152 16DJ Physical data 16DJ Cooling capacity Heating capacity Chilled/hot-water system* Flow rate Pressure drop Connection (ANSI) Retention volume Cooling water system* Flow rate Pressure drop Connection (ANSI) Retention volume Fuel type Consumption (cooling/heating)** Dimensions Length A Height B Width C Operating weight Power supply Total current drawn kW kW 11 352 268 12 422 322 13 527 403 14 633 483 21 738 564 22 844 644 23 985 751 24 1125 859 31 1266 966 32 1407 1074 41 1582 1208 42 1758 1342 l/s kPa in m3 15.1 70 4 0.12 18.2 71 4 0.13 22.7 90 4 0.15 27.3 94 4 0.17 31.8 85 5 0.22 36.3 89 5 0.24 42.4 61 6 0.28 48.4 65 6 0.30 54.5 69 6 0.34 60.6 72 6 0.36 68.1 62 8 0.46 75.7 65 8 0.48 l/s kPa in m3 25.2 33 5 0.31 Natural gas 320 30.3 36 5 0.34 37.9 50 5 0.38 45.4 56 5 0.42 53.0 43 6 0.53 60.6 46 6 0.58 70.7 88 8 0.63 80.7 94 8 0.69 90.8 76 8 0.89 100.9 80 8 0.95 113.6 85 10 1.11 126.2 89 10 1.19 384 479 575 671 767 895 1023 1151 1279 1438 1598 3080 1960 1810 5200 400-3-50 10.8 3080 1960 1810 5500 3810 1960 1910 6600 3810 1960 1910 7100 3980 2160 2090 8300 3980 2160 2090 8800 4980 2160 2130 10100 4980 2160 2130 10700 5000 2390 2290 13200 5000 2390 2290 13900 5040 2600 2490 16300 5040 2600 2490 17100 10.8 10.8 16.3 16.3 16.3 19.2 19.2 19.2 19.2 26.0 32.9 52 2215 1691 53 2461 1879 61 2813 2147 62 3165 2415 63 3516 2684 71 3868 2952 72 4220 3221 73 4571 3489 81 4923 3757 82 5274 4026 95.4 75 8 0.71 106.0 98 8 0.77 121.2 69 10 0.99 136.3 91 10 1.06 151.4 120 10 1.13 166.5 74 12 1.41 181.7 94 12 1.51 196.8 116 12 1.61 212.0 94 14 1.83 227.1 115 14 1.94 159.0 92 12 2.01 176.6 121 12 2.14 201.9 83 14 2.79 227.1 112 14 2.97 252.3 146 14 3.15 277.6 90 16 3.67 302.8 115 16 3.90 328.0 142 16 4.11 353.3 117 16 4.51 378.5 142 16 4.76 2014 2237 2557 2877 3196 3516 3836 4155 4475 4795 5850 2900 2990 24600 6350 2900 2990 26300 6110 3330 3250 32700 6600 3330 3250 35200 7130 3330 3250 37900 6490 3450 4100 46100 7020 3450 4100 49500 7520 3450 4100 52500 7010 3650 4450 57200 7510 3650 4450 60200 34.9 34.9 41.4 48.7 56.7 58.7 58.7 66.8 68.8 68.8 kW mm kg V-ph-Hz A 16DJ 51 kW 1969 Cooling capacity kW 1503 Heating capacity Chilled/hot-water system* Flow rate l/s 84.8 Pressure drop kPa 56 Connection (ANSI) in 8 0.65 Retention volume m3 Cooling water system* Flow rate l/s 141.3 Pressure drop kPa 68 Connection (ANSI) in 12 1.87 Retention volume m3 Natural gas Fuel type Consumption (cooling/heating)** kW 1790 mm Dimensions Length A 5310 Height B 2900 Width C 2990 kg 22800 Operating weight V-ph-Hz 400-3-50 Power supply Total current drawn A 34.9 * Cooling per ARI 560 2000: 12.2 —> 6.7°C (fouling factor = 0.0176 m2 K/kW) 29.4 —> 35.3°C (fouling factor = 0.044 m2 K/kW) Heating: 55.8 —> 60°C (fouling factor = 0.0176 m2 K/kW) ** Consumption in Nm3/h of gas = Consumption High gas calorific value (kW/h/Nm3) C B A 153 Controls Index System architecture 154 Index Type Fan coil controllers Range Page Electronic thermostats Overview HDB controller NTC controller 156 157 158 160 Aquasmart Evolution 162 Hydronic systems 155 ELECTRONIC THERMOSTATS Controls Thermostats Description Features t $BSSJFSFMFDUSPOJDUIFSNPTUBU range is available for all Carrier hydronic terminals ranges: - Type A - two-pipe application with AC motors - Type B - four-pipe or two-pipe applications with electric heaters with AC motors - Type C - two-pipe application with EC motors - Type D - four-pipe or two-pipe applications with electric heaters with EC motors t 5IFUIFSNPTUBUGPSGBODPJMVOJUT with EC motor option controls three configurable discrete speeds via an 0-10 V signal. t 5IFFMFDUSPOJDUIFSNPTUBUTFUSBOHF is from 10°C to 30°C, with the possibility to limit the temperature in public buildings where low energy consumption is a key requirement. This is done via a dip-switch inside the control (cooling range 23°C/30°C, heating range 10°C/21°C). t "VUPGBOUIFDPOUSPMBVUPNBUJDBMMZTFUTUIFGBOTQFFE*GUIFSPPNUFNQFSBUVSF is far from the set point, high fan speed is selected. As the room temperature approaches the desired value, the fan speed decreases to the minimum speed. t "VUPNBUJDDIBOHFPWFSGSPNDPPMJOHUPIFBUJOHNPEFCBTFEPOUIFXBUFS temperature, ensures that the ideal room temperature is maintained. t 3FNPUFDIBOHFPWFSBVUPNBUJDDIBOHFPWFSGSPNDPPMJOHUPIFBUJOHNPEF based on the remote signal from the monitoring system. t 'SPTUQSPUFDUJPOLFFQTUIFSPPNUFNQFSBUVSFBCPWFBNJOJNVNMFWFM t #PPTUFSIFBUJOHDPOUSPMPQUJNJTBUJPOXJUIFMFDUSJDIFBUFSPQUJPO XJUIUIFXBUFS temperature below 30°C the system will be in heat demand mode and the electric heater is the only available heating source. If the water temperature is above 35°C the system will be in booster heating mode, energising water valve and electric heater together. This function is deactivated if the water temperature is above 45°C (the electric heater will be de-energised). t &OFSHZTBWJOHXIFOUIFSPPNJTVOPDDVQJFEXJUIPVUUIFOFFEUPTXJUDIPòUIF unit. If the energy-saving button is pressed, the actual set point will be modified as follows, without changing the position of the set point selection knob: ± 4 K. t -&%JOUFOTJUZPóDFTPSMJHIUDPNNFSDJBMBQQMJDBUJPOT TFDPOETBGUFSUIFMBTU user interface use all LEDs are reduced in intensity. To avoid disturbing hotel guests, the thermostat can be configured from “Night Mode” to “Dark Mode”: 10 seconds after the last user interface use, all LEDs are switched off. t "JSTBNQMJOHXJUIOPGBOSFRVFTUBOEUIFBJSTBNQMJOHKVNQFSJO0/QPTJUJPO the control performs the air sampling function. The air in the room is moved, thermal stratification is reduced for a more reliable ambient temperature reading. t $POUJOVPVTGBOOPGBOSFRVFTUBOEDPOUJOVPVTGBOKVNQFS0/ UIFDPOUSPMTFMFDUT the fan speed, regardless of thermal station conditions. With fan in auto fan mode and control not in the demand phase, the fan permanently runs at low speed. t &YUFSOBMDPOUBDU"IJHIWPMUBHFJOQVUTJHOBMGPSFYUFSOBMDPOUBDUJTQSFTFOU*GUIF contact is activated, device behaviour depends on its configuration on site: - Presence detection energy saving mode is activated, room temperature is raised by 4 K in cooling mode and reduced by 4 K in heating mode. - Window contact: in OFF mode (window open), all outputs are disconnected (fan, valves, etc.) and only the frost protection function is active, if enabled. 156 Electronic controllers Electronic fan coil controllers - quick reference table Control algorithms On-off Proportional-integral Valve management Air flow control only (no valve) On-off actuators Proportional valves Fan control Three speeds Optimum fan speed selection Variable speed Main functions Setpoint control Occupied/unoccupied mode Frost protection mode Window contact input Measurement of water inlet temperature for automatic seasonal changeover (2 pipes) Automatic seasonal changeover (4 pipes and 2 pipes + electric heater) Manual changeover Frost protection mode Continuous ventilation within dead-band Periodical ventilation within dead-band On-site configuration Unit grouping Louvre control Supply air temperature monitoring limiting Communication (CCN) Electrical heater loadshed Dirty filter alarm Alarm reporting IAQ control Demand control ventilation (DCV) Free cooling mode User interface Digital display Automatic or manual fan speed control Operating mode selection Occupancy (eco) button Thermostats HDB x x NTC x x x x x x x x x x x x x x x x x x types A + C x types D + B x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x o o o x x x x x x x x x x x 157 x o HDB CONTROLLER Controls HDB User interfaces Features Depending on the application, two user interface types can be selected: t BXJSFEVTFSJOUFSGBDFUIBUDBO be mounted on the wall or inside compatible terminal fan coils (42N) t BOJOGSBSFEVTFSJOUFSGBDFUPCF used together with a wall-mounted infrared received or a receiver incorporated in compatible terminal fan coils (42GW) t 5IF)%#DPOUSPMMFSJTBNJDSPQSPDFTTPSCBTFEDPOUSPMMFSEFTJHOFEUPDPOUSPM and optimise the operation of hydronic terminal fan coil units. t 'BDUPSZJOTUBMMFEPOUIFUFSNJOBMGBODPJM5IFDPOUSPMMFSJTGBDUPSZJOTUBMMFE on the terminal fan coil; the assembly is also tested at the factory. As a result, field installation is extremely simple. t &BTFPGHSPVQJOH"TBOPQUJPOUIF)%#DPOUSPMDBOCFFRVJQQFEXJUIB grouping board that is used to connect up to 15 units with a bus. All units connected together will operate under the same conditions. t -PVWSFDPOUSPM'PSUFSNJOBMGBODPJMTFRVJQQFEXJUINPUPSJTFEMPVWSFTUIF HDB controls the louvre position as defined by the user or in swing mode. t &YUFSOBMDPOUBDU5IFDPOUSPMIBTBOJOQVUUIBUDBOCFVTFEUPSFNPUFMZTFU the unit to economy mode. t 4DIFEVMJOH*GUIFVOJUJTVTFEXJUIBOJOGSBSFEVTFSJOUFSGBDFVOJUPQFSBUJPO time can be scheduled on a daily basis. Three start times and three stop times can be programmed. t 5JNFS*GUIFVOJUJTVTFEXJUIBOJOGSBSFEVTFSJOUFSGBDFJUDBOPQFSBUFGPSB predefined duration before switching to eco mode or off. 158 HDB controller 56 Carrier Room Conroller (CRC2( 250 Infrared Remote Control (IR2) and receiver 190 159 HYDRONIC FAN COIL COMMUNICATING CONTROLLER (NTC) Controls NTC Network communication Description t 5IF/5$DPNNVOJDBUJOHDPO troller can be connected on an RS 485 bus, using the Carrier Comfort Network (CCN) protocol. t 6OJUTFRVJQQFEXJUIUIF/5$ controller can be part of the Aquasmart Evolution system. Carrier offers one of the market’s most sophisticated and complete communicating controllers for hydronic fan coil ranges, the NTC controller, that is compatible with the full Carrier fan coil range. For the customer and installer the same controller simplifies and eases installation and service operations whilst covering a wide range of hydronic system types and applications. The controller can be applied and function as either a standalone control, as part of a larger CCN system application, or at the heart of a Aquasmart system functioning with the Aquasmart Touch Pilot System Manager. Advanced functions t -PX&OFSHZ$POTVNQUJPO-&$ variable speed control. t 5IF/5$DPOUSPMMFSDBOESJWFUIF fan speed continuously within a configurable range for optimal thermal and acoustic comfort. t )ZESPOJDDPOUSPM5IF/5$ controls both floating and fixedpoint value actuator types (230 V on-off and 230 V three point). t %FNBOEDPOUSPMMFSWFOUJMBUJPO (DCV) - On fan coils equipped with CO2 sensors and fresh air dampers, the NTC controller can adjust the amount of fresh air admitted to the room, as required by the occupants. t *"2NBOBHFNFOU5IF/5$ controller can control all features related to Indoor Air Quality that are included in Carrier terminal fan coil units. Features t 5IF/5$DPOUSPMMFSDPOUSPMTBOEPQUJNJTFTUIFPQFSBUJPOPGIZESPOJDUFSNJOBM fan coil units. It is a microprocessor-based CCN (Carrier Comfort Network) compatible communicating controller with energy-saving algorithms. t &OFSHZTBWJOHBMHPSJUINTNBOBHFXBUFSWBMWFPQFSBUJPOBOEGBOTQFFE control simultaneously to ensure minimum energy consumption whilst maximising comfort conditions for the occupant. t 'BDUPSZJOTUBMMFEPOUFSNJOBMGBODPJMT The NTC controller is factory-installed on the terminal fan coil; the assembly is also factory-tested. As a result, field installation is extremely simple. t "XJEFSBOHFPGVTFSJOUFSGBDFT Depending on the application, two user interface types can be selected: - a simplified wired analogue user interface (SUI) that can be wall-mounted - a wired communicating user interface (CRC2) that can be wall-mounted or incorporated in compatible terminal fan coils (42N) - an infrared user interface (IR2) for use together with a wall-mounted infrared received or a receiver incorporated on compatible terminal fan coils (42GW) - a multi-function user interface (ZUI) that can control comfort, lights and blinds within a Carrier system 160 NTC controller 56 Carrier Room Conroller (CRC2( Simplified User Interface (SUI) 250 Zone User Interface (ZUI) Infrared Remote Control (IR2) and receiver 190 2 1 1 3 1 3 4a 4b 1 1 3 5 A Legend 1 NTC controller 2 Secondary communication bus 3 User interface connection 4 IR2 5 ZUI2 6 CRC2 A Room A B Room B 161 6 B AQUASMART EVOLUTION FEATURING THE NEW TOUCH PILOT SYSTEM MANAGER Controls Aquasmart Description Features t "RVBTNBSU&WPMVUJPOJTBDPNQMFUF hydronic heating, ventilating and air conditioning (HVAC) system ideal for residential and light commercial applications from offices, commerce to hotels and hospitals. It offers perfect comfort for building occupants whilst optimising economical operation for applications up to 2500 m2. Larger installations with multiple systems can be managed and integrated within a single Building Management solution thanks to the new BACnet option capability (available as option in 2012). t "O"RVBTNBSUTZTUFNDPOTJTUTPGVQ to 128 terminal fan coil units, served by up to two chillers or heat pumps (master-slave), to supply cooling and/ or heating to occupied spaces and fresh air handling units. The system manager can fully integrate and control up to eight Carrier fresh air handling units* (39SQ). Each fresh air plant can be associated with specific terminal fan coils and/or zones for optimum building use management with occupancy, controlling and minimising energy use. t *OEJWJEVBMTDIFEVMFTDBOCFTFUVQ and managed for each and all air treatment plants. The Aquasmart System Manager supplies building information enabling dynamic and precise control of the 39SQ’s nighttime free-cooling feature to further reduce building energy consumption. t 5IF"RVBTNBSU&WPMVUJPOTZTUFNFOTVSFTTJHOJmDBOUFOFSHZTBWJOHTDPNCJOFE with optimised user comfort by managing building zoning, occupancy and room temperatures in accordance with needs. t 5FSNJOBMGBODPJMVOJUTDBOCFPSHBOJTFEJOVQUP[POFTUPPQUJNJTFCVJMEJOH management by zone requirement and according to building design conditions. t 5IF5PVDI1JMPU4ZTUFN.BOBHFSoUIFCSBJOBOECVJMEJOHVTFSJOUFSGBDFoXBT designed to facilitate use and allow rapid access to manage and configure system operation to maximise energy savings at comfort conditions. t 4ZTUFNDPNQPOFOUTBSFmUUFEXJUIDPNNVOJDBUJOHDPOUSPMTBMMPXJOHUIF System Manager to communicate with and obtain feedback on user needs and operation. Based on the system requirements the System Manager coordinates the system heating and cooling modes for maximum comfort and optimal energy consumption, respecting the comfort parameters and occupancy schedules for the building zones. t 5IF"RVBTNBSUTZTUFNPòFSTBòPSEBCMFCVJMEJOH)7"$TZTUFNNBOBHFNFOU featuring capabilities usually only available in more expensive solutions and requiring additional building-by-building programming development. * If air treatment unit is not supplied by Carrier, integration is limited to control via a digital output for the main fresh-air unit. 162 Aquasmart System design layout and configuration guide Energy savings t 5IF4ZTUFN.BOBHFSJTDPOOFDUFEUPUIFTZTUFN components via a communication bus, and allows control of all system and individual terminal operating parameters. t 4ZTUFNDPOmHVSBUJPOJTTJNQMFUISPVHIFBTJMZBDDFTTJCMF menus. Unit grouping is managed by the network and requires no specific wiring to allow easy reconfiguration to suit later building layout modifications. t 5IF"RVBTNBSU&WPMVUJPODPNQPOFOUTBSFEFMJWFSFE complete, configured and factory-tested. t 5IF"RVBTNBSUTZTUFNDPOUSPMTPòFSTVQFSJPSDPNGPSU levels. By optimising and controlling the system components building owners and occupants can save energy and reduce their energy bill, contributing to a reduction in building carbon emissions. t 4ZTUFNDPOUSPMTBWJOHQPTTJCJMJUJFTBSFGVSUIFSFOIBODFE with a range of significant energy-saving features available at equipment level, such as the 39SQ plugand-play fresh air handling unit with heat recovery technology, the use of reversible 30RQ air-to-water heat pumps for space heating, 61AF heat pumps for domestic hot water and a range of fan coil units with EC motor technology and variable fan speed control. t &OFSHZTJNVMBUJPOTDPOEVDUFEXJUIBSFDPHOJTFE software simulation program indicate that Aquasmart can achieve energy savings over a traditional noncommunicating and non-optimised system. Case studies indicate that savings of 25% and beyond are possible. Each project merits its own assessment of the opportunities. 163 Aquasmart New System Manager System selection t 5IF5PVDI1JMPUTZTUFNNBOBHFSJTUIFVTFSJOUFSGBDF and allows building managers to control the Aquasmart system and associated components and features. - Intuitive colour touch screen. - A system set-up wizard leads installers through a number of easy intuitive steps to identify and configure the system and manage system set-up, operation and maintenance. - Icon-driven menus easily and rapidly manage and maintain the HVAC system. - Management of system parameters including cooling and heating set points (terminals and cooling and/or heating plants) and occupied and non-occupied periods. - Optimisation of energy consumption, monitoring of component operation and reporting of system faults. - Management of occupied/unoccupied time schedules and smart start features to ensure that comfort requirements are met from the very beginning of the occupied period. t 5IF4ZTUFN.BOBHFSJTDPNQBUJCMFXJUIBXFCCSPXTFS allowing user access to the system from a remote location such as a maintenance office within the building or from an off-site location where internet access is available. This facilitates ease-of-access and use and allows service and maintenance companies to offer remote service coverage without visiting the site, thus reducing carbon emissions due to transport. t 5IFBWBJMBCJMJUZPGBOFX$BSSJFS"QQMFBQQMJDBUJPO (HVAC smart browser) extends the accessibility to smart phones and tablets. t 5IF"RVBTNBSUTZTUFNJTFBTZUPTFMFDUBOEDPOmHVSF with all units supplied from the factory with preinstalled, pre-configured and pre-tested controls and valves. The installer only needs to adjust the system parameters to the local building or application needs - a task made even easier with the New System Manager. t $BSSJFSIBTDSFBUFEB2VJDL4FMFDUJPO(VJEFUIBUJTBWBJMBCMF to rapidly identify and select the system components, facilitating the design process and saving time for designers and installers alike. t 1MFBTFDPOUBDUZPVSMPDBMTBMFTPóDFGPSBDPQZPGUIJT guide. 164 Aquasmart Building Management System Integration t 5IFMBUFTUSFMFBTFPGUIF"RVBTNBSU5PVDI1JMPUTZTUFN manager enhances the capabilities to integrate Aquasmart systems with Carrier or third-party building management system front-end software. The new BACnet option allows access to read and read/write system parameters from the building management system facilitating integration of Aquasmart within the overall building management. System Manager Heat pump Primary bus Secondary bus 3 3 3 3 4a 4b Legend: 1 NTC controller 2 Secondary communication bus 3 User interface connection 4 Infrared controller IR2 5 ZUI2 A 6 7 A B SUI CRC2 Room A Room B 165 B March 2014 Manufacturer reserves the right to change any product specifications without notice.