SIRIUS M200D
Transcrição
SIRIUS M200D
SIRIUS M200D Supplementary products Release 01/2012 M200D Supplementary products Order note: The articles and order numbers listed in this catalogue are special numbers, which were created within the context of the partnership between Siemens and HARTING. Order processing is only possible within the framework of this partnership for the Siemens product range. Prices (UPE) at this Catalogue are recommended sales prices. A binding quotation with your conditions you will receive via your responsible HARTING subsidiary company. Send your inquiry to: Contact and delivery address: HARTING Deutschland GmbH & Co. KG For technical questions: mailto:[email protected] mailto:[email protected] Heike Sielaff Tel. +49 571 8896-223 Simeonscarré 1 32427 Minden Germany Andreas Scheuer Tel. +49 571 8896-263 Edition 01/2012 Page 2 Sven Wessel Tel. +49 571 8896-335 M200D Supplementary products SIRIUS M200D Table of contents 1 Energy – Connection ------------------------------------------------------------------------------- 5 1.1 Energy T-terminal connector --------------------------------------------------------------------- 5 1.2 Energy T-connector for power bus max. 25mm² --------------------------------------------- 6 1.3 Energy double T-terminal connector ------------------------------------------------------------ 6 1.4 Power bus cable -------------------------------------------------------------------------------------- 7 1.4.1 Power bus cable (sold by ring) 2,5mm² --------------------------------------------------- 7 1.4.2 Power bus cable (sold by ring) 4,0mm² --------------------------------------------------- 7 1.4.3 Power bus cable (sold by ring) 6,0mm² --------------------------------------------------- 7 2 Power cable ------------------------------------------------------------------------------------------ 8 2.1 Power cables for motor starter M200D prefabricated --------------------------------------- 8 2.1.1 Cross section 2,5mm², w/o N-Conductor ------------------------------------------------- 8 2.1.1.1 Cross section 2,5mm², with N-Conductor --------------------------------------------- 8 2.1.2 Cross section 4,0mm², w/o N-Conductor ------------------------------------------------- 9 2.1.2.1 Cross section 4,0mm², with N-Conductor --------------------------------------------- 9 2.1.3 Cross section 6,0mm², w/o N-Conductor ------------------------------------------------- 9 2.1.3.1 Cross section 6,0mm², with N-Conductor --------------------------------------------- 9 2.2 Power cables for motor starter M200D one-sided prefabricated -------------------------- 10 2.2.1 Cross section 2,5mm², w/o N-Conductor ------------------------------------------------ 10 2.2.1.1 Cross section 2,5mm², with N-Conductor -------------------------------------------- 10 2.2.2 Cross section 4mm² without N-Conductor ---------------------------------------------- 11 2.2.2.1 Cross section 4mm² with N-Conductor ----------------------------------------------- 11 2.2.3 Cross section 6mm² without N-Conductor ---------------------------------------------- 11 2.2.3.1 Cross section 6mm² mit N-Leiter ------------------------------------------------------ 11 2.3 Power cable (sold by the ring) ------------------------------------------------------------------- 12 2.3.1 Power cables (sold by the ring) 2,5mm², w/o N-Conductor ------------------------- 12 2.3.1.1 Power cables (sold by the ring) 2,5mm², with N-Conductor --------------------- 12 2.3.2 Power cables (sold by the ring) 4,0mm², w/o N-Conductor ------------------------- 12 2.3.2.1 Power cables (sold by the ring) 4,0mm², with N-Conductor --------------------- 12 2.3.3 Power cables (sold by the ring) 6,0mm², w/o N-Conductor ------------------------- 12 2.3.3.1 Power cables (sold by the ring) 6,0mm², with N-Conductor --------------------- 12 2.4 Connector set for power cable ------------------------------------------------------------------- 13 3 Motor connection ----------------------------------------------------------------------------------14 3.1 Motor cable for motors in star connection, prefabricated ---------------------------------- 14 3.1.1 Without Brake, without Temperature transmitter -------------------------------------- 14 3.1.1.1 Cross section 1,5mm² -------------------------------------------------------------------- 14 3.1.1.2 Cross section 2,5mm² -------------------------------------------------------------------- 15 Edition 01/2012 Page 3 M200D Supplementary products 3.1.2 With Brake (Brake voltage 400VAC or 180VDC), w/o Temperature transmitter 15 3.1.2.1 Cross section 1,5mm² -------------------------------------------------------------------- 15 3.1.2.2 Cross section 2,5mm² -------------------------------------------------------------------- 15 3.1.3 With Brake (Brake voltage 230VAC), w/o Temperature transmitter -------------- 16 3.1.3.1 Cross section 1,5mm² -------------------------------------------------------------------- 16 3.1.3.2 Cross section 2,5mm² -------------------------------------------------------------------- 16 3.1.4 With Brake (Brake voltage 400VAC or 180VDC), with Temperature transmitter 16 3.1.4.1 Cross section 1,5mm² -------------------------------------------------------------------- 16 3.1.4.2 Cross section 2,5mm² -------------------------------------------------------------------- 17 3.1.5 With Brake (Brake voltage 230VAC), with Temperature transmitter ------------- 17 3.1.5.1 Cross section 1,5mm² -------------------------------------------------------------------- 17 3.1.5.2 Cross section 2,5mm² -------------------------------------------------------------------- 17 3.2 Motor cable for motors in star connection, one-sided prefabricated --------------------- 18 3.2.1 Without Brake, without Temperature transmitter -------------------------------------- 18 3.2.1.1 Cross section 1,5mm² -------------------------------------------------------------------- 18 3.2.1.2 Cross section 2,5mm² -------------------------------------------------------------------- 18 3.2.2 With Brake (Brake voltage 400VAC or 180VDC), w/o Temperature transmitter 19 3.2.2.1 Cross section 1,5mm² -------------------------------------------------------------------- 19 3.2.2.2 Cross section 2,5mm² -------------------------------------------------------------------- 19 3.2.3 With Brake (Brake voltage 230VAC), w/o Temperature transmitter -------------- 19 3.2.3.1 Cross section 1,5mm² -------------------------------------------------------------------- 19 3.2.3.2 Cross section 2,5mm² -------------------------------------------------------------------- 19 3.2.4 With Brake (Brake voltage 400VAC or 180VDC), with Temperature transmitter 20 3.2.4.1 Cross section 1,5mm² -------------------------------------------------------------------- 20 3.2.4.2 Cross section 2,5mm² -------------------------------------------------------------------- 20 3.2.5 With Brake (Brake voltage 230VAC), with Temperature transmitter ------------- 20 3.2.5.1 Cross section 1,5mm² -------------------------------------------------------------------- 20 3.2.5.2 Cross section 2,5mm² -------------------------------------------------------------------- 20 3.3 Motor cable - sold by the ring ------------------------------------------------------------------- 21 3.3.1 Motor cable 1,5mm² - sold by the ring --------------------------------------------------- 21 3.3.2 Motor cable 2,5mm² - sold by the ring --------------------------------------------------- 21 3.4 Set of connector for motor connection cable, on the side of the motor starter (M200D) 22 3.5 Sets of connectors on the side of the motor --------------------------------------------------- 23 4 Accessories ------------------------------------------------------------------------------------------24 4.1 4.2 4.3 4.4 Set of connectors for power bus switching cabinet / subdistributor --------------------- 24 Protective cover ------------------------------------------------------------------------------------- 25 Crimping tool---------------------------------------------------------------------------------------- 25 Dismantle tool for male and female inserts---------------------------------------------------- 25 Technical Datasheets Page 27 – 63 Index list of products Page 65 – 66 List of HARTING Subsidiary Companies Page 67 Edition 01/2012 Page 4 M200D Supplementary products 1 Energy – Connection 1.1 Energy T-terminal connector Order Number HTG:61 88 201 0500 HTG:61 88 201 0501 HTG:61 88 201 0502 HTG:61 88 201 0503 HTG:61 88 201 0504 HTG:61 83 401 0200 HTG:61 83 401 0201 HTG:61 83 401 0202 HTG:61 83 401 0203 HTG:61 83 401 0204 Edition 01/2012 Page 5 Description Energy T-terminal connector for power bus cable from 2,5mm² up to 4mm² With built-in 7-pole connector, female insert, hood, UL Energy T-terminal connector for power bus cable from 4mm² up to 6mm² With built-in 7-pole connector, female insert, hood, UL Energy T-terminal connector Length 2,5m and 7-pole connector, female insert, hood, for power bus cable from 2,5mm² till 4mm² with connected cable 5 x 2,5mm² for power bus cable from 4mm² till 6mm² with connected cable 5 x 4mm² for power bus cable from 4mm² till 6mm² with connected cable 5 x 6mm² Sealing for cable 10 – 13mm 1set =2 pieces Sealing for cable 13 – 16mm 1set =2 pieces Sealing for cable 16 – 19mm 1set =2 pieces Sealing for cable 19 – 22mm 1set =2 pieces Sealing blind grommet 1 piece UPE € 32,22 32,22 45,95 49,15 53,92 1,38 1,38 1,38 1,38 0,88 M200D Supplementary products 1.2 Energy T-connector for power bus max. 25mm² Han Q4/2 Order Number HTG:61 88 201 0181 1.3 Description Energy T-terminal connector for power bus cable up to 25mm² for power bus cross sectional change or power bus extension Glands M25 for cable cross section from 13 mm up to 18 mm With built-in 7-pole connector, female insert, hood UPE € 70,22 Energy double T-terminal connector Seal 2xHAN Q4/2-Female Order Number HTG: 61 88 202 0770 HTG:09 12 000 9970SI HTG:09 12 000 9971SI HTG:09 12 000 9972SI HTG:09 12 000 9973SI HTG:09 12 000 9974SI Edition 01/2012 Page 6 Description Energy double T-terminal connector for bus cable from 4mm² up to 6mm² With two built-in 7-pole connector, female insert, hood, UL Sealing for cable 10 – 13mm 1set =2 pieces Sealing for cable 13 – 16mm 1set =2 pieces Sealing for cable 16 – 19mm 1set =2 pieces Sealing for cable 19 – 22mm 1set =2 pieces Sealing blind grommet 1 piece UPE € 51,73 1,38 1,38 1,38 1,38 1,38 M200D Supplementary products 1.4 Power bus cable 1.4.1 Power bus cable (sold by ring) 2,5mm² Order Number HTG:61 88 600 0101 HTG:61 88 600 0102 on request Description Power bus cable, 5x2,5mm² Length 50m Length 100m Length >100m UPE € 220,52 426,10 1.4.2 Power bus cable (sold by ring) 4,0mm² Order Number HTG:61 88 600 0107 HTG:61 88 600 0108 on request Description Power bus cable, 5x4,0mm² Length 50m Length 100m Length >100m UPE € 312,02 609,03 1.4.3 Power bus cable (sold by ring) 6,0mm² Order Number HTG:61 88 600 0113 HTG:61 88 600 0114 on request Edition 01/2012 Page 7 Description Power bus cable, 5x6,0mm² Length 50m Length 100m Length >100m UPE € 450,37 885,77 M200D Supplementary products 2 Power cable 2.1 Power cables for motor starter M200D prefabricated HanQ 4/2 Housing (with bracket) male insert HanQ 4/2 Hood, side entry female insert Power cable 2.1.1 Cross section 2,5mm², w/o N-Conductor Order number HTG:61 88 202 0400 HTG:61 88 202 0401 HTG:61 88 202 0402 HTG:61 88 202 0403 Description Power cable for M200D HAN Q4/2 top entry - HAN Q4/2 side entry 4x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 43,93 50,09 58,29 78,81 2.1.1.1 Cross section 2,5mm², with N-Conductor Order number HTG:61 88 202 0693 HTG:61 88 202 0694 HTG:61 88 202 0695 HTG:61 88 202 0696 Edition 01/2012 Page 8 Description Power cable (N) for M200D HAN Q4/2 top entry - HAN Q4/2 side entry 5x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 45,78 52,53 62,80 83,23 M200D Supplementary products 2.1.2 Cross section 4,0mm², w/o N-Conductor Order number HTG:61 88 202 0404 HTG:61 88 202 0405 HTG:61 88 202 0406 HTG:61 88 202 0407 Description Power cable for M200D HAN Q4/2 top entry - HAN Q4/2 side entry 4x4,0mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 46,91 55,86 67,76 97,57 2.1.2.1 Cross section 4,0mm², with N-Conductor Order number HTG:61 88 202 0697 HTG:61 88 202 0698 HTG:61 88 202 0699 HTG:61 88 202 0700 Description Power cable (N) for M200D HAN Q4/2 top entry - HAN Q4/2 side entry 5x4,0mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 52,13 64,35 81,60 126,54 2.1.3 Cross section 6,0mm², w/o N-Conductor Order number HTG:61 88 202 0408 HTG:61 88 202 0409 HTG:61 88 202 0410 HTG:61 88 202 0411 Description Power cable for M200D HAN Q4/2 top entry - HAN Q4/2 side entry 4x6,0mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 51,77 64,83 82,27 125,82 2.1.3.1 Cross section 6,0mm², with N-Conductor Order number HTG:61 88 202 0701 HTG:61 88 202 0702 HTG:61 88 202 0703 HTG:61 88 202 0704 Edition 01/2012 Page 9 Description Power cable (N) for M200D HAN Q4/2 top entry - HAN Q4/2 side entry 5x6,0mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 53,93 68,73 88,45 135,67 M200D Supplementary products 2.2 Power cables for motor starter M200D one-sided prefabricated End open HanQ 4/2 Hood, side entry female insert Power cable 2.2.1 Cross section 2,5mm², w/o N-Conductor Order number HTG:61 88 201 0192 HTG:61 88 201 0193 HTG:61 88 201 0194 HTG:61 88 201 0195 Description Power cable for M200D open - HAN Q4/2 side entry 4x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 25,63 31,57 39,78 60,28 2.2.1.1 Cross section 2,5mm², with N-Conductor Order number HTG:61 88 201 0458 HTG:61 88 201 0459 HTG:61 88 201 0460 HTG:61 88 201 0461 Edition 01/2012 Page 10 Description Power cable (N) for M200D open - HAN Q4/2 side entry 5x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 27,19 34,46 44,27 67,95 M200D Supplementary products 2.2.2 Cross section 4mm² without N-Conductor Order number HTG:61 88 201 0196 HTG:61 88 201 0197 HTG:61 88 201 0198 HTG:61 88 201 0199 Description Power cable for M200D open - HAN Q4/2 side entry 4x4,0mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 27,88 34,94 44,67 69,02 2.2.2.1 Cross section 4mm² with N-Conductor Order number HTG:61 88 201 0462 HTG:61 88 201 0463 HTG:61 88 201 0464 HTG:61 88 201 0465 Description Power cable (N) for M200D open - HAN Q4/2 side entry 5x4,0mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 30,08 40,31 55,06 91,91 2.2.3 Cross section 6mm² without N-Conductor Order number HTG:61 88 201 0200 HTG:61 88 201 0201 HTG:61 88 201 0202 HTG:61 88 201 0203 Description Power cable for M200D open - HAN Q4/2 side entry 4x6,0mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 31,59 42,02 56,40 92,31 2.2.3.1 Cross section 6mm² mit N-Leiter Order number HTG:61 88 201 0466 HTG:61 88 201 0467 HTG:61 88 201 0468 HTG:61 88 201 0469 Edition 01/2012 Page 11 Description Power cable (N) for M200D open - HAN Q4/2 side entry 5x6,0mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 35,57 48,08 65,96 106,60 M200D Supplementary products 2.3 Power cable (sold by the ring) 2.3.1 Power cables (sold by the ring) 2,5mm², w/o N-Conductor Order number HTG:61 88 600 0115 HTG:61 88 600 0116 on request Description Power cable 4x2,5mm² Length 50m Length 100m Length >100m UPE € 175,77 353,32 2.3.1.1 Power cables (sold by the ring) 2,5mm², with N-Conductor Order number HTG:61 88 600 0101 HTG:61 88 600 0102 on request Description Power cable 5x2,5mm² Length 50m Length 100m Length >100m UPE € 220,52 426,10 2.3.2 Power cables (sold by the ring) 4,0mm², w/o N-Conductor Order number HTG:61 88 600 0117 HTG:61 88 600 0118 on request Description Power cable 4x4,0mm² Length 50m Length 100m Length >100m UPE € 241,79 468,64 2.3.2.1 Power cables (sold by the ring) 4,0mm², with N-Conductor Order number HTG:61 88 600 0107 HTG:61 88 600 0108 on request Description Power cable 5x4,0mm² Length 50m Length 100m Length >100m UPE € 312,01 609,03 2.3.3 Power cables (sold by the ring) 6,0mm², w/o N-Conductor Order number HTG:61 88 600 0119 HTG:61 88 600 0120 on request Description Power cable 4x6mm² Length 50m Length 100m Length >100m UPE € 349,05 683,11 2.3.3.1 Power cables (sold by the ring) 6,0mm², with N-Conductor Order number HTG:61 88 600 0113 HTG:61 88 600 0114 on request Edition 01/2012 Page 12 Description Power cable 5x6mm² Length 50m Length 100m Length >100m UPE € 450,37 885,77 M200D Supplementary products 2.4 Connector set for power cable HanQ 4/2 Housing (with bracket) Male insert Power supply cable Order number HTG:61 04 401 0556 HTG:61 04 401 0545 HTG:61 04 401 0550 HTG:61 04 401 0502 Edition 01/2012 Page 13 HanQ 4/2 Hood side entry Female insert Top down Description Set of connectors power cable e.g. for connection to the T-terminal connector consisting of housing, outgoing circuit top entry (with bracket) Male insert for Han Q4/2, UL Gland for cable size 11,5 – 15,5 mm 5 male contacts 4mm² 5 male contacts 6mm² Set of connectors for power cable for connection M200D Hood, outgoing circuit side entry Female insert for Han Q4/2, UL Gland for cable size 11,5 – 15,5 mm 5 female contacts 4mm² 5 female contacts 6mm² UPE € 13,18 13,18 15,24 15,24 M200D Supplementary products 3 Motor connection 3.1 Motor cable for motors in star connection, prefabricated Motor Han 10 E female insert with star bridge Motor with HanDrive Motor cable 3.1.1 Motor – connection cable with HanQ 8/0 connector Without Brake, without Temperature transmitter 3.1.1.1 Cross section 1,5mm² Order number HTG:61 88 202 0424 HTG:61 88 202 0425 HTG:61 88 202 0426 Edition 01/2012 Page 14 Description Motor cable for M200D w/o Brake, w/o Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 4x1,5mm² Length 1,5m Length 3m Length 5m UPE € 42,84 47,12 52,80 M200D Supplementary products 3.1.1.2 Cross section 2,5mm² Order number HTG:61 88 202 0427 HTG:61 88 202 0428 HTG:61 88 202 0429 3.1.2 Description Motor cable for M200D w/o Brake, w/o Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 4x2,5mm² Length 1,5m Length 3m Length 5m UPE € 43,47 48,31 54,79 With Brake (Brake voltage 400VAC or 180VDC), w/o Temperature transmitter 3.1.2.1 Cross section 1,5mm² Order number HTG:61 88 202 0607 HTG:61 88 202 0608 HTG:61 88 202 0609 Description Motor cable for M200D with Brake, w/o Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 6x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for M200D with Brake, w/o Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 6x2,5mm² Length 1,5m Length 3m Length 5m UPE € 43,89 47,98 55,84 3.1.2.2 Cross section 2,5mm² Order number HTG:61 88 202 0610 HTG:61 88 202 0611 HTG:61 88 202 0612 Edition 01/2012 Page 15 45,04 51,25 59,51 M200D Supplementary products 3.1.3 With Brake (Brake voltage 230VAC), w/o Temperature transmitter 3.1.3.1 Cross section 1,5mm² Order number HTG:61 88 202 0705 HTG:61 88 202 0706 HTG:61 88 202 0707 Description Motor cable for M200D with Brake, w/o Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 6x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for M200D with Brake, w/o Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 6x2,5mm² Length 1,5m Length 3m Length 5m UPE € 43,89 47,98 55,84 3.1.3.2 Cross section 2,5mm² Order number HTG:61 88 202 0708 HTG:61 88 202 0709 HTG:61 88 202 0710 3.1.4 45,04 51,25 59,51 With Brake (Brake voltage 400VAC or 180VDC), with Temperature transmitter 3.1.4.1 Cross section 1,5mm² Order number HTG:61 88 202 0682 HTG:61 88 202 0683 HTG:61 88 202 0684 Edition 01/2012 Page 16 Description Motor cable for M200D with Brake, with Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 8x1,5mm² Length 1,5m Length 3m Length 5m UPE € 49,88 58,33 69,31 M200D Supplementary products 3.1.4.2 Cross section 2,5mm² Order number HTG:61 88 202 0685 HTG:61 88 202 0686 HTG:61 88 202 0687 Description Motor cable for M200D with Brake, with Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 8x2,5mm² Length 1,5m Length 3m Length 5m UPE € 58,54 72,98 93,96 3.1.5 With Brake (Brake voltage 230VAC), with Temperature transmitter 3.1.5.1 Cross section 1,5mm² Order number HTG:61 88 202 0711 HTG:61 88 202 0712 HTG:61 88 202 0713 Description Motor cable for M200D with Brake 230V, with Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 8x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for M200D with Brake 230V, with Temperature transmitter with star bridge HAN Q8/0 side entry - HAN 10E 8x2,5mm² Length 1,5m Length 3m Length 5m UPE € 59,88 58,33 69,31 3.1.5.2 Cross section 2,5mm² Order number HTG:61 88 202 0714 HTG:61 88 202 0715 HTG:61 88 202 0716 Edition 01/2012 Page 17 58,54 72,98 93,96 M200D Supplementary products 3.2 Motor cable for motors in star connection, one-sided prefabricated End open Motor cable 3.2.1 Motor – connection cable with HanQ 8/0 connector Without Brake, without Temperature transmitter 3.2.1.1 Cross section 1,5mm² Order number HTG:61 88 201 0211 HTG:61 88 201 0212 HTG:61 88 201 0213 Description Motor cable for M200D for Motor w/o Brake, w/o Temperature transmitter HAN Q8/0 side entry - open 4x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for M200D for Motor w/o Brake, w/o Temperature transmitter HAN Q8/0 side entry - open 4x2,5mm² Length 1,5m Length 3m Length 5m UPE € 19,70 23,83 29,51 3.2.1.2 Cross section 2,5mm² Order number HTG:61 88 201 0214 HTG:61 88 201 0215 HTG:61 88 201 0216 Edition 01/2012 Page 18 20,31 25,01 31,48 M200D Supplementary products 3.2.2 With Brake (Brake voltage 400VAC or 180VDC), w/o Temperature transmitter 3.2.2.1 Cross section 1,5mm² Order number HTG:61 88 201 0218 HTG:61 88 201 0219 HTG:61 88 201 0220 Description Motor cable for M200D for Motor with Brake, w/o Temperature transmitter, HAN Q8/0 side entry - open 6x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for M200D for Motor with Brake, w/o Temperature transmitter, HAN Q8/0 side entry - open 6x2,5mm² Length 1,5m Length 3m Length 5m UPE € 20,86 25,61 32,24 3.2.2.2 Cross section 2,5mm² Order number HTG:61 88 201 0221 HTG:61 88 201 0222 HTG:61 88 201 0223 21,46 27,88 34,21 3.2.3 With Brake (Brake voltage 230VAC), w/o Temperature transmitter 3.2.3.1 Cross section 1,5mm² Order number HTG:61 88 201 0470 HTG:61 88 201 0471 HTG:61 88 201 0472 Description Motor cable for M200D for Motor with Brake 230V, w/o Temperature transmitter, HAN Q8/0 side entry - open 6x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for M200D for Motor with Brake 230V, w/o Temperature transmitter, HAN Q8/0 side entry - open 6x2,5mm² Length 1,5m Length 3m Length 5m UPE € 20,86 25,61 32,24 3.2.3.2 Cross section 2,5mm² Order number HTG:61 88 201 0473 HTG:61 88 201 0474 HTG:61 88 201 0475 Edition 01/2012 Page 19 21,46 27,88 34,21 M200D Supplementary products 3.2.4 With Brake (Brake voltage 400VAC or 180VDC), with Temperature transmitter 3.2.4.1 Cross section 1,5mm² Order number HTG:61 88 201 0452 HTG:61 88 201 0453 HTG:61 88 201 0454 Description Motor cable for M200D for Motor with Brake, with Temperature transmitter, HAN Q8/0 side entry - open 8x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for M200D for Motor with Brake, with Temperature transmitter, HAN Q8/0 side entry - open 8x2,5mm² Length 1,5m Length 3m Length 5m UPE € 24,84 33,05 44,54 3.2.4.2 Cross section 2,5mm² Order number HTG:61 88 201 0455 HTG:61 88 201 0456 HTG:61 88 201 0457 33,16 48,19 69,00 3.2.5 With Brake (Brake voltage 230VAC), with Temperature transmitter 3.2.5.1 Cross section 1,5mm² Order number HTG:61 88 201 0476 HTG:61 88 201 0477 HTG:61 88 201 0478 Description Motor cable for M200D for Motor with Brake 230V, with Temperature transmitter, HAN Q8/0 side entry - open 8x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for M200D for Motor with Brake 230V, with Temperature transmitter, HAN Q8/0 side entry - open 8x2,5mm² Length 1,5m Length 3m Length 5m UPE € 24,84 33,05 44,54 3.2.5.2 Cross section 2,5mm² Order number HTG:61 88 201 0479 HTG:61 88 201 0480 HTG:61 88 201 0481 Edition 01/2012 Page 20 33,16 48,19 69,00 M200D Supplementary products 3.3 Motor cable - sold by the ring 3.3.1 Motor cable 1,5mm² - sold by the ring Order number HTG:61 88 600 0121 HTG:61 88 600 0122 HTG:61 88 600 0123 HTG:61 88 600 0124 HTG:61 88 600 0129 HTG:61 88 600 0130 Description Motor cable 4x1,5mm² Length 10m Length 50m Motor cable 6x1,5mm² Length 10m Length 50m Motor cable 8x1,5mm² Length 10m Length 50m UPE € 43,41 157,20 48,59 183,06 66,82 245,67 3.3.2 Motor cable 2,5mm² - sold by the ring Order number HTG:61 88 600 0125 HTG:61 88 600 0126 HTG:61 88 600 0127 HTG:61 88 600 0128 HTG:61 88 600 0131 HTG:61 88 600 0132 Edition 01/2012 Page 21 Description Motor cable 4x2,5mm² Length 10m Length 50m Motor cable 6x2,5mm² Length 10m Length 50m Motor cable 8x2,5mm² Length 10m Length 50m UPE € 47,24 176,38 56,30 221,57 125,47 515,49 M200D Supplementary products 3.4 Set of connector for motor connection cable, on the side of the motor starter (M200D) Motor – connection cable with HanQ 8/0 connector Order number HTG:61 83 401 0065 HTG:61 83 401 0066 Edition 01/2012 Page 22 Description Set of connectors for motor cable for connection to M200D Hood, outgoing circuit side entry, UL Male insert for Han Q8/0 Gland for cable size 9 –13 mm 8 male contacts 1,5mm² 8 male contacts 2,5mm² UPE € 9,05 9,05 M200D Supplementary products 3.5 Sets of connectors on the side of the motor Han 10E Socket (Motor) Female insert and star bridge Motor with HanDrive Order number HTG:61 83 401 0047 HTG:61 83 401 0067 Edition 01/2012 Page 23 Description Set of connectors for motor cable for connection to Motor Star jumper Hood Female insert for Han 10E, UL Gland for cable size 9 – 13 mm 7 female contacts 1,5mm² 11 – 15,5 mm 7 female contacts 2,5mm² UPE € 17,92 17,92 M200D Supplementary products 4 Accessories 4.1 Set of connectors for power bus switching cabinet / subdistributor Set of connectors HanQ 4/2 Hood Male insert Mounting case HanQ 4/2 Female insert Energy bus connector Male Energy bus connector female Order number HTG: on request HTG:61 88 201 0051 Order number HTG:61 83 401 0116 HTG:61 83 401 0117 HTG:61 83 401 0118 HTG:61 83 401 0119 Edition 01/2012 Page 24 Description Mounting case consisting of Housing Set of female insert for Han Q4/2 5 female contacts 4mm² 5 female contacts 6mm² Description Set of connectors Hood, (with bracket) outgoing circuit top entry Male insert for Han Q4/2, UL Gland for cable size 12,5 – 16,5 mm 5 male contacts 4mm² 5 male contacts 6mm² Set of connectors Hood, (with bracket) outgoing circuit side entry Male insert for Han Q4/2, UL Gland for cable size 12,5 – 16,5 mm 5 male contacts 4mm² 12,5 – 16,5 mm 5 male contacts 6mm² UPE € 70,64 UPE € 14,00 14,00 15,58 15,58 M200D Supplementary products 4.2 Protective cover Order number HTG:09 12 008 5407 HTG:61 83 401 0070 HTG:09 30 010 5432 4.3 UPE € Description Crimping tool for Han Q4/2 for Cross sections from 1,5mm² up to 6mm² Crimping tool for Han Q8/0 for Cross sections from 1,5mm² up to 6mm² Crimping tool for Han 10e for Cross sections from 1,5mm² up to 2,5mm² UPE € 6,39 5,17 22,92 Crimping tool Order number HTG:09 99 000 0303 HTG:09 99 000 0110 HTG:09 99 000 0110 4.4 Description Protection cover Han Q4/2 and Q8/0 for housing, UL Protection cover with bracket for Han Q4/2 and Q8/0 Hood/Power T Protection cover Han 10e for Hood (with bracket), UL 307,06 382,52 382,52 Dismantle tool for male and female inserts Order number HTG:09 99 000 0305 HTG:09 99 000 0319 HTG:09 99 000 0319 Edition 01/2012 Page 25 Description Dismantle tool for Han Q4/2 for Cross sections from 1,5mm² up to 6mm² Dismantle tool for Han Q8/0 for Cross sections from 1,5mm² up to 6mm² Dismantle tool for Han 10e for Cross sections from 1,5mm² up to 2,5mm² UPE € 9,69 17,19 17,19 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com SIRIUS M200D Ergänzungsprodukte (Supplementary products) Technische Daten / Technical Data Seite 27 Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 1.1 Energie T-Klemmverbinder / Energy T-terminal connector Han Power-S 1x Han Q4/2-F for wire gauge 4-6mm² Artikel-Nr. Querschnitt Part No. Wire gauge HTG: 61 88 201 0500 2,5-4mm² HTG: 61 88 201 0501 4-6mm² PIN h=55 1 L1 2 L2 3 L3 4 N 11 - 12 PE 2,5m Kabelspezifikation Kapitel 1.4--1.6 cable specification chapter 1.4--1.6 h=55 Han Power-S PIN Y Querschnitt Wire gauge 1 L1 HTG:61 88 201 0502 5x2,5mm² 2 L2 HTG:61 88 201 0503 5x4mm² 3 L3 HTG:61 88 201 0504 5x6mm² 4 N 11 - 12 PE Seite 28 Artikel-Nr. Part No. Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 1.1 Energie T-Klemmverbinder / Energy T-terminal connector Artikel-Nr. Kabel VPE/Satz Part No. Cable Packaging unit HTG: 61 83 401 0200 10-13mm 2 HTG: 61 83 401 0201 13-16mm 2 HTG: 61 83 401 0202 16-19mm 2 HTG: 61 83 401 0203 19-22mm 2 HTG: 61 83 401 0204 Blindstopfen 1 Blind grommet Dichtung sealing Seite 29 Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 1.2 Energie T-Verbinder für Powerbus max. 25mm² Power T-connector for power max. 25mm² Artikel-Nr. Querschnitt Part No. Wire gauge HTG:61 88 201 0181 4-6mm² PIN Energie T-Verbinder Power T-Connector h=60 Lochbild 138 1 L1 2 L2 3 L3 4 N 11 - 12 - 74 PE 151 1.3 Energie Doppel-T-Klemmverbinder Power double T-terminal connector Doppel-T-Klemmverbinder Artikel-Nr. Querschnitt Part No. Wire gauge HTG:61 88 202 0770 4-6mm² 2x Han Q4/2-F for wire gauge 4-6mm² PIN h=55 1 L1 2 L2 3 L3 4 N 11 - 12 PE Seite 30 Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 1.3 Energie Doppel-T-Klemmverbinder Power double T-terminal connector Artikel-Nr. Kabel VPE/Satz Part No. Cable Packaging unit HTG:09 12 000 9970SI 10-13mm 2 HTG:09 12 000 9971SI 13-16mm 2 HTG:09 12 000 9972SI 16-19mm 2 HTG:09 12 000 9973SI 19-22mm 2 HTG:09 12 000 9974SI Blindstopfen 1 Blind grommet Dichtung sealing Seite 31 Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 1.4.1 Energiebus- und Einspeiseleitungen (Ringware) 2,5mm² Power bus and Supply cable (sold by ring) 2,5mm² Anwendung Artikel-Nr. Länge VPE Part No. length Packaging unit 5 x 2,5mm² Verwendung als Energie- oder Verbindungsleitung, HTG:61 88 600 0101 50m 1 HTG:61 88 600 0102 100m 1 >100m 1 auf Anfrage on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 32 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 1.4.2 Energiebus- und Einspeiseleitungen (Ringware) 4mm² Power bus and Supply cable (sold by ring) 4mm² Artikel-Nr. Länge VPE Part No. length Packaging unit 5 x 4mm² Anwendung HTG:61 88 600 0107 50m 1 HTG:61 88 600 0108 100m 1 >100m 1 auf Anfrage Verwendung als Energie- oder Verbindungsleitung, on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 33 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 1.4.3 Energiebus- und Einspeiseleitungen (Ringware) 6mm² Power bus and Supply cable (sold by ring) 6mm² Anwendung Artikel-Nr. Länge VPE Part No. length Packaging unit 5 x 6mm² Verwendung als Energie- oder Verbindungsleitung, HTG:61 88 600 0113 50m 1 HTG:61 88 600 0114 100m 1 >100m 1 auf Anfrage on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 34 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 2.1 Energie Einspeiseleitung für Motorstarter konfektioniert Power cables for motor starter prefabricated 4 x 2,5mm² 4 x 4,0mm² Artikel-Nr. Länge Part No. length HTG:61 88 202 0400 1,5m HTG:61 88 202 0401 3,0m HTG:61 88 202 0402 5,0m HTG:61 88 202 0403 10,0m Artikel-Nr. Länge Part No. length HTG:61 88 202 0404 1,5m HTG:61 88 202 0405 3,0m HTG:61 88 202 0406 5,0m HTG:61 88 202 0407 10,0m PIN X Y 1 L1 L1 Artikel-Nr. Länge 2 L2 L2 Part No. length 3 L3 L3 HTG:61 88 202 0408 1,5m PE PE HTG:61 88 202 0409 3,0m HTG:61 88 202 0410 5,0m HTG:61 88 202 0411 10,0m 4 x 6,0mm² H05VV5-F Elektrische und technische Daten Aufbau/design /electrical and technical data Variable Längen auf Anfrage Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 35 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 2.1 Energie Einspeiseleitung mit N-Leiter für Motorstarter konfektioniert Power cables with N-conductor for motor starter prefabricated 5 x 2,5mm² 5 x 4,0mm² Artikel-Nr. Länge Part No. length HTG:61 88 202 0693 1,5m HTG:61 88 202 0694 3,0m HTG:61 88 202 0695 5,0m HTG:61 88 202 0696 10,0m Artikel-Nr. Länge Part No. length HTG:61 88 202 0697 1,5m HTG:61 88 202 0698 3,0m HTG:61 88 202 0699 5,0m HTG:61 88 202 0700 10,0m PIN X Y 1 L1 L1 Artikel-Nr. Länge 2 L2 L2 Part No. length 3 L3 L3 HTG:61 88 202 0701 1,5m 4 N N HTG:61 88 202 0702 3,0m PE PE HTG:61 88 202 0703 5,0m HTG:61 88 202 0704 10,0m 5 x 6,0mm² H05VV5-F Elektrische und technische Daten Aufbau/design /electrical and technical data Variable Längen auf Anfrage Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 5G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 5G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 36 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 2.2 Energie Einspeiseleitung für Motorstarter, einseitig konfektioniert / Power cables for motor starter, one-sided prefabricated 4 x 2,5mm² 4 x 4,0mm² Ader Artikel-Nr. Länge Part No. length HTG:61 88 201 0192 1,5m HTG:61 88 201 0193 3,0m HTG:61 88 201 0194 5,0m HTG:61 88 201 0195 10,0m Artikel-Nr. Länge Part No. length HTG:61 88 201 0196 1,5m HTG:61 88 201 0197 3,0m HTG:61 88 201 0198 5,0m HTG:61 88 201 0199 10,0m PIN X 1 L1 1 2 L2 2 Artikel-Nr. Länge Part No. length 3 L3 3 HTG:61 88 201 0200 1,5m PE gn/ge HTG:61 88 201 0201 3,0m HTG:61 88 201 0202 5,0m HTG:61 88 201 0203 10,0m core 4 x 6,0mm² ye/gn H05VV5-F Elektrische und technische Daten Aufbau/design /electrical and technical data Variable Längen auf Anfrage Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 37 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 2.2 Energie Einspeiseleitung mit N-Leiter für Motorstarter, einseitig Power cables with N-Conductor for motor starter, one-sided prefabricated 5 x 2,5mm² 5 x 4,0mm² Ader Artikel-Nr. Länge Part No. length HTG:61 88 201 0458 1,5m HTG:61 88 201 0459 3,0m HTG:61 88 201 0460 5,0m HTG:61 88 201 0461 10,0m Artikel-Nr. Länge Part No. length HTG:61 88 201 0462 1,5m HTG:61 88 201 0463 3,0m HTG:61 88 201 0464 5,0m HTG:61 88 201 0465 10,0m PIN X 1 L1 1 2 L2 2 Artikel-Nr. Länge Part No. length 3 L3 3 HTG:61 88 201 0466 1,5m 4 N 4 HTG:61 88 201 0467 3,0m HTG:61 88 201 0468 5,0m HTG:61 88 201 0469 10,0m PE core 5 x 6,0mm² gn/ge ye/gn H05VV5-F Elektrische und technische Daten Aufbau/design /electrical and technical data Variable Längen auf Anfrage Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 5G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 5G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 38 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 2.3.1 Energie-Einspeiseleitungen (Ringware) 2,5mm² Power bus cable (sold by ring) 2,5mm² Anwendung Artikel-Nr. Länge VPE Part No. length Packaging unit 4 x 2,5mm² Verwendung als Energie- oder Verbindungsleitung, HTG:61 88 600 0115 50m 1 HTG:61 88 600 0116 100m 1 >100m 1 auf Anfrage on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 39 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 2.3.2 Energie-Einspeiseleitungen (Ringware) 4mm² Power bus cable (sold by ring) 4mm² Artikel-Nr. Länge VPE Part No. length Packaging unit 4 x 4mm² Anwendung HTG:61 88 600 0117 50m 1 HTG:61 88 600 0118 100m 1 >100m 1 auf Anfrage Verwendung als Energie- oder Verbindungsleitung, on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 40 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 2.3.3 Energie-Einspeiseleitungen (RIngware) 6mm² Power bus cable (sold by ring) 6mm² Anwendung Artikel-Nr. Länge VPE Part No. length Packaging unit 4 x 6mm² Verwendung als Energie- oder Verbindungsleitung, HTG:61 88 600 0119 50m 1 HTG:61 88 600 0120 100m 1 >100m 1 auf Anfrage on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 41 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 2.4 Steckersatz für Energie-Einspeiseleitung / Connector set for power cable Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black Stift-Stecker Han Q8/0-Kg-16 Kupplungsgehäuse hood cable to cable Male insert Dichteinsatz seal insert Han Q4/2-M-c Stifteinsatz male insert Artikel-Nr. Querschnitt Dichteinsatz Part No. Wire gauge seal insert HTG:61 04 401 0556 4,0mm² HTG:61 04 401 0545 6,0mm² 11,5-15,5 weiß/white 12-16,5 natur/natur 5x Han C Stiftkontakt, versilbert Han C male contact, silver plated Han Q8/0-Tg-16 Tüllengehäuse hood side-entry Han Q4/2-F-c Buchseneinsatz female insert Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black Dichteinsatz Buchsen-Stecker Female insert seal insert 5x Han C Buchsentkontakt, versilbert Han C female contact, silver plated Artikel-Nr. Querschnitt Dichteinsatz Part No. Wire gauge seal insert HTG:61 04 401 0550 4,0mm² HTG:61 04 401 0502 6,0mm² 11,5-15,5 weiß/white 12-16,5 natur/natur Crimpwerkzeug / Crimping tool HTG:09 99 000 0110 Han D Han E Han C 1,5-4mm² HTG:09 99 000 0303 Han C 4-6mm² Seite 42 Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.1.1 Motorleitung für Motoren in Sternschaltung, ohne Bremse, / Motor cable for motors in star ohne Thermistor, konfektioniert connection, without brake, without thermistor, prefabricated Ansicht X View X Y PIN L1 1 Ansicht Y Y X View Y L1 2 - L2 3 L3 L3 4 - - 5 - - 6 - 7 L2 8 - 9 - - 10 - - PE PE 4 x 1,5mm² Brücke bridge 4 x 2,5mm² Artikel-Nr. Länge Part No. length HTG:61 88 202 0424 1,5m HTG:61 88 202 0425 3,0m HTG:61 88 202 0426 5,0m Artikel-Nr. Länge Part No. length HTG:61 88 202 0427 1,5m HTG:61 88 202 0428 3,0m HTG:61 88 202 0429 5,0m H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 43 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.1.2 Motorleitung für Motoren in Sternschaltung, mit Bremse AC400V / / Motor cable for motor in star DC180V, ohne Thermistor, konfektioniert connection with brake, without thermistor, prefabricated Ansicht X View X Y Ansicht Y X PIN L1 1 View Y Y L1 2 - L2 3 L3 L3 4 Bremse Bremse 5 - Bremse 6 Bremse 7 L2 8 - 9 - - 10 - - PE PE 6 x 1,5mm² Brücke bridge 6 x 2,5mm² Artikel-Nr. Länge Part No. length HTG:61 88 202 0607 1,5m HTG:61 88 202 0608 3,0m HTG:61 88 202 0609 5,0m Artikel-Nr. Länge Part No. length HTG:61 88 202 0610 1,5m HTG:61 88 202 0611 3,0m HTG:61 88 202 0612 5,0m H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 44 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.1.2 Motorleitung für Motoren in Sternschaltung, mit Bremse 230V, / Motor cable for motor in star ohne Thermistor, konfektioniert connection with brake 230V, without thermistor, prefabricated Ansicht X View X Y Ansicht Y X PIN L1 1 View Y Y L1 2 Bremse L2 3 L3 L3 4 Bremse Bremse 5 - Bremse 6 - 7 L2 8 - 9 - - 10 - - PE PE 6 x 1,5mm² Brücke bridge 6 x 2,5mm² Artikel-Nr. Länge Part No. length HTG:61 88 202 0705 1,5m HTG:61 88 202 0706 3,0m HTG:61 88 202 0707 5,0m Artikel-Nr. Länge Part No. length HTG:61 88 202 0708 1,5m HTG:61 88 202 0709 3,0m HTG:61 88 202 0710 5,0m H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 45 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.1.3 Motorleitung für Motoren in Sternschaltung, mit Bremse AC400V / / Motor cable for motor in star DC180V, mit Thermistor, konfektioniert connection with brake, with thermistor, prefabricated Ansicht X View X Y Ansicht Y X PIN U 1 View Y Y U 2 - W 3 W V 4 Bremse Bremse 5 Temp. Bremse 6 Bremse 7 V 8 Temp. 9 - Temp. 10 - Temp. PE PE 8 x 1,5mm² Brücke bridge 8 x 2,5mm² Artikel-Nr. Länge Part No. length HTG:61 88 202 0682 1,5m HTG:61 88 202 0683 3,0m HTG:61 88 202 0684 5,0m Artikel-Nr. Länge Part No. length HTG:61 88 202 0685 1,5m HTG:61 88 202 0686 3,0m HTG:61 88 202 0687 5,0m H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 46 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.1.3 Motorleitung für Motoren in Sternschaltung, mit Bremse 230V, / Motor cable for motor in star mit Thermistor, konfektioniert connection with brake 230V, with thermistor, prefabricated Ansicht X View X Y Ansicht Y X PIN U 1 View Y Y U 2 Bremse W 3 W V 4 Bremse Bremse 5 Temp. Bremse 6 - 7 V 8 Temp. 9 - Temp. 10 - Temp. PE PE 8 x 1,5mm² Brücke bridge 8 x 2,5mm² Artikel-Nr. Länge Part No. length HTG:61 88 202 0711 1,5m HTG:61 88 202 0712 3,0m HTG:61 88 202 0713 5,0m Artikel-Nr. Länge Part No. length HTG:61 88 202 0714 1,5m HTG:61 88 202 0715 3,0m HTG:61 88 202 0716 5,0m H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 47 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.2.1 Motorleitung für Motoren in Sternschaltung, ohne Bremse, ohne Thermistor, einseitig konfektioniert / Motor cable for motors in star connection, without brake, w/o thermistor, one-sided prefabricated Ansicht X View X PIN X Ader core 1 L1 1 2 - - 3 L3 3 4 - - 5 - - 6 - - 7 L2 2 PE gn/ge 4 x 1,5mm² 8 4 x 2,5mm² ye/gn Artikel-Nr. Länge Part No. length HTG:61 88 201 0211 1,5m HTG:61 88 201 0212 3,0m HTG:61 88 201 0213 5,0m Artikel-Nr. Länge Part No. length HTG:61 88 201 0214 1,5m HTG:61 88 201 0215 3,0m HTG:61 88 201 0216 5,0m H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 48 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.2.2 Motorleitung für Motoren in Sternschaltung, mit Bremse AC400V / DC180V, ohne Thermistor, einseitig konfektioniert / Motor cable for motors in star connection, with brake, w/o thermistor, one-sided prefabricated Ansicht X View X PIN X Ader core 1 L1 1 2 - - 3 L3 3 4 Bremse 4 5 - - 6 Bremse 5 7 L2 2 PE gn/ge 6 x 1,5mm² 8 6 x 2,5mm² ye/gn Artikel-Nr. Länge Part No. length HTG:61 88 201 0218 1,5m HTG:61 88 201 0219 3,0m HTG:61 88 201 0220 5,0m Artikel-Nr. Länge Part No. length HTG:61 88 201 0221 1,5m HTG:61 88 201 0222 3,0m HTG:61 88 201 0223 5,0m H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 49 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.2.2 Motorleitung für Motoren in Sternschaltung, mit Bremse 230V, ohne Thermistor, einseitig konfektioniert / Motor cable for motors in star connection, with brake 230V, w/o thermistor, one-sided prefabricated Ansicht X View X PIN X Ader core 1 L1 1 2 Bremse 5 3 L3 3 4 Bremse 4 5 - - 6 - - 7 L2 2 PE gn/ge 6 x 1,5mm² 8 6 x 2,5mm² ye/gn Artikel-Nr. Länge Part No. length HTG:61 88 201 0470 1,5m HTG:61 88 201 0471 3,0m HTG:61 88 201 0472 5,0m Artikel-Nr. Länge Part No. length HTG:61 88 201 0473 1,5m HTG:61 88 201 0474 3,0m HTG:61 88 201 0475 5,0m H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 50 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.2.3 Motorleitung für Motoren in Sternschaltung, mit Bremse AC400V / DC180V, mit Thermistor, einseitig konfektioniert / Motor cable for motors in star connection, with brake, with thermistor, one-sided prefabricated Ansicht X View X PIN X Ader core Artikel-Nr. Länge Part No. length HTG:61 88 201 0452 1,5m HTG:61 88 201 0453 3,0m HTG:61 88 201 0454 5,0m 1 L1 1 2 - - 3 L3 3 4 Bremse 4 5 Temp. 6 6 Bremse 5 7 L2 2 HTG:61 88 201 0455 1,5m 8 Temp. 7 HTG:61 88 201 0456 3,0m PE gn/ge HTG:61 88 201 0457 5,0m 8 x 1,5mm² 8 x 2,5mm² ye/gn Artikel-Nr. Länge Part No. length H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 51 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.2.3 Motorleitung für Motoren in Sternschaltung, mit Bremse 230V, mit Thermistor, einseitig konfektioniert / Motor cable for motors in star connection, with brake 230V, with thermistor, one-sided prefabricated Ansicht X View X PIN X Ader core Artikel-Nr. Länge Part No. length HTG:61 88 201 0476 1,5m HTG:61 88 201 0477 3,0m HTG:61 88 201 0478 5,0m 1 L1 1 2 Bremse 5 3 L3 3 4 Bremse 4 5 Temp. 6 6 - - 7 L2 2 HTG:61 88 201 0479 1,5m 8 Temp. 7 HTG:61 88 201 0480 3,0m PE gn/ge HTG:61 88 201 0481 5,0m 8 x 1,5mm² 8 x 2,5mm² ye/gn Artikel-Nr. Länge Part No. length H05VV5-F Elektrische und technische Daten Variable Längen auf Anfrage Aufbau/design /electrical and technical data Variable lengths on request -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km HD 383 CLASS 5 /leakage resistance 300/500V mind. 2000V Werkstoff: -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: /green-yellow protective conductor /temperature range -Lagenverseilung bewegt /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 -Ölbeständig / oil-resistant Seite 52 Gehäuse/housing ca. 15x Kabeldurchmesser approx. 15x cable diam PC /material Verriegelungselement: PA /interlock element Überwurfmutter PG 16 - 5°C bis +70°C /lock nut Werkstoff: -30°C bis +70°C PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Ausgabe 11/2009 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.3.1 Motorleitung (Meterware) 1,5mm² Motor cable (sold by meter) 1,5mm² Anwendung 4 x 1,5mm² Verwendung als Energie- oder Verbindungsleitung, Artikel-Nr. Länge Part No. length HTG:61 88 600 0121 10m HTG:61 88 600 0122 50m auf Anfrage >50m on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 53 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.3.1 Motorleitung (Meterware) 1,5mm² Motor cable (sold by meter) 1,5mm² Anwendung 6 x 1,5mm² Verwendung als Energie- oder Verbindungsleitung, Artikel-Nr. Länge Part No. length HTG:61 88 600 0123 10m HTG:61 88 600 0124 50m auf Anfrage on request >50m als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 54 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.3.1 Motorleitung (Meterware) 1,5mm² Motor cable (sold by meter) 1,5mm² Anwendung 8 x 1,5mm² Verwendung als Energie- oder Verbindungsleitung, Artikel-Nr. Länge Part No. length HTG:61 88 600 0129 10m HTG:61 88 600 0130 50m auf Anfrage on request >50m als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 55 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.3.2 Motorleitung (Meterware) 2,5mm² Motor cable (sold by meter) 2,5mm² Anwendung 4 x 2,5mm² Verwendung als Energie- oder Verbindungsleitung, Artikel-Nr. Länge Part No. length HTG:61 88 600 0125 10m HTG:61 88 600 0126 50m auf Anfrage >50m on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 56 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.3.2 Motorleitung (Meterware) 2,5mm² Motor cable (sold by meter) 2,5mm² 6 x 2,5mm² Anwendung Artikel-Nr. Länge Part No. length HTG:61 88 600 0127 10m HTG:61 88 600 0128 50m auf Anfrage on request >50m Verwendung als Energie- oder Verbindungsleitung, als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 57 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.3.2 Motorleitung (Meterware) 2,5mm² Motor cable (sold by meter) 2,5mm² 8 x 2,5mm² Anwendung Artikel-Nr. Länge Part No. length HTG:61 88 600 0131 10m HTG:61 88 600 0132 50m auf Anfrage on request >50m Verwendung als Energie- oder Verbindungsleitung, als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/design Elektrische und technische Daten /electrical and technical date -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km Biegeradius / bending radius : bzw. IEC 60228 cl.5 approx. 7,5x cable diam /strand structure according to VDE 0295, Temperaturbereich / temperature range : class 5 + IEC 60228 class 5 + bewegt -Adern spezial PVC - 5°C bis +70°C /moved /core insulation: special PVC unbewegt - schwarze Adern mit fortl, weißem -30°C bis +70°C /unmoved Ziffernaufdruck / black cores with white Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B printed consecutive number coding und IEC 332-1 / fire performence according to IEC 60332-1 to -Schutzleiter grüngelb DIN VDE 0472 part 804 /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 58 ca. 15x Kabeldurchmesser Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 3.4 Steckersätze für Motor-Anschlussleitung auf Motorstarterseite, Set of connectors for motor connection cable on the side of the motor starter Dichteinsatz Han Q8/0-Tg-16 Tüllengehäuse seal insert Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black hood side-entry Stift-Stecker Male insert Han Q4/2-M-c Stifteinsatz male insert Artikel-Nr. Querschnitt Dichteinsatz Part No. Wire gauge seal insert HTG:61 83 401 0065 1,5mm² 9-13 rot/red HTG:61 83 401 0066 2,5mm² 11,5-15,5 weiß/white 6x Han E-Stiftkontakt, versilbert Han E male contact, silver plated 3.5 Steckersätze für Motor-Anschlussleitung auf Motorstarterseite, ohne Schutzbeschaltung / Set of connectors for motor connection cable on the side of the motor , without EMC protective circuit Dichteinsatz seal insert Verschraubung cable gland Han 10B-gg-R-M20 Tüllengehäuse hood top-entry Han 10E-F-c Buchseneinsatz Buchsen-Stecker female insert Female insert Artikel-Nr. Querschnitt Dichteinsatz Part No. Wire gauge seal insert HTG:61 83 401 0047 1,5mm² 9-13 rot/red HTG:61 83 401 0067 2,5mm² 11,5-15,5 weiß/white 7x Han E-Buchsenkontakt, versilbert Han E female contact, silver plated Seite 59 Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 4.1 Steckersätze für Energiebus Anschluss Schaltschrank / Unterverteiler / Set of connectors for power bus switching cabinet/subdistributor Überwurfmutter Pg 16 Ku, sw Han Q8/0-kg-16 Kupplungsgehäuse Dichteinsatz hoods cable to cable seal insert connecting nut PG16, thermoplastic, black Buchsen-Stecker Female insert Schaltschrank Innenseite Artikel-Nr. Querschnitt inside control cabinet Part No. Wire gauge HTG:61 88 201 0051 6mm² Schaltschrank Außenseite outside control cabinet Baugröße Han 24B Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black Dichteinsatz seal insert Han Q8/0-Kg-16 Kupplungsgehäuse hood thermoplastic Han Q4/2-M-c Stifteinsatz male insert Stift-Stecker Male insert 5x Han C-Stiftkontakt, versilbert Han C male contact, silver plated Seite 60 Artikel-Nr. Querschnitt Dichteinsatz Part No. Wire gauge seal insert HTG:61 83 401 0116 4mm² 12,5-16,5 grau/grey HTG:61 83 401 0117 6mm² 12,5-16,5 grau/grey Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 4.1 Steckersätze für Energiebus Anschluss Schaltschrank / Unterverteiler / Set of connectors for power bus switching cabinet/subdistributor Han Q8/0-Kg-16 Kupplungsgehäuse Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black hoods cable to cable Han Q4/2-M-c Stifteinsatz male insert Dichteinsatz seal insert Stift-Stecker Male insert 5x Han C-Stiftkontakt, versilbert Han C male contact, silver plated Seite 61 Artikel-Nr. Querschnitt Dichteinsatz Part No. Wire gauge seal insert HTG:61 83 401 0118 4mm² 12,5-16,5 grau/grey HTG:61 83 401 0119 6mm² 12,5-16,5 grau/grey Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 4.2 Verschlußkappen / Protection covers (if there is no plug used) Han Q4/2 und Q 8/2-AK-QB,schwarz Protection cover for male insert, black Artikel-Nr. Part No. HTG: 09 12 008 5407 Han Q Abdeckkappe mit Verriegelungsbügel Han Q protection cover Artikel-Nr. Part No. HTG: 61 83 401 0070 Han 10B-AK-LB-Dichtung, Metallabdeckkappe metal cover Artikel-Nr. Part No. HTG: 09 30 010 5432 Seite 62 Ausgabe 11/2009 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 4.3 Crimpzangen / Crimping tools Crimpzange für Han Q 4/2 crimping tool for Han Q4/2 Artikel-Nr. Querschnitt Part No. Wire gauge HTG:09 99 000 0303 Artikel-Nr. Querschnitt Part No. Wire gauge HTG:09 99 000 0110 Crimpzange für Han Q 8/0 / Han 10E crimping tool for Han Q 8/0 / Han 10E Seite 63 Ausgabe 11/2009 4mm²-6mm² 0,5mm²-4mm² HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com M200D 4.4 Demontagewerkzeuge für Stifte und Buchsen Dismantle tools for male and female inserts Demontagewerkzeug für Han Q 4/2 Removal tool for Han Q 4/2 Artikel-Nr. Querschnitt Part No. Wire gauge HTG:09 99 000 0305 Artikel-Nr. Querschnitt Part No. Wire gauge HTG:09 99 000 0319 Demontagewerkzeug für Han Q 8/0 / Han 10E Removal tool for Han Q 8/0 / Han 10E Seite 64 Ausgabe 11/2009 4mm²-6mm² 0,5mm²-4mm² HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com Bestell-Nummern-Verzeichnis List of part numbers M200D Artikelnummer Kapitel Artikelnummer Part No. Chapter Part No. Chapter HTG:61 83 401 0200 HTG:61 83 401 0201 HTG:61 83 401 0202 HTG:61 83 401 0203 HTG:61 83 401 0204 HTG:61 88 201 0502 HTG:61 88 201 0503 HTG:61 88 201 0504 HTG:61 88 201 0500 HTG:61 88 201 0501 HTG:61 88 202 0770 HTG:09 12 008 5407 HTG:09 30 010 5432 HTG:09 99 000 0110 HTG:09 99 000 0303 HTG:09 99 000 0305 HTG:09 99 000 0319 HTG:61 04 401 0502 HTG:61 04 401 0545 HTG:61 04 401 0550 HTG:61 04 401 0556 HTG:61 83 401 0047 HTG:61 83 401 0065 HTG:61 83 401 0066 HTG:61 83 401 0067 HTG:61 83 401 0070 HTG:61 83 401 0116 HTG:61 83 401 0117 HTG:61 83 401 0118 HTG:61 83 401 0119 HTG:61 88 201 0051 HTG:61 88 201 0181 HTG:61 88 201 0192 HTG:61 88 201 0193 HTG:61 88 201 0194 HTG:61 88 201 0195 HTG:61 88 201 0196 HTG:61 88 201 0197 HTG:61 88 201 0198 HTG:61 88 201 0199 HTG:61 88 201 0200 2.1.3 2.1.3 2.1.3 3.1.1.1 3.1.1.1 3.1.1.1 3.1.1.2 3.1.1.2 3.1.1.2 3.1.1.2 3.3.1.1 3.3.1.1 3.3.1.1 3.3.1.2 3.3.1.2 3.3.1.2 3.1.3.1 3.1.3.1 3.1.3.1 3.1.3.2 3.1.3.2 3.1.3.2 1.4.1 1.4.1 1.4.2 1.4.2 1.4.3 1.4.3 2.3.1 2.3.1 2.3.2 2.3.2 2.2.1 2.2.1 2.2.1 2.2.1 2.2.2 2.2.2 2.2.2 2.2.2 2.2.3 HTG:61 88 201 0201 HTG:61 88 201 0202 HTG:61 88 201 0203 HTG:61 88 201 0211 HTG:61 88 201 0212 HTG:61 88 201 0213 HTG:61 88 201 0214 HTG:61 88 201 0215 HTG:61 88 201 0216 HTG:61 88 201 0218 HTG:61 88 201 0219 HTG:61 88 201 0220 HTG:61 88 201 0221 HTG:61 88 201 0222 HTG:61 88 201 0223 HTG:61 88 201 0452 HTG:61 88 201 0453 HTG:61 88 201 0454 HTG:61 88 201 0455 HTG:61 88 201 0456 HTG:61 88 201 0457 HTG:61 88 201 0458 HTG:61 88 201 0459 HTG:61 88 201 0460 HTG:61 88 201 0461 HTG:61 88 201 0462 HTG:61 88 201 0463 HTG:61 88 201 0464 HTG:61 88 201 0465 HTG:61 88 201 0466 HTG:61 88 201 0467 HTG:61 88 201 0468 HTG:61 88 201 0469 HTG:61 88 201 0470 HTG:61 88 201 0471 HTG:61 88 201 0472 HTG:61 88 201 0473 HTG:61 88 201 0474 HTG:61 88 201 0475 HTG:61 88 201 0476 HTG:61 88 201 0477 2.2.3 2.2.3 2.2.3 3.2.1.1 3.2.1.1 3.2.1.1 3.2.1.2 3.2.1.2 3.2.1.2 3.2.2.1 3.2.2.1 3.2.2.1 3.2.2.2 3.2.2.2 3.2.2.2 3.2.3.1 3.2.3.1 3.2.3.1 3.2.3.2 3.2.3.2 3.2.3.2 2.2.1 2.2.1 2.2.1 2.2.1 2.2.2 2.2.2 2.2.2 2.2.2 2.2.3 2.2.3 2.2.3 2.2.3 3.2.2.1 3.2.2.1 3.2.2.1 3.2.2.2 3.2.2.2 3.2.2.2 3.2.3.1 3.2.3.1 Seite 65 Ausgabe 11/2009 Kapitel HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com Bestell-Nummern-Verzeichnis List of part numbers M200D Artikelnummer Kapitel Artikelnummer Part No. Chapter Part No. Chapter HTG:61 88 201 0478 HTG:61 88 201 0479 HTG:61 88 201 0480 HTG:61 88 201 0481 HTG:61 88 202 0400 HTG:61 88 202 0401 HTG:61 88 202 0402 HTG:61 88 202 0403 HTG:61 88 202 0404 HTG:61 88 202 0405 HTG:61 88 202 0406 HTG:61 88 202 0407 HTG:61 88 202 0408 HTG:61 88 202 0409 HTG:61 88 202 0410 HTG:61 88 202 0411 HTG:61 88 202 0424 HTG:61 88 202 0425 HTG:61 88 202 0426 HTG:61 88 202 0427 HTG:61 88 202 0428 HTG:61 88 202 0429 HTG:61 88 202 0607 HTG:61 88 202 0608 HTG:61 88 202 0609 HTG:61 88 202 0610 HTG:61 88 202 0611 HTG:61 88 202 0612 HTG:61 88 202 0682 HTG:61 88 202 0683 HTG:61 88 202 0684 HTG:61 88 202 0685 HTG:61 88 202 0686 HTG:61 88 202 0687 HTG:61 88 202 0693 HTG:61 88 202 0694 HTG:61 88 202 0695 HTG:61 88 202 0696 HTG:61 88 202 0697 HTG:61 88 202 0698 HTG:61 88 202 0699 3.2.3.1 3.2.3.2 3.2.3.2 3.2.3.2 2.1 2.1 2.1 2.1 2.1.2 2.1.2 2.1.2 2.1.2 2.1.3 2.1.3 2.1.3 2.1.3 3.1.1.1 3.1.1.1 3.1.1.1 3.1.1.2 3.1.1.2 3.1.1.2 3.3.1.1 3.3.1.1 3.3.1.1 3.3.1.2 3.3.1.2 3.3.1.2 3.1.3.1 3.1.3.1 3.1.3.1 3.1.3.2 3.1.3.2 3.1.3.2 2.1 2.1 2.1 2.1 2.1.2 2.1.2 2.1.2 HTG:61 88 202 0700 HTG:61 88 202 0701 HTG:61 88 202 0702 HTG:61 88 202 0703 HTG:61 88 202 0704 HTG:61 88 202 0705 HTG:61 88 202 0706 HTG:61 88 202 0707 HTG:61 88 202 0708 HTG:61 88 202 0709 HTG:61 88 202 0710 HTG:61 88 202 0711 HTG:61 88 202 0712 HTG:61 88 202 0713 HTG:61 88 202 0714 HTG:61 88 202 0715 HTG:61 88 202 0716 HTG:61 88 600 0101 HTG:61 88 600 0102 HTG:61 88 600 0107 HTG:61 88 600 0108 HTG:61 88 600 0113 HTG:61 88 600 0114 HTG:61 88 600 0115 HTG:61 88 600 0116 HTG:61 88 600 0117 HTG:61 88 600 0118 HTG:61 88 600 0119 HTG:61 88 600 0120 HTG:61 88 600 0121 HTG:61 88 600 0122 HTG:61 88 600 0123 HTG:61 88 600 0124 HTG:61 88 600 0125 HTG:61 88 600 0126 HTG:61 88 600 0127 HTG:61 88 600 0128 HTG:61 88 600 0129 HTG:61 88 600 0130 HTG:61 88 600 0131 HTG:61 88 600 0132 2.1.2 2.1.3 2.1.3 2.1.3 2.1.3 3.3.1.1 3.3.1.1 3.3.1.1 3.3.1.2 3.3.1.2 3.3.1.2 3.1.3.1 3.1.3.1 3.1.3.1 3.1.3.2 3.1.3.2 3.1.3.2 1.4.1 1.4.1 1.4.2 1.4.2 1.4.3 1.4.3 2.3.1 2.3.1 2.3.2 2.3.2 2.3.3 2.3.3 3.3.1 3.3.1 3.3.1 3.3.1 3.3.2 3.3.2 3.3.2 3.3.2 3.3.1 3.3.1 3.3.2 3.3.2 Seite 66 Ausgabe 11/2009 Kapitel HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 Fax: (0571) 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com Tochtergesellschaften - weltweit Subsidiary companies - worldwide Australia HARTING Pty Ltd Suite 11 / 2 Enterprise Drive Bundoora 3083, AUS-Victoria Tel. +61 9466 7088, Fax +61 9466 7099 E-Mail: [email protected], www.HARTING.com Belgium HARTING N.V./S.A. Z.3 Doornveld 23, B-1731 Zellik Tel. +32 2 466 0190, Fax +32 2 466 7855 E-Mail: [email protected], www.HARTING.be Brazil HARTING Ltda. Av. Dr. Lino de Moraes, Pq. Jabaquara, 255 CEP 04360-001 – São Paulo – SP – Brazil Tel. +55 11 5035 0073, Fax +55 11 5034 4743 E-Mail: [email protected] www.HARTING.com.br China Zhuhai HARTING Limited, Shanghai branch Room 5403, HK New World Tower 300 Huai Hai Road (M.) Shanghai 200021, China Tel. +86 21 6386 2200, Fax +86 21 6386 8636 E-Mail: [email protected] www.HARTING.com.cn Deutschland HARTING Deutschland GmbH & Co. KG Postfach 2451, D-32381 Minden Simeonscarré 1, D-32427 Minden Tel. +49 571 8896 0, Fax +49 571 8896 282 E-Mail: [email protected] www.HARTING.com Finnland HARTING Oy Teknobulevardi 3-5, PL 35, FI-01530 Vantaa Tel. +358 9 350 87 300, Fax +358 9 350 87 320 E-Mail: [email protected], www.HARTING.fi Frankreich HARTING France 181 avenue des Nations, Paris Nord 2 BP 66058 Tremblay en France F-95972 Roissy Charles de Gaulle Cédex Tel. +33 1 4938 3400, Fax +33 1 4863 2306 E-Mail: [email protected], www.HARTING.fr Great Britain HARTING Ltd., Caswell Road Brackmills Industrial Estate GB-Northampton, NN4 7PW Tel. +44 1604 827 500, Fax +44 1604 706 777 E-Mail: [email protected] www.HARTING.co.uk Hong Kong HARTING (HK) Limited, Regional Office Asia Pacific 3512 Metroplaza Tower 1, 223 Hing Fong Road Kwai Fong, N. T., Hong Kong Tel. +852 2423 7338, Fax +852 2480 4378 E-Mail: [email protected] www.HARTING.com.hk Seite 67 India HARTING India Private Limited No. D, 4th Floor, ‚Doshi Towers‘ No. 156 Poonamallee High Road, Kilpauk, Chennai 600 010, Tamil Nadu, Chennai Tel. +91 44 435604 15, Fax +91 44 435604 17 E-Mail: [email protected], www.HARTING.com Italy HARTING SpA Via dell‘Industria 7, I-20090 Vimodrone (Milano) Tel. +39 02 250801, Fax +39 02 2650 597 E-Mail: [email protected], www.HARTING.it Japan HARTING K. K. Yusen Shin-Yokohama 1 Chome Bldg., 2F 1-7-9, Shin-Yokohama, Kohoku-ku, Yokohama Yokohama 222-0033 Japan Tel. +81 45 476 3456, Fax +81 45 476 3466 E-Mail: [email protected], www.HARTING.co.jp Korea HARTING Korea Limited #308 Yatap Leaders Building 342-1, Yatap-dong, Bundang-gu, Sungnam-Si Gyeonggi-Do 463-828 Republic of Korea Tel. +82 31 781 4613, Fax +82 31 781 4616 E-Mail: [email protected] www.HARTING.com.cn/kr Netherlands HARTING B.V. Larenweg 44, NL-5234 KA ‚s-Hertogenbosch Postbus 3526, NL-5203 DM ‚s-Hertogenbosch Tel. +31 736 410 404, Fax +31 736 440 699 E-Mail: [email protected], www.HARTINGbv.nl Norway HARTING A/S Østensjøveien 36, N-0667 Oslo Tel. +47 22 700 555, Fax +47 22 700 570 E-Mail: [email protected], www.HARTING.no Österreich HARTING Ges. m. b. H. Deutschstraße 19, A-1230 Wien Tel. +431 6162121, Fax +431 6162121-21 E-Mail: [email protected], www.HARTING.at Poland HARTING Polska Sp. z o. o Ul. Kamienskiego 201-219, PL-51-126 Wroclaw Tel. +48 71 352 81 71, Fax +48 71 320 74 44 E-Mail: [email protected], www.HARTING.pl Portugal HARTING Iberia, S. A. Avda. Josep Tarradellas, 20-30, 4 o 6a E-08029 Barcelona Tel. +34 93 363 84 75, Fax +34 93 419 95 85 E-Mail: [email protected] www.HARTING.es/pt Ausgabe 11/2009 Russia HARTING ZAO Maily Sampsoniyevsky prospect 2A 194044 Saint Petersburg, Russia Tel. +7 812 327 6477, Fax +7 812 327 6478 E-Mail: [email protected], www.HARTING.ru Sweden HARTING AB Gustavslundsvägen 141 B 4tr, S-167 51 Bromma Tel. +46 8 445 7171, Fax +46 8 445 7170 E-Mail: [email protected], www.HARTING.se Schweiz HARTING AG Industriestrasse 26, CH-8604 Volketswil Tel. +41 44 908 20 60, Fax +41 44 908 20 69 E-Mail: [email protected], www.HARTING.ch Singapore HARTING Singapore Pte Ltd. 25 International Business Park #02-06 German Centre, Singapore 609916 Tel. +65 6225 5285, Fax +65 6225 9947 E-Mail: [email protected], www.HARTING.com Spain HARTING Iberia S.A. Josep Tarradellas 20-30 4o 6a E-08029 Barcelona Tel. +34 93 363 84 75, Fax +34 93 419 95 85 E-Mail: [email protected], www.HARTING.es Taiwan HARTING R.O.C. Limited Room 1, 5/F, 495 GuangFu South Road RC-110 Taipei, Taiwan Tel. +886 227 586 177, Fax +886 227 587 177 E-Mail: [email protected], www.HARTING. com.tw Czech Republic HARTING spol. s.r.o. Ml´ynská 2, CZ-160 00 Praha 6 Tel. +420 220 380 460, Fax +420 220 380 461 E-Mail: [email protected], www.HARTING.cz Ungarn HARTING Magyarország Kft. Fehérvári út 89-95, H-1119 Budapest Tel. +36 1 205 34 64, Fax +36 1 205 34 65 E-Mail: [email protected], www.HARTING.hu USA HARTING Inc. of North America 1370 Bowes Road, USA-Elgin, Illinois 60123 Tel. +1 877 741-1500 (toll free) Fax +1 866 278-0307 (Inside Sales) Fax +1 847 717-9430 (Sales and Marketing) E-Mail: [email protected], www.HARTING-USA.com Eastern-Europe HARTING Eastern Europe GmbH Bamberger Straße 7, D-01187 Dresden Tel. +49 351 4361 760, Fax +49 351 4361 770 E-Mail: [email protected] www.HARTING.com