Typ: KTBSB
Transcrição
Typ: KTBSB
Typ: KTBSB-112.070 Art.-No.: MA200202 Features: Klimaregler mechanisch mit neutraler Zone, AP, 5...30°C, für 4-Rohrsysteme, Wechsler, 230VAC, 6(3)A, Schalter Ventilator 3-stufig, Schalter "EIN/AUS", reinweiß ähnlich RAL 9010 Application: Control and monitoring of temperatures in closed, dry spaces. Remote control of air conditioners, climate chests, fan coil systems in living and office spaces and doctors’ practices. Individual room optimisation in central air conditioning systems (hotels, hospitals etc.). Suitable for all heating systems. (Please note the maximum switching current) Technical Data: Dimensions of housing: Dimensions of packaging: Number of outputs: Number, control range: Output signal: Output signal: External setting: Configuration: Rated impulse voltage: Operating voltage: Design: On Off: setting range to: 110 x 26 x 110,7 mm 115 x 45 x 115 mm 7 1 Heizen, schaltend (230 VAC, 50 Hz) Kühlen, schaltend (230 VAC, 50 Hz) yes Einzelraumklimaregler mit neutraler Zone für 4-Rohrsysteme, 3stufiger Lüfterausgang, 2x Hilfsausgang "Ein/Aus" 4000 V 230 VAC, 50 Hz Berlin 3000 yes 30 setting range from: Electrical connection: Fancoil: Colour of housing: Sensor: Weight: Output, heating: Hysteresis: Output, cooling: Storage temperature: Air distribution systems: Material of housing: max. switching voltage: max. switching current: mechanical range setting: min. switching voltage: Installation/fastening: Neutral zone: Surface quality: potential-free: Control range up to: Control range from: Control function: Switching element: ON/OFF switch: 3-stage fan switch: Switching contact: Switching power: Degree of protection: Protection class: Safety and EMC: Scale - degrees Celsius: Set point adjuster: Part Air Conditioning: Thermal feedback: Ambient temperature up to: Ambient temperature from: Degree of fouling: other/similar items: Accessories: 5 Schraubklemmen yes reinweiß, ähnlich RAL 9010 Bimetall ca. 170 g yes Heizen ca. 1 K, Kühlen ca. 2 K, bei einer Temperaturänderung von max. 4 K / h yes -20...+70 °C yes Kunststoff ABS 230 VAC, 50 Hz 6 (3) A yes 230 VAC, 50 Hz Aufputz- / Wandmontage oder mittels Adapterplatte auf UP-Dose ca. 2 K matt no 30 5 Heizen und Kühlen Bimetallkontakt yes yes Wechsler 1380 W IP 30 II, nach entsprechender Montage gemäß DIN EN 60730 yes yes yes yes 30 0 2 weitere Regler mit Ausgängen für Heizen / Kühlen finden Sie unter Heiztechnik (RTBSB/FTR) Klemmenleisten: VOORL passende Ventilstellantriebe: ZBOOA010.100 Adapterplatte zur Montage auf UP-Dose: JZ-17 Permissible atmospheric humidity: Ciruit Diagram: max. 95% r. H., nicht kondensierend