implant - Dentoflex
Transcrição
implant - Dentoflex
PRODUCTS CATALOG 2016 4 5 Presentation of the Company “The quality of a company is also measured by its years of experience in the market” Quality Policy and Certifications 6 8 Presentation of the Supreme Family Surface Treatment Presentation Morse Taper Internal Hexagon External Hexagon of New Families of Implants 29 42 57 Presentation of the Classic Family Presentation of the Arrow Family Presentation of the Short Family Internal Hexagon External Hexagon Morse Taper Internal Hexagon Morse Taper External Hexagon 63 Presentation of the Solid Family 66 69 70 Zigoflex Reference Guide Instrumentals 84 Flex Implant Temporary Implant 76 80 82 Articulated Bar Kits Hygiene Procedures * The images of this catalog are for illustrative purposes only BETApro® 86 References PRESENTATION Presentation of the Company 4 Dentoflex was founded in December 1977; being a family company, our workers, customers and suppliers are an extension of our family, and we are proud to have operated in the dental market for over 36 years with ethics and respect. The years in market have brought us credibility and trust, and our success was the result of commitment with the quality of our products and services. Aiming to improve the quality of life of patients, we are dedicated to the development and improvement of our processes. Using leading edge machinery and equipments for the production of our line of implants and prosthetic components, Dentoflex establishes a strict and reliable quality control. The qualification of its workers and the tools offered to these ensure the reproducibility and repeatability of all items produced. “Maintenance of the efficacy and continuous improvement of the internal processes and the Quality Management System” “The satisfaction of the needs and compliance with the requirements of our customers” Operate in the area of dental health, promoting continuous improvement in the processes and products, providing development to customers and workers. Concerned in providing the dental market high added-value quality materials, Dentoflex implemented a strict Quality Management System obtaining the certifications and GMP – Good Manufacturing Practices from the National Health Surveillance Agency – ANVISA. The GMP certification is known for its importance in allowing dental and medical companies to sell their products in the domestic and foreign market. Adopted by ANVISA through its General Management of Health Product Technology, the GMP (Good Manufacturing Practices) certificate ensures the quality of the processes and executes patient health risk control. DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM Quality Policy and Certifications 5 Surface treatment with aluminum oxide blasting followed by passivation combines ideal texture and porosity for an excellent biological effect, providing conditions for osseointegration and clinical success. The Dentoflex implants provide a surface roughness up to 300 times greater than a machined surface, increasing the boneimplant contact surface by up to six times, obtaining excellent primary stability. DENTOFLEX | IMPLANTS SYSTEM “Dentoflex implants provide a surface roughness up to 300 times greater than a machined surface” 6 Presentation of the new Families of Implants Dear Doctor You are receiving a new catalog of Dentoflex products. Through it we present our new products, packages and a more ergonomic organization of our implants and prosthetic components. The classification of our products through FAMILIES aims at facilitating the identification of the products by our consumers to enable quick search and greater ease during purchase. Our packaging is more practical, allowing a clearer view of the product and a much greater ease in removing the implant, which now has a tearing section for opening the primary packaging and surgical paper in its secondary packaging. Our classic implants (cylindrical internal hexagon and cylindrical external hexagon) no longer have the plastic transporter or metal mount because they are now all Internal Torque type, that is, the implant is captured from the packaging, transported and initially inserted on the created surgical alveolus through a contra-angle driver. This provides greater safety, less time and greater ease in your surgical procedure. Furthermore, our insertion drivers gained a vertical mark and identification for its use, once more facilitating its use and enabling visual of the position of the hexagon of the implant when its veneers are in the vestibular position, optimizing the choice of prosthetic component when this implant is inclined in any direction. Lastly, Dentoflex continues its efforts in the development and improvement processes of its products in order for the most important person to us to always have the best to work with: You! DENTOFLEX | IMPLANTS SYSTEM SURFACE TREATMENT Surface Treatment 7 SUPREME Family Implant MORSE TAPER Has internal taper of 11.5o Available with prosthetic index Internal thread of 1.8 mm Simplified placement (capture and insertion driver) with depth indication (1.0, 2.0 or 3.0 mm) Implant cover and mount not included. Available in diameters of 3.50, 3.75, 4.25 and 5.0 mm. Surface treatment on the entire implant body. Implant Diameter Implant Length 3,50 8,5 3,75 10,0 4,25 11,5 5,00 13,0 15,0 8 [ The Supreme family of implants is characterized by a very high primary stability in all types of bones, which in most cases enables the application of the immediate loading technique in multiple or single prostheses. These implants have a tapered body and three different thread shapes: at the apex of the implant, the “V” shaped threads provide a high cutting power of the bone; in the central part of the body, the trapezoidal threads help the primary stability of the implant, besides helping blood-clot retention, and lastly the square threads located close to the implant platform, which will increase the initial stability of the implant and absorb up to 10 times the stress caused by mandible excursion when compared to “V” shaped threads. The grooves between the threads further increase the contact between the surface of the implant and the bone tissue. In addition to this, the implants of the Supreme family have the Platform Switch, which requires the use of components of smaller diameter when compared to the size of the implant platform, which significantly reduces bone height loss around the implant. There is also surface treatment on the entire body of the implant and they are produced in commercially pure titanium grade IV The Supreme Family Implants are presented in three types of prosthetic connections: Morse Taper, Internal Hexagon and External Hexagon IMPLANT INSTALLATION DRIVER DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM MILLING SEQUENCE FOR SUPREME MORSE TAPER IMPLANT Available in Short and Long sizes 9 SUPREME Implant cover Are presented in four implant cover height sizes to be used according to the surgical technique used UNIVERSAL TRUNNION With and Without Prosthetic Index b 0,0 mm 1,0 mm 1,20 2,0 mm 1,20 10 N/cm 3,0 mm 1,20 10 N/cm STRAIGHT UNIVERSAL TRUNNION WITH INDEX b a c 1,20 10 N/cm STRAIGHT UNIVERSAL TRUNNION WITHOUT INDEX 32 N/cm 1,20 a 10 N/cm 20 N/cm c Healing Caps Diameter 1,20 Belt Height 3,3 0,8 – 1,5 – 2,5 – 3,5 – 4,5 – 5,5 – 6,5 4,5 0,8 – 1,5 – 2,5 – 3,5 – 4,5 – 5,5 – 6,5 USED FOR PRODUCING CEMENTED PROSTHESES, SINGLE OR MULTIPLE 1,20 DENTOFLEX | IMPLANTS SYSTEM 10 N/cm Implant transfer coping Straight Universal Trunnion Open Tray Transfer of the Implant with Short and Long Index Open Tray Transfer of the Implant without Short and Long Index 1,20 1,20 10 N/cm Diameter (a) Trunnion Height (b) Belt Height (c) 3,3 4,0 - 6,0 0,8 – 1,5 – 2,5 – 3,5 – 4,5 – 5,5 – 6,5 4,5 4,0 - 6,0 0,8 – 1,5 – 2,5 – 3,5 – 4,5 – 5,5 – 6,5 DENTOFLEX | IMPLANTS SYSTEM Produced in titanium Installation torque: 20N Available in two prosthesis seating diameters: 3,3 and 4,5 mm 10 N/cm Implant Analog 10 11 Without Prosthetic Index b Universal Trunnion Transfer 4,0 ANGLED UNIVERSAL TRUNNION WITHOUT INDEX Diameter Trunnion Height Color 3,3 4,0 Yellow 3,3 6,0 Blue 4,5 4,0 Yellow 4,5 6,0 Blue a 20 N/cm 6,0 UNIVERSAL TRUNNION ANALOG 1,20 c USED FOR PRODUCING CEMENTED PROSTHESES, SINGLE OR MULTIPLE DENTOFLEX | IMPLANTS SYSTEM Produced in titanium Available straight (single item) and angled (has pass through screw – 17º, 22º and 30º) Installation torque: 20N Diameter Trunnion Height 3,3 4,0 3,3 6,0 4,5 4,0 4,5 6,0 CEMENTED SINGLE PROSTHESIS Universal Trunnion Coping Temporary (Anti-Rotational) Calcinable (Anti-Rotational) Alumina (Anti-Rotational) Angled Universal Trunnion Diameter (a) Trunnion Height (b) Angulation Belt Height (c) Diameter Coping Height 3,3 4,0 - 6,0 17°- 22°- 30° 1,5 – 2,5 – 3,5 3,3 4,0 4,5 4,0 - 6,0 17°- 22°- 30° 1,5 – 2,5 – 3,5 3,3 6,0 4,5 4,0 4,5 6,0 CEMENTED MULTIPLE PROSTHESIS DENTOFLEX | IMPLANTS SYSTEM SUPREME UNIVERSAL TRUNNION STRAIGHT AND ANGLED UNIVERSAL TRUNNION COMPONENTS Universal Trunnion Coping Temporary (Round) 12 Calcinable (Round) 13 ESTHETICONE SUPREME MIRUSCONE 20 N/cm 20 N/cm 1,20 1,20 20 N/cm 20 N/cm ANGLED MIRUSCONE WITH INDEX 2,20 ANGLED ESTHETICONE WITH INDEX 2,20 USED FOR PRODUCING MULTIPLE SCREWED PROSTHESES USED FOR PRODUCING SINGLE OR MULTIPLE SCREWED PROSTHESES Produced in titanium Produced in titanium Available straight without index (single item) and angled Installation torque: 20N with or without index (has pass-through screw - 17°, 22° and Installation torque of prosthesis retaining screw: 10N 30°) Minimum occlusal distance: 6.5 mm Installation torque: 20N Available straight without index (single item) and angled with or wi- Installation torque of prosthesis retaining screw: 10N thout index (17°, 22° and 30°) (has pass-through screw) Minimum occlusal distance: 4.5 mm Straight Estheticone Straight Miruscone BELT HEIGHTS AVAILABLE BELT HEIGHTS AVAILABLE Belt height of the Angled Miruscone BELT HEIGHT ON ANGLED ESTHETICONE 1,5 - 2,5 - 3,5 1,5 - 2,5 - 3,5 DENTOFLEX | IMPLANTS SYSTEM Open Tray Transfer 1,20 1,20 1,20 1,20 Lab Screw (optional) Analog Closed Tray Transfer Available AR and Round 1,20 1,20 1,20 1,20 Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) Healing Cap Lab Screw (optional) 14 STRAIGHT AND ANGLED ESTHETICONE COMPONENTS Open Tray Transfer Available AR and Round Closed Tray Transfer Round Plastic Sleeve Angled Estheticone BELT HEIGHTS STRAIGHT AND ANGLED MIRUSCONE COMPONENTS Round Metal Base Sleeve 0,8 - 1,5 - 2,5 - 3,5 - 4,5 - 5,5 STRAIGHT ESTHETICONE WITHOUT INDEX Round Titanium Sleeve 1,20 Lab Screw (optional) Round Metal Base Sleeve 1,20 Lab Screw (optional) Round Plastic Sleeve 1,20 Lab Screw (optional) Round Titanium Sleeve 1,20 DENTOFLEX | IMPLANTS SYSTEM 0,8 - 1,5 - 2,5 - 3,5 - 4,5 - 5,5 - 6,5 STRAIGHT MIRUSCONE WITHOUT INDEX Lab Screw (optional) Analog 15 Implant SUPREME O’RING INDICATED FOR OVERDENTURE RETAINING 20 N/cm 2,50 Produced in titanium INTERNAL HEXAGON INDICATED FOR SINGLE AND MULTIPLE PROSTHESES Installation torque: 20N Indicated for all types of bone quality Requires Dentoflex installation driver Tapered body BELT HEIGHTS AVAILABLE 0,8 - 1,5 - 2,5 - 3,5 - 4,5 - 5,5 - 6,5 High initial stability Surface treatment on the entire implant body Implant cover included Internal Hexagon 2.50 mm CASTABLE O’RING Implant Diameter Implant Length 3,50 8,5 3,75 10,0 4,25 11,5 5,00 13,0 15,0 Used in natural root or in distal position of the bar-clip. Metallic O’ring Capsule O’ring Spacer Washer Plastic Capsule for Transfer BARRA CLIP IMPLANT INSTALLATION DRIVER INDICATED FOR OVERDENTURE RETAINING Ideal distance between implants: 22 mm 3 clips (straight, 35° and 70°) and 2 bars included Reto 35° 70° SELECTION OF PLATFORM SWITCH COMPONENTS IMPLANT COMPONENT 3,50 3,25 3,75 3,25 4,25 3,75 5,00 4,25 DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM MILLING SEQUENCE FOR SUPREME IH IMPLANT Available in Short and Long sizes 16 17 SUPREME HEALING CAPS Available at heights of 3.0, 5.0 and 7.0 mm Healing cap without emergence profile 1,20 Available at heights of 3.0, 5.0 and 7.0 mm Healing cap with emergence profile 1,20 HEIGHTS EMERGENCE PROFILE 3,0 - 5,0 - 7,0 5,0 - 6,0 PERMANENT PROSTHESIS COMPONENTS UCLA Possibility of producing cemented or screwed prosthesis Available with plastic body and ring or plastic body and ring in Cr-Co Lab screw included Installation Torque: 32N 32 N/cm 32 N/cm 1,30 1,30 Plastic Ucla Available AR and Round 1,20 Ucla Metal Belt Available AR and Round 1,20 Open tray transfer Available short, medium and long Closed tray transfer STRAIGHT TRUNNION FOR CEMENTED PROSTHESIS 32 N/cm 1,30 Indicated for multiple cemented prosthesis IH Implant Analog BELT HEIGHTS TEMPORARY PROSTHESIS COMPONENTS SCREWED PROSTHESIS 32 N/cm 1,30 32 N/cm 1,30 Munhão Temporário para Prótese Parafusada Disponível AR e Circular 18 ANGLED TRUNNION FOR CEMENTED PROSTHESIS BELT HEIGHTS ANGULATIONS AVAILABLE 1,0 - 2,0 - 3,0 15o - 25o - 35o DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM 1,0 - 2,0 - 3,0 - 4,0 - 5,0 19 ESTHETICONE USED FOR PRODUCING MULTIPLE SCREWED PROSTHESES 32 N/cm Produced in titanium 2,20 USED FOR PRODUCING SINGLE OR MULTIPLE SCREWED 32 N/cm PROSTHESES 2,20 Installation torque: straight 32 N, angled 20N Produced in titanium Installation torque of prosthesis retaining screw: 10N Installation torque: 32N Minimum occlusal distance: 4.5mm Installation torque of prosthesis retaining screw: 10N Available straight or angled (17°, 22° and 30°) Minimum occlusal distance: 6.7 mm Prosthesis retaining screw included Available straight or angled (17°, 22° and 30°) BELT HEIGHTS BELT HEIGHTS 1,0 - 2,0 - 3,0 - 4,0 - 5,0 1,0 - 2,0 - 3,0 1,30 1,20 BELT HEIGHTS DENTOFLEX | IMPLANTS SYSTEM Open Tray Transfer STRAIGHT AND ANGLED ESTHETICONE COMPONENTS 1,20 Lab Screw (optional) Round Plastic Sleeve 1,20 Lab Screw (optional) Analog Closed Tray Transfer Available AR and Round 1,20 1,20 Healing Cap Round Metal Base Sleeve 17o - 22o - 30o Open Tray Transfer Available AR and Round Closed Tray Transfer 1,20 ANGULATIONS AVAILABLE 1,0 - 2,0 - 3,0 17o - 22o - 30o STRAIGHT AND ANGLED MIRUSCONE COMPONENTS 20 BELT HEIGHTS ANGULATIONS AVAILABLE 1,0 - 2,0 - 3,0 1,20 ANGLED ESTHETICONE 20 N/cm ANGLED MIRUSCONE 20 N/cm 1,20 1,20 Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) Round Titanium Sleeve 1,20 Lab Screw (optional) Metal Base Sleeve Available AR and Round 1,20 Lab Screw (optional) Plastic Sleeve Available AR and Round 1,20 Lab Screw (optional) Titanium Sleeve Available AR and Round 1,20 DENTOFLEX | IMPLANTS SYSTEM SUPREME MIRUSCONE Lab Screw (optional) Analog 21 Implant SUPREME OVERDENTURE RETAINING SYSTEM O’RING INDICATED FOR OVERDENTURE RETAINING 32 N/cm 2,50 Produced in titanium EXTERNAL HEXAGON Installation torque: 32N Requires Dentoflex installation driver INDICATED FOR SINGLE AND MULTIPLE PROSTHESES Includes plastic capsule for transfer, titanium capsule and Indicated for all types of bone quality spacer ring Tapered body High initial stability BELT HEIGHTS AVAILABLE Implant cover included 1,0 - 2,0 - 3,0 - 4,0 - 5,0 Diameters Hexagon Hexagon Height 8,5 3,75 4,25 Lengths 10,0 2,70 0,70 11,5 13,0 5,00 15,0 CASTABLE O’RING Metallic O’ring Capsule O’ring Spacer Washer MILLING SEQUENCE FOR SUPREME EH IMPLANT Plastic Capsule for Transfer BAR CLIP INDICATED FOR OVERDENTURE RETAINING IMPLANT INSTALLATION DRIVER Ideal distance between implants: 22mm 3 clips (straight, 35° and 70°) and 2 bars included Reto 35° SELECTION OF PLATFORM SWITCH COMPONENTS IMPLANT COMPONENT 3,75 3,25 mini (3,6) 4,25 3,25 mini (3,6) 5,00 3,75 (4,1) DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM Used in natural root or in distal position of the bar-clip. 70° Available in Short and Long sizes 22 23 SUPREME HEALING CAPS PERMANENT PROSTHESIS COMPONENTS 1,20 UCLA 1,20 Possibility of producing cemented or screwed prosthesis Available with plastic body and ring or plastic body and ring in Cr-Co Lab screw included Installation Torque: 32N Healing cap with emergence profile - SPE Healing cap without emergence profile 32 N/cm HEIGHTS EMERGENCE PROFILE 2,0 - 3,0 - 4,0 - 5,0 - 6,0 5,0 - 6,0 1,20 32 N/cm 1,30 1,30 Plastic Belt Available AR and Round Metal Belt Available AR and Round 1,20 STRAIGHT TRUNNION FOR CEMENTED PROSTHESIS Closed tray transfer Open tray transfer Available short, medium and long 32 N/cm 1,30 EH Implant Analog Indicated for multiple cemented prosthesis BELT HEIGHTS 24 TEMPORARY PROSTHESIS COMPONENTS SCREWED PROSTHESIS ANGLED TRUNNION FOR CEMENTED PROSTHESIS 32 N/cm 1,30 32 N/cm 1,30 Temporary Trunnion for Screwed Prosthesis Available AR and Round BELT HEIGHTS ANGULATIONS AVAILABLE 1,0 - 2,0 - 3,0 15o - 25o - 35o DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM 1,0 - 2,0 - 3,0 - 4,0 - 5,0 25 SUPREME MIRUSCONE ESTHETICONE 32 N/cm USED FOR PRODUCING MULTIPLE SCREWED PROSTHESES PROSTHESES Produced in titanium Installation torque: straight 32 N, angled 20N Installation torque of prosthesis retaining screw: 10N Minimum occlusal distance: 4.5 mm Available straight or angled (17°, 22° and 30°) 32 N/cm 2,20 USED FOR PRODUCING SINGLE OR MULTIPLE SCREWED 2,20 Produced in titanium Installation torque: straight 32N, angled 20N Installation torque of prosthesis retaining screw: 10N Minimum occlusal distance: 6.7 mm Available straight and angled (17° 22° and 30°) BELT HEIGHTS BELT HEIGHTS 1,0 - 2,0 - 3,0 ANGLED MIRUSCONE 1,20 BELT HEIGHTS ANGULATIONS 1,0 - 2,0 - 3,0 17o - 22o - 30o 20 N/cm BELT HEIGHTS DENTOFLEX | IMPLANTS SYSTEM 1,20 1,20 Lab Screw (optional) Round Plastic Sleeve Closed Tray Transfer Available AR and Round 1,20 1,20 1,20 1,20 Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) 1,20 Lab Screw (optional) Analog 26 STRAIGHT AND ANGLED ESTHETICONE COMPONENTS Healing Cap Round Metal Base Sleeve 17o - 22o - 30o Open Tray Transfer Available AR and Round Closed Tray Transfer 1,20 ANGULATIONS AVAILABLE 1,0 - 2,0 - 3,0 STRAIGHT AND ANGLED MIRUSCONE COMPONENTS Open Tray Transfer ANGLED ESTHETICONE Round Titanium Sleeve 1,20 Lab Screw (optional) Metal Base Sleeve Available AR and Round 1,20 Lab Screw (optional) Plastic Sleeve Available AR and Round 1,20 Lab Screw (optional) Titanium Sleeve Available AR and Round 1,20 DENTOFLEX | IMPLANTS SYSTEM 20 N/cm 1,0 - 2,0 - 3,0 - 4,0 - 5,0 Lab Screw (optional) Analog 27 Family OVERDENTURE RETAINING SYSTEM SUPREME O’RING INDICATED FOR OVERDENTURE RETAINING 2,50 Produced in titanium Installation torque: 32N Includes plastic capsule for transfer, titanium capsule and spacer ring *Starting Ø 3,75 BELT HEIGHTS AVAILABLE 1,0 - 2,0 - 3,0 - 4,0 - 5,0 CASTABLE O’RING Metallic O’ring Capsule O’ring Spacer Washer Plastic Capsule for Transfer BAR CLIP INDICATED FOR OVERDENTURE RETAINING Ideal distance between implants: 22 mm 3 clips (straight, 35° and 70°) and 2 bars included Reto 28 35° 70° [ The Classic family implants represent the entire tradition and safety of Dentoflex implants. Having a cylindrical body, micro threads on the prosthetic platform, four cutting grooves on its apex, but with significant improvements, such as surface treatment on the entire body of the implant and platform switch, produced in commercially pure titanium grade IV. Another significant improvement was the elimination of mounts, now replaced by counter angle switches on both the internal hexagon and external hexagon to capture, transport and execute the initial installation of the implant, highly facilitating the day-to-day of the dental surgeon. The implants of the Classic family are supplied with implant cover and already have the new more practical and safer packaging. DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM Used in natural root or in distal position of the bar-clip. 29 CLASSIC Implant INTERNAL HEXAGON INDICATED FOR SINGLE AND MULTIPLE PROSTHESES HEALING CAPS Available at heights of 3.0, 5.0 and 7.0 mm Healing cap without emergence profile 1,20 Available at heights of 3.0, 5.0 and 7.0 mm Healing cap with emergence profile 1,20 Indicated for all types of bone quality Cylindrical body High cutting power Double Thread HEIGHTS EMERGENCE PROFILE 3,0 - 5,0 - 7,0 5,0 - 6,0 Surface treatment on the entire implant body Internal Hexagon 2.50mm IMPLANT DIAMETER IMPLANT LENGTH 3,50 7,00 (*) 1,20 3,75 8,00 1,20 4,00 10,0 4,25 11,5 Open tray transfer Available short, medium and long 5,00 13,0 Closed tray transfer 15,0 (*) As from diameter of 3.75 IH Implant Analog MILLING SEQUENCE FOR CLASSIC IH IMPLANT SCREWED PROSTHESIS 32 N/cm IMPLANT INSTALLATION DRIVER SELECTION OF PLATFORM SWITCH COMPONENTS IMPLANT COMPONENT 3,50 3,25 3,75 3,25 4,00 3,25 4,25 3,75 5,00 4,25 1,30 DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM COMPONENTS TEMPORARY PROSTHESIS Temporary Trunnion for Screwed Prosthesis Available AR and Round Available in Short and Long sizes 30 31 MIRUSCONE CLASSIC PERMANENT PROSTHESIS COMPONENTS UCLA Possibility of producing cemented or screwed prosthesis Available with plastic body and ring or plastic body and ring in Cr-Co Lab screw included Installation Torque: 32N USED FOR PRODUCING MULTIPLE SCREWED PROSTHESEIS 32 N/cm Produced in titanium 2,20 Installation torque: straight 32 N, angled 20N Installation torque of prosthesis retaining screw: 10N 32 N/cm Minimum occlusal distance: 4.5 mm 32 N/cm 1,30 Available straight or angled (17°, 22° and 30°) 1,30 Plastic Ucla Available AR and Round Ucla Metal Belt Available AR and Round BELT HEIGHTS 1,0 - 2,0 - 3,0 STRAIGHT TRUNNION FOR CEMENTED PROSTHESIS 32 N/cm 1,30 ANGLED MIRUSCONE 20 N/cm Indicated for multiple cemented prosthesis 1,20 BELT HEIGHTS ANGULATION AVAILABLE 1,0 - 2,0 - 3,0 17o - 22o - 30o BELT HEIGHTS 1,0 - 2,0 - 3,0 - 4,0 - 5,0 ANGLED TRUNNION FOR CEMENTED PROSTHESIS Open Tray Transfer 32 N/cm Closed Tray Transfer 1,20 1,20 1,20 1,30 Healing Cap BELT HEIGHTS 1,0 - 2,0 - 3,0 ANGULATIONS AVAILABLE 15o - 25o - 35o Round Metal Base Sleeve 1,20 Lab Screw (optional) Round Plastic Sleeve 1,20 Lab Screw (optional) Round Titanium Sleeve 1,20 DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM STRAIGHT AND ANGLED MIRUSCONE COMPONENTS Lab Screw (optional) Analog 32 33 CLASSIC ESTHETICONE OVERDENTURE RETAINING SYSTEM USED FOR PRODUCING SINGLE OR MULTIPLE SCREWED PROS- 32 N/cm O’RING THESES 2,20 INDICATED FOR OVERDENTURE RETAINING Produced in titanium 32 N/cm Installation torque: 32N 2,50 Installation torque of prosthesis retaining screw: 10N 20 N/cm Installation torque: 32N Requires Dentoflex installation driver Minimum occlusal distance: 6.7 mm Includes plastic capsule for transfer, titanium capsule and Available straight or angled (17°, 22° and 30°) spacer ring BELT HEIGHTS BELT HEIGHTS AVAILABLE 1,0 - 2,0 - 3,0 - 4,0 - 5,0 1,0 - 2,0 - 3,0 - 4,0 - 5,0 CASTABLE O’RING ANGLED ESTHETICONE 1,30 Produced in titanium Used in natural root or in distal position of the bar-clip. BELT HEIGHTS ANGULATIONS AVAILABLE 1,0 - 2,0 - 3,0 17o - 22o - 30o Closed Tray Transfer Available AR and Round Open Tray Transfer Available AR and Round 1,20 1,20 Metallic O’ring Capsule 1,20 O’ring Spacer Washer Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) Plastic Capsule for Transfer BAR CLIP Metal Base Sleeve Available AR and Round 1,20 Plastic Sleeve Available AR and Round 1,20 Titanium Sleeve Available AR and Round INDICATED FOR OVERDENTURE RETAINING 1,20 Ideal distance between implants: 22 mm Lab Screw (optional) Lab Screw (optional) DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM STRAIGHT AND ANGLED ESTHETICONE COMPONENTS 3 clips (straight, 35° and 70°) and 2 bars included Lab Screw (optional) Straight 35° 70° Analog 34 35 CLASSIC Implant EXTERNAL HEXAGON INDICATED FOR SINGLE AND MULTIPLE PROSTHESES HEALING CAPS 1,20 1,20 Healing cap without Emergence profile Healing cap with emergence profile - SPE Indicated for all types of bone quality Cylindrical body High cutting power. HEIGHTS EMERGENCE PROFILE 2,0 - 3,0 - 4,0 - 5,0 - 6,0 5,0 - 6,0 Double Thread Implant cover included DIAMETER LENGTH 3,25 7,0 3,75 8,5 4,00 10,0 5,00 11,5 1,20 1,20 Closed tray transfer Open tray transfer Available short, medium and long 13,0 15,0 MILLING SEQUENCE FOR CLASSIC EH IMPLANT EH implant analog SCREWED PROSTHESIS 32 N/cm 1,30 IMPLANT INSTALLATION DRIVER SELECTION OF PLATFORM SWITCH COMPONENTS IMPLANT COMPONENT 3,25 3,25 mini (3,6) 3,75 3,25 mini (3,6) 4,00 3,25 mini (3,6) 5,00 3,75 (4,1) Temporary Trunnion for Screwed Prosthesis Available AR and Round DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM TEMPORARY PROSTHESIS COMPONENTS Available in Short and Long sizes 36 37 CLASSIC PERMANENT PROSTHESIS COMPONENTS UCLA MIRUSCONE Possibility of producing cemented or screwed prosthesis Available with plastic body and ring or plastic body and ring in Cr-Co Lab screw included Installation Torque: 32N USED FOR PRODUCING MULTIPLE SCREWED PROSTHESES Produced in titanium 32 N/cm Installation torque: straight 32 N, angled 20N Installation torque of prosthesis retaining screw: 10N 2,20 32 N/cm 32 N/cm Minimum occlusal distance: 4.5 mm Available straight or angled (17°, 22° and 30°) 1,30 1,30 Plastic Belt Available AR and Round Metal Belt Available AR and Round BELT HEIGHTS 1,0 - 2,0 - 3,0 STRAIGHT TRUNNION FOR CEMENTED PROSTHESIS 20 N/cm 32 N/cm ANGLED MIRUSCONE 1,20 1,30 BELT HEIGHTS ANGULATION 1,0 - 2,0 - 3,0 17o - 22o - 30o Indicated for multiple cemented prosthesis DENTOFLEX | IMPLANTS SYSTEM 1,0 - 2,0 - 3,0 - 4,0 - 5,0 ANGLED TRUNNION FOR CEMENTED PROSTHESIS STRAIGHT AND ANGLED MIRUSCONE COMPONENTS Open Tray Transfer Closed Tray Transfer 1,20 1,20 1,20 Healing Cap 32 N/cm 1,30 Round Metal Base Sleeve BELT HEIGHTS 1,0 - 2,0 - 3,0 ANGULATIONS AVAILABLE 15o - 25o - 35o 1,20 Lab Screw (optional) Round Plastic Sleeve 1,20 Lab Screw (optional) Round Titanium Sleeve 1,20 DENTOFLEX | IMPLANTS SYSTEM BELT HEIGHTS Lab Screw (optional) Analog 38 39 CLASSIC ESTHETICONE 32 N/cm OVERDENTURE RETAINING SYSTEM USED FOR PRODUCING SINGLE OR MULTIPLE SCREWED O’RING PROSTHESES 2,20 Produced in titanium INDICATED FOR OVERDENTURE RETAINING 2,50 Installation torque: straight 32 N, angled 20N Produced in titanium Installation torque of prosthesis retaining screw: 10N Installation torque: 32N Minimum occlusal distance: 6.7 mm Includes plastic capsule for transfer, titanium capsule and Available straight or angled (17°, 22° and 30°) spacer ring BELT HEIGHTS AVAILABLE BELT HEIGHTS 1,0 - 2,0 - 3,0 - 4,0 - 5,0 1,0 - 2,0 - 3,0 - 4,0 - 5,0 20 N/cm CASTABLE O’RING ANGLED ESTHETICONE BELT HEIGHTS ANGULATIONS AVAILABLE 1,0 - 2,0 - 3,0 17o - 22o - 30o Used in natural root or in distal position of the bar-clip. Open Tray Transfer Available AR and Round Closed Tray Transfer Available AR and Round 1,20 1,20 1,20 Metallic O’ring Capsule O’ring Spacer Washer Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) Metal Base Sleeve Available AR and Round 1,20 Plastic Sleeve Available AR and Round 1,20 Titanium Sleeve Available AR and Round Plastic Capsule for Transfer BAR CLIP 1,20 INDICATED FOR OVERDENTURE RETAINING Lab Screw (optional) Lab Screw (optional) DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM STRAIGHT AND ANGLED ESTHETICONE COMPONENTS Ideal distance between implants: 22 mm Lab Screw (optional) 3 clips (straight, 35° and 70°) and 2 bars included Straight 35° 70° Analog 40 41 41 Family Implant ARROW MORSE TAPER Has internal taper of 11.5o Available with prosthetic index Internal thread of 1.8 mm Simplified placement (capture and insertion driver) with depth indication (1.0, 2.0 or 3.0 mm) Implant cover and mount not included. Available in diameters of 3.50, 3.75 and 4.00 mm. Surface treatment on the entire implant body. Implant Diameter Implant Length 3,50 8,0 3,75 10,0 4,00 11,5 13,0 15,0 [ The ARROW family implants have a cylindrical body, metric threads on the body and micro threads close to the prosthetic platform, whose function is to aid the primary stability of the implant, especially when there is a bone quality with narrow range of cortical and porous bone, besides having a sharp and cutting apex, which facilitates its insertion. The ARROW family implants are indicated for low density bones, types III and IV, and they cause an expansion of the medullary portion of the receptor bone when inserted, besides having the action of the micro threads on the bone corticomedullary transition region. The work with mills is reduced (in most cases only the spear milling cutter is used), which reduces the transoperative time. The prosthetic platforms available are the Morse Taper and Internal Hexagon types. IMPLANT INSTALLATION DRIVER DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM MILLING SEQUENCE FOR ARROW MORSE TAPER IMPLANT Available in Short and Long sizes 42 43 Implant cover ARROW Are presented in four implant cover height sizes to be used according to the surgical technique used UNIVERSAL TRUNNION With Prosthetic Index b 0,0 mm 1,0 mm 1,20 2,0 mm 1,20 10 N/cm 3,0 mm 1,20 10 N/cm STRAIGHT UNIVERSAL TRUNNION WITH INDEX b STRAIGHT UNIVERSAL TRUNNION WITHOUT INDEX a c 32 N/cm 1,20 1,20 10 N/cm a 10 N/cm 20 N/cm c Healing Caps Diameter Belt Height 3,3 0,8 – 1,5 – 2,5 – 3,5 – 4,5 – 5,5 – 6,5 4,5 0,8 – 1,5 – 2,5 – 3,5 – 4,5 – 5,5 – 6,5 1,20 USED FOR PRODUCING CEMENTED PROSTHESES, Produced in titanium Installation torque: 20N Available straight or angled (17o, 22o and 30o) Available in two prosthesis seating diameters: 3,3 and 4,5mm Has pass-through screw 1,20 DENTOFLEX | IMPLANTS SYSTEM 10 N/cm Implant transfer coping Straight Universal Trunnion Open Tray Transfer of the Implant with Available Short and Long Index Open Tray Transfer of the Implant without Available Short and Long Index 1,20 1,20 10 N/cm Diameter (a) Trunnion Height (b) Belt Height (c) 3,3 4,0 - 6,0 0,8 – 1,5 – 2,5 – 3,5 – 4,5 – 5,5 – 6,5 4,5 4,0 - 6,0 0,8 – 1,5 – 2,5 – 3,5 – 4,5 – 5,5 – 6,5 DENTOFLEX | IMPLANTS SYSTEM SINGLE OR MULTIPLE 10 N/cm Implant Analog 44 45 ARROW UNIVERSAL TRUNNION Without Prosthetic Index STRAIGHT AND ANGLED UNIVERSAL TRUNNION COMPONENTS Universal Trunnion Transfer ANGLED UNIVERSAL TRUNNION WITHOUT INDEX 4,0 6,0 b Diameter Trunnion Height Color 3,3 4,0 Yellow 3,3 6,0 Blue 4,5 4,0 Yellow 4,5 6,0 Blue a 20 N/cm UNIVERSAL TRUNNION ANALOG c USED FOR PRODUCING CEMENTED PROSTHESES, SINGLE OR DENTOFLEX | IMPLANTS SYSTEM MULTIPLES Diameter Trunnion Height 3,3 4,0 3,3 6,0 4,5 4,0 4,5 6,0 CEMENTED SINGLE PROSTHESIS Universal Trunnion Coping Produced in titanium Available straight (single item) and angled (has pass through screw – 17º, 22º and 30º) Installation torque: straight 32 N, angled 20N Temporary (Anti-Rotational) Calcinable (Anti-Rotational) Alumina (Anti-Rotational) Angled Universal Trunnion Diameter (a) Trunnion Height (b) Angulation Belt Height (c) Diameter Coping Height 3,3 4,0 - 6,0 17°- 22°- 30° 1,5 – 2,5 – 3,5 3,3 4,0 4,5 4,0 - 6,0 17°- 22°- 30° 1,5 – 2,5 – 3,5 3,3 6,0 4,5 4,0 4,5 6,0 CEMENTED MULTIPLE PROSTHESIS DENTOFLEX | IMPLANTS SYSTEM 1,20 Universal Trunnion Coping Temporary (Round) 46 Calcinable (Round) 47 MIRUSCONE ARROW ESTETICONE 20 N/cm 20 N/cm 1,20 1,20 20 N/cm ANGLED MIRUSCONE WITH INDEX 2,20 ANGLED ESTHETICONE WITH INDEX 2,20 USED FOR PRODUCING MULTIPLE SCREWED PROSTHESES USED FOR PRODUCING SINGLE OR MULTIPLE SCREWED PROSTHESES Produced in titanium Produced in titanium Available straight without index (single item) and angled with or Installation torque: 20N without index (has pass-through screw - 17°, 22° and 30°) Installation torque of prosthesis retaining screw: 10N Installation torque: 20N Minimum occlusal distance: 6.5 mm Installation torque of prosthesis retaining screw: 10N Available straight without index (single item) and angled with or wi- Minimum occlusal distance: 4.5 mm thout index (17°, 22° and 30°) (has pass-through screw) Prosthesis retaining screw included Prosthesis retaining screw included Straight Miruscone Straight Estheticone BELT HEIGHTS AVAILABLE 0,8 - 1,5 - 2,5 - 3,5 - 4,5 - 5,5 - 6,5 DENTOFLEX | IMPLANTS SYSTEM STRAIGHT MIRUSCONE WITHOUT INDEX Belt height of the Angled Miruscone BELT HEIGHT ON ANGLED ESTHETICONE 1,5 - 2,5 - 3,5 1,5 - 2,5 - 3,5 Closed Tray Transfer 1,20 1,20 STRAIGHT AND ANGLED ESTHETICONE COMPONENTS 1,20 Lab Screw (optional) Analog Closed Tray Transfer Available AR and Round Open Tray Transfer Available AR and Round 1,20 1,20 1,20 1,20 Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) Healing Cap 1,20 Angled Estheticone BELT HEIGHTS Open Tray Transfer Round Plastic Sleeve 0,8 - 1,5 - 2,5 - 3,5 - 4,5 - 5,5 STRAIGHT ESTHETICONE WITHOUT INDEX STRAIGHT AND ANGLED MIRUSCONE COMPONENTS Lab Screw (optional) 48 BELT HEIGHTS AVAILABLE Round Titanium Sleeve 1,20 Lab Screw (optional) Metal Base Sleeve Available AR and Round 1,20 Lab Screw (optional) Plastic Sleeve Available AR and Round 1,20 Lab Screw (optional) Titanium Sleeve Available AR and Round 1,20 DENTOFLEX | IMPLANTS SYSTEM 20 N/cm Lab Screw (optional) Analog 49 Implant ARROW O’RING INDICATED FOR OVERDENTURE RETAINING 20 N/cm 2,50 INTERNAL HEXAGON Produced in titanium Installation torque: 20N INDICATED FOR SINGLE AND MULTIPLE PROSTHESES Requires Dentoflex installation driver Indicated for all types of bone quality BELT HEIGHTS AVAILABLE 0,8 - 1,5 - 2,5 - 3,5 - 4,5 - 5,5 - 6,5 Cylindrical body High cutting power Double Thread Surface treatment on the entire implant body Implant Diameter Implant Length 3,50 8,0 3,75 10,0 4,00 11,5 CASTABLE O’RING 13,0 15,0 Used in natural root or in distal position of the bar-clip. Metallic O’ring Capsule O’ring Spacer washer Plastic Capsule for Transfer BAR CLIP IMPLANT INSTALLATION DRIVER INDICATED FOR OVERDENTURE RETAINING Ideal distance between implants: 22 mm 3 clips (straight, 35° and 70°) and 2 bars included Straight 35° SELECTION OF PLATFORM SWITCH COMPONENTS IMPLANT COMPONENT 3,50 3,25 3,75 3,25 4,00 3,25 DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM MILLING SEQUENCE FOR ARROW IH IMPLANT 70° Available in Short and Long sizes 50 51 PERMANENT PROSTHESIS COMPONENTS ARROW HEALING CAPS Available at heights of 3.0, 5.0 and 7.0 mm Healing cap without emergence profile 1,20 Available at heights of 3.0, 5.0 and 7.0 mm Healing cap with emergence profile 1,20 HEIGHTS EMERGENCE PROFILE 3,0 - 5,0 - 7,0 5,0 - 6,0 UCLA Possibility of producing cemented or screwed prosthesis Available with plastic body and ring or plastic body and ring in Cr-Co Lab screw included Installation Torque: 32N 32 N/cm 32 N/cm 1,30 1,30 Plastic Ucla Available AR and Round 1,20 Ucla Metal Belt Available AR and Round 1,20 Open tray transfer Available short, medium and long Closed tray transfer STRAIGHT TRUNNION FOR CEMENTED PROSTHESIS 32 N/cm 1,30 Indicated for multiple cemented prosthesis IH Implant Analog TEMPORARY PROSTHESIS COMPONENTS ANGLED TRUNNION FOR CEMENTED PROSTHESIS CEMENTED PROSTHESIS 32 N/cm 32 N/cm 1,30 1,30 Temporary Trunnion for Cemented Prosthesis Available AR and Round 52 1,0 - 2,0 - 3,0 - 4,0 - 5,0 BELT HEIGHTS 1,0 - 2,0 - 3,0 DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM BELT HEIGHTS ANGULATIONS AVAILABLE 15o - 25o - 35o 53 ARROW MIRUSCONE ESTHETICONE USED FOR PRODUCING MULTIPLE SCREWED PROSTHESES 32 N/cm Produced in titanium 2,20 USED FOR PRODUCING SINGLE OR MULTIPLE SCREWED 32 N/cm PROSTHESES 2,20 Installation torque: straight 32 N, angled 20N Produced in titanium Installation torque of prosthesis retaining screw: 10N Installation torque: 32N Minimum occlusal distance: 4.5 mm Installation torque of prosthesis retaining screw: 10N Available straight or angled (17°, 22° and 30°) Minimum occlusal distance: 6.7 mm Available straight or angled (17°, 22° and 30°) BELT HEIGHTS BELT HEIGHTS 1,0 - 2,0 - 3,0 - 4,0 - 5,0 1,0 - 2,0 - 3,0 20 N/cm ANGLED MIRUSCONE 20 N/cm ANGLED ESTHETICONE 1,30 1,20 ANGULATIONS AVAILABLE 1,0 - 2,0 - 3,0 17 - 22 - 30 o o DENTOFLEX | IMPLANTS SYSTEM STRAIGHT AND ANGLED MIRUSCONE COMPONENTS Open Transfer Tray 1,20 1,20 Lab Screw (optional) Round Plastic Sleeve 1,20 Lab Screw (optional) Analog 54 1,0 - 2,0 - 3,0 17o - 22o - 30o STRAIGHT AND ANGLED ESTHETICONE COMPONENTS Closed Tray Transfer Available AR and Round 1,20 1,20 1,20 1,20 Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) Healing Cap Round Metal Base Sleeve ANGULATIONS AVAILABLE Open Tray Transfer Available AR and Round Closed Tray Transfer 1,20 BELT HEIGHTS o Round Titanium Sleeve 1,20 Lab Screw (optional) Metal Base Sleeve Available AR and Round 1,20 Lab Screw (optional) Plastic Sleeve Available AR and Round 1,20 Lab Screw (optional) Titanium Sleeve Available AR and Round 1,20 DENTOFLEX | IMPLANTS SYSTEM BELT HEIGHTS Lab Screw (optional) Analog 55 Family ARROW OVERDENTURE RETAINING SYSTEM O’RING INDICATED FOR OVERDENTURE RETAINING 32 N/cm 2,50 Produced in titanium Installation torque: 32N Requires Dentoflex installation driver Includes plastic capsule for transfer, titanium capsule and spacer ring BELT HEIGHTS AVAILABLE 1,0 - 2,0 - 3,0 - 4,0 - 5,0 CASTABLE O’RING Metallic O’ring Capsule O’ring Spacer washer Plastic Capsule for Transfer BAR CLIP INDICATED FOR OVERDENTURE RETAINING Ideal distance between implants: 22 mm 3 clips (straight, 35° and 70°) and 2 bars included Straight 56 35° [ The short implants of Dentoflex were developed to be an alternative in the surgical/prosthetic planning when the absence of bone height availability in the posterior maxillary and mandibular regions is observed. It is also indicated for installation in the posterior region serving as support in protocol prostheses. Available in external hexagon prosthetic connections provided with mount and implant cover, morse taper available only with mount. DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM Used in natural root or in distal position of the bar-clip. 70° 57 SHORT Implant MORSE TAPER Implant EXTERNAL HEXAGON Cylindrical body High cutting power Double thread Mount and implant cover included Hexagon height: 1.0 mm Treatment of entire implant surface Implant Diameter Implant length 5,0 5,0 6,0 6,0 o 58 Has internal taper of 11.5o Available without prosthetic index Internal thread of 1.8 mm Mount included Implant cover not included Double thread Surface treatment on the entire implant body. MILLING SEQUENCE FOR SHORT EH IMPLANT Implant Diameter Implant length 5,0 5,0 6,0 6,0 7,0 MILLING SEQUENCE FOR SHORT MORSE TAPER IMPLANT SELECTION OF PLATFORM SWITCH COMPONENTS IMPLANT COMPONENT 5,00 4,30 6,00 5,00 DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM INDICATED FOR SINGLE AND MULTIPLE PROSTHESES 59 MIRUSCONE HEALING CAPS SHORT 1,20 1,20 Healing cap without Emergence profile USED FOR PRODUCING MULTIPLE SCREWED PROSTHESES Produced in titanium 32 N/cm Healing cap with emergence profile - SPE Installation torque: straight 32 N, angled 20N Installation torque of prosthesis retaining screw: 10N 2,20 HEIGHTS EMERGENCE PROFILE 2,0 - 3,0 - 4,0 - 5,0 - 6,0 5,0 - 6,0 Minimum occlusal distance: 4.5 mm Available straight or angled (17°, 22° and 30°) BELT HEIGHTS 1,0 - 2,0 - 3,0 1,20 1,20 Closed tray transfer 20 N/cm ANGLED MIRUSCONE 1,20 EH implant analog PERMANENT PROSTHESIS COMPONENTS DENTOFLEX | IMPLANTS SYSTEM UCLA BELT HEIGHTS ANGULATION 1,0 - 2,0 - 3,0 17o - 22o - 30o STRAIGHT AND ANGLED MIRUSCONE COMPONENTS Possibility of producing cemented or screwed prosthesis Available for all implant diameters Available with plastic body and ring or plastic body and ring in Cr-Co Open Tray Transfer 32 N/cm 1,20 1,20 32 N/cm 1,30 Metal Belt Available AR and Round Closed Tray Transfer 1,30 1,20 Healing Cap Plastic Belt Available AR and Round Round Metal Base Sleeve 1,20 Lab Screw (optional) Round Plastic Sleeve 1,20 Lab Screw (optional) Round Titanium Sleeve 1,20 DENTOFLEX | IMPLANTS SYSTEM Open tray transfer Available short, medium and long Lab Screw (optional) Analog 60 61 SHORT ESTHETICONE 32 N/cm USED FOR PRODUCING SINGLE OR MULTIPLE SCREWED Family PROSTHESES 2,20 Produced in titanium Installation torque: straight 32 N, angled 20N Installation torque of prosthesis retaining screw: 10N Minimum occlusal distance: 6.7 mm Available straight or angled (17°, 22° and 30°) BELT HEIGHTS 1,0 - 2,0 - 3,0 - 4,0 - 5,0 20 N/cm ANGLED ESTHETICONE BELT HEIGHTS ANGULATIONS AVAILABLE 1,0 - 2,0 - 3,0 17o - 22o - 30o Closed Tray Transfer Available AR and Round Open Tray Transfer Available AR and Round 1,20 1,20 1,20 Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) Metal Base Sleeve Available AR and Round 1,20 Lab Screw (optional) Plastic Sleeve Available AR and Round 1,20 Lab Screw (optional) Titanium Sleeve Available AR and Round 1,20 Lab Screw (optional) [ The SOLID family implants are characterized as single body implants. The Flex implants belong to the SOLID family and they are indicated for immediate mandibular loading, and the temporary implants whose prosthetic platforms have a ball attachment as overdenture retainer. DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM STRAIGHT AND ANGLED ESTHETICONE COMPONENTS Analog 62 63 SOLID FLEX Implant Implant TEMPORARY Produced in titanium grade IV Has square threads Excellent primary stability Indicated for lower immediate loading Prosthesis retaining screw supports 32 N Mount and implant cover included Single body: no GAP between implant and prosthetic component DIAMETER 2,50 INDICATED FOR TEMPORARY TOTAL PROSTHESIS RETAINING Indicated for restoration of small single prosthetic spaces Indicated for retaining prostheses fixed on implants Facilitated insertion: use of only one mill of 1,8 for bone preparation Cutting apex Requires Dentoflex O’ring insertion driver LENGTH 3,75 8,5 DIAMETER LENGTH 10,0 2,6 10 11,5 13 13,0 15 15,0 FLEX COMPONENTS 1,20 1,20 Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) Metal Base Sleeve Available AR and Round 1,20 Lab Screw (optional) Plastic Sleeve Available AR and Round 1,20 Lab Screw (optional) Titanium Sleeve Available AR and Round Spacer Washer 64 O’ring Capsule 1,20 Lab Screw (optional) Trunnion for cemented prosthesis Analog O’ring Transfer DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM Open Tray Transfer Available AR and Round Angled trunnion for cemented prosthesis Angulation of 15º 65 MIRUSCONE ZIGOFLEX Family USED FOR PRODUCING MULTIPLE PROSTHESES 32 N/cm Produced in titanium 2,20 Installation torque: straight 32N Installation torque of prosthesis retaining screw: 10N ZYGOMATIC IMPLANT Minimum occlusal distance: 4.5 mm Available straight or angled (17°, 22° and 30°) BELT HEIGHTS PRESENTED IN TWO MODELS: 1,0 - 2,0 - 3,0 Intrasinusal technique: Has thread on the entire active body of the implant. Exteriorized technique: Has no thread on the part in contact with the soft tissue External hexagon prosthetic connection Produced in titanium grade IV Implant diameter: 4.0 mm Mount and implant cover included [ The Dentoflex zygomatic implants are alternatives for graft reconstructions and for atrophic maxillary treatments using available bone areas in the maxilla using palatine access. The zygomatic implants are produced in two models, one for use in exteriorized technique (does not have thread on the implant region in contact with soft tissue) and the other is applied in the intrasinusal technique (with thread on the entire implant body). Available in diameters of 4.0 mm. Open Tray Transfer Closed Tray Transfer 1,20 1,20 1,20 Healing Cap LENGTH 35,0 – 37,5 – 40,0 – 42,5 – 45,0 – 47,5 – 50,0 – 52,5 – 55,0 ZYGOMATIC KIT Open Tray Transfer 1,20 Lab Screw (optional) Round Plastic Sleeve 1,20 Lab Screw (optional) Round Titanium Sleeve 1,20 Lab Screw (optional) DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM STRAIGHT MIRUSCONE COMPONENTS Only for placement of zygomatic implants. Case in polymer with internal tray and support in autoclavable silicone. Contains 15 items. 66 Analog 67 PROSTHESIS DRIVER REFERENCE GUIDE 32 N/cm USED FOR PRODUCING MULTIPLE PROSTHESES 2,20 Produced in titanium DRIVER Installation torque: straight 32N Installation torque of prosthesis retaining screw: 10N BELT HEIGHTS 1,0 - 2,0 - 3,0 - 4,0 - 5,0 STRAIGHT ESTHETICONE COMPONENTS Closed Tray Transfer Available AR and Round DENTOFLEX | IMPLANTS SYSTEM Open Tray Transfer Available AR and Round 1,20 1,20 Lab Screw (optional) Plastic Sleeve Available AR and Round SYMBOL INDICATION Digital hex driver 0.9 mm Ratchet hex driver 0.9 mm 0,9 Implant cover for External Hexagon Digital hex driver 1.20 mm Ratchet hex driver 1.20 mm 1,20 Implant cover and healing caps for IH and Morse Taper, transfer coping, prosthesis retaining miniscrew and lab screw Digital hex driver 1.30 mm Ratchet hex driver 1.30 mm 1,30 Temporary Trunnion, Ucla, Trunnion for Cemented Prosthesis Torque wrench hex driver 1.60 mm 1,60 Flat Component for Morse Taper Torque wrench hex driver 2.20 mm 2,20 Torque wrench hex driver 2.50 mm 2,50 O’ring and Temporary Implant Torque wrench hex driver 3.00 mm 3,00 Flex Component for Morse Taper Torque wrench hex driver 2.00 mm 2,00 Miruscone Estheticone 1,20 1,20 Healing Cap Available with and without emergence profile (6.0 and 7.5 mm) Metal Base Sleeve Available AR and Round DESCRIPTION 1,20 Lab Screw (optional) Titanium Sleeve Available AR and Round 1,20 Lab Screw (optional) Miscellaneous use Screwdriver Digital adapter for ratchet driver 4,00 DENTOFLEX | IMPLANTS SYSTEM ZIGOFLEX ESTHETICONE Used on torque wrench driver Analog 68 69 INSTRUMENTALS SINUS LIFT KIT The kit consists of: 1 Hammer / 1 Bayonet Chisel / 1 Retractor / 1 Special maxillary sinus separator / 1 Bone Condenser Beater / 5 Maxillary sinus curettes. SUMMERS COMPACTOR OSTEOTOMES • Indicated for elevation of the maxillary sinus, ridge expansion and future site preparation; • Its concave and cutting tip enables cutting, carrying and pushing the bone, reducing the risk of tearing the membrane; • Plastic protection included to reduce noise. Material – Stainless Steel with heat treatment Code: OTSUCJ 70 INSTRUMENTALS [ • Indicated for ridge expansion, its tip enables expansion in the anterior maxillary region with low bone thickness; • Plastic protection included to reduce noise. Material – Stainless Steel with heat treatment Code: OTSUCJM IRRIGATION KIT • Indicated for auxiliary irrigation independent of the motor; The instruments produced by Dentoflex aggregate a history of quality and commitment. The company is a pioneer in the implementation of innovations in the industry, offering reliable solutions in order to obtain security for surgery. the best raw materials market are used adding high resistance to corrosion, great finishing and excellent durability. • Equipped with manual control of quantity of flow of saline solution directed in all the necessary directions; DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM MODIFIED SUMMERS OSTEOTOME EXPANDERS • The entire system is autoclavable. Material – Body in anodized aluminum and silicone hose Code: IRRICJEXT 71 INSTRUMENTALS MOLT 2-4 SEPARATOR KEY HAND Used for separating flaps in implantodontic and Used in placing the Mini Orthodontic screw with the aid of periodontal surgeries. the Orthodontic driver Miniparafuso connected to Hand Material: Stainless Steel Key. CODE: DESCMOLT2 / DESCMOLT3 / DESCMOLT 4 Material - Stainless Steel and Polyacetal CODE: CHAVMAO BONE CALIPER Indicated for measuring bone thickness. Material – Stainless Steel CODE: PINCESP IMPLANT POSITIONER No 1 (5mm) 2 (7mm) 3 (12mm) No. 1 (5mm) 2 (7mm) 3 (12mm) It is used to provide parallelism in multiple dental implants. Material – Stainless Steel CODE: DIBEBAND15MM / DIVEBAND27MM / DIVEBAND312MM RETRACTOR WITH BRANEMARK HANDLE TACK KIT Indicating for retracting the upper and lower lips, both for Indicated for fixation of absorbable or non-absorbable photographs and for implant procedures. membranes. Material – Stainless Steel Material – Case, forceps and hammer, in stainless steel: CODE: AFSTBRAN titanium tacks. RETRACTOR SENN-MILLER It is used to ward off cheeks and flaps. SMITH RAMUS FORCEPS 23 cm Material - Stainless Steel Used in bone grafts, especially in the retromolar area. For CODE: AFSTSEN fracturing the bone block to be grafted. Material: Stainless Steel CODE: PINCSMRA DINGMAN BONE GRAFTING FIXATION FORCEPS 19 cm Used for holding bone graft for fixation of osteosynthesis screws Material: Stainless Steel CODE: PINCFIXENX19 72 TITANIUM ADSON BROWN FORCEPS DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM CODE: KITCTACH Used for manipulating soft tissue. Material - Titanium ASTMF-67 CODE: PINCADBRT 73 INSTRUMENTALS TUNGSTEN CARBIDE CRILE WOOD NEEDLE HOLDER 16cm ROUND SCALPEL FOR COUNTER ANGLE Used for suturing and the tungsten carbide prevents the • Developed for cutting the gingival tissue that covers the suture thread from escaping from the instrument. implant during the second surgical phase; Material – Stainless Steel • Indicated for cases with little gum; Cód. PORACRW016 • Available in sizes: 3.6, 4.0, 4.2, 4.6 and 5.1 mm. Material – Stainless Steel with heat treatment CASTROVIEJO CURVED SCISSORS 14 cm CODE: INCIBICA360 Used for removing suture and cutting soft tissue. Available in single surgical and prosthetic model of 10 to Material – Stainless Steel 60 N. Coupler for square connections, and dismountable CODE: TESOCASTCB14 ratchet that facilitates hygiene. TORQUE WRENCH Material – Stainless steel with heat treatment CODE: CHAVTORCIRPROT IMPLANT HOLDER FORCEPS Tip with titanium nitride treatment, indicated specifically in the handling of implants for coupling the mount. Material – Stainless Steel ZAUFAL-JANSEN BIARTICULATED PLIER 18 cm Used for osteotomies and cutting bone blocks in grafts. Material: Stainless Steel CODE: INCIALARJJ18 TREPHINE DRILL BIT DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM CODE: PINCPIMPANT • Available in two sizes, short for removal of bone grafts and long for removal of implants; • Laser markings Material – Stainless Steel with heat treatment CODE: BROCTRE1008 74 75 iglesias protocol 1 One inlet straight sleeve 2 Used in more distal implants when cantilever is not required. It has an inlet for the retractable arm and a thread located on the upper part to lock the retractable arm by using the screw. Miniscrew included for retaining miruscone that should be inserted with a torque of 10 N/cm 3 Miniscrew They are used between two implants. It has two inlets for the retractable arms and two threads located on the upper part to lock the retractable arms by using the screws. 4 They are used for fixing the sleeves with a torque of 10 N/cm with the aid of a hex driver of 1.20 and a prosthetic torque wrench DENTOFLEX | IMPLANTS SYSTEM 5 76 [ Seeking a practical and fast solution for the production of a bar for protocol, where the professional can obtain a reliable solution and reduce the time of entry of the prosthesis, DENTOFLEX presents the latest option for the production of protocol bar: DENTOFLEX ARTICULATED BAR – IGLESIAS PROTOCOL. Manufactured in commercially titanium ASTM F136, the ARTICULATED BAR is a total adjustable bar in its three movement axes (horizontal, vertical and lateral) according to the distance between the installed implants. The bar has extenders with plunger inside it, and these move in the horizontal direction allowing the bar to have a bigger or smaller length according to the distance between the installed implants. The plungers can also be easily curved to obtain the best direction on the curvature of the mandibular and/or maxillary arch. As the ARTICULATED BAR is mounted on miruscones (mini pillar), it allows a passive adaptation in the insertion of the protocol prosthesis. This ARTICULATED BAR enables a level of freedom of three-dimensional movement that, at the end of its mounting, after a mechanical fixation aided by a joint through the autopolymerizable resin, makes it rigid, enabling its installation in majority of the cases. The ARTICULATED BAR is indicated for most cases. With the use of the Articulated Bar, the production and acrylization of the prosthesis before the installation of the bar becomes possible, in cases of immediate or late loading or work together with the denture technician, with waxing and acrylization of the piece. An efficient, fast and practical solution is what the ARTICULATED BAR offers to the dental surgeon, thereby optimizing the time necessary for a prosthetic restoration on protocol implants. Plunger The plunger together with the extender make up the rod (retractable arm). They are used between two implants in areas where there is no curvature of the arch. If necessary, due to a space smaller than the size of the extender between the implants, both can be sectioned with a carborundum disk in the size ideal for the available space. Double inlet straight sleeve Screw They are used for locking the retractable arm. They should be used on the sleeve or on the extender with a torque of 20 N/cm, with the aid of a hex driver of 1.20 and a prosthetic torque wrench 6 Extensor The extender together with the plunger make up the retractable arm. They are used between two implants in areas where there is no curvature of the arch. If a space smaller than the size of the extender between the implants is required, both can be sectioned with a carborundum disk in the size ideal for the available space. The extender has two threads (use only one) used for the perfect lock of the system. It has a ball that should be introduced into one of the sleeve inlets. THE ARTICULATED BAR FOR 6 IMPLANTS CONTAIN: 1 One inlet straight sleeve: 2 items 2 Double inlet straight sleeve: 4 items 3 Miniscrew: 6 units 4 Screw: 15 units 5 Plunger: 5 items 6 Extender: 5 items DENTOFLEX | IMPLANTS SYSTEM ARTICULATED BAR ARTICULATED BAR 77 ARTICULATED BAR PREFABRICATED ARTICULATED BAR FOR PROTOCOL WITH CANTILEVER With a smaller length of bone availability when there is lack of bone height at the posterior region of the dental arch, the space available for insertion of implants becomes evidently more restricted, which forces the dental surgeon to install the implants closer to each other, and the bar for protocol must contain a cantilever in order to have a biomechanical gain in occlusion and greater resistance of the prosthesis to the occlusal loads. Contemplating this, Dentoflex developed an Articulated Bar with bilateral cantilever, and this bar specifically containing insertions of the more lingualized extenders, which facilitates mounting of the bar with a closer distribution between the implants. As accessory, one rod with titanium balls can be used between the implants in very close positions, which may be easily cut into a suitable size between two implants. The length of the cantilever can be cut or curved, following the path of the alveolar crest. ADVANTAGES • Up to 50%* reduction of prosthesis production time • Complete adaptation of the Bar to the prosthetic component • Guaranteed passivity of the prosthesis • Up to 45%* reduction of the final cost of the prosthesis (in the domestic market) • Fully adaptable bar in the horizontal, vertical and lateral direction • Bar produced in titanium ASTM F136, lighter in comparison to the traditional cast bar. CLINICAL CASE Straight sleeve for cantilever They are used in more distal implants, in cases that require cantilever. It has an inlet for the retractable arm and a thread located on the upper part to lock the retractable arm by using the screw. Kit for short distances short double inlet sleeve Upper view of the mounted articulated bar. Bar installed on micruscones (mini pillars) and joined with resin. Installation of protocol prosthesis with the articulated bar. Verification of the space for hygiene. Final radiography: absence of gap and tension. The set of balls is used together with the double inlet sleeve (messial– distantal) when the distance between the centers of the miruscones is lesser than 11 and greater than 8 mm. When the distance is between 6.5 and 8 mm, the double inlet sleeve should be used for short distances (lingual). set of balls 78 Mounting of bar on plaster model before surgery, executed with surgical guide. DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM OPTIONAL ITEMS FOR ARTICULATED BAR 79 KITS KITS PROSTHESIS OVER IMPLANT KIT SURGICAL KIT For placement of prosthesis over implants of For placement of implants with up to 6.00 mm. Contains Enables the use of the internal, external, morse taper, • Case with cover flex, cylindrical body, tapered and osseocompressive • Torque Wrench* prosthetic interface systems. • Short handle for torque wrench driver Case in polymer with internal tray and support in • Medium handle for torque wrench driver autoclavable silicone. • Long handle for torque wrench driver the Dentoflex system. • Torque wrench drivers: - Medium hex of 1.2 ADAPTER FOR PRE-MOUNTED LONG EH SINGLE SURGICAL AND PROSTHETIC TORQUE WRENCH OF 10 TO 60 N HELICAL SPEAR DRILL BIT 2.30 MM MEDIUM DIGITAL DRIVER 1.00 MEDIUM DIGITAL DRIVER 1.20 - Medium square of 1.3 HELICAL DRILL BIT 2.60 MM ADAPTER FOR PRE-MOUNTED SHORT EH TRI-HELICAL DRILL BIT 2.90 MM TRI-HELICAL DRILL BIT 3.20 MM TRI-HELICAL DRILL BIT 3.40 MM TRI-HELICAL DRILL BIT 3.70 MM: TRI-HELICAL DRILL BIT 4.00 MM DENTOFLEX | IMPLANTS SYSTEM - Short hex of 1.2 MEDIUM DIGITAL DRIVER 1.30 FOR SQUARE SCREW SHORT DIRECTION INDICATOR LONG DIRECTION INDICATOR SHORT INTERMEDIATE FOR COUNTER-ANGLE FOR IH IMPLANT - Extra long hex of 1.2 - Extra long square of 1.3 - Medium screwdriver - Medium estheticone of 2.2 - Medium O’ring of 2.5 *Check the model during purchase. TRI-HELICAL DRILL BIT 4.20 MM LONG INTERMEDIATE FOR COUNTER-ANGLE FOR IH IMPLANT TRI-HELICAL DRILL BIT 4.50 MM SHORT INTERMEDIATE FOR RATCHET 2.50 MM TRI-HELICAL DRILL BIT 5.00 MM LONG INTERMEDIATE FOR RATCHET 2.50 MM COUNTERSINK DRILL BIT SHORT DRIVER FOR IT IMPLANT FOR RATCHET HELICAL TAPERED DRILL BIT 3.50X8.5 MM LONG DRIVER FOR IT IMPLANT FOR RATCHET HELICAL TAPERED DRILL BIT 3.50X10.0 MM SHORT DRIVER FOR IT IMPLANT FOR COUNTERANGLE Intended for use in bone graft placement surgeries. LONG DRIVER FOR IT IMPLANT FOR COUNTERANGLE Contains HELICAL TAPERED DRILL BIT 3.50X11.5 MM HELICAL TAPERED DRILL BIT 3.50X13.0 MM HELICAL TAPERED DRILL BIT 3.50X15.0 MM HELICAL TAPERED DRILL BIT 3.75X8.5 MM HELICAL TAPERED DRILL BIT 3.75X10.0 MM HELICAL TAPERED DRILL BIT 3.75X11.5 MM HELICAL TAPERED DRILL BIT 3.75X13.0 MM HELICAL TAPERED DRILL BIT 3.75X15.0 MM HELICAL TAPERED DRILL BIT 4.30X8.5 MM SHORT DRIVER FOR MORSE TAPER IMPLANT FOR RATCHET LONG DRIVER FOR MORSE TAPER IMPLANT FOR RATCHET SHORT DRIVER FOR MORSE TAPER OC IMPLANT FOR COUNTER-ANGLE HELICAL TAPERED DRILL BIT 4.30X10.0 MM LONG DRIVER FOR MORSE TAPER OC IMPLANT FOR COUNTER-ANGLE HELICAL TAPERED DRILL BIT 4.30X11.5 MM MOUNT HOLDER FOR COUNTER-ANGLE HELICAL TAPERED DRILL BIT 4.30X13.0 MM DRILL BIT EXTENDER HELICAL TAPERED DRILL BIT 4.30X15.0 MM CALIBRATED PROBE HELICAL TAPERED DRILL BIT 5.00X8.5 MM SMALL SQUARE FIXED T DRIVER HELICAL TAPERED DRILL BIT 5.00X10.0 MM CASE FOR SURGICAL KIT BONE GRAFT KIT • Case with cover • Mounting base • Hand driver • Philips Screwdriver for hand driver and counter-angle • Drill bit of 1.25 mm for counter-angle and handpiece • Drill bit of 1.45 mm for counter-angle and handpiece DENTOFLEX | IMPLANTS SYSTEM COMPOSITION OF THE SURGICAL KITS - Hex of 0.9 HELICAL TAPERED DRILL BIT 5.00X11.5 MM HELICAL TAPERED DRILL BIT 5.00X13.0 MM HELICAL TAPERED DRILL BIT 5.00X15.0 MM 80 81 HYGIENE bristles for cleaning racks, knurls and fittings. b. Do not prematurely open the autoclave in order d. Never use straws or steel sponges and abrasive to avoid rapid condensation. products in order to not damage the instruments. c. Do not quickly open the autoclave; let all the e. Do not accumulate the instruments in large steam out before the drying cycle is complete. quantities on top of each other in order to avoid d. In a conventional autoclave, the instrument should deformation of the smaller and delicate pieces. stay for 30 minutes after reaching a temperature of Always handle few pieces at a time. 121ºC. In a high-vacuum autoclave, this time should f. Cleaning by ultrasound, if used, should have a be 4 minutes after reaching a temperature of 132ºC. solution for washing heated to at least 45ºC, and e. Thoroughly and periodically clean the autoclave the instruments should be placed in the open to remove dirt and eventual excess rust (iron oxide). position. Three to five minutes of immersion at a Tip: use two instrument drying cycles frequency of 35 Kilohertz is the sufficient time for cleaning the instruments. There is still the need to brush the knurled parts and joints. NOTE Many executed electrochemical recordings are not RINSING HYGIENE AND STERILIZATION PROCEDURES carefully neutralized, causing premature oxidation, It is the removal of chemical residues, detergents and also the recording cannot be executed on and foam still present on the instruments. any part of the surface of the piece because it a. Always use distilled, deionized or demineralized may cause infiltrations of the corrosive product. water. If the water is heated, its temperature should Recordings in the form of “scratches” with sharp be between 40ºC and 45ºC. objects on the piece are completely wrong b. Never use salt solutions, especially sodium because the characteristics of the stainless steel hypochlorite and saline solution, disinfectants, are only suitable for surgical use due to polishing oxygenated water or alcohol to clean or rinse the and treatment on its surface, therefore any surgical instruments. aggression to it will result in oxidation and even PRIOR HYGIENE OR DESCALING It is the removal of organic material from the instrument, without direct manual contact. It should commence as quickly as possible after its use. a. The person in charge of the task should be equipped with the individual protection equipment (gloves, mask, goggles, apron, cap, etc.). DRYING b. Use Sodium hypochlorite solution 1% (Milton It is the removal of residual water and moisture after solution) for 20 minutes. the rinsing procedure. Never let the instrument dry c. Rinse only once directly in jet of water, without “naturally” in order to avoid white and yellow stains. handling the surgical instruments. Always use soft and absorbent fabric (compresses for example) or moisture-free compressed air. equipped with the individual protection equipment (gloves, mask, goggles, apron, cap, etc.). WASHING b. Use enzymatic solution, at the concentration and It is the mechanical removal of dirt from the surgical STERILIZATION time of exposure established by the manufacturer instruments by manual brushing or vibrations It is the procedure that aims at the complete of these chemical solutions. produced by ultrasound. elimination of microorganisms (viruses, bacteria, c. Rinse only once directly in jet of water, without a. Always use distilled, deionized or demineralized microbes and fungi), be it in the form of vegetation handling the surgical instruments. water for this procedure. If the water is heated or spores. Sterilization by Saturation Steam under to facilitate cleaning, the temperature should be Pressure – Autoclave. between 40ºC and 45ºC. a. Use distilled, demineralized or deionized water b. Use neutral soap 1% or neutral detergent, both in order for the resulting steam to be free from with pH of 7.0. contaminants. If necessary, the autoclave should c. Always use brushes with soft natural or nylon also have suitable filters to retain contaminants. DECONTAMINATION It is the cleaning of microorganisms in vegetation form that offer occupational risks. 82 a. The person in charge of the task should be DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM loss of the original resistance. 83 BETApro® PUREZA Pure phase of Beta – Tricalcium Phosphate (ß – TCP) O BETApro® é um material sintético de altíssimo grau de pureza (99%), para aplicação como substituto ósseo em operações de implante ou reposição de perda óssea. A fase pura que compõe o BETApro® é o Beta-Tricálcio Fosfato (B-TCP) pertencente à família das apatitas conhecida por sua semelhança com as diversas formas de matrizes minerais ósseas humanas. ESTABILIDADE DENTOFLEX | IMPLANTS SYSTEM POROSIDADE 84 No BETApro® a estrutura cristalina e química dos grãos, bem como sua porosidade (20 a 600um), foram projetadas para se assemelhar aos componentes de fosfato de cálcio que compõe a matriz mineral do osso humano. Essa faixa de porosidade garante que os grãos não tenham uma absorção prematura pela ação dos macrófagos e cria um ambiente favorável para a ancoragem e proliferação de osteoblastos. A morfologia de superfície (Figura 2) favorece a permeação dos fluídos biológicos em toda a superfície enxerto. INDICAÇÕES [ BETApro® is an osteoconductive bone substitute, which consists of high purity beta-tricalcium phosphate (beta-TCP). BETApro® should be used as a bone substitute in cavities or empty spaces that require bone regeneration (resulting from surgery, trauma or degenerative process). Once implanted, the BETApro® provides a supporting structure that stimulates bone formation. The BETApro® is then absorbed and later replaced by natural bone during the regeneration process. BETApro® is supplied in granules and blocks that have a structure similar to human bone. The interconnected porous structure of BETApro® acts as an osteoconductive matrix for the growth of bone cells and blood vessels. O enxerto ósseo BETApro® é indicado para o preenchimento e restauração dos defeitos ósseos nos seguintes casos: • Reconstruções Bucomaxilofacial; • Preenchimento das cavidades ósseas de regiões decorrentes de lesões, doenças degenerativas e perdas ósseas; • Preenchimento de crista alveolar decorrentes de atrofias; • Alargamento do seio e base do seio maxilar; • Defeitos após remoção cirúrgica e osteotomias corretivas; • Lesões intra-ósseas periodontais; • Lesões periapicais; • Substituto de defeitos ósseos cirúrgicos não infectados; • Cirurgia plástica e reconstrutiva seja de fragmentos removidos cirurgicamente ou áreas lesadas; • Pseudoartroses, artrodeses inclusive vertebrais; • Operações de implantes como substituto ósseo. Fig. 1 – Micrografia da estrutura sinterizada do BETApro® Fig. 2 – Enxerto Granulado BETApro® SOLUBILIDADE Com a ação degradativa e oxidativa dos fluídos biológicos e células progenitoras ósseas, o método de síntese do BETApro® garante uma solubilidade homogênea ao longo de todo o enxerto criando um gradiente constante de íons, cálcio e fósforo utilizados no anabolismo das células ósseas formando a matriz extracelular mineralizada (osso neoformado). REFERÊNCIA E DESCRIÇÃO BIOMBETA10F Beta - Pro GRAN 150-500UM - 1,0 GR (Grânulos Finos em embalagem de 1,0 grama) BIOMBETA05 Beta - Pro GRAN 150-500UM - 0,5 GR (Grânulos Finos em embalagem de 0,5 grama) BIOMBETA10 Beta - Pro GRAN 500-1000UM - 1,0GR (Grânulos Grosso em embalagem de 1,0 grama) DENTOFLEX | IMPLANTS SYSTEM No início da regeneração, no processo inflamatório, o material deve permanecer estável. Não deve quebrar, dissolver-se e perder estabilidade devido à ação de fluídos e células locais. A microestrutura do BETApro® provinda de sua alta cristalinidade foi projetada para resistir a essa ação do sistema local nos primeiros dias, evitando assim desintegração prematura em micropartículas, impedindo a atividade dos macrófagos que intensificam reações de defesa imunológica prejudicando e retardando a regeneração óssea. A Figura 1 ilustra a microestrutura dos grãos sinterizados o que confere maior estabilidade ao enxerto. 85 86 1 – Almeida, J.M.V. – Caracterização in vivo de implantes de titânio submetidos a três diferentes tratamentos de superfícies: ataque ácido, anodização e recobrimento com hidroxiapatita – Tese de Mestrado, 108 pgs. - 2003 2 -Andrade, P. C. Carga imediata em implante unitário: relato de um caso, 2009. Disponível em: http://www.scielo.br; 3 – Andrade, P.C.; França, F.M.G.; Silva, A.C.B.R.– Levantamento Bilateral dos Seios Maxilares com Colocação Imediata pela Técnica da Janela Lateral Relato de um caso – 2010 4 - Brosco, H.B. Precisão de adaptação de intermediários transmucosos unitários em sistemas nacionais de implantes compatíveis com hexágono externo. - Tese apresentada a Faculdade de Odontologia de Bauru, da Universidade de São Paulo, como parte dos requisitos para obtenção de título de Livre-docência, 100 pgs. Bauru, 2001. 5 – Bisognin, E.D.G. – Avaliação da adaptação e capacidade de infiltração microbiana na interface implante-pilar protético em diferentes sistemas de implantes – Tese de Mestrado, 82 pgs. – 2009 6 - Bisognin, E. D. C.; Dias, Mello,E. C. L. C. ; Soares, G. A.; Vidigal , G. M.J. Avaliação da adaptação e capacidade de infiltração microbiana na interface implante/pilar / Evaluation of fit and bacterial leakage at implant-abutment interface at different implant systems, ImplantNews; 7(6): 801-810, 2010. ilus, tab, graf 7 - Bottecchia, M. O laser terapêutico no tratamento da dor em pacientes portadores de neoplasias malignas de cabeça e pescoço. Tese de Mestrado, 98 pgs. – 2006 8-Carvalho, D. R. ; Magro Filho, O.; Carvalho, A. C. P. Implante de matriz óssea humana desmineralizada em forma de gel (Grafton DBM Gel) em cavidades ósseas e tecido conjuntivo subcutâneo: avaliação histológica em ratos / Demineralized bone matrix gel (Grafton DMB Gel) implant in bones cavities and subcutaneous connective tissue: histological evaluation in ratsRBP Rev. bras. implantodont. protese implant; 10(37): 48-55, jan.-mar. 2003. 9 – Comar, K.A. – Relação entre desgaste e aumento de temperatura e carga durante a fresagem em Implantodontia – Tese de Mestrado, 96 pgs. - 2006 10- Coutinho, D. Karilanyy - Biomecânica e Otimização Topológica com H-Adaptividade em Implantes Dentários Nitretados a Plasma em Cátodo Oco - Tese de Doutorado, UFRN, 2014. 11– Dias, E.C.L.C.M. – Análise descritiva do grau de adaptação de pilares protéticos a implantes osseointegráveis e seu efeito na infiltração bacteriana: um estudo in vitro – Tese de Mestrado 96 pgs. – 2007 12 - Dias EC; Bisognin ED; Harari ND; Machado SJ; da Silva CP; Soares GD; Vidigal GM. Evaluation of implant-abutment microgap and bacterial leakage in five external-hex implant systems: an in vitro study. Int J Oral Maxillofac Implants; 27(2): 346-51, 2012 Mar-Apr. 13 - Filho, H.S. Eduardo, Plataforma dos implantes dentários - Monografia apresentada ao Centro de Pós Graduação da Academia de Odontologia dp Estado do Rio de Janeiro para obtenção do grau de Especialista em Odontologia - 2011 Área de Concentração: Implantodontia 14– Giannetto, C. Efeitos do laser em baixa intensidade em enxertos de tecido ósseo alógenos particulados em fêmures de coelhos, Tese de Mestrado, 97 pgs. – 2011 15 - Gomes, M.F. et al. ESTUDO COMPARATIVO DE DIFERENTES MEMBRANAS OCLUSIVAS NO REPARO ÓSSEO (V Reunião de Pesquisa e II Seminário de Iniciação Científica da F.O.U.S.P., 11 a 13/11/97). ( 1 páginas 0 ref. 0 f.) RPG: Rev. Pós-Graduação Fac. Odont. USP - Ano: 1997 16- Lacerda, J.R.Evelyn; Lacerda, M Hesio; Salomão Munir Invaginação de tecido conjuntivo após levantamento do seio maxilar, uso de biomateriais e implante tardio: Resolução cirúrgica de um caso clínico - Revista Implant News, 9 (6): 843850, nov-dez, 2012 17 - Lacerda, J.R. Evelyn; Lacerda, M. Hésio; Cruz, Mauro - Explantação, reimplantação e regeneração tecidual guiada - Revista Implant News, 10 (5): 629-633, set-out, 2013 18 - Lacerda, J.R. Evelyn; Lacerda, M. Hésio - Preservação da arquitetura gengival em região estética por meio de compensações nas seguintes situações: alvéolo cicatrizado, alvéolo fresco íntegro e alvéolo fresco comprometido. - Revista implant News, 12 (3): 313-322, maijun, 2015 19 –Lepera, H. Verificação da Dimensão longitudinal obtida de implantes dentários de titânio, fixados em mandíbulas humanas maceradas edêntulas, comparando imagens tomográficas (panorâmica, convencional r computadorizado) - Tese apresentado à Faculdade de Odonto- logia, Campus São José dos Campos, Universidade Estadual Paulista, como parte dos requisitos para a obtenção do título de Doutor, área de concentração Radiologia 2001 20 - Lima GM; Soares MS; Penha SS; Romano MM. - Comparison of the fracture torque of different Brazilian mini-implants. - Braz Oral Res; 25(2): 116-21, 2011 Mar-Apr. 21 - Lima,G.M.A. ; Soares, M.S. Mensuração do torque por torção de mini-implantes nacionais Faculdade de Odontologia da Universidade de São Paulo, USP, SP –2012. 22 - Loureiro, F.L.; Oliveira, H.B.J.; Carvalho, P.E.G.; Ferreira, F.A.C. Mini-implantes ortodônticos: quais os tamanhos mais vendidos? - Revista de Odontologia da Universidade Cidade de São Paulo 2008 set-dez; 20(3): 254-60 23 - Maeda, S. T. Avaliação microscópica da resposta tecidual de cavidades cirúrgicas em fêmures de coelho preenchidas com sulfato de cálcio / Microscopy evaluation of tissue reaction to surgicals cavities on the rabbits femurs with calcium sulfate - Bauru; s.n; 2005. 97 p. ilu 24 - Maeda ST; Bramane CM; Taga R; Garcia RB; de Moraes IG; Bernadineli N. Evaluation of surgical cavities filled with three types of calcium sulfate. J Appl Oral Sci; 15(5): 416-9, 2007 Oct. 25 – Magalhães, G.M.S. – Efeito do ranelato de estrôncio sobre o tempo de osseointegração de implantes dentários de titânio instalados em tíbia e em fêmur de coelhos – Tese de Mestrado, 69 pgs. 2009 26 - Martins, J. E.; Feltrin, P. P.; Zanetti, R. V.; Moreira, L. A.; Sonoda, H. M. Avaliação da precisão de modelos obtidos a partir de diferentes transferentes para implantes HE / Evaluation the accuracy of models obtained through different transfers for implants HE Rev. Assoc. Paul. Cir. Dent; 62(3): 232-240, maio-jun. 2008. ilus, tab 27 - Marzola, C. et al. Implantes de biohapatita + osseobond + membrana reabsorvível Dentoflex + aglutinante Dentoflex - apresentação de casos clínico-cirúrgicos ( 13 páginas 101 ref. 23 f.) Rev. Bras. Ciênc. Estomatológica / FAFEOD - Ano: 1996 28 - Marzola, C. et al. Neurectomia do feixe vásculo-nervoso mentoniano com implante de biomateriais - estudo microscópico ( 30 páginas 80 ref. 16 f.) Rev. Odont. Acad. Tiradentes Odont. - Ano: 2006 29 - Mendonça, G. Estudo comparativo do ajuste entre implantes e intermediários de seis diferentes sistemas. - Dissertação apresentada no programa de Pós-graduação em Odontologia, pela Faculdade de Odontologia da Universidade Federal de Uberlândia, como requisito parcial para a obtenção do título de mestre. Área de concentração: Reabilitação Oral. Orientador: Prof. Dr. Alfredo Júlio Fernandes Neto. Uberlândia, 2003 30 -Moreira LA1, Santos MT, Campos VF, Genovese WJ -.Efficiency of laser therapy applied in labial traumatism of patients with spastic cerebral palsy. Braz Dent J. 2004;15 Spec No:SI29-33 31 - Moretto , A.N., Mulatinho,J. Implantes Curtos – Uma Alternativa Viável e Segura em Reabilitações em Regiões Posteriores - Revista Catarinense de Implantodontia, Ano 10, 12, 34-36, junho 2010 32 – Moretto Neto, A.; Lacerda, H.; Mulatinho, J. – Barra articulada pré-fabricada da Dentoflex – uma nova opção de barra para próteses do tipo protocolo – Revista Catarinense de Implantodontia, v. 12 p. 46-48, 2012 33 – Mulatinho, J. Taga, R. Aplicação de Osseobond e Biohapatita em caso de colocação imediata de implante de titanio. Revista Brasileira de Implantodontia, V.4, pg 11-15, 1996 34 - Mulatinho, J.; Borges, L. F. A., Mandacaru, E. A., Reabilitação estética e funcional com utilização de implantes orais em paciente desdentado total. BCI. Revista Brasileira de Cirurgia e Implantodontia, V.8, pg 94-100, 2001 35 – Mulatinho J., Campos M.E., Martins O.Z., Franzi S.A. Prótese Toronto ou Protocolo Branemark: Relato de Caso Clínico - Revista Implant News, 2 (5): 513-518, set-out, 2005 36 - Mulatinho, J. - Implantes de corpo único e função imediata. Revista Catarinense de Implantodontia, V.8, pg 6-8, 2008 37 - Muller A., Silva,A.C.B. , Schimidt L. Implante Unitário Submetido à Carga Imediata RGO, 52(1): 27-41, jan/fev/mar, 2004 38 – Osdeberg, A. – Os sistemas de microparafusos ortodônticos (MPO) disponíveis no mercado brasileiro, 69 pgs – 2009 39 - Restrepo, L. L. V.; Marzola, C.; Consolaro, A.; Pereira, A. A. C.; Toledo , J. L.F.; Andreo, J. C. Avaliação de implantes de osso bovino liofilizado Osseobond e membrana reabsorvível de osso bovino liofilizado: estudo microscópio em tíbia de ratos (wistar albinus) / Evaluation of cattle bone implants freeze dried Osseobond and absorbable membranes of cattle bones freeze dried: microscopy study of rats tibia - Rev. bras. Implant; 4(1): 8-14, jan.-fev. 1998. ilus, DENTOFLEX | IMPLANTS SYSTEM DENTOFLEX | IMPLANTS SYSTEM REFERENCES References with DENTOFLEX brand products (in alphabetical order) 87 REFERENCES DENTOFLEX | IMPLANTS SYSTEM 88 40 - Rossa, R. MEMBRANAS BIOLÓGICAS REABSORVÍVEIS (V Reunião de Pesquisa e II Seminário de Iniciação Científica da F.O.U.S.P., 11 a 13/11/97). ( 1 páginas 0 ref. 0 f.) RPG: Rev. PósGraduação Fac. Odont. USP - Ano: 1997 41 - Sanches, M. P. R..; Marzola, C.; Taga, R. - Avaliação microscópica em ratos (wistar albinus) de implantes de matriz de osso bovino liofilizado Biograft + proteína morfogenética + membrana reabsorvível de osso bovino liofilizado Dentoflex / Microscopical evaluation of rat’s (wistar albinus) tibia grafted with demineralized bone matrix (BiograftO) + bone morphogenetic protein + cortical bovine bone barrier (DentoflexO) - BCI; 7(27): 32-40, jul.-ago. 2000. ilus, tab 42 – SIMÃ0, R.A., CALHEIROS, F.C., AGRA, C.M., PINTO, P.G. Utilização da resina bis-acrilica na confecção de uma barra-clip pela técnica da fundição direta - Journal of Biodentistry and Biomaterials São Paulo, V.2, p. 41-45, Set 2011/Fev. 2012 43 - Simonetta D’Ercole, DDS, PhD1, Antonio Scarano, MD, DDS1, Vittoria Perrotti, DDS, PhD1, Jorge Mulatinho, DDS2, Adriano Piattelli, MD, DDS1*, Giovanna Iezzi, DDS, PhD1, Domenico Tripodi, MD, DDS, Implants With Internal Hexagon and Conical ImplantAbutment Connections: An In Vitro Study of the Bacterial Contamination - Journal of oral implantology, V. 40, nº 1, pg. 31 – 36, 2014. 44 - Souza, A.A.F., Castro, L.V.C., Carga Imediata simultânea em maxila e mandíbula. Implant News, V. 4, n 5, pag. 523-528, Set/Out 2007 45 – Souza, A.A. – Avaliação das tensões geradas por prótese obturadora maxilar implanto retida por meio de análise de elementos finitos – Tese de Doutorado,USP - 92 pgs. – 2012 46 - Taga, R. Avaliação histológica, radiográfica e morfométrica da reparação de defeito ósseo perene em crânio de cobaia tratado com mistura de osseobond e biohapatita e membrana absorvível de cortical óssea bovina TAGA, R. et al. ). 10 páginas 36 ref. 24 f.) JBE: J. Bras. Endo/Perio - Ano: 2000 47 -Tamashiro, N.S – Biocompatibiidade De Implantes De Titanio Em Tibias De Coelhos. Tese de Mestrado,Instituto de Ciencias Biomédicas USP, 120pgs - 2001. 48 - Tessare, P.O.Jr. Sucesso de implantes osseointegrados no complexo maxilo-mandibular: estudo de 140 Implantes – Tese de Mestrado, 78 pgs. 2006 49 - Vidigal Junior, G. M. Avaliação histomorfométrica do grau de osseointegração de implantes de titânio comercialmente puro e de implantes recobertos com hidroxiapatitas / Histomorphometry available to osseointegration degree in commercially pure titanium implants and hydroxyapatite coated implants - Rio de Janeiro; s.n; 1994. 152 p. ilus, tab. 50 - Vilela, E.C. C. Monitoramento térmico e morfológico das superfícies de implantes orais durante a irradiação com laser de Nd:YAG ou GaAIAs - Dissertação apresentada como parte dos requisitos para obtenção do Grau de Mestre Profissional na área de Lasers em Odontologia – IPEN – USP – 2004 51 - Zampieri, M. J. P.; Cogo, J. C.; Genovese, W. J.; Barbosa, A. D. Ação bactericida da terapia fotodinâmica (AsGaAI) sobre bactérias St mitis St sanguis, “in vitro” / Photodinamic terapy in bacterias st mitis st sanguis, “in vitro” - Rev. Bras. Implant; 9(2): 16-7, abr.-jun. 2003. Ilus 52 - Zenóbio, E.G. et al. ASSOCIAÇÃO DE BIOMATERIAIS DE IMPLANTES NA REABILITAÇÃO ORAL ( 4 páginas 15 ref. 12 f.) Rev. Bras. Implantodontia / IBI - Ano: 1997 ANNOTATIONS DENTOFLEX | IMPLANTS SYSTEM 89 Dentoflex Com. e Ind. de Materiais Odontológicos Ltda. R. Lino Coutinho, 634 - Ipiranga São Paulo, 04207-000 Tel.: (11) 2065-2155 • 0800 774 2155 • Fax: (11) 2065-2153 [email protected] • www.dentoflex.com.br
Documentos relacionados
quadril - Excellence Implantes
El Unique Next posibilita la realización de cirugías con cualquier cotilo MDT, sea él cementado o sin cemento, con inserto de cerámica o polietileno y cabezas femorales de cerámica o metal. Unique ...
Leia mais