Ritmo - ALMATECHNIK
Transcrição
Ritmo - ALMATECHNIK
en gl . Ritmo 05 Ex ® The explosion-proof dosing pumps Ritmo®-05 in the classification Ex II 2G Ex mb eb PXB IIB T4, approved by EC-EX Directive 94/9 / EC Dosierpumpen exakt nach Ihren Bedürfnissen Ritmo®-05 metering pumps in explosion-proof version are designed for dosing of liquid and gaseous media in the gas class 2B in hazardous areas of zone 1 and 2 (with the exception of gases of Class IIC – such as hydrogen; acetylene or carbon disulphide). • Metering pumps in full-PTFE-design The explosion-proof security is based on protection class EEx p and consists of a pump housing with Ex e approval and an Ex p control unit with rinsing and pressure control function, proportional valve technology with automatic leakage compensation and an decoupled PTFE pump head from the Ex housing. • Pulsfree diaphragm pumps • Diaphragm metering pumps with positively controlled valves • Heated and cooled metering pumps • Vacuum metering pumps • Filling pumps Approval according to the EC Directive 94/9 / EC. • Multi channel pumps Classification Ex II 2G EX eb mb pxb IIB T4. • Sampling pumps Use in the environment with the classification ATEX II 2 GD T4 (zone 1 and 2) Housing in in IP54 version. From Ex-housing decoupled PTFE pump head to avoid intrusion of dosing liquid or gas into the Ex-proof housing. • Mixing pumps • Metering pumps in master-/ slave configuration • Reflow splitter Flushing connection for the creation of a housing overpressure (max. 12 mbar) with air / compressed air or nitrogen (flushing volume 50 liters). • Pulse generator In Ex-housing integrated Ex p control unit with rinsing and pressure control function and automatic leakage compensation. • specialized acid pumps Ex-terminal box is laid out for the power supply 230 VAC. • pH-controlled pumps • Gasmetering-/ gasmixing pumps • Explosion-proof pumps Process capability and automation via analog (4-20mA) and digital interfaces (RS232), with interface relay and in fixed installations on Ex-terminal box. Compressed air connection with proportional valve technology for the pressurization of the pump housing. Pump in version R05-Ex-TH with thermal fluid is up to 120°C heatable (<temperature class T4) or with a cooling medium cooled. ® Ritmo 05 Ex s from g pump Meterin – 480 ml/min in 30 µl/m Maybachstr. 11 · 70771 Leinfelden-Echterdingen · Germany Tel. +49 (0)711/9975-5427 · Fax +49 (0)711/9975-5428 www.finkct.de · [email protected] Ritmo 05 Ex ® Specifications: Pump type 05/30 05/120 05/250 max. metering capacity (ml/min) 30 min. metering capacity (µl/min) 30 max. stroke frequency (strokes/min) ca. 50 max. pressure inlet (bar) 4 max. pressure outlet (bar) 4 Stroke volume (µl) 600 min. stroke duration (sec.) 1,2 max. stroke duration (sec.) 1190 Repeat accuracy (%) <1 Vacuum at inlet (mbar) 20 Vacuum at outlet (mbar) 0 Max. viscosity (mPas) 200 Max. viscosity (mPas) ** 400 Max. medium temperature (°C/°F) Material, pump head Material, diaphragm Material, valves Input voltage Power input safety class Ambient temperature (°C/°F) max. dimensions (L x W x H) (mm) 120 250 120 250 ca. 46 ca. 53 2 1,5 2 1,5 2600 4700 1,2 1,2 1300 1080 <1 <1 20 20 0 0 500 500 800 800 120°C/248°F (<T4) PTFE PTFE PTFE 90-264VAC / 47-63Hz max. 45 W IP 54 0-40°C/32-104°F 290x250x250 The above rated values have been carefully determined with reference fluid. If other fluids are metered, the above values may differ minimal. ** max. viscosity with using software module R05-AK 05/480 480 480 ca. 51 1,5 1,5 9400 1,1 1190 <1 20 0 500 800 (1) (2) EG - Ba umuste rprüfbes Geräte und Sch Bereic hen- Ricutzsysteme zur htlinie bestimmu 94/9/EG EG-Ba ngsgem umusterp äßen Ver rüfbesc wendung heinigung in explos snumm ionsgefäh er rdeten EPS 15 (4) ATEX Gerät: 1 078 X (5) Dosierpu Hersteller mpe Typ : Ritmo R0 (6) Fink Ch Anschr 5-... Revision em +Te ift: :0 c GmbH (7) Mayba & Co. KG Die Bau chstraß e 11, 707 zu dieserart dieses Ge räte 71 Leinfe Baumu lden-Echt sterprü s sowie die (8) ver Die Bur fbeschein erdingen eau Ver igung fes schiedenen zul itas Co Nr. 200 ässigen tgelegt. nsume 4 nach Aus r Produc führungen 1994 (94 Artikel ts 9 sind in die Kon /9/EG) die Erf der Richtlinie Services Ge der Anl rmany üllung des Ra age Gm Verwenduzeption und der den Bau grundlege tes der Europä bH bescheinig nden der Prü ng in explos t als isch von Ge fung sin ion räten undSicherheits- unden Gemeinscha Benannte Ste d in dem sgefährdeten (9) lle ft vom Gesundhe Schutz Ber vertrau Die gru system lichen Prü eichen gem ndl itsanforde 23. März en äß mung mit egenden Sic zur fbe run Anh richt 14T bestimmu gen herheits: H0437 ang II der Ric ngsgem für und Ge festgeleg htlinie. äße sundhe n Die Erg t. itsanforde ebnisse rungen EN 600 werden 79-0:2012 erfüllt dur ch Übere instimEN 600 EN 600 79-7:2007 79- 2:2014 . (3) ng (10) (11) (12) Falls das die sich Zeichen ,,x'' hin ere Anw endung ter der Besche des Ge inigung Diese EG rätes in snumm -Baumust er steht, der Anl Geräte erprüfb age zu s wird auf escheinig dieser lung und gemäß Richtli besond Besche ung nie 94/ ere Bed das in inigung 9/EG. We bezieht sich Verkeh ingung hingew en für rbringe nur auf Die Ken iesen. n dieses itere Anforderu Kon nzeichnun Geräte ngen die zeption und g des Ge s. Bau ser Ric rätes mu htlinie gel des festge ss die folg legten ten für enden die He Angabe rsteln enthal ten: Nürnberg ATEX- mination xa Type E te a ic Certif umpPTFE-p r with e chamb gm ra h p ia d er chamb Pump EAR with 2 ions ct e n con Pump g k r ma in Ex 05 o m it R or ctors f Conne / cooling g heatin l) na io (opt cheinigu Fluidanschlüsse: 1 REA-Z-connection with stainless steel screwing and PTFE- / silicone insert 2 cylindrical PTFE-/silicone - Flex insert 3 RSVA- cutting ring connectors with PTFE adaptation 4 REA-P-connection with PEEKscrewing and PTFE-sealing ring and cone , 22.10. 201 5